HomeMy WebLinkAboutSDP201000074 Plan - Approved 2010-11-30GENE R A L N O T E S: 1. ACCESS TO ATM IS DESIGNED AND FIELD BUILT BY OTHERS AND IS SUBJECT TO LOCAL JURISDICTION APPROVAL. 2, ALL DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUAL OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT BE USED, 3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS. WHOSE BOTTOM EDGE IS LESS THAN 50 INCHES ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE SAFETY, TEMPERED, OR ACRYLIC SHT. 4. FLOOR DESIGN LIVE LOAD 125 PSF. 5. MAXIMUM WIND SPEED -- 150 MPH EXPOSURE "C" 6. SEISMIC CATEGORY "C" 7. OCCUPANCY IS STORAGE /BUSINESS (DEPENDING ON STATE) 8, OCCUPANT LOAD IS BASED ON 1 PERSON PER 300 SOR. FEET OF FLOOR AREA. FOR (S2) STORAGE & 100 S/F FOR BUSINESS 9. ROOF DESIGN LIVE LOAD — 40 PSF. 10. UNLESS OTHERWISE SPECIFIED, ALL STEEL MUST COMPLY NIITH ASTM A36, YIELD STRENGTH = 36 KSL 11, ALL BOLTS MUST COMPLY WITH ASTM A325. 12. EXT. WALL FIRE RATING ,Q HOUR BASED ON PTO FT. NOTES TO BUILDER AND /OR SITE DEVELOPER 13. ALL SITE WORK, INCLUDING THE LOCATION OF THE BUILDING MAY BE REQUIRED TO BE REVIEWED AND APPROVED BY A LOCAL REGISTERED ARCHITECT OR ENGINEER TO VERIFY CODE COMPLIANCE INCLUDING, BUT NOT UMrrED TO FIRE RESISTANCE RATING FOR EXTERIOR PROTECTION, MEANS OF EGRESS, HEIGHT AND AREA LIMITATIONS AND OTHER PERTINENT SITE — RELATED MATTERS. 14, WHERE APPLICABLE, CONSTRUCTION DOCUMENTS, INCLUDING SITE AND DEVELOPMENT DRAWINGS, SHALL BE SUBMITTED TO THE LOCAL GOVERNMENT AGENCY FOR REVIEW AND APPROVAL BY THEM VIA THE NORMAL INSPECTION AND PERMIT PROCESS. E i E C T R I G A L IN 0 I E S: N E C ELECTRICyAL CI R IT N OTES: RaH =icn- n 8l87lGa UW,1T£Y.� ccH.'�s: I. ALL CIRCUITS AND REQUIREMENTS SHALE. BE GROUNDED IN ACCORDANCE WITH APPROPRIATE ARTICLES OF THE STATE HWC PLAN #`S FLORIDA GEORGIA NATIONAL ELECTRICAL CODE (NEC). N. CAROLINA S. CAROLINA. 1 MARYLAND VIRGINIA 1978 -0554 WEST VIRGINIA DISCONNECTS ADJACENT TO THE EQUIPMENT SERVED, A UNIT TENNESSEE - BREAKER 20 AMP KENTUCKY SWITCH WITH A MARKED `OFF" POSITION THAT IS A PART OF THE E i E C T R I G A L IN 0 I E S: N E C ELECTRICyAL CI R IT N OTES: RaH =icn- n 8l87lGa UW,1T£Y.� ccH.'�s: I. ALL CIRCUITS AND REQUIREMENTS SHALE. BE GROUNDED IN ACCORDANCE WITH APPROPRIATE ARTICLES OF THE MAIN PANEL 10C AMP, 12 CIRCUIT, SINGLE PHASE, SURFACE MOUNT N NATIONAL ELECTRICAL CODE (NEC). 8 o I� h 1 2. HVAC EQUIPMENT SHALL BE PROVIDED NI/ READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE EQUIPMENT SERVED, A UNIT CIRCUIT 1 - BREAKER 20 AMP SWITCH WITH A MARKED `OFF" POSITION THAT IS A PART OF THE #12 WIRE HVAC EQUIPMENT AND DISCONNECTS ALL UNGROUNDED 5 AMPS 0 120 VOLT CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING CEILING FIXTURE & FANS MEANS WHERE OTHER DISCONNECTING MEANS IS ALSO PROVIDED BY A READILY ACCESSIBLE CIRCUIT BREAKER. CIRCUIT 2 - BREAKER #3 - 20 AMP - #12 WIRE 3. PRIOR TO ENERGIZING THE ELEC. SYSTEM, TIME INTERRUPTING - APPROX. 15 AMPS 0 120 VOLT RATING OF THE MAIN BREAKER MUST BE DESIGNED & VERIFIED - OUTLET FOR ATM AS BEING IN COMPLIANCE WITH SECTION i 10 -9 OF THE NEC BY LOCAL ELECTRICAL CONSULTANT. CIRCUIT 3 -- BREAKER #5 - 20 AMP - #12 WIRE 4. THE MAIN ELECTRICAL PANEL FEEDERS ARE DESIGNED AND - MAX. 12.5 AMPS 0 120 VOLT INSTALLED BY OTHERS AND ARE SUBJECT TO LOCAL -- DUPLEX OUTLETS LL.( JURISDICTION APPROVAL. CIRCUIT 4 — BREAKER #7 - 20 AMP Iii — x{12 VVIRE MAX. 15 AMPS @ 120 VOLT U) — RECEPTACLE STRIPS OUTLETS W CIRCUIT 5 — BREAKER #9 — 20 AMP — #12 NITRE -, — MAX. 15 AMPS 0 120 VOLT — EAGLE MONEY MOVER 0 CIRCUIT 8 — BREAKER #11 — 20 AMP 0 — #12 WIRE (J) — MAX. 15.0 AMPS 0 120 VOLTS � — EAGLE MONEY MOVER `— (D 10 CIRCUIT 7 _ BREAKE 2 — 20 AMP .1 _ # 12 WIRE — 12.0 AMPS 0 120 VOLT {_) L — AIR CONDITIONER 0 CIRCUIT 8 — BREAKER #6 — 30 AMP � (� — #10 MIRE z Q — 15.0 AMPS (EA. END) 0 120 VOLTS — 'HAMILTON HT -15" MONEY MOVER x�I JAI 0 r 2008 \/ r qy CIRCUIT 9 — BREAKER #8 — 20 AMP — # 10 MIRE MAX. 12;6 AMPS ® 120 VOLTS — WALL /CEILING HEATER TOTAL = 132.1A X 120V = 15,852 KVA 15,852 KVA /240V = 68.05 AMPS SEE LABELED PANEL DOOR FOR EXACT CIRCUIT IDENTIFICATION NOTE. LOCAL ELECTRICAL CONTRACTOR MUST GROUND THIS UNIT IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE & ANY LOCAL CODES THAT MAY APPLY. a lyl REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33755 PHONE: (727) 796 -8774 FAX: (727) 791 -6942 THIS UNIT EQUIPPED WITH "UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SVtlACE TO MAIN PA Ra NOT SY CONOMT. FINAL HOOK —UP NOT BY CONCEPT Tt PARTY: HILBCSN, VERMEIL CARTER.... & ASS4UATES, INC. 1627 SOUTH UvRnr AIM IXEM.WATER, iL. M7f6 Vent Destgner. Sa$ft an: Drawn sy. S. SPIGNER Checked By Dote: 9,/25/2005 Draw4rtg No- B -1745 Sh"t Of 1 6 a M N 8 o I� h 1 iC D y Vent Destgner. Sa$ft an: Drawn sy. S. SPIGNER Checked By Dote: 9,/25/2005 Draw4rtg No- B -1745 Sh"t Of 1 6 7 -11° 1 r— n R -MR: 2, FRONT ELEVATION 2' -1`' I LI rn F% iii I ire OPENING TO BE FIELD CUT .090* ALUM. PANEL Vl/ A STIPPLE URFTKANE FINISH ALL SURFACE COPY PAINTED — WHITE WITH A SMOOTH FINISH MG GREY DOOR SCOPE — BOLLARDS NOT BY CONCEPT —MIN. 12' THK CONCRETE ISLAND NOT By CONCEPT PAVED SURFACE ---ti N I I k I' VARIES THIS MEASUREMENT IS TO SLIDER FLOOR FROM TOP OF NOTE: HEIGHT OF PAD FROM PAVED SURFACE CONCRETE PAD NEEDS TO BE SET ACCORDING TO (BOTTOM OF ATM TO CONCRETE PAD) ATM ADA REQUIREMENTS.(NOT BY CONCEPT)_ REAR ELEVATION 51-0. L s- :W2- — 7 LEFT ELEVATION ALL GRAPHICS AND COLOR COMSINA'nONS TO FOLLOW ON GRAPHICS SHEET W—C 2' -11' BB&T GREY STIPPLE URETHANE FINISH. 'GE * A/C GRILL 70 BE PANTED TO MATCH BUILDING COLOR IS D A/C UNIT NEEDS TO BE REMOVABLE FROM OUTSIDE OF BUILDING, BB&T BURGUNDY STIPPLE URETHANE FINISH. BB&T GREY STIPPLE URETHANE 2 FINISH. V-6" 6 1/2- 8 &T BURGUNDY STIPPLE FURETHANE FINISH. BB&T GREY STIPPLE URETHANE FINISH. 6 1/2- BB&T BURGUNDY STIPPLE URETHANE FINISH. BB&T GREY IN 111111 URETHANE FINISH. STIPPLE NOTCH THIS AREA INSIDE BACK DOOR TO FIT CHEOUE ACCEPTOR. CRITICAL DIMENSION PLEASE GIVE THIS MUCH TRAVEL BEHIND NOSE MINIMUM D,O.T. -STOP- SIGN r,/ REFLECTIVE RED BACKGROUND AND REFLECTIVE ;rTE BORDER AND COPY 4 1/2' GENERAL NOTES • EXTERIOR SKIN 090' ALUMINUM • INTERIOR SKIN M206 AL. PAINTED ViNHE ATIA NOSE . 090' ALUMINUM. * EXTERIOR FINISH STIPPLE POLYURET�fft 0 CONCRETE ISLAND, cuA.RD POSTS tz UfiLm6S NOT By CONCEPT. I f i� � rI MIN. TRAVEL BEHIND NOSE 7 0 Voptional cheque ocoaptor 3'-6 1/4" —1 r- -6'-10" EXTENDED NCR 5886 M SERIES CURRENCY DISPENSER . SHORT SLEEVE I - DATA NOT BY VIDEO CONCEPT —MAIN — SECURI — PHONE THIS UNIT EQUIPPED VATH **UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SERVICE TO MAIN PAM NOT sy cotxwTl I FINAL HOOK—UP NOT BY CONCEPT TIM PARTY; M-SWI. %VWER, CMTM & ASSDCFAT" INC 1627 SCOrrt U)NA.9 AVIL CLUAWAIIR, FL 337$6 1101 RIGHT ELEVATION --NOTE*- MUST LOCAL GROUND THIS ELECTRICAL C A UNI ONTRCTOR krpROV T IN ACCORDANCE PATH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY APPLY. - 4'-3" FROM SLIDER TO BACK DOOR — 1' -11 1/2-4 ir t m g'-6- 2' -2' m 11-0. 0­1 RffBERT E. GREGG BEGISTERED ARCHITECT P30 CHESTNUT STREET CLEARWATER, FL 33756 PHONE: (727) 796-8774 FAX* (727) 791-6942 RVOW"on: ELECTRICAL SEW02S�2002S' L Im LLI U) W Ld cf) 0 LLJ U) > cf) 1 0 V) GENERAL NOTES • EXTERIOR SKIN 090' ALUMINUM • INTERIOR SKIN M206 AL. PAINTED ViNHE ATIA NOSE . 090' ALUMINUM. * EXTERIOR FINISH STIPPLE POLYURET�fft 0 CONCRETE ISLAND, cuA.RD POSTS tz UfiLm6S NOT By CONCEPT. I f i� � rI MIN. TRAVEL BEHIND NOSE 7 0 Voptional cheque ocoaptor 3'-6 1/4" —1 r- -6'-10" EXTENDED NCR 5886 M SERIES CURRENCY DISPENSER . SHORT SLEEVE I - DATA NOT BY VIDEO CONCEPT —MAIN — SECURI — PHONE THIS UNIT EQUIPPED VATH **UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SERVICE TO MAIN PAM NOT sy cotxwTl I FINAL HOOK—UP NOT BY CONCEPT TIM PARTY; M-SWI. %VWER, CMTM & ASSDCFAT" INC 1627 SCOrrt U)NA.9 AVIL CLUAWAIIR, FL 337$6 1101 RIGHT ELEVATION --NOTE*- MUST LOCAL GROUND THIS ELECTRICAL C A UNI ONTRCTOR krpROV T IN ACCORDANCE PATH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY APPLY. - 4'-3" FROM SLIDER TO BACK DOOR — 1' -11 1/2-4 ir t m g'-6- 2' -2' m 11-0. 0­1 RffBERT E. GREGG BEGISTERED ARCHITECT P30 CHESTNUT STREET CLEARWATER, FL 33756 PHONE: (727) 796-8774 FAX* (727) 791-6942 RVOW"on: ELECTRICAL SEW02S�2002S' L Im LLI U) W Ld cf) 0 LLJ U) cf) 1 0 V) (D W co co C) Lo :3: 0 c� :2 o z< c: u E LZ J 5 r wog u "D NIP, CUnIz Ga*rmr. SOI.s- af. S. SPIGNE'R Cht,;kad Dot. 9/21/2005 Drrrtirsg No,. B -1745 WWI Of 2 6 V-6, 6 1/2' -4 11-6 " -------------. NOTCH TH AREA INSIDE BACK TO FIT CH L� _;,CCEPTOR� _0 ALL DOORS TO HAVE .125' ALUM. EXTERIOR SKIN M206 ALUM. INTERIOR SKIN - TO BE INSULATED W Rll MIN, FIBERGLASS BATT INSULATION 0 1 �o 0 AN 0 2 2008 ; 0 7 TS 3 "x 3x 1/4' COLUMNS & TS 2'x 2'x 114' 77 BEAMS - FULL PENETRATE WELDED FRAME F j7 063' AL CABINET PAINTED 5/8-0 _ V V'IHITE - TO HAVE ACCESS I , EE � �kNCHOR PANEL ON SERVICE SIDE UTILITY VALL WITH OVER-SIZED WASHER &- NUT. 5* SOR. x 3/8' THICK STEEL MOUNTING PLATE YIELDED TO STEEL TUBE FRAME UTILITY 'YA*L L DATA (1.0 CONDUIT ADA) 0 VIDEO WO CV40UIT ATM) MIN. 12' THICK CONCRETE PAD BY OTHERS 0 -0. 4 MAIN POWER (1 1/2-0, M40UM 0 SECURITY (1*,g CONDUIT) C6 &2 STL. CHANNEL (MOTION DETECTOR, KEYPAD) 0 COMMUNICA'nONS (1.0 CONDUIT) (PHONE) ANCHOR DETAIL #7 or 5* SOR. x 3/8" THK. STL, ANCHOR PLATE WELDE -- TO FLOOR FRAME PLATE TO HAVE 3/4"o HOLE TO RECEIVE 5/8-0 ANCHOR BOLT Or\ rN t, 090' ALUM. PANEL ATTACHED TO ATM CABINET SEE SHEET #1 FOR COLORS & FINISHES .Ogo' ALUMINUM EXTERIOR SKIN - SEE GRAPHIC SHEET FOR COLORS & FINISHES L PLAN — CONSTRUCTION & UTILITIES V-6. yc 2- TS 2*x 2'x 1/4- 10 7/8" TS 2' X 2- X 1/4'—. - FRONT & REAR, TOP & BOTTOM TS :rx 3-x 1/4- 8' X 8* X 1/4- STEEL GUSSET AS 1,5*xI.5*x3/I6' 1/4- TS K r"P. TOP & 807TO S 2-x 2 M _4� L7C6 . &2 ---A '-5 1/4* 2'-0' As 1.5*xI,5,x3/I6l 1*-3 1/4'2' EACH END, TOP & BOTTOM TO HAVE 6- X 1 1/2- X 1/4- THX. STL GUSSET AS 2*x 2'x 3/16' V-3 3/4' 2-­T­ ie- FULL PERATRATION TYP, 1*-4 1/4* ANCHOR PLATES TO BE 5*x 5*x 318• THICK STEEL STEEL FRAME PLATES W/ 3/4*0 HOLE FOR 5/8 0 ANCHOR BOLT ENVELOPE DISPENSER 9 ALUM. SKIN COVER X63* ALUM. 090' ALUM. BRAKEFORMED HANDLE Ft/ ROUND EDGES PAINTED To MATCH BUILDING 063' ALUM, FACE PAINTED TO MATCH BUILDING. SS RIVET 1/4' THK.STEEL COUNTER WEIGHT ( 4 REQUIRED ) INTERIOR SKIN NOTCHED AS RECTO. PVC A/C DRAIN-----N ,090' THK. BRAKErORMED ALUM. COLLECTOR BOX — THREADED COUPLING DECKING PLATE TO BE OTCHED OUT AS R16. S =:== DRAIN COLLECTOR BOX SECURED TO STEEL FRAME TUB,! %V/SELF TAPPING t WSCRE�TSAS SHOVN o . . .......... ... .. SECTION THRU A/C DRAIN COLLECTOR BOX' SCALE: 3"=1 " -0" INSTALLATION NOTES • CUT 6*- 20' ON EXTERIOR SKIN • CUT 12 1/4-x 20 1/4- ON INTERIOR SKIN • FRAME OPENING W/ .090' ALUM. CHANNELS ROBERT E. GREGG & INSERT DISPENSER FROM INSIDE REGISTERED ARCHITECT FASTEN DISPENSER TO VERTICAL 630 CHESTNUT STREET FRAME CLEARWATER, FL 33756 PHONE- (727) 796-8774 TV --NOTE-- FAX: (72-7) 791-6942 LOCAL ELECTRICAL CONTRACTOR 4- MUST GROUND THIS UNIT IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY .Ws . -CONTINUOUS DEAD OF SILICONE TO BE APPLIED TO INTERIOR OF COLLECTOR BOX DURING ASSY. THIS UNIT EQUIPPED VATH *UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SEANICS 70 MAW PARR. NOT BY cow"T. FINAL HOOK—UP NOT BY CONCEPT THM PAM, KS,0M. WVt hM CARTER & ASSWAIM WC. 1627 SOUTH UYNTLE AWE CLEWATIM. FL 35756 U2 9 r. "8 ci g tR U c; ,olo vlenL — D"ljtw- solzsmam brawn %, S. SPIGNER chuked %- mc 9/25/2005 brazing No.: B -1745 sheet Of 3 6 Lli V W Li Lli W —i 0 W cI LJJ (A 1 0 0 � 1: W T_ (.0 W 00 co — g Lo 0 < U2 9 r. "8 ci g tR U c; ,olo vlenL — D"ljtw- solzsmam brawn %, S. SPIGNER chuked %- mc 9/25/2005 brazing No.: B -1745 sheet Of 3 6 W }- i It < -r z 3 ca O w W i� ?•r c7 i M z cn s z o z � z ua w >< O i Pu z Z zW uj fi r S3 O o No ti Z ca ! I .I ::., -7 f z 's to m Iij z t3 o a :=Li � �a w 0O 2 0 r S' zz w ay Ix G) E T ZOz W S 'Ow Occ it �WF La Xrz k} 41 \;U wUL Z Ixj U tA NOTCH THIS AREA INSIDE SACK DOOR TO FIT CHEQUE ACCEPTOR. [----O 4 m IY Q ct i z `r�0 4T m Q. . w � c� j � l b �lz� 10 ice} > z rti l O O W ie d 8" C`s i ;JAN Q 2- 2008 �I f W S Q a Y V I Ld u � w vi ..r to cn Lj ff Ll Z ZD 4`a I 0- 1— (o _ 0 W'" �-f jQ bi o wfr5 [ cy O f ;s z CL t a 0 �t U --1 tC Lut C..? <� W z (otn 3 +..�, / y� 4 �S< F C� ca v O jz c, a f— 0 W z <S � (L -i rat W a - C7 iL. Z I 7 8" C`s i ;JAN Q 2- 2008 �I f W S Q a Y V I Ld u � w vi ..r to cn Lj ff 1t ZD > V i t (o _ 0 L O ry z < O f ;s z 0 Qc, jz J ( i (n AI90' ALUMINUM NOSE PANEL ATM ROUGH OPENING TO BE CUT IN FIELD 0 mm H M °NOTE** LOCAL ELECTRICAL CONTRACTOR MUST GROUND THIS UNIT IN ACCORDANCE VATH NATIONAL ELECTRICAL CODE AND ANY LOCAL. CODES THAT MAY APPLY. w w z M p U rt M ROBERT E, GREGO REGISTERED ARCHITECT 634 CHESTNUT STREET CLEARWATER, FL 33758 PHON � 7} 7) 796 -8774 FAX; 727 9i -8842 ADpED SUbz`ft ST6T'3 T. TQ?? pF CARNET. 4 N h CL W u rS w txo� �$ Ghent: oea;gn ®c 8aln n_ o, ey, S. SPIGNER Ch"ked By: p c 9/25/2405 omxing No.: B -1745 Sheet Of 4 6 Y V I Ld u w vi _0 Lj ff 1t u > V i t (o _ 0 L O ry z < 4 N h CL W u rS w txo� �$ Ghent: oea;gn ®c 8aln n_ o, ey, S. SPIGNER Ch"ked By: p c 9/25/2405 omxing No.: B -1745 Sheet Of 4 6 10" X 10" CUT YO HOLE IN TOP 03000 "fflREMOLD' JUNCTION BOX OF SLIDER AT BACK RIGHT. RACEWAY INSERT CLEAR TUBING TO ACT AS GROMMET. 15 w nio OUND COTLET IErw.-fr LOCATED SIGHT C A/C A/C A/C DRIP PAN CUTOUT CUTOUT 4' -8' mou BOT70U OF 26 2 nost CeNET AND f-3, FROM COPE-\ FRONT Cf ROSE CARKET. Rl 0) 3 A/C ORfP PAN DRAIN LINE SIGHT C4 COPE ATM 21 I X. SNTRA 21 —1 5"_ 0�0 BOARD 9 1i 6 I 19 19 MANUAL 1/_CRANK WALL D WALL A WALL B NVALL C DATA (1`0 CONDUIT ATM) VIDEO (1"0 CONDUIT ATM)­======-j NOT BY MAIN POWER (1 112"0 CONDUIT) CONCEPT- SECURITY (1.0 CONDUIT) (MOTION DETECTOR, KEYPAD) COMMUNICATIONS (1.0 CONDUIT) (PHONE) ITEM DEScitpTION MARE / MODEL / REMARKS nA WU I PANEL BOX 100 AMP LOAD CENTER 120/230/10 2 DUPLEX OLULET (2) AEO*O. STANDARD tit LISTED COMPONENT 20 120 v 3 ATM OUTLET STANDARD UL LISTED COVPONENT 20 12D V 4 0-MARK MODEL # D1512 - VIAL/CEILING HEATER GRAINGER #5ZK68 `SEND* CARRIER 5 A/C 04.111.17 S7AITDAkO Ut.LISTED COMPONENT 20 170 v 6 JUNCTION BOX. SECURITY (MOWN O-CIECTOR. KEYFAD) 7 JUNCTON BOY. COMIMUUICAWNS (PHONE) a THERMOSTAT HONEYWELL TH511OD1006 (E00031C) a JVRCWN Box, DATA (AN) JUNCTION Box 11UNC1ION1 BOX. VIDEO 12 100 cm FANS IAN 2-0 420 V 13 ___l 2' x 2' WMN0 RACEWAY (PANDUrf) 4 3- HIRE WLD OUTLET STRIP (WtLETS PrERY 6-) V-0` LONG Is MOWN DETECTOR (BY OTHERS) 16&17 SHOP LIGHT & SNITCH 1 (2) F-48-T12 FLUOR. LWP FIXTURE 20 12Q V 18 'GE ' AIR CONDITIONER MODEL #AJCHO8AC8 (OR EQUAL) T$ Alm COOLING FAN 20 KXM�LTON KT-15 PREUVATC TUBE SYSTEM (MONET W74-R) 21 1/2' THX. SWRk BOARD 22 SiNflu P1114SE OWMDM OUTLEX (2) REOD, (C14LE UM-ER ) STN+'OXRO tft. LISTE> COM:m:,=wlt 120 V 23 DEDICATED T*Wr LOCK OUTLET - IOCA WRE ) COMPONENT zo 120 v 24 MANUFACTURERS DATA PLATE LABELS 25 H010000 CE STMKEY LOCK BOX 26 TRANSFORMER 24Y (EL100318) 27 CONTACTOR 30A 1P 24V (EL10031A) SECURITY (1-0 CONDUIT) NOTES (MOTION DETECTOR, KEYPAD)— 1. CONDUIT RUNNING FROM JUNCTION BOXES (6,7,9,11) INSIDE COMMUNICATIONS (11"0 CONDUIT) OF BUILDING CAN BE REDUCED TO 3/4"0 TO MAKE EASIER INTERFACE INTO PANDUIT (PHONE, ATM) 2. 2" X 2" PLASTIC LOW VOLTAGE WIRING RACEWAY (PANDUfT) NEEDS TO CONNECT FRONT WALL TO BACK WALL (WALL "A- TO WALL "B" TO WALL "C") 3. ADD THE POINT TO POINT PEDASTAL TO THE TOP OF ALL BUILDINGS. IT WILL STAND 2 1/2- HIGH OFF BUILDING. 4. ON MODEL 200 BUILDINGS ADD MYERS HUB TO PHOTOCELL. THIS WILL ALLOW PHOTOCELL TO BE REPLACED WITHOUT DAMAGING ROOF MEMBRANE. 5. LABEL OUTLETS (5, 23, 22, 4) BY VOLTAGE AND AMPERAGE IN (POINT TO POINT) MONEY MOVER AREA. I 6 —10 21/32- 3' EXHAUST TUBE —S' CARRIER TUBE CUT 3'0 HOLE IN TOP OF SLIDER AT BACK RIGHT. - INSERT CLEAR TUBING TO ACT AS GROMMET. WALL "A! D wen: -ON/OFF- &ITCH I �> ISAMP FUSES -MOVABLE ACCESS SUER -OPRENE RUBBER 'i HAMILTON 'HT-15- PNEUMATIC TUBE SYSTEM ELECTRICAL REOVIRZMENTS: 115 VOLTS so HZ 30 AMP EA. ENO 0 v JAN 0 2 ?008 gip. �6 OUT 4 1/2- @ @ AL MONEY-MOVER) STATIONARY —SHELF of c4 .... ............... TOP OF FLOOR =1_1 WALL E (SIDE A) CONCEALED A/C DRAIN TO EXIT BOTTOM. OUTSIDE EDGE OF EXTERIOR SKIN (t V 2- (OPTIONAL MONEY - HOVER) WALL "C' INTERIOR UTILITY Im WALL V ROOM WALL - uj - ROBERT E. GREGO REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33756 PHONE: (727) 796-8774 FAX: (727) 791-6942 ••NOTE•. LOCAL ELECTRICAL CONTRACTOR MUST GROUND THIS UNIT IN ACCORDANCE VATH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY APPLY. THIS UNIT EQUIPPED VATH **UL'* LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SERMCE TO MAIN PANa, NOT By CONCO.T. FINAL HOOK-UP NOT BY CONCEPT -WIFZ PARTY. HILBORK, VXRNER CARTIER & ASSWATES, RIO. 1 1627 SOUTH MYRTLE ALE. WlAllwkup, FL 33756 Rt - C m4u-xl TMv.w 1aTAT TO xulw." nz- 0�wl.o MANO HINGED V w/XCRYUC WNC `SEND* CARRIER _SvATCH D wen: -ON/OFF- &ITCH I �> ISAMP FUSES -MOVABLE ACCESS SUER -OPRENE RUBBER 'i HAMILTON 'HT-15- PNEUMATIC TUBE SYSTEM ELECTRICAL REOVIRZMENTS: 115 VOLTS so HZ 30 AMP EA. ENO 0 v JAN 0 2 ?008 gip. �6 OUT 4 1/2- @ @ AL MONEY-MOVER) STATIONARY —SHELF of c4 .... ............... TOP OF FLOOR =1_1 WALL E (SIDE A) CONCEALED A/C DRAIN TO EXIT BOTTOM. OUTSIDE EDGE OF EXTERIOR SKIN (t V 2- (OPTIONAL MONEY - HOVER) WALL "C' INTERIOR UTILITY Im WALL V ROOM WALL - uj - ROBERT E. GREGO REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33756 PHONE: (727) 796-8774 FAX: (727) 791-6942 ••NOTE•. LOCAL ELECTRICAL CONTRACTOR MUST GROUND THIS UNIT IN ACCORDANCE VATH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY APPLY. THIS UNIT EQUIPPED VATH **UL'* LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SERMCE TO MAIN PANa, NOT By CONCO.T. FINAL HOOK-UP NOT BY CONCEPT -WIFZ PARTY. HILBORK, VXRNER CARTIER & ASSWATES, RIO. 1 1627 SOUTH MYRTLE ALE. WlAllwkup, FL 33756 Rt - C m4u-xl TMv.w 1aTAT TO xulw." nz- 0�wl.o ISLAND LENGTH VARIES --- E Q U A' EQUAL 14`0 CONCRETE FILLED BOLLARDS NOT BY CONCEPT DATA (1-0 CONDUIT — ATM) VOW (1-0 CONDUIT ATM) 0 0 NOT By MAIN POWER (1 1/2*0 CONDUIT) COUCEPT - SECURITY (1-0 CONDUIT) (WOnOl'q DETECTOR, KEYPAD) CaMUNICATIONS (1.0 CONDUIT) (0 (PHONE) 0 3"' rI LCONCRETE ISLAND —3*-7 LCL NOT BY CONCEPT 3 1/2" 5'— 9 TRAFFIC FLOW UTILITY PLAN VIEW EDGE I DRIVEWAY—i �Rp . T„;' _ "V JAN 0 2 2008 Ic Iq v ER. GK� '\rl CAP PAINTED TO MATCH 2" WIDE REFLECTIVE TAPE *ro BE WHITE 4"0 STEEL PIPE BOLLARD "REFER TO OWNERS'REPRESENT- ATIVE FOR COLOR) CONCRETE ISLAND/ CURB--I BOLLARD DETAIL (NOT BY CONCEPT) � .NOTE- OCAL ELECTRICAL CONTRACTOR MUST GROUND THIS UNIT IN ACCORDANCE VATH NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES THAT MAY APPLY. ROBERT E. GREGG REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33756 PHONE: '�)277 ! 796-8774 AX. , (72 ) 91 F —6942 THIS UNIT EQUIPPED MTH "UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED ELECTRICAL SERVICE TO MAIN PMEL Nor BY 000UPL FINAL HOOK—UP NOT BYCONCEPT M90 PARTY' RUOR14, V,flU2ER, CARTER & ASSMATES. ino. 1627 SOUTH MRE AVIL alnmus' FL 33738 . ............ __ CL W o U E u ZD cr'ant: cws€q"r. SW.mwn: Dma,, af, S. SPIGNER Chacktd fh: wc 9/25/2005 Ofa*ing ua't B-1745 Shoat Of 6 6 Lli W w cf) —i 0 Ld (f) W (f) 1 0 0 > T V) (0 00 r) Lo 0 0� u f_ z < CL W o U E u ZD cr'ant: cws€q"r. SW.mwn: Dma,, af, S. SPIGNER Chacktd fh: wc 9/25/2005 Ofa*ing ua't B-1745 Shoat Of 6 6 T4! H, IN iA TC Of Hil TO OF Hil, STANLEY ZINC Pi.A`tEO CHAIN DOORSTOP ATTACHED TO INSIDE OF ENTRY DOOR VATH COUNTERSUNK #IOXI/2- SCREWS WARNER HERSEY DOOR SCOPE DSIO00 ROCKWOOD FLUSH PULL HANDLE SCHLAGE DEAD BOLT SC160P 626 EVEREST SINGLE CYLINDER iL 0 Y I, 0 0 0 Z < I, 0 Z W 0 Z r7 I ENTRY DOOR 61 LB& BACK DOOR 60 LBS. ENTRY DOOR FRAME 6' X 6' .090' THK. ALUMINUM PANEL POP RIVETED TO INSIDE OF DOOR, (3) BOLT OOKS BARREL VrESTWARO 4- BARREL L (2) WESTWARD 4 3/4' DOOR PULLS SCREWED TO PANELS THIS UNIT EQUIPPED t'ATH "UL"' LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED M-EC'MCAL SERVIl,Mr TO UAW PAKM WT SY OMOEPT, FINAL HOOK-UP NOT BY CONCEPT IK" PARTY. K'49CW, MRt4ER. CAAM & AssOaATm W_ 1827 SOUK WMnf *Vt 0""ATM It =W I RII INSULATION INSIDE OF D 040' THK, STUCCO ALUMINUI. iNTERtOR SKIN POP RIVETED A85-6 EVERY 6 PATH A 5/32" X 1/2" LONG F POP RIVET SHEAR STRENGTH POP RIVET TENSILE STRENGTH .090' THK. ALUMINUM EXTERI SKIN ATTACHED TO FRAME W 11' ACRYLIC ADHESIVE. 1 1/2" X 1 1/2' X 1/8' THK ALUMINUM TUBING FRAME PART NAME I MATERIAL I ENTRY DOOR SIDE VIEW 31/8 4 2 CHANNEL PIN STEEL 5 2 EF0_DY_Yl`NC r- 6 2 LONG ROLLER NYLON 1/4 IF EXC--EDED OCCIR 7 2 _SPACER _NYLON k;A'Y' NOT OPEN SHORT 2 ROLLER NYLON 8 LINK NYLON JAN 0 2 2008 7 4 1 19/32 3 1-13/32 @NOT SHVhN, 4 6/6 7%32 M& KOLE 'Mm 13/32 Era 02' C'S NX x __j 1/16 CAP 9132 —9/16 HINGE CLOSED HINGE OPEN ENTRY DOOR SIDE VIEW is RII INSULATION INSIDE OF DC .040' THK. STUCCO ALUMINUM INTERIOR SKIN POP RIVETED AB5-6 EVERY 6' WITH A 5/32' X 1/2' LONG PO POP RIVET SHEAR STRENGTH 3( POP RIVET TENSILE STRENGTH 4 090" THK. ALUMINUM EXTERIOR SKIN ATTACHED TO FRAME PATH ACRYLIC ADHESIVE. 1 1/2- X 1 1/2- X 1/8- THK. ALUMINUM TUBING FRAME BACK DOOR SIDE VIEW 18 SOSS HINGE DETAIL FOR ALL DOORS ROBERT E. GREGO REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33756 PHONE- (72 796-8774 FAX: {727j 7)91-6942 u O O c: u amp zg O'D 4 c4imb D.algImr solas m Drown or. S. SPIGNER Ch.tkdd gy Date. 12-7-07 Drawirq No.. B-1745 snatt Of 1 2 3 — 5 1 FRAI,4�4 r- t1 JAN 0 2 2008 is RII INSULATION INSIDE OF DC .040' THK. STUCCO ALUMINUM INTERIOR SKIN POP RIVETED AB5-6 EVERY 6' WITH A 5/32' X 1/2' LONG PO POP RIVET SHEAR STRENGTH 3( POP RIVET TENSILE STRENGTH 4 090" THK. ALUMINUM EXTERIOR SKIN ATTACHED TO FRAME PATH ACRYLIC ADHESIVE. 1 1/2- X 1 1/2- X 1/8- THK. ALUMINUM TUBING FRAME BACK DOOR SIDE VIEW 18 SOSS HINGE DETAIL FOR ALL DOORS ROBERT E. GREGO REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARWATER, FL 33756 PHONE- (72 796-8774 FAX: {727j 7)91-6942 u O O c: u amp zg O'D 4 c4imb D.algImr solas m Drown or. S. SPIGNER Ch.tkdd gy Date. 12-7-07 Drawirq No.. B-1745 snatt Of 1 2 0 5/32"0 RIVETS 0.040" THK. STUCCO ALUf,,IINVM //—INTERIOR SKIN USE ACRYLIC ADHESIVE - TYP. 1--0.090" THK. ALUMINUM EXTERIOR SKIN — UP TO 40" DOOR CROSS SECTION NOT TO SCALE 2 3/4" USE ACRYLIC ADHESIVE — TYP. 100% COVERAGE BOTH SIDES OF Z BAR. 0-090" ALUMINUM EXTERIOR SKIN 0.090' ALUMINUM HORIZONTAL SUPPORT WALL PANEL SKIN HORIZONTAL SUPPORTS NOT TO SCALE D DOOR LOCK DETAIL NOT TO SCALE INTERNAL HORIZONTAL SUPPORTS FULLY COVERS UP TO RADIUS START. 0.080 ALUM. 1-4' ANGLE VERTICAL SUPPORTS 7.5" MAX, TYP. — r-Ir- A P i f l - 5/32"0 RIVETS -1 ONSTRUCT IL. N. n qj WALL C ------- III i (D I WALL 8 tl WALL Q 11 WALL A r�� f R, 0 JAN 0 2 co- .090" THK. ,ALUMINUM SKIN . IV I , TIT op- REGISTERED ARCHITECT 630 CHESTNUT STREET CLEARViATER, FL 33756 PHONE- �M) 796-8774 FAX' {72 7) 791-6942 THIS U NI T EQUIPPED WITH *UL" LISTED ELECTRICAL COMPONENTS 120/230 VOLTS REQUIRED QU ELECTRICAL SERIACE TO MAIN NOT ' , PANEL NOT By CONCEPT, FINIAL HOOK—UP NOT BY CONCEPT ............. THIRD PARTY: HILSORN, WERNER, CARTER & ASSOCIATES, INC, 1627 SOUTH MYRTLE AVE CLEARWATER. Fl 33756 141, 11 • allull Shoot of