HomeMy WebLinkAboutSDP201600010 Review Comments Final Site Plan and Comps. 2016-03-01Phone 434-296-5832
'AL
IH[;Stit
County of Albemarle
Department of Community Development
401 McIntire Road,
Charlottesville, VA, 22902
Memorandum
To: Devin Keeler (dkeller@dewberry.com)
From: Rachel Falkenstein, Senior Planner
Division: Planning
Date: March 1, 2016
Subject: SDP 2016-11 UVA Foundation Golf Facility — Final Site Development Plan
Fax 434-972-4126
The County of Albemarle Planning Division will recommend approval of the plan referenced above once the
following comments have been satisfactorily addressed (The following comments are those that have been
identified at this time. Additional comments or conditions may be added or eliminated based on further
review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning
Ordinances unless otherwise specified.]
[SP Condition 3] Include a sheet showing the entire Birdwood golf course site. The sheet does not
need to be an as built plan, but should show existing facilities on golf course to use as a baseline for
future amendments or site changes.
2. [Comment] Provide a more legible key for review, to include page numbers.
3. [32.5.2 (a)] Interior property lines have been vacated with a recent boundary line adjustment plat.
Show updated property lines, TMPs and deed book/page numbers.
4. [32.5.2 (a)] Include a description of the special use permit (SP23015-19) and conditions thereof on
final site plan.
5. [32.5.2 (a)] Include the source of survey and source of topography.
6. [32.5.2 (a)] Include names of owners, zoning district, tax map and parcel numbers and present uses of
abutting parcels.
7. [32.5.2 (d)] Identify areas of the site where existing slopes are steep slopes
8. [32.5.2 (e)] Identify whether existing wooded areas are composed of evergreen, deciduous or mix of
type.
9. [4.17(a) & 32.6.2(k)] Provide manufacturer's information for proposed lamp types to confirm the
lumens. The luminaire schedule notes a 150 watt high pressure sodium lamp for the light fixtures. 150
watts exceeds the ordinance equivalent for 3000 lumens, and requires the use of a full cutoff fixture.
10. [32.7.9.4(b)] Show existing trees to remain, if any, on landscape sheets.
11. [32.7.9.4(b)] Include signed conservation checklist on landscape plan.
12. [32.7.9.6(a)] An area of at least five (5) percent of the paved parking and vehicular circulation area
shall be landscaped with trees/shrubs. The plant materials may be a mixture of shade trees and shrubs
and shall include one (1) large or medium shade tree per ten (10) parking spaces or portion thereof.
Provide calculations to confirm these requirements are met.
13. [32.7.9.8(a)] There is a minimum tree canopy requirement for this site of 10 percent (note that
outdoor recreation areas such as driving range can be subtracted from the area for this calculation).
Provide calculations to confirm this requirement is met.
14. [32.6.1(h)] Include signature panel for each member of site review committee.
15. [Comment] Label maximum height of all retaining walls.
16. [Comment] Elevations are not required as part of the site plan and can be removed from the plan set.
17. [Comment] Approvals from engineering, ARB, ACSA, Fire Rescue and VDOT are required prior to final
approval. Comments from ARB and engineering are attached. Additional comments, if any, will be
forwarded upon receipt.
Please contact Rachel Falkenstein in the Planning Division by using rfalkenstein@albemarle.org or 434-296-
5832 ext. 3272 for further information.