Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SP201500012 Assessment - Groundwater 2015-02-16
Tier 3 Groundwater Assessment of Albemarle County Parcel#57-31A for rnw Mech um's Trestle, LLC 99 Bloomfield Rd Charlottesville, Virginia 22903 prepared by HydroGeo Environmental, LLC 1007 Montrose Avenue Charlottesville, Virginia 22902 `OOP Project#15-171 ... Issued: February 16, 2015 S�NOALTJ1off` .r. `NW U ERNEST W.RE..L , . �.- No.2801001974 rnest Beas , S, PG Geologist ,.. 0FSSI013 P"L `" Tier 3 Groundwater Assessment—Medium's Trestle, LLC HydroGeo Environmental, LLC ,r,. Crozet,Virginia February 16,2015 *rr goy Table of Contents Key Findings I 111101. 1.0 Introduction 2 "' 2.0 Site Overview 2 11► 3.0 Field Survey Summary 2 3.1 Site Layout 2 Am"ry.r — 3.2 Geologic Mapping 2 v" 3.3 Nearby Features of Interest 2 4.0 Hydrogeologic Assessment and Review 3 .r• 4.1 Hydrogeologic Setting 3 ma r 4.2 Bedrock Geology 4 4.3 Soils 4 law 4.4 Groundwater Flow,Recharge and Discharge 4 ..r 4.5 Existing Well Records 4 `ow 4.6 Groundwater Sensitivity and Contaminant Threats 5 rrr .r 5.0 Groundwater Management Plan 6 5.1 Contingency Plan 6 IOW VIM 6.0 Assessment of Well Drilling and Testing 6 .or 7.0 Summary 7 IMP 4•.'' Tier 3 Groundwater,4ssessment-A/echum's Trestle, LLC HydroGeo Environmental,LLC rrr Crozet,Virginia February 16,2015 411` Table of Contents (continued) TABLE Table 1: Nearby Well Data *.r �► LIST OF FIGURES Figure 1: Site Location Map .r Figure 2: Site Layout Map a.r Figure 3: Proposed Development Air Figure 4: Geologic Map Figure 5: Nearby Features of Interest qiw Figure 6: Shallow Groundwater Flow Map vow Figure 7: Deep Groundwater Flow Map Figure 8: Contaminant Sources VIM/ IOW Alf APPENDICES sur go" Appendix A: Web Soil Survey Report Appendix B: Well Completion Reports and Septic Records vow Appendix C: Environmental Data Resources Report Appendix D: VDH Well Site Approval Letter Appendix E: Soil Analytical Report °"'" Appendix F: References rr• r.. AMY vrw *Ur 4.r ii VOW low Tier 3 Groundwater Assessment—Alechum s Trestle, LLC HydroGeo Environmental,LLC — Crozet,Virginia February 16,2015 ,M, Key Findings �► Albemarle County hydrogeologic unit: Lynchburg Group - Mechums River Formation (IV) a.. Groundwater availability zone: Class 3 (highest groundwater availability) �.. Hydrogeologic conditions favorable to proposed use? Yes. Site withingroundwater sensitivity zone? No. �•• Groundwater flow pattern: Groundwater recharge areas include vegetated land onsite and 111' undeveloped, permeable areas within the Mechums River and Lickinghole Creek watersheds, located upgradient of the Site; groundwater discharge areas occur along the Lickinghole Creek vs, and Mechums River streambeds; general groundwater flow direction is assumed to be influenced low by topography and likely flows east-northeast,the same direction as local surface water bodies. mow Contamination threats on record: None. Additional contaminant threats observed in field reconnaissance? None. Impacts of proposed use on existing users: Groundwater availability onsite should be adequate y'' for proposed use without affecting existing users offsite. vIlliv BMP recommendations: Maintain vegetated stream buffer as much as possible during .. development; implement runoff-neutral site plans insofar as practicable. IOW +.r .• NNW W Tier 3 Groundwater Assessment— Vechum's Trestle, LLC HydroGeo Environmental,LLC 40. Crozet,Virginia February 16,2015 `o' 1.0 Introduction This Tier 3 Groundwater Assessment Report(Tier 3)was prepared by HydroGeo Environmental, LLC (HydroGeo) for Mechum's Trestle, LLC (Mechum's Trestle). Mechum's Trestle is 1111• proposing to use groundwater supply for their planned project in western Albemarle County. The estimated water use for this development amounts to 5,000 gallons per day, or approximately 3.5 gallons per minute (gpm). The purpose of this report is to provide a professional assessment of the potential groundwater resources in the vicinity of the proposed development. This Tier 3 Report was completed in accordance with the requirements outlined in Section I.2.D of the Albemarle County Design Standards Manual for Engineering. .r. 2.0 Site Overview gay The proposed development is located to the east of the town of Crozet, Virginia, at the — intersection of Routes 240 and 250 (Figure 1). The approximately 1.4-acre property is identified as Albemarle County Parcel #57-31 A (the "Site"). The Site is zoned C l commercial and all adjacent parcels are zoned rural. Land use in the immediate vicinity of the site includes light Air agriculture and rural residential. A wooded buffer exists onsite between a central open area and Lickinghole Creek, which borders the Site to the west and north (Figure 2). Site elevation is approximately 500 feet above mean sea level (amsl). The proposed development design is depicted on Figure 3 (attached). 3.0 Field Survey Summary HydroGeo conducted site reconnaissance visits on January 19 and February 11, 2015. Site visits _ ' included geologic mapping activities, verification of n ea __rb ~w ell and se P tic locations, and visual inspections for hydrologic features, potential contaminant sources, and Site layout. 3.1 Site Layout The Site consists of an approximately 0.5-acre open area, the majority of which appears to be i`"` comprised of a gravel surface. One (1) abandoned structure was observed in the eastern area of - the Site. Two inactive wells were located during site reconnaissance activities. Site topography v,, is generally flat, but slopes downward along the vegetated edges toward Lickinghole creek to the north and west. (See Figure 2 for Site layout) 3.2 Geologic Mapping Based on field observations, Site geology consists of meta-sedimentary rocks (see section 4.2 for details). No outcrops were observed onsite; however, general orientation of the bedrock in the 1111► Site vicinity (based on nearby outcrops) is along a northeast-southwest strike, with a relatively vo, steep dip to the east-southeast (Figure 4). 'OW 3.3 Nearby Features of Interest 40. Precise residential well and septic locations on nearby parcels were difficult to pinpoint during site reconnaissance so-for the purposes of this assessment, most well and septic locations are `"' inferred based on the presence of homes. Two (2) springs across Lickinghole creek to the north �.► were observed and an aboveground storage tank (AST) with unknown contents was observed across a topographic ridge approximately 600-feet to the southwest of the site. No contaminant 110, threats were identified during field reconnaissance activities. See Figure 5 for nearby features of — interest identified during Site reconnaissance, records review, and GIS mapping activities. Mir �• 2 11. `'r` Tier 3 Groundwater Assessment- Alechum's Trestle, LLC HydroGeo Environmental,LLC ivy Crozet,Virginia February 16,2015 "w 4.0 Hydrogeologic Assessment and Review 4.1 Hydrogeologic Setting 11. The Site lies within the Blue Ridge Physiographic Province, a region dominated by fractured — bedrock aquifer systems. The hydrogeology of the Site groundwater system consists of a mantle vs,, of soils and saprolite (regolith, or overburden) overlying fractured metamorphic bedrock. The porous regolith provides groundwater storage for the underlying bedrock fracture network. ""` Unlike regolith, the bedrock in the Blue Ridge province has minimal primary porosity, so deeper 11, groundwater flow relies largely on the secondary porosity provided by the interconnected �,, bedrock fracture network: 1111 `�. ` •. -s. As" f� Pj s.- -s. `•�1 \ — .> i -•-'t7 t -,-.as� `. Ass. Air• (Heath,1980) .r Standard practice for development of water supply wells involves drilling into water bearing °— zones in the fractured bedrock and sealing off the overlying regolith with a solid well casing. 11,, Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures: 11r Vii ` " „" 'sit< _ .iio \ ' I I 6Fl. 111W 1_. _ .. _- » ,r (LeGrand, 1988) — A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture ., occurrence and density depends on a number of factors including specific location, rock type, 11W and site-specific geologic conditions. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long- .", term groundwater withdrawals. "W 3 may Aw Tier 3 Groundwater Assessment—Mechum's Trestle, LLC HydroGeo Environmental,LLC .r Crozet,Virginia February 16,2015 r 4.2 Bedrock Geology Certain rock units in the County are known to possess more favorable characteristics for the development of groundwater resources than others. A 2003 study completed by ENSAT Corporation ranked different rock units across Albemarle County based on their potential as groundwater resources. Factors such as degree of bedrock fracturing, overburden thickness, and ,,,,, saprolite permeability were considered in determining the relative groundwater availability potential of different units. According to 1:500,000 scale state geologic mapping (Virginia Division of Mineral Resources, 1993), field observations, and the Albemarle County Hydrogeologic Assessment Summary Report (ENSAT Corporation, 2003), the Site is underlain by the Mechums River Formation, a member of the Lynchburg Group (Hydrogeologic Unit IV). The unit consists of meta-sedimentary rocks of Proterozoic age and is ranked in Hydrogeologic may Class 3, indicating highest relative groundwater availability potential in the County. See r• Figure 4 for a graphic depiction of bedrock geology in the Site vicinity. Alkw 4.3 Soils According to National Resource Conservation Service (NRCS) soils mapping, the site is underlain by soils of the Toccoa series. Toccoa soils are comprised of alluvium and are reported v„ to be deep and very well-drained. A soils report of the Site and surrounding area, generated by the NRCS Web Soil Survey tool, is included in Appendix A. Based on an existing onsite well log (Appendix B), Site overburden is approximately 45-feet thick, suggesting favorable imy conditions for long-term sustainable groundwater withdrawals. 4.4 Groundwater Flow, Recharge and Discharge 41" The general groundwater flow direction in the vicinity of the Site is assumed to be influenced by .. topography. Shallow, localized groundwater flow within the overburden is interpreted to follow a pattern similar to that shown on Figure 6. Groundwater flow on a more regional scale, more representative of net flow through the deeper bedrock fracture network, is interpreted to follow a pattern similar to that shown in Figure 7. General groundwater flow in the vicinity of the site e..� likely follows a net east-northeast direction: the same direction as local surface water flow. 9.. Groundwater recharge areas include vegetated land onsite and undeveloped, permeable areas within the Mechum's River and Lickinghole Creek watersheds, located upgradient of the Site. Amy- Groundwater discharge areas occur along the Lickinghole Creek and Mechum's River streambeds to the north and east of the Site. 4.5 Existing Well Records ®,,,, On January 15, 2015, HydroGeo submitted a request to the Environmental Health (EH) division of the Charlottesville/Albemarle Health Department for well and septic records from the Site and from parcels located within a 1,000-foot radius of the Site. The EH search did not produce any records within the 1,000-foot search radius. HydroGeo submitted a follow-up request for well and septic records from sixteen (16) additional parcels located in the same hydrogeologic unit nearby (within 1/2-mile of the Site). The additional EH records search returned six (6) well completion reports. To contribute to this component of the Tier 3 Assessment, Mechum's Trestle provided a well completion report for an abandoned onsite well. All well and septic records referenced herein are included in Appendix B. Table 1 provides a summary of pertinent information obtained from the well records search. 4 NNW .r. mar Tier 3 Groundwater Assessment—A>echum's Trestle, LLC HydroGeo Environmental,LLC Crozet,Virginia February 16,2015 41" Table 1: Nearby Well Data Total Depth Depth to Bedrock Yield — (ft) ( ) (gam) 285 34 4 150 76 75 r„► 305 13 7 Nearby wells in same 205 50 3 hydro Bolo is unit as Site. glow 205 30 10 g g IOW 405 29 0.5 422 45 4.5 — 400* ND 0.5* ,} Onsite well data. """ Average Values: 297 39.6 13 nrr *Estimated values for inactive well on Site. values based on verbal communication with a local well driller who tested,but did not drill the well 11W ND no data Of the nearby well records obtained, total depth ranges from 150 to 422 feet below ground surface (bgs), overburden thickness ranges from 13 to 76 feet bgs, and yield ranges from 0.5 to Air 75 gallons per minute (gpm). Average well depth is 297 feet, average overburden thickness is 39.6 feet, and average yield is 13 gpm. Air 4.6 Groundwater Sensitivity and Contaminant Threats Based on an Environmental Data Records (EDR) review (Appendix C), reviews of Virginia Department of Environmental Quality (VADEQ) and Albemarle County online GIS mapping, and observations made during field reconnaissance, the Site does not appear to be located in 11111F an area of groundwater sensitivity. Two flow-though septic tanks are known to exist onsite (Figures 2 and 3). The user should — adhere to appropriate setbacks from these features as required by the Virginia Department of Health (VDH) regarding location of a new supply well onsite (see Appendix D: VDH Well Site Approval Letter). There were no open pollution complaint cases or toxic releases identified within the ''A mile EDR search radius. The closest open pollution complaint case is located approximately 0.8 miles downgradient of the Site and does not appear to pose a threat to Site groundwater quality. Figure 8 presents a graphic depiction of all historic Leaky Underground Storage Tank (LUST) cases within approximately one mile of the Site. 2,000-foot buffers around each LUST site are —`41111v shown in the figure. Figure 8 illustrates that the 1,200-foot search radius from the center of the Site (which encompasses the required 1,000-foot search radius from property boundaries) does not encounter any of the 2,000-foot LUST buffers. ,.,. At the request of VDH, Mechum's Trestle completed soil sampling in July 2013 to investigate for the presence of pesticide contamination resulting from potential termiticide applications on and around the abandoned Site building. Samples were collected by Mechum's Trestle at locations and depths specified by VDH. Soil samples were analyzed by TestAmerica Pittsburgh Air for organochlorine and organophosophorous pesticides via EPA methods 8081A and 8141A, respectively. No potential contaminants were detected and no environmental impacts were Air identified. Laboratory analytical results from this investigation are included in Appendix E. loy - 5 `r NOW %` Tier 3 Groundwater Assessment—Alechum's Trestle, LLC HydroGeo Environmental,LLC „i,. Crozet,Virginia February 16,2015 5.0 Groundwater Management Plan The proposed development will attempt to minimize degradation of groundwater recharge, and groundwater and surface water quality by preservinexistin.g vegetation where practicable and by implementing stormwater strategies to minimize offsite runoff. The development plan inclu`8es'standard stormwater Best Management Practices and sediment and erosion control measures. Depending on the final location of the future Site water supply well, a wellhead protection plan may be developed to protect groundwater quality. 5.1 Contingency Plan Based on this assessment, the Site is capable of producing sufficient groundwater yields to meet .., the proposed usage requirements; however, actual yield of the future onsite supply well cannot be known until the well is drilled. Based on actual yield of a new drilled well, a groundwater 4111/ pumping and management plan may be developed to meet the instantaneous demand of the proposed onsite water use. If a newly drilled Site well does not produce sufficient yield to meet the user's demands, hydraulic fracturing may be implemented to increase the yield. If well yield is still insufficient after hydraulic fracturing, a supplemental well may be drilled to augment the onsite groundwater supply. 4110' The new Site well should be constructed to meet Virginia Department of Health (VDH) low standards and wellhead protection measures should be implemented to prevent the well from becoming contaminated in the event of a spill or release. If the well were to become vow contaminated at any point in the future, the incident should be reported to VADEQ and a detailed environmental assessment characterizing the nature and extent of the contamination should be Ilr conducted by a Virginia Certified Professional Geologist. Depending on the site characterization results, groundwater remediation may be implemented to mitigate any contamination and a new well could be designed and constructed to extract clean groundwater from unimpacted water v"` bearing zones in the Site aquifer. 6.0 Assessment of Well Drilling and Testing Based on this study, the Site lies in an area capable of producing groundwater yields sufficient to meet the demands of the proposed Mechum's Trestle development; however, the actual yield of the future onsite supply well cannot be known until the well is drilled. This Tier 3 study identified details regarding two (2) inactive Site wells, the yields being 4.5 and 0.5 gpm. As - discussed in section 4.1, the performance of the new well will depend largely on the borehole encountering sufficiently interconnected bedrock fractures. The new supply well should be logged by a Virginia Certified Professional Geologist, so that 41111. changes in rock type and indications of fracture occurrence and density can be noted. These details may influence the total depth of the new supply well, which could end up being drilled much deeper than any of the existing wells discussed in this study. .., After the new Site well is constructed to meet the public supply well construction requirements of the VDH Office of Drinking Water (VDH-ODW), a pumping test should be implemented to determine sustainable yield of the well. Pumping rate, duration, and specific design of the ""'` pumping test should be based on VDH-ODW requirements, well yield and other subsurface characteristics determined at the time of drilling. Groundwater samples should be collected at the time of the pumping test to be analyzed for chemical, physical, bacteriological, and 6 goy MEW NOW g`` Tier 3 Groundwater Assessment—A9echu n's Trestle. LLC HydroGeo Environmental,LLC mar Crozet,Virginia February 16,2015 radiological parameters as required by VDH-ODW. After well development and permanent v" pump installation, the well should be disinfected via standard methods (this is usually performed �.• by the driller)to eliminate the presence of any bacterial contamination. voy 7.0 Summary law This Tier 3 Groundwater Assessment was prepared by HydroGeo Environmental for Mechum's Trestle's proposed development on a 1.4-acre parcel in western Albemarle County identified as Parcel #57-31A. Estimated water use demands for the proposed development amount to 5,000 gallons per day, which equates to 3.5 gpm. Based on this study, the site aquifer is capable of producing well yields sufficient to meet this projected demand. The Site is located in the highest ranked hydrogeologic unit for relative groundwater availability; however, actual yield of a newly qa` drilled supply well will not be known until the well has been drilled. The Site does not appear to iew be located in a groundwater sensitivity zone, no contamination threats were identified in this ,�, assessment, and the proposed use is not expected to affect existing users offsite. IMF VIP AS 7 vrr ®.r NNW "' Figures r.r NNW r.► r.. Mir .r VOW gay iii -_ j V 0 N N Q;ii .,—m cn J J � U® o co 0 .c13 E 0 o — C N u C L K >® z I— N •� d m C Q U ;0 C • O`U O d O CD — w a m V O U •o °0 2 W G CO O VW (a f > ? ' 'R l . , . r t ' � • 1 ) j • : — 'tr r 1 s.,. J , • j • S r , -14 L • �--- F _ F • _ 3 ti ` v 1 ._ � F L Nile { a { r - <it �. `fir .`. c y u v_ �� y -y h • :t :ThI . 'ter f ■ `, I ) 1 ■ \� � � 4 v! var [410 Lo CV aS N = > is o o 0 J c o /� r. w c2 0- N c (1) .m O CO 4( cn g 5 O 2 L cu _ 4 Y` E° Q) > a � , - N ¢ 3 , W i a ` _ U o a>1 - • CO Co rn V < E U O o • Ai C • CO O • I • ow / • o U / Z • / Q U / • I / • // • / a' i / > w I • C Q I /CD • I • I / • / • - • 4 / • I � • / 1111t • /i,, / • /I • __ / • • I. • I • • • • \r V 4 T I NOY rn ? w s up) d!iiig it a s � ..- 1 ,,,-• `i 4 /�� / A - �� tillW ` W j ;/ � ; 1 1 i �r� , \'''',."2 t"1 r ( 1 • xi a .±„ is 1a ' j I J .M'/b t i-44,..2 / �'y� 'T .:' d ! I � • 4 �F 3 .�l�1 W�R w.b. iir 1 i f, l' Ilk A,14r,,...4„,... .p-_-_-- _ Is tw i ,�Fe At s ifX • � / r r'el _ e 11%1 a a a I FP a' / r/ t, i `0 l ; !` i • l I e_ �� Y, ,. --;. / ? 1!a r 1. , 'NV,'.- r ,-------ci „, ,„ t • ,� y \ � l� i = g a. \ t ! ' \ ti / r C9 • \ ,yam w4*ua I CI 5 V, '� �c • \\ �a `t1 - `Na3:::,• ;`,;.7..,_2,,".‘"„T,„pH�M s�� I ♦ I.I e r ° • 1� r � • _ • 0. \ U }q\,qL,, N J 7 F s r ill!! O \ 1,41 I 11 -- 3 \ ~ U• c9 \ I �I m I� J 1 Vi\ k a m: - 1 • • / ' ,�/,V22S >`t C • / 1 N • - r i o d-r • O ! I • / I I r r ) r • • .r .ISO' +.r 1111W c 0 � yr o) d- E o O > Q N N J J > N f,1.2' Q� J m 43 -• C °o c. co m m u a N F C 0 �ai ai c a a m m a> > N aN> W c Q m 0? o_ o 0 a) N O w 0 m T N= U O elf✓ a N n Q n o) n U p ASV E a a' 3 O ° _ Allik E z err E r 3 N ` O 0 cr, i >- 0 4 m 40 low rt c w LU e N ® w L mai& u 0 w °n ,, • - . • i O s.11 • e T illbr E 4-, lZ • 0 0 Iti INF lr '1 Li viw Lo Vat 2 in III !ti J J N N U C ti o ) -y a c L p U •w o v a N N ¢ m o ¢ rn a a v co N N W Q U ■ ¢ S T2 2 N- ° 1- • Z fi ce G 0 z till 4 • fliP 3/404.1 • a 11 * `" 11 ❑ • $ a • • • i fi S • p. . 1 • x • • • or � � 9 ; 'ir -4' ,..' * 4t* liolot l'31101 4 ' i ,- t* tq, # gt ,i. r . • • • .r• VW LO aMir o j 5._'` to v d NW 6' a `o U J N J Z Iiir �7 -C L —as 0 U :11 07 c ca _ C as ? J O >a>p N= p i::‘;n¢ LL 3 4 U o 0 o N TT 0 2 L \1 Z o • III F Y • • • s �_ ��_� , S�j CMS �• i ■ • Q a_ . J. • -Y L. n • r _ �t • t J ,• •or i r u{r c - - ) �j' s i - VNIIIV [• .., ..,,..i._____..........,,,;.i.....__..i.,'...„..":...,,.....,,_, NW rr IMP NU" m b fl - - N d > J --o LL o o :::: °c U N rn o � °CNU Now ce 0 1\ • • ."-- ti N‘,.... i it za�� 4 •�— .e'; >y\ ii i l - _'• • tea • f , 4 , `4 � r ` • `... r may`•• . ::,..",,_,,, ,;„.. _ 41111 ,, - • - ! . , ,f • ► =t I ' . - N, •, -.• vair ib✓ lialf Aar • • CO LL � n y U co co ai o N j ( 4 .3 o J U-2. m . N E= C o C L - S P m LL j O U cl ti r co co E O W C Z = 3 g C U A � o C.) O E• O O rr.► U o _ o 0 Z • • w w L N. drO cn• " per' A• Z U • Paso° - . ,,, ,,Iiiir,_ . # i t ./ . VIO,' • • 4 1 111 V — ' • • • - i ' * • 1 • ,. it,,,,, • m c • .. f • J W I Ai is-y'�'pY'- ,. 1111/ , U • • • • • • • • • • • • • • • • • • • • • • • Appendix A • Web Soil Survey Report • • • • • • • • • • • • • or • • • • • iii two the z z N 008STZb OOLSTZb OO9STZb OOSSTZ4 OOt'STZ4 OO£STZ4 OOZSTZb OOTSTZ4 OOOSRb OO64TZ4 u7 M N O M„SZ BE o8L S M52 BE o8L 205 n d S N a R rI1M co VIP vo 0 °.' s � r 8 rte. ` ` N L�f n liair VW .ca N CD Ec N ,r h. o � �r cu .c N Q 8 v7 a n7t IOW I CC N Q N LL V d ✓ CO 8 ♦ v K> m g CO 8 it co 0 § Ln , �k i a g 8 7 14 g S G fV 1 - . , R �= 8 a xc , i� N 8 Air R I '4'4w g,.g a; N n— g y Z z U Q N M o 6Z bE o8C M„6Z,6E 08L OOLSTZ4 OO9STZ4 OOSSTZb MOSTZ4 00ESTZ17 00ZSTZ4 00ISTZ4 0005TZb 0064T Z1, OO8VIZb ASO z a z N I' M N .0✓ • • • • • 1.0 M • O O O C a ° O O V co C O N N W 7_ C O ) f co 0 C V 0 0 L6 a j N f0 N L3 .. U U N co a7 3 N co 0 I CD N N d CD • U ° C O O) M �O L 2 •° co O W 3 C_ 'O a3 00 0 N O ID L c O a) a) O a) c7 E Z m �� m °CL �)oo � 1 0 i 0 n • > N E E ■ a Eas ° 2 y cacco ° a Z� N• Za N � � Z N m 0 8 • Q y E o a w o �2 'nE O LO cod e)-0 va) o . U ° w m ._ oa . m N n L VN �5T o t• n L ° °ns • • rL O j •O O E U f0 3 N L ° > o c a>> Yo N ca C N U L O j O � coiwom 7 0 O U> 3 w p m m o C N N 0 `O C '' •°>° ai a. CO• LL z a) a)10 — N O O� � C O N C co 3 N a aN a 2 ° U EM C uj O O• L E 2,co a)• Ea 0. C o C C ▪L a) U) a) C) O L E ` N • O co a7• d Q o O ° o 0 a aooai y � y � `m f° - o° �� m m � �� • co co cmm ¢ a) °iv " E U'°rc ,on Y m > Oa as m 2 Q Z co -a .0 a) 0) ' N�c .c > L L di o 0)E oa t o o 5La cw a> >. m m m o h as p ca o oc m < - 2� w > o -° N� Qo = Cl) cu � >,E ° m E - c = c = c 1'2 co I ' O n t � 3�E c C n C y y U O y U C n a ( N m F- 5 w Env°, a. E U)> U 2 d 5 Q 0 F L° co co co o a N F coi o co lhor E lir ED 3 tea) 0 TA co • OF- = a) 4Ir c% — 27 E b E o N L 0 N m a O 0 ,all c m n O • a m co r m c co lL C co v w w ° O m o C C N = y c -O O f6 - ° m • ) m °. o p - N w O o .0 Z _ N 0 a ° aa) m t a w - c@ °' u) co 0 m co co > > 0 co a co o c D 2 _1 • c Q 0 7 o m °4. Z (� o € €> <i P w • W • Q °Q H T m C O c d a C p H .m E to • y m c c c O n a 3 o f6 0 ° a =a 3 m a w . o aa° m ▪ 0 m m m ° m d w r ° d c m T a ° ° U 2 2 2 i °3 E a w > > V as E2 m U N U C c > .0 m • : ¢` a ° ° c ° � ° o c icn co o m m v v � J J a c i c 0. 0 c ( V S C � y Q N C O R m • ' M TO 0 Z 0 e cl • • • • 4u r Near 44krf Soil Map-Albemarle County,Virginia Mechum's Trestle ASV aar "far Map Unit Legend aer Albemarle County,Virginia(VA003) Nr Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI Air 4D Ashe loam,15 to 25 percent 15.2 6.4% slopes lir 4E Ashe loam,25 to 45 percent 14.4 6.0% *ow slopes 41110, 10 Buncombe loamy sand 2.9 1 2% 'NOW 16 Chewacla silt loam 8.9 3 7% 21B Culpeper fine sandy loam,2 to 2.2 0.9% Aar 7 percent slopes war 21C Culpeper fine sandy loam,7 to 5.8 2.4% 15 percent slopes 22C3 Culpeper clay loam,7 to 15 4.9 2.1% VW percent slopes,severely eroded `r"` 36B Hayesville loam,2 to 7 percent 1.4 0.6% w+ slopes 36C Hayesville loam,7 to 15 percent 5.4 2.3% Nay slopes V,, 36D Hayesville loam, 15 to 25 8.2 3.4% percent slopes vow 37C3 Hayesville clay loam,7 to 15 18.7 7.8/ ®, percent slopes,severely eroded Nair 37D3 Hayesville clay loam, 15 to 25 0.7 0.3% percent slopes,severely As eroded - 39C Hazel loam,7 to 15 percent 15.7 6.6% slopes wr 39E Hazel loam,25 to 45 percent 26.5 11.1% VW slopes 42C3 Hiwassee clay loam,7 to 15 8.4 3.5% err percent slopes,severely eroded moo 55B McQueen loam,2 to 7 percent 6.4 2.7% w slopes *or 56B Meadowville loam,2 to 7 9.1 3.8% percent slopes vor 76 Riverview loam 14.8 6.2% vow 77 Riverview-Chewacla complex 15.1 6.3% mow 83 Toccoa fine sandy loam 48.9 20.5% ,4111, W Water 5.5 2.3% irr Totals for Area of Interest 238.9 100.0% +gar ler USDA Natural Resources Web Soil Survey 2/16/2015 'NW Conservation Service National Cooperative Soil Survey Page 3 of 3 wr ,ar afar ..r NNW r.. MOP Ir Appendix B ... Well Completion Reports and Septic Records r it NSI AllY w MOW sr aar 02/24/2012 16:32 5402899740 BURNER PAGE 01 ri",�i 7iw a ' l:llMMONWI. Al III (!l: VIIIt IINIA 15 711.1 0,000 WATER WELL COMI't,t 'I ION It1PUR I •IIWI M Nii air Stove Weser Control Board (Certification of CllFnpletfon/L'ounfy Permit) le". 0. Boa 11143 2111 North Mamllton St. SvveB Permu ler Richmond, V . 23230 County Permit "- ._ --_-"_—�-- r Certification of inspecting official Caunty/ rx ALBEMARLE This'well does does not air County/City Stamp meet code/1pw requirements. S, •VirgintaPlane Coordinates '41.; N •owner The Galerie Restaurant Date- '�r� E •Well Designation or Number — For Office,Use I Latitude Longitude Address C/o Don Nel son�`-- - N 1 :a, •' Char e - : le. VA 7229einnno I.D No.__ w Phone_ (804)823-5883. -- — subdivi.;on �' •TOpo. MAP No. — SCChon . ' •Elevation ft. •Dntling Contractor.-Bll1"ner We_11 DriIli,nq,_ Int- _ Block �- I •For mat ion Address P. O. Box 98 Lot__ -_ — wa. •Ltthology MCGashe s_v 11 z. VA 7284. c ass Well L. _ Il,a !•River Basin . Phone (703)289-9421 118 , II1A _---_ Hie. _ •Province Inc _IIID IIIE Intersection of 240 &-2.50ion! ot ,•Type Logs WELL LOCATION: (feet/rn es dnectlon o of Charlottesville @ CroZ t •Curti --- - � •�•--- ►t9s and feet/miles Idirectionl of s v•Water'Analysis Ill possible please include mop showing locotton marked) '-"`-"---'- "' ' •-" !•Aquifer Test • _ _ ___• ler '=+" "' ,'�- Date started 11/10/82 • Date completed 11/12182 Type rig A]_t__RO,La rte„ ar, Vii. ce, „':: t4-+ I,WELL OATA:.'New X' Reworked Deepened WNW •Total Pen ,.42 -t• tc 2.WATER DATA •Water temperature________•____ _ — OF •State water level lunoumoed level measured) ___20— _ ft. •Depth to bedrock 45 ft. ft •Slabll:zed measured urnp{np water level __ It, alit • :.:r. �,5 •HolrS'zelAlso include reamed tones) •Stabilized yield , gpm alter _ �_ • _hours •' ' • 10 inches Irom• Q ' to 52 it. Natural Flow: Yes No IIOw rate �_� me • 6 IrIChBS from 52 t0 "--' — gpm 472 It. Comment on Duality_ ___ ____sue to I . _- - -_To •Casing size(I.0.1 and materiel From To From r4 inches from 0_ to ___5.3__' h Froth__ To From To 4 USE DATA:per foot or waif thickness to Type of use Drinking ear • ' nking X Livestock Watering Inches from to _ ft Irr10J1i0n _FOpd processln Material — g__ , Housenoftl We -- Manufacturing Ere safety e Ieanrng Wt.per toot or wall thickness In. Recreation "— Aestnehc Cooling or netting .fir. • inches from to ft In a --"— Material ct,en Other _ -_ __ •TYDe of facility Domestic ,Public water suoply wow Wt.per toot or wall 'tuck Hess _ in. Public institution,. Farm _ Industry •'creen site and mesh for each Zone(where aUolrcablel Commercial__.Other rs` ar` •. inches from to ft pC�ldUrdni + 'Mesh Size Type S. PUMP 01ATA. TroeGoQ1 s__SflblllSfgSAi118 1 HP 7E 10.4 2 • depth 0Capacit lir • inches from to -_ft •Imak! y. at heed 6.WELLHEAD: Typt well StAi liar. *Mesh size Type V-� - �, -- ^--- Pressure rank . gal • LoC ' metes from _ — ttsrr •MMh site TYDe to — "ft Sairtule tap„- Measurement Port _ Well vent -- _ Pressure relt_f waive oar • inches from to ft Gate valve' P --"— Ghee valve'when reslu.redl *Mesh size Type '--- Clecrncal A� +err °Gravel pack yr sconncct lw.tch on power supply 7,OISINFECTION. ell disinfected *From to _ ft, yes no VW Date __ . D,SinIeCl'mt used •From _ CO It Amount ____ .HOu rs used sir •G►out 8. ABANDONMENT !where apt:the ble) •yes _no_ X -— •From 0 to So If . Type Cement Casing puncd yea se •Prom to ft. Type --_ ^O --- nos applicable_ _ ---- Plugging grout From . ,to----_—material vet rlVF1 sow • son 02/24/2012 16:32 5402899740 BURNER PAGE 02 reef • ._. __.. ..... ear . !►..tear 7` ALBEMARLE QI V, .. .. .._ WGMNtr *die . 9. State law requires submitting to the Virginia State Writer Control Board information about groundwater end welfs for every well made in the State intended lot water, or env other non•eaempt well. This infOrmetion must be submitted whether the well it completed, on standby, or ebendongd, Information reQUired includes an accurately and completely prepared water well completion report, full data from any aourfer pumping tests,drill cuttrnge taken at ten toot intervals funlaee exemption it secured', the results of any chemical tnaWaes and copins of any geophysical fogs,Ouerterly air pumping and use reports art required From owners tit public supply end industt,al walls County or Stoic permits 10 drill may be required in some parts of the note. Some counties require subrnieeion of a water well Comptat for+ report, The Virpinr.t Stair Hvaltlt Departmeni reouirm a water well completion err report for public wetly wellt llr ID,DRILLERS LOG fuse additional Sheets if necessary) 1t 12. DIAGRAM OF WELL CONSTRUCTION Her" i — ___ (with dimensions) DEPTH(feetf TYPE OF ROCK OR SOIL REMARKS Drilling elW F/ORI To (color,material,fossils,hardness, 11w315r,cav) fp etc.) .cavities, Time broken,more,shot,lets-l (Min.) Owe 0 15 Topsoil �� mpr 15 17 Clay; sandy topsoil 17 18 Gravels; sand & water 110, 18 45 Soft green slate; or granite 45 70 Hard granite (light green) 'I' 70 72 Soft place no drilling resistance .a. 72 90 Fairly hard light green granit 90 101 Softer lighter green granite mv101 115 Changed, to darker green color; drilling rate sa e X115 147 Changed to lighter green 147 162 Lighter green ..40.162 165 Soft place 1 GPM 165 175 Solid green granite 'x"175 197 Solid green granite; drilling rate same .,er197 230 Darker green granite ; drilling rate same 230 240 Real dark green granite, texture somewhat harder 1'1"240 272 Real dark green granite, softer texture, some wh to & t. n colored rock x,, 272 288 Texture same as above; more white rock mixed wit gray ock . Water 3# GPM 288 320 Rock has turned gray with less white *P320 390 Gray and green granite 390 397 White and gray rock mixed • x"`397 422 White and gray rock mixed - iew Nt Aibe NNW • reel 13- Well let dedicated) •Ste* ft X ft,Wall houtr7 vow Distance to nearest pollU,.lnt source ft.Type Distance to nearest property foe ft,Building '��"— o nq H, eats a 14, w*TER SERVICE RIP(; CPi5 Cei under ' ,,,,,,.State Water Control Board Regional Offices D.e.i for_. • minutes, Pitt,* sale rncne,, Malarial Vaney Reg.ON. piedmont Reg. Orr. owl 1G North Main Street 4010 Weal eroad Street Installer P.O.Roe 268 P. O. Boa 6616 Ooto 8ridgewater,Va. 22912 RlrMmpnd,Va 23230 X703.028.2596 804-257•1006 >eutnwost RCa.Off ♦iaewatnr Res Off 15, I certify ,het rho 'nform,rion contained herein is true and correct and that shit well aoa Cast Main Street 287 Pembrowe or tic.)Park and/or system has been initaiied and eonsnucred m accordance with the r 0.0,eoa 076 Suite 310 o0r*sbr0ke No, 2 IOr well construction a7 soecrfied in requirements eir'Abin9don,Va. 24210 Va.Beech,V .23462 city ordinances and the laws and rules of t pliance with ap alth of a county or inrl0pendanl 703.625•519] 806.595.9742 the Commonwealth of Virginia iWeet Central Rap.off. ,iyp.tner • vnainla nos. Olt. Signature ' Eaecullre Pork 5515 CMrvkee Aaenvt iSeofl,pate „e„7Df2 Peters Creek Road Suite 404 •IVvell driller or authontM Penonl Roanauc.W,/4019 Aieaandris, V . 27312 License No 703-982-7•32 703.750.9111 war• • INF *air ..Her lor 41414 s7-4A1C. -' . �, Disposal System Construction Permit PAGE OF Z" .� .sewage p Y• Commonwealth of Virginia Cli• Health Department Sr)--R - ���� Identification Number ���Department.of Health^ Map Reference1— 44 - l .J • ' 1),54--!"1 _ Health Department Now General Information .r New Q' Repair ❑ Expanded ❑ Conditional ❑ FHA ❑ VA ❑ Case No. "®' Based on the application for a sewage disposal system construction permit filed in .accordance with Section ,� 3.13.01,•a construction permit-is hereby issued to: Telephone �77 J��oiO Owner ����c , O! <h of U 1,A sM ` `-e rr zea • -- +� Address ,-/ /ot// C,cfip For a Type `� Sewage disposal system)which is to be constructed on/at I Section/Block Lot �,,,,. Subdivision �'� `t,' � ��5 Actual or estimated water use ya DESIGN, NOTE: INSPECTION RESULTS '" Water supply, existing: (describe) t Water supply location: yes Er no ❑ comments Mir Satisfactory _ To be installed:-class .---4-4-1 2U • rn�� ""' cased _ 2 ( ' �^ }' grouted ' mow Building sewer: Building sewer: yes pno ❑ comments l( '1 I.D. PVC 40, or equivalent. Satisfactory `" Slope 1.25" per 10' (minimum). ❑ Other I ' i! - Septic tank: Capacity -- � 9 als. minimum):) Pretreatment unit: yes Ip7no.❑ comments. lay ❑ Other ___ Satisfactory ""` Inlet-outlet structure: Inlet-outlet structure: yes isi no ❑ comments ,,_ PVC 40,4"tees or equivalent. Satisfactory ❑ Other —— Pump and.pump station: Pump&pump station: yes 0 no ❑ comments • r No O� . Yes ❑ describe and shown design. Satisfactory 6 II\ if yes: .. a v.. -t- es ono ❑ comments Gravity mains:3'q, or larger I.D., minimum 6" fall per Conveyance method: y D — 100', 1500 lb. crush strength or equivalent. Satisfactory �lc\tin f u� tom ^ rC ❑ Other 1 .r Distribution box: Distribution box: yes Q-o ❑ comments ""` Precast concrete with ___ _ports. Satisfactory ..ise ❑ Other _ ` Header lines: Header lines: yes p-----no ❑ comments ••••• Material: 4" I.D. 1500 lb. crush strength plastic or equiva- Satisfactory .., lent from distribution box to 2' into absorption trench. Slope 2" minimum. • •• Cl Other y.. Percolation tines: Percolation lines: yes D ono ❑ comments Gravity 4" plastic 1000 lb. per foot bearing load or Satisfactory equivalent, slope 2" 4" (min. max.) per 100'. — 0 Other - Absorption trenches: Absorption trenches: yes p"no ❑ comments 1 �r Square ft. required I CC%C depth from ground surface Satisfactory l .yeti i• -r.• to bottom of trench 7;7"` ; aggregate size L's"l'\: - '�' `Ls"`� Trench bottom slope 7.--`4 I 'DO / center to center spacing _ i; trench width Date ��"�l S3�i `tIn pected ar(d approved by: v , _ _ +.r F � sanitarian C.H.S.202A Revised 4/83 N NW/ NNW ®.r LI— NAV . • • • Health Department 5 D_�3 '- 4 b 1 *. Identification Number vsy"or YSchematic drawing of sewage disposal system and topographic features. PAGE Z OF L r Show the lot lines of the building lot and building site, sketch of properly showing any topographic features which may impact on the design of the system, all existing and/or proposed structures including sewage disposal systems and wells within 100 feet of sewage disposal system and reserve area. The schematic drawing of the sewage disposal system shall show sewer lines, pretreatment unit, pump station, conveyance sys- tem, and subsurface soil absorption system, reserve area, etc. When a nonpublic drinking water supply is to be located on the same lot show all Auw sources of pollution within 100 feet. r law ❑ The information required above has been drawn on the attached copy of the sketch submitted with the application. Attach additional sheets as necessary to illustrate the design: Nor 7jD .� . • VW • 411• • 'ar f • VIlly • 10 \ - i $4 my �0 .1 /1 I I b •. - . i �� 'Z eilill a(( • nary ` A r' I i l r • .,�, ` , III \co k j7.1)1\ ; ®s► The sewage disposal system is to be constructed as specified by the permit ❑ or attached plans and specifications ❑ . ,.u► This sewage disposal system construction permit is null and void if (a) conditions are changed from those shown on the application (b) condi- tions are changed from those shown on the construction permit. If construction has not commenced within 12 months of date of issuance, the ,or, construction permit must be revalidated. No part of any installation shall be covered or used until inspected, corrections made if necessary, and approved, by the local health department Nur or unless expressly authorized by the local health dept. Any part of any installation which has bean covered prior to approval shall be uncov- ered,if necessary,upon the direction of the Departure{ ••41W Date: q�I�/�3 Issued by: C-7-‘ V, i\\ILQ-- Aiw Sanitarian m.. Date: . C.33 Reviewed by: �r�A^'\ ( �' APIA_ J Supervisory Sanitarian Nosy If FHA or VA financing . — Reviewed by Date Date • Supervisory Sanitarian Regional Sanitarian *4W C.H.S.202B Ravlsad 4/83 • NIllY alts air _• ' COMMONWEALTH OF VIRGINIA Fo..n GW•2 • low 1375.1o,000 WATER WELL COMPLETION REPORT •BWCM No. __ I liar State Water Control Board • . (Certification of Completion/County•Permtt) - low P. O.Box 11143 ' SWCB.Permit '• 2111 North Hamilton St. County-Permit • _ Richmond,Va.23230' Certification of inspecting official: [/�j J /t This well does does not County/City ►7/�e „l w1 A e ° meet code/low requirements. County/City Stamp s• tow •VirginiaPlane Coordinates p Date • �. N •Owner C t`� , `\e s n y Y • : For 011ice Use _ E •Well Desig naatiior ,rr Number ,, [ asr Latitude& Longitude Addresslv2 T ;�h�i I� t N i ! �n L�5 U r 1�P j �JQ Tax Map I,D.No. i--_- +r • w Phone 7 - ' , . i - Subdivision_ _ Section • IOW •Togo. Map No. c#i°, mitt 3 i ._ Elevation _ 1 ��L�� COQ • It •Drilling Contractor tt., s{��,tx n C Block�`� s� •Formation Address p, , I}UX 818 ii)GG'IafioX, Va. 2452 Lot_____ • •Lithofogy hnna 1152,..1a12 Class Well: I •, IIA see✓ • -- 118 IIIA IIIB _ •River Basin Phone - - " __ IIIC _I(ID. IIIE_.:__ IOW •Province •Type Logs WELL LOCATION: (feet/miles direction) o1_ 1111W •Cuttings and. feet/miles T 2 . T k� Q a Vie? •Water Analysis (If possible please include map showing location markedf� re tD '' —Pt.. r c/ ',v; T air o 1 h 0 -p L n —�j Bra YC r-a •Aquifer Test ' Date started __ • Date completed Type rig -------- air I.WELL DATA: New V Reworked Deepened_._ _ 2.WATER DATA •Water temperature____,____ __�OF •Total depth T �_— -- ft. •Static water level (unpumped Level•measured) ___ _ _ It. err ft •Stab lized measured pumping water level It. •Depth to bedrock ��j(� _ --- •Hole size IA's()include reamed zones) •Stabilized yield gpm after_ __ Vie __hours • inches from /)^ to ,' C ft. Natural Flow: Yes.L/ryo _ ,flow rate. g pm +•r • i i ncnes troin rr V to r]?� _.tt Comment on quality___ _ . • ;inches f r o m _` to , f t 3.WATER ZONES: From� To____ vise *Casing size It D.1 and material From_ To , From J To • � � inncch���es,trorn (� _ to �_ ft From To From To ' — •rr Materiaal_ \V ______— 4. USE DATA: , ,� Wt.per toot or wan thickness in. Type of use Drinking ✓', Livestock Watering • inches from • to ft Irrigation_ Food processing__. ,Household V^-- Asa Material Manufacturing ,Fire safety .Cleaning_ 1 — Wt.per toot or wail thickness in Recreation ,Aesthetic .Cooling or heating Alio • . . . 'inches Iron to _ _ft. Inlection_i ,Other _� ��` `• — Material _ •Type of facility: Domestic bl,c water supply Wt, per foot or wall Thickness �._� m , Public institution Farm__. . Industry — -, `— •Screen size and mesh for each zone (where applicable) . Commercial ,Other _ • inches from to____ _ft 5.PUMP DATA: Type 5 v ir,_t Rated N,P,__ f .� _ '� •Mesh size TYPE —_ •intake depth/g��Capacity_ at ,�head_•• -inches from__� to ft. 6.WELLHEAD: T t _ YPt well seat air •Mesh size Type __ __ _ Pressure tank le) gal., Loc.__ s _ IS, • •inches from_ ^_to __. _It., Sample tap_ ,Measurement Port •Mesh size _Type _ �. Well vent ,Pressure reli_1 valve!_ _ 'r` • -inches from to ft. Gate valve ,Check valve Iwhen required)._ •Mesh size • Type _ Electrical disconnect switch`on power suppiY air 7.DISINFECTION: Well disinfected yes no •Gravel pack - - •From _ to It. Date_ _,Disinfectant used, - • •From to ft Amount , Hours used _ +eer 0 8.ABANDONMENT(where applicable) •y•a no . •Grout T - •From to (9 o ft ,Type fl(_fJ}( Casing pulled yes_ no __ not applicable ar �� •From to ft.,Type Plugging grout From ' tO .__material . a. 31•. OVER ar .r Vow Water Supply and/or Sewage Disposal:SysteM Construction Permit Page 1 of ,1 - — Corrimonwealth of Virginia Health Department Department of Health Identification Number:_101-00-0514 yaw ALBEMARLE CO.HEALTH DEPARTMENT - Tax Map Number: 57-79B-229(W) 'i' General Information BP#: i • Water Supply System: NEW • _ Sewage Disposal System:VACANT LOT Based on the application for a sewage disposal system construction permit filed in accordance with Section 2.13 E:of the Sewage Handling and - - -- - Disposal Regulations and/or Section 2.13 of the Private Well Regulations a constructiontpeernitlis hereby issued to: Owner. F.F.BAINBRIDGE Telephone: 804-979-8484 Arr Agent: WILLIAM J.GORDON Address:300 2ND STREET NE,CHARLOTEESVILLE,VA 22902 For a Type Sewage Disposal System or Well to be constructed on/at 250 W.TO 3 NOTCHD TRACE,GO 200 YDS.TAKE LEFT TO LAKE DAM See/Bk Lot Actual or estimated water use 600 epd- 4 bedrooms vow DESIGN NOTES; SEWAGE DISPOSAL SYSTEM IN CTION RESULTS 41rr Water supply,TO BE INSTALLED I Water supply cation:Satisfacto yes no — I GROUT CAP To be installed: CLASS:11IC I j ''r J CASED:20 feet GROUTED:20 feet I EHS / \ DATE 0fr vow • Alor WELL PERMIT ONLY low t3Qa� \N‘C -*\N OVeirN WNW ;,�\-e , VCS a-S63 • IOW IOW milor ANW A. - — -- --_ -- ------ --- - - - ___ 4 =.r Page Number 2 of 2 Health Department �t■r Identification Number 101-00-0519 • - - Schematic drawing of sewage disposal and/or water supply system and topographic features. Show the lot thee Otte Lading dm.sketch of property ahawng any topographic features with may road on the design of Sr.wel or sewage disposal system.irclud'np aisfing smite proposed Wurd,ra and sewage disposal systems and wells wthh 200 feet.The ethernet drawing of the wee site or area ardor sewage disposal system rr shall show sewer bus,prebabnera unit,pump station,conveyance system,and subsurface sots absorption system,reserve area,etc.When a d water supply Is to be permitted,show all sotrca at pollution wither.200 feet. � 0 _tee 0 The information required above has been drawn on the attached copy of the sketch submitted with the application. +ear ear vsr +ar PI �' ear � rer 25'Radius IIIC Well Area around Flagged 24"Hickory � Proposed House Proposed Drainfield Area 75' lor (Pending Health Dept.Approval) 896 Slop -104'+ 243' 80' ler NNW '(to Back Centerline of House) reel! +e Slope IOW war mar Install: pL IIIC Well rr Case and Grout 20' Min vor Not to Scale war This sewage disposal system and/or water supply is to be constructed as specified by this permit. Ater This sewage disposal system andfor well construction permit is null and void if(a)conditions are changed from those shown on the wow application(b)conditions are changed from those shown on the construction permit. No part of any installation shall be covered or used until inspoctod,corrections made If necessary,and approved,by the local health ray department or unless expressly authorized by the local health dept. Any part of any Installation which has been covered prior to _ approval shall be uncovered,if necessary,upon the direction of the Department. ire _ • Date: Q9/26/QQ- - Issued _ ` : ; i/ i / This Construction _ - - Permit Valid until_ •- - - 'way -- ZV ZD Qb—— En •• i � r r 1st Date: 9 Reviewetl by, rya - — 0312612005. - — r, Environmental Health S..: • • r leer • +see wan VW ably 0 —PAGE-- _ _ r- 4/25/2005 16:20 14349736830 FOSTER WELL & PUMP 62 —• VW err . • . • • el. - Commonwealth of'Virginia _ _ .. Uniform Water Well Completion Report Tax M � _(rVD � ✓ r► Owner r L. i_ ♦ I►'t'' -iD ...... , . • V1314 Pella__.. f v„ . Address 0 _ � � • 'raa t •` i. VWGe Psrtna . VWC13 la w Phone Count/ Location • : . .,11.1! - • • IOW ' Well Data' - .rr orm General Intstion Oat'Completed Totatl G,pw 4f weq__0.--_ , Drilling Method Yield --��GPM) Length a Ted ger Depth to t edrodc__- Natural Flew{Rate)_ ®r► Static Water Level Stabilized Water Level_____ NatuuM Used Well Disinfected (Y or N) _ audnSactant Used in. . •' �a . (rasing r To From �- (� From______ ------ Matenal ar S,o rr 1-(2..., t° Sizo��Material Slze, ____ Aar Size J�.25 -Material Weighr/Schadule WaighUSChodule—________ ..rocnt/Schaduie • V :;rev,.+ Pace From -.._. To .n,-• ... •- --- To From�._To..,�._.. . er► au• - / From To From __To----. .-ram . L�✓ 'Bore Hoia SIZO 7c !! "' •Bore Hole Size c. Bore Kole Size Type kiedint, Typo ••- Type Method, ._-- �" !Actr�ac - erg Method yr water Zone or Screened,. c / .. MOW (.. From 1 SS' To �7 b From• To From Meal!Size ww Mesh Size T Diam Z.Mesh Size------To- From. ___;. To m From To Mom Diem Meslt SIZe. ' Oiam — . '� t.iosn Size �Diam Mesh Size, ' UsQ Data ' mow r, Pr'vale Weis: Domestic Agrxultural Industrial Monitoring • 'ublic Welt: Community -- Non Community VW VW • Anartdonment Information• or Oared or Dug Wells Walls°that than Bored Wells Casing Removed,Y or NZ: Casing tornoredr Y or K? • +r Depth so which casing Masi d*lt.„ II Y, Depth to a of Wing was removed: p •d gravel/sand l/sand it . Dept!) and Typo of Pitt: Applicable,depth{s),and type g •Source of gravel or sand - Scurte of Fill .4. 9ontenito Plugs: From to From to to From to� Cement:Rpm��. rr - e Melnod of permanently marking loci-bon:- - - _- - -.-•`-- - - - _ err _ _ __- --- -- -- __ -_ _-- y_—_,;„—�_—_ -- ---- ---- - - - — •viii -e . •r► • 1 . _ • AIM +r .r law 04/25/2005 16:20 14349738638 FOSTER WELL & PUMP PAGE 03 • l Cr�rv� 1�0 a Teacs, • 101` • Drillers Lop• Depth Gescrialiog a Formation or Sediment aerrtarkt P-0 c/ffec pro,, 6/ 7n.4, sf �d1J5 k• 2,D (7. , , ( .it ,0 .z0.0 01 eas, / ..w 2_0 616.. scryr-fati. c70 (.( .5/-•6717 5c44*--,1"Avc 2(0 2-5v 1 + , r)ek. cv ,2 S rXr� ic .305 .fd.W- 0 ?v (P.,2 ley '"" Neer additional Sheets lr necessary).. . 4r ier candy that the irttoaaatian contained hats L We and itul•ihis will west installed and cansittiOad in accordance with the perms Inc tuMer that the Well compiles with ail appicihiN statei4kOlopyliltioAs itordinsnc s and Lama. .t Name PO TER WELL 4..PWeiC0-Dm r • ,' ti: :4 �.a221 .►1' 8117 • •Y,...w ) , • iter Phone tFT:L�yi�s..: r f ezLr 4.. g Dri�ors Signature. w late Flspraaee►tit�p YOSTP3• & j ;NC *NW vuptnts Contractors UG10144 Number )701 1 G1 vi tier _ r bop / Disposal System Construction Permit PAGE L oFz iliw Sewage p Y ' 41110 • Commonwealth of Virginia �' Health Department iew Department.of Health a Identification Number '- (*1 " kl (Ob "(T •s)i 5$Y∎C Health Department Map Reference c7-(-,13- /I/ General Information l"` New (ia" Repair ❑ Expanded ❑ Conditional ❑ FHA ❑ VA ❑ Case No. . vier Based on the application for a sewage disposal system construction permit filed in accordance with Section 3.13.01, a construction permit is,hereby issued to.:� *or Owner l r" n tJ-� • L >,• -ti's,, 1 J r 1_ Telephone 73- 4/ '7"1 Address r• X I (- ? , •1-, ? ? , v A For a Type ' , Sewage dispo al system which is to be constructed on/at ____- __G, S ' Subdivision Section/Block __ Lot "w Actual or estimated water use ' lir DESIGN NOTE: INSPECTION RESULTS .r Water supply, existing: (describe) Water supply location: yes '( no ❑ comments err Satisfactory To be installed: class for cased 7o/ grouted __fin - _ • Building sewer: Building sewer: yes no ❑ comments Apr 4 ' I.D. PVC 40, or equivalent. Satisfactory law Slope 1.25" per 10'(minimum). . • ❑ Other Iry f Septic tank:,•Capacity 1 C` gals. (minimum). Pretreatment unit: yes Er no ❑ comments `r` ❑ Other Satisfactory vrr Inlet-outlet structure: Inlet-outlet structure: yes 'no ❑ comments PVC 40,4"tees or equivalent. Satisfactory yr ❑ Other vow Pump and pump station: Pump&pump station: yes to no ❑ comments No O---..- Yes ❑ describe and shown design. Satisfactory P401' vow if yes: i / "" Gravity mains:> "or larger I.D., minimum 6" fall per Conveyance method: yes ["no ❑ comments „r, 100', 1500 lb. crush strength or equivalent. Satisfactory ❑ Other r r®r Distribution box: Distribution box: yes no ❑ comments '4W Precast concrete with- ) ports. Satisfactory ❑ Other i.. Header lines: Header lines: yes .12//no ❑ comments 'v Material: 4" I.Q. 1500 lb. crush strength plastic or equiva- Satisfactory tir• lent from distribution box to 2' into absorption trench. Slope 2" minimum. mine i1 Other Percolation lines: Percolation lines: Yeas—e no ❑ comments Gravity 4" plastic 1000 lb. per foot bearing load or Satisfactory law equivalent, slope 2" 4" (min. max.) per 100'. ❑ Other 'NNW Absorption trenches: Absorption trenches: yes ,3no ❑ comments *4W Square ft. required i?00 : depth from ground surface Satisfactory �, to bottom of trench �,( '' ; aggregate size^•C.-1. : Trench bottom slope L 4 ' I { DO i� 'a g — center to center spacing 9' ; trench width 3 Date Inspected and approved by: "' U .t r) .'mot _ �' , 6- -... . . f. .� ' Sanitarian rlrr C.H.S.202A Revised 4/83 saw ir► VIP' Vale..) Health Department Identification Number �y w `' k�t t. 7.-7.- Z �. 'w Sctsamatic drawing of sewage disposal system and topographic features. PAGE OF I., Show the lot lines of the building lot and building s ite sketch of property showing any topographic features which may impact on the design of the system, all existing and/or proposed structures including sewage disposal systems and wells within 100 feet of sewage disposal system and 11r reserve area. The schematic drawing of the sewage/disposal system shall show sewer lines, pretreatment unit, pump station, conveyance sys- tem, and subsurface soil absorption system eserve area, etc. When a nonpublic drinking water supply is to be located on the same lot show all ,tiw sources of pollution within 100 feet. bri .. ❑ The information re uired above has been drawn on the attached copy of the sketch submitted with the application. ;y- Attach additional sheets as necessary to lilustrate•the design. �r / to -------(f) - ,o k ,_____ iier �% •\ e�• r V( I pp COO) ,r. .-- _ - cp 110* ç 1 VIP l .4(j) V• ANY 0 let} }-cu • 1111+ �/ rqr O u` / t MC 'VW r t` f f, - ...1- krr• �.. � r ) I I; .1111► ,� 1111 ar. I 1 +1111 /1111► t�o Nor The sewage disposal system is to be constructed as specified by the permit Q or attached plans and specifications ❑ . V„ This sewage disposal system construction permit is null and void if (a) conditions are changed from those shown on the application (b) condi- tions are changed from those shown on the construction permit. Mgr No part of any installation shall be covered or used until inspected, corrections made if necessary, and approved, by the local health department or unless expressly authorized by the local health dept. Any part of any installation which has been covered prior.lo'approval shall be uncov- ered,if necessary,upon the direction of the Department. iiror Date: 1" et- Issued by: ,, i ^� This Construction oow v Sa oar, Permit Valid until yr Date: 11- 1 CI 0 el Reviewed by: ,\\-wM \ i C A AA/P-- / �'-'I-1S r � 1Supervisory Sanitarian low �, If FHA or VA financing - ;a_ r d 5— Reviewed by Date Date --- _ Supervisory Sanitarian _ w' Regional Sanitarian lo G.H.S.2028 Rer�seO 6ra.4 11-2A war 111111111.111111=111. 11.111111.111.11..M11101111111.11=11.1111111111111111.1.1.111 ANY •rr ■ •r tee F�/,n GW-2 COMMONWEALTH OF VIRGINIA 4978-16,000 Air WATER WELL COMPLETION REPORT ••BWCM No. law State Water Control Board (Certification of Completion/County Permit) P.O. Box 11143 2111 North Hamilton-St. SWCB Permit_ _ Richmond,Va.23230 ) County Permit . • k'' � A 1���� % Certification of inspecting official: Countyf d! C//Q(J This well does does not sire meet code/low requirements. CountylaiorSta p S low •virginiaPtene Coordinates / ( /��T �n — Date N *Owner �o h N ti- ( `vim !C �r For Office Use E •Welt DesignsttR nor Number +sir Latitude& Longitude Address / c)lc �6. 7 N -� JC i 1 7 1r 4. a-2 9(L•S Tax Map I.D.No. -- mp yy Phone ` Subdivision •Topo.Map No. �+ Section_ — •Elevation ft. •Drilling Contractor (yrii]�1 t_ MLidd7 D�.ri/In/ep /,d Block___ •Formation Address 7-0% 2coc 1300 1 Lot ANY •Lithology I40C1I4.%)^n./ i14. 1•(/.!) 1 Class well I IIA trier •River Basin Phone '70 3 - 2S51 -,.4-4 7 IIB nlA_ •, 1118 ,_._ •Province IIIC _IIID l)IE___ — •Type Logs_ i WELL LOCATION: (feet/miles direction) of •Cuttings and feet/miles (direction) of •Water Analysis I I f possible please include map showing location marked) ,r •Aquifer Test ^ j' _ Date started /2' 2c- g�f • Date completed-I2 -.2.O '9 ei Type rig ki/Z P..6 /,,,,/L j� •rn // I.WELL DATA: New j,./:Reworked Deepened 2.WATER DATA •Water temperature of kew •Total depth 4-0 ft -- --�~ �� / •Static water level(unpumped level measured) _ _�.2. _ It. •Depth to bedrock '7 4 ft. •Stabilized measured pumping water level __ ,2 It. vow •Hole size(Also include reamed zones) •Stabilized yield 7.5— gpm after_ .2. _hours vow • IO inches from 0 _ to 78 ft. Natural Flow: Yes No ,flow rate gpm • /(p _inches from 78 to is-(7 It. Comment on quality __ '•Is' • inches trom ^ to ft. 3.WATER ZONES: From//t)__To_.L.20---- *Casing size(I.D.)and material From To . From _ To_ •re • inches front Q f.Z- to 7�y�_ft. From_ To _ From To - Material S4 tfc� - T_-�- _ 4. USE DATA; Wt.per loot Or wan thickness in. Type of use: Drinking L-"*".. , Livestock Watering , _ _ kir • inches from _to ft Irrigation Food processing___ .Household Material Manufacturing ,F ire safety __ .Cleaning_ Wt.per toot or wan thickness in. Recreation ,Aesthetic__ ,Cooling or heating °• inches from to ft. Injection •Other vow Material - • �_ •Type of facility: Domestic f--.<Public water supply ANY Wt.per toot or wall rhicknrss ______/n. Public institution_ Farm____ ,Industry- __ •Screen size and mesh for each zone lwhere applicable) Commercial_ ,Other — __• inches from_ to ft. 5.PUMP DATA: Type _ I Rated N.P. ^ ~tiff •Mesh size Type •Intake depth ♦Capacity--- -at head • inches from )o- __ it. 6.WELLHEAD: Type wen seal xter •Mesh size Type _ _ _ Pressure tank gal., Loc. __ ' _ _ • inches from to____ - ft Sample tap .Measurement port "ilw •Mesh size Type _ Well vent ,Pressure relit valve - _ _ •er • inches from to - - ft. Gate valve ,Check valve)when required) •Mesh size Type Electrical disconnect switch on power supply New •Gravel pack 7.DISINFECTION: Well disinfected ✓ yes/�� no •From to ft. Date/2-2-04'Y ,Disinfectant used_IP,/.r/ ,•110, •From to _ ft. Amount , HOurs used - •Grout -- 8.ABANDONMENT(where appticablet •yes no •ir •From e to ,-O it..Type �,. 1?FAI Casing pulled _ not applicable 9 P u Yes no ,�„ •From to ft., Type ^" --� _ Plugging grout From _to_ _material OVER VW wrr law NOY VW Mir • IOW Owner ._ )._1/t _..Lr A .7:7 -'14)7L-r172 BWCM No. --- NW `rely' 9. State law requires submitting to the Virginia State Water Control Boars information about groundwater and wells for every well made in the State intended for water, or any other non•exerty,H well. This information must be submitted whether the well is completed, on standby,or abandoned. wear Information required includes: an accurately and completely Prepared water well completion report, full data from any aquifer pumping tests,drill cuttings taken at ten foot intervals (unless exemption is secured), the results of any chemical analyses,and copies of any geophysical logs. Quarterly pumpage and use reports are required from owners of public supply and industrial wells.County or State permits to drill may be required in some parts of VW the state.Some counties require submission of a water well completion report. The Virginia State Health Department requires a water well completion report Icr public supply wells O.DRILLERS LOG fuse additional Sheets if necessary/11. 12.DIAGRAM OF WELL CONSTRUCTION ttatr (with dimensions) taw DEPTH(feet) TYPE OF ROCK OR SOIL REMARKS Drilling From To . (color,material,fossils,hardness, (water,caving,cavities, Time etc.) broken,Dore,shot,(etc.) (Min.) r. 8E------ O l 94)7. new NW �o r In 74 L14-61 feRo Kc:1t1 • x.i /Yo 'ill-645 /e P°CI D L t Cl ,c-• t �ti 1 r a gee OOP XIIW 41W .. 0b618- /p>>� li" fin) 4'0 ;? �vP v suer 13. Well lot dedicated? ;Sae ft.X ft..Well house? _•� A Oistance to nearest pollutant source ft.,Type Distance to nearest property line _ ft..Building ft. Nov (4. WATER SERVICE PIPE: Ch•ce•d under _ P•s.i, for— 'OW State Water Control Board Regional Offices minutes. Pip• sire incn•s, Met•ricl ■ Valley R•g.Off. Piedmont Reg.Oft. Installer —. �_ Isar 116 North Main Street 4010 West Broad Street P.O.Box 268 P.O.Box 6616 Dote Bridgewater,Va.22812 Rirhmond,Va 23230 703•825-2S9S 804.257.1006 • Southwest Reg,Off. Tidewater Reg.Off. 15. I certify that the information contained herein is true and correct and that this well 408 East Main Street 287 Pembroke Office Park and/or system has been installed and Constructed in accordance with the requirements P.O.Sox 476 Suite 310 Pembroke No.2 for well construction as specified in compliance with appropriate county or independent w, Abingdon,Va.24210 Va.Beach.Va.23462 city ordinances and the laws and rules of the Commonwealth of Virginia. 703.628.5183 804.499.8742 _164_1(.4)2.. ZSr�Q maser Wst Central Reg.Off. Northern Virginia Reg.Off. Signature `S. (Seal).Date 2 eY J Executive Parx 5515 Cherokee Avenue (Well driller or authonted person) 5312 Peters Creek Road Sult••04 License No. IOW Roanoke,Va.24019 Aiexandna,Va.22312 7011-982-7432 703-750-9111 "` AJ�r:6bJ COO✓TY c'1/ D T /��� /e'61 �1,1c�co to ff r ... P.O.P. , Rog 7616 / �- �2�`$S Gh4d/6 ttES I ll6, 1/A -137O& N Amor low INW ler - --- ---._. � ' S - c7 - 73 - • ' "'' _ 1 Sewage Disposal System Construction 'Permit PAGE . 1' OF Z' .r, Commonwealth of Virginia Health Department b- 7- 3Z Dep_e[t ntof Health( 'Identification Number �,., ( �-•,�-s Health Department Map Reference ,/ "73< , ,) %.--"" Sri. General Information • . New Repair ❑ Expanded ❑ Conditional ❑ FHA ❑ VA ❑ Case No. 4111.• Based on the application for a sewage disposal system construction permit filed in accordance with Section 3.13.01, a construction permit is hereby issued to: r • / g Owner l.1-. +, _ _ Telephone O "' ��8 ,_ Address ��ti,�E.1 l' atr4. r 1 a,t �o-, �, ..a..,�a.. • ' • . For a Type _..1-- Sewage disposal s stem which is to be constructed.on/at V 5� • ' -��" i '• 1 , 0 e,1r . i .1• 2:1/4- • v Subdivision �rIM& 1 Section/Block Lot ' g+' Actual or estimated water use ••0 1 , ley • DESIGN �t NOTE: INSPECTION RESULTS \ Water supply, existing: (describe) ______ 1 Water supply location: Satisfactory• yes ❑ no ❑ — comments To be•ins_falled•class "j:. --- G.W.2 Received: yes ❑ no ❑ not applicable ❑ .r ca ' grouted '1 ,' INF Building sewer: Building sewer:, yes comments low kltet t I.D. PVC 40, or equivalent. Satisfactory %- . . Slope 1.25" per 10'(minimum). . - .,,,r. ❑ Other ________ — • , Septic tank: Capacity _‘ ?Go gals. (minimum). Pretreatment unf:f• --•+ yes no ❑ comments "r ❑ Other ' Satisfactory ' . . •.r Inlet-outlet structure: ;•-Inlet-outlet structure: yes Ip no ❑ comments PVC 40,4"tees or equivalent. 0 Satisfactory ' or ❑ Other -- '.._,+t . li, Pumped pump station: Pump&pump station: yes DI ono ❑ • comments Nod Yes ❑ describe and show design. Satisfactory l . ' if yes: f Q 1 �, Gravity mains: �3'�or larger I.D., minimum 6" fall per Conveyance method: yes �no ❑ comments 100', 1500 15. crush strength or equivalent. Satisfactory . l r ❑ Other Distribution box: Distribution box: • yes no ❑ comments `"' Precast concrete with I b ports. Satisfactory .r,. ❑ Other • Header lines: Header lines: • yes comments • •rr Material:4" I.D. 1500 lb. crush strength plastic or equiva Satisfactory - - lent from distribution box to 2' into absorption trench, . Slope 2"minimum. v,r fl Other — ` 0"---no . • Percolation lines: . Percolation lines: yes ❑t comments ter, Gravity 4" plastic 1000 lb. per foot bearing load or Satisfactory • rr equivalent, slope 2" 4" (min. max.) per 100'. ❑ Other I . Absorption trenches: ,�fI • • . ' Absorption trenches: yes �o ❑ comments . • ,�, Squaie ft. required 1-+6: depth from ground surface Satisfactory to bottom of trench aggregate size 0,S.'1;<': . Trench bottom slope 2- " r ! trrj ' ; tt �j center to center spacing , 1 !,-trench width _ Date _tv- '-br Ins•-•ted_and/approved�by: yr Depth of aggregate. 13 / `F.0 �. -- 1 Trench length qi1 ; Number of trenches L. Sanitarlan 1 *o+ - - --• --- _-1. _- • .- - •- - .- - -- C.M S.202A Revised 684 11-2 • LENMININMiNmmuiriscaMmastammuswommarc-mar... . . Mir 4i, NOW vow . -• • Health Department —R7 — 3 Z9 ii'.'' Identification Number !� aw to e. 1.....--'-issr Schematic drawing of sewage disposal system and topographic features. PAGE L OF Show the tot lines of the building lot and building site, sketch of property showing any topographic features which may impact on the design of low the system, all existing and/or proposed structures including se,vage disposal systems and wells within 100 feet of sewage disposal system and reserve area. The schematic drawing of the sewage disposal system shall show sewer lines, pretreatment unit, pump station, conveyance sys- "r tern, and subsurface soil absorption system, reserve area, etc. When a nonpublic drinking water supply is to be located on the same lot show all . sources of pollution within 100 feet. ti/ ililly low ❑ The information required above has been drawn on the attached copy of the sketch submitted with the application. Attach additional sheets as necessary to illustrate the design. Aar l.r low t e.r �� t� d All/ \. t t,E 40� r ,N 1111, �` q"41 {S 1 . 4 V -v - 41 .,,1� 0 10- — - ..\ t t� D1'� / / IOW tc‘ • L\J d Ztct f ley The sewage disposal system is to be constructed as specified-by or tied-by the permit attached plans and specifications ❑. `e✓ This sewage disposal system construction permit is null and void if (a) conditions are changed from those shown on the application (b) condi- tions are changed from those shown on the construction permit. / VW No part of any installation shall be covered or used until inspected, corrections made it necessary, and approved, by the local health department wr or unless expressly authorized by the local health dept. Any part of any installation which has been covered prior to approval shall be uncov- ered,if necessary,upon the direction of the Department./ Date: _ { ^2.2-87 Issued by. MN - f\i'-' .r Y �� This Construction Sanitarian Permit Valid until "" Date: _ Reviewed by: I •ZZ TD SupervisorylSanitarjan r - _ . . r,..31,\, •v , v ,—t.'--\ .411r If FHA or VA financing - -- -- - -- - -i\-...; .... - - "r Reviewed by Date — Date • 441, Supervisory Sanitarian Regional Sanitarian C.H.S.2025 Revised 634 1 1-0A vow s A. low 'lr IOW te . _ . `P r;cw°2- COMMONWEALTH OF VIRGINIA - • • .r. t»e•fo,00a WATER WELL COMPLETION REPORT •BWCM No. ___ __— . • rr • ••vow Stita Water Control Board (Certlfication of Com(J/BllOf/Count}/ Pefl77/I)' ' P.O.Boa 11143 ' ' - - SWCB Perrnit • . - - - 2111 North.Hamitton St. •' Richmond,Va.23230 County Permit ' srar �/ /�` Certification of inspecting official: i A This well does does not • lire, • County/City - meet code/low ieQuirements. ' ' • County/City Stamp s •Virginia Plane Coordinates 1 Date _ N ••Owner jell,')(, T •• • For Office Use• ®r •. . . - E !Well Designation or Number . __ _- • ••Latitude& Longitude Address • �► N --- Tax Map 1.0..No. . .. - Amor _ w Phone - . • . . Subdivision_ _ . • - .• • Section Topo.Map No. _ 'r► .0 Elevation' ft •Drilling Contractor V fHP Gth.if C . Block__ - • • • • address_ - Lot •Formation ---- - VIII" Class Well I IIA _ . •Lithology ' --- •River Basin_ - Phone . • '17>-" %L) !, 1(6 MIA - MB ._- var •Province _ ' t11C _IUD 1I1E: tai/ : •Type Logs WELL LOCATION: - (feet/miles direction! of • • __-_ -.__._!____,__ -________. •Cuttings and,_ feet/miles • (direction! of • •r (If possible please include map showing location marked) •Water Analysis aw •AQuifer Test //r p /J Date started ��r a • Date completed ///j Type rrgy/7 Iry I.WELL DATA. Nerw7 Reworked •_Deepened _ 2.WATER DATA •Water temperature_._____ __,_—__-_,`.OF • ASV •Total depth Zp c ' - - - - It •Static water level funpumped level-measured) _.___ ft. •Depth to bedrock 3,4' ft . *Stabilized measured pumping water.level ____ It: taw •Hole size( Iso include reamed zones) •Stabilized yield _^ gpm alter-___ L/-- taw : taw • inches from 0 to It Natural Flow: yes- No flow rate • ' 7 g pm • C. inches trom 3y to ' tt. Comment on quality__-`-_--_ vow • inches tram _ to - ft. 3.WATER ZONES:-From;_To--_ • •Casing size 0.1 and material From To __ . From -_ To _ 'law • in�o�tes f[�om 0 to . 3 / 1t. From_ To__ From `To� - vier Material_//4 1`1'. __ 4.USE DATA: ,/ ' Wt.per fodt Cr well thickness in Type of user Drinking '✓ , Livestock Watering . vein • inches from to ft Irrigaticn Food processing.__— .Household• _, Material Manufacturing ,Fire safety __ ,Cleaning_ • 'taw Wt.per toot _ or wall thickness -_ in. Recreat;on ,Aesthetic__ .Cooling Or-heating `1111W • inches from _ to ft. injection Other __ •--- -- _ Material •Type of facility., Domestic Public water supply 'a✓ Wt.per foot ' or wall thickness ___- in. Public institution Farm-____ ,Industry-•- ,_, •Screen size and mesh for each zone(where applicable) Commercial ,Other VW' • inches from to ft. --� 5.PUMP DATA Type ___ •R,ited H.P. __ New •Mesh size— _Type •Intake depth ♦Capacity- __.__at _ head • inches Irons ___I 0 _ ._I1 6.WELLHEAD: T - ype well seat warn •Mesh size Type _ - -_-i_ Pressure tank Q • inches from__ It Sample tap ,Measurement port •v/' •Mesh size Type • ..._ - Well vent ._ Pressure reli.rf valve__ _ • • inches tram to_i ft. Gate valve _,Check valve twhen required) • Ally . •Mesh size Type _ Electrical disconnect switch on power supply ���^^^^ •'�r •Gravel pack 7.DISINFECTION: Well disinfected _ - yes . no r/-7 to ft. Date ,Disinfectant used _ titre, •From __ to __ It • r Amount _, Hours used . \_ vow •Grout - _ - - - B.ABANDONMENT(where applicable) oval _no__ \ •From CI to Lt) fI.,Type __, � Casing pulled yes __ no -_� nOt appliratile - - -�'r' it re, ---'•From- -to- t.__ _'t.,_T.ype- • • Plugging grout From__ _tO __material - ------ _____. air van OVER , n • -4Y ... 'as. .rte. 'Owner dillne./1"S — ----'',••••.....;;-;! ; .. 'Ai.'NO' °: BWCM No. —��a . 9. State taw tequilas submitting to the Virginia State Water Control Board information about groundwater and walls for every well made in the State intended for water, or any other non-exempt.well. This iliforrn tion must be submitted whether the well is completed, on standby,or abandoned_, . _.Inforrnation.required includes' an accurately and completely prepared water well completion report, full data from any aquifer pumping tests,drill 2. , • -•cuttings taken at ten foot intervals(unless,exemption is secured), the results of any chemical analyses, and copies of any geophysical logs.quarterly IOW "• purrpage and use report)are required from owners of public supply and industrial wells.County or State permits to drill may be required in some parts of ' • •t., the state.Some counties*require submission of a water well completion report. The•Virginis State Health Department requires a water well completion •• ' 'report for public supply wells. sea 2 10.DRILLERS LOG,(use eddrtional Sheets if necessary) - 11. 12.DIAGRAM OF WELL ' CONSTRUCTION . ets. (with dimensions), DEPTH{feet) TYPE OF ROCK OR SOIL . REMARKS Drilling - • From To .• (color,material,fossils,hardness, (water,caving, ' �, rq,cavities, Time •�- •te.) broken,core,shot,fete.] (Min.)•' Derr 0- '31 riw.l 5 ,44', p H s r • 71 "- r 6r,i}wo1'C' " •• , . . . . .. . .. MOW et.r . . . . . . . . . .. . . . . . . . . . . .. .. .. . . . ... ,_ . . . . . . . • acct • )1W .l. I ' • sail. 1 . +err r I 1 .. VP. . . kit.I P� LG°f • Neer 13. Well lot dedicated) .Size 'h.X ft.;Well house?- •• __ Distance to nearest pollutant source ft..Type. . . , Star' Distance to nearest property line • ft.,Building — ft. , 14, WATER SERVICE .PIPE: Checked under p.s.i. rot __. State Water Control Board Regional Offices minutes. Pipe 2;7e themes. Mot•ridl_ Valley Reg.Off. Piedri,ont Re Orr. Reg. Insto Het _ 116 North Main Street 4010 West Broad Street . .— ' . — —-.- WY • P.O.Box 268 P.O.Box 6616 Dote , Bridgewater,Va.22112 Richmond,Va.23230 . 703428.2595 804-257-1006 ' ail/' Southwest Reg.Off, Tidewater Reg.Oft. t5. I certify that the rntormatron contained herein is true and correct and that this well 408 East Main Street 257 Pembroke Office Park .and/or systern has been installed and constructed in accordance with the requirements' ` P.O.Bow 476 .Suite 310 Pembroke No.2 . :10f well const action as specified in compliance with appropriate county or independent Abingdon.Va.24210 Va.Beach,Va.23462 city ordina and the ws and rules of the Commonwealth of Virginia. sew 703428,3183 104.199.8742 //�� 4 /p West Central Reg.Off. Northern Virginia R•g.Off. . Signature (i ISeall,Date_" `C / 7 ..., Executive Park ' •5515 Cnvokee Avenue ' ' Well driller or authorized person) 5312 Peters Creek Road Suite 404 License No.' ' • •Roanoke,Va.24019 Alexandria,Va.22312 —_, ---• sew 701-982-7432 703-750-9111 - . . . - VW e.. err AMY MAW Water Supply and/or Sewage Disposal System Construction Permit Page I of _q Now Commonwealth of Virginia Health Department Department of Health Identification Number: 101-00-0647 vow ALBEMARLE CO.HEALTH DEPARTMENT Tax Map Number: 58-302-549 'eo General Information BP#:2000-2083 SF Aar Water Supply System: NEW Sewage Disposal System: NEW Based on the application for a sewage disposal system construction permit filed in accordance with Section 2.13 E,of the Sewage Handling and 'ow Disposal Regulations and/or Section 2.13 of the Private Well Regulations a construction permit is hereby issued to: Owner: SKYLINE HOME BUILDERS Telephone: 804-962-2071 Address: 1227 MOUNTAIN ROAD,CHARLOTTESVILLE,VA 22901 For a Type 1 Sewage Disposal System or Well to be constructed on/at St.bdivision: MERIWETHER LANE Amor SedBk Lot 3 Actual or estimated water use 450 gpd- 3 bedrooms low DESIGN NOTES: SEWAGE DISPOSAL SYSTEM INSPECTION RESULTS Aar Water supply,TO BE INSTALLED t I Water supply 1 cation:Satisfactory yes no '°'�" �i� g«i (dd j I GROUT / CAP / To be installed: CLASS:II1C J t ('ee � `1'" CASED:20 feet GROUTED:20 feet On(I War I EHS DATE -kit,•••W 1 . r e +rr Building Sewer IP 1.1).PVC Schedule 40, I Building Sewer: Satisfactory yes_/no � or equivalent.Slope I 1:.)"per lUit(inin.) I V /tt 7,/L—,. >or Other I EHS I- _ 1010 DATE 4_ 1(6_01 tr Septic Tank:Capacity:500 Gals.(min.) I Pretreatment unit: Satisfactory yes_no_ Al/ I Other I EHS l� DATE '� � 440W 4 -lb-0 l Inlet-outlet structure:PVC Schedule 40, I Inlet-outlet structure:Satisfactory yeso_ maw 4"tees or equivalent. I (.4 . *ay Other I EIIS DATE y —I e)—r,1 1 '� .r► Pump and pump s:atio:, I Pump&pump station: S tisfactory vcs NO EHS tDA 4 NOW Gravity mains: 3"or 1...eer I.D.,rain.6" I Conveyance method: Satisfactory yes%no_ Nur fall per 100 ft..1500 lb crush strc;..tth I kttt 6,4-.1° or equivalent. Other I EHS 4,16.--- DATE t Distribution Box: Prec-st concrete I Distribution box: Satisfactory ye_no_ V' with 6 ports. I Other I EHS L__ DATE yr Jam} n 4 i 'D` Header lines: Material 4"I.D. 1550 lb. I Header lines. Satisfactory yes%no_ Aar crush strength plastic c, equivalent from I ) /) distribution box to 2 ft In ,�f•.•�/ to absorption I 0110• trench.Slope 2"min. G:hcr I EHS \I.._ DATE G 1 �I -tb-off vow Percolation lines: Gruv.y 4"ptac::c I Percolatio lines: Satisfactory yesf no law 1000 lb.per foot bearinZ load or equiv. slope r-4"(min.max.)per 1008 1 tit /( �„ Other I EHS DATE y_y $ U 1 — 1:444. +rr Absorption trenches: I Absorption trenches: Satisfactory yes..//no� t,,.v€4 Sq ft.required: 1425 depth from +r' ground surface to boric,::of trenc;: 42": � \11 .-"'aggregate size .5.1.5": I EHS DATE 'r Trench bottom slope 2 :"/I00 ft 4 -1 - center to center spacin; t 0 F1': I Date_ 1 Q VI Approved by: {&,hi/114y I-° low Trench width 36"De;"':of aggro:ate 13": Trench length 95 ft: I 0-6- IOW Number of trenches 5 : I Environmental Health Specialists Aar CHS202A t — ,} . IOW we, ley e ww wr . Page Number 2 of 3 Health Department 01-00-Q647 wr Identification Number '""° Schematic drawinc of sewage disposal and/or water supply system and topographic features. Show Its lot lines of the bus a site,sketci of property showing arty topographic features which may Impact on the design of the well or sewage disposal system.includitg lDr' existing and/or proposed s::, i es and sewage disposal systems and wens within 200 feet.The schematic drawing of the well site or area and/or sewage disposal system shell show sewer Ines.IN a:. meat unit,G.:rnp station,conveyance system,art subsurface soil absorption system,reserve area,etc,When a nonpubSc drinking water supply hats be permeed,sr,-.,all sources of pollution within t. hin 200 fee ❑ The informatics. quired above has been drawn on the attached copy of the sketch submitted with the application. e, THIS PERMIT ISSUED UNDER THE 2000 REGULATIONS . war wr Ar Seer sloo I VW 50'x50'IIIC Well Area,Parallel to Cul de Sac war / Driveway,begins 20'From Culvert, I Install: 3 75 , a 5 Trenches Slope 20' 42" Deep Ali" 1 & I 95' Long \\ I 3' Wide �r \ Proposed House ' I 1 ' *r '. 143' 10 Centers luip � PL\ M y On Contour!!! w� 0)...ilt I wr i I,.. 1 It { . ,\z107' o43r 1 127' i G -� Q : Z to 1 fJ / , as 41 �' i + i war X510%' I�. Q iii I l 1121' wr 1 18 ' Ayr 1 Not toa' ,1 le VW wr This sewage dls, I syster and/or water supply Is to be constructed as specified by this permit. This sewage dispose;. ,om andlor well construction permit Is null and void If(a)conditions are changed front those shown on the iiw application(b)condic... ,are chanced from those shown on the construction permit wr No part of any instailat,. ,shall be covered or used until inspected,corrections made if necessary,and approved,by the local health department or unless o. .rosily atr.',orized by the local health dept. Any part of any Installation which has • , covered prior to ,ew approval shall be uncc, Aid,If necessary,upon the direction of the Department. ge i ' .y; This Constriction Date: 1 i 1/2000 Issued by: Permit Valid until Ili" — — En • mental Health Specialist 4111/ Date: - Reviewed by: _ 06/1112002 Environmental Health Supervisor wr VW Aar Nur lime VII FOSTER WELL _ PUMP CO . TEL . Jul 09,01 14 :31 No .006 P.02 • 1 Commonwealth of Virginia "` Uniform Water Well Completion Report ®ar Owner 5k• ;I 1-1. ,,-, Address i . $1..;.�'irit�3 Tax Map ID 5Q- 3 O.! --S`t{9 "" VON Permit 101 -0r,�••GC.P`{'I war Phone —`_____ - VWCB Permit Location : _-T___ 7 VWCB ID 411111, — County — ' WeII Oata• wee General Informal; NI car •Orllting Method � c Dad.Com I ed 72" r-'1 Total Depth of Well O.r Depth to Bedre c '' 'r1. Z {GPM) Length of Test Static Water Lr•,6 Sttabtttz• Water Leve) Natural Flow{Rate) f mw Well Disinfect° , 0_ Olsingectant Used Amount Used `a`" Casing From -..1r ) To From To From ow' Size C i Z-a_M. , ,rte Size Material Size Material mw WeighVSchadute "CD WeighuSchadule Weight Schedule car Gravel Pack mw From ` _ From To From To way iroul / our prom ?— From • T Bore Hole Size 1, Bore Hole Size From To r Type _ Tore Hole Size ca Method I TY°, Typo •�" Method Method Nor *ow Water Zones or 5c nod Int_rvale From )0 D 1( From To From. To_ mw Mesh_Size Siam_ __ Mesh Size Diam Mesh Size Diem From __ _ From To From To — Mesh Size_ ;3rn _ _ Mesh Size Diam Mesh Size Diem are .. • Use Data ` rr Private Wett: c - - Agricultural Industrial Monitoring Public Wolf: - r Non Cornmunhy mw •mw • Abandonment Information • 441ka, Borod or Dug 1. Wells other than gored Wells Casing aomovt. Casing removed, Y or N? or It V. Depth to w ..., ,n9 w: removed: Depth to Which casing was removed: Deptn and Typo Applicable,depth(s),and type of graveVsand fill: aser Source of Fill! Source of gravel or sand: RentonM. Plugs: c _ From to Cement From to • From to Method of r.rms ••10. cation: mw • aw ww may mw FOSTER WELL UM? TEL :804-973-8838 Jul 09 ,01 14 :31 No .006 P .03 *Ey • - "kw . • • • •■•• ' yew " • mew • Drillers Log • Air Depth Dosatilitillrdl,Fdrrnealon ortedlinent • Remarks . • • vier -''.!#!rN ( c/a4 • s. a ver C ( 410, S , 17 6/AZ4 . 110. ftw *or mar Vow Are tiew 70. vow ? C.) Aller ler Aso Inv ler (User additional Sheets necessary) I certify (hal the in:- n her . irlia;i4f51 Ut this WeU WASS Installed and constructed in accordance with Om per mil an 4or• further that the well ;;o6 WL &I 03140.44041:',6,66611'kacaV;i60 I alio na,ordinances and laws. ler Name PC:" WELL & PUMP CO' INC Address 3; DRIVE • •• ••• oar C;' •TESVI ; ;• Phone LE( oar Drillers Si ;gnatu• . •. - ger Date r. Virginia convact.,,r, NIJITS:',,a 22.0c•al 4c1I.ch. • • low vi vor vow 111■0 iarr �_ .._ ... quir Water SUV ar.d/c r Sewage Disposal System Construction Permit Page I of 3 Commoriwealtii a Health Department Department of It, Identification Number: 101-01-0142 ALBEMARLE( 'L::I .,.'i'ARTMEN'F Tax Map Number: 58-302-603(W) vier General Information BP#: maw Water Sir-: ;vst Sewage Disposal System:VACANT LOT Based u., di . •disposal system construction permit filed in accordance with Section 2.13 E,of the Sewage Handling and ow Disposal i::. .ttic .)r: .c.i.,., 2.13 of the Private Well Regulations a construction permit is hereby issued to: Owner: S1C'.LI` I IL 3L i[ UERS Telephone: 804-962-2071 ""r'' Address: 122;NI • ',I; 1W. U,CIIARLOTTESVILLE,VA 22901 r For a T,,c S • .or Well to be constructed on/at Subdivision:! MMERIWETNER LANE `or Sec/Bk L •_.ui e:..:nated water use 600 gpd- 4 bedrooms NOTES: SEWAGE DISPOSAL SYSTEM INSPECTION RESULTS vow Water supply, . •7 .1.:.. i I Water supply location:Satisfactory yes no "`rr It. I GROUT CAP Tobei:- • 14 GY rr,,tt �. yr CASE, d °,et Cf`s 4VWr(1 ��� I ENS - -yr DATE 4,1Q V� vrr - 1 Aar WELL PLR, mew irw • Air low wr .ore irr v wr ' w airr .tor Ar rrr Mir IOW Miryr wrr irr Nally 'OW last liar view Page Number_ _ 3 Health Department 101.01-0142 vat Identification Number 'or Schematic r _isposal and/or water supply system and topographic features. shower trr'r,,, ;,•operty stowing any L^poprep features which may impact on the daslpn of the wad or sewage disposal system,including Iii, edging a,::„;, .cm oral systems and webs*thin 200 feel The echemetk drawing of the well cite or area and/or sswase disposal system shall show.r« • :station.conveyance system,and subsurface soil absorption system,reserve area,etc When a nonptd lc drinking water suppty Is to a T. ;kA on Alen 200 fast. " ?.D Th has been drawn on the attached copy of the sketch submitted with the application. VW ilea war r IIIC Well Permit Only . VW "— / id well driled on permit Cul de Sac ' ..47. To be abandoned. I .ar mow 32 7 t3% - 1 Air Slope tar 3` f S a .r 143= Proposed House .l lay Saar P I 0 i V MC II Point 2a__a- 55' r.r . 100't--x1'43' 6 f 127+ d ' 1-1- 11W al IV C v l i 1 \ 15% I s , 121 .r vie l I i 1 i t i rw• Air Not r .r This sewn )s „ilor water supply Is to be constructed as specified by this permit. This sown„ 3; _;I construction permit is null and void If(a)conditions aro changed from those shown on the ',aw application(L, x, ,re from those shown on the construction permit. ear No part of any i prod or used until Inspected local made if necessary,and approved,by the lo health department or n.. :x '..od by the local health dept. Any part of any Installation which has been covered prior to approval shall:. . w. ' y,upon the direction of the Depa nt. — ley i 1„r This Construction Date: '/l Issued by: Al-. .A4 ,i Permit Valid until 411W Environmental earth Specialist Date: _ Reviewed by: 09/09/2005 'r+ Environmental Health Supervisor • rut war err — *Mr • ""` Page Nurr` - of Health Department •it Identification Number 01-00-0647'._' Schemat' :rawi : se )osal andlor water supply system and topographic features. Aar Show the lot:. of the t ae, Q�y s tww showing any topographic ephlc fea urea which They Impact on the design of the well or sewage disposal system,including existing and'.., posed .s a :.,asal systems and wetts within 200 feet.The schemato drawing of the well site or area andlor sewage disposal system .Yr scut show sn., 'Inas.e. ant■ on,conveyance system,and subsurface soft absorption system reserve area,etc.When a nonpub➢c drkedrp water supply Is to Let. 'milled, .. :so: .•.:n wain 200 teal. air 0 The inf rmatic re Are .,s been drawn on the attached copy of the sketch submitted with the application. IOW THIS PERMIT ISSUED UNDER THE 2000 REGULATIONS r• VII , --( 6 I./`b -rdir /o( - 61 -011 Z. IOW iler 1 gar ( 5 :Well Area,Parallel to + Cul de Sac i i .:zgins20'From Culvert. t Install. Val" 3n-\ g a 4110,_ eee $ . or 5 Trenches � . teasel 20 I 42" Deep lealv I 95' Long I 3' Wide Proposed House ' � 1a� 1 D Centers .art PL stags 1 t On Contour!!! �r N. \ 107' VSO 43' Amp �7 G� 12T t \,15% < 1 i l 121' 'VW vlo `_ � � ' l l i ,-? 18 ' erur -- 1 +ar No` S vow This say dlsr c 'or water supply Is to be constructed as specified by this permit. +set . This sewa. spose .m. ronstructlon permit Is null and void if la)conditions are changed from those shown on the +re application; ,condit re c .m those shown on the construction permit. No part of ar,'Install. shat :or used until inspected,corrections made If necessary,and approved,by the local health air department -unless Ass' 1 by the local health dept. Any part of arty installation which has boo,covered prior to approval s: sue un: .1,i upon the direction of the Department. tar "' Date: 1'. ' "'1 Issued by: i , r , This Construction — — Y Permit Valid until En r•- mental Health Specialist """ Date: _ _ Reviewed by: 06/11/2002 Ian Environmental Health Supervisor low Imo aar .r Al i • "'r' Commonwealth of Virginia Uniform Water Well Completion Report 'rr Owner - rr- l-- N-6((4•),5 Tax Map ID --61 Address _ VDH Permit i i .7 Al r VWCB Permit Phone_ _ "" Location _ VWCB ID r County ` U k)2,yibi't LL, AY Iry • Well Data • Nio, Generai I •nati __ Drilling h.' ' Data Completed h{ -iu-OJ Total Depth of Well 26 Depth to : Yield 1 0 (GPM) Length of Test err Static V' - .;taL:.zod Water Level Natural Flow(Rate) !D Well D.,.. (' i,i si,.;octant Used Amount Used Nor Casing ,_ ,or From 't c "roni To From To Size ex .' ___ m: _ Size Material Size Material oar WeighvS_ a _ _ WeighvSchadi.le Weight/Schedule Ali Gr a vei ror =rom r ron,_ To From To Ali „o„ gout rrom -- From To .r bore H — From To Type _ Core Hole Size Bore Hole Size Type— - 'Yp, Type o r• Methoc _ ----- 1.,ett.c,d Met hod irr Water , From _ !_ __ From To From • To Ali Mesh r..es,t Sizo Diam Mesh Size Diam From From --_ To From To •rr Mesh c. _ t..es.r Size Diam Mesh Size ,..,Durst _ +ar ., ).- iv ti. 4110* • Use Data • JUL b 9 2001 ,r. Private . ..,I Age„.JItcral Industrial Monitoring ENVIRONMENTAL HEALTH Public W. ,on Non Community Air VW • Abandonment Information • 'II Bored . Wells other than Bored Wells ow Casing • •a, Casing removed, Y or N? II Y, D • • •h i c _)v cad: Depth to which casing was removed: Air Depth ` o: Applicable,depth(s), and type of gravel/sand fill: • Source ,• _ '— ar Source - Source of gravel or sand: From o Cement: From to From to • °r' Method c: ^am. ,ii', .:ion: Air V +ar IIIW lir yr Mew .r. _ 9•1111111111a'AIL.y, • r.. ' Drillers Log • ior Depth Doscriv.ion of Formation r Sedi nt Remarks err *410, I J - r. f . Aar 3.0 3c, (.// 3O vor Aller IOW • : 4111. • CtD I 6/0 — 2 Now 440, , New wr (User additional Sheets if necessary) '411r I certify that :7e in .ad here tt.,a and that this well was installed and constructed in accordance with the permit and further that t .e we .11 applic;..ae state and local regulations, ordinances and laws. +.r Name FOS PUMP C..) LtC Address 37( Jtt1V1. CH/ ))VA I Phone (8(' ,�, Drillers Sigr. re ��QQ� Date F STEPtl7 .L' 4, PUMP CO INC wry • Virginia Ccr'•aetn )r 271, ( I5945A mow Vi 111r 111r aoso..o.. s a.r war NW r gar VII Appendix C Environmental Data Resources Report IIII III/ MOW VW VI VP WIII two Vii✓ vow Imo Mechums Trestle 4294 Three Notched Rd .r Charlottesville, VA 22901 .r► Inquiry Number: 4182090.2s January 14, 2015 rwr e e e The EDR Radius Map TM Report with GeoCheck® 4. G 6 Armstrong Road,4th floor CEDR® Environmental Data Resources Inc Shelton,CT 06484 Toll Free:800 352 0050 www.edrnet.com FORM-LBC-CCA IOW TABLE OF CONTENTS SECTION PAGE moo Executive Summary_ _ ES1 Overview Map_ 2 Detail Map_ 3 Ary Map Findings Summary 4 lisv Map Findings_ 7 Orphan Summary_ 8 Government Records Searched/Data Currency Tracking_ GR-1 `•r GEOCHECK ADDENDUM • Physical Setting Source Addendum_ A-1 may „o Physical Setting Source Summary A-2 „s, Physical Setting SSURGO Soil Map _ A-5 ;,r, Physical Setting Source Map_ A-25 Physical Setting Source Map Findings_ A-27 I,„ Physical Setting Source Records Searched PSGR-1 Thank you for your business. — Please contact EDR at 1-800-352-0050 with any questions or comments. Amy Nor �.w w✓ Disclaimer-Copyright and Trademark Notice This Report contains certain information obtained from a variety of pgublic and other sources reasonably availablee to Environmental Data Amy other sources.NO WARRANTY EXPRESSED OR IMPLIED,IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT.ENVIRONMENTAL DATA from DATA RESOURCES,INC.SPECIFICALLY DISCLAIMS THE MAKING OF ANY SUCH WARRANTIES,INCLUDING WITHOUT LIMITATION, MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE.ALL RISK IS ASSUMED BY THE USER.IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES,INC.BE LIABLE TO ANYONE,WHETHER ARISING OUT OF ERRORS OR OMISSIONS,NEGLIGENCE, vow ACCIDENT OR ANY OTHER CAUSE,FOR ANY LOSS OF DAMAGE,INCLUDING,WITHOUT LIMITATION,SPECIAL,INCIDENTAL, CONSEQUENTIAL,OR EXEMPLARY DAMAGES.ANY LIABILITY ON THE PART OF ENVIRONMENTAL DATA RESOURCES,INC.IS STRICTLY — LIMITED TO A REFUND OF THE AMOUNT PAID FOR THIS REPORT.Purchaser accepts this Report"AS IS".Any analyses,estimates,ratings, environmental risk levels or risk codes provided in this Report are provided for illustrative purposes only,and are not intended to provide,nor rrr should they be interpreted as providing any facts regarding,or prediction or forecast of,any environmental risk for any property.Only a Phase I Environmental Site Assessment performed by an environmental professional can provide information regarding the environmental risk for any err property.Additionally,the information provided in this Report is not to be construed as legal advice. Copyright 2015 by Environmental Data Resources, Inc.All rights reserved.Reproduction in any media or format,in whole low or in part,of any report or map of Environmental Data Resources, Inc.,or its affiliates,is prohibited without prior written permission. EDR and its logos(including Sanborn and Sanborn Map)are trademarks of Environmental Data Resources, Inc.or its affiliates.All other "r trademarks used herein are the property of their respective owners. ter+ TC4182090.2s Page 1 New r vow f.r .r Asir EXECUTIVE SUMMARY `11r NNW low A search of available environmental records was conducted by Environmental Data Resources, Inc(EDR). wort The report was designed to assist parties seeking to meet the search requirements of EPA's Standards and Practices for All Appropriate Inquiries (40 CFR Part 312), the ASTM Standard Practice for Art Environmental Site Assessments (E 1527-13) or custom requirements developed for the evaluation of environmental risk associated with a parcel of real estate. wr TARGET PROPERTY INFORMATION Aar rrr ADDRESS 4294 THREE NOTCHED RD low ALBEMARLE County, VA 22901 mow COORDINATES velly Latitude(North): 38.0623000-38°3'44.28" vrr Longitude(West): 78.6489000-78°38'56.04" Universal Tranverse Mercator: Zone 17 UTM X(Meters): 706264.8 UTM Y(Meters): 4215131.5 'rr' Elevation: 504 ft. above sea level vow USGS TOPOGRAPHIC MAP ASSOCIATED WITH TARGET PROPERTY vow Target Property Map: 38078-A6 CROZET, VA Aar Most Recent Revision: 1997 err+ AERIAL PHOTOGRAPHY IN THIS REPORT Portions of Photo from: 20120831 Source: USDA Nrr "r` TARGET PROPERTY SEARCH RESULTS itont The target property was not listed in any of the databases searched by EDR. 'rr err *ow DATABASES WITH NO MAPPED SITES NOY No mapped sites were found in EDR's search of available ("reasonably ascertainable ") government records either on the target property or within the search radius around the target property for the following databases: wr wr STANDARD ENVIRONMENTAL RECORDS wr Federal NPL site list NPL National Priority List +.r wr 41.9 vrr TC4182090.2s EXECUTIVE SUMMARY 1 Now VOW vew EXECUTIVE SUMMARY Proposed NFL Proposed National Priority List Sites NPL LIENS Federal Superfund Liens `ay Federal Delisted NPL site list .�► Delisted NPL National Priority List Deletions Amy Federal CERCLIS list — CERCLIS Comprehensive Environmental Response, Compensation, and Liability Information System FEDERAL FACILITY Federal Facility Site Information listing 'o' Federal CERCLIS NFRAP site List IOW CERC-NFRAP CERCLIS No Further Remedial Action Planned "er Federal RCRA CORRACTS facilities list rn• CORRACTS Corrective Action Report vow Federal RCRA non-CORRACTS TSD facilities list RCRA-TSDF RCRA-Treatment,Storage and Disposal mew Federal RCRA generators list err RCRA-LQG RCRA- Large Quantity Generators RCRA-SQG RCRA-Small Quantity Generators RCRA-CESQG RCRA-Conditionally Exempt Small Quantity Generator y.r "o Federal institutional controls/engineering controls registries US ENG CONTROLS Engineering Controls Sites List US INST CONTROL Sites with Institutional Controls LUCIS Land Use Control Information System Federal ERNS list vo, ERNS Emergency Response Notification System `or State-and tribal-equivalent CERCLIS — SHWS This state does not maintain a SHWS list. See the Federal CERCLIS list and Federal NPL list. New �, State and tribal landfill and/or solid waste disposal site lists SWF/LF Solid Waste Management Facilities Aviv wr State and tribal leaking storage tank lists LUST Leaking Underground Storage Tank Tracking Database Amy LTANKS Leaking Petroleum Storage Tanks .100 INDIAN LUST Leaking Underground Storage Tanks on Indian Land State and tribal registered storage tank lists -r. UST Registered Petroleum Storage Tanks Now vire low TC4182090.2s EXECUTIVE SUMMARY 2 wu► *ar EXECUTIVE SUMMARY err AST Registered Petroleum Storage Tanks ®„r INDIAN UST Underground Storage Tanks on Indian Land FEMA UST Underground Storage Tank Listing State and tribal institutional control/engineering control registries ENG CONTROLS Engineering Controls Sites Listing "011/ INST CONTROL Voluntary Remediation Program Database ter. State and tribal voluntary cleanup sites INDIAN VCP Voluntary Cleanup Priority Listing VCP Voluntary Remediation Program vow and tribal Brownfields sites BROWNFIELDS Brownfields Site Specific Assessments ADDITIONAL ENVIRONMENTAL RECORDS vow Local Brownfield lists �r US BROWNFIELDS A Listing of Brownfields Sites 1111W Local Lists of Landfill/Solid Waste Disposal Sites „i, DEBRIS REGION 9 Torres Martinez Reservation Illegal Dump Site Locations ODI Open Dump Inventory Aar INDIAN ODI Report on the Status of Open Dumps on Indian Lands err Local Lists of Hazardous waste/Contaminated Sites 4,w US CDL Clandestine Drug Labs US HIST CDL National Clandestine Laboratory Register ern — Local Land Records �, LIENS 2 CERCLA Lien Information Records of Emergency Release Reports — HMIRS Hazardous Materials Information Reporting System SPILLS Prep/Spills Database Listing vow SPILLS 90 SPILLS 90 data from FirstSearch �r Other Ascertainable Records "'" RCRA NonGen/NLR RCRA-Non Generators/No Longer Regulated DOT OPS Incident and Accident Data Now DOD Department of Defense Sites FUDS Formerly Used Defense Sites CONSENT Superfund(CERCLA)Consent Decrees — ROD Records Of Decision UMTRA_ Uranium Mill Tailings Sites Air Now yr TC4182090.2s EXECUTIVE SUMMARY 3 law Now •r. lir EXECUTIVE SUMMARY US MINES Mines Master Index File err IRIS Toxic Chemical Release Inventory System TSCA_ Toxic Substances Control Act woo FITS FIFRA/TSCA Tracking System-FIFRA(Federal Insecticide, Fungicide, & Rodenticide Act)/TSCA(Toxic Substances Control Act) 'ter HIST FTTS FIFRA/TSCA Tracking System Administrative Case Listing SSTS Section 7 Tracking Systems ICIS Integrated Compliance Information System PADS PCB Activity Database System MLTS Material Licensing Tracking System RADINFO Radiation Information Database FINDS Facility Index System/Facility Registry System 440„ RAATS RCRA Administrative Action Tracking System RMP Risk Management Plans Air UIC Underground Injection Control Wells DRYCLEANERS Drycleaner List v r ENF Enforcement Actions Data NPDES Comprehensive Environmental Data System vow AIRS Permitted Airs Facility List TIER 2 Tier 2 Information Listing INDIAN RESERV Indian Reservations SCRD DRYCLEANERS State Coalition for Remediation of Drycleaners Listing PCB TRANSFORMER PCB Transformer Registration Database law Financial Assurance Financial Assurance Information Listing US FIN ASSUR Financial Assurance Information EPA WATCH LIST EPA WATCH LIST COAL ASH Coal Ash Disposal Sites US AIRS Aerometric Information Retrieval System Facility Subsystem COAL ASH DOE Steam-Electric Plant Operation Data vrr 2020 COR ACTION 2020 Corrective Action Program List LEAD SMELTERS Lead Smelter Sites PRP Potentially Responsible Parties COAL ASH EPA Coal Combustion Residues Surface Impoundments List v.r EDR HIGH RISK HISTORICAL RECORDS EDR Exclusive Records Aro EDR MGP EDR Proprietary Manufactured Gas Plants Amy EDR US Hist Auto Stat .EDR Exclusive Historic Gas Stations EDR US Hist Cleaners EDR Exclusive Historic Dry Cleaners ®rr EDR RECOVERED GOVERNMENT ARCHIVES Air Exclusive Recovered Govt.Archives RGA LF Recovered Government Archive Solid Waste Facilities List low RGA LUST Recovered Government Archive Leaking Underground Storage Tank .rr — SURROUNDING SITES:SEARCH RESULTS aro Surrounding sites were not identified. Unmappable(orphan)sites are not considered in the foregoing analysis. wr 9rr. w imp TC4182090.2s EXECUTIVE SUMMARY 4 lir v®r► m.r EXECUTIVE SUMMARY Due to poor or inadequate address information,the following sites were not mapped.Count:9 records. Site Name Database(s) war MOORES BUILDING SUPPLY LUST, LTANKS 4111, VIRGINIA LAND CO. LUST, LTANKS BLACK INDUSTRIES LUST,SPILLS +ir A.T.WILLIAMS OIL CO. LUST,LTANKS TABOR PRESBYTERIAN CHURCH LUST, LTANKS SPRINT-CROZET LUST,LTANKS LICKINGHOLE CREEK PUMP STATION(CR LUST,LTANKS TOWN&COUNTRY MOTOR LODG LTANKS TOWN&COUNTRY MOTOR LODGE LTANKS vwr +wr vow wr +ir err. wr VOW mwr 41r rr .4110, w0, wrr IOW .rrr 41111 «r TC4182090 2s EXECUTIVE SUMMARY 5 it Parr Ilir OVERVIEW MAP - 4182090.2S it 41-41' Arimiffs ,,s," ..:„.,l'''' kof -►rti • • .4. . 7. • ♦ -1 8 •• , aF_ .. . • , R f r .. ' . - 'lrill""lik-' : ..i,_ ' . l yo r 4110 . • } k _ . r J h e • 4f " ' 't.r n r . t • ., l �' .. . I. • M ,a ,Pit @J • y,i M• • * Target Property o 1/4 1/2 1 Miles • A Sites at elevations higher than ■••■•■ or equal to the target property -= Indian Reservations BIA • • Sites at elevations lower than ;\ Oil&Gas pipelines from USGS �I the target property • A Manufactured Gas Plants 100-year flood zone LLi500-year flood zone National Priority List Sites ��I Dept.Defense Sites II National Wetland Inventory • This report includes Interactive Map Layers to display and/or hide map information.The legend includes only those icons for the • default map view. • SITE NAME: Mechums Trestle CLIENT: HydroGeo Environmental LLC I, ADDRESS: 4294 Three Notched Rd CONTACT: Ernest Beasley • I Charlottesville VA 22901 INQUIRY#: 4182090.2s LAT/LONG: 38.0623/78.6489 DATE: January 14,2015 4:39 pm 416„ I Copyright cc 2015 EDR,Inc ct 2010 Tele Atlas Rel 07/2009. 111 • • DETAIL MAP - 4182090.2S • • ✓ f _ ' . y}. ' ar k,• , 0 MO • - , . ir"?. .i.;.i Xi* , , * 7 * % Iry-` i:'A ,-.` A •' lir e.t ttt' a 0 s ..",• .#:-. ''.., ;II ....1 1... ,,i/,‘006, *,:. 4/- , 14 1 % . • ..i. , , © ;" sue- _a -•--•.. ., s_.- /- •' , 0. • 1000,- '-.*. '* 7-stari..,:.:it.:#1r.:. / -1411:1011 • • . • • • • Atot+ • • * Target Property 0 1/16 11 1/4 Mlles i• A Sites at elevations higher than or equal to the target property `-I Indian Reservations BIA • • Sites at elevations lower than /\/ Oil&Gas pipelines from USGS • L the target property Manufactured Gas Plants 100 year flood zone • 500-year flood zone Sensitive Receptors 1.• National Wetland Inventory 0 National Priority List Sites Dept.Defense Sites This report includes Interactive Map Layers to • display and/or hide map information.The legend includes only those icons for the _ default map view. SITE NAME: Mechums Trestle CLIENT: HydroGeo Environmental LLC ADDRESS: 4294 Three Notched Rd CONTACT: Ernest Beasley • Charlottesville VA 22901 INQUIRY#: 4182090.2s • LAT/LONG: 38.0623/78.6489 DATE: January 14,2015 4:40 pm 6 Copyright Cn 2015 EDR,Inc co 2010 Tele Atlas Rel 07/2009. maw Iftiov wr' MAP FINDINGS SUMMARY .ems Search N r Distance Target Total Database (Miles) Property <1/8 1/8- 1/4 1/4- 1/2 1/2- 1 >1 Plotted Mr err STANDARD ENVIRONMENTAL RECORDS low Federal NPL site list vow NPL 1.000 0 0 0 0 NR 0 d.. Proposed NPL 1.000 0 0 0 0 NR 0 NPL LIENS TP NR NR NR NR NR 0 41111" Federal Delisted NPL site list V' Delisted NPL 1.000 0 0 0 0 NR 0 Federal CERCLIS list CERCLIS 0.500 0 0 0 NR NR 0 lir FEDERAL FACILITY 0.500 0 0 0 NR NR 0 it Federal CERCLIS NFRAP site List „e, CERC-NFRAP 0.500 0 0 0 NR NR 0 Federal RCRA CORRACTS facilities list vow CORRACTS 1.000 0 0 0 0 NR 0 .r Federal RCRA non-CORRACTS TSD facilities list imr RCRA-TSDF 0.500 0 0 0 NR NR 0 0, Federal RCRA generators list RCRA-LOG 0.250 0 0 NR NR NR 0 "" RCRA-SQG 0.250 0 0 NR NR NR 0 Amy, RCRA-CESQG 0.250 0 0 NR NR NR 0 Federal institutional controls/ Army engineering controls registries miry US ENG CONTROLS 0.500 0 0 0 NR NR 0 US INST CONTROL 0.500 0 0 0 NR NR 0 wr LUCIS 0.500 0 0 0 NR NR 0 Federal ERNS list Nue ERNS TP NR NR NR NR NR 0 aer State-and tribal-equivalent CERCLIS — SHWS N/A N/A N/A N/A N/A N/A N/A weir State and tribal landfill and/or solid waste disposal site lists wr. SWF/LF 0.500 0 0 0 NR NR 0 Aw State and tribal leaking storage tank lists LUST 0.500 0 0 0 NR NR 0 LTANKS 0.500 0 0 0 NR NR 0 41■•• INDIAN LUST 0.500 0 0 0 NR NR 0 Nov State and tribal registered storage tank lists NW UST 0.250 0 0 NR NR NR 0 war VOW 'weir TC4182090.2s Page 4 VP, wr Ar. NOW Vr , MAP FINDINGS SUMMARY Search wkr Distance Target Total Database (Miles) Property <1/8 1/8-1/4 1/4- 1/2 1/2- 1 >1 Plotted 411, AST 0.250 0 0 NR NR NR 0 liWr INDIAN UST 0.250 0 0 NR NR NR 0 411/ FEMA UST 0.250 0 0 NR NR NR 0 State and tribal institutional — control/engineering control registries IOW ENG CONTROLS 0.500 0 0 0 NR NR 0 INST CONTROL 0.500 0 0 0 NR NR 0 Air State and tribal voluntary cleanup sites +rr INDIAN VCP 0.500 0 0 0 NR NR 0 VCP 0.500 0 0 0 NR NR 0 wr State and tribal Brown fields sites Aso BROWNFIELDS 0.500 0 0 0 NR NR 0 vair ADDITIONAL ENVIRONMENTAL RECORDS Aar Local Brownfield lists rrr US BROWNFIELDS 0.500 0 0 0 NR NR 0 �`" Local Lists of Landfill/Solid • 411P, Waste Disposal Sites DEBRIS REGION 9 0.500 0 0 0 NR NR 0 Aa" ODI 0.500 0 0 0 NR NR 0 INDIAN ODI 0.500 0 0 0 NR NR 0 lr Local Lists of Hazardous waste/ yip Contaminated Sites US CDL TP NR NR NR NR NR 0 US HIST CDL TP NR NR NR NR NR 0 OW Local Land Records +rr LIENS 2 TP NR NR NR NR NR 0 Records of Emergency Release Reports HMIRS TP NR NR NR NR NR 0 `"'" SPILLS TP NR NR NR NR NR 0 SPILLS 90 TP NR NR NR NR NR 0 wr Other Ascertainable Records vialy RCRA NonGen/NLR 0.250 0 0 NR NR NR 0 ,us DOT OPS TP NR NR NR NR NR 0 DOD 1.000 0 0 0 0 NR 0 .,r, FUDS 1.000 0 0 0 0 NR 0 CONSENT 1.000 0 0 0 0 NR 0 .r ROD 1.000 0 0 0 0 NR 0 UMTRA 0.500 0 0 0 NR NR 0 law US MINES 0.250 0 0 NR NR NR 0 TRIS TP NR NR NR NR NR 0 .rr VW %r TC4182090.2s Page 5 law VW iiv +r MAP FINDINGS SUMMARY iwr Aar Search *my Distance Target Total Database (Miles) Property <1/8 1/8-1/4 1/4- 1/2 1/2- 1 >1 Plotted wr TSCA TP NR NR NR NR NR 0 `1Q1r FTTS TP NR NR NR NR NR 0 low HIST FTTS TP NR NR NR NR NR 0 SSTS TP NR NR NR NR NR 0 r,r ICIS TP NR NR NR NR NR 0 PADS TP NR NR NR NR NR 0 low MLTS TP NR NR NR NR NR 0 RADINFO TP NR NR NR NR NR 0 111111r FINDS TP NR NR NR NR NR 0 RAATS TP NR NR NR NR NR 0 wow RMP TP NR NR NR NR NR 0 UIC TP NR NR NR NR NR 0 ior DRYCLEANERS 0.250 0 0 NR NR NR 0 ENF TP NR NR NR NR NR 0 Apr NPDES TP NR NR NR NR NR 0 .wr AIRS TP NR NR NR NR NR 0 TIER 2 TP NR NR NR NR NR 0 ,, INDIAN RESERV 1.000 0 0 0 0 NR 0 SCRD DRYCLEANERS 0.500 0 0 0 NR NR 0 Aar PCB TRANSFORMER TP NR NR NR NR NR 0 Financial Assurance TP NR NR NR NR NR 0 vnr US FIN ASSUR TP NR NR NR NR NR 0 EPA WATCH LIST TP NR NR NR NR NR 0 lir COAL ASH 0.500 0 0 0 NR NR 0 US AIRS TP NR NR NR NR NR 0 'w'` COAL ASH DOE TP NR NR NR NR NR 0 2020 COR ACTION 0.250 0 0 NR NR NR 0 i"` LEAD SMELTERS TP NR NR NR NR NR 0 PRP TP NR NR NR NR NR 0 Air COAL ASH EPA 0.500 0 0 0 NR NR 0 +irr EDR HIGH RISK HISTORICAL RECORDS +rr wr EDR Exclusive Records EDR MGP 1.000 0 0 0 0 NR 0 A►' EDR US Hist Auto Stat 0.250 0 0 NR NR NR 0 EDR US Hist Cleaners 0.250 0 0 NR NR NR 0 err EDR RECOVERED GOVERNMENT ARCHIVES ,ir Exclusive Recovered Govt.Archives ,im RGA LF TP NR NR NR NR NR 0 RGA LUST TP NR NR NR NR NR 0 irr - NOTES: malw TP-Target Property NR=Not Requested at this Search Distance AIM" Sites may be listed in more than one database 'ter N/A=This State does not maintain a SHWS list. See the Federal CERCLIS list. VW .r. +rr ANW TC4182090.2s Page 6 law v.. NU/ Map ID MAP FINDINGS +.. Direction - Distance EDR ID Number mar Elevation Site Database(s) EPA ID Number rr ar NO SITES FOUND +N. arr err ter► +r VOW +r► yr +rr IOW ar ASV yr +.r r yr 411► TC4182090.2s Page 7 41r• ANY 4111110` A Y Y J Y Y Y Y Q Q J Q Q Q Q Alow J CO J U) CO J J J a H Z H H H Z H F 0 J J J J J J J J " ° I O O O 0, a) O 0) CN+) a rn a) rn rn N N N N N N N CO — d CL NSW CT (6 CO 111, 0 N CA 0 CO Now N U rr�r H U) yW W U) w W °c °v L'i.1 CD N �� O N N Q N H N N Lo LL1 H H N } — H H O H � H O O t w- (1) ¢ 0 0 0 2 0 2 ¢ 0) 1110, } - Q Q i® 2 U 2 h✓ w g C7 C7 2 H — = O O cc cn D VAr p a H O U 0 (n 2 O 2 Q U CC LU '1M" Z ¢ w 2 H CC LIJ H `�✓ - 2 Z 0 2 2 U O w CC m O J E J Cr N V O "�/►' E w ° Q Z J ° tci W Z Z Y ?� Z 2 Z Z ANY g) 0 0 CC(I) 2 HH > co Q HO H co J O (co V V O O n ^ a0c U7 0 N H. r) H 0 CO V 0 0 (OO CO N 0 COO 0) 0 0 + V N V V W O O O O O O 0 W 0) 0) 0) 0) 0) 0) 0) 0) 0) Y✓ W W W W W J J J J J _J - J J J J J J 0) > > > > > > 0) 0) () 0) () 0) o W W W W W W I H r r r r H rn O O O O O O W w W — -J _I CC ¢ ¢ N N N o 2 2 2 2 2 2 ¢ ¢ ¢ 0 CU 0 0 0 0 0 0 0 0 0 Inky S w.` GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING To maintain currency of the following federal and state databases,EDR contacts the appropriate governmental agency low on a monthly or quarterly basis,as required. Number of Days to Update:Provides confirmation that EDR is reporting records that have been updated within 90 days arrr from the date the government agency made the information available to the public. STANDARD ENVIRONMENTAL RECORDS va, Federal NPL site list low NPL: National Priority List National Priorities List(Superfund).The NPL is a subset of CERCLIS and identifies over 1,200 sites for priority ir► cleanup under the Superfund Program.NPL sites may encompass relatively large areas.As such,EDR provides polygon coverage for over 1,000 NPL site boundaries produced by EPA's Environmental Photographic Interpretation Center — (EPIC)and regional EPA offices. err, Date of Government Version:09/29/2014 Source: EPA Date Data Arrived at EDR:10/08/2014 Telephone: N/A mow Date Made Active in Reports:11/17/2014 Last EDR Contact:01/08/2015 Number of Days to Update:40 Next Scheduled EDR Contact:04/20/2015 ger Data Release Frequency:Quarterly — NPL Site Boundaries egg Sources: EPA's Environmental Photographic Interpretation Center(EPIC) +rr Telephone:202-564-7333 — EPA Region 1 EPA Region 6 Telephone 617-918-1143 Telephone:214-655-6659 rrr EPA Region 3 EPA Region 7 AMY Telephone 215-814-5418 Telephone:913-551-7247 EPA Region 4 EPA Region 8 Telephone 404-562-8033 Telephone:303-312-6774 `e' EPA Region 5 EPA Region 9 Telephone 312-886-6686 Telephone:415-947-4246 ew EPA Region 10 ww Telephone 206-553-8665 — Proposed NPL: Proposed National Priority List Sites A site that has been proposed for listing on the National Priorities List through the issuance of a proposed rule in the Federal Register.EPA then accepts public comments on the site,responds to the comments,and places on the NPL those sites that continue to meet the requirements for listing. Date of Government Version:09/29/2014 Source: EPA low Date Data Arrived at EDR:10/08/2014 Telephone: N/A Date Made Active in Reports:11/17/2014 Last EDR Contact:01/08/2015 'or'' Number of Days to Update:40 Next Scheduled EDR Contact:04/20/2015 Data Release Frequency:Quarterly ger NPL LIENS: Federal Superfund Liens Federal Superfund Liens. Under the authority granted the USEPA by CERCLA of 1980,the USEPA has the authority err to file liens against real property in order to recover remedial action expenditures or when the property owner received notification of potential liability.USEPA compiles a listing of filed notices of Superfund Liens. Date of Government Version: 10/15/1991 Source: EPA Date Data Arrived at EDR:02/02/1994 Telephone: 202-564-4267 w Date Made Active in Reports:03/30/1994 Last EDR Contact:08/15/2011 rir Number of Days to Update:56 Next Scheduled EDR Contact:11/28/2011 Data Release Frequency:No Update Planned low "M` TC4182090.2s Page GR-1 wr 4.r GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Federal Delisted NPL site list vir DELISTED NPL: National Priority List Deletions "o` The National Oil and Hazardous Substances Pollution Contingency Plan(NCP)establishes the criteria that the EPA uses to delete sites from the NPL. In accordance with 40 CFR 300.425.(e),sites may be deleted from the err NPL where no further response is appropriate. +r' Date of Government Version:09/29/2014 Source: EPA Date Data Arrived at EDR:10/08/2014 Telephone: N/A low Date Made Active in Reports:11/17/2014 Last EDR Contact:01/08/2015 Number of Days to Update:40 Next Scheduled EDR Contact:04/20/2015 vir Data Release Frequency:Quarterly mar Federal CERCLIS list Aar CERCLIS: Comprehensive Environmental Response,Compensation,and Liability Information System Aar CERCLIS contains data on potentially hazardous waste sites that have been reported to the USEPA by states,municipalities, private companies and private persons,pursuant to Section 103 of the Comprehensive Environmental Response,Compensation, wre and Liability Act(CERCLA).CERCLIS contains sites which are either proposed to or on the National Priorities List(NPL)and sites which are in the screening and assessment phase for possible inclusion on the NPL. gar Date of Government Version:10/25/2013 Source: EPA „rr,. Date Data Arrived at EDR:11/11/2013 Telephone: 703-412-9810 Date Made Active in Reports:02/13/2014 Last EDR Contact:01/09/2015 — Number of Days to Update:94 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Quarterly Nor FEDERAL FACILITY: Federal Facility Site Information listing A listing of National Priority List(NPL)and Base Realignment and Closure(BRAG)sites found in the Comprehensive Environmental Response,Compensation and Liability Information System(CERCLIS)Database where EPA Federal Facilities Nor Restoration and Reuse Office is involved in cleanup activities. �r Date of Government Version:07/21/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:10/07/2014 Telephone: 703-603-8704 mow Date Made Active in Reports:10/20/2014 Last EDR Contact:01/09/2015 Number of Days to Update:13 Next Scheduled EDR Contact:04/20/2015 411W Data Release Frequency:Varies Am* Federal CERCLIS NFRAP site List row CERCLIS-NFRAP: CERCLIS No Further Remedial Action Planned Archived sites are sites that have been removed and archived from the inventory of CERCLIS sites.Archived status indicates that,to the best of EPA's knowledge,assessment at a site has been completed and that EPA has determined iter no further steps will be taken to list this site on the National Priorities List(NPL),unless information indicates this decision was not appropriate or other considerations require a recommendation for listing at a later time. 'r This decision does not necessarily mean that there is no hazard associated with a given site;it only means that, based upon available information,the location is not judged to be a potential NPL site. Date of Government Version:10/25/2013 Source: EPA Date Data Arrived at EDR:11/11/2013 Telephone: 703-412-9810 Date Made Active in Reports:02/13/2014 Last EDR Contact:01/09/2015 ro Number of Days to Update:94 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Quarterly var Federal RCRA CORRACTS facilities list vsr CORRACTS: Corrective Action Report CORRACTS identifies hazardous waste handlers with RCRA corrective action activity. vow vior lor 11114 4IIr *Mir TC4182090.2s Page GR-2 GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Date of Government Version:06/10/2014 Source: EPA Nor Date Data Arrived at EDR:07/02/2014 Telephone: 800-424-9346 Date Made Active in Reports:09/18/2014 Last EDR Contact:12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Quarterly Arw 1111, Federal RCRA non-CORRACTS TSD facilities list ANY RCRA-TSDF: RCRA-Treatment,Storage and Disposal RCRAInfo is EPA's comprehensive information system,providing access to data supporting the Resource Conservation �wr and Recovery Act(RCRA)of 1976 and the Hazardous and Solid Waste Amendments(HSWA)of 1984.The database includes selective information on sites which generate,transport,store,treat and/or dispose of hazardous waste ow as defined by the Resource Conservation and Recovery Act(RCRA).Transporters are individuals or entities that move hazardous waste from the generator offsite to a facility that can recycle,treat,store,or dispose of the — waste.TSDFs treat,store,or dispose of the waste. vire— Date of Government Version:06/10/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:07/02/2014 Telephone: 800-438-2474 ler Date Made Active in Reports:09/18/2014 Last EDR Contact:12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 AMY Data Release Frequency:Quarterly e Federal RCRA generators list vrr RCRA-LQG: RCRA-Large Quantity Generators RCRAInfo is EPA's comprehensive information system,providing access to data supporting the Resource Conservation mar and Recovery Act(RCRA)of 1976 and the Hazardous and Solid Waste Amendments(HSWA)of 1984.The database includes selective information on sites which generate,transport,store,treat and/or dispose of hazardous waste isor as defined by the Resource Conservation and Recovery Act(RCRA).Large quantity generators(LQGs)generate ww over 1,000 kilograms(kg)of hazardous waste,or over 1 kg of acutely hazardous waste per month. Date of Government Version:06/10/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:07/02/2014 Telephone: 800-438-2474 Date Made Active in Reports:09/18/2014 Last EDR Contact: 12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Quarterly — RCRA-SQG: RCRA-Small Quantity Generators RCRAInfo is EPA's comprehensive information system,providing access to data supporting the Resource Conservation and Recovery Act(RCRA)of 1976 and the Hazardous and Solid Waste Amendments(HSWA)of 1984.The database includes selective information on sites which generate,transport,store,treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act(RCRA).Small quantity generators(SQGs)generate between 100 kg and 1,000 kg of hazardous waste per month. Amor Date of Government Version:06/10/2014 Source: Environmental Protection Agency yr Date Data Arrived at EDR:07/02/2014 Telephone: 800-438-2474 Date Made Active in Reports:09/18/2014 Last EDR Contact:12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Quarterly RCRA-CESQG: RCRA-Conditionally Exempt Small Quantity Generators RCRAInfo is EPA's comprehensive information system,providing access to data supporting the Resource Conservation and Recovery Act(RCRA)of 1976 and the Hazardous and Solid Waste Amendments(HSWA)of 1984.The database includes selective information on sites which generate,transport,store,treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act(RCRA).Conditionally exempt small quantity generators (CESQGs)generate less than 100 kg of hazardous waste,or less than 1 kg of acutely hazardous waste per month. Date of Government Version:06/10/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:07/02/2014 Telephone: 800-438-2474 Date Made Active in Reports:09/18/2014 Last EDR Contact: 12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 vow Data Release Frequency:Varies VOW yr *or• mrr Ai. TC4182090.2s Page GR-3 mow ftle r.r GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Vior Federal institutional controls/engineering controls registries +�r US ENG CONTROLS: Engineering Controls Sites List "o' A listing of sites with engineering controls in place. Engineering controls include various forms of caps,building foundations,liners,and treatment methods to create pathway elimination for regulated substances to enter environmental media or effect human health. vow Date of Government Version:09/18/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:09/19/2014 Telephone: 703-603-0695 `o` Date Made Active in Reports:10/20/2014 Last EDR Contact:12/03/2014 Number of Days to Update:31 Next Scheduled EDR Contact:03/16/2015 gai` Data Release Frequency:Varies yr US INST CONTROL: Sites with Institutional Controls wrr A listing of sites with institutional controls in place. Institutional controls include administrative measures, such as groundwater use restrictions,construction restrictions,property use restrictions,and post remediation ,ow care requirements intended to prevent exposure to contaminants remaining on site.Deed restrictions are generally required as part of the institutional controls. Date of Government Version:09/18/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:09/19/2014 Telephone: 703-603-0695 Ayr Date Made Active in Reports:10/20/2014 Last EDR Contact:12/03/2014 Number of Days to Update:31 Next Scheduled EDR Contact:03/16/2015 ftw Data Release Frequency:Varies vow LUCIS: Land Use Control Information System *of LUCIS contains records of land use control information pertaining to the former Navy Base Realignment and Closure properties. vr� Date of Government Version:08/29/2014 Source: Department of the Navy vair Date Data Arrived at EDR:10/09/2014 Telephone: 843-820-7326 Date Made Active in Reports:10/20/2014 Last EDR Contact:11/17/2014 Number of Days to Update:11 Next Scheduled EDR Contact:03/02/2015 Data Release Frequency:Varies vir Federal ERNS list VIM ERNS: Emergency Response Notification System Emergency Response Notification System.ERNS records and stores information on reported releases of oil and hazardous yr substances. Date of Government Version:09/29/2014 Source: National Response Center, United States Coast Guard Date Data Arrived at EDR:09/30/2014 Telephone: 202-267-2180 Date Made Active in Reports:11/06/2014 Last EDR Contact: 12/29/2014 '— Number of Days to Update:37 Next Scheduled EDR Contact:04/13/2015 yr Data Release Frequency:Annually Barr State-and tribal-equivalent CERCLIS SHWS: This state does not maintain a SHWS list.See the Federal CERCLIS list and Federal NPL list. State Hazardous Waste Sites.State hazardous waste site records are the states'equivalent to CERCLIS.These sites or may or may not already be listed on the federal CERCLIS list.Priority sites planned for cleanup using state funds (state equivalent of Superfund)are identified along with sites where cleanup will be paid for by potentially v- responsible parties.Available information varies by state. Date of Government Version:N/A Source: Department of Environmental Quality Date Data Arrived at EDR:N/A Telephone: 804-698-4236 Date Made Active in Reports:N/A Last EDR Contact:12/19/2014 Number of Days to Update:N/A Next Scheduled EDR Contact:04/06/2015 tar Data Release Frequency:N/A vrr err INF err vrr TC4182090.2s Page GR-4 vow *sr GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING State and tribal landfill and/or solid waste disposal site lists err SWF/LF: Solid Waste Management Facilities `Mr Solid Waste Facilities/Landfill Sites.SWF/LF type records typically contain an inventory of solid waste disposal facilities or landfills in a particular state.Depending on the state,these may be active or inactive facilities or open dumps that failed to meet RCRA Subtitle D Section 4004 criteria for solid waste landfills or disposal or sites. Date of Government Version:09/18/2014 Source: Department of Environmental Quality mow Date Data Arrived at EDR:09/19/2014 Telephone: 804-698-4238 Date Made Active in Reports:11/11/2014 Last EDR Contact:12/08/2014 low Number of Days to Update:53 Next Scheduled EDR Contact:03/23/2015 Data Release Frequency:Quarterly w State and tribal leaking storage tank lists Aar LUST REG SC: Leaking Underground Storage Tanks Leaking underground storage tank site locations. Includes:counties of Amherst,Appomattox,Buckingham,Campbell, Charlotte,Cumberland, Halifax,Lunenburg,Mecklenburg, Nottoway,Pittsylvania, Prince Deward;cities of Danville, Lynchburg. wrr Date of Government Version:09/06/2013 Source: Department of Environmental Quality,South Central Region low Date Data Arrived at EDR:09/06/2013 Telephone: 434-582-5120 Date Made Active in Reports:09/17/2013 Last EDR Contact:11/25/2014 vow Number of Days to Update:11 Next Scheduled EDR Contact:03/16/2015 Data Release Frequency:Semi-Annually vow LUST REG NO: Leaking Underground Storage Tank Tracking Database Air Leaking underground storage tank site locations. Includes:counties of Arlington,Caroline,Culpeper,Fairfax, Fauquier,King George,Loudoun, Louisa,Madison,Orange,Prince William, Rappahannock,Spotsylvania,Stafford; 'a"' cities of Alexandria, Fairfax, Falls Church,Fredericksburg,Manassas,Manassas Park. Date of Government Version:05/18/2004 Source: Department of Environmental Quality Northern Regional Office Date Data Arrived at EDR:05/22/2004 Telephone: 703-583-3800 wrr Date Made Active in Reports:07/09/2004 Last EDR Contact:09/06/2011 Number of Days to Update:48 Next Scheduled EDR Contact:12/19/2011 *or Data Release Frequency:No Update Planned misiv LUST REG VA: Leaking Underground Storage Tank List Leaking underground storage tank site locations. Includes:counties of Albemarle,Augusta,Bath,Clarke,Fluvanna, `o" Frederick,Greene,Highland, Nelson, Page, Rockbridge,Rockingham,Shenandoah,Warren;cities of Buena Vista, Air Charlottesville,Harrisonburg,Lexington,Staunton,Waynesboro,Winchester. Date of Government Version:12/06/2011 Source: Department of Environmental Quality Valley Regional Office `"r Date Data Arrived at EDR:12/08/2011 Telephone: 540-574-7800 Date Made Active in Reports:01/16/2012 Last EDR Contact:11/25/2014 Number of Days to Update:39 Next Scheduled EDR Contact:03/16/2015 wrrr Data Release Frequency:No Update Planned LUST REG WC: Leaking Underground Storage Tank List Leaking underground storage tank site locations. Includes:counties of Alleghany,Bedford,Botetourt,Craig, Floyd, Franklin,Giles, Henry, Montgomery, Patrick,Pulaski, Roanoke;cities of Bedford,Clifton Forge,Covington, Martinsville, Radford, Roanoke,Salem. irr • Date of Government Version:09/09/2013 Source: Department of Environmental Quality West Central Regional Office Date Data Arrived at EDR:09/11/2013 Telephone: 540-562-6700 Ayr Date Made Active in Reports:11/11/2013 Last EDR Contact: 11/25/2014 — Number of Days to Update:61 Next Scheduled EDR Contact:03/16/2015 Data Release Frequency:No Update Planned Now Visrr +rr it +r TC4182090.2s Page GR-5 Aar Now rr GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING LUST REG PD: Leaking Underground Storage Tank Sites Nio` Leaking underground storage tank site locaitons. Includes:counties of Amelia, Brunswick,Charles City,Chesterfield, Now Dinwiddie, Essex,Gloucester,Goochland,Greensville,Hanover,Henrico,King and Queen,King William,Lancaster, Mathews, Middlesex,New Kent, Northumberland,Powhatan, Prince George, Richmond,Surry,Sussex,Westmoreland; .ow cities of Colonial Heights,Emporia, Hopewell, Petersburg. Date of Government Version:09/03/2014 Source: Department of Environmental Quality Piedmont Regional Office Now Date Data Arrived at EDR:09/04/2014 Telephone: 804-527-5020 Date Made Active in Reports:11/11/2014 Last EDR Contact:12/01/2014 wrr Number of Days to Update:68 Next Scheduled EDR Contact:03/16/2015 �r Data Release Frequency:Quarterly - LUST REG TD: Leaking Underground Storage Tank Sites Leaking underground storage tank site locations. Includes:counties of Accomack, Isle of Wight,James City,Northampton, vow Southampton,York;cities of Chesapeake, Franklin,Hampton,Newport News, Norfolk, Poquoson, Portsmouth,Suffolk, Virginia Beach,Williamsburg. err Date of Government Version:06/30/2013 Source: Department of Environmental Quality Tidewater Regional Office Date Data Arrived at EDR:07/05/2013 Telephone: trofoia @deq.vir Date Made Active in Reports:09/16/2013 Last EDR Contact: 12/23/2014 �r Number of Days to Update:73 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Quarterly low LUST REG SW: Leaking Underground Storage Tank Database Now Leaking underground storage tank site locations. Includes:counties of Bland, Buchanan,Carroll,Dickenson,Grayson, Lee, Russell,Scott,Smyth,Tazewell,Washington,Wise,Wythe;cities of Bristol,Galax,Norton. wr Date of Government Version:07/15/2013 Source: Department of Environmental Quality Southwest Regional Office Date Data Arrived at EDR:07/18/2013 Telephone: 276-676-4800 Date Made Active in Reports:09/16/2013 Last EDR Contact:01/12/2015 rrr Number of Days to Update:60 Next Scheduled EDR Contact:04/27/2015 Data Release Frequency:No Update Planned Now LTANKS: Leaking Petroleum Storage Tanks Includes releases of petroleum from underground storage tanks and aboveground storage tanks. "— Date of Government Version:08/04/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:09/04/2014 Telephone: 804-698-4010 — Date Made Active in Reports:11/11/2014 Last EDR Contact:12/03/2014 Number of Days to Update:68 Next Scheduled EDR Contact:03/16/2015 ,wor Data Release Frequency:Quarterly 'o' INDIAN LUST R9: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Arizona,California,New Mexico and Nevada Vie Date of Government Version:03/01/2013 Source: Environmental Protection Agency 'r'° Date Data Arrived at EDR:03/01/2013 Telephone: 415-972-3372 Date Made Active in Reports:04/12/2013 Last EDR Contact:12/09/2014 Now Number of Days to Update:42 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Quarterly Auer INDIAN LUST R5: Leaking Underground Storage Tanks on Indian Land ANY Leaking underground storage tanks located on Indian Land in Michigan,Minnesota and Wisconsin. 'r' Date of Government Version:11/03/2014 Source: EPA, Region 5 Date Data Arrived at EDR:11/05/2014 Telephone: 312-886-7439 Now Date Made Active in Reports:11/17/2014 Last EDR Contact:10/27/2014 Number of Days to Update:12 Next Scheduled EDR Contact:02/09/2015 Now Data Release Frequency:Varies yr +rrr Aar +rr l r TC4182090.2s Page GR-6 IOW vrr vr. NNW GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING NOW INDIAN LUST R8: Leaking Underground Storage Tanks on Indian Land IOW LUSTs on Indian land in Colorado,Montana,North Dakota,South Dakota, Utah and Wyoming. Now Date of Government Version: 11/04/2014 Source: EPA Region 8 Date Data Arrived at EDR:11/07/2014 Telephone: 303-312-6271 for Date Made Active in Reports:11/17/2014 Last EDR Contact:10/27/2014 Number of Days to Update:10 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Quarterly `ow INDIAN LUST R7: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Iowa,Kansas,and Nebraska New Date of Government Version:05/22/2014 Source: EPA Region 7 vrr Date Data Arrived at EDR:08/22/2014 Telephone: 913-551-7003 Date Made Active in Reports:09/18/2014 Last EDR Contact: 10/27/2014 AO' Number of Days to Update:27 Next Scheduled EDR Contact:02/09/2015 rr° Data Release Frequency:Varies INDIAN LUST R6: Leaking Underground Storage Tanks on Indian Land *41W LUSTs on Indian land in New Mexico and Oklahoma. 'w Date of Government Version: 10/06/2014 Source: EPA Region 6 Date Data Arrived at EDR:10/29/2014 Telephone: 214-665-6597 — Date Made Active in Reports:11/17/2014 Last EDR Contact: 10/27/2014 Number of Days to Update:19 Next Scheduled EDR Contact:02/09/2015 Now Data Release Frequency:Varies err INDIAN LUST R4: Leaking Underground Storage Tanks on Indian Land moo LUSTs on Indian land in Florida,Mississippi and North Carolina. Date of Government Version:07/30/2014 Source: EPA Region 4 Now Date Data Arrived at EDR:08/12/2014 Telephone: 404-562-8677 Date Made Active in Reports:08/22/2014 Last EDR Contact:10/27/2014 Now Number of Days to Update:10 Next Scheduled EDR Contact:02/09/2015 Now Data Release Frequency:Semi-Annually Now INDIAN LUST R1: Leaking Underground Storage Tanks on Indian Land A listing of leaking underground storage tank locations on Indian Land. — Date of Government Version:02/01/2013 Source: EPA Region 1 Date Data Arrived at EDR:05/01/2013 Telephone: 617-918-1313 Date Made Active in Reports:11/01/2013 Last EDR Contact:10/31/2014 Nor Number of Days to Update:184 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Varies vow INDIAN LUST R10: Leaking Underground Storage Tanks on Indian Land — LUSTs on Indian land in Alaska, Idaho,Oregon and Washington. Date of Government Version:05/20/2014 Source: EPA Region 10 err Date Data Arrived at EDR:06/10/2014 Telephone: 206-553-2857 Date Made Active in Reports:08/22/2014 Last EDR Contact:10/27/2014 Number of Days to Update:73 Next Scheduled EDR Contact:02/09/2015 Now Data Release Frequency:Quarterly — State and tribal registered storage tank lists law UST: Registered Petroleum Storage Tanks Registered Underground Storage Tanks. UST's are regulated under Subtitle I of the Resource Conservation and Recovery "r'` Act(RCRA)and must be registered with the state department responsible for administering the UST program.Available information varies by state program. vrr .r vw Air .ww Vow' TC4182090.2s Page GR-7 Now Nw ti.. it yr - GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Date of Government Version:08/04/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:09/04/2014 Telephone: 804-698-4010 Date Made Active in Reports:11/10/2014 Last EDR Contact: 12/03/2014 Number of Days to Update:67 Next Scheduled EDR Contact:03/16/2015 .410e Data Release Frequency:Semi-Annually "air AST: Registered Petroleum Storage Tanks Registered Aboveground Storage Tanks. mow Date of Government Version:08/04/2014 Source: Department of Environmental Quality IOW Date Data Arrived at EDR:09/04/2014 Telephone: 804-698-4010 Date Made Active in Reports:11/10/2014 Last EDR Contact: 12/03/2014 ,o. Number of Days to Update:67 Next Scheduled EDR Contact:03/16/2015 Data Release Frequency:Semi-Annually ar` INDIAN UST R4: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian land in EPA Region 4(Alabama,Florida,Georgia, Kentucky, Mississippi,North Carolina,South Carolina,Tennessee Are and Tribal Nations) .r Date of Government Version:07/30/2014 Source: EPA Region 4 Date Data Arrived at EDR:08/12/2014 Telephone: 404-562-9424 Aar Date Made Active in Reports:08/22/2014 Last EDR Contact: 10/27/2014 Number of Days to Update:10 Next Scheduled EDR Contact:02/09/2015 `r Data Release Frequency:Semi-Annually Nor, INDIAN UST R8: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian INF land in EPA Region 8(Colorado,Montana, North Dakota,South Dakota,Utah,Wyoming and 27 Tribal Nations). '411P• Date of Government Version:11/04/2014 Source: EPA Region 8 Date Data Arrived at EDR:11/07/2014 Telephone: 303-312-6137 "ny Date Made Active in Reports:11/17/2014 Last EDR Contact:10/27/2014 Number of Days to Update:10 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Quarterly INDIAN UST R1: Underground Storage Tanks on Indian Land Air The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian land in EPA Region 1 (Connecticut,Maine,Massachusetts,New Hampshire,Rhode Island,Vermont and ten Tribal iv Nations). Date of Government Version:02/01/2013 Source: EPA,Region 1 Date Data Arrived at EDR:05/01/2013 Telephone: 617-918-1313 ter► Date Made Active in Reports:01/27/2014 Last EDR Contact: 10/31/2014 Number of Days to Update:271 Next Scheduled EDR Contact:02/09/2015 +ir Data Release Frequency:Varies ANY INDIAN UST R9: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian wr land in EPA Region 9(Arizona,California,Hawaii,Nevada,the Pacific Islands,and Tribal Nations). ew Date of Government Version:08/14/2014 Source: EPA Region 9 Date Data Arrived at EDR:08/15/2014 Telephone: 415-972-3368 vow Date Made Active in Reports:08/22/2014 Last EDR Contact:10/27/2014 Number of Days to Update:7 Next Scheduled EDR Contact:02/09/2015 err Data Release Frequency:Quarterly Air INDIAN UST R5: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian — land in EPA Region 5(Michigan,Minnesota and Wisconsin and Tribal Nations). err '4111r IOW TC4182090.2s Page GR-8 .r - GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING vir Date of Government Version:11/03/2014 Source: EPA Region 5 Date Data Arrived at EDR:11/05/2014 Telephone: 312-886-6136 ir Date Made Active in Reports:11/17/2014 Last EDR Contact:10/27/2014 Number of Days to Update:12 Next Scheduled EDR Contact:02/09/2015 +err° Data Release Frequency:Varies +rr INDIAN UST R10: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian fele land in EPA Region 10(Alaska, Idaho,Oregon,Washington,and Tribal Nations). vrr Date of Government Version:05/20/2014 Source: EPA Region 10 Date Data Arrived at EDR:06/10/2014 Telephone: 206-553-2857 taw Date Made Active in Reports:08/15/2014 Last EDR Contact: 10/27/2014 Number of Days to Update:66 Next Scheduled EDR Contact:02/09/2015 law Data Release Frequency:Quarterly w INDIAN UST R6: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian i land in EPA Region 6(Louisiana,Arkansas,Oklahoma,New Mexico,Texas and 65 Tribes). low Date of Government Version: 10/06/2014 Source: EPA Region 6 Date Data Arrived at EDR:10/29/2014 Telephone: 214-665-7591 'o` Date Made Active in Reports:11/06/2014 Last EDR Contact:10/27/2014 Number of Days to Update:8 Next Scheduled EDR Contact:02/09/2015 `O" Data Release Frequency:Semi-Annually INDIAN UST R7: Underground Storage Tanks on Indian Land mow The Indian Underground Storage Tank(UST)database provides information about underground storage tanks on Indian land in EPA Region 7(Iowa,Kansas,Missouri, Nebraska,and 9 Tribal Nations). 410'" Date of Government Version:08/20/2014 Source: EPA Region 7 Date Data Arrived at EDR:08/22/2014 Telephone: 913-551-7003 "" Date Made Active in Reports:09/18/2014 Last EDR Contact:10/27/2014 Number of Days to Update:27 Next Scheduled EDR Contact:02/09/2015 tir+► Data Release Frequency:Varies virr FEMA UST: Underground Storage Tank Listing ,r„ A listing of all FEMA owned underground storage tanks. Date of Government Version:01/01/2010 Source: FEMA " Date Data Arrived at EDR:02/16/2010 Telephone: 202-646-5797 Date Made Active in Reports:04/12/2010 Last EDR Contact:01/12/2015 vow Number of Days to Update:55 Next Scheduled EDR Contact:04/27/2015 v,, Data Release Frequency:Varies ,r, State and tribal institutional control/engineering control registries �r ENG CONTROLS: Engineering Controls Sites Listing A listing of sites with Engineering Controls in place.Engineering controls include various forms of caps,building — foundations,liners,and treatment methods to create pathway elimination for regulated substances to enter environmental media or effect human health. v1yr Date of Government Version:09/29/2014 Source: Department of Environmental Quality 'ftr+ Date Data Arrived at EDR:09/30/2014 Telephone: 804-698-4228 Date Made Active in Reports:11/10/2014 Last EDR Contact:09/29/2015 mow Number of Days to Update:41 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Quarterly Aar INST CONTROL: Voluntary Remediation Program Database *ow Sites included in the Voluntary Remediation Program database that have deed restrictions. vrr IOW NNW yr TC4182090.2s Page GR-9 ler Now Now r law GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Date of Government Version:09/29/2014 Source: Department of Environmental Quality vr Date Data Arrived at EDR:09/30/2014 Telephone: 804-698-4228 Date Made Active in Reports:11/10/2014 Last EDR Contact:09/29/2015 Number of Days to Update:41 Next Scheduled EDR Contact:04/13/2015 +�rw Data Release Frequency:Quarterly IOW State and tribal voluntary cleanup sites "+r" INDIAN VCP R7: Voluntary Cleanup Priority Lisitng A listing of voluntary cleanup priority sites located on Indian Land located in Region 7. Nor Date of Government Version:03/20/2008 Source: EPA, Region 7 Alr Date Data Arrived at EDR:04/22/2008 Telephone: 913-551-7365 Date Made Active in Reports:05/19/2008 Last EDR Contact:04/20/2009 yr Number of Days to Update:27 Next Scheduled EDR Contact:07/20/2009 Data Release Frequency:Varies INDIAN VCP R1: Voluntary Cleanup Priority Listing A listing of voluntary cleanup priority sites located on Indian Land located in Region 1. vow Date of Government Version:09/29/2014 Source: EPA, Region 1 Date Data Arrived at EDR:10/01/2014 Telephone: 617-918-1102 - Date Made Active in Reports:11/06/2014 Last EDR Contact:12/31/2014 Number of Days to Update:36 Next Scheduled EDR Contact:04/13/2015 - Data Release Frequency:Varies *OW VRP: Voluntary Remediation Program The Voluntary Cleanup Program encourages owners of elected contaminated sites to take the initiative and conduct �r voluntary cleanups that meet state environmental standards. — Date of Government Version:09/29/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:09/30/2014 Telephone: 804-698-4228 "r"' Date Made Active in Reports:11/10/2014 Last EDR Contact:09/29/2015 Number of Days to Update:41 Next Scheduled EDR Contact:04/13/2015 +,rr Data Release Frequency:Quarterly ter+ State and tribal Brownfields sites vaire BROWNFIELDS: Brownfields Site Specific Assessments Aar To qualify for Brownfields Assessment,the site must meet the Federal definition of a Brownfields and should have contaminant issues that need to be addressed and a redevelopment plan supported by the local government and community. New Virginia's Department of Environmental Quality performs brownfields assessments under a cooperative agreement with the U.S. Environmental Protection Agency at no cost to communities,property owners or,prospective purchasers. Iew The assessment is an evaluation of environmental impacts caused by previous site uses similar to a Phase II Environmental Assessment. vie Date of Government Version:01/29/2014 Source: Department of Environmental Quality A r Date Data Arrived at EDR:01/30/2014 Telephone: 804-698-4207 Date Made Active in Reports:03/04/2014 Last EDR Contact:10/27/2014 low Number of Days to Update:33 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Varies New ADDITIONAL ENVIRONMENTAL RECORDS wrr Local Brownfield lists trr US BROWNFIELDS: A Listing of Brownfields Sites Brownfields are real property,the expansion,redevelopment,or reuse of which may be complicated by the presence or potential presence of a hazardous substance,pollutant,or contaminant.Cleaning up and reinvesting in these rrw properties takes development pressures off of undeveloped,open land,and both improves and protects the environment. Assessment,Cleanup and Redevelopment Exchange System(ACRES)stores information reported by EPA Brownfields low grant recipients on brownfields properties assessed or cleaned up with grant funding as well as information on Targeted Brownfields Assessments performed by EPA Regions.A listing of ACRES Brownfield sites is obtained from As. Cleanups in My Community.Cleanups in My Community provides information on Brownfields properties for which information is reported back to EPA,as well as areas served by Brownfields grant programs. vow wrr TC4182090.2s Page GR-10 +rr W wr wr GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING err - vWr Date of Government Version:09/22/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:09/23/2014 Telephone: 202-566-2777 Date Made Active in Reports:10/20/2014 Last EDR Contact: 12/22/2014 Number of Days to Update:27 Next Scheduled EDR Contact:04/06/2015 rwr Data Release Frequency:Semi-Annually rrr Local Lists of Landfill/Solid Waste Disposal Sites v r DEBRIS REGION 9: Torres Martinez Reservation Illegal Dump Site Locations A listing of illegal dump sites location on the Torres Martinez Indian Reservation located in eastern Riverside `ow County and northern Imperial County,California. low Date of Government Version:01/12/2009 Source: EPA, Region 9 Date Data Arrived at EDR:05/07/2009 Telephone: 415-947-4219 wr Date Made Active in Reports:09/21/2009 Last EDR Contact: 10/24/2014 Number of Days to Update:137 Next Scheduled EDR Contact:02/09/2015 — Data Release Frequency:No Update Planned ODI: Open Dump Inventory An open dump is defined as a disposal facility that does not comply with one or more of the Part 257 or Part 258 Subtitle D Criteria. ,4110, Date of Government Version:06/30/1985 Source: Environmental Protection Agency Date Data Arrived at EDR:08/09/2004 Telephone: 800-424-9346 V" Date Made Active in Reports:09/17/2004 Last EDR Contact:06/09/2004 Number of Days to Update:39 Next Scheduled EDR Contact:N/A AVir Data Release Frequency:No Update Planned INDIAN ODI: Report on the Status of Open Dumps on Indian Lands mar Location of open dumps on Indian land. Date of Government Version: 12/31/1998 Source: Environmental Protection Agency Mar Date Data Arrived at EDR:12/03/2007 Telephone: 703-308-8245 Date Made Active in Reports:01/24/2008 Last EDR Contact:10/29/2014 Number of Days to Update:52 Next Scheduled EDR Contact:02/16/2015 Ar Data Release Frequency:Varies Local Lists of Hazardous waste/Contaminated Sites woo US CDL: Clandestine Drug Labs A listing of clandestine drug lab locations.The U.S.Department of Justice("the Department")provides this err web site as a public service. It contains addresses of some locations where law enforcement agencies reported they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites. — In most cases,the source of the entries is not the Department,and the Department has not verified the entry and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by,for example, contacting local law enforcement and local health departments. Are Date of Government Version:07/25/2014 Source: Drug Enforcement Administration Date Data Arrived at EDR:09/09/2014 Telephone: 202-307-1000 AMY Date Made Active in Reports:10/20/2014 Last EDR Contact:11/25/2014 Number of Days to Update:41 Next Scheduled EDR Contact:03/16/2015 Nov Data Release Frequency:Quarterly MOW US HIST CDL: National Clandestine Laboratory Register A listing of clandestine drug lab locations.The U.S. Department of Justice("the Department")provides this — web site as a public service. It contains addresses of some locations where law enforcement agencies reported Ammo they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites. In most cases,the source of the entries is not the Department,and the Department has not verified the entry ,r and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by,for example, contacting local law enforcement and local health departments. err w Nor w +rr TC4182090.2s Page GR-11 wr `+rr vrr GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING NIW - AMY Date of Government Version:07/25/2014 Source: Drug Enforcement Administration Aar Date Data Arrived at EDR:09/09/2014 Telephone: 202-307-1000 Date Made Active in Reports:10/20/2014 Last EDR Contact:11/25/2014 vow Number of Days to Update:41 Next Scheduled EDR Contact:03/16/2015 irr Data Release Frequency:No Update Planned err Local Land Records wr LIENS 2: CERCLA Lien Information A Federal CERCLA('Superfund')lien can exist by operation of law at any site or property at which EPA has spent — Superfund monies.These monies are spent to investigate and address releases and threatened releases of contamination. CERCLIS provides information as to the identity of these sites and properties. Ave Date of Government Version:02/18/2014 Source: Environmental Protection Agency low— Date Data Arrived at EDR:03/18/2014 Telephone: 202-564-6023 Date Made Active in Reports:04/24/2014 Last EDR Contact:10/27/2014 '°r Number of Days to Update:37 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Varies law Records of Emergency Release Reports HMIRS: Hazardous Materials Information Reporting System Srr Hazardous Materials Incident Report System. HMIRS contains hazardous material spill incidents reported to DOT. vow Date of Government Version:09/30/2014 Source: U.S.Department of Transportation Date Data Arrived at EDR:10/01/2014 Telephone: 202-366-4555 var Date Made Active in Reports:11/06/2014 Last EDR Contact:12/30/2014 Number of Days to Update:36 Next Scheduled EDR Contact:04/13/2015 ww� Data Release Frequency:Annually y+r SPILLS PC: Pollution Complaint Database Pollution Complaints Database.The pollution reports contained in the PC database include the initial release reporting of Leaking Underground Storage Tanks and all other releases of petroleum to the environment as well Air as releases to state waters.The database is current through 12/1/93.Since that time,all spill and pollution reporting information has been collected and tracked through the DEQ regional offices. vow Date of Government Version:06/01/1996 Source: Department of Environmental Quality low Date Data Arrived at EDR:10/22/1996 Telephone: 804-698-4287 Date Made Active in Reports:11/21/1996 Last EDR Contact:03/08/2010 Number of Days to Update:30 Next Scheduled EDR Contact:06/21/2010 Data Release Frequency:No Update Planned 11111 SPILLS NO: PREP Database +are The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to air,water,and waste pollution incidents in order to protect human health and the environment. ler Date of Government Version:09/23/2009 Source: Department of Environmental Quality, Northern Region tiro- Date Data Arrived at EDR:09/29/2009 Telephone: 703-583-3864 Date Made Active in Reports:10/30/2009 Last EDR Contact:09/06/2011 rrr Number of Days to Update:31 Next Scheduled EDR Contact: 12/19/2011 Data Release Frequency:No Update Planned Aar SPILLS PD: PREP Database The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to air,water,and waste pollution incidents in order to protect human health and the environment. Aar Date of Government Version: 10/20/2009 Source: Department of Environmental Quality, Piedmont Region +m Date Data Arrived at EDR:10/29/2009 Telephone: 804-527-5020 Date Made Active in Reports:12/03/2009 Last EDR Contact:02/06/2012 Nor Number of Days to Update:35 Next Scheduled EDR Contact:05/21/2012 *sr Data Release Frequency:Quarterly vrr rrr TC4182090.2s Page GR-12 IOW GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING .r SPILLS SW: Reportable Spills The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to ,r air,water,and waste pollution incidents in order to protect human health and the environment. Date of Government Version:01/21/2010 Source: Department of Environmental Quality,Southwest Region Date Data Arrived at EDR:01/22/2010 Telephone: 276-676-4839 Date Made Active in Reports:02/16/2010 Last EDR Contact:07/13/2012 err Number of Days to Update:25 Next Scheduled EDR Contact:10/29/2012 Data Release Frequency:No Update Planned SPILLS TD: PREP Database The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to Aar air,water,and waste pollution incidents in order to protect human health and the environment. Date of Government Version:09/17/2009 Source: Department of Environmental Quality,Tidewater Region err Date Data Arrived at EDR:09/23/2009 Telephone: trofoia @deq.vir Date Made Active in Reports:10/06/2009 Last EDR Contact:09/06/2011 Are Number of Days to Update: 13 Next Scheduled EDR Contact:12/19/2011 low Data Release Frequency:Quarterly — SPILLS VA: PREP Database The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to — air,water,and waste pollution incidents in order to protect human health and the environment. viv Date of Government Version:08/08/2012 Source: Department of Environmental Quality,Valley Regional Office Date Data Arrived at EDR:08/09/2012 Telephone: 540-574-7800 vow— Date Made Active in Reports:10/05/2012 Last EDR Contact:05/06/2013 Number of Days to Update:57 Next Scheduled EDR Contact:08/19/2013 �+► Data Release Frequency:Quarterly kr+ SPILLS: Prep/Spills Database Listing The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to `— air,water,and waste pollution incidents in order to protect human health and the environment.PREP staff often work to assist local emergency responders,other state agencies,federal agencies,and responsible parties,as may be needed,to manage pollution incidents.Oil spills,fish kills,and hazardous materials spills are examples yr of incidents that may involve the DEQ's PREP Program. Date of Government Version:08/04/2014 Source: Department of Environmental Quality iNow Date Data Arrived at EDR:09/04/2014 Telephone: 804-698-4287 Date Made Active in Reports:11/11/2014 Last EDR Contact:12/04/2014 "'r Number of Days to Update:68 Next Scheduled EDR Contact:03/16/2015 111W Data Release Frequency:Varies SPILLS WC: Prep Database The Department of Environmental Quality's POLLUTION RESPONSE PROGRAM,known as PREP,provides for responses to air,water,and waste pollution incidents in order to protect human health and the environment. Date of Government Version:09/21/2009 Source: Department of Environmental Quality,West Central Region vow Date Data Arrived at EDR:09/29/2009 Telephone: 540-562-6700 Date Made Active in Reports:10/30/2009 Last EDR Contact:09/06/2011 ago, Number of Days to Update:31 Next Scheduled EDR Contact:12/19/2011 ®,, Data Release Frequency:No Update Planned ,r, SPILLS BRL: Prep/Spills Database Listing A listing of spills locations located in the Blue Ridge Regional area, Lynchburg. Date of Government Version:09/18/2009 Source: DEQ,Blue Ridge Regional Office Date Data Arrived at EDR:09/18/2009 Telephone: 434-582-6218 Date Made Active in Reports:10/06/2009 Last EDR Contact: 11/28/2011 �, Number of Days to Update:18 Next Scheduled EDR Contact:03/12/2012 Data Release Frequency:Varies ar IOW 41100 NNW wr +rr TC4182090.2s Page GR-13 111r ®rr. GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING SPILLS 90: SPILLS90 data from FirstSearch Spills 90 includes those spill and release records available exclusively from FirstSearch databases.Typically, they may include chemical,oil and/or hazardous substance spills recorded after 1990. Duplicate records that are viv already included in EDR incident and release records are not included in Spills 90. "i++' Date of Government Version:09/01/2012 Source: FirstSearch Date Data Arrived at EDR:01/03/2013 Telephone: N/A Date Made Active in Reports:02/15/2013 Last EDR Contact:01/03/2013 Number of Days to Update:43 Next Scheduled EDR Contact:N/A vow Data Release Frequency:No Update Planned moor Other Ascertainable Records wr. RCRA NonGen/NLR: RCRA-Non Generators irr RCRAInfo is EPA's comprehensive information system,providing access to data supporting the Resource Conservation and Recovery Act(RCRA)of 1976 and the Hazardous and Solid Waste Amendments(HSWA)of 1984.The database .wr includes selective information on sites which generate,transport,store,treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act(RCRA).Non-Generators do not presently generate hazardous waste. err Date of Government Version:06/10/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:07/02/2014 Telephone: 800-438-2474 law Date Made Active in Reports:09/18/2014 Last EDR Contact:12/29/2014 Number of Days to Update:78 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Varies DOT OPS: Incident and Accident Data Department of Transporation,Office of Pipeline Safety Incident and Accident data. .rr Date of Government Version:07/31/2012 Source: Department of Transporation,Office of Pipeline Safety <rr Date Data Arrived at EDR:08/07/2012 Telephone: 202-366-4595 Date Made Active in Reports:09/18/2012 Last EDR Contact: 11/04/2014 �► Number of Days to Update:42 Next Scheduled EDR Contact:02/16/2015 Data Release Frequency:Varies yr DOD: Department of Defense Sites '- This data set consists of federally owned or administered lands,administered by the Department of Defense,that have any area equal to or greater than 640 acres of the United States, Puerto Rico,and the U.S.Virgin Islands. vow Date of Government Version: 12/31/2005 Source: USGS Date Data Arrived at EDR:11/10/2006 Telephone: 888-275-8747 Date Made Active in Reports:01/11/2007 Last EDR Contact: 11/07/2014 vs, Number of Days to Update:62 Next Scheduled EDR Contact:01/26/2015 .ir Data Release Frequency:Semi-Annually FUDS: Formerly Used Defense Sites �r► The listing includes locations of Formerly Used Defense Sites properties where the US Army Corps of Engineers ,r, is actively working or will take necessary cleanup actions. Date of Government Version:06/06/2014 Source: U.S.Army Corps of Engineers ""° Date Data Arrived at EDR:09/10/2014 Telephone: 202-528-4285 Date Made Active in Reports:09/18/2014 Last EDR Contact: 12/12/2014 `r` Number of Days to Update:8 Next Scheduled EDR Contact:03/23/2015 Data Release Frequency:Varies Amy „a, CONSENT: Superfund(CERCLA)Consent Decrees Major legal settlements that establish responsibility and standards for cleanup at NPL(Superfund)sites.Released "Yrr periodically by United States District Courts after settlement by parties to litigation matters. 4111, Nov tar w1, err. yr TC4182090.2s Page GR-14 GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Date of Government Version: 12/31/2013 Source: Department of Justice,Consent Decree Library '"r" Date Data Arrived at EDR:01/24/2014 Telephone: Varies Date Made Active in Reports:02/24/2014 Last EDR Contact:12/24/2014 Number of Days to Update:31 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Varies Air Records Of Decision Record of Decision.ROD documents mandate a permanent remedy at an NPL(Superfund)site containing technical Air and health information to aid in the cleanup. Date of Government Version: 11/25/2013 Source: EPA Date Data Arrived at EDR:12/12/2013 Telephone: 703-416-0223 Date Made Active in Reports:02/24/2014 Last EDR Contact:12/12/2014 Number of Days to Update:74 Next Scheduled EDR Contact:03/23/2015 err Data Release Frequency:Annually AMP" UMTRA: Uranium Mill Tailings Sites Uranium ore was mined by private companies for federal government use in national defense programs.When the mills Air shut down,large piles of the sand-like material(mill tailings)remain after uranium has been extracted from the ore. Levels of human exposure to radioactive materials from the piles are low;however,in some cases tailings were used as construction materials before the potential health hazards of the tailings were recognized. 41.0, Date of Government Version:09/14/2010 Source: Department of Energy Date Data Arrived at EDR:10/07/2011 Telephone: 505-845-0011 Date Made Active in Reports:03/01/2012 Last EDR Contact: 11/26/2014 Number of Days to Update:146 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Varies US MINES: Mines Master Index File Contains all mine identification numbers issued for mines active or opened since 1971.The data also includes violation information. yr Date of Government Version:08/05/2014 Source: Department of Labor, Mine Safety and Health Administration Date Data Arrived at EDR:09/04/2014 Telephone: 303-231-5959 "r'' Date Made Active in Reports:11/17/2014 Last EDR Contact:12/30/2014 Number of Days to Update:74 Next Scheduled EDR Contact:03/16/2015 411" Data Release Frequency:Semi-Annually TRIS: Toxic Chemical Release Inventory System Toxic Release Inventory System.TRIS identifies facilities which release toxic chemicals to the air,water and land in reportable quantities under SARA Title III Section 313. w" Date of Government Version:12/31/2011 Source: EPA Date Data Arrived at EDR:07/31/2013 Telephone: 202-566-0250 Asp Date Made Active in Reports:09/13/2013 Last EDR Contact:11/26/2014 Air Number of Days to Update:44 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Annually �r TSCA: Toxic Substances Control Act Toxic Substances Control Act.TSCA identifies manufacturers and importers of chemical substances included on the TSCA Chemical Substance Inventory list. It includes data on the production volume of these substances by plant site. Date of Government Version:12/31/2006 Source: EPA rrr Date Data Arrived at EDR:09/29/2010 Telephone: 202-260-5521 Date Made Active in Reports:12/02/2010 Last EDR Contact: 12/22/2014 Number of Days to Update:64 Next Scheduled EDR Contact:04/06/2015 - Data Release Frequency:Every 4 Years law wrr, AMP' wt11r Air TC4182090.2s Page GR-15 NM/ IOW Air Air Mir GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Air FTTS: FIFRA/TSCA Tracking System-FIFRA(Federal Insecticide, Fungicide,&Rodenticide Act)/TSCA(Toxic Substances Control Act) er FTTS tracks administrative cases and pesticide enforcement actions and compliance activities related to FIFRA, TSCA and EPCRA(Emergency Planning and Community Right-to-Know Act).To maintain currency,EDR contacts the `®"° Agency on a quarterly basis. w,r Date of Government Version:04/09/2009 Source: EPA/Office of Prevention,Pesticides and Toxic Substances Date Data Arrived at EDR:04/16/2009 Telephone: 202-566-1667 — Date Made Active in Reports:05/11/2009 Last EDR Contact:11/19/2014 Number of Days to Update:25 Next Scheduled EDR Contact:03/09/2015 °"w Data Release Frequency:Quarterly FTTS INSP: FIFRA/TSCA Tracking System-FIFRA(Federal Insecticide,Fungicide,&Rodenticide Act)/TSCA(Toxic Substances Control Act) 411W A listing of FIFRA/TSCA Tracking System(FTTS)inspections and enforcements. Date of Government Version:04/09/2009 Source: EPA �✓ Date Data Arrived at EDR:04/16/2009 Telephone: 202-566-1667 Date Made Active in Reports:05/11/2009 Last EDR Contact:11/19/2014 Number of Days to Update:25 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Quarterly HIST FTTS: FIFRA/TSCA Tracking System Administrative Case Listing IOW A complete administrative case listing from the FIFRA/TSCA Tracking System(FTTS)for all ten EPA regions.The information was obtained from the National Compliance Database(NCDB).NCDB supports the implementation of FIFRA vir (Federal Insecticide,Fungicide,and Rodenticide Act)and TSCA(Toxic Substances Control Act).Some EPA regions Aar, are now closing out records.Because of that,and the fact that some EPA regions are not providing EPA Headquarters with updated records,it was decided to create a HIST FTTS database. It included records that may not be included 'OW in the newer FTTS database updates.This database is no longer updated. tar Date of Government Version: 10/19/2006 Source: Environmental Protection Agency Date Data Arrived at EDR:03/01/2007 Telephone: 202-564-2501 *re Date Made Active in Reports:04/10/2007 Last EDR Contact:12/17/2007 Number of Days to Update:40 Next Scheduled EDR Contact:03/17/2008 err Data Release Frequency:No Update Planned *or HIST FTTS INSP: FIFRA/TSCA Tracking System Inspection&Enforcement Case Listing A complete inspection and enforcement case listing from the FIFRA/TSCA Tracking System(FTTS)for all ten EPA — regions.The information was obtained from the National Compliance Database(NCDB).NCDB supports the implementation of FIFRA(Federal Insecticide,Fungicide,and Rodenticide Act)and TSCA(Toxic Substances Control Act).Some `or EPA regions are now closing out records.Because of that,and the fact that some EPA regions are not providing EPA Headquarters with updated records,it was decided to create a HIST FTTS database.It included records that "'"` may not be included in the newer FTTS database updates.This database is no longer updated. — Date of Government Version:10/19/2006 Source: Environmental Protection Agency Date Data Arrived at EDR:03/01/2007 Telephone: 202-564-2501 'ter Date Made Active in Reports:04/10/2007 Last EDR Contact:12/17/2008 Number of Days to Update:40 Next Scheduled EDR Contact:03/17/2008 err Data Release Frequency:No Update Planned SSTS: Section 7 Tracking Systems Section 7 of the Federal Insecticide,Fungicide and Rodenticide Act,as amended(92 Stat.829)requires all Nor registered pesticide-producing establishments to submit a report to the Environmental Protection Agency by March — 1st each year. Each establishment must report the types and amounts of pesticides,active ingredients and devices being produced,and those having been produced and sold or distributed in the past year. New Date of Government Version: 12/31/2009 Source: EPA err Date Data Arrived at EDR:12/10/2010 Telephone: 202-564-4203 Date Made Active in Reports:02/25/2011 Last EDR Contact:10/27/2014 Number of Days to Update:77 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Annually irr tow ler ewr low TC4182090.2s Page GR-16 AMP 'ir "O' GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING ICIS: Integrated Compliance Information System The Integrated Compliance Information System(ICIS)supports the information needs of the national enforcement and compliance program as well as the unique needs of the National Pollutant Discharge Elimination System(NPDES) program. �r. Date of Government Version:07/31/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:10/29/2014 Telephone: 202-564-5088 ""' Date Made Active in Reports:11/06/2014 Last EDR Contact:01/09/2015 Number of Days to Update:8 Next Scheduled EDR Contact:04/27/2015 Data Release Frequency:Quarterly gar PADS: PCB Activity Database System PCB Activity Database.PADS Identifies generators,transporters,commercial storers and/or brokers and disposers of PCB's who are required to notify the EPA of such activities. `W Date of Government Version:07/01/2014 Source: EPA Date Data Arrived at EDR: 10/15/2014 Telephone: 202-566-0500 err Date Made Active in Reports:11/17/2014 Last EDR Contact: 10/15/2014 Number of Days to Update:33 Next Scheduled EDR Contact:01/26/2015 Data Release Frequency:Annually Qrr MLTS: Material Licensing Tracking System — MLTS is maintained by the Nuclear Regulatory Commission and contains a list of approximately 8,100 sites which possess or use radioactive materials and which are subject to NRC licensing requirements.To maintain currency, ar EDR contacts the Agency on a quarterly basis. Date of Government Version:07/22/2013 Source: Nuclear Regulatory Commission Date Data Arrived at EDR:08/02/2013 Telephone: 301-415-7169 mow Date Made Active in Reports:11/01/2013 Last EDR Contact: 12/04/2014 Number of Days to Update:91 Next Scheduled EDR Contact:03/23/2015 4— Data Release Frequency:Quarterly lop RADINFO: Radiation Information Database The Radiation Information Database(RADINFO)contains information about facilities that are regulated by U.S. Environmental Protection Agency(EPA)regulations for radiation and radioactivity. — Date of Government Version:10/07/2014 Source: Environmental Protection Agency Date Data Arrived at EDR:10/08/2014 Telephone: 202-343-9775 'VW Date Made Active in Reports:10/20/2014 Last EDR Contact:01/08/2015 Number of Days to Update:12 Next Scheduled EDR Contact:04/20/2015 — Data Release Frequency:Quarterly 'VW FINDS: Facility Index System/Facility Registry System Facility Index System.FINDS contains both facility information and'pointers'to other sources that contain more o detail.EDR includes the following FINDS databases in this report:PCS(Permit Compliance System),AIRS(Aerometric Information Retrieval System),DOCKET(Enforcement Docket used to manage and track information on civil judicial enforcement cases for all environmental statutes),FURS(Federal Underground Injection Control),C-DOCKET(Criminal Docket System used to track criminal enforcement actions for all environmental statutes),FFIS(Federal Facilities Information System),STATE(State Environmental Laws and Statutes),and PADS(PCB Activity Data System). '411111r Date of Government Version:08/16/2014 Source: EPA Date Data Arrived at EDR:09/10/2014 Telephone: (215)814-5000 "1111/ Date Made Active in Reports:10/20/2014 Last EDR Contact:12/09/2014 Number of Days to Update:40 Next Scheduled EDR Contact:03/23/2015 low Data Release Frequency:Quarterly war RAATS: RCRA Administrative Action Tracking System Asp RCRA Administration Action Tracking System.RAATS contains records based on enforcement actions issued under RCRA pertaining to major violators and includes administrative and civil actions brought by the EPA.For administration r actions after September 30,1995,data entry in the RAATS database was discontinued. EPA will retain a copy of the database for historical records. It was necessary to terminate RAATS because a decrease in agency resources made it impossible to continue to update the information contained in the database. 4irr vow Air TC4182090.2s Page GR-17 war ®r+ �.r GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING Date of Government Version:04/17/1995 Source: EPA `s` Date Data Arrived at EDR:07/03/1995 Telephone: 202-564-4104 Date Made Active in Reports:08/07/1995 Last EDR Contact:06/02/2008 lay Number of Days to Update:35 Next Scheduled EDR Contact:09/01/2008 �wr Data Release Frequency:No Update Planned '411W RMP: Risk Management Plans When Congress passed the Clean Air Act Amendments of 1990,it required EPA to publish regulations and guidance for chemical accident prevention at facilities using extremely hazardous substances.The Risk Management Program Rule(RMP Rule)was written to implement Section 112(r)of these amendments.The rule,which built upon existing Nor industry codes and standards,requires companies of all sizes that use certain flammable and toxic substances to develop a Risk Management Program,which includes a(n):Hazard assessment that details the potential effects vow of an accidental release,an accident history of the last five years,and an evaluation of worst-case and alternative accidental releases;Prevention program that includes safety precautions and maintenance,monitoring,and employee 111W training measures;and Emergency response program that spells out emergency health care,employee training measures and procedures for informing the public and response agencies(e.g the fire department)should an accident occur. wr Date of Government Version:08/01/2014 Source: Environmental Protection Agency — Date Data Arrived at EDR:08/12/2014 Telephone: 202-564-8600 Date Made Active in Reports:11/06/2014 Last EDR Contact:10/27/2014 Number of Days to Update:86 Next Scheduled EDR Contact:02/09/2015 Data Release Frequency:Varies ter BRS: Biennial Reporting System +r• The Biennial Reporting System is a national system administered by the EPA that collects data on the generation and management of hazardous waste.BRS captures detailed data from two groups:Large Quantity Generators(LQG) Awe and Treatment,Storage,and Disposal Facilities. vrr Date of Government Version:12/31/2011 Source: EPA/NTIS Date Data Arrived at EDR:02/26/2013 Telephone: 800-424-9346 Now Date Made Active in Reports:04/19/2013 Last EDR Contact:11/26/2014 *go. of Days to Update:52 Next Scheduled EDR Contact:03/09/2015 Data Release Frequency:Biennially Air UIC: Underground Injection Control Wells .o. A listing of underground injection controls wells. Date of Government Version:11/04/2014 Source: Department of Mines,Minerals and Energy Al/ Date Data Arrived at EDR:11/05/2014 Telephone: 276-415-9700 Date Made Active in Reports:11/11/2014 Last EDR Contact:11/05/2014 mar Number of Days to Update:6 Next Scheduled EDR Contact:02/16/2015 Aur Data Release Frequency:Varies — DRYCLEANERS: Drycleaner List A listing of registered drycleaners. vr• Date of Government Version: 12/31/2012 Source: Department of Environmental Quality Date Data Arrived at EDR:03/06/2014 Telephone: 804-698-4407 Date Made Active in Reports:04/08/2014 Last EDR Contact:01/12/2015 Number of Days to Update:33 Next Scheduled EDR Contact:04/27/2015 • Data Release Frequency:Varies wr ENFORCEMENT: Enforcement Actions Data vow A listing of enforcement actions. Date of Government Version:09/09/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:09/10/2014 Telephone: 804-698-4031 *iv Date Made Active in Reports:11/10/2014 Last EDR Contact:12/08/2014 Number of Days to Update:61 Next Scheduled EDR Contact:03/23/2015 -- Data Release Frequency:Varies ANY lor mr yr err. wow TC4182090.2s Page GR-18 vise a.• GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING CEDS: Comprehensive Environmental Data System ur Virginia Water Protection Permits,Virginia Pollution Discharge System(point discharge)permits and Virginia Pollution Abatement(no point discharge)permits. v�r Date of Government Version:09/11/2014 Source: Department of Environmental Quality wr Date Data Arrived at EDR:09/12/2014 Telephone: 804-698-4077 Date Made Active in Reports:11/10/2014 Last EDR Contact:12/08/2014 — Number of Days to Update:59 Next Scheduled EDR Contact:03/23/2015 yr Data Release Frequency:Semi-Annually AIRS: Permitted Airs Facility List A listing of permitted Airs facilities. Date of Government Version:09/05/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:09/05/2014 Telephone: 804-698-4000 ier Date Made Active in Reports:11/07/2014 Last EDR Contact:12/01/2014 11110' Number of Days to Update:63 Next Scheduled EDR Contact:03/16/2015 Data Release Frequency:Varies +rr TIER 2: Tier 2 Information Listing air A listing of facilities which store or manufacture hazardous materials and submit a chemical inventory report. Date of Government Version: 12/31/2011 Source: Department of Environmental Quality Date Data Arrived at EDR:12/21/2012 Telephone: 804-698-4159 Date Made Active in Reports:02/19/2013 Last EDR Contact:01/09/2015 err Number of Days to Update:60 Next Scheduled EDR Contact:04/06/2015 *NW Data Release Frequency:Annually s,, INDIAN RESERV: Indian Reservations This map layer portrays Indian administered lands of the United States that have any area equal to or greater — than 640 acres. Date of Government Version:12/31/2005 Source: USGS +rr Date Data Arrived at EDR:12/08/2006 Telephone: 202-208-3710 Date Made Active in Reports:01/11/2007 Last EDR Contact: 11/07/2014 Number of Days to Update:34 Next Scheduled EDR Contact:01/26/2015 +ter Data Release Frequency:Semi-Annually --110, SCRD DRYCLEANERS: State Coalition for Remediation of Drycleaners Listing The State Coalition for Remediation of Drycleaners was established in 1998,with support from the U.S.EPA Office mar of Superfund Remediation and Technology Innovation. It is comprised of representatives of states with established drycleaner remediation programs.Currently the member states are Alabama,Connecticut,Florida, Illinois,Kansas, Minnesota, Missouri, North Carolina,Oregon,South Carolina,Tennessee,Texas,and Wisconsin. ,o. Date of Government Version:03/07/2011 Source: Environmental Protection Agency Date Data Arrived at EDR:03/09/2011 Telephone: 615-532-8599 -w Date Made Active in Reports:05/02/2011 Last EDR Contact:11/18/2014 Number of Days to Update:54 Next Scheduled EDR Contact:02/02/2015 VOW Data Release Frequency:Varies `or COAL ASH: Coal Ash Disposal Sites A listing of facilities with coal ash impoundments. low Date of Government Version:07/29/2009 Source: Department of Environmental Protection *d r Date Data Arrived at EDR:07/31/2009 Telephone: 804-698-4285 Date Made Active in Reports:08/21/2009 Last EDR Contact:12/08/2014 vire Number of Days to Update:21 Next Scheduled EDR Contact:03/23/2015 Data Release Frequency:Varies leo vow vrr +rr wr 'fir+ 41r► TC4182090.2s Page GR-19 w low .r. AMY GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING wr Financial Assurance 1: Financial Assurance Information Listing A listing of financial assurance information for underground storage tank facilities. Financial assurance is intended to ensure that resources are available to pay for the cost of closure,post-closure care,and corrective measures vow if the owner or operator of a regulated facility is unable or unwilling to pay. aw Date of Government Version:08/11/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:08/14/2014 Telephone: 804-698-4205 Date Made Active in Reports:09/19/2014 Last EDR Contact:11/03/2014 Number of Days to Update:36 Next Scheduled EDR Contact:IMO/ Data Release Frequency:Varies v� EPA WATCH LIST: EPA WATCH LIST EPA maintains a"Watch List"to facilitate dialogue between EPA,state and local environmental agencies on enforcement matters relating to facilities with alleged violations identified as either significant or high priority. Being low on the Watch List does not mean that the facility has actually violated the law only that an investigation by EPA or a state or local environmental agency has led those organizations to allege that an unproven violation — has in fact occurred.Being on the Watch List does not represent a higher level of concern regarding the alleged violations that were detected,but instead indicates cases requiring additional dialogue between EPA,state and `es, local agencies-primarily because of the length of time the alleged violation has gone unaddressed or unresolved. y,,, Date of Government Version:08/30/2013 Source: Environmental Protection Agency Date Data Arrived at EDR:03/21/2014 Telephone: 617-520-3000 — Date Made Active in Reports:06/17/2014 Last EDR Contact:11/14/2014 Number of Days to Update:88 Next Scheduled EDR Contact:02/23/2015 low Data Release Frequency:Quarterly COAL ASH EPA: Coal Combustion Residues Surface Impoundments List A listing of coal combustion residues surface impoundments with high hazard potential ratings. Date of Government Version:07/01/2014 Source: Environmental Protection Agency Aar Date Data Arrived at EDR:09/10/2014 Telephone: N/A Date Made Active in Reports:10/20/2014 Last EDR Contact: 12/12/2014 w Number of Days to Update:40 Next Scheduled EDR Contact:03/23/2015 Data Release Frequency:Varies PCB TRANSFORMER: PCB Transformer Registration Database The database of PCB transformer registrations that includes all PCB registration submittals. Date of Government Version:02/01/2011 Source: Environmental Protection Agency Date Data Arrived at EDR:10/19/2011 Telephone: 202-566-0517 var Date Made Active in Reports:01/10/2012 Last EDR Contact:10/31/2014 Number of Days to Update:83 Next Scheduled EDR Contact:02/09/2015 wr Data Release Frequency:Varies vir• Financial Assurance 2: Financial Assurance Information listing Solid waste financial assurance information. IOW Date of Government Version: 11/03/2014 Source: Department of Environmental Quality Date Data Arrived at EDR:11/04/2014 Telephone: 804-698-4123 Date Made Active in Reports:11/11/2014 Last EDR Contact:11/03/2014 ''r' Number of Days to Update:7 Next Scheduled EDR Contact:02/16/2015 Data Release Frequency:Varies US FIN ASSUR: Financial Assurance Information All owners and operators of facilities that treat,store,or dispose of hazardous waste are required to provide Aar proof that they will have sufficient funds to pay for the clean up,closure,and post-closure care of their facilities. Date of Government Version:09/04/2014 Source: Environmental Protection Agency Ay" Date Data Arrived at EDR:09/04/2014 Telephone: 202-566-1917 Asir Date Made Active in Reports:10/20/2014 Last EDR Contact:11/11/2014 Number of Days to Update:46 Y p Next Scheduled EDR Contact:03/02/2015 err Data Release Frequency:Quarterly NOW vow wr+� TC4182090.2s Page GR-20 Air wrr ASV GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING US AIRS MINOR: Air Facility System Data r"' A listing of minor source facilities. +rr Date of Government Version:10/16/2014 Source: EPA Date Data Arrived at EDR:10/31/2014 Telephone: 202-564-2496 'ay Date Made Active in Reports: 11/17/2014 Last EDR Contact:12/23/2014 Number of Days to Update:17 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Annually - US AIRS(AFS): Aerometric Information Retrieval System Facility Subsystem(AFS) vow The database is a sub-system of Aerometric Information Retrieval System(AIRS).AFS contains compliance data on air pollution point sources regulated by the U.S.EPA and/or state and local air regulatory agencies.This information comes from source reports by various stationary sources of air pollution,such as electric power plants, steel mills,factories,and universities,and provides information about the air pollutants they produce.Action, air program,air program pollutant,and general level plant data.It is used to track emissions and compliance data from industrial plants. Date of Government Version: 10/16/2014 Source: EPA Date Data Arrived at EDR:10/31/2014 Telephone: 202-564-2496 Date Made Active in Reports:11/17/2014 Last EDR Contact: 12/23/2014 vow Number of Days to Update:17 Next Scheduled EDR Contact:04/13/2015 Data Release Frequency:Annually FEDLAND: Federal and Indian Lands low Federally and Indian administrated lands of the United States. Lands included are administrated by:Army Corps of Engineers,Bureau of Reclamation,National Wild and Scenic River, National Wildlife Refuge, Public Domain Land, AO" Wilderness,Wilderness Study Area,Wildlife Management Area, Bureau of Indian Affairs,Bureau of Land Management, Department of Justice,Forest Service,Fish and Wildlife Service, National Park Service. Amir Date of Government Version: 12/31/2005 Source: U.S.Geological Survey Date Data Arrived at EDR:02/06/2006 Telephone: 888-275-8747 Date Made Active in Reports:01/11/2007 Last EDR Contact: 11/07/2014 Nr Number of Days to Update:339 Next Scheduled EDR Contact:01/26/2015 Data Release Frequency:N/A vow COAL ASH DOE: Sleam-Electric Plan Operation Data — A listing of power plants that store ash in surface ponds. vier Date of Government Version: 12/31/2005 Source: Department of Energy Date Data Arrived at EDR:08/07/2009 Telephone: 202-586-8719 Ater Date Made Active in Reports:10/22/2009 Last EDR Contact: 10/17/2014 Number of Days to Update:76 Next Scheduled EDR Contact:,41111, Data Release Frequency:Varies `so 2020 COR ACTION: 2020 Corrective Action Program List The EPA has set ambitious goals for the RCRA Corrective Action program by creating the 2020 Corrective Action +o. Universe.This RCRA cleanup baseline includes facilities expected to need corrective action.The 2020 universe contains a wide variety of sites.Some properties are heavily contaminated while others were contaminated but have since been cleaned up.Still others have not been fully investigated yet,and may require little or no remediation. o, Inclusion in the 2020 Universe does not necessarily imply failure on the part of a facility to meet its RCRA obligations. Date of Government Version:11/11/2011 Source: Environmental Protection Agency Date Data Arrived at EDR:05/18/2012 Telephone: 703-308-4044 Date Made Active in Reports:05/25/2012 Last EDR Contact: 11/14/2014 Number of Days to Update:7 Next Scheduled EDR Contact:02/23/2015 1110, Data Release Frequency:Varies .,r LEAD SMELTER 2: Lead Smelter Sites A list of several hundred sites in the U.S.where secondary lead smelting was done from 1931 and 1964.These sites +wr may pose a threat to public health through ingestion or inhalation of contaminated soil or dust "ow 4+. • wYr 4111r «rr TC4182090.2s Page GR-21 �ww Aar GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING low Date of Government Version:04/05/2001 Source: American Journal of Public Health Date Data Arrived at EDR:10/27/2010 Telephone: 703-305-6451 Date Made Active in Reports:12/02/2010 Last EDR Contact:12/02/2009 Nor Number of Days to Update:36 Next Scheduled EDR Contact:N/A Ala" Data Release Frequency:No Update Planned *NV LEAD SMELTER 1: Lead Smelter Sites A listing of former lead smelter site locations. r` Date of Government Version:06/04/2014 Source: Environmental Protection Agency Nor Date Data Arrived at EDR:06/12/2014 Telephone: 703-603-8787 Date Made Active in Reports:07/28/2014 Last EDR Contact:01/05/2015 VINIF Number of Days to Update:46 Next Scheduled EDR Contact:04/20/2015 Data Release Frequency:Varies rrr PRP: Potentially Responsible Parties low A listing of verified Potentially Responsible Parties vw Date of Government Version:10/25/2013 Source: EPA Date Data Arrived at EDR:10/17/2014 Telephone: 202-564-6023 Now Date Made Active in Reports:10/20/2014 Last EDR Contact: 12/29/2015 Number of Days to Update:3 Next Scheduled EDR Contact:04/13/2015 "o° Data Release Frequency:Quarterly EDR HIGH RISK HISTORICAL RECORDS wr, EDR Exclusive Records Quip EDR MGP: EDR Proprietary Manufactured Gas Plants 'o"' The EDR Proprietary Manufactured Gas Plant Database includes records of coal gas plants(manufactured gas plants) compiled by EDR's researchers.Manufactured gas sites were used in the United States from the 1800's to 1950's to produce a gas that could be distributed and used as fuel.These plants used whale oil,rosin,coal,or a mixture 11111W of coal,oil,and water that also produced a significant amount of waste. Many of the byproducts of the gas production, such as coal tar(oily waste containing volatile and non-volatile chemicals),sludges,oils and other compounds are potentially hazardous to human health and the environment.The byproduct from this process was frequently disposed of directly at the plant site and can remain or spread slowly,serving as a continuous source of soil «+ and groundwater contamination. Date of Government Version:N/A Source: EDR, Inc. Date Data Arrived at EDR:N/A Telephone: N/A Nor Date Made Active in Reports:N/A Last EDR Contact:N/A Number of Days to Update:N/A Next Scheduled EDR Contact:N/A Nor Data Release Frequency:No Update Planned Nor EDR US Hist Auto Stat: EDR Exclusive Historic Gas Stations EDR has searched selected national collections of business directories and has collected listings of potential ar gas station/filling station/service station sites that were available to EDR researchers. EDR's review was limited to those categories of sources that might,in EDR's opinion,include gas station/filling station/service station — establishments.The categories reviewed included,but were not limited to gas,gas station,gasoline station, filling station,auto,automobile repair,auto service station,service station,etc.This database falls within No a category of information EDR classifies as"High Risk Historical Records",or HRHR. EDR's HRHR effort presents unique and sometimes proprietary data about past sites and operations that typically create environmental concerns, Aar but may not show up in current government records searches. — Date of Government Version:N/A Source: EDR, Inc. Date Data Arrived at EDR:N/A Telephone: N/A '"" Date Made Active in Reports:N/A Last EDR Contact:N/A 1 NW Number of Days to Update:N/A Next Scheduled EDR Contact:N/A Data Release Frequency:Varies vr` Asir .ir w Awe *or TC4182090.2s Page GR-22 yr ANY GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING IOW EDR US Hist Cleaners: EDR Exclusive Historic Dry Cleaners "— EDR has searched selected national collections of business directories and has collected listings of potential dry cleaner sites that were available to EDR researchers. EDR's review was limited to those categories of sources that might,in EDR's opinion,include dry cleaning establishments.The categories reviewed included,but were VIO not limited to dry cleaners,cleaners, laundry,laundromat,cleaning/laundry,wash&dry etc.This database falls within a category of information EDR classifies as"High Risk Historical Records",or HRHR.EDR's HRHR effort presents unique and sometimes proprietary data about past sites and operations that typically create environmental concerns,but may not show up in current government records searches. `aw Date of Government Version:N/A Source: EDR, Inc. Date Data Arrived at EDR:N/A Telephone: N/A vrr Date Made Active in Reports:N/A Last EDR Contact:N/A woo Number of Days to Update:N/A Next Scheduled EDR Contact:N/A Data Release Frequency:Varies EDR RECOVERED GOVERNMENT ARCHIVES Amy— Exclusive Recovered Govt.Archives aw RGA LF: Recovered Government Archive Solid Waste Facilities List The EDR Recovered Government Archive Landfill database provides a list of landfills derived from historical databases Ayr— and includes many records that no longer appear in current government lists.Compiled from Records formerly available from the Department of Environmental Quality in Virgina. *VW Date of Government Version:N/A Source: Department of Environmental Quality — Date Data Arrived at EDR:07/01/2013 Telephone: N/A Date Made Active in Reports:01/20/2014 Last EDR Contact:06/01/2012 low Number of Days to Update:203 Next Scheduled EDR Contact:N/A �rwP° Data Release Frequency:Varies RGA LUST: Recovered Government Archive Leaking Underground Storage Tank "" The EDR Recovered Government Archive Leaking Underground Storage Tank database provides a list of LUST incidents derived from historical databases and includes many records that no longer appear in current government lists. 'VW Compiled from Records formerly available from the Department of Environmental Quality in Virgina and at the Regional VA Levels. Date of Government Version:N/A Source: Department of Environmental Quality *rr Date Data Arrived at EDR:07/01/2013 Telephone: N/A Date Made Active in Reports:01/15/2014 Last EDR Contact:06/01/2012 vow Number of Days to Update:198 Next Scheduled EDR Contact:N/A Data Release Frequency:Varies Are OTHER DATABASE(S) rrr� Depending on the geographic area covered by this report,the data provided in these specialty databases may or may not be .rr complete. For example,the existence of wetlands information data in a specific report does not mean that all wetlands in the ,rp, area covered by the report are included. Moreover,the absence of any reported wetlands information does not necessarily mean that wetlands do not exist in the area covered by the report. 44r► CT MANIFEST: Hazardous Waste Manifest Data ow Facility and manifest data.Manifest is a document that lists and tracks hazardous waste from the generator through transporters to a tsd facility. wr Date of Government Version:07/30/2013 Source: Department of Energy&Environmental Protection Date Data Arrived at EDR:08/19/2013 Telephone: 860-424-3375 Date Made Active in Reports:10/03/2013 Last EDR Contact: 11/17/2014 Number of Days to Update:45 Next Scheduled EDR Contact:03/02/2015 Data Release Frequency:No Update Planned wry air err IMP` ASV TC4182090.2s Page GR-23 gar wir .r GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING NJ MANIFEST: Manifest Information ` Hazardous waste manifest information. 'rr Date of Government Version:12/31/2011 Source: Department of Environmental Protection Date Data Arrived at EDR:07/19/2012 Telephone: N/A ar Date Made Active in Reports:08/28/2012 Last EDR Contact:01/12/2015 Number of Days to Update:40 Next Scheduled EDR Contact:04/27/2015 ""r` Data Release Frequency:Annually """" NY MANIFEST: Facility and Manifest Data Manifest is a document that lists and tracks hazardous waste from the generator through transporters to a TSD Vlifr facility. Date of Government Version:11/01/2014 Source: Department of Environmental Conservation Date Data Arrived at EDR:11/05/2014 Telephone: 518-402-8651 "r' Date Made Active in Reports:11/24/2014 Last EDR Contact:11/05/2014 Number of Days to Update:19 Next Scheduled EDR Contact:02/16/2015 Data Release Frequency:Annually PA MANIFEST: Manifest Information mo, Hazardous waste manifest information. Date of Government Version:12/31/2013 Source: Department of Environmental Protection Date Data Arrived at EDR:07/21/2014 Telephone: 717-783-8990 Date Made Active in Reports:08/25/2014 Last EDR Contact: 10/20/2014 'o++ Number of Days to Update:35 Next Scheduled EDR Contact:02/02/2015 Data Release Frequency:Annually RI MANIFEST: Manifest information Hazardous waste manifest information Date of Government Version: 12/31/2013 Source: Department of Environmental Management Date Data Arrived at EDR:07/15/2014 Telephone: 401-222-2797 'Now Date Made Active in Reports:08/13/2014 Last EDR Contact:11/26/2014 Number of Days to Update:29 Next Scheduled EDR Contact:03/09/2015 Air Data Release Frequency:Annually tor WI MANIFEST: Manifest Information �rw Hazardous waste manifest information. Date of Government Version:12/31/2013 Source: Department of Natural Resources 111111, Date Data Arrived at EDR:06/20/2014 Telephone: N/A low Date Made Active in Reports:08/07/2014 Last EDR Contact:12/12/2014 Number of Days to Update:48 Next Scheduled EDR Contact:03/30/2015 — Data Release Frequency:Annually wr Oil/Gas Pipelines: This data was obtained by EDR from the USGS in 1994. It is referred to by USGS as GeoData Digital Line Graphs from 1:100,000-Scale Maps. It was extracted from the transportation category including some oil,but primarily low gas pipelines. Sensitive Receptors: There are individuals deemed sensitive receptors due to their fragile immune systems and special sensitivity to environmental discharges. These sensitive receptors typically include the elderly,the sick,and children. While the location of all Vliff sensitive receptors cannot be determined,EDR indicates those buildings and facilities-schools,daycares,hospitals,medical centers, and nursing homes-where individuals who are sensitive receptors are likely to be located. vow AHA Hospitals: Source:American Hospital Association,Inc. Air Telephone:312-280-5991 The database includes a listing of hospitals based on the American Hospital Association's annual survey of hospitals. N r Medical Centers:Provider of Services Listing Source:Centers for Medicare&Medicaid Services "r° Telephone:410-786-3000 A listing of hospitals with Medicare provider number,produced by Centers of Medicare&Medicaid Services, a federal agency within the U.S.Department of Health and Human Services. ar .r .w. ver TC4182090.2s Page GR-24 mow Alit GOVERNMENT RECORDS SEARCHED/ DATA CURRENCY TRACKING w Nursing Homes 'OW Source:National Institutes of Health Telephone:301-594-6248 ter. Information on Medicare and Medicaid certified nursing homes in the United States. Public Schools Source:National Center for Education Statistics Telephone:202-502-7300 Aar The National Center for Education Statistics'primary database on elementary Nur and secondary public education in the United States. It is a comprehensive,annual,national statistical database of all public elementary and secondary schools and school districts,which contains data that are wr comparable across all states. Private Schools Source:National Center for Education Statistics Telephone:202-502-7300 The National Center for Education Statistics'primary database on private school locations in the United States. Daycare Centers:Licensed Facilities wrr Source:Department of Social Services err Telephone:804-692-1900 VOW Flood Zone Data: This data,available in select counties across the country,was obtained by EDR in 2003&2011 from the Federal „i. Emergency Management Agency(FEMA). Data depicts 100-year and 500-year flood zones as defined by FEMA. NWI: National Wetlands Inventory. This data,available in select counties across the country,was obtained by EDR in 2002,2005 and 2010 from the U.S.Fish and Wildlife Service. ASV A'® Scanned Digital USGS 7.5'Topographic Map(DRG) Source:United States Geologic Survey vow A digital raster graphic(DRG)is a scanned image of a U.S.Geological Survey topographic map.The map images are made by scanning published paper maps on high-resolution scanners.The raster image is georeferenced and fit to the Universal Transverse Mercator(UTM)projection. it IOW STREET AND ADDRESS INFORMATION — ©2010 Tele Atlas North America,Inc.All rights reserved. This material is proprietary and the subject of copyright protection and other intellectual property rights owned by or licensed to Tele Atlas North America, Inc. The use of this material is subject ar. to the terms of a license agreement. You will be held liable for any unauthorized copying or disclosure of this material. Virerr vwr +wr �rrr wr �.r qtr ANY +ar IOW TC4182090.2s Page GR-25 w w. GEOCHECK®- PHYSICAL SETTING SOURCE ADDENDUM IMF VINO r TARGET PROPERTY ADDRESS — MECHUMS TRESTLE 4294 THREE NOTCHED RD CHARLOTTESVILLE, VA 22901 err TARGET PROPERTY COORDINATES it Latitude(North): 38.0623-38°3'44.28" ,a. Longitude(West): 78.6489-78°38'56.04" Universal Tranverse Mercator: Zone 17 UTM X(Meters): 706264.8 UTM Y(Meters): 4215131.5 Elevation: 504 ft. above sea level virr USGS TOPOGRAPHIC MAP Target Property Map: 38078-A6 CROZET, VA 'e'v Most Recent Revision: 1997 EDR's GeoCheck Physical Setting Source Addendum is provided to assist the environmental professional in arr forming an opinion about the impact of potential contaminant migration. Assessment of the impact of contaminant migration generally has two principal investigative components: 441. 1. Groundwater flow direction, and 2. Groundwater flow velocity. Groundwater flow direction may be impacted by surface topography, hydrology, hydrogeology, characteristics of the soil, and nearby wells. Groundwater flow velocity is generally impacted by the nature of the geologic strata. Air NNW 41101, wr Nair ..r w. TC4182090.2s Page A-1 MOW wr GEOCHECK® - PHYSICAL SETTING SOURCE SUMMARY GROUNDWATER FLOW DIRECTION INFORMATION Ayr Groundwater flow direction for a particular site is best determined by a qualified environmental professional using site-specific well data. If such data is not reasonably ascertainable, it may be necessary to rely on other ''r" sources of information,such as surface topographic information, hydrologic information, hydrogeologic data collected on nearby properties, and regional groundwater flow information(from deep aquifers). fw �.r TOPOGRAPHIC INFORMATION Now Surface topography may be indicative of the direction of surficial groundwater flow. This information can be used to AO, assist the environmental professional in forming an opinion about the impact of nearby contaminated properties or, should contamination exist on the target property, what downgradient sites might be impacted. wr TARGET PROPERTY TOPOGRAPHY yr" General Topographic Gradient: General South Apr ,r SURROUNDING TOPOGRAPHY:ELEVATION PROFILES ur• rr Awe Z N o 0 10 o +Ylr C S e. 0 p .= N OAD �p vat A p p A vrr wrr w• North I South TP err mow Q INV •To' N Omi O W J r Np N V p 4 N d p m A p p N wr wV West I East '01111, TP Target Property Elevation:504 ft. 0 1/2 1 Miles wr Source:Topography has been determined from the USGS 7.5'Digital Elevation Model and should be evaluated on a relative(not an absolute)basis. Relative elevation information between sites of close proximity yaw should be field verified. vow TC4182090.2s Page A-2 wow ANW *NW 44110r 't11P ar►' GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY ler HYDROLOGIC INFORMATION — Surface water can act as a hydrologic barrier to groundwater flow. Such hydrologic information can be used to assist the environmental professional in forming an opinion about the impact of nearby contaminated properties or, should contamination exist on the target property,what downgradient sites might be impacted. Refer to the Physical Setting Source Map following this summary for hydrologic information(major waterways and bodies of water). NNW FEMA FLOOD ZONE FEMA Flood Target Property County Electronic Data ler ALBEMARLE, VA YES-refer to the Overview Map and Detail Map Flood Plain Panel at Target Property: 51003C -FEMA DFIRM Flood data gar Additional Panels in search area: Not Reported *ow NATIONAL WETLAND INVENTORY NWI Electronic wo, NWI Quad at Target Property Data Coverage CROZET YES-refer to the Overview Map and Detail Map IOW +�r HYDROGEOLOGIC INFORMATION Hydrogeologic information obtained by installation of wells on a specific site can often be an indicator of groundwater flow direction in the immediate area. Such hydrogeologic information can be used to assist the environmental professional in forming an opinion about the impact of nearby contaminated properties or, should contamination exist on the target property, what downgradient sites might be impacted. lor Site-Specific Hydrogeological Data": err Search Radius: 1.25 miles Status: Not found w AQUIFLOW® Search Radius: 1.000 Mile. 46. Nor EDR has developed the AQUIFLOW Information System to provide data on the general direction of groundwater flow at specific points. EDR has reviewed reports submitted by environmental professionals to regulatory Air authorities at select sites and has extracted the date of the report, groundwater flow direction as determined hydrogeologically, and the depth to water table. wr LOCATION GENERAL DIRECTION MAP ID FROM TP GROUNDWATER FLOW Not Reported NOW vrr vrr 41110, NNW °fir •©1996 Ste-specific hydrogeological data gathered by CERCLIS Alerts,Inc Bainbridge Island,WA All rights reserved All of the information and opinions presented are those of the cited EPA report(s),which were completed under a Comprehensive Environmental Response Compensation and Liability Information System(CERCLIS)investigation TC4182090.2s Page A-3 vow .rr NOW w i.r GEOCHECK® - PHYSICAL SETTING SOURCE SUMMARY GROUNDWATER FLOW VELOCITY INFORMATION `'"' Groundwater flow velocity information for a particular site is best determined by a qualified environmental professional using site specific geologic and soil strata data. If such data are not reasonably ascertainable, it may be necessary 'O'' to rely on other sources of information, including geologic age identification, rock stratigraphic unit and soil ow characteristics data collected on nearby properties and regional soil information. In general, contaminant plumes move more quickly through sandy-gravelly types of soils than silty-clayey types of soils. New GEOLOGIC INFORMATION IN GENERAL AREA OF TARGET PROPERTY — Geologic information can be used by the environmental professional in forming an opinion about the relative speed ler at which contaminant migration may be occurring. low ROCK STRATIGRAPHIC UNIT GEOLOGIC AGE IDENTIFICATION Era: Precambrian Category: Stratified Sequence System: Precambrian ,r,,, Series: Z Sedimentary rocks Code: Z (decoded above as Era,System&Series) -w Geologic Age and Rock Stratigraphic Unit Source: P.G. Schruben, R.E. Arndt and W.J. Bawiec, Geology tir of the Conterminous U.S. at 1:2,500,000 Scale-a digital representation of the 1974 P.B. King and H.M. Beikman Map, USGS Digital Data Series DDS- 11 (1994). r.. +err vrr NNW yr yr yr VOW +r vrr NNW rir Vr. TC4182090.2s Page A-4 4i hr SSURGO SOIL MAP - 4182090.2s k' 13 13 1 \ 1 ) z --� -� \ 6' 10 7 6 • ° g' `------" 4 9 1 y._ - IOW 13 ,° / 2 i �10 (\N 6/ } 12 8 /(17 , 17 g / / i / \ r * Target Property ^nay A/ SSURGO Soil Water ! I 0 0 0 SITE NAME: Mechums Trestle CLIENT: HydroGeo Environmental LLC ADDRESS: 4294 Three Notched Rd CONTACT: Ernest Beasley Charlottesville VA 22901 INQUIRY#: 4182090.2s LAT/LONG: 38.0623/78.6489 DATE: January 14,2015 4:41 pm Copyright cp 2015 EDR,Inc.©2010 Tele Atlas Re l.07/2009. NV 3 GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY DOMINANT SOIL COMPOSITION IN GENERAL AREA OF TARGET PROPERTY IMO The U.S. Department of Agriculture's(USDA)Soil Conservation Service(SCS)leads the National Cooperative Soil Survey(NCSS)and is responsible for collecting, storing, maintaining and distributing soil survey information for privately owned lands in the United States. A soil map in a soil survey is a representation of soil patterns IVO in a landscape.The following information is based on Soil Conservation Service SSURGO data. vr+ "NW Soil Map ID: 1 Now Soil Component Name: Toccoa vow Soil Surface Texture: fine sandy loam vey Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, *rr moderately well and well drained soils with moderately coarse textures. w Soil Drainage Class: Moderately well drained Nov Hydric Status: Partially hydric yaw -*op, Potential-Uncoated Steel: Low .w, Depth to Bedrock Min: >0 inches "NW Depth to Watertable Min: > 114 inches vow Soil Layer Information Ale Saturated Boundary Classification hydraulic err Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction low micro m/sec (pH) 1 0 inches 9 inches fine sandy loam Silt-Clay FINE-GRAINED Max:42 Max:6.5 law Materials(more SOILS,Silts and Min: 14 Min:5.1 than 35 pct. Clays(liquid passing No. limit less than V►' 200),Silty 50%),silt. Soils. IOW 2 9 inches 66 inches sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:6.5 Materials(more SOILS,Sands, Min:14 Min:5.1 tow than 35 pct. Sands with fines, passing No. Silty Sand. lw 200),Silty Soils. +11/ law rrr► Soil Map ID:2 lay Soil Component Name: Culpeper o, Soil Surface Texture: clay loam r Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward `'"` movement of water, or soils with moderately fine or fine textures. isio" Soil Drainage Class: Well drained vw TC4182090.2s Page A-6 vow air triw IOW GEOCHECK® - PHYSICAL SETTING SOURCE SUMMARY viw Hydric Status: Not hydric *ow Corrosion Potential-Uncoated Steel: Moderate Depth to Bedrock Min: >114 inches NNW Depth to Watertable Min: >0 inches Now ler Soil Layer Information vow Boundary Classification Saturated hydraulic +rr. Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) 1 0 inches 7 inches clay loam Silt-Clay Not reported Max:42 Max:5.5 low Materials(more Min:14 Min:4.5 than 35 pct. vow passing No. 200),Silty +rr, Soils. 2 7 inches 29 inches clay Silt-Clay FINE-GRAINED Max:14 Max:5.5 err Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid err passing No. limit less than ✓ 200),Clayey 50%),silt. Soils. 3 29 inches 37 inches sandy clay loam Silt-Clay COARSE-GRAINED Max:14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 err than 35 pct. Sands with fines, passing No. Clayey sand. NOY 200),Clayey Soils. 4 37 inches 44 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 'fw than 35 pct. Sands with fines, passing No. Clayey sand. ia"` 200),Silty COARSE-GRAINED Soils. SOILS,Sands, Sands with fines, o, Silty Sand. 5 44 inches 48 inches bedrock Not reported Not reported Max:42 Max: Min: Afar Min:1.4 +rr Soil Map ID:3 low Soil Component Name: Water lw ar Soil Surface Texture: clay loam y,. Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water, or soils with moderately fine or fine textures. Soil Drainage Class: TC4182090.2s Page A-7 41r9 409 GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY Hydric Status: Unknown +r✓ Corrosion Potential-Uncoated Steel: Not Reported yrr Depth to Bedrock Min: >0 inches sow Depth to Watertable Min: >0 inches vs, Ayr No Layer Information available. vier vow vow Soil Map ID:4 *iv Soil Component Name: Chewacla 'r+ Soil Surface Texture: silt loam — Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water,or soils with moderately fine or fine textures. ASV Soil Drainage Class: Somewhat poorly drained ,rr Hydric Status: Partially hydric Corrosion Potential-Uncoated Steel: High Depth to Bedrock Min: >0 inches — Depth to Watertable Min: >31 inches +Irr Soil Layer Information lr Saturated Boundary Classification hydraulic �1rr Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) 'hw 1 0 inches 7 inches silt loam Silt-Clay FINE-GRAINED Max: 14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:4.5 11110, than 35 pct. Clays(liquid passing No. limit less than III++ 200),Clayey 50%),Lean Clay Soils. yYr+ 2 7 inches 16 inches silt loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than +IrI/ 200),Clayey 50%),Lean Clay Soils. 3 16 inches 25 inches silty clay loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay low Soils. TC4182090.2s Page A-8 rIr vrr GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY Soil Layer Information Boundary Classification hydraulic Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) vow 4 25 inches 40 inches silty clay loam Silt-Clay FINE-GRAINED Max:14 Max:7.8 41w Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay lear Soils. 5 40 inches 59 inches silt loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay Soils. IMO Soil Map ID:5 yr Soil Component Name: Hazel Are Soil Surface Texture: loam Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water,or soils with moderately fine or fine textures. ow Soil Drainage Class: Excessively drained ""' Hydric Status: Not hydric low Corrosion Potential-Uncoated Steel: Low low Depth to Bedrock Min: >76 inches Aar Depth to Watertable Min: >0 inches tor +rr Soil Layer Information rr Boundary Classification Saturated hydraulic Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction ter micro m/sec (pH) low 1 0 inches 9 inches loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 11 1111, Materials(more SOILS,Silts and Min:14 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than low 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED SOILS,Silts and .rr Clays(liquid limit less than Amor _ 50%),silt. vrr w10, TC4182090.2s Page A-9 Aar +rr Now `k""` GEOCHEC J - PHYSICAL SETTING SOURCE SUMMARY vie vr► Soil Layer Information " Boundary Classification Saturated hydraulic NNW Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) law 2 9 inches 20 inches loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 Materials(more SOILS,Silts and Min: 14 Min:4.5 than 35 pct. Clays(liquid Nor passing No. limit less than Vow Soils.Silty 50%),Lean Clay. Soils. FINE-GRAINED SOILS,Silts and Clays(liquid Otiv limit less than 50%),silt. fir►' 3 20 inches 29 inches channery loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 Materials(more SOILS,Silts and Min:14 Min:4.5 ire than 35 pct. Clays(liquid passing No. limit less than r" 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED 4.er SOILS,Silts and Clays(liquid w limit less than 50%),silt. Ause 4 29 inches 33 inches bedrock Not reported Not reported Max:42 Max: Min: Min: 1.4 IOW IOW IOW Soil Map ID:6 4+109, vow Soil Component Name: Meadowville Soil Surface Texture:-0911W Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately moso textures. Soil Drainage Class: Well drained ISO Hydric Status: Partially hydric Corrosion Potential-Uncoated Steel: High err Depth to Bedrock Min: >0 inches low Depth to Watertable Min: > 122 inches ler MINO TC4182090.2s Page A-10 1 NSW 11 IOW - ""' GEOCHECW) - PHYSICAL SETTING SOURCE SUMMARY V IOW it Soil Layer Information Boundary Classification hydr utlic `— Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) view 1 0 inches 14 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: moir: Materials(more SOILS,Silts and Min: 14 4.5 than 35 pct. Clays(liquid Iwo passing No. limit less than 200),Silty 50%),Lean Clay Soils. 2 14 inches 46 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:4 4.5 r, than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay Soils. vow 3 46 inches 72 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:4 4.5 than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay wr Soils. err Soil Map ID:7 err Soil Component Name: Hiwassee low Soil Surface Texture: clay +rr Hydrologic Group: Class B- Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse textures. Soil Drainage Class: Well drained ler Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Moderate Depth to Bedrock Min: >0 inches Depth to Watertable Min: >0 inches r► MOW leer Affir IOW ANY ter. TC4182090.2s Page A-11 MOW GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY rr VW Soil Layer Information libr Boundary Classification hydraulic vow Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) IliW 1 7 inches 63 inches clay Silt-Clay. FINE-GRAINED Max:14 Max:6.5 4' Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid Itio passing No. limit less than 200),Silty 50%),silt. Soils. 2 0 inches 7 inches clay loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 NNW Materials(more SOILS,Silts and Min:4 Min:4.5 ler than 35 pct. Clays(liquid passing No. limit less than war' 200),Silty 50%),silt. Soils. +rr Var Atiov Soil Map ID:8 vrr Soil Component Name: McQueen Soil Surface Texture: loam vow Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward yr movement of water, or soils with moderately fine or fine textures. may Soil Drainage Class: Well drained `er Hydric Status: Not hydric — Corrosion Potential-Uncoated Steel: Moderate vw Depth to Bedrock Min: >0 inches VW Depth to Watertable Min: >168 inches "1110, Soil Layer Information CO CO OW • Boundary Classification Saturated hydraulic Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) 1 0 inches 7 inches loam Silt Clay FINE-GRAINED Max: 14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:3.6 • than 35 pct. Clays(liquid passing No. limit less than • 200),Clayey 50%),Lean Clay Soils. a law Aar 1r • 110 TC4182090.2s Page A-12 II err '`, GEOCHECKK - PHYSICAL SETTING SOURCE SUMMARY vw w me Soil Layer Information ilw Boundary Classification Saturated 111W Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) low 2 7 inches 42 inches clay Silt-Clay FINE-GRAINED Max:1.4 Max:5.5 w Materials(more SOILS,Silts and Min:0.42 Min:3.6 than 35 pct. Clays(liquid *ow passing No. limit less than 200),Clayey 50%),Lean Clay w✓ Soils. 3 42 inches 51 inches clay loam Silt-Clay FINE-GRAINED Max:4 Max:5.5 Materials(more SOILS,Silts and Min:1.4 Min:3.6 Now than 35 pct. Clays(liquid passing No. limit less than veer 200),Clayey 50%),Lean Clay Soils. wrr' 4 51 inches 63 inches sandy clay loam Silt-Clay FINE-GRAINED Max:4 Max:5.5 Materials(more SOILS,Silts and Min: 1.4 Min:3.6 than 35 pct. Clays(liquid passing No. limit less than 200),Clayey 50%),Lean Clay Soils. Soil Map ID:9 mew Soil Component Name: Riverview Soil Surface Texture: loam .r Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, `"" moderately well and well drained soils with moderately coarse textures. Now Soil Drainage Class: Well drained Hydric Status: Partially hydric Corrosion Potential-Uncoated Steel: Low Depth to Bedrock Min: >0 inches Depth to Watertable Min: >31 inches yr TC4182090.2s Page A-13 ., IirWi L GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY vior w 'ow Soil Layer Information `r" Boundary Classification Saturated ""` Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) vow 1 0 inches 11 inches loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 Nov Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than 200),Silty 50%),Lean Clay. law Soils. FINE-GRAINED SOILS,Silts and Itair Clays(liquid limit less than 50%),silt. le r 2 11 inches 35 inches silt loam Silt-Clay FINE-GRAINED Max:14 Max:6 Min: Materials(more SOILS,Silts and Min:4 4.5 Nov than 35 pct. Clays(liquid passing No. limit less than 41iW 200),Silty 50%),Lean Clay Soils. tr✓ 3 35 inches 59 inches silt loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:14 4.5 low than 35 pct. Clays(liquid passing No. limit less than 200),Silty 50%),silt. _ Soils. Soil Map ID: 10 wr w Soil Component Name: Ashe Soil Surface Texture: loam Aar ,r„ Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse Amy textures. Soil Drainage Class: Somewhat excessively drained Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Low Yrr Depth to Bedrock Min: >61 inches *ow Depth to Watertable Min: >0 inches *NW +rr� vrr rrr, vrr TC4182090.2s Page A-14 yr law vow rw GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY low Soil Layer Information Boundary Classification Saturated Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) Mir) 1 0 inches 9 inches loam Silt Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:14 3.6 than 35 pct. Clays(liquid goir passing No. limit less than 200),Silty 50%),Lean Clay. loor Soils. FINE-GRAINED yam, SOILS,Silts and Clays(liquid Nor limit less than 50%),silt. vas, 2 9 inches 18 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:14 3.6 *or than 35 pct. Clays(liquid passing No. limit less than Nor 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED SOILS,Silts and Clays(liquid limit less than `41W 50%),silt. 3 18 inches 24 inches sandy loam Granular COARSE-GRAINED Max:42 Max:6 Min: 140, materials(35 SOILS,Sands, Min:14 3.6 pct.or less Sands with fines, vr. passing No. Clayey sand. 200),Silty,or COARSE-GRAINED 'err Clayey Gravel SOILS,Sands, and Sand. Sands with fines, 'rrr Silty Sand. 4 24 inches 27 inches bedrock Not reported Not reported Max:42 Max: Min: vier Min:0 ley vor vow Soil Map ID: 11 •rw Soil Component Name: Riverview Soil Surface Texture: loam - Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse O textures. i` Soil Drainage Class: Well drained mar Hydric Status: Partially hydric Corrosion Potential-Uncoated Steel: Low Depth to Bedrock Min: >0 inches Depth to Watertable Min: >122 inches • TC4182090.2s Page A-15 tlr.r try tiov thy GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY Soil Layer Information *1110 Saturated Boundary Classification hydraulic 1110 Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) rrr✓ 1 0 inches 11 inches loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 141W Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid yr passing No. limit less than 200),Silty 50%),Lean Clay. low Soils. FINE-GRAINED SOILS,Silts and Clays(liquid rrr limit less than 50%),silt. vow 2 11 inches 35 inches silt loam Silt-Clay FINE-GRAINED Max:14 Max:6 Min: Materials(more SOILS,Silts and Min:4 4.5 '— than 35 pct. Clays(liquid passing No. limit less than +✓ 200),Silty 50%),Lean Clay Soils. """` 3 35 inches 59 inches silt loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min: 14 4.5 mw than 35 pct. Clays(liquid passing No. limit less than 200),Silty 50%),silt. ,r, Soils. MOW 'Or Soil Map ID: 12 few lo Soil Component Name: Hazel Now Soil Surface Texture: loam No Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water, or soils with moderately fine or fine textures. NOW Soil Drainage Class: Excessively drained 44rrr Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Low Depth to Bedrock Min: >76 inches Now ,ow Depth to Watertable Min: >0 inches Now VINO TC4182090.2s Page A-16 ir.y GEOCHECK® - PHYSICAL SETTING SOURCE SUMMARY letv w vtig° Soil Layer Information 'err Boundary Classification hydraulic Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) Nov 1 0 inches 9 inches loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 Materials(more SOILS,Silts and Min: 14 Min:4.5 err/ than 35 pct. Clays(liquid passing No. limit less than 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED ;fit SOILS,Silts and Clays(liquid 404 limit less than 50%),silt. 1110, 2 9 inches 20 inches loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 Materials(more SOILS,Silts and Min:14 Min:4.5 — than 35 pct. Clays(liquid passing No. limit less than - 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED SOILS,Silts and Clays(liquid air limit less than 50%),silt. 3 20 inches 29 inches channery loam Silt-Clay FINE-GRAINED Max:42 Max:5.5 Aar Materials(more SOILS,Silts and Min: 14 Min:4.5 than 35 pct. Clays(liquid 111W passing No. limit less than 200),Silty 50%),Lean Clay. yr Soils. FINE-GRAINED SOILS,Silts and viow Clays(liquid limit less than vow 50%),silt. 4 29 inches 33 inches bedrock Not reported Not reported Max:42 Max: Min: yr Min:1.4 moo Arr Soil Map ID: 13 4rw Soil Component Name: Hayesville — Soil Surface Texture: fine sandy loam Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse textures. Soil Drainage Class: Well drained IWO *N Now Air TC4182090.2s Page A-17 tor t GEOCHECKK - PHYSICAL SETTING SOURCE SUMMARY w, Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Moderate Depth to Bedrock Min: >0 inches Depth to Watertable Min: >0 inches tier Soil Layer Information 0, Boundary Classification Saturated hydraulic +rrr Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro rn/sec (pH) w 1 83 inches 87 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:6 Min: Syr Materials(more SOILS,Sands, Min: 14 3.6 than 35 pct. Sands with fines, passing No. Silty Sand. 200),Silty Soils. 2 0 inches 7 inches clay loam Silt-Clay FINE-GRAINED Max: 14 Max:6.5 '— Materials(more SOILS,Silts and Min:4 Min:3.6 than 35 pct. Clays(liquid Vow passing No. limit less than 200),Silty 50%),silt. Soils. „r 3 7 inches 57 inches clay Silt-Clay FINE-GRAINED Max:14 Max:6 Min: Materials(more SOILS,Silts and Min:4 3.6 vow than 35 pct. Clays(liquid passing No. limit less than +Mr 200),Silty 50%),silt. Soils. mow 4 57 inches 83 inches sandy clay loam Silt-Clay FINE-GRAINED Max: 14 Max:6 Min: Materials(more SOILS,Silts and Min:4 3.6 "- than 35 pct. Clays(liquid passing No. limit less than 200),Silty 50%),silt. Soils. Nor Nov Soil Map ID: 14 Nee Soil Component Name: Ashe +`rr Soil Surface Texture: loam VIP Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, vow moderately well and well drained soils with moderately coarse Aar textures. Soil Drainage Class: Somewhat excessively drained vow vb. VOW wr. Vrr Vor TC4182090.2s Page A-18 vow vow vir +Irll� Noe GEOCHECt 't' - PHYSICAL SETTING SOURCE SUMMARY Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Low Depth to Bedrock Min: >61 inches mer Depth to Watertable Min: >0 inches w, ,■► Soil Layer Information vliov Boundary Classification Saturated hydraulic oalo Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) 1 0 inches 9 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: VINO Materials(more SOILS,Silts and Min:14 3.6 than 35 pct. Clays(liquid +wr passing No. limit less than 200),Silty 50%),Lean Clay. 'ir► Soils. FINE-GRAINED SOILS,Silts and Clays(liquid limit less than Niv 50%),silt. *or 2 9 inches 18 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Silts and Min:14 3.6 than 35 pct. Clays(liquid passing No. limit less than ___ 200),Silty 50%),Lean Clay. Soils. FINE-GRAINED +rrr SOILS,Silts and Clays(liquid limit less than 50%),silt. 3 18 inches 24 inches sandy loam Granular COARSE-GRAINED Max:42 Max:6 Min: materials(35 SOILS,Sands, Min:14 3.6 pct.or less Sands with fines, passing No. Clayey sand. 200),Silty,or COARSE-GRAINED Clayey Gravel SOILS,Sands, and Sand. Sands with fines, Silty Sand. 4 24 inches 27 inches bedrock Not reported Not reported Max:42 Max: Min: Min:0 rw Soil Map ID: 15 Soil Component Name: Culpeper Nvir ,o„ Soil Surface Texture: fine sandy loam wr• Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water, or soils with moderately fine or fine textures. INV Soil Drainage Class: Well drained or Aaw '1Mr TC4182090.2s Page A-19 awe +rr tow two 1 ilw'` GEOCHECK° — PHYSICAL SETTING SOURCE SUMMARY lr NtiV Hydric Status: Not hydric Air Corrosion Potential-Uncoated Steel: Moderate Nor Depth to Bedrock Min: >114 inches low Depth to Watertable Min: >0 inches law iiir Soil Layer Information r Boundary Classification Saturated hydraulic lee Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) lir 1 0 inches 7 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:5.5 iloo Materials(more SOILS,Sands, Min:14 Min:4.5 than 35 pct. Sands with fines, ib►' passing No. Clayey sand. 200),Silty COARSE-GRAINED Irr Soils. SOILS,Sands, Sands with fines, M' Silty Sand. 2 7 inches 29 inches clay Silt-Clay FINE-GRAINED Max:14 Max:5.5 NW' Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid Ise passing No. limit less than 200),Clayey 50%),silt. Jose Soils. low 3 29 inches 37 inches sandy clay loam Silt-Clay COARSE-GRAINED Max:14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 Ilifeo than 35 pct. Sands with fines, passing No. Clayey sand. V1r+ 200),Clayey Soils. 460, 4 37 inches 44 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 W than 35 pct. Sands with fines, passing No. Clayey sand. 200),Silty COARSE-GRAINED Soils. SOILS,Sands, Sands with fines, Silty Sand. 5 44 inches 48 inches bedrock Not reported Not reported Max:42 Max: Min: kw Min:1.4 1 tit i 4161 i 111. Soil Map ID: 16 1 OW Soil Component Name: Culpeper 1 Soil Surface Texture: fine sandy loam ' frill Hydrologic Group: Class C-Slow infiltration rates. Soils with layers impeding downward movement of water, or soils with moderately fine or fine textures. Soil Drainage Class: Well drained it 1 .Illit# TC4182090.2s Page A-20 1 41111 i I Lo I (1110 Obi 1 41.1 GEOCHEC - PHYSICAL SETTING SOURCE SUMMARY to 1 Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Moderate I Depth to Bedrock Min: > 114 inches S Depth to Watertable Min: >0 inches Soil Layer Information .r Boundary Classification Saturated hydraulic +.r• Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) Now 1 0 inches 7 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:5.5 yr„ Materials(more SOILS,Sands, Min:14 Min:4.5 than 35 pct. Sands with fines, Nor passing No. Clayey sand. 200),Silty COARSE-GRAINED 'k Soils. SOILS,Sands, Sands with fines, V/1l✓ Silty Sand. 40 2 7 inches 29 inches clay Silt-Clay FINE-GRAINED Max: 14 Max:5.5 Materials(more SOILS,Silts and Min:4 Min:4.5 than 35 pct. Clays(liquid passing No. limit less than rrr 200),Clayey 50%),silt. Soils. ye 3 29 inches 37 inches sandy clay loam Silt-Clay COARSE-GRAINED Max:14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 'imor than 35 pct. Sands with fines, passing No. Clayey sand. +rrr 200),Clayey Soils. - 4 37 inches 44 inches fine sandy loam Silt-Clay COARSE-GRAINED Max: 14 Max:5.5 Materials(more SOILS,Sands, Min:4 Min:4.5 Ile than 35 pct. Sands with fines, passing No. Clayey sand. low 200),Silty COARSE-GRAINED VW Soils. SOILS,Sands, Sands with fines, vow Silty Sand. 5 44 inches 48 inches bedrock Not reported Not reported Max:42 Max: Min: wo Min:1.4 vrr Noy Soil Map ID: 17 Soil Component Name: Buncombe Nor VW Soil Surface Texture: loamy sand Hydrologic Group: Class A-High infiltration rates. Soils are deep, well drained to excessively drained sands and gravels. Army Soil Drainage Class: Excessively drained mew •i.r, Now low TC4182090.2s Page A-21 rr+ 1110 GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY Hydric Status: Partially hydric vrr Corrosion Potential-Uncoated Steel: Low vow Depth to Bedrock Min: >0 inches .r Depth to Watertable Min: >0 inches vow +w Soil Layer Information 'r' Boundary Classification Saturated hydraulic wry Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) 1 0 inches 9 inches loamy sand Granular COARSE-GRAINED Max:141 Max:6.5 materials(35 SOILS,Sands, Min:42 Min:4.5 pct.or less Sands with fines, low passing No. Silty Sand. 200),Silty,or vow Clayey Gravel and Sand. 2 9 inches 42 inches sand Granular COARSE-GRAINED Max:141 Max:6.5 materials(35 SOILS,Sands, Min:42 Min:4.5 IIW pct.or less Sands with fines, passing No. Silty Sand. 200),Silty,or Clayey Gravel and Sand. 3 42 inches 63 inches loamy sand Granular COARSE-GRAINED Max: 141 Max:6.5 materials(35 SOILS,Sands, Min:42 Min:4.5 *NO pct.or less Sands with fines, passing No. Silty Sand. +r1✓ 200),Silty,or Clayey Gravel mie and Sand. w °IOW Soil Map ID: 18 +rr Soil Component Name: Hayesville vow Soil Surface Texture: fine sandy loam Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse textures. vow Soil Drainage Class: Well drained Hydric Status: Not hydric W Corrosion Potential-Uncoated Steel: Moderate Depth to Bedrock Min: >0 inches Depth to Watertable Min: >0 inches I kV TC4182090.2s Page A-22 Lie liof GEOCHECI z' - PHYSICAL SETTING SOURCE SUMMARY war Soil Layer Information `" Boundary Classification hydraulic vise Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction micro m/sec (pH) vise 1 83 inches 87 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:6 Min: twit Materials(more SOILS,Sands, Min:14 3.6 than 35 pct. Sands with fines, passing No. Silty Sand. 200),Silty Soils. tie 2 0 inches 7 inches loam Silt-Clay FINE-GRAINED Max:42 Max:6.5 Materials(more SOILS,Silts and Min:14 Min:3.6 than 35 pct. Clays(liquid passing No. limit less than `rw 200),Silty 50%),silt. Soils. *so 3 7 inches 57 inches clay Silt-Clay FINE-GRAINED Max:14 Max:6 Min: Materials(more SOILS,Silts and Min:4 3.6 than 35 pct. Clays(liquid passing No. limit less than '— 200),Silty 50%),silt. , � Soils. 4 57 inches 83 inches sandy clay loam Silt-Clay FINE-GRAINED Max:14 Max:6 Min: 41r+ Materials(more SOILS,Silts and Min:4 3.6 than 35 pct. Clays(liquid - passing No. limit less than 200),Silty 50%),silt. Soils. NNW +ire Soil Map ID: 19 ,,, Soil Component Name: Hayesville oy Soil Surface Texture: fine sandy loam low Hydrologic Group: Class B-Moderate infiltration rates. Deep and moderately deep, moderately well and well drained soils with moderately coarse Ilasv textures. Soil Drainage Class: Well drained IWO Hydric Status: Not hydric Corrosion Potential-Uncoated Steel: Moderate gip Depth to Bedrock Min: >0 inches Amy Depth to Watertable Min: >0 inches ..• vrw wr TC4182090.2s Page A-23 'fir I giro GEOCHECI(" - PHYSICAL SETTING SOURCE SUMMARY Soil Layer Information Boundary Classification hydraulic "r' Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil conductivity Soil Reaction vow micro m/sec (pH) 1 83 inches 87 inches fine sandy loam Silt-Clay COARSE-GRAINED Max:42 Max:6 Min: Materials(more SOILS,Sands, Min:14 3.6 vrr than 35 pct. Sands with fines, passing No. Silty Sand. 200),Silty Soils. *ow 2 0 inches 7 inches clay loam Silt-Clay FINE-GRAINED Max:14 Max:6.5 Materials(more SOILS,Silts and Min:4 Min:3.6 r than 35 pct. Clays(liquid passing No. limit less than vow 200),Silty 50%),silt. Soils. 3 7 inches 57 inches clay Silt-Clay FINE-GRAINED Max: 14 Max:6 Min: Materials(more SOILS,Silts and Min:4 3.6 than 35 pct. Clays(liquid rlw� passing No. limit less than 200),Silty 50%),silt. Soils. 4 57 inches 83 inches sandy clay loam Silt-Clay FINE-GRAINED Max:14 Max:6 Min: Materials(more SOILS,Silts and Min:4 3.6 Now than 35 pct. Clays(liquid low passing No. limit less than 200),Silty 50%),silt. — Soils. low low LOCAL/REGIONAL WATER AGENCY RECORDS wir EDR Local/Regional Water Agency records provide water well information to assist the environmental „w professional in assessing sources that may impact ground water flow direction, and in forming an opinion about the impact of contaminant migration on nearby drinking water wells. r WELL SEARCH DISTANCE INFORMATION woo DATABASE SEARCH DISTANCE(miles) .�,. Federal USGS 1.000 Federal FRDS PWS Nearest PWS within 1 mile +ww State Database 1.000 `err FEDERAL USGS WELL INFORMATION '1110. LOCATION MAP ID WELL ID FROM TP vow b0. wrr yr TC4182090.2s Page A-24 kw' vow wire 1 INF Air Ale GEOCHECK° - PHYSICAL SETTING SOURCE SUMMARY FEDERAL USGS WELL INFORMATION 'r LOCATION 41 MAP ID WELL ID FROM TP No Wells Found afar FEDERAL FRDS PUBLIC WATER SUPPLY SYSTEM INFORMATION +rr LOCATION MAP ID WELL ID FROM TP +rr 1 VA2003050 1/2-1 Mile WNW low Note:PWS System location is not always the same as well location. wr — STATE DATABASE WELL INFORMATION ,�, LOCATION MAP ID WELL ID FROM TP view No Wells Found err wr tirr IOW IWO • +rr e • • • • i S i S 40 TC4182090.2s Page A-25 S VOW PHYSICAL SETTING SOURCE MAP - 4182090.2s 1� Gam \ V vie: _S---,1-1- . , -- ,-- _ _i\\ , .\,_. , _ , ,,__ -- . _% _\/\ \ \ \ ___----_--1_,,_ fir--..\\," 2 '' c,-/l..-, ' L___e ‘--7 ///1:,,,---7:47:7\ ---)) ',Ai'k. "" Pil i \__, Z----, ,,_,,, isv, _ ;r-------/ , .411101 L‘, ,.,) 0 / r, fpccio ' „_._...,.__,., ‘,.. / C) 1 Ilie / 1 ' pod/ - .21----H7,--, ; , i : , /-\ Ai, 14W 41112-91- Ay J \-_,,, ,,./> o yv 4 +rte \� �� „.e���� '`', L� \ �, � law _14 '111,. pf ��- - , -� \ tio 4e -1 1 $ . --- 1 - --a:IiiIIIRT.,.9".. t WRIN......., ' .........■, , \ 4 '41.0 ,‘V, t, z- -,,,b, ......,____ ° ....Aliorioli-imrdz' ilt-WV/ 41:11 `.4,H1*...,..,N.....e)''yr 7 i 5-\ Ole■N 1 4)ftic.1" (( Arip ` 4111•1 f--' SC--. K C-- / )11 k‘leiN-41,1,,,i , __77.-,.,4•A„!, .,4 7 c_s___:7'N_SA0A4i:,...' NW t,, 7,5 / ''''\ ..(-:.,.. i a ,*- -----4 f e*. c\ - IN..i , f--c -- ,'''' is / .4.0 ,____.,7_ i---1 NIIY ,-*— ' \ _m0411111 , .\ kw --( 1J ( '', .'--41)91f ' ' ‘11° lit- \01°2_) 1 \ ,) 64 IM 1 v \ N��\�-�\ 'L ��' � � Ay , � ( � e i 1 ; , , - "Al , -- fir 0 rr a° ) c____ _ qo t>41\p , . ) 0 --- ) , , ' C 401111.5Ak - yA y y\\ yA A ( \�, _�y\ H willgrilk Cr A County Boundary 0 1/A 1/2 1 M Iles 46 /v Major Roads Groundwater Flow Direction it_ © Earthquake epicenter,Richter 5 or greater (c ) Indeterminate Groundwater Flow at Location �� Y © Water Wells (G v) Groundwater Flow Varies at Location Public Water Supply Wells (H D) Closest Hydrogeological Data • Cluster of Multiple Icons Cr Ow ADDRESS:NAME: 4294 Three Notched CONTACT: Ernest Beasley hed Rd I CLIENT: HydroGeo Environmental LLC RV Charlottesville VA 22901 INQUIRY#: 4182090.2s LAT/LONG: 38.0623/78.6489 DATE: January 14,2015 4:41 pm Copyright in 2015 EDR,Inc�.2010 Tale Atlas Hal. 07/2009. 1 GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS AIIIIr Map ID Direction Distance Elevation Database EDR ID Number vow 1 - WNW FRDS PWS VA2003050 1/2-1 Mile Higher Epa region: 03 State: VA `r` Pwsid: VA2003050 Pwsname: ACSA CROZET City served: Not Reported State served: VA Zip served: Not Reported Fips county: 51003 low Status: Active Pop srvd: 7538 low Pwssvcconn: 2738 Source: Purch_surface_water Pws type: CWS Owner: Local_Govt war Contact: O'CONNELL,GARY Contactor gname: O'CONNELL,GARY — Contact phone: 434-977-4511 Contact addressl: 168 Spotnap Road Contact address2: Not Reported Contact city: CHARLOTTESVILLE `•••■ Contact state: VA Contact zip: 22911-8690 Activity code: A AIW *NW Location Information: Name: ACSA CROZET Pwstypcd: CWS Primsrccd: SWP vow Popserved: 7718 Add1: 168 SPOTNAP ROAD err Add2: Not Reported City: CHARLOTTESVILLE State: VA +rr Zip: 22911-8690 Phone: 434-977-4511 Cityserv: Not Reported Cntyserv: Albemarle 4se, Stateserv: VA Zipserv: Not Reported `ir Enforcement Information: Violation id: 2788108 Orig cd: S "" Enf fy: 2008 Enf act date: 01/31/2008 Enf act detail: St Public Notif received Enf act cat: Informal ;r, Enforcement Information: Violation id: 2788108 Orig cd: S wr Enf fy: 2008 Enf act date: 12/28/2007 Enf act detail: St Formal NOV issued Enf act cat: Informal wr Enforcement Information: qur Violation id: 2788108 Orig cd: S Enf fy: 2008 Enf act date: 12/28/2007 "r" Enf act detail: St Public Notif requested Enf act cat: Informal tir Enforcement Information: Violation id: 2788108 Orig cd: S low Enf fy: 2008 Enf act date:410, Enf act detail: St Compliance achieved Enf act cat: Resolving law AtilV Air TC4182090.2s Page A-27 vow law Air °"" GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS vow Enforcement Information: Violation id: 2788005 Orig cd: S vu. Enf fy: 2005 Enf act date: 02/08/2005 Enf act detail: St Public Notif received Enf act cat: Informal vow Enforcement Information: vow Violation id: 2788005 Orig cd: S Enf fy: 2005 Enf act date: 12/28/2004 'war Enf act detail: St Public Notif requested Enf act cat: Informal vow Enforcement Information: Violation id: 2788005 Orig cd: S vow Enf fy: 2005 Enf act date: 12/28/2004 s Enf act detail: St Formal NOV issued Enf act cat: Informal vow Enforcement Information: Violation id: 2788005 Orig cd: S vwv Enf fy: 2005 Enf act date: 07/19/2005 Enf act detail: St Compliance achieved Enf act cat: Resolving °+ur Violations Information: — Violoation id: 2788108 Orig cd: S u. State: VA Viol fy: 2007 Contamcd: 3100 � , Contamnm: Coliform(TCR) Viol code: 22 vow Viol name: MCL,Monthly(TCR) Rule code: 110 vow Rule name: TCR Violmeasur: Not Reported Unitmeasur: Not Reported vow State mcl: Not Reported Cmpbdt: 12/01/2007 Cmpedt: 12/31/2007 our Violations Information: vow Violoation id: 2788005 Orig cd: S State: VA Viol fy: 2004 vow Contamcd: 5000 Contamnm: Lead and Copper Rule Viol code: 52 Viol name: Follow-up Or Routine LCR Tap M/R Rule code: 350 war Rule name: LCR Violmeasur: Not Reported Unitmeasur: Not Reported vrr State mcl: Not Reported Cmpbdt: 10/01/2004 Cmpedt: Not Reported vow PWS ID: VA2003050 — Date Initiated: Not Reported Date Deactivated: Not Reported PWS Name: CROZET AREA C/O RWSA PO BOX 18 vow ALBEMARLE CO.SERVICE AUTHORITY P.O.BOX 1009 vow CHARLOTTESVILLE, VA 22902 Addressee/Facility: System Owner/Responsible Party vow ALBEMARLE CO SERVICE AUTHORITY MR J W BRENT P 0 BOX 1009 low CHARLOTTESVILLE, VA 22902 'ear TC4182090.2s Page A-28 vow .,r %r Al OP I "" GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS V,. Facility Latitude: 38 04 02 Facility Longitude: 078 39 34 City Served: ALBEMARLE 'irr Treatment Class: Treated Population: 3385 Violations information not reported. ow ENFORCEMENT INFORMATION: mar Truedate: 03/31/2009 Pwsid: VA2003050 Pwsname: ACSA CROZET IOW Retpopsrvd: 5948 Pwstypecod: C Air' Vioid: 2788005 Contaminant: LEAD&COPPER RULE Viol.Type: Follow-up and Routine Tap Sampling ,,,,, Complperbe: 10/1/2004 0:00:00 Complperen: 7/19/2005 0:00:00 Enfdate: 12/28/2004 0:00:00 vrr Enf action: State Formal NOV Issued Violmeasur: Not Reported ryrr Truedate: 03/31/2009 Pwsid: VA2003050 — Pwsname: ACSA CROZET Retpopsrvd: 5948 Pwstypecod: C — Vioid: 2788005 Contaminant: LEAD&COPPER RULE Viol.Type: Follow-up and Routine Tap Sampling vow Complperbe: 10/1/2004 0:00:00 Complperen: 7/19/2005 0:00:00 Enfdate: 12/28/2004 0:00:00 Enf action: State Public Notif Requested NN,,, Violmeasur: Not Reported - Truedate: 03/31/2009 Pwsid: VA2003050 Pwsname: ACSA CROZET — Retpopsrvd: 5948 Pwstypecod: C Vioid: 2788005 Contaminant: LEAD&COPPER RULE low Viol.Type: Follow-up and Routine Tap Sampling Complperbe: 10/1/2004 0:00:00 Complperen: 7/19/2005 0:00:00 Enfdate: 2/8/2005 0:00:00 Enf action: State Public Notif Received Air Violmeasur: Not Reported +wr Truedate: 03/31/2009 Pwsid: VA2003050 i,, Pwsname: ACSA CROZET Retpopsrvd: 5948 Pwstypecod: C Air Vioid: 2788005 Contaminant: LEAD&COPPER RULE Viol.Type: Follow-up and Routine Tap Sampling - Complperbe: 10/1/2004 0:00:00 Complperen: 7/19/2005 0:00:00 Enfdate: 7/19/2005 0:00:00 'r' Enf action: State Compliance Achieved Violmeasur: Not Reported vow Truedate: 03/31/2009 Pwsid: VA2003050 mow Pwsname: ACSA CROZET Retpopsrvd: 5948 Pwstypecod: C low Vioid: 2788108 Contaminant: COLIFORM(TCR) tor Viol.Type: MCL,Monthly(TCR) Complperbe: 12/1/2007 0:00:00 .r• Complperen: 12/31/2007 0:00:00 Enfdate: 1/31/2008 0:00:00 Enf action: State Public Notif Received .r Violmeasur: Not Reported low lr Air .rr TC4182090.2s Page A-29 ft. rrr GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS 4..11 Ne„ Truedate: 03/31/2009 Pwsid: VA2003050 Pwsname: ACSA CROZET vrr Retpopsrvd: 5948 Pwstypecod: C Vioid: 2788108 Contaminant: COLIFORM(TCR) *or Viol.Type: MCL,Monthly(TCR) Complperbe: 12/1/2007 0:00:00 ,vis" Complperen: 12/31/2007 0:00:00 Enfdate: 12/28/2007 0:00:00 Enf action: State Formal NOV Issued ASV Violmeasur: Not Reported ver Truedate: 03/31/2009 Pwsid: VA2003050 Pwsname: ACSA CROZET Retpopsrvd: 5948 Pwstypecod: C ,o„ Vioid: 2788108 Contaminant: COLIFORM(TCR) Viol.Type: MCL,Monthly(TCR) vow Complperbe: 12/1/2007 0:00:00 Complperen: 12/31/2007 0:00:00 Enfdate: 12/28/2007 0:00:00 Enf action: State Public Notif Requested Violmeasur: Not Reported low System Name: ACSA CROZET 1111/ Violation Type: Follow-up and Routine Tap Sampling Contaminant: LEAD&COPPER RULE 4111/ Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 ,tioP Violation ID: 2788005 Enforcement Date: 12/28/2004 0:00:00 Enf.Action: State Formal NOV Issued .1111 System Name: ACSA CROZET Violation Type: Follow-up and Routine Tap Sampling Contaminant: LEAD&COPPER RULE Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Violation ID: 2788005 Enforcement Date: 12/28/2004 0:00:00 Enf.Action: State Public Notif Requested System Name: ACSA CROZET — Violation Type: Follow-up and Routine Tap Sampling Contaminant: LEAD&COPPER RULE w Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Violation ID: 2788005 Enforcement Date: 2/8/2005 0:00:00 Enf.Action: State Public Notif Received 4r" System Name: ACSA CROZET Violation Type: Follow-up and Routine Tap Sampling 411► Contaminant: LEAD&COPPER RULE .r Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Violation ID: 2788005 Enforcement Date: 7/19/2005 0:00:00 Enf.Action: State Compliance Achieved NNW System Name: ACSA CROZET — Violation Type: Follow-up and Routine Tap Sampling Contaminant: LEAD&COPPER RULE 411 Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Nor Violation ID: 2788005 Enforcement Date: 12/28/2004 0:00:00 Enf.Action: State Formal NOV Issued Air System Name: ACSA CROZET Violation Type: Follow-up and Routine Tap Sampling Now Contaminant: LEAD&COPPER RULE Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Violation ID: 2788005 Enforcement Date: 12/28/2004 0:00:00 Enf.Action: State Public Notif Requested 4wr 411/ I i' TC4182090.2s Page A-30 Aar 4111/ Mr GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS vow ENFORCEMENT INFORMATION: *Or System Name: ACSA CROZET Violation Type: Follow-up and Routine Tap Sampling A+' Contaminant: LEAD&COPPER RULE Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 `r'" Violation ID: 2788005 Enforcement Date: 2/8/2005 0:00:00 Enf.Action: State Public Notif Received vow System Name: ACSA CROZET — Violation Type: Follow-up and Routine Tap Sampling Contaminant: LEAD&COPPER RULE v""" Compliance Period: 10/1/2004 0:00:00-7/19/2005 0:00:00 Violation ID: 2788005 '- Enforcement Date: 7/19/2005 0:00:00 Enf.Action: State Compliance Achieved Air CONTACT INFORMATION: +w Name: ACSA CROZET Population: 5948 'o" Contact: FERN,GARY Phone: Not Reported +rr Address: 168 Spotnap Road Address 2: CHARLOTTESVILLE vow VA,22 434-9 11r ®r MOW wr vow vow Mwr MAW wr rr+ Al** wrw VOW yr TC4182090.2s Page A-31 xrr mow GEOCHECK®- PHYSICAL SETTING SOURCE MAP FINDINGS RADON vrir vrr AREA RADON INFORMATION err EPA Region 3 Statistical Summary Readings for Zip Code:22901 NOW Number of sites tested:512. Maximum Radon Level:42.1 pCi/L. Minimum Radon Level:0.8 pCi/L. moor pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L ne <4 4-10 10-20 20-50 50-100 >100 "® 350(68.36%) 129(25.20%) 22(4.30%) 11 (2.15%) 0(0.00%) 0(0.00%) gar Federal EPA Radon Zone for ALBEMARLE County: 2 Note:Zone 1 indoor average level>4 pCi/L. :Zone 2 indoor average level>=2 pCi/L and<=4 pCi/L. :Zone 3 indoor average level<2 pCi/L. arr wr err rr lie *Or +rr airy war err Nair +err err *NM w err wr TC4182090.2s Page A-32 r.. r- PHYSICAL SETTING SOURCE RECORDS SEARCHED r TOPOGRAPHIC INFORMATION A.► USGS 7.5'Digital Elevation Model(DEM) Source:United States Geologic Survey 1" EDR acquired the USGS 7.5'Digital Elevation Model in 2002 and updated it in 2006.The 7.5 minute DEM corresponds to the USGS 1:24,000-and 1:25,000-scale topographic quadrangle maps.The DEM provides elevation data "'r with consistent elevation units and projection. Scanned Digital USGS 7.5'Topographic Map(DRG) Source:United States Geologic Survey A digital raster graphic(DRG)is a scanned image of a U.S.Geological Survey topographic map.The map images ler, are made by scanning published paper maps on high-resolution scanners.The raster image is georeferenced and fit to the Universal Transverse Mercator(UTM)projection. Amy mow HYDROLOGIC INFORMATION 'o'" Flood Zone Data: This data,available in select counties across the country,was obtained by EDR in 2003&2011 from the Federal Emergency Management Agency(FEMA). Data depicts 100-year and 500-year flood zones as defined by FEMA. 111 NWI: National Wetlands Inventory. This data,available in select counties across the country,was obtained by EDR .sr in 2002,2005 and 2010 from the U.S.Fish and Wildlife Service. r HYDROGEOLOGIC INFORMATION vor— AQUIFLOWR Information System Source: EDR proprietary database of groundwater flow information 111r EDR has developed the AQUIFLOW Information System(AIS)to provide data on the general direction of groundwater flow at specific points.EDR has reviewed reports submitted to regulatory authorities at select sites and has extracted the date of the report,hydrogeologically determined groundwater flow direction and depth to water table information. 1111, VIIW GEOLOGIC INFORMATION Ayr Geologic Age and Rock Stratigraphic Unit "mow Source:P.G.Schruben, R.E.Arndt and W.J. Bawiec,Geology of the Conterminous U.S.at 1:2,500,000 Scale-A digital representation of the 1974 P.B.King and H.M. Beikman Map,USGS Digital Data Series DDS-11 (1994). low STATSGO: State Soil Geographic Database q1, Source: Department of Agriculture,Natural Resources Conservation Services The U.S. Department of Agriculture's(USDA)Natural Resources Conservation Service(NRCS)leads the national l"` Conservation Soil Survey(NCSS)and is responsible for collecting,storing,maintaining and distributing soil survey information for privately owned lands in the United States.A soil map in a soil survey is a representation — of soil patterns in a landscape.Soil maps for STATSGO are compiled by generalizing more detailed(SSURGO) 11111 soil survey maps. SSURGO:Soil Survey Geographic Database Aar Source: Department of Agriculture,Natural Resources Conservation Services(NRCS) moo Telephone: 800-672-5559 SSURGO is the most detailed level of mapping done by the Natural Resources Conservation Services,mapping No, scales generally range from 1:12,000 to 1:63,360.Field mapping methods using national standards are used to construct the soil maps in the Soil Survey Geographic(SSURGO)database.SSURGO digitizing duplicates the r original soil survey maps.This level of mapping is designed for use by landowners,townships and county natural resource planning and management. Now NOW 111/ 111111 .11r —. TC4182090.2s Page PSGR-1 row Vie PHYSICAL SETTING SOURCE RECORDS SEARCHED ar LOCAL/REGIONAL WATER AGENCY RECORDS FEDERAL WATER WELLS vow PWS: Public Water Systems Source: EPA/Office of Drinking Water Telephone: 202-564-3750 Public Water System data from the Federal Reporting Data System. A PWS is any water system which provides water to at Am" least 25 people for at least 60 days annually. PWSs provide water from wells,rivers and other sources. Air PWS ENF: Public Water Systems Violation and Enforcement Data Source: EPA/Office of Drinking Water Telephone: 202-564-3750 .r Violation and Enforcement data for Public Water Systems from the Safe Drinking Water Information System(SDWIS)after August 1995. Prior to August 1995,the data came from the Federal Reporting Data System(FRDS). +ur USGS Water Wells: USGS National Water Inventory System(NWIS) rrr This database contains descriptive information on sites where the USGS collects or has collected data on surface water and/or groundwater.The groundwater data includes information on wells,springs,and other sources of groundwater. low STATE RECORDS Virginia Public Water Supplies Source: Department of Health,Office of Water Programs NOW Telephone: 804-786-1756 ftrr OTHER STATE DATABASE INFORMATION Virginia Oil and Gas Wells `""' Source: Department of Mines, Minerals and Energy Telephone: 804-692-3200 "'r A listing of oil and gas well locations wr RADON Area Radon Information Source:USGS 4er Telephone: 703-356-4020 The National Radon Database has been developed by the U.S.Environmental Protection Agency +r+ (USEPA)and is a compilation of the EPA/State Residential Radon Survey and the National Residential Radon Survey. The study covers the years 1986-1992.Where necessary data has been supplemented by information collected at private sources such as universities and research institutions. `r" EPA Radon Zones Source: EPA Telephone: 703-356-4020 *NW Sections 307&309 of IRAA directed EPA to list and identify areas of U.S.with the potential for elevated indoor radon levels. mar EPA Region 3 Statistical Summary Readings err Source: Region 3 EPA Telephone: 215-814-2082 wr Radon readings for Delaware,D.C.,Maryland,Pennsylvania,Virginia and West Virginia. OTHER 411r Airport Landing Facilities: Private and public use landing facilities Amy Source: Federal Aviation Administration,800-457-6656 law Epicenters: World earthquake epicenters,Richter 5 or greater ver— Source: Department of Commerce,National Oceanic and Atmospheric Administration VP, Earthquake Fault Lines: The fault lines displayed on EDR's Topographic map are digitized quaternary faultlines,prepared in 1975 by the United State Geological Survey Nov — TC4182090.2s Page PSGR-2 ator PHYSICAL SETTING SOURCE RECORDS SEARCHED STREET AND ADDRESS INFORMATION 41fi, ©2010 Tele Atlas North America, Inc.All rights reserved. This material is proprietary and the subject of copyright protection and other intellectual property rights owned by or licensed to Tele Atlas North America, Inc. The use of this material is subject vow to the terms of a license agreement. You will be held liable for any unauthorized copying or disclosure of this material. wr ASV +ire err %r. "OW `Vr 411110. 11110/ Air *sir' Air A r IOW +ir wrr +irr yr aw. TC4182090.2s Page PSG R-3 mrr ANY NOY AMY Air AMY V/ Mir Appendix D ,., VDH Well Site Approval Letter VOW MEV ..r .r MOW VIP { � t. — %. r"tt. � > y "' COMMONWEALTH of VIRGINIA vow llarissa.1. 1 evine.MI).MPH.LAMA' f)EP-IRTAIENT OP lIE-ti iii 131 Walker Street State Health(om missionet OFFICE OF DRINKING WATER Lexington.VA 24450 Phone:5411-463-7136 John J.Aulhach n.PL Lexington Field Office Fax: 5416 463-35)2 I)treetot.Office of Drinking Water 4111OF September 10. 2014 woo SUBJECT: Albemarle County Water -General Mr. William McKechnie 36 Old Farm Road Alp. Charlottesville. VA 22903 Dear Mr. McKechnie: This letter refers to my August 19, 2013 approval of a \yell site and September 4. 2014 re-inspection of the well site to IMF potentially serve a proposed waterworks in Albemarle County. Virginia. In accordance with §12VAC5-590-280 of the ..r Commonwealth of Virginia Waterworks Regulations, the proposed well site is tentatively approved by this Department for the construction of a well to be utilized as a public drinking water supply, subject to the following conditions: ------------------------------- ------------ --- --- --- Proposed Well Site No. 1 *SW City/County: Albemarle County Latitude: N 38.06217° Location: — — --- — �,, Longitude: -- W 78.64859°-- - ---------------------- Marked: Unmarked, adjacent to existing well of unknown construction. See attached. Well Construction Class: Class II B(Minimum 50 feet of casing and grouting). Approval Expiration Date: September 9,2015. if drilling of the well has not commenced by this date, re-inspection of the well site will be required. Shall he sited minimum of 10 feet from building foundation and minimum 10 feet from US 4Now— Route 250. Minimum distance of 50 feet between the well and all potential sources of contamination. The well lot must he graded as necessary to divert surface run-off from the well and to prevent ponding on the well lot. Well Lot Characteristics: -----_.___--_ -----___-, — The well lot must be served by an all-weather access road. The entirety of the \ell lot must be located higher than the 100-year flood elevation. Use cement mortar grout 14ith a maximum 6% hentonite, in accordance with IVulerworks Grouting: Regulations. Notify this office of the date and time that the well will he grouted. Provide this go" information as soon as possible so that a member of our staff may be present during_grouting.- -- — VIRGINIA Now v, DHOF HEALTH NT Protecting You and Your Environment WWW.VDH.VIRGINIA.GOV View Mr. William McKechnie .., Page 2 of 3 SUBJECT: Albemarle County Air Water--General wow %Sr A yield and drawdown test must be run for at least 18 hours. We recommend the pumping rate be controlled throughout the test to maximize the production from the well and to produce a Yield and Drawdown Test stabilized pump water level for at least the last six hours of the yield test. Immediately following Duration: the yield and drawdown test the water level recovery in the well should be recorded for no less ®, than 6 hours or until the well returns to its static water level, whichever occurs first. If water will discharge into streams during pumping tests, please contact the Department of Environmental Quality Northern Regional Office to determine if a discharge permit is required. A series of twenty bacteriological samples must be collected from the well discharge and submitted to a certified laboratory (DCLS or private laboratory) in order to determine the bacteriological quality of the raw groundwater. One bacteriological sample must be collected every 30 minutes or more during the last part of the pump test. These samples must be analyzed — by the total coliform and E. coli Most Probable Number(MPN)test method. Maw Required Bacteriological -- and Chemical Sampling: Water samples must he collected to analyze for cyanide. nitrates/nitrites, inorganic chemicals, ... metals, radiological, and volatile organic chemicals. The chemical samples should be collected =or near the end of the pump test, prior to the recovery period. viw The wellhead area does not appear to be vulnerable to synthetic organic chemicals(SOCs). You will not be required to take developmental samples for SOCs. vo. Well Completion Report(G W2). w.. Well yield and drawdown test results. — — Results of required bacteriological and chemical sampling. Submittals Required Prior Preliminary engineering report. to Issuance of - IOW Construction Permit: Construction permit application(for completion of the well installation/waterworks). Final construction plans and specifications prepared by a professional engineer licensed in Virginia, including recorded plat of the well lot, and a recorded dedication document for the well lot. The dedication document shall clearly state that the well lot will be used only for the rw. waterworks appurtenances as long as the lot is being used as part of the waterworks. 'Air Upon receipt of the required documentation and after plans and specifications have been approved, a construction permit or permits will be issued by the State Health Commissioner in accordance with § 12VAC5-590-230 of the Waterworks Regulations. Construction of the waterworks facilities shall not be started until the construction permit has been issued. Air All water well drillers are required to be licensed by the State Board for Contractors. You may contact the State Board for Contractors, Virginia Department of Professional and Occupational Regulation, 9960 Mayland Drive, Suite 400, Richmond, VA 23233 (804/367-8511)to determine if a well driller is licensed. AISW • Mr. William McKechnie Page 3 of 3 SUBJECT: Albemarle County Am. Water-General If you have any questions. please contact me at 540-463-0424. Amy AO, Sincerely, 111/ (,(e_ Steven J. Kvech, P.E. District Engineer SJK/kl/1409w 5 1" Enclosures cc/w End VDH -ODW- Richmond Central Mr. Todd A. Beach, DEQ OSGWSP/Groundwater Characterization Agy cc Albemarle County Executive, Mr.Thomas Foley Albemarle County Health Department-Attn: Dr. Charles Devine. MD. MPH mow Now wrr .r VOW MOW t.. NOW r.. IOW NOW %NO ; 1111110. • ,,,,, ,,,f.. ..,,,,,,,t-Y.',-,, „, 1.;),..:41,11 j‘,,,4.4(1::4:il'`'.1 k:' •';'..4'''' ''' ' * IV lb, ,,.....:,..,,,, „ ,, .44 a .-pct., 14- A 4.,,.., .- ti: ', .t.ts.. 1,-`4.. . - ., %,'i,,-,:;., ,';,t-,■:.:,-,..,,,,-,:: , -'--'..":-.:=..t-.. -iet` Vs,ft,)a- 1-4 •,,,9 II( . nik4,itiv i''''' -...„%f:0.-r,:" ,'„,"._k, %NO „' "1?t; , Ci• '4.'i;.-..:i'2.'1* 1 .;1, ' it 1,e-A''ft !*.* "1:3 ,..,.1-,..,. '-'.. -,:',.,-:,4,;:, (I) (I) (1) , %10# 4 * ,„.. -ir,v...., #•',,..,y, ,- N eel* - , L_ '' t41910#4*.e,i'Z a t*'1641° ,fo, ;=.:7, ,''.,-,t:'...„511,6?:, Fr *l'‘.: 1/4**.--- .777*41-•-) 0 0 ^:,;:,;;:"-•'..7.;`,P..1;',:,i;',`'..11' 'l'at' • t-1, ' 1:.''Z'S '(-) -0 4--' Vet ,c#i;..sr , .--- - -,-,,,,,, ...i:‘,. k.F-,Iti . ri:,'',-;,k,),,.. ..g (3 Q),, ,...,..,:,..L::,;;;;;. ,4,e,:lA '"%. .v,'. ,u.,:"* ei.i . --,, ....-- e .i' 1-7 . M . ".` .1.:-....■ ,.. -1- - ,j'''' b.0 CY-ttif.:i_.;,-:-;'4A.:• tlif . k:.,egvit.,:i. i,,,,t,;', , ..6 . . - hi 4.) 14 4) _el... ' I*.' 4-5 a, ID •;7 C.:.;k1?..,:;',!(;',:i',',,;, ,t;::i 41*.x'.`•14'0,,, — ki.„__h.'s' k 0 4%,„:4, it, - . •'',..e -. ,-, (7) ',,,,,,:kt:414-4:?„,-t..4= U-I , CO ,',-,l'f,,,•::',:,,-.4. IF;i4 jukltitf:'''.4:4,04 ',... -.. 2-.V,I, ' ,,,..--i4i.4 2, -•.,,,,,,,, ,,;,:'`,..,i'v..',.,';',', %so . •,,t.--.... ,.,....„ ;.,..., 11`4.,„ NI.. .441, -1.",/t...z. ..1 iiii7,, '',„,. o'„L' . ' .=•-:',.'!.'.,L- ' ...,',,--t's ,,,:-3.--,„,, -,.."4„4„:AL , .,_., ., er , .S'i" ,"•-•,f, -i.,. ,L,-,-:,--:,,,- i-- 4 .4(,,*■), ' ,-1' %4,4:112,i51 I '`-..,•,;:;,:i'',,:.7,4''''',;,,,t,.! ,P., ,, '""' 0,4:s• t ,.:-V;',,tt,-t,,t'-`,*, . i till° 1110. ii,... 10 ''ICttft! .W 4 3/4,.....'cr "i \ ' ' '.: 2 -4 :,4,r5 .4,:vaz.%,,,,,aiww.,:•.":30•4er,44,4,..,4",...?,1.;,r,,;::,,,, ' ''',,*^..`• '''iri'',•'- C) 1 Igo -r:,,A.,:i At.t:'''' 1;**•:,4 t: '1 t 1,,,,I. rift - . , :At. . :44 r-.1:„..c..,-.". •-....q■ z•-•:‘. czt- -Alt'-'• .• .4 0...-b: - ... \ a ' ., ,,, -'.••; .4,,,444.-..:2-4' ,, , ,.•.;.,' 4,7'....*4.',.:,,::,- ,-.1 ..f,...:44 .,. -:.!,t„,.1!",,‘,-;.4(''''\'‘ a ' \ i 1 , ' `' f'. .',,,IP...•a• 7, (.1.) , 4i0 ak-f•41. t i. • ' ,..)7,::. ,,"144".:••::: -I-) , , ,J,-9 r .p*, .,,, ' c: • ,A, .14:-S,V, 1 ' ' '',47::5,2....;.:41`., CC i 4111110 -'40 .,14i0i,. .. ',..- ,..;i.,-• ,- ...,: t,'' ;•!.• \:,•,es4.. ' - -1.341-i?T*1. '^'' C <44 ;:toirle. .e 4..t...4,4;" i.- al.:if. ‘4.'4. 5:/,' -4..414. 41 ,..•,,,„z...:,,,,,,,,,.4„,,;1••:-..., 0 i '60 . . . .i,,,,,,,t-,,tt..t, . , . • . 0 .. . t --V, .- ,:";-,,t-. ,:-ti,W;Lt--, C,:r.v..- , 4 , I. ';;-',.., '-7"?,.3.•,'Zrf:,:t'f . ': 7" . „, _ (-) i 410 ,-„ i'is l'i; t.,; ''''f ttkk- --(1) ''''°-''',. ''ti•'1, 0 ,h10 ' e, .'.' ,, l'.7 :'1.: .;:-•,‘•-f.- .74...-- 4',.. t. ...-- , ..0 ..,...:-.. ..„. ' ., . .. • .• 1,. , i -').,:--. 4 --.'"L.N.I.: --- 4-- 0 4110 3i*.;: •, , ,,,,ii =_ '..1 :. -' •,•,1.--k-; . .. ...„. It. *, ,4 If• ...,1 ..6; ix.,„.,14N.' Q1 41110 , r, ,',0- , :•I''. 4 't:1416•.L. ;t (j) $ r r.- --,.'1, ■.... ts,„ -, - ..--: .,;„.; t v) '•./ 1:'.. "e•••••1,;.,, .— 410 "...:- s ::”" •N •- '4%.i.,?- . . i f,l• ', 77 kg - .: 4--, • ... , t ',,, ., a. — ., g• i ti':C.!.. ', A ::' -- Y,1 Z,",,,$''. ;Al' Q.) 4110 '141 .t" '. '." • 1..... . ., te CU -..•„3.1.;k. -I—+ ...ir.' ' ••• ..'''.;',_ii,/' i • • , f s' PL' 17' V) AL II. ' Ill ,;.4 , ,544.• bp 460 "•, ' 4 zz .i.1: , ,,,t.- ,.. - , - t: ,', :0 o cu ,,.:,• -04,--..j , 1.4. .. , e..,,,.`..,..4:4 r ..• 41 ... . . .t.cot!...of3.-. . ck._ v, ,,,,,.1 t,„.•41„..,,,,,,t7.' (...9 iii -7'' . ..- . lc -otiV , if , ,,„.„,..., ..4.1,,,,a,01;,--_.: , ,,, .4•,;:fgW - ....st_41,..1$1. , . 410 1 , il w c* '-'• le c ,. 46." . 4 :.-- -•-• Ii- * :'-lt. sii:ii:.,...). 1‘.,17. '' ' . 1 itt, ' 46 ki..... r1111/ Appendix E Soil Analytical Report INW IOW r.. VA TestAmerica THE LEADER IN ENVIRONMENTAL TESTING ANALYTICAL REPORT TestAmerica Laboratories, Inc. TestAmerica Pittsburgh 301 Alpha Drive RIDC Park Pittsburgh, PA 15238 Tel: (412)963-7058 '" . _ TestAmerica Job ID: 180-23737-1 ... Client Project/Site: Mechum's Trestle For William McKechnie 36 Old Farm Road Charlottesville, Virginia 22903 Attn: William McKechnie 4/7e, g r•► Authorized for release by: 8/14/2013 3:11:29 PM Ryan Hall, Customer Service Manager kr ryan.hall @testamericainc.com kir `r. LINKS Review your project �.. results through ' Total Access Have a Question? As k— /The This report has been electronically signed and authorized by the signatory.Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature. E __a=- Results relate only to the items tested and the sample(s)as received by the laboratory. Visit us at: 4111. www.testamericainc.com 41111. vow Client:William McKechnie TestAmerica Job ID: 180-23737-1 Project/Site: Mechum's Trestle Table of Contents Cover Page 1 Table of Contents 2 Case Narrative 3 Definitions/Glossary 4 �.. Certification Summary 5 Sample Summary 6 Method Summary 7 Lab Chronicle 8 Client Sample Results 9 QC Sample Results 10 QC Association Summary 12 Chain of Custody 13 Receipt Checklists 15 ANY API TestAmerica Pittsburgh Page 2 of 15 8/14/2013 Case Narrative Client:William McKechnie TestAmerica Job ID: 180-23737-1 "° Project/Site: Mechum's Trestle NW' 211 Job ID: 180-23737-1 Laboratory:TestAmerica Pittsburgh Aar Narrative view Job Narrative +11r 180-23737-1 tow Comments r, No additional comments. err Receipt The samples were received on 8/1/2013 8:50 AM;the samples arrived in good condition,properly preserved and,where required,on ice. `ir The temperature of the cooler at receipt was 5.7°C. rrr GC VOA ' No analytical or quality issues were noted. `r", GC Semi VOA No analytical or quality issues were noted. wr General Chemistry No analytical or quality issues were noted. AMY Organic Prep No analytical or quality issues were noted. r +air vrr VOW +rr Orr +r w *OW IOW 4111111, MAW air TestAmerica Pittsburgh Page 3 of 15 8/14/2013 Definitions/Glossary Client:William McKechnie TestAmerica Job ID: 180-23737-1 '" Project/Site: Mechum's Trestle Glossary AUW Abbreviation These commonly used abbreviations may or may not be present in this report. 4 wr a Listed under the"D"column to designate that the result is reported on a dry weight basis �r %R Percent Recovery CNF Contains no Free Liquid Nov DER Duplicate error ratio(normalized absolute difference) 411■9 DL,RA,RE,IN Indicates a Dilution,Re-analysis,Re-extraction,or additional Initial metals/anion analysis of the sample DLC Decision level concentration 'eir MDA Minimum detectable activity EDL Estimated Detection Limit wow MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level(Dioxin) NC Not Calculated also ND Not detected at the reporting limit(or MDL or EDL if shown) PQL Practical Quantitation Limit *sr QC Quality Control Air RER Relative error ratio RL Reporting Limit or Requested Limit(Radiochemistry) low RPD Relative Percent Difference,a measure of the relative difference between two points TEF Toxicity Equivalent Factor(Dioxin) wry TEQ Toxicity Equivalent Quotient(Dioxin) Amw Nov v�r .rw virr VOW *or ar VOW NNW Mir Aar Orr wr `vrr+ .,.., TestAmerica Pittsburgh .r. Page 4 of 15 8/14/2013 Mir Vale 941 Certification Summary Client:William McKechnie TestAmerica Job ID: 180-23737-1 '111/M, Project/Site: Mechum's Trestle 'W Laboratory: TestAmerica Pittsburgh °..' All certifications help by this laboratory ale listed Not all certtfications are applicable to this report °'el'' Authority Program EPA Region Certification ID Expiration Date Arkansas DEQ State Program 6 88-0690 06-27-14 moor California NELAP 9 4224CA 03-31-14 10 mis. Connecticut State Program 1 PH-0688 09-30-14 Florida NELAP 4 E871008 06-30-14 Illinois NELAP 5 002602 06-30-14* ,N, Kansas NELAP 7 E-10350 01-31-14 L-A-8 DoD ELAP L2314 07-16-16 l'' Louisiana NELAP 6 04041 06-30-13* New Hampshire NELAP 1 203011 04-05-14 mow New Jersey NELAP 2 PA005 06-30-14 Vtrr New York NELAP 2 11182 04-01-14 North Carolina DENR State Program 4 434 12-31-13 Nler Pennsylvania NELAP 3 02-00416 04-30-14 VW South Carolina State Program 4 89014 04-30-13* US Fish&Wildlife Federal LE94312A-1 11-30-14 vow USDA Federal P-Soil-01 04-16-15 +rr USDA Federal P330-10-00139 05-23-16* Utah NELAP 8 STLP 04-30-14 °'r' Virginia NELAP 3 460189 09-14-13 West Virginia DEP State Program 3 142 01-31-14 Air Wisconsin State Program 5 998027800 08-31-13* Alir VW AI., NW NNW err VW liar IOW +ter ANY ilr 'sir. *Expired certification is currently pending renewal and is considered valid. mow TestAmerica Pittsburgh vrr Page 5 of 15 8/14/2013 ANY .r NNW Sample Summary Client:William McKechnie TestAmerica Job ID: 180-23737-1 INV Project/Site: Mechum's Trestle Nap Lab Sample ID Client Sample ID Matrix Collected Received 180-23737-1 SITE'A' Solid 07/31/1315'10 08/01/13 08:50 mar 180-23737-2 SITE'B' Sol id 07/31/13 15 10 08/01/13 08.50 w ror r 6 +rrr VIM INV MOW ftr ANY vr. 1111r +1r/ IOW IOW Barr Afar arnr 11111, TestAmerica Pittsburgh Page 6 of 15 8/14/2013 Ater Method Summary Client:William McKechnie TestAmerica Job ID: 180-23737-1 Project/Site: Mechum's Trestle Nur "o" Method Method Description Protocol Laboratory 8081A Organochlorine Pesticides(GC) SW846 TAL PIT 8141A Organophosphorous Pesticides(GC) SW846 TAL PIT err 2540G SM 2540G SM22 TAL PIT vow Protocol References: crrr SM22=SM22 SW846="Test Methods For Evaluating Solid Waste,Physical/Chemical Methods",Third Edition,November 1986 And Its Updates. Laboratory References: TAL PIT=TestAmerica Pittsburgh,301 Alpha Drive,RIDC Park,Pittsburgh,PA 15238,TEL(412)963-7058 mow w° IOW IOW +erg ,rr err yr rr VOW +r =ar► Nur Vr wrr *Yr w® Air arrr *sr WNW '1rr Y+r• TestAmerica Pittsburgh ®rr Page 7 of 15 8/14/2013 *NW INV ler Lab Chronicle Client:William McKechnie TestAmerica Job ID: 180-23737-1 maw Project/Site: Mechum's Trestle .r ,III• Client Sample ID: SITE 'A' Lab Sample ID: 180-23737-1 Date Collected: 07/31/13 15:10 Matrix:Solid — Date Received: 08/01/13 08:50 Percent Solids:92.1 `r Batch Batch Dil Initial Final Batch Prepared Prep Type Type Method Run Factor Amount Amount Number or Analyzed Analyst Lab - - ire Total/NA Prep 3541 15.1 g 20.0 mL 79412 08/03/13 05:20 KLG TAL PIT it Total/NA Analysis 8081A 1 80149 08/09/13 17:23 DFE TAL PIT Instrument ID: GC15 Now Total/NA Prep 3541 15 0 g 2 5 mL 80016 08/09/13 06:10 KLG TAL PIT lit. Total/NA Analysis 8141A 1 80207 08/10/13 14 16 DFE TAL PIT 8 41W Instrument ID: GC5 +orr Total/NA Analysis 2540G 1 79230 08/01/13 15:28 PGJ TAL PIT Instrument ID: NOEQUIP VW NOW Client Sample ID: SITE 'B' Lab Sample ID: 180-23737-2 .r Date Collected:07/31/13 15:10 Matrix:Solid Date Received: 08/01/13 08:50 Percent Solids: 93.2 Batch Batch Dil Initial Final Batch Prepared l r Prep Type Type Method Run Factor Amount Amount Number or Analyzed Analyst Lab Total/NA Analysis 8081A 1 80149 08/09/13 18:10 DFE TAL PIT liar Instrument ID: GC15 ®r Total/NA Prep 3541 15.1 g 20.0 mL 79412 08/03/13 05:20 KLG TAL PIT Total/NA Prep 3541 15.0 g 2.5 mL 80016 08/09/13 06 10 KLG TAL PIT vier Total/NA Analysis 8141A 1 80207 08/10/13 15:41 DFE TAL PIT l'' Instrument ID: GC5 Total/NA Analysis 2540G 1 79230 08/01/13 15:28 PGJ TAL PIT Instrument ID. NOEQUIP wir +rr Laboratory References: TAL PIT=TestAmerica Pittsburgh,301 Alpha Drive,RIDC Park,Pittsburgh,PA 15238,TEL(412)963-7058 vow Analyst References: +rr Lab:TAL PIT Air Batch Type:Prep KLG=Kevin Geehring AN, Batch Type'Analysis DFE=David Eppinger PP er 9 "ow PGJ=Paul Johnson VW VW AMY MOW IN/ +r *NW TestAmerica Pittsburgh Page 8 of 15 8/14/2013 war ...r Client Sample Results Client:William McKechnie TestAmerica Job ID: 180-23737-1 'W, Project/Site: Mechum's Trestle lay Client Sample ID: SITE 'A' Lab Sample ID: 180-23737-1 "o' Date Collected:07/31/13 15:10 Matrix:Solid ,� Date Received: 08/01/13 08:50 Percent Solids:92.1 VIP' Method:8081A-Organochlorine Pesticides(GC) . Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac yaw Chlordane(technical) ND 18 0.79 ug/Kg 08/03/13 05:20 08/09/13 17:23 1 "aw Surrogate %Recovery Qualifier Limits Prepared Analyzed Dil Fac DCB Decachlorobiphenyl(Surr) 66 45.130 08/03/13 05:20 08/09/13 17:23 1 Avir DCB Decachlorobiphenyl(Surr) 66 45.130 08/03/13 0520 08/09/13 1723 1 'w" Tetrachloro-m-xylene 75 45.130 08/03/13 05:20 08/09/13 17:23 1 Tetrachloro-m-xylene 73 45.130 08/03/13 05.20 08/09/13 17:23 1 : Method:8141A-Organophosphorous Pesticides(GC) 9 Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac — Chlorpyrifos ND 36 3.5 ug/Kg 08/09/13 06'10 08/10/13 14:16 1 Surrogate %Recovery Qualifier Limits Prepared Analyzed Dil Fac row Triphenylphosphate 72 55_125 08/09/13 06:10 08/10/13 14:16 1 Tributyl phosphate 65 47.130 08/09/13 06:10 08/10/13 1416 1 aar General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac low Percent Moisture 7.9 0.10 0 10 % 08/01/13 15:28 1 Percent Solids 92 0.10 0.10 % 08/01/13 15:28 1 war Client Sample ID: SITE 'B' Lab Sample ID: 180-23737-2 Date Collected:07/31/13 15:10 Matrix: Solid iiir Date Received: 08/01/13 08:50 Percent Solids: 93.2 `er Method:8081A-Organochlorine Pesticides(GC) Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Are Chlordane(technical) ND 18 0.78 ug/Kg 08/03/13 05:20 08/09/13 18 10 1 'a1✓ Surrogate %Recovery Qualifier Limits Prepared Analyzed Dil Fac Air DCB Decachlorobiphenyl(Surr) 73 45.130 08/03/13 05:20 08/09/13 18:10 1 DCB Decachlorobiphenyl(Surr) 72 45.130 08/03/13 05:20 08/09/13 18:10 1 Ator Tetrachloro-m-xylene 82 45.130 08/03/13 05:20 08/09/13 18:10 1 Air Tetrachloro-m-xylene 80 45.130 08/03/13 05:20 08/09/13 18:10 1 "r" Method:8141A-Organophosphorous Pesticides(GC) Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Chlorpyrifos ND 35 3 5 ug/Kg 08/09/13 06 10 08/10/13 15:41 1 Ver Surrogate %Recovery Qualifier Limits Prepared Analyzed Dil Fac "ew Tnphenylphosphate 84 55.125 08/09/13 0610 08/10/13 15.41 1 Tributyl phosphate 84 47.130 08/09/13 06:10 08/10/13 15:41 1 Air Air General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac `ow Percent Moisture 6.8 0 10 0.10 % 08/01/13 15:28 1 Percent Solids 93 0.10 0.10 % 08/01/13 15.28 1 mow `oar Aran war Aloe TestAmerica Pittsburgh 'aw Page 9 of 15 8/14/2013 lr QC Sample Results Client:William McKechnie TestAmerica Job ID: 180-23737-1 "` Project/Site: Mechum's Trestle liew Method: 8081A - Organochlorine Pesticides (GC) Now ,r, Lab Sample ID:MB 180-79412/1-A Client Sample ID:Method Blank Matrix:Solid Prep Type:Total/NA 's"' Analysis Batch:80149 Prep Batch:79412 MB MB vow Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac ,., Chlordane(technical) ND 17 0.73 ug/Kg 08/03/13 05:20 08/09/13 18:25 1 MB MB Surrogate %Recovery Qualifier Limits Prepared Analyzed Oil Fac 'ito DCB Decachlorobiphenyl(Surr) 85 45.130 08/03/13 05:20 08/09/13 18:25 1 us, DCB Decachlorobiphenyl(Surr) 84 45.130 08/03/13 05:20 08/09/13 18:25 1 Tetrachloro-m-xylene 102 45.130 08/03/13 05:20 08/09/13 18:25 1 `ems' Tetrachloro-m-xylene 100 45.130 08/03/13 05:20 08/09/13 18.25 1 a'" Lab Sample ID:LCS 180-79412/2-A Client Sample ID:Lab Control Sample 10 "i„ Matrix:Solid Prep Type:Total/NA Analysis Batch:80149 Prep Batch:79412 Air LCS LCS vow Surrogate %Recovery Qualifier Limits DCB Decachlorobiphenyl(Surr) 89 45.130 low DCB Decachlorobiphenyl(Surr) 88 45.130 ', Tetrachloro-m-xylene 105 45.130 Tetrachloro-m-xylene 102 45.130 *r Lab Sample ID: 180-23737-1 MS Client Sample ID:SITE'A' Alw Matrix:Solid Prep Type:Total/NA low Analysis Batch:80149 Prep Batch:79412 'Iry MS MS Surrogate %Recovery Qualifier Limits jrr► DCB Decachlorobiphenyl(Surr) 72 45.130 DCB Decachlorobiphenyl(Surr) 71 45.130 uw Tetrachloro-m-xylene 79 45.130 r Tetrachloro-m-xylene 78 45.130 Lab Sample ID: 180-23737-1 MSD Client Sample ID:SITE'A' «lir Matrix:Solid Prep Type:Total/NA Analysis Batch:80149 Prep Batch:79412 wr+ MSD MSD "NW Surrogate %Recovery Qualifier Limits DCB Decachlorobiphenyl(Surr) 78 45.130 uw DCB Decachlorobiphenyl(Surr) 78 45.130 W.. Tetrachloro-m-xylene 88 45_130 Tetrachloro-m-xylene 85 45_130 uwo uuso Method: 8141A -Organophosphorous Pesticides (GC) law Lab Sample ID:MB 180-80016/1-A Client Sample ID:Method Blank low Matrix:Solid Prep Type:Total/NA Analysis Batch:80207 Prep Batch:80016 *sr MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Chlorpyrifos ND 33 3.2 ug/Kg 08/09/13 06'10 08/10/13 16:10 1 Air yr. TestAmerica Pittsburgh 1.. Page 10 of 15 8/14/2013 vier ler vile ,,. QC Sample Results Client:William McKechnie TestAmerica Job ID: 180-23737-1 *err Project/Site: Mechum's Trestle VW Method: 8141A - Organophosphorous Pesticides (GC) (Continued) wr Lab Sample ID: MB 180-80016/1-A Client Sample ID:Method Blank Matrix:Solid Prep Type:Total/NA I„r Analysis Batch:80207 Prep Batch:80016 MB MB lir Surrogate %Recovery Qualifier Limits Prepared Analyzed DR Fac vow Triphenylphosphate 86 55.125 08/09/13 06:10 08/10/13 16:10 1 Tributyl phosphate 76 47.130 08/09/13 06:10 08/10/13 1610 1 Air 111110' Lab Sample ID: LCS 180-80016/2-A Client Sample ID: Lab Control Sample Matrix:Solid Prep Type:Total/NA 1110' Analysis Batch:80207 Prep Batch:80016 Spike LCS LCS %Rec. low Analyte Added Result Qualifier Unit D %Rec Limits ww Chlorpyrifos 333 323 ug/Kg 97 50.130 ' 0__ vow LCS LCS Surrogate %Recovery Qualifier Limits +rr Triphenylphosphate 97 55.125 Tributyl phosphate 98 47.130 Imr mar Lab Sample ID: 180-23737-1 MS Client Sample ID:SITE'A' Matrix:Solid Prep Type:Total/NA .41. Analysis Batch:80207 Prep Batch:80016 l Sample Sample Spike MS MS %Rec. Analyte Result Qualifier Added Result Qualifier Unit D %Rec Limits le r Chlorpyrifos ND 362 318 ug/Kg 88 50_130 low MS MS Surrogate %Recovery Qualifier Limits low Triphenylphosphate 73 55.125 +®r Tributyl phosphate 68 47.130 `°r Lab Sample ID: 180-23737-1 MSD Client Sample ID:SITE'A' Matrix:Solid Prep Type:Total/NA VW Analysis Batch:80207 Prep Batch:80016 war Sample Sample Spike MSD MSD %Rec. RPD Analyte Result Qualifier Added Result Qualifier Unit D %Rec Limits RPD Limit wr Chlorpyrifos ND 359 278 ug/Kg 77 50_130 13 25 -- MSD MSD wr Surrogate %Recovery Qualifier Limits Triphenylphosphate 76 55.125 'aw Tributyl phosphate 78 47.130 mmw rrr low mow 110` wr ... TestAmerica Pittsburgh 'ow Page 11 of 15 8/14/2013 Vyr `ar VW iar QC Association Summary Client:William McKechnie TestAmerica Job ID: 180-23737-1 NIP' Project/Site: Mechum's Trestle Aier GC Semi VOA Prep Batch:79412 vow Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch ... `OW 180-23737-1 SITE'A' Total/NA Solid 3541 180-23737-1 MS SITE'A' Total/NA Solid 3541 Ire 180-23737-1 MSD SITE'A' Total/NA Solid 3541 ./ 180-23737-2 SITE'B' Total/NA Solid 3541 LCS 180-79412/2-A Lab Control Sample Total/NA Solid 3541 low MB 180-79412/1-A Method Blank Total/NA Solid 3541 .ir Prep Batch:80016 ler Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch low 180-23737-1 SITE'A' Total/NA Solid 3541 180-23737-1 MS SITE'A' Total/NA Solid 3541 VIIII 180-23737-1 MSD SITE'A' Total/NA Solid 3541 180-23737-2 SITE'B' Total/NA Solid 3541 law LCS 180-80016/2-A Lab Control Sample Total/NA Solid 3541 yr MB 180-80016/1-A Method Blank Total/NA Solid 3541 Alw Analysis Batch:80149 41.0 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 180-23737-1 SITE'A' Total/NA Solid 8081A 79412 *MP 180-23737-1 MS SITE'A' Total/NA Solid 8081A 79412 or 180-23737-1 MSD SITE'A' Total/NA Solid 8081A 79412 180-23737-2 SITE'B' Total/NA Solid 8081A 79412 Amor LCS 180-79412/2-A Lab Control Sample Total/NA Solid 8081A 79412 MB 180-79412/1-A Method Blank Total/NA Solid 8081A 79412 Analysis Batch:80207 Ayr Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch err+ 180-23737-1 SITE'A' Total/NA Solid 8141A 80016 ,W, 180-23737-1 MS SITE'A' Total/NA Solid 8141A 80016 180-23737-1 MSD SITE'A' Total/NA Solid 8141A 80016 All le 180-23737-2 SITE'B' Total/NA Solid 8141A 80016 LCS 180-80016/2-A Lab Control Sample Total/NA Solid 8141A 80016 mew MB 180-80016/1-A Method Blank Total/NA Solid 8141A 80016 awe As General Chemistry vasw Analysis Batch:79230 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 180-23737-1 SITE'A' Total/NA Solid 2540G low 180-23737-2 SITE'B' Total/NA Solid 2540G mow 'ar wrr VIIIIIP .r. TestAmerica Pittsburgh Page 12 of 15 8/14/2013 Air NNW `wr VW r N C e e c ,CI w o I vow II ix, 0 0 z x z L c...IT\ Pi ANY a / y U to lc" ' _ b 3 a m p e V%-. . g ,:. , r, �' �� P a_ `Y n pe a, to p f° 0. °u i0 0 2> vi ‘■ -1 4* N i ,ftor 9 0 9 A ff. J .0 g P - i �, y ti ul w s I• !2 --- g '$ ,94 W E -r• 1 1 i I rW: ,' 2 e C _ 1 q F j Air d d x S J rtrr JAqueous il {Sediment *err, N. —'4.,,,,. to N. j X. X Solid ;,Itl t n �._ Other, ( II trr4 =W E. i y m V 1 ([ m I 1 II2SO4 e — 0, T i . ,. ,_.3. . g ll 0 I. � �a � ,NaOH — _ yMy i i ZnAcl "' ," �. N — N __ a ,4' - 1 NaO11 ,� N�' 4 °E ; O \ 6c r( .2%.....111.* I IInpres 0+ a T. 0r `i1� 5' Oilier: ` 0 `g'o ,. i g w 1 ig g Al , i r7 0 o.+ j' e. I .a & 0..- i __. i .10,, o -- —I i H m _sJ V't n A 'yam �; a o a. Q � � ..�n it i 3 FYI► d X11. I:431 E Q vr\ Page 13 of 15 8/14/2013 VIIV 1 I •,y L O1 'VW a CO . rm . G „H rAk 0" � 'i. ' �. q ptt.4,0 1 E � R =,u. a „ i rY_ � LP j _ low . �.1- --.-rim N C dY },Y A' y i. 41111r U.1 .� ''..*,.,e 4, .. $ ,, „,, I- ,' =l'.A'6• awry. -- ,. 4,,• [5-.�� , l7 e q' Zi 7 , . Eill - -- . 3 �_ T.,__-.._-----' 't:' w p m ' 0 VII• "'i-". "."-----•■■■ Ots‘ * 0$14-6--ilir)::. 7...1 W -.4--------- IZ„ * ...---e--.....,... I lc,t.:2 , sv tD al : .................... 92 :910Sisopiwi IP 1, 11111111 Glii) � ' . I 0.0..............,.......os•,..;.•'....,'...‘.....''...../e1 0....'. ....... ......... ipig__, .k 13 . ....------ . • F , "o . I. , SW --j— , ,,ray (C�'y ' `7TZO 3 brr _ _ ------ '■ it -'0`q -- -go --, --=;- --— — ,- --- - -- --- __ _ j ` 5 t VII NW, SOW Page 14 of 15 8/14/2013 ,,o. Login Sample Receipt Checklist NW +r. Client:William McKechnie Job Number: 180-23737-1 +r. Login Number:23737 List Source:TestAmerica Pittsburgh List Number:1 Creator:Wattras,Jonathan 4111r Question Answer Comment vow Radioactivity wasn't checked or is<1=background as measured by a survey N/A meter. The cooler's custody seal,if present,is intact. True law Sample custody seals,if present,are intact. True • The cooler or samples do not appear to have been compromised or True tampered with. wr Samples were received on ice. True —,11110 Cooler Temperature is acceptable. True Cooler Temperature is recorded. True tow COC is present. True Asir COC is filled out in ink and legible. True +w►' COC is filled out with all pertinent information. True Is the Field Sampler's name present on COC? True There are no discrepancies between the containers received and the COC. True %ft. Samples are received within Holding Time. True Sample containers have legible labels. True Containers are not broken or leaking. True Sample collection date/times are provided. True law Appropriate sample containers are used. True O Sample bottles are completely filled. True Sample Preservation Verified. True viirt There is sufficient vol.for all requested analyses,incl.any requested True • MS/MSDs wrr Containers requiring zero headspace have no headspace or bubble is True <6mm(1/4"). low Multiphasic samples are not present. N/A Samples do not require splitting or compositing. N/A VOW Residual Chlorine Checked. N/A w✓ .411W 41111/ ewr wwr MOW NINW TestAmerica Pittsburgh Page 15 of 15 8/14/2013 1111, VOW MEW VIP" IMF NM' Appendix F References VIW lir MIW w w. VaI Tier 3 Groundwater Assessment- Alechum's Trestle, LLC HydroGeo Environmental,LLC „a,. Crozet,Virginia February 16,2015 wr __ References Environmental Data Records Radius Report for Albemarle County Parcel #57-31A (Inquiry#4182090.2s) low Albemarle County Hvdrogeologic Assessment Summary Report by ENSAT Corporation and Albemarle County Department of Engineering and Public Works(2003) err Albemarle County GIS Web: http://gisweb.albemarle.org/Map/Viewer.aspx ,r Heath, R. C. 1980. Basic elements of groundwater hydrology with reference to conditions in North Carolina: USGS Water Resources Investigations Open-File Report 80-44, 86p. LeGrand, H. E. 1988. Region 21, Piedmont and Blue Ridge. in Back, W., Rosenstein,J. S.,and Seaber, P. R.,eds., Hydrogeology: Boulder,Colorado,Geological Society of America,The Geology of North " America, v. 0-2. ..r VADEQ online Environmental GIS data: http://www.deq.virginia.gov/mapper_ext/default.aspx NOW Virginia Division of Mineral Resources, 1993, Geologic Map of Virginia: Virginia Division of Mineral Resources,scale 1:500,000 Noy +rr► liesy war ler vow vow %r. Nor Nor r.• ..r INF