Loading...
HomeMy WebLinkAboutSDP200800092 Application 2008-05-30 n C j County of bemar/e unity Development Department,Zoning& Current Development Division ti 401 McIntire Road Charlottesville,VA 22902-4596 Planning Application 1 Voice (434)296-5832 Fax (434)972-4126 PARCEL/ OWNER INFORMATION IMP v 07600-00-00-012A0 Owner(s)' ,WH`FONTAINE.ACQUISITION CRC Application#1'm $ppi00800092 PROPERTY INFORMATION Legal Description ACREAGE Magisterial Dist. Samuel Miller Land Use Primary Open Current AFD Not in A/F District Current Zoning Primary Planned Residential Development APPLICATION INFORMATION House # Street Name Apt/Suite City State Zip Street Address Entered By: Eileen Wittwer on 05/30/2008 Application Type Site Development Plans Project: Fontaine Townhomes-Minor 5,947.00 Received Date 05/30/2008 Received Date Final Total Fees $95.00 Submittal Date 05/30/2008 Submittal Date Final Total Paid $95.00 Closing File Date Revision Number Comments: Legal Ad SUB APPLICATION(s) Type Sub Application Date Comments Minor Amendment 05/30/2008 APPLICANT/ CONTACT INFORMATION Primary Contact Name Ammy George-Timmons Group Phone# (434) 327-1684 Street Address 919 2nd St S.E. Fax# (434) 295-8317 City/State 'Charlottesville,VA Zip Code 22902-0000 E-mail ammy.george@timmons.com Cellular# ( ) - Owner/Applicant Name WH FONTAINE ACQUISITION LLC Phone# (434) 296-9484 Street Address 703 E JEFFERSON ST Fax # (434) 296-2560 City/State CHARLOTTESVILLE VA Zip Code 22901- E-mail frank@weatherhilldev.com Cellular# ( ) - Applicant Name W. H. Fontaine Acquisition LLC Phone # (434) 296-9484 Street Address 703 East Jefferson St Fax# (434) 296-2560 City/State Charlottesville,Va Zip Code 22902-0000 E-mail frank@weatherhilldev.com Cellular# ( ) - Signature of Contractor or Authorized Agent Date WITH AN x N Per Zoning Ordinance Application t Jr Major & Minor Site Fran Amendments and All Reinstatements of Denied or Deferred Site Plans ''` ❑Major Amendment(Subject to Planning Commission Review)=$270 rtYlinor Amendment(alterations to parking,dredation, 17 folded copies of plea are required building size,location)=$95 8folded copies of sketch plan are required ❑Reinstate Plan Review After 10 day Denial=$200 ❑Reinstate Plan After Site Review Denial or Suspension=S65 ❑Reinstate Plan Deferred by Applicant ❑Toa specific date=$35 ❑Indefinitely=$75 17 folded copies of plan are required Was a groundwater review conducted for the existing site plan? ❑YES ❑NO If YES:What is the average gallons of water used per day for the existing use(s) ? and What is the NEW average gallons of water used per day? If NO:What is the average gallons of water used per day for the all use(s) ? ❑ Tier 3 Groundwater Review=$400 plus$25 per dwelling unit (Bemired for all plans shewins a use that uses less than 2.000 rallons of muter oer day averare) ❑ Tier 4 Groundwater Review=$1,000 (Repaired for all plans showinr a use that uses neater than 2.000 rallonsif water set.day average) ❑Relief from conditions of approval from Planning Commission or landscape waiver by agent=$180 ❑Extension of approval prior to expiration of an approved plan=$45 ❑Rehearing of Site Development Plan by the Planning Commission or Board of Supervisors=$190 ❑Appeal of Site Development Plan to the Board of Supervisors=S240 Project Name: �n�CU r1� TouxtV1f1(1.3PS Tax map and parcel: le—t 2 A d- 12.. ( Magisterial District:5arnue.1 X1,11 Lee Zoning:Kb.ark -2O04-o1. Physical Street Address(if assigned): 3O4 3CY Fbrl4QAt1e- AVOW( 2.1C • Location of property(landmarks,intersections,or other): NO r Mn-VJ-eS#' GO(rrtr 0 k Ro -t. 102_ `1' Q e ZO -� u.,� Contact Person(Who should we call/write concerning this project?): 1 1�V�, .cy C-1rc 4)) % A to tv 0 Address a lO( Znd Sf - S•E . City C ecir to-Res vi Ilk state VIA zip X2.502 Daytime Phone E 3 1�) 37 • I`84 Fax#�J+4 ZqS-e3I J E-mail Glrn nti 1, .9covz e N Ac v1S-Ltd'►' Owner of Record W• �{. 'FOtl1�G�,1+12 A C G i A1�St"�l On 1 1 .0- Cl0 r-rcutj 1)0 Address cD3 E t 4- se-�-CCk- ,Dn S�- - city C ur Lo+ ttA lie state l/a Zip 2ZCjO7- Daytime Phone d Zq(p •QqB-4 Fax#M346 2Q(0• 2.5((O E-mail -PrAV 1lC_ ekAleCt.:6t r�t l Idev.wpvl Applicant(Who is the Contact person representing?): W W. 4. F- - 51,t`1 f�v� L LC i �Y_f`� - told Address �3 ACC 3 - Ze-C-Cer r City C)V10llr\c kt v►Ile_ State to Zip 2gOZ Daytime Phone('- 29 to •Q k Q,q Fax# 25(p • ZS 60 E-mail -ccuil1,c.. VUeSlIke rirt1 LI c es)• W -& FOR OFFICE USE ONLY SDP# A 09 d'- 7).. UD Fee Amount S 9S Date Paid 131(] who?W0C X H i((_ Receipt#1 I(J� Ck#33`J By: County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 5/1/06 Page 1 of 2 Intended use or iustificaon for request: Nii"' Owner/Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5(Preliminary Plan)or Section 32.6(Final Plan)of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten(10)days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.3 as the case may be. For Final Plans Only: To the best of my knowledge,I have complied with Section 32.4.3.1 and obtained tentative approvals for all applicable conditions from the appropriate agencies. --1, -(4 s-73v 7o) Signature of Owner,Contract Purchaser,Agent Date f`1rtZ G /Poly,CUB �3of- z SG- sslpy Print Name Daytime phone number of Signatory 11//19/07 Page 2 of 2 i Site i n al Development. r Ian :fa 11;1,-..4141 -—tilit'L't Checklist Project Name: Fom-mime "RAW HPME 5 Firm:. TIMM omS Gruxiil This checklist wig be complettx4 signed and Submitted with the application. The information contained in this checklist Mike&the contents ofthe Site Plan Ordinance as of/Jay 4 2006. The applicant is responsible for insuring that no re*ions to the Ordinance have occurred since preparation of this docunrent A r!' , ,I Site Development Plan shall contain the follo*ing: [r-J Preliminary approVal letter with appropriate number of copies of the plan U Written regnest fOr any waivers(attach to application): Please List: Site Plan Ordinance SeCtion 31,6-Contents of final site plan In additio: n to containing all of the information,required by the Contents of Preliminary Site Plan(section 32.5)a final site plan shall contain the following: W1(1.A.final site plan together with amendments thereto shall be prepared and sealed,signed arid dated by an architect, professional engineer,land surveyor,or certified landscape architect,each of whom shall be licensed to practice in the Commonwealth of Virginia. [326:11 lia72--.-A final site plan shall be prepared on mylar,sepia or other such transpareney material Which ahall he termed as the master drawing. Two(2)clearly legible blue or black line copies of the master drawing shall be submitted to the department of planning and community development (Added 5-1-87) In addition,if review is required by the commission,one(I)reduced copy no larger than eleven(11)inches by seventeen(17)inches in size shall be submitted. [32:6.2] Fi73.TWo(2)copies of a landsCape plan dial be submitted with the final site plan if not previously submitted. [32.6.3]. Vrt.When the site plan is ready for final approval,the fUll-sized revised master drawing and a transparency-Copy of the master drawing shall be submitted for the agent's signatUre. Once the agent has signed the master drawing,he shall return the master drawing to the developer and the developer shall submit four(4)print.copies of the signed master drawing to the agent. [32.6.4] liK.Unless otherwise approved by the agent,the final site plan shall be prepared to the scale of one(1)inch equals twenty(20)feet or larger or to such a scale as may be approved by the agent in a particular case;no sheet shall exceed thirty-six(36)inches by forty-two(42)inches in size. The site plan may be prepared on one(1)or more sheets, If prepared on more than one(1)sheet;match lines shall clearly indicate where the sheets join. The top of the sheet shall be approxiMately either north or east. [32.6.5] Earr--6.The final site plan shall.refit conditions of-approval Of the preliminary site plan. The final site plan ilia con • the following infortnation in addition to all the information required on the preliniinaty site plan:[32.6.6] uSpecific written schedules or notes as necessary to demonstrate that the requirements of this chapter are being satisfied. In addition to preliminary site plan information,indicate if sale or rental units;number of bedrooms per unit,and number of units per building if multi-family;specifications for recreational fadilities. [32.6.64 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice (434)296-5832 Fax: (434)972-4126 5/1/06 Page 1 Of 3 178.Proposer'grading(up to twenty PO]percent slope,Maximum two[2] foot contours; over twenty[2O]percent slpe,rnaximumfiv. feet contours). 132.6.6b] 9.•Detarled:plans for*worm('water and sanitary sewer facilities,including: all pipe sizes,types and grades; proposed connections to existing or proposed central systems,location and dimensions of proposed easements and whether the same are to be publicly or privately Maintained;profiles and cross sections of all water and sewer lines including clearance wire*lines cress,all water Main locations-and sizes;valves and-fire hydrant locations,all sanitary sewer appurtenances by type and number; the station on the plan to conform to the station shown on the profile and iudieate the topand invert elevation of each structnre:[32.6.64 1314.0:Detailed construction dra.bage and.grading plans: 1. Pnifiles of all ditches and channels Whether proposed or existing,showing: existing and proposed grades,and invert of ditches„cmss pipes or utilities;typical channel cross sections for new constriction,and actual cross sections for existing channels intended to remain; 2. Profiles of all Morin sewer systems showing existing and proposed grades; 3., Plan view of all drainage systems with all structures,pipes,and channels numbered or lettered on the plan and profile views. Show sufficient dimensions and bench marks to allow field stake out of all proposed work from the boundary lines; 4. A drainage summary table for culverts,storm sewer and channels as described in the following example: Structure Number Description Length Invert in Invert out Slope Remarks (1) 42"RCPClass III 50" 424.50 424.00 100:00% Provide 2,EW (2) D1-.3B .Etrg 426.00 432.00 - IS-I Top (3) PG-2A 400' 420.00 400.00 5.00% l'. 12" (4) Grade Swale 2.00' 420.00 415.00 250% I', 18" 5. A legend showing all symbols and abbreviations used on the plan; 6., General notes,typical sections,and details of all items not covered by Virginia Department of Transportation Standard draWings; 7 Flood plain limits for the one hundred year storm for all watercourses with an upstream drainage area of fifty(50) acres or more provided that the county engineer may waive this requirement for drainage areas of less than one hundred(100 at:ark upon determination that such information is unnecessary for review of the proposed development. /32.6.64/ I51‘.Typical street sections together with specific street sections where street cut or fill is five(5)feet or greater; centerline curve data;radius of curb returns or edge of pavement;location,type and size of proposed ingress to and egress from the site;together with culvert size;symmetrical transition of pavement at intersection with existing street;the edge of street surface or face of curb for full length of proposed street;when proposed streets intersect with or adjoin existing streets or travel-ways,both.edges of existing pavement Or travelWay together with curb and gutter indicated-kr a mininnim of one hundred(100)feet or the length of connection,whichever is the greater ., .-.132.6.6d 1.1 i 12 Ignature panel for Deparunent of Community Development. [3,2.6.6J] 13.For all parking and loading areas,indicate:size;angle of stalls;Width of aisles and specific,number Of spaces required Mulpmvided,and Method of computation. Indicate type of surfacing for all paved or gravel areas. Ci1/4fnigl P - 14.The final site development plan shall be dimensioned to at least the following standard's for accuracy: L Boundary,setback and zoning lines-nearest one-one hundredth(0.01)of a foot; 2.Existing contours 4 One-half(h)of the contour interval required in section 32.6.6:b above; 3.Proposed contents-Within one(1)foot horizontally and vertically; 4..Spot elevations-within one4enth(0.10)ola foot; S.Existing structures,utilities and other topographic features-within-two(2)feet For critical structures,accuracy should be within.one-tenth(0.10)of afoot; 6. roads,parking lots,and.other improvements.-within one hundredth(0:01)of a foot [32:6,6h] 15.Landscape plan in conformance with section 32.7.9.[32.6.6i/ 5/1/06 Page 2 of 3 U 16.Outdoor lighting information including a photometric plan and location,description,and photograph or diagram 1V/4 °reach type of our luminaire.[32.6.611 In addition to the items required by the ordinance,Albemarle County Engineer, Groundwater Program Authority,the Virginia Department of Transportation,the Albemarle County Service Authority,and the Thomas Jefferson Health District require these items on plats and plans submitted for pr. 1 0 airy approval- Plats and plans will not be rejected if these items are not present,but they are required fur approval. These items are provided in an effort to communicate all preliminary comments. Itiak Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) 12,4.-Indiatte the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) Label the maximum.height of all retaining walls. ( bemarle.COunty CountyEngineering Policy) 0:0 4.Provide copies of off-site easements,or letters of intent to grant them from off-site property owners. (Albemarle Co) unty-Engineering Policy) , VII'5.Show and label stream Wier limits. (WRPA Ordinance). Indicate the deed boolc and page reference for all existing•utility easements located on the property. (Albemarle. County Service Authority) El 7.Tier 3-Draft or Final Groundwater Management Plan(17-403) aym El 8.Tier 4—Aquifer testing work plan(17-403) kiii4 Read and Sign In representing the above referenced firm submitting this plan for final approval,I hereby sate that,to the best of my kno wledge,the ae• hed plan contains all information required by this checklist. , 5-/30/09 Si of 0 ,Contract Purchaser,Agent Date CH(LtS7dekie(a a-4%24 9014—839—Print — Paint Name. Daytime phone number of Signatory 5/1/06 Page 3 of 3 • TIMMONS GROUP TOUR VISION ACMISTED THROUGH OURS. TRANSMITTAL To:Wri ck 1 a j nc e... Dater 5 Jo )cs Job #: 2Z I' pt.Ih, Cr,o4.+ (rim . N>,)• Project: -r.Nn-4rtiCvu T)1A,r)\rmMI,vv Reference: Copies Sent to: From: C In ri s Cl ar k ® Enclosed Please Find: 0 We are Sending Under Separate Cover: Copies Date Number _Description I 5 c7 22�t�u (2, 4,l ci-I-e.- Oetr, �,e e U o-4- , 1 S-30 77 x1 Kv- pi ii Of fl17npwUnnIA4- I S-.36• 221h)V , 4 S.�^' �-ee Gl�ncl-c, 30 'Z20� ( (7iv SwM / rtP Phi,s •3O. U 27.3f� (-Pe 0,1_90[_ (sO,/O S •3)•(./2/ 229-0'I I o fFci fir, Na. 'i c,k Y(Ac� op 5 '30 -0 8 22�oy M�na� s,!-e_ Meth Ampvdn'in , 3 5 .3P •O5' 22'4-0u 'a-- Ploiri el These items Are Transmitted:VIA �and I)r,l\vei, - lf enclosures are not as noted,please no*us at once. Comments: Questions or Comments please call: C ifi n's C' tar 80 (•p3q•is 1 a• Received by: Signature Date Print Name: 0 • TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS p s0 Ii Nt- co May 30,2008 Mr. Patrick Lawrence o County of Albemarle r7, Department of Community Development N 401 McIntire Road 8 M Charlottesville,VA 22902-4596 LL U, Re: Fontaine Townhomes N (+1 N tri Ln C Dear Mr. Lawrence: N M• ,D Please find attached eight(8) copies of the minor site plan amendment for the Fontaine W 0 Townhomes,WPO-2005-00094 and SDP-2005-00094, and three(3) copies of the o a Erosion and Sediment Control Plan. This minor site plan amendment revised lots 1-6 and N o 21-49,which maintains the approved number of units per the property's rezoning case, o revised the stormwater management plan to include storm filters as opposed to bio-filters, > N revised the grading to better match the existing conditions of the site, and revised the . parking throughout the site. 7, 4_ o o_ If you have any questions, concerns, or comments please do no hesitate to contact me at 434-327-1690. 6711 Vio Best Regards, Lou V, V w c O N C 'tE Z Christopher B. Clark, P.E. Project Manager V O yl C C U O E v C m `C b c w v a, C d E 0 0 v > v O w U,