Loading...
HomeMy WebLinkAboutSDP201400075 Correspondence 2014-11-26 Now ,ee0 t �;,e4 j Dominion 1110 Engineering 172 South Pantops Drive 1, Charlottesville,Charlottesville, VA 22911 � e (r► 434.979.8121 (p) acts 434.979.1681 (f) DominionEng.com November 26, 2014 Ms. Megan Yaniglos, ASLA Senior Planner Albemarle County Community Development Department Division of Current Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 RE: SDP-2014-057 and SUB2014-136 CASCADIA B11-3 Preliminary Plat and Initial Site Plan Dear Megan, Enclosed please find eight (8) sets of the Final Site Plan. The plans have been revised based on your comments on the dated September 30, 2014 in accordance with the following: PLANNING DIVISION APPROVAL OF DATED SEPTEMBER 30, 2014 A. INITIAL SITE PLAN (SDP201400057) 1. A site plan meeting all requirements of section 32.6 of Chapter 18 of the Code. RESPONSE: A site plan meeting these requirements is included with this submittal. 2. A landscape plan meeting the requirements of section 32.7.9 of Chapter 18 of the Code, including a tree conservation checklist. RESPONSE: A landscape plan meeting these requirements is included with this submittal. 3. A plat meeting all the requirements for final subdivision plats per the subdivision ordinance. RESPONSE: A plat meeting these requirements will be submitted before final approval. 4. [14-302(B)(5)] Zoning classification. Provide the ZMA number on the notes sheet (ZMA2002-004) RESPONSE: The ZMA number is provided on SP2. �s ce ocs ��e-► Dominion Engineering 172 South Pantops Drive , Charlottesville, VA 22911 �; oe _ L 434.979.8121 (p) 'le s 434.979.1681 (f) DominionEng.com 5. [14-401] Double Frontage Lots. An exception is needed for lots 30-37 for double frontage. Additional planting will also be required. "Double frontage lots for single family detached and attached residential uses are prohibited. The prohibition of double frontage lots may be varied or excepted by the agent as provided in section 14-203.1. Double frontage lots shall be screened as provided in section 14-419." RESPONSE: An exception has been requested for lots 30-37. Additional plantings / screening has been provided for these lots as shown on the landscape plan. 6. Will this section be phased? If so, show the phasing lines RESPONSE: [32.5.2(c)] Phasing lines are provided on sheet SP5A of the site plan. 7. [Variation #5] The variation request for the garages did not include the elevation or details as stated. Provide those details for review. Also, as part of this variation, the front porches may need to be extended the full length of the house. RESPONSE: Elevations have been included with the variation requests. 8. Approval of the variation requests by the Board of Supervisors. Once the variation requests have been revised per these comments, resubmit so that they can be scheduled for the Board meeting. RESPONSE: Acknowledged. ENGINEERING DIVISION APPROVAL OF DATED SEPTEMBER 30, 2014 A. INITIAL SITE PLAN (SDP201400057) 1. Show matchlines on sheets. RESPONSE: Sheet key added to each sheet. 2 of 9 *41.r % C0 o15 c��� Dominion h • Engineering 172 South Pantops Drive Charlottesville, VA 22911 434.979.8121 (p) 9 e eps S 434.979.1681 (f) DominionEng.com 2. There are items from blocks 4-7 shown as existing on this plan, which means that this application will be approvable once the subdivision, site plan and wpo plan from blocks 4- 7 are approved. Please clarify if this is how you would like to proceed. Also, there is a new grading plan for lots along the proposed Delphi Lane extension and commercial bldg area. This area has changed since the approved WPO2013-32. Please address how you would like to proceed with coordination of that plan. For example, a sediment trap should be placed south of the proposed Cascadia Drive. What are revisions to the erosion control measures as the temporary conveyance channel is removed and Dephi Lane is constructed? RESPONSE: The developer would like to proceed in the manor that you described. The intent is for the sediment basins that were constructed under WPO 2013-00032 to remain in place during blocks 1-3 construction. Therefore, a sediment trap south of proposed Cascadia Drive is not required. Also, the temporary conveyance channel will be replaced with a storm sewer pipe system with inlet protection. 3. In conjunction with comment 2, the SWM Pond #2 is shown as existing. Under the new VSMP regulations, as-builts shall be provided for existing SWM facilities. Since the facility is not yet built, please clarify coordination of these plans. RESPONSE: As described in the response to comment#2 above, the intent is for Pond #2 to be in place as a sediment basin, and converted to a retention facility once total build out of all blocks is complete. Please refer to the E&SC and Stormwater Management Plan for Cascadia Blocks 1-3 for further detail on coordination of Pond #2. 4. There should be no disturbance within the SWM Pond #2 easement. It appears the layout of the commercial site shows disturbance within this easement. Please address. RESPONSE: The easements for Pond #2 have been revised. There is no longer disturbance from the commercial site within the easement. 5. The road plan shall be approved by VDOT. RESPONSE: Acknowledged. 6. Parking should be separated from entrances and street. Remove the parallel parking near the commercial bldg. One recommendation is to rotate the entire parking layout by 90 degrees and remove the choked entrance or flip the bldg and parking lot to change entrance location. RESPONSE: Per discussion in engineers meeting the design is permitted as is, with an adjustment of the entrance to allow for a curb to curb width of 24'. 7. I do not recommend the street ending as shown near lot 22. I recommend a radius of 200' 3 of 9 NOW .Oeeos Dominion c ' Engineering 172 South Pantops Drive Charlottesville, VA 22911 9 434.979.8121 (p) • o �� 9eQrs 434.979.1681 (f) S DominionEng.com to avoid this stub out. RESPONSE: VDOT has approved the current design. The stub out is less than 150' in length and serves 3 lots. 8. Show and label managed slopes. RESPONSE: Managed slopes are shown and ground cover specified on Landscape Plan. 9. All retaining walls on managed slopes should adhere to section 30.7.5[a] of Albemarle County Code. RESPONSE: Acknowledged. 10. Show design of retaining wall. RESPONSE: Retaining wall detail has been provided. 11. I recommend revising the road layout for lots 106-111 and remove turnarounds and stubouts. Show a 200' radius and connect the Knoll Lane to Delphi Lane. RESPONSE: A one way connection to Delphi Lane has been made and a radius of 100' has been provided per discussion with county engineers. 12. Provide drainage computations. RESPONSE: Drainage computations have been provided. A. PRELIMINARY PLAT(SuB201400136) 1. An approved and bonded road plan for blocks 1-3 will be required prior to the submittal of this plat. RESPONSE: Acknowledged. 2. VSMP/WPO may need to be updated per comment 2 under the initial comment. RESPONSE: Acknowledged. ACSA APPROVAL TO INCLUDE DATED SEPTEMBER 30, 2014 1. Submit 3 copies of the final site plan directly to the ACSA (ATTN: Jeremy Lynn, P.E.) with water and sewer data sheets attached for construction review and approval. 4 of 9 e er ors �c` Dominion i • Engineering 172 South Pantops Drive Charlottesville, VA 22911 9 QtS I 434.979.8121 (p) Q�s 434.979.1681 (f) DominionEng.com RESPONSE: Required plans and data sheets have been included. 2. Lots 112-120 appear to share a private foresee main. The ACSA does not allow shared private force mains or laterals. RESPONSE: Sanitary sewer has been redesigned to provide individual force main laterals. 3. Include utility profile views (including the existing 8" sanitary sewer). RESPONSE: All sanitary sewer profiles have been included. E911 APPROVAL TO INCLUDE DATED SEPTEMBER 30, 2014 1. The road names, 'Village Drive' and 'Meadow Lane' are not acceptable road names currently. The road name of'Village Drive' should remain the same as 'Delphi Drive' because it is the logical extension of the existing 'Delphi Drive'. The name 'Meadow' has been used five or more times to begin a road name and is unacceptable. The other road names found on the plan ('Knoll Lane', 'Cascadia Drive', 'Delphi Lane', and 'Delphi Drive') are all acceptable road names. The applicant should contact this office with a list of three (3) proposed replacement names for 'Meadow Lane'. RESPONSE: The site plan has been revised. Village Drive has been renamed Delphi Drive, and Meadow Lane has been renamed Marietta Drive. FIRE & RESCUE TO INCLUDE DATED SEPTEMBER 30, 2014 1. Streets shall provide a 20 ft unobstructed travelway for fire access. Please mark streets "No Parking Fire Lane" to ensure 20 ft travelway. RESPONSE: The site plan has been revised to include "No Parking" signage. ARB APPROVAL TO INCLUDE DATED SEPTEMBER 30, 2014 1. Regarding requirements to satisfy the design guidelines as per§ 18-30.6.4(2), (3) and (5): o Provide large shade trees parallel to all interior roads, 40' on center, and 2'/2' caliper at planting. Shift pipes and utilities to accommodate the required trees. o Provide 21/2" caliper perimeter parking lot trees for the commercial building in Block 1. Provide a quantity of trees equivalent to 40' on center, coordinated with the entry park trees and the retaining wall. 5 of 9 Is �� Dominion °'y 740 ■. Engineering 172 South Pantops Drive Charlottesville,VA 22911 �s 2\ , 434.979.8121 (p) 9, ens IJ 434.979.1681 (f) P^S DominionEng.com RESPONSE: These guidelines have been met and shown in the Landscape plan. 2. regarding recommendations on the plan as it relates to the guidelines: o None. 3. Regarding recommended conditions of initial plan approval: A Certificate of Appropriateness is required prior to final site plan approval. Your next ARB submittal should include architectural designs and all final review checklist items, and should address the following comments: 1. Note that a "back of building" appearance will not be appropriate for any buildings visible from the EC. RESPONSE: Substantial screening has been provided to limit the visibility of the backs of houses from Route 20. Sections showing lines of sight from Route 20 will be provided with the ARB submission. 2. Provide a site section taken through the EC, the commercial building, and the residential units above. RESPONSE: Sections showing lines of sight from Route 20 will be provided with the ARB submission. 3. Include a dumpster screen detail in the plan. Identify the material of the screen on the plan. Coordinate the screen material with the building material. RESPONSE: Final design of commercial building and dumpster screen to be provided with separate ARB submittal. 4. Add the mechanical equipment note to the plan. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." RESPONSE: Note added to sheet SP2 in the Site Plan. 5. If lighting is proposed, provide a complete lighting plan for review. RESPONSE: Lighting is not proposed. Note added to SP2 that reads "All light fixtures shall be 3,000 lumens or less. 6. Revise the site plan to show the approved frontage planting for Blocks 4-7. RESPONSE: All proposed and existing plantings are shown on the Landscape Plan. 7. Revise the regular row of shrubs west of stormwater pond #1 to a mix of shrubs in an irregular layout consistent with the approved planting to the north. 6 of 9 Nurse Os s o c `e Dominion Engineering 172 South Pantops Drive Charlottesville, VA 22911 � �• '�e 434.979.8121 (p) 9'"ps s 434.979.1681 (f) DominionEng.com RESPONSE: Note added to sheet SP2 in the Site Plan. 8. Add landscaping at the southwest corner and east end of stormwater pond #1, consistent with the approved planting to the north, to blend this end of the frontage with the area to the north. RESPONSE: Plantings shown on landscape plan. 9. Provide large shade trees parallel to all interior roads, 40' on center, 2'/2" caliper at planting. Shift pipes and utilities to accommodate these trees. RESPONSE: Street trees provided. Utilities were designed to maximize available planting areas. 10. Provide 2'/2" caliper perimeter parking lot trees for the commercial building in Block 1. Provide a quantity of trees equivalent to 40' on center, coordinated with the entry park trees and the retaining wall. RESPONSE: Parking lot plantings provided. 11. Revise the plan to show the trees in the back yards of lots 22-29 on the entry park side of the property line. RESPONSE: Plantings shown on landscape plan. 12. Add the standard plant health note to the plan. "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." RESPONSE: Note added to landscape plan. 13. At the east end of stormwater management pond #1, round contours with a ten foot minimum radius where they meet the adjacent condition. RESPONSE: Contours have been rounded. 14. Indicate on the plan the material and color proposed for the retaining wall. Terrace walls over 6' tall. Use landscaping to soften the visual impacts of the wall. RESPONSE: Redi-Rock, interlocking concrete block is being proposed with ledgestone rock finish in a natural stone color. Typical retaining wall details and a photograph is provided in the Site Plan on sheet SP33. Plantings are proposed along all retaining walls 7 of 9 el IWO Cea°‘5 rag Dominion °'y • Engineering 172 South Pantops Drive � Charlottesville,VA 22911 �� � X11! 434.979.8121 (p) m et s 434.979.1681 (f) Q�S DominionEng.com to integrate the structures into the site and reduce their massing. Walls are only required to be terraced if they are constructed on managed slopes. 15. Include a conservation checklist in the plan. Show tree protection fencing. RESPONSE: Tree protection fencing is shown in the Erosion and Sediment Control and Stormwater Management Plan. The conservation checklist has been provided on sheet SP1 of the site plan. 4. Regarding conditions to be satisfied prior to issuance of a grading permit: o Include a conservation checklist in the plan. Show tree protection fencing. RESPONSE: Conservation checklist provided. Tree protection fencing is shown in the Erosion and Sediment Control and Stormwater Management Plan. FIRE & RESCUE TO INCLUDE DATED SEPTEMBER 30, 2014 1. The typical section for Meadow Lane is labeled as Meadow Drive. RESPONSE: Meadow Lane has been renamed to Marietta Drive. The road section has been updated to show the correct name. 2. The typical sections for the streets should be identified as either providing on-street parking or not. RESPONSE: A note regarding on-street parking has been added to the sections. 3. The pavement designs will need to be verified by pavement design calculations. RESPONSE: Pavement design calculations will be included with final submittal. 4. The proposed entrance to the commercial lot 120 does not appear to comply with the commercial entrance design standards as identified in Appendix F of the Road Design Manual. RESPONSE: The entrance to lot 120 has been widened to 24' curb to curb in order to comply, per discussion with VDOT engineer. 5. Can storm manhole 5 be replaced with a drop inlet and structure 6 eliminated? RESPONSE: This revision can not be made. The driveway for Lot 119 and the intersection radius does not allow enough room for an inlet to be placed. 8 of 9 `wr S ee s 0,4 Dominion v h ' Engineering 172 South Pantops Drive Charlottesville, VA 22911 9\\ 0. "; o 434.979.8121 (p) 9'Q�S S 434.979.1681 (f)et DominionEng.com 6. Some of the drop inlets appear to be graphically drawn as DI-2 structures. These structures should be DI-3 structures. RESPONSE: These are intended to be DI-2 structures. They are placed primarily along the west side of Marietta Drive to provide maximum separation from the existing sanitary sewer line as required by ACSA. 7. It appears that a section of storm sewer between structures 32 and 37 has been omitted from the plan. RESPONSE: Storm sewer from 32 to 37 is now included in plans. 8. A minimum of 90° should be maintained between the upstream and downstream storm sewer pipes at each structure. It appears that structure 17 should be shifted slightly to provide 90° at structure 16. RESPONSE: Storm sewer at that junction is currently at a 90.44 degree deflection. 9. As the road plans are developed and reviewed, there may be additional comments. Please contact Troy Austin at 434-589-5871 if you have questions or require additional information. INSPECTION APPROVAL TO INCLUDE DATED SEPTEMBER 30, 2014 1. Provide one van-accessible, barrier-free parking space, with associated curb cut, at the Commercial Office. RESPONSE: A van accessible spot and a CG-12 curb ramp have been provided. We trust the above adequately addresses your comments. We look forward to receipt of the approval letter for this project. Please let me know if you have any questions or require additional information. Very truly yours, Clint Shifflett, E.I.T. Attachments Cc: Charlie Armstrong Keith Lancaster 9 of 9 CS J. t,2 ov 4%Z4e4 Dominion 172 South Pantops Drive Engineering Charlottesville, VA 22911 434.979.8121 (p) °' e. 434.979.1681 (f) 9�ers s DominionEng.com March 13, 2015 Ms. Megan Yaniglos Albemarle County Community Development Department Division of Current Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 RE: Cascadia Subdivision Blocks 1-3- Comment-Response Letter- SDP-2014-075 Dear Megan, Enclosed please find ten (10) sets of the revised Site Plan. Please note that we have revised the Site Plan to address your comments dated January 9, 2015 in accordance with the following: 1. [32.6] Signature Panel. Revise the signature panel to not include "Current Development".That division no longer exists, "Planner" and "Engineer" will suffice. RESPONSE: Revised 2. [Sheet SP5] Remove the variance note on this sheet. Those variations were approved for Blocks 4-7. New variations have been received and are being processed. RESPONSE: Revised 3. Clarify if Phase 2 will include the entrance onto Rt. 20. It is a little unclear on the phasing plan. RESPONSE: The phasing plan has been revised to show a clearer picture of what is going on. The entrance to Route 20 is included with Phase 1. 4. [32.7.9]Street trees. There are many areas where street trees are not being provided. If the trees cannot be provided in the right of way because of conflicts with easement and utilities, provide them in a landscape easement on the lots. 5. [32.7.9] Street trees. There are many areas where street trees are spaced farther than 50 feet on center. Adjust areas so that additional trees can be provided. 4-5 RESPONSE: We have made every effort to provide as many street trees as we can. In areas where there are utility conflicts, we have provided trees in the front yard of the lots and included landscape easements. VDOT commented on the plans and are drawing a hard line with regards to trees within site distance triangles. In these areas there may be gaps but it is unavoidable. Page 1 of 2 'saw Nov ens ce 00 1, "�>e' Dominion 172 South Pantops Drive y Engineering Charlottesville, VA 22911 -;„. 434.979.8121 (p) , e 434.979.1681 (f) 9�e,s s DominionEng.com 6. [General] Lots 68 and 69 are not labeled on the landscape sheets. Add the labels. RESPONSE: Revised 7. [Proffer] Designate which lots/units will be affordable on the plans. RESPONSE: We have added "ADU" labels to lots/units that are designated Tfbidto Nb�e a fordable dwelling units. C\A) ` Ct.V tt ZI V^S, le ? ee 16 8. [Variation Requests] The variations are being reviewed and are tentatively set to go to the Board on February 11th. RESPONSE: Acknowledged. We trust the above adequately addresses your comments. Please let me know if you have any questions or require additional information. Very truly yours, Clint Shifflett, EIT Attachments Cc: Keith Lancaster Page 2 of 2 'vise s pee°<s (2,44 a" Dominion 172 South Pantops Drive °i y • Engineering Charlottesville, VA 22911 �,� 434.979.8121 (p) ,9 °Q� _ _ 434.979.1681 (f) e, s DominionEng.com March 13, 2015 Ms. Michelle Roberge Albemarle County Community Development Department Division of Current Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 RE: Cascadia Subdivision Blocks 1-3- Comment-Response Letter-SUB2014-00207/SDP2014-00075 Dear Michelle, Enclosed please find four(4) sets of the revised Final Road Plans and eight(8) sets of the revised Final Site Plan. Please note that we have revised the site plan to address your comments dated January 27, 2015 in accordance with the following: Site Plan I Road Plan 1)On sheet SP4,there should be a diversion from the scc to pond 2. RESPONSE: Revised 2)On SP4, show the remaining managed slopes. RESPONSE: The remaining manage slopes have been added to the plan. 3) Show dumpster pad detail. RESPONSE: Spot elevation have been added to the plan to ensure positive drainage. 4)There is a 6' wide min sidewalk requirement for sidewalk in front of bldg. Please dimension. RESPONSE: The sidewalk in front of the commercial building is 6'wide and has been labeled as such on sheet SP6. 5)The northern parallel parking in the commercial area will be difficult to maneuver. Please address. RESPONSE: The parking lot has been reconfigured and the northern parallel parking space has been removed. Page 1 of 6 <se < *sr Nue eo °4°e; ' Dominion 172 South Pantops Drive °/y � • Engineering Charlottesville, VA 22911 y\`\ 434.979.8121 (p) ,9?e�s_I_ 434.979.1681 (f) e,s DominionEng.com 6) Label CG-2 on commercial parking. Show detail. RESPONSE: Revised. 7) Relocate spot elevation for dumpster pad to be legible. The site shall be designed so that stormwater does not run through, and drains away from,areas where dumpsters are located in order to minimize the potential for contaminating stormwater runoff due to contact with solid waste. RESPONSE: Revised 7)Relocate spot elevation for dumpster pad to be legible. The site shall be designed so that stormwater does not run through, and drains away from, areas where dumpsters are located in order to minimize the potential for contaminating stormwater runoff due to contact with solid waste. RESPONSE: Revised 8) It appears another wall will be necessary behind lots 18 and 19 to avoid grading over sanitary sewer mh. However, it also appears the geogrid will extend beyond bldg foundations for lots 16-19. Please address. RESPONSE: We have proposed adjustments to the top elevations of these sanitary manholes. 9)The geogrid appears to extend beyond bldg foundation of lot 22. Please address. RESPONSE: The wall has been redesigned and approximate geogrid locations have been added to the plan where walls are in close proximity to buildings. 10)All retaining walls facing Rte 20 will require ARB approval. RESPONSE: Conditional approval has been granted by the ARB, with stipulations on wall height, terracing requirements and screening. The walls have been redesigned to meet this criteria. 11) Show a crosswalk at entrance of commercial area. RESPONSE: Revised. 12) Show low maintenance ground cover, not grass, for all areas with 2:1 slopes. See the following areas: Area near str 14C, slopes adjacent to stairs, north of lot 6 near retaining wall, near lot 22, near north of commercial bldg, within Park A, etc. This can be shown with landscaping plan. RESPONSE: The landscape plan now includes a note on each sheet that specifies low maintenance ground cover for all areas with slopes steeper than 3:1. To make it more clear,we have also added lables to the slopes that indicate if they are 2:1 or 3:1. Page 2 of 6 Nor Now' v5 ti, dots g44% Dominion 172 South Pantops Drive CD 4 • Engineering Charlottesville, VA 22911 6 d „/ 434.979.8121 (p) 434.979.1681 (f) 9°ems s DominionEng.com 13) It does not appear you are meeting Proffer 1 (G)and(H). Please verify and address. RESPONSE: The lots in question of been regarding in order to meet these proffers. 14) Show calcs for existing 7A and downstream stormsewer,where 43 ties into. Verify that existing 24” HDPE is adequate. Do the same for existing 5. RESPONSE: An adequate outfall analysis has been added to sheet SP21 that indicates the existing stormsewer is adequate for the additional run-off. 15) 15"pipes are the minimum requirement. Revise 12" stormsewer pipes. RESPONSE: Per our email conversation it is acceptable to have 12"stormsewer pipes if they are to be privately maintained. All proposed 12"stormsewer pipes shown on the plan are to be privately maintained and are covered by a private drainage easement. 16) 58A will be prone to clogging. How will it be constructed with the SCC?Also,the grate will not capture entire runoff and area is subject to erosion. Divert excess runoff to an adequate outlet. Can existing sediment trap be converted to a permanent BMP? Show access road to BMP. RESPONSE: Structure 58A has been redesigned to lie within a sump condition. We also ran a 10-Year storm analysis on this structure and provided the 10-Year water surface elevation on the plans. 17) Profile and calculations should match. Please address for downstream pipes after str 37, 36, 31 and 30. RESPONSE: Our calculations and/or profiles have been revised and now match. 18) Please show profile for 46A-46. RESPONSE: Profile 46A-46 has been added to the plan. 19) For str 32-31, show drainage easement on lot 59. RESPONSE: Revised 20) For str 14B-14 A, revise drainage easement to include pipes. RESPONSE: Revised. 21) For str 62-ex 5, show drainage easement. RESPONSE: Revised Page 3 of 6 '5 \C Alts C4 A°I' Dominion 172 South Pantops Drive 07 y '� • Engineering Charlottesville, VA 22911 Ami ■ 434.979.8121 tt °VW/ ► I 434.979.1681 (f) °ems s DominionEng.com 22)For str 9-ex 3, show drainage easement on lot 37. RESPONSE: Revised. 23) Show existing SWM easement and access easement for pond 1. RESPONSE: Revised. 24)Remove plantings on drainage easements. For example, see str 22-23. Verify for other locations. RESPONSE: All plantings have been removed from drainage easements. 25)Match Ex2 and Ex 3 downstream pipes with approved site plan from Blocks 4-7. Please verify they match. RESPONSE: As we discussed in our email correspondence,we have proposed a field revision to these structures for Blocks 4-7 in order match the proposed development in Blocks 1-3. The field revision has been sent to the contractor, county engineering and Jeremy Glode. 26) Show details for nyoplast dome grates. RESPONSE: Details have been added to sheet SP34. 27) Verify direction of flow change in each drainage structure is 90 degrees or greater: 48-46,45-44, 27A-26, 21-19, and 8A-7. RESPONSE: Flow arrows are shown on plan. 28) Show all DI structure details. RESPONSE: All DI structure details have been added to the plan. 29) It appears you are showing grinder pumps. Please show a private onsite central sewerage system for those lots. Then it can be pumped to tie into the public sewer system. Please discuss with RESPONSE: The current layout remains as the ACSA will not permit an onsite central sewer system. Road Plan 30) Per proffer 2, VDOT approval is required for proposed 20' additional public R/W along the edge of existing Rte 20 right of way. The owner shall dedicate to address future potential improvements along Rte 20. RESPONSE: The current layout remains as the ACSA will not permit an onsite central sewer system. 31)The interconnection for Broadus Baptist Church is shown. The 30' wide easement is centered along the trail. If a future connection is to be made, how will an adequate driveway be built if the retaining wall from the Page 4 of 6 *ire 'woe 5 ,Aox 5 A�oe Dominion 172 South Pantops Drive • Engineering Charlottesville, VA 22911 4349798121 I � . . (p) ,�°o1 434.979.1681 (f) P� S DominionEng.com commercial building abuts the trail?Also, slope east of pond 2 will need to be regraded, but it is already at 2:1 slope. If a wall is built, it will be subject to ARB review. Please address. RESPONSE: The easement has been adjusted to be centered along the proposed trail, and wall redesigned to lie outside of the easement. The 30' easement should be sufficient in the unlikely event of a private driveway being constructed. 32) It appears Knoll Lane is proposed as a one way road since it cannot meet VDOT sight distance requirements for vehicles turning into Delphi Lane. I recommend ending Knoll Lane with a cul de sac and adding landscaping for screening. Also, increase road width to 24' wide with 2% cross slopes(typical VDOT cross-section)with no parking signs on both sides. Discuss with Fire Rescue. RESPONSE: Knoll lane has been redesigned to have a two-way movement. It is proposed that knoll lane be an Alley and retain its 20'width as the lots now front along Delphi Lane. 33) Please remove the perpendicular parking on Knoll Lane. RESPONSE: Revised. 34) If the subdivision plats will be phased, note the road plans will need to be delineated to match phasing plan with proper turnarounds. We have a policy that one road plan with appropriate title should correspond with subdivision plat phase. RESPONSE: Phasing has been provided and should allow for proper turnarounds where necessary. Phased road plans based off the shown phasing lines will be submitted after site plan approval if necessary. 35) Label all signs on road plan. RESPONSE: All signs have been labeled. 36) Show intersections within a road profile. Label elevation and station. RESPONSE: All intersection stations and elevations have been added to the road profiles. 37) Show sidewalk detail per VDOT standards. RESPONSE: A VDOT sidewalk detail has been added to sheet SP34A. Page 5 of 6 ts 'sire Nigro „e ors \` -r% Dominion 172 South Pantops Drive v y! • Engineering Charlottesville, VA 22911 0. i 434.979.8121 (p) ",9 Q� 434.979.1681 (f) ''e, S DominionEng.com 38)Road plans shall be approved by VDOT, Fire Rescue, and ACSA. RESPONSE: Acknowledged. We trust the above adequately addresses your comments. Please let me know if you have any questions or require additional information. Very truly yours, C Clint Shifflett, EIT Attachments Cc: Keith Lancaster Page 6 of 6 Nitre e5 oe ors Dominion 172 South Pantops Drive Engineering Charlottesville, VA 22911 434.979.8121 (p) "S>och 434.979.1681 (f) her e ss I� DominionEng.com March 13, 2015 Ms. Margaret Maliszewski Principal Planner Albemarle County Community Development Department Division of Current Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 RE: Cascadia Subdivision Blocks 1-3- Comment-Response Letter-ARB-2015-05 Dear Margaret, We have revised the Site Plan to address your approval conditions comments dated March 12, 2015 in accordance with the following: 1. Regarding the commercial building, staff shall work with the applicant to identify the building and site envelope to address landscaping, retaining walls, elevations, and building orientation. Retaining walls shall not exceed 6' in height. Building and site envelope approval shall include interim site concept plan prior to construction of new building. RESPONSE: An exhibit has been provided showing an interim site plan for the commercial building site and includes the building envelope area. 2. Add the standard window glass note to the architectural drawings: "Visible Light Transmittance (VLT) shall not drop below 40%. Visible Light Reflectance (VLR) shall not exceed 30%." RESPONSE: All architectural drawings shall include the aforementioned note. 3. Include a dumpster screen detail in the plan. Identify the material of the screen on the plan. Coordinate the screen material with the material of the commercial building. RESPONSE: A dumpster screen detail has been added to sheet SP33 of the site plan. 4. Add landscaping along the frontage at the southwest corner of the development, consistent with the approved planting to the north, to blend this end of the frontage with the area to the north. RESPONSE: Additional landscaping in this area has been provided. 5. Provide large shade trees parallel to all interior roads, 40' on center, 2W caliper at planting. Shift pipes and utilities to accommodate these trees. RESPONSE: Street trees have been provided in all areas where permitted. VDOT required us to remove multiple trees from the site distance triangles, and we have to maintain adequate separation from utilities. In areas where it is prohibitive to place street trees, we have proposed street trees behind the sidewalk within proposed landscape easements. Page 1 of 2 CS eeCS I Le Dominion 172 South Pantops Drive a 1r Engineering Charlottesville, VA 22911 0. 434.979.8121 (p) ss�o�,r 434.979.1681 (f) Hers s DominionEng.com 6. Adjust utilities to provide trees on both sides of the entrance road into the development from Rt. 20. RESPONSE: The commercial building has been moved +l-8' away from Cascadia drive, per our discussion in the ARB meeting, to provide a large planting strip. Street trees have been added to the landscape plan in this area. 7. Terrace portions of the retaining wall at the commercial building that are 6' tall or taller. Provide planting on the terraces. Provide the retaining wall details in the site plan for review. Indicate the block manufacturer, style and color of the block on the plans. RESPONSE: The retaining wall on the commercial building has been revised such that it does not exceed 6' in height. Terraced walls have been provided behind lots 22-26. Planting along the walls and a double row of evergreens along the corner of the wall has been provided as well. Retaining wall product information has been provided on sheet 34A and a color copy is attached to this comment response letter. 8. Submit for the review the E&S plan showing tree protection fencing. RESPONSE: An E&S plan with tree protection fencing has been submitted. 9. Add double row of evergreens at the corner of the retaining wall near Lot 22. RESPONSE: A double row of evergreens have been provided. We trust the above adequately addresses your comments. Please let me know if you have any questions or require additional information. Very truly yours, Clint Shifflett, EIT Attachments Cc: Keith Lancaster Page 2 of 2