Loading...
HomeMy WebLinkAboutWPO201300079 Inspection 2016-01-11COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville. Virainia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 EROSION CONTROL RE -INSPECTION INVOICE DATE: 1/12/2016 INVOICE TO: 511 Street Ventures, LLC 5 SW Broad St. Suite B Fairburn, GA 30213 Avon Holding, LLC 455 Second Street SE 5th Floor Charlottesville, VA 22902 RE: Notice To Comply 5th Street Station WP0201300079 DATE OF RE -INSPECTION: November 9, 2015 RE -INSPECTION FEE: $250.00 By February 12, 2015 you should forward the re -inspection fee of $250.00 to continue your project. To pay the re -inspection fee, please send a check payable to the County of Albemarle to my attention along with the enclosed copy of this invoice. If you should have any questions, please do not hesitate to contact me. Sincerely Todd Shifflett Engineering Division TS/ Enclosure COUNTY OF ALBEMARLE 5 l� - Iml Department of Community Development 401 McIntire Road v Charlottesville, Virginia 22902 NOTICE TO COMPLY Hand delivered Project: WPO Ze IS UOO C� i �J�? Date: a u Z Under section 17-900 of the Albemarle County Code, this is your NOTICE TO COMPLY with the requirements of the VSMP Permit for the referenced project and to immediately take corrective measures that address the deficiencies on this property. The specific deficiencies are circled below: Mud on road Shovel and sweep all mud and dirt from the road. Install adequate wash - rack and construction entrance for cleaning. easures not instar Items not been installed per the approved plan, or have been removed. Install them, or obtain a plan amendment. Measures failing Measures have failed more than once. Build larger, more effective ones, or amend the plan to better protect the site. Site abandoned and repairs needed The site is not stabilized and erosion is occurring. Repair all measures and stabilize. No inlet protection Inlet protection has not been installed. Install inlet protection per the plans. Site does not m� atchplaw— - e site has deviated too much from the approved plan, or the -'� plan was not buildable. A plan amendment is required. SWPPP documents deficient Correct document deficiencies. P ution prevention practices not fo 'Install, maintain practices per SWPPP and CGP. `s out facilities not provided or u- s—e 1- ,Jnstall and/or properly use washout facilities per Unless subsequently amended in writing by thisffice, it is expected all of these corrective measures will be completed by: Date: l Caxri Re -inspection of this notice to verify corrective measures will incur a $250 fee (17-207/8, $150 for SF). Failure to take effective County Inspector Signature: Receipt Signature: se-jE A -r ke-D o�WcNbu -m Work Order upon re -inspection. Addendum 1 9' Street Station AVON STREET SIDE: October 21, 2015 Many silt savers along roadway are damaged; repair/replace. - Stabilize perimeter slope (slope on NE side of site is denuded). - Pond above walls C and D needs to be mucked out (same condition as post storms). - Channel that leads into pond needs to be re -worked. Area behind trash pile (directly above C&D area near VDOT right-of-way), needs cleanup. Silt fence was completely overwhelmed from storms. - New plan shows diversions above wall C&D area on both sides of the culvert. Corrective measures need to be installed to divert as much runoff from upslope areas away from culvert and stream area. - Add stone to creek crossing. Other protective measures may be needed to protect denuded areas from entering stream. - Add concrete washout before concrete work begins. DEVELOPMENT SIDE: - Stabilize perimeter areas. - Add trap to washrack, and make functional. Muck out, increase capacity of sediment basin I (wet storage area especially), so that it has the capacity to handle the drainage area. Add/maintenance the diversions that lead into SBI and stabilize. Sediment basin 2 is not fixed/built according to the plans. Area below wall B (on culvert side), has fill outside the limits of construction and needs silt fence. Sediment trap 7 (on new plan), needs to be installed per plan. Stabilize perimeter slopes behind/around M. Add silt fence along downstream side of culvert (there is an opening). Concrete washout needed.