Loading...
HomeMy WebLinkAboutSUB201500025 Review Comments 2015-03-06Short Review Comments Report for: SUB201500025 SubApplication Type: Emerson Commons - Easement 2 Easement Plat Date Completed:03/06/2015 Reviewer:Ellie Ray Planning Review Status:Requested Changes Reviews Comments: Division: Date Completed:03/06/2015 Reviewer:Alexander Morrison ACSA Review Status:No Objection Reviews Comments: Division: Date Completed:03/04/2015 Reviewer:John Anderson Engineering Review Status:See Recommendations Reviews Comments:1.Extend 12’ and variable width access easement for (SWM facility) inspection and maintenance from point D2 (underground detention/ref VSMP-WPO201400038) and B2 (bioretention facility) to a natural stream, or property line if natural stream is beyond PL. [ref. 18-32.7.4.2.b] 2.Show stream buffers if and where intersection occurs with Drainage Easement (item #1) 3.Show Approximate Location of Flood Zone ‘A’ (100-yr floodplain) if and where intersection occurs with Drainage Easement (item #1) 4.Revise Title (include ‘Drainage’): A New 12’ & Variable Width Drainage Access Easement for Inspection and Maintenance, for example. 5.Show and label Parrot Branch, sheet 1 of 2 (Drainage Easement). Ref. Pvt. Sanitary Sewer Easement (1 of 1) for sample stream depiction. 6.Revise Note 4, to include ‘Drainage’ –see comment #4, above. 7.Revise Easement Area –will increase above 18,634 SQ. FT. 8.Recommend inset detail for L6 and L12, but not required. 9.A New 20 Foot & Variable Width Private Sanitary Sewer Easement, Easement line table: Confirm L1, L2 bearings are accurate. L1 appears to bear NW, L2 appears to bear NE (or both NW). 10.Pvt. Sanitary Sewer Easement: Provide delta and radius for 14.46’ Arc Tie (PL at Parkview Drive). janderson2 3/4/2015 5:27 PM Division: Date Completed:04/29/2015 Reviewer:Ellie Ray Planning Review Status:No Objection Reviews Comments: Division: Date Completed:05/08/2015 Reviewer:John Anderson Engineering Review Status:See Recommendations Reviews Comments:All prior comments Addressed, or partially addressed. As follow-up, please: 1.Extend 12’ and variable width access easement for (SWM facility) inspection and maintenance from B2 (bioretention facility) to a natural stream, or property line if natural stream is beyond PL. [ref. 18-32.7.4.2.b] 2.Revise Access Easement Area –will increase above 19,791. janderson2 5/8/2015 7:13 PM Division: Date Completed:06/08/2015 Reviewer:John Anderson EngineeringDivision: Page:1of2 County of AlbemarlePrinted On:January 29, 2016 Review Status:No Objection Reviews Comments:Prior comments addressed. Date Completed:10/01/2015 Reviewer:Ellie Ray Planning Review Status:No Objection Reviews Comments: Division: Date Completed:09/23/2015 Reviewer:John Anderson Engineering Review Status:No Objection Reviews Comments: Division: Date Completed:01/21/2016 Reviewer:Ellie Ray Planning Review Status:Approved Reviews Comments: Division: Page:2of2 County of AlbemarlePrinted On:January 29, 2016 Planning Application Review for SUB201500025 Emerson Commons - Easement 2. Page 1 of 1 Planning Application Review for SUB201500025 Emerson Commons - Easement 2. John Anderson Sent:Wednesday, March 04, 2015 5:29 PM To: Ellie Ray The Review for the following application has been completed: Application Number= SUB201500025 Reviewer=John Anderson Review Status= See Recommendations Completed Date = 03/04/2015 Comments in CV—not shared with Applicant—thanks for your patience, Ellie: "1. Extend 12' and variable width access easement for(SWM facility) inspection and maintenance from point D2 (underground detention/ref VSMP-WP0201400038) and B2 (bioretention facility)to a natural stream, or property line if natural stream is beyond PL. [ref. 18-32.7.4.2.b] 2. Show stream buffers if and where intersection occurs with Drainage Easement (item #1) 3. Show Approximate Location of Flood Zone `A' (100-yr floodplain) if and where intersection occurs with Drainage Easement(item #1) 4. Revise Title (include `Drainage'): A New 12' & Variable Width Drainage Access Easement for Inspection and Maintenance, for example. 5. Show and label Parrot Branch, sheet 1 of 2 (Drainage Easement). Ref. Pvt. Sanitary Sewer Easement(1 of 1) for sample stream depiction. 6. Revise Note 4, to include `Drainage' —see comment#4, above. 7. Revise Easement Area—will increase above 18,634 SQ. FT. 8. Recommend inset detail for L6 and L12, but not required. 9. A New 20 Foot& Variable Width Private Sanitary Sewer Easement, Easement line table: Confirm L 1, L2 bearings are accurate. L 1 appears to bear NW, L2 appears to bear NE (or both NW). 10. Pvt. Sanitary Sewer Easement: Provide delta and radius for 14.46' Arc Tie(PL at Parkview Drive). janderson2 3/4/2015 5:27 PM" https://webmail.albemarle.org/OWA/?ae=Item&t=IPM.Note&id=RgAAAABu2168UE 10S7i... 3/6/2015 Ellie Ray From: John Anderson Sent: Friday, May 08, 2015 7:15 PM To: Ellie Ray Subject: Planning Application Review for SUB201500025 Emerson Commons- Easement 2. The Review for the following application has been completed: Application Number=SUB201500025 Reviewer=John Anderson Review Status =See Recommendations Completed Date =05/08/2015 Thanks for your patience, Ellie—CV comments have not been shared with Applicant: "All prior comments Addressed,or partially addressed. As follow-up,please: 1. Extend 12'and variable width access easement for(SWM facility)inspection and maintenance from B2 (bioretention facility) to a natural stream,or property line if natural stream is beyond PL. [ref. 18-32.7.4.2.b] 2. Revise Access Easement Area—will increase above 19,791." 1 Ellie Ray From: Ellie Ray Sent: Monday, June 08, 2015 4:42 PM To: 'Kevin Conner'; Jo Higgins Subject: SUB201500021, 25, 26 &27 Emerson Commons Easement Plats 1-4 Kevin/Jo, I have reviewed the easement plats and have the following comments, broken down by SUB#: • SUB201500021 Easement 1: o My previous comments have been addressed. o All other reviewers had no objection to previous submittals. o This plat is ready to be signed by the owner(s) and submitted for County signature. o Engineering has reviewed the plat and their prior comments have been addressed. o All other reviewers had no objection to previous submittals. SU B2015Y" r �"�.�::�K`'��...� » . • 00026 Easement. "`-" '` o My previous comments have been addressed. o Engineering has reviewed the plat and their prior comments have been addressed. o All other reviewers had no objection to previous submittals. o This plat is ready to be signed by the owner(s) and submitted for County signature. • SUB201500027 Easement 4: o My previous comments have been addressed. o Engineering has reviewed the plat and their prior comments have been addressed. o We are awaiting ACSA review. Their comments, if any,will be forwarded upon receipt. o Once ACSA approval is granted,the plat will be ready to be signed by the owner(s) and submitted for County signature. Feel free to contact me if you have any questions, concerns, or need further clarification. Thanks, Ellie Carter Ray, PLA,LEED GREEN AESOCIATE Senior Planner Albemarle County Community Development Planning Division 401 McIntire Road, North Wing Charlottesville,Virginia 22902 ph: 434.296.5832 x. 3432 fax: 434.972.4126 1 Ellie Ray From: John Anderson Sent: Monday, June 08, 2015 8:51 AM To: Ellie Ray Subject: Planning Application Review for SUB201500025 Emerson Commons- Easement 2. The Review for the following application has been completed: Application Number=SUB201500025 Reviewer=John Anderson Review Status = No Objection Completed Date =06/08/2015 CV comment: "Prior comments addressed."—thanks for your patience, Ellie Comments not shared with Applicant. i