Loading...
HomeMy WebLinkAboutARB201500067 Plan - Approved 2015-11-10SOLAR BAN °60 Solar Control Low -E Glass Fabrication and Availability Solarbafr 60 glass is available' PPG Certified exclusively through the FABRICATOR® NETWORK PPG Certified Fabricator" Network. PPG Certified Fabricators can meet tight construction deadlines and accelerate the delivery of replacement glass before, during and after construction. Solarban® 60 glass is manufactured using the sputter- coating process and is available for annealed, heat - strengthened and tempered applications. e SolarbaM 60 Klass is iust one of manv ecological Ecological Solutions from PPG Tm. For Solutions f-, Pro more information, or to obtain samples of this product, call 888 - PPG -IDEA (774- 4332), or visit www. ppgideascapes.com. PPG is the first U.S. float glass manufacturer to have its products recognized by the Cradle to Cradle Certifiedcm program, and it offers more C2C- certified architectural glasses than any other float glass manufacturer. PPG /deaScapes® Integrated products, people and services to inspire your design and color vision. Additional Resources Solarban® 60 Glass Performance - Commercial Insulating Glass Unit Comparisons Using 1/4" (6mm) Glass MnMMTMM ,. Z177171A ! r Transmittance Glass Type Ultra. Total Visible Solar violet Energy �gy r Reflectance U -Value (Imperial) Winter Summer European Shading Night- Day- U -Value Coefficient time time Solar Heat Gain Coefficient Light to Solar Gain (LSG) Visible light % Total Solar Energy SOLARBAN 60 (2) Clear + Clear 18 70 34 11 28 0.29 0.27 1.6 0.45 0.39 1.79 SOLARBAN 60 (2) STARPHIRE" 24 74 39 11 41 0.29 0.27 1.6 0.48 0.41 1.80 SOLARBAN 60 (2) ATLANTICA + Clear 5 53 20 8 7 0.29 0.27 1.6 0.32 0.27 1.96 SOLARBAN 60 (2) AZURIA+ Clear 13 54 21 8 6 0.29 0.27 1.6 0.32 0.28 1.93 SOLARBAN 60 (2) OPTIGRAY+ Clear 10 50 23 8 14 0.29 0.27 1.5 0.35 0.30 1.67 SOLARBAN 60 (2) PACIFICA + Clear 5 34 15 6 6 0.29 0.27 1.6 0.26 0.22 1.55 SOLARBAN 60 (2) SOLARBLUE + Clear 10 45 21 7 12 0.29 0.27 1.6 0.33 0.28 1.61 SOLARBAN 60 (2) SOLARBRONZE + Clear 8 42 21 7 15 0.29 0.27 1.6 0.32 0.28 1.50 SOLARBAN 60 (2) SOLARGRAY + Clear 8 35 18 6 12 0.29 0.27 1.6 0.29 0.25 1.40 SOLARBAN 60 (2) SOLEXIA + Clear 10 j 61 25 9 10 0.29 0.27 1.6 0.37 0.32 1.91 ATLANTICA® + SOLARBAN 60 (3) Clear 5 53 20 9 7 0.29 0.27 1.6 0.36 0.31 1.71 AZURIA® + SOLARBAN 60 (3) Clear 13 54 21 9 7 0.29 0.27 1.6 0.36 0.31 1.74 GRAYLITE® I I + SOLARBAN 60 (3) Clear 1 7 4 4 5 0.29 0.27 1.6 0.14 0.13 0.54 OPTIGRAI° + SOLARBAN 60 (3) Clear 10 50 23 8 15 0.29 0.27 1.5 0.40 0.35 1.43 PACIFICA' + SOL031)e 0 (3) Clear 5 34 15 6 7 0.29 0.27 1.6 0.29 0.25 1.36 SOLARBLUE® + SN 60 (3) Clear 10 45 21 7 13 0.29 0.27 1.6 0.38 0.33 1.36 SOLARBRONZE® BAN 60 (3) Clear 8 42 21 7 16 0.29 0.27 1.6 0.37 0.32 1.31 SOLARGRAY® + N 60 (3) Clear 8 35 18 7 13 0.29 0.27 1.6 0.33 0.29 1.21 SOLEXIA`� + SOL (3) Clear 10 61 25 10 10 0.29 0.27 1.6 0.42 0.37 1.65 ' VISTACOOL (2) ALow -E 11 42 16 20 11 0.29 0.27 1.6 0.30 0.26 1.62 VISTACOOL (2) P Low -E 4 26 12 11 9 0.29 0.27 1.6 0.25 0.21 1.24 SOLARCOOL (2) A Low -E 4 21 8 19 10 0.29 0.27 1.6 0.19 0.17 1.24 SOLARCOOL (2) + Low -E 2 13 6 10 8 0.29 0.27 1.6 0.17 0.15 0.87 SOLARCOOL (2) SOLARBLUE+ Law -E 3 17 9 14 15 0.29 0.27 1.6 0.21 0.18 0.94 SOLARCOOL (2) SOLARBRONZE+ Low -E 2 17 9 14 18 0.29 0.27 1.6 0.21 0.18 0.94 SOLARCOOL (2) SOLARGRAY+ Low -E 2 14 8 11 14 0.29 0.27 1.6 0.20 0.17 0.82 SOLARCOOL (2) SOLEXIA+ Low -E 1 3 1 24 = 24 15 0297 0.27 1 1.6 0.22 0.19 1.26 * Data based on using STARPHIRP glass for both interior and exterior lites. All performance data calculated using LBNL Window 6.3 software, except European 1.1-value, which is calculated using WinDat version 3.0.1 software. For detailed information on the methodologies used to calculate the aesthetic and performance values in this table, please visit www.ppgideascapes.com or request our Architectural Glass Catalog. © 2014 PPG Industries, Inc. All rights reserved. Atlantica, Azuria, Azurlfte, Graylite, /deaScapes, Oceans of Color, Optiblue, Optigray, Pacifica, Solarban, Solarblue, Solarbronze, Solarcool, Solargray, Solex, Solexia, Starphire, Sungate, Vistacool, the PPG logo and the PPG Certified Fabricator Network and the PPG Certified Programs are registered trademarks of PPG Industries Ohio, Inc. Cradle to Cradle Certified is a certification mark licensed by the Cradle to Cradle Products Innovation Institute. Ecological Solutions from PPG is a trademark of PPG Industries Ohio, Inc. 5 Printed in U.S.A. cradletocradle 7071 09/1410M";:': Glass • Coatings • Paint 4 i f r 7� ����� ��,�' {r iel.�Ll. M 44t != LUMINAIRE MOUNTING HEIGHT A.F.G. HUBBELL IS NOT RESPONSIBLE FOR THE PERFORMANCE wmlwo xnww. Sy w ­1 Qty D.—pt,. Arnnp.m.nl Lum. Watt Lun.lum.n. LLF BW patlnp —® A 3 CLIfi KA DIUtlbeA LIS) SINGLE 141 13036 1.000 B]-111-G3 B 1 CL 0L­J -BC (HUEbd ltp) SINGLE 1436 1138 1.000 BO -U1G1 —® C 1 CL110LiK -0SC(­IA Lo) SINGLE 100.3 9658 1.000 BDU1G3 CC2 2 TWIN 1403 9656 000 BO UiG3 ® OB 4 5611- 15AT20L8010M SINGLE 19.9 1130 JAW N.A OC 1 V 41,39 BAR t30 SINGLE 48.9 3108 1.000 B3 -UOGO ® WP 1 DSMI LED 10C 100040K T M MT SINGLE 40 3085 1.000 B1 -UO-0i POLE SPEC FOR CIMARRON: SINGLE FIXTURE SSS- XX- XX- X -A2 -XX TWIN FIXTURE 180 DEGREE APART SSS- XX- XX- X -C2 -XX POLE AND WALL MOUNTED FIXTURES -DARK BRONZE y0 i� S GRAPHIC SCALE IN FEET 0 10 20 40 \ �6 L 16 L L L L a L L L L L L L L L L L / \ S, t, L ao L m ao a, a. to t. a. as to L a, a, o, t, io L 10 L L 't. L L t. / t. L t. ` t, t, t, t, t. t. L L t, t. t, t, t, t, t, L L L L L L L t. L L .. .. a. / • a J� " " %, t, 3, L —t� -5� �, -1,— —t- —C —t- —t, ,. —t- a, L� _,tom— t. L I L t6 t. t. t. b. L t. L 16 t' /j t, t' t, ..* t, --t, - -L t, t. t i. a, L L t, L L t t, L t. L t. L L t. L U /v „ L L L t. L L . t. t. b. L L L MH: MH:12 L L MH: , t, t, L 5 L . A. M ' 12 f �MF: 20 L t^ L t. t. L L t >/ i /b�/ t, S. L L L t, P L t. A L L L L '. 1: 20 CIIS pharmacy • L L L t, . t' 11,945 SF. TYPE B ;. t. t. .s 57 PARKS PROVIDED P MH: 12 L t. F.F.E. 497.25 MH: 12 / I I L S., 3, ., ., .. N„ ,. .. S, f. S, III / A MH: 20 I I I I I m- t. * 'So°1Atr L S. L i'R L L L 5, L ,D t. L r C S, -t. t, L t. L L L L ,. S. L L '20 to S EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMPTHAT EMITS 3,000 OR L L I L t, t, L \ \. t, \L \ �4 ., t, t. �1Ly�x -L L L ., t, L L t. 1, t. O L ., MORE INITIAL LUMENS SHALL BEAFULL CUTOFF LUMINAIRE AND SHALL BE 1� � ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING ,,, L b� a, t, ., t. „ m t, „ — ., t, to ,. 'SA'u. i. RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. THE SPILLOVER \ 'C2 L { a ��.'x C2y OF LIGHTING FROM LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN � MH: 20 i RESIDENTIAL OR RURAL AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE \ ., „ i, ,. b. t. t,to t, t, L L L t. „ L '.. L L L :, L L "'S? _ L L L L L L t. M HALF FOOTCANDLE. - -- - -_•_ -- — --- - - - - -- —J --- - - - - -- L L L FOR PRICING CONTACT t, o. t. t, Ir — — v --7— s - 'r- — s� �b, t. NESCO L t. L L t. t, L L L t, t, L t, t, t, t, t, L L t. L L L L L t. t, t, t. a: t, L L L L t. L t. 40 Hudson Rd Canton, MA 02021 L L L L L L a. t, a, t. a, t. t, t, L t. L L t. L L L L L L L t, t, t, t, t, t, t, t, t L t. Tel: 781 - 828 -9494 Fax. 781 -575 -1398 t. L t. L L m t. L L L L a. L . L L .. L L L '6 ., L t. L L t, a, t, L t 1. t. t. L E -Mall., CVSplans@_nescoweb.com L L L L L L L L t, L L L L t. L t. L L L L L L a. L L t.. a. L to L L t. t. L L L L L L t. L L t. L L L L L L t. to L 1. L L L L L L L L t. L L L L L L L L L NOT A CONSTRUCTION DOCUMENT — FOR DESIGN PURPOSES ONLY gm pharmacy® NORTHERN 1,945 8F RW CHAMFER DRIVE —THRU STORE NLUUE 10746 SEMINOLE TRAIL k RIO ROAD (NWC) ALBEMARLE COUNTY, VA. PRO,ECT TM NEW UC E DEAL T M PPS CS PROJECT NUMBER 86047 F11 Kimley> »Horn CONSULTANT- KIMLEY —HORN AND ASSOCIATES, INC. 1700 WILLOW LAWN DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER THE REBKEE COMPANY 15871 CITY VIEW DRIVE, SUITE 300 MIDLOTHIAN, VA 23113 TEL: (804) 419 -0740 FAX: (804) 419 -0759 m REVISIONS: ■ poi DRANING BY: POLE SPEC FOR CIMARRON: SINGLE FIXTURE SSS- XX- XX- X -A2 -XX TWIN FIXTURE 180 DEGREE APART SSS- XX- XX- X -C2 -XX POLE AND WALL MOUNTED FIXTURES -DARK BRONZE y0 i� S GRAPHIC SCALE IN FEET 0 10 20 40 \ �6 L 16 L L L L a L L L L L L L L L L L / \ S, t, L ao L m ao a, a. to t. a. as to L a, a, o, t, io L 10 L L 't. L L t. / t. L t. ` t, t, t, t, t. t. L L t, t. t, t, t, t, t, L L L L L L L t. L L .. .. a. / • a J� " " %, t, 3, L —t� -5� �, -1,— —t- —C —t- —t, ,. —t- a, L� _,tom— t. L I L t6 t. t. t. b. L t. L 16 t' /j t, t' t, ..* t, --t, - -L t, t. t i. a, L L t, L L t t, L t. L t. L L t. L U /v „ L L L t. L L . t. t. b. L L L MH: MH:12 L L MH: , t, t, L 5 L . A. M ' 12 f �MF: 20 L t^ L t. t. L L t >/ i /b�/ t, S. L L L t, P L t. A L L L L '. 1: 20 CIIS pharmacy • L L L t, . t' 11,945 SF. TYPE B ;. t. t. .s 57 PARKS PROVIDED P MH: 12 L t. F.F.E. 497.25 MH: 12 / I I L S., 3, ., ., .. N„ ,. .. S, f. S, III / A MH: 20 I I I I I m- t. * 'So°1Atr L S. L i'R L L L 5, L ,D t. L r C S, -t. t, L t. L L L L ,. S. L L '20 to S EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMPTHAT EMITS 3,000 OR L L I L t, t, L \ \. t, \L \ �4 ., t, t. �1Ly�x -L L L ., t, L L t. 1, t. O L ., MORE INITIAL LUMENS SHALL BEAFULL CUTOFF LUMINAIRE AND SHALL BE 1� � ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING ,,, L b� a, t, ., t. „ m t, „ — ., t, to ,. 'SA'u. i. RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. THE SPILLOVER \ 'C2 L { a ��.'x C2y OF LIGHTING FROM LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN � MH: 20 i RESIDENTIAL OR RURAL AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE \ ., „ i, ,. b. t. t,to t, t, L L L t. „ L '.. L L L :, L L "'S? _ L L L L L L t. M HALF FOOTCANDLE. - -- - -_•_ -- — --- - - - - -- —J --- - - - - -- L L L FOR PRICING CONTACT t, o. t. t, Ir — — v --7— s - 'r- — s� �b, t. NESCO L t. L L t. t, L L L t, t, L t, t, t, t, t, L L t. L L L L L t. t, t, t. a: t, L L L L t. L t. 40 Hudson Rd Canton, MA 02021 L L L L L L a. t, a, t. a, t. t, t, L t. L L t. L L L L L L L t, t, t, t, t, t, t, t, t L t. Tel: 781 - 828 -9494 Fax. 781 -575 -1398 t. L t. L L m t. L L L L a. L . L L .. L L L '6 ., L t. L L t, a, t, L t 1. t. t. L E -Mall., CVSplans@_nescoweb.com L L L L L L L L t, L L L L t. L t. L L L L L L a. L L t.. a. L to L L t. t. L L L L L L t. L L t. L L L L L L t. to L 1. L L L L L L L L t. L L L L L L L L L NOT A CONSTRUCTION DOCUMENT — FOR DESIGN PURPOSES ONLY gm pharmacy® NORTHERN 1,945 8F RW CHAMFER DRIVE —THRU STORE NLUUE 10746 SEMINOLE TRAIL k RIO ROAD (NWC) ALBEMARLE COUNTY, VA. PRO,ECT TM NEW UC E DEAL T M PPS CS PROJECT NUMBER 86047 F11 Kimley> »Horn CONSULTANT- KIMLEY —HORN AND ASSOCIATES, INC. 1700 WILLOW LAWN DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER THE REBKEE COMPANY 15871 CITY VIEW DRIVE, SUITE 300 MIDLOTHIAN, VA 23113 TEL: (804) 419 -0740 FAX: (804) 419 -0759 m REVISIONS: DRANING BY: RRP DATE: MARCH 7, 2016 JOB NUMBER: 113001348 TITLE: LIGHTING PLAN SHEET NUMBER: CL -101 COMMENTS: GENERAL PLANTING NOTES: THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, ETC. NECESSARY TO COMPLETE ALL PLANTING AS SHOWN ON THE PLANTING PLANS, AS SPECIFIED HEREIN OR IN SUPPLEMENTAL SPECIFICATIONS, AND /OR AS REQUIRED BY JOB CONDITIONS. THE WORK IN GENERAL INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: (1) SOIL PREPARATION; (2) PROVIDING TOPSOIL AND ALL SOIL AMENDMENTS; (3) EXCAVATION OF PLANT PITS; (4) PROVIDING ALL PLANT MATERIAL AND MULCH AS INDICATED ON PLANS; (5) FERTILIZING; (6) STAKING; (7) CHEMICAL APPLICATION; (8) MAINTENANCE AND GUARANTEE; (9) ALL OTHER ITEMS NECESSARY TO MAKE WORK COMPLETE. THE PLANTING CONTRACTOR IS RESPONSIBLE FOR COORDINATING WORK WITH THE OTHER CONTRACTORS. THIS PLAN DOES NOT GUARANTEE THE EXISTENCE OR NON - EXISTENCE OF ANY UTILITIES. PRIOR TO ANY CONSTRUCTION, EXCAVATION, OR ROTO - TILLING THE CONTRACTOR SHALL ASSUME THE RESPONSIBILITY OF VERIFYING THE LOCATIONS OF ALL UTILITIES, ABOVE AND /OR BELOW GROUND, PUBLIC AND /OR PRIVATE THAT MAY EXIST AND CROSS THROUGH THE AREAS OF CONSTRUCTION. (1) SOIL PREPARATION (1.1) BECAUSE OF SOIL COMPACTION DURING CONSTRUCTION, ALL PLANTING AREAS SHALL BE ROTOTILLED TO A DEPTH AS SHOWN IN DETAILS OR AS SPECIFIED IN WRITTEN SPECIFICATIONS. A PLANTING AREA IS ANY AREA IN WHICH NEW PLANTING OCCURS. EXCAVATE THE ENTIRE AREA BOUNDED BY WALKS, WALLS, FENCES, ETC. REMOVE SPOIL MATERIAL AS DIRECTED BY OWNER OR THE OWNER'S REPRESENTATIVE. (1.2) EXCAVATED SOIL SHOULD BE USED AS BACKFILL MATERIAL IN ORDER TO ELIMINATE OR MINIMIZE THE OCCURRENCE OF HYDROLOGIC DISCONTINUITIES, AND /OR SOIL INTERFACE PROBLEMS COMMON TO PLANTING BEDS CONTAINING SOILS OF DIFFERENT TEXTURE. WHERE THE TEXTURE OF THE EXISTING SOIL IS UNDESIRABLE FOR THE PLANT SPECIES BEING PLANTED (i.e. HEAVY CLAY, PURE SAND) AND WHERE THE pH OF THE EXISTING SOIL IS SUITABLE FOR THE SPECIES BEING PLANTED, THE SOIL SHALL BE BLENDED 66% EXISTING SOIL WITH 33% AMENDED SOIL. (1.3) WHERE IT IS DETERMINED THAT THE EXISTING SOIL EXCAVATED IS TOTALLY UNSUITABLE FOR USE AS BACKFILL MATERIAL BECAUSE OF IMPROPER pH OR THE PRESENCE OF DEBRIS OR OTHER DELETERIOUS MATTER, THE BACKFILL MATERIAL SHALL BE 100% AMENDED SOIL MIXTURE AS DESCRIBED BELOW WITH THE ADDITION OF 1/2 PART SAND. AMENDED SOIL: PLANTING SOIL FOR AMENDING BACKFILL SHALL BE 100 % TOPSOIL WITH AMENDMENTS ADDED ACCORDING TO THE RECOMMENDATIONS OF THE SOILS TEST REPORT TO BRING THE pH VALUE OF THE PLANTING BACKFILL MIXTURE WITHIN THE RANGES DESCRIBED BELOW. THE TOPSOIL AND AMENDMENTS SHALL BE MIXED AT AN ON -SITE LOCATION. PLANTING SOIL SHALL NOT BE MIXED AT INDIVIDUAL PLANT LOCATIONS. (2) TOPSOIL AND ALL SOIL AMENDMENTS (2.1) NECESSARY QUANTITIES OF TOPSOIL SHALL BE SUPPLIED BY THE CONTRACTOR AND APPROVED BY THE OWNER OR HIS REPRESENTATIVE. THE CONTRACTOR SHALL APPLY TOPSOIL ONLY AFTER SECURING SOIL TEST (V.P.I.), APPLYING RECOMMENDED TREATMENT THEREOF, AND SUBMITTING FOR APPROVAL. (2.2) ON-SITE TOPSOIL MEETING THE CONDITIONS FOR THESE NOTES MAY BE USED, OR IF INSUFFICIENT QUANTITIES ARE AVAILABLE, OUTSIDE TOPSOIL MEETING THE FOLLOWING CRITERIA SHALL BE PROVIDED. (2.3) ON-SITE TOPSOIL SHALL BE STOCKPILED TOPSOIL THAT HAS BEEN SALVAGED IN ACCORDANCE WITH SECTION 303.04(A) OF THE V.D.O.T. SPECIFICATIONS. IT SHALL BE FREE FROM REFUSE, OR ANY MATERIAL TOXIC TO PLANT GROWTH, AND REASONABLY FREE FROM SUBSOIL, STUMPS, ROOTS, BRUSH, STONES, CLAY, LUMPS, OR SIMILAR OBJECTS LARGER THAN 3" IN THEIR GREATEST DIMENSION. (2.4) OFF -SITE TOPSOIL, IF NEEDED, SHALL BE TOPSOIL FURNISHED FROM SOURCES OUTSIDE THE PROJECT LIMITS AND SHALL BE THE ORIGINAL TOP LAYER OF A SOIL PROFILE FORMED UNDER NATURAL CONDITIONS, TECHNICALLY DEFINED AS THE "A" HORIZON BY THE SOIL SOCIETY OF AMERICA. IT SHALL CONSIST OF NATURAL, FRIABLE, LOAMY SOIL WITHOUT ADMIXTURES OF SUBSOIL. OR OTHER FOREIGN MATERIALS, AND SHALL BE REASONABLY FREE FROM STUMPS, ROOTS, HARD LUMPS, STIFF CLAY, STONE, NOXIOUS WEEDS, BRUSH, OR OTHER LITTER. IT SHALL HAVE DEMONSTRATED BY EVIDENCE OF HEALTHY VEGETATION GROWING, OR HAVING GROWN ON IT PRIOR TO STRIPPING, THAT IT IS REASONABLY WELL DRAINED AND DOES NOT CONTAIN SUBSTANCES TOXIC TO PLANTS. (2.4.1) "A" HORIZON: "A" HORIZONS SHALL BE MINERAL HORIZONS CONSISTING OF (1) HORIZONS OR ORGANIC MATTER ACCUMULATION FORMED OR FORMING AT OR ADJACENT TO THE SURFACE; (2) HORIZONS THAT HAVE LOST CLAY, IRON, OR ALUMINUM, WITH RESULTANT CONCENTRATIONS OF QUARTZ OR OTHER RESISTANT MINERALS OF SAND OR SILT SIZE; OR (3) HORIZONS DOMINATED BY 1 OR 2 ABOVE BUT TRANSITIONAL TO AN UNDERLYING B OR C. (2.4.2) "A" HORIZON SUBDIVISIONS: Al HORIZONS SHALL BE MINERAL HORIZONS, FORMED OR FORMING AT OR ADJACENT TO THE SURFACE, IN WHICH THE FEATURE EMPHASIZE D IS AN A CCUMULATION OF HUMIDIFIED ORGANIC MATTER INTIMATELY ASSOCIATED WITH THE MINERAL FRACTION. THE SOIL IS A DARK OR DARKER THAN UNDERLYING HORIZONS BECAUSE OF THE PRESENCE OF ORGANIC MATTER. THE ORGANIC MATERIAL IS ASSUMED TO BE DERIVED FROM PLANT AND ANIMAL REMAINS DEPOSITED ON THE SURFACE OF THE SOIL OR DEPOSITED WITHIN THE HORIZON WITHOUT APPRECIABLE TRANSLOCATION. A2 HORIZONS SHALL BE MINERAL HORIZONS IN WHICH THE FEATURE EMPHASIZED IS LOSS OF CLAY, IRON OR ALUMINUM, WITH RESULTANT CONCENTRATION OF QUARTZ OR OTHER RESISTANT MINERALS IN SAND AND SILT SIZES. (2.4.3) "A" HORIZON TOPSOIL CONTENT: "A" HORIZON TOPSOIL SHALL BE IN ACCORDANCE WITH THE FOLLOWING MATERIALS BY PERCENTAGE OF VOLUME: SILT 42 -58% SAND 15-20% CLAY 15-20% ORGANIC MATERIAL 12 -18% (2.5) TOPSOIL SHALL HAVE A pH IN THE RANGE OF 6.0 TO 7.0 PRIOR TO MIXING WITH AMENDMENTS. IF THE pH IS NOT WITHIN THIS RANGE, THE pH SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE OR A DIFFERENT SOURCE OF SUPPLY SHALL BE SELECTED. TOPSOIL SHALL BE SUBJECT TO INSPECTION BY THE OWNER OR THE OWNER'S REPRESENTATIVE AT THE SOURCE OF SUPPLY AND IMMEDIATELY PRIOR TO USE IN THE PLANTING OPERATIONS. US PLANTS SHALL HAVE A H VALUE BETWEEN 6.0 AND 7.0 R DECIDUOUS , 2.6 PLANTING SOIL AFTER AMENDING FO P VALUE BETWEEN 5.0 AND 6.0. A NT SHALL HAVE A H U PLANTS AND FOR EVERGREEN OR SEMI-EVERGREEN P REPRESENTATIVE SAMPLE FROM THE EXCAVATED SOIL SHALL BE FIELD TESTED FOR pH UTILIZING A RELIABLE SOIL pH METER OR SOIL pH TEST KIT. THE pH VALUE OF THE NATURAL SOIL BACKFILL MIXTURE MAY BE AMENDED BY ADDING LIMESTONE OR ALUMINUM SULFATE AS NEEDED. (3) EXCAVATION OF PLANT PITS (3.1) PRIOR TO EXCAVATION OF TREE PITS, AN AREA EQUAL TO TWO TIMES THE DIAMETER OF THE ROOT BALL SHALL BE ROT0.TILLED TO A DEPTH EQUAL TO THE DEPTH OF THE ROOT BALL. U (3.2) IN CONTINUOUS SHRUB AND GROUND COVER BEDS, THE ROTO TILLED PERIMETER SHOULD EXTEND TO A DISTANCE OF ONE FOOT BEYOND THE DIAMETER OF A SINGLE ROOTBALL. THE BED SHALL BE TILLED TO A DEPTH EQUAL TO THE ROOT BALL DEPTH PLUS 6 ". (3.3) TREE PITS FOR WELL DRAINED SOILS SHALL BE DUG SO THAT THE BOTTOM OF THE ROOT BALL WILL REST ON UNDISTURBED SOIL AND THE TOP OF THE ROOT BALL WILL BE FLUSH WITH FINISH GRADE. IN POORLY DRAINED SOILS THE TREE PIT SHALL BE DUG SO THAT THE ROOT BALL RESTS ON UNDISTURBED SOIL AND THE TOP OF THE ROOT BALL IS V ABOVE FINISH GRADE. PLANT PIT WALLS SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION. (3.4)SHRUB BEDS SHALL BE EXCAVATED TO 6" BELOW THE ROOT BALL OF THE SHRUB. (3.5) ALL AIR POCKETS SHALL BE REMOVED FROM PLANT PIT UPON BACK FILLING WITH PLANTING SOIL BY FILLING APPROXIMATELY 1/2 TO 2/3 OF THE PIT WITH PLANTING BACKFILL MATERIAL, TAMPING BACKFILL MATERIAL AND THEN WATERING TO ENSURE SETTLEMENT OF THE MATERIAL. BACKFILL MATERIAL SHALL THEN BE PLACED WITHIN THE REMAINING CAVITIES OF THE PLANT PIT, TAMPING AND WATERED AGAIN TO ENSURE SETTLEMENT OF THE BACKFILL MATERIAL. UNDER NO CIRCUMSTANCES SHALL ANY SOIL OR BACKFILL MATERIAL BE APPLIED ABOVE THE ROOT BALL OF THE PLANTS. (3.6) GROUND COVERS SHALL BE PLANTED IN BEDS HAVING A MINIMUM DEPTH OF 4" BELOW THE PROPOSED ROOT DEPTH. PLANTS SHALL BE EVENLY SPACED AND SET TO MAINTAIN THE ORIGINAL GROWING DEPTH WHILE ALLOWING FOR A 2" TOP DRESSING OF MULCH. (4) PLANT MATERIAL AND MULCH (4.1) THE NAMES OF PLANTS REQUIRED UNDER THIS CONTRACT CONFORM TO THOSE GIVEN IN L.H. BAILEY'S HORTUS THIRD, 1976 EDITION. NAMES OF VARIETIES NOT INCLUDED THEREIN CONFORM GENERALLY WITH NAMES ACCEPTED IN THE NURSERY TRADE. ALL PLANTS SHALL HAVE A HABIT OF GROWTH THAT IS NORMAL FOR THEIR SPECIES AND THEY SHALL BE SOUND, HEALTHY AND VIGOROUS, WITH WELL DEVELOPED ROOT SYSTEMS. ALL PLANT MATERIAL SHALL BE FREE FROM INSECT PESTS, PLANT DISEASES, AND INJURIES. ALL PLANTS SHALL EQUAL OR EXCEED THE MEASUREMENTS SPECIFIED IN THE PLANT LIST, WHICH ARE MINIMUM ACCEPTABLE SIZES. TREES SHALL HAVE SINGLE TRUNKS EXCEPT AS NOTED. ALL SHRUBS SHALL BE HEALTHY, VIGOROUS, AND OF GOOD COLOR. ONLY DAMAGED OR BROKEN BRANCHES OF PLANT MATERIAL MAY BE PRUNED AND ANY NECESSARY PRUNING SHALL BE DONE AT THE TIME OF PLANTING. HOWEVER, UNDER NO CIRCUMSTANCES SHALL THE CENTRAL LEADER OF A PLANT BE PRUNED. (4.2) ALL TAGS, STRINGS OR ANY OTHER MATERIAL ATTACHED TO THE PLANTS SHALL BE REMOVED AT THE TIME OF THE PLANTING. BALLING AND BURLAPPING OF PLANTS SHALL FOLLOW THE CODE OF STANDARDS CURRENTLY RECOMMENDED BY THE AMERICAN STANDARD FOR NURSERY STOCK. (4.3) SUBSTITUTIONS WILL BE PERMITTED ONLY UPON SUBMISSION OF PROOF THAT ANY PLANT IS NOT OBTAINABLE. ALL SUBSTITUTIONS MUST BE AUTHORIZED BY THE OWNER OR THE OWNER'S REPRESENTATIVE IN WRITING PROVIDING FOR USE OF THE NEAREST EQUIVALENT OBTAINABLE SIZE OR VARIETY OF PLANT HAVING THE SAME ESSENTIAL CHARACTERISTICS AS THE ORIGINAL VARIETY WITH AN EQUITABLE ADJUSTMENT OF CONTRACT PRICE. (4.4) BALLED AND BURLAPPED PLANTS (B &B) SHALL BE DUG WITH FIRM, NATURAL BALLS OF EARTH OF SUFFICIENT DIAMETER AND DEPTH TO ENCOMPASS THE FIBROUS AND FEEDING ROOT SYSTEM NECESSARY FOR FULL RECOVERY OF THE PLANT. BALLS SHALL BE FIRMLY WRAPPED WITH BURLAP OR SIMILAR MATERIAL AND BOUND WITH TWINE OR CORD. BURLAP SHALL NOT BE PULLED OUT FROM UNDER BALLS DURING PLANTING OPERATIONS. B &B PLANTS WHICH CANNOT BE PLANTED IMMEDIATELY ON DELIVERY SHALL BE COVERED WITH MOIST SOIL, MULCH, OR OTHER MATERIAL TO PROVIDE PROTECTION FROM DRYING WINDS AND SUN. (4.5) PLANTS NOTED "CONTAINER" ON THE PLANT LIST MUST BE CONTAINER GROWN WITH WELL ESTABLISHED ROOT SYSTEMS. LOOSE CONTAINERIZED PLANT MATERIAL WILL NOT BE ACCEPTED. ALL PLANTS INJURED AND PLANTS WITH ROOT BALLS BROKEN DURING TRANSPORT OR PLANTING OPERATIONS WILL BE REJECTED. BARE - ROOTED PLANTS (BR) SHALL BE PLANTED OR HEELED -IN IMMEDIATELY UPON DELIVERY. ALL PLANTS SHALL BE WATERED AS NECESSARY UNTIL PLANTED. (4.6) NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON THE PLAN EXCEPT WHERE OBSTRUCTIONS BELOW GROUND ARE ENCOUNTERED OR WHERE CHANGES HAVE BEEN MADE IN THE PROPOSED CONSTRUCTION. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. REASONABLE CARE SHALL BE EXERCISED TO HAVE PLANTING PITS DUG AND SOIL PREPARED PRIOR TO MOVING PLANTS TO THEIR RESPECTIVE LOCATIONS TO ENSURE THAT THEY WILL NOT BE UNNECESSARILY EXPOSED TO DRYING OR PHYSICAL DAMAGE. (4.7) A LIST OF PLANTS, INCLUDING SIZES, QUANTITIES AND OTHER REQUIREMENTS, IS SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE QUANTITIES AS SHOWN ON THE DRAWINGS. IF DISCREPANCIES OCCUR IN THE QUANTITIES SHOWN, THE PLANTING PLANS SHALL GOVERN. (4.8) THE PLANTING CONTRACTOR WILL BE NOTIFIED BY THE GENERAL CONTRACTOR WHEN OTHER DIVISIONS OF THE WORK HAVE PROGRESSED SUFFICIENTLY TO COMMENCE WORK ON THE PLANTING OPERATION. THEREAFTER, PLANTING OPERATIONS SHALL BE CONDUCTED UNDER FAVORABLE WEATHER CONDITIONS DURING THE NEXT SEASON OR SEASONS WHICH ARE NORMAL FOR SUCH WORK. REMOVAL OF ROCK OR OTHER UNDERGROUND OBSTRUCTIONS, RELOCATIONS TO AVOID OBSTRUCTIONS, AND PROVISION OF DRAINAGE FOR PLANTING AREAS SHALL BE DONE ONLY AS APPROVED BY THE OWNER OR THE OWNER'S REPRESENTATIVE. (4.9) ALL PLANTS SHALL BE PLANTED UPRIGHT AND FACED TO GIVE THE BEST APPEARANCE OR RELATIONSHIP TO ADJACENT STRUCTURES. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS SHALL BE CUTOFF CLEANLY. PLANTS WITH CIRCLING ROOTS SHALL NOT BE ACCEPTED. BURLAP TWINE AND OTHER FASTENING MATERIAL SHALL BE CUT AND PUSHED TO THE BOTTOM OF THE PLANT PIT PRIOR TO BACKFILL MATERIAL BEING PLACED. THE PLANT SHALL NOT BE ROCKED BACK AND FOURTH TO ENTIRELY REMOVE THE WRAPPING MATERIAL NOR SHALL ANY OTHER PRACTICE BE PERFORMED WHICH COULD CAUSE THE ROOT BALL TO BREAK APART. WHEN WIRE BASKETS ARE USED ON THE ROOT BALL OF PLANTS THE WIRE SHALL BE REMOVED TO AT LEAST 12" BELOW THE TOP OF THE ROOT BALL. (4.10) AT THE TIME OF PLANTING, AND AS MANY TIMES LATER AS SEASONAL CONDITIONS REQUIRE, EACH PLANT AND THE SOIL AROUND IT SHALL BE THOROUGHLY WATERED. CARE SHOULD BE EXERCISED WHEN WATERING TO AVOID FLOODING OF PLANTS AND BEDS, DISPLACEMENT OF MULCH MATERIAL AND EROSION OF SOIL. AVOID USE OF HIGH PRESSURE HOSES. THE CONTRACTOR SHALL MAKE" AT HIS EXPENSE, WHATEVER ARRANGEMENTS MAY BE NECESSARY TO ENSURE AN ADEQUATE SUPPLY OF WATER TO MEET THE NEEDS OF THIS CONTRACT DURING INSTALLATION. THE CONTRACTOR SHALL ALSO FURNISH ALL NECESSARY HOSE, EQUIPMENT ATTACHMENTS AND ACCESSORIES FOR THE ADEQUATE WATERING OF PLANTED AREAS AS MAY IBE REQUIRED UNTIL ACCEPTANCE BY THE OWNER OR THE OWNER'S REPRESENTATIVE. (4.11) MULCH SHALL BE CLEAN, GROUND OR SHREDDED BARK OR HARDWOOD MULCH. IN PLANTING AREAS WHERE SLOPES EXCEED 3:1 AND AT DRAINAGE DISPERSIION POINTS OR ALONG NATURAL WATER WAYS WHERE CONCENTRATIONS OF SURFACE WATER EMPTY FROM CULVERTS OR PAVED DITCHES, HEAVY JUTE MESH SHALL BE INSTALLED, SHREDDED HARDWOOD OR BARK MULCH SHALL HAWE BEEN COMPOSTED FOR AT LEAST TWO MONTHS PRIOR TO APPLICATION. FRESHLY GROUND MULCH WILL NOT BE ,ACCEPTED. FINELY GROUND MULCH WHICH INHIBITS DRAINAGE, ENCOURAGES WEED GROWTH OR BECOMES WATERLOGGED WILL NOT BE ACCEPTED. MULCH SHALL BE COMPOSED OF SIMILAR SIZED FRAGMENTS AND SHALL NOT CONTAIN STICKS, CONES, LEAVES, UNSHREDDED PIECES, OR OTHER DELETERIOUS MATTER. ALL AZALEA AND CAMELLIA PLANTING BEDS SHALL HAVE V OF PINE STRAW MULCH UNDER 3" OF SHREDDED HARDWOOD MULCH. (4.12) ALL PLANTS SHALL BE MULCHED IMMEDIATELY AFTER PLANTING. GROUND COVERS SHALL BE MULCHED WITH A 3" LAYER OF DOUBLE SHREDDED HARDWOOD MULCH. ALL OTHER PLANTING BEDS, SHRUBS AND TREE PLANTINGS SHALL BE MULCHED WITH A 4" MINIMUM LAYER OF7 MULCH. THIS MULCH SHALL ENTIRELY COVER THE AREA OF THE PLANTING PIT, BED, OR EARTH BERM AROUND EACH PLANT WITH THE EXCEPTION OF THE AREA IMMEDIATELY ADJACENT TO THE PLANT TRUNK OR TRUNKS. THE AREA IMMEDIATELY ADJACENT TO THE PLANT TRUNK OR TRUNKS SHALL BE LEFT FREE OF ANY MULCH. (5) FERTILIZING (5.1) THE FERTILIZER SHOULD BE A DRY !SLOW RELEASE FORM OF FERTILIZER. IT SHOULD CONTAIN AT LEAST 25-50% WATER INSOLUBLE NITROGEN. THE FERTILIZER SELECTED SHOULD ALSO HAVE A LOW ADJUSTED SALT INDEX TO PREVENT BURNING. THE N -P -K RATIO SHOULD NO'T EXCEED 3-1 -2 UNLESS THE SOIL TEST REVEALS THAT ADDITIONAL LEVELS OF P AND K ARE NECESSARY. (5.2) FOR DECIDUOUS TREES, USE OSMOOCOTE (18 -6 -12) AT THE RATE EQUIVALENT T04 LBS ACTUAL N /1000 SQ FT OF ROOT ZONE AREA/YEAR. FOR EVERGREEN TRIEES USE 2 LBS ACTUAL N /1000 SQ FT OF ROOT ZONE AREA/YEAR. (5.3) MIX THE FERTILIZER INTO THE BACIKFILL SOIL OF THE TREE PITS. FOR SHRUB BEDS, MIX THE FERTILIZER INTO THE AREA THAT HAS BEEN ROTO- TILLED FOR THE PLANTS. (5.4) THE FERTILIZER RATE FOR CONTINIUOUS GROUND COVER AND SHRUB BEDS SHOULD BE DERIVED BY CALCULATING THE ENTIRE ROOT ZONE AREA. THE ROOT ZONE AREA IS FOUND BY MEASURING THE AREA CONTAINING THE MULTIPLE PLANT ROOTS. USE OSMOCOTE (18- 6-121) AT A RATE EQUIVALENT TO 2 LBS OF N /1000 SQ FT OF ROOT ZONE AREA. THE FERTILIZER SHOULD BE EVENLY DISTRIBUTED WITHIN THE SHRUB BED SOIL. (5.5) ALWAYS BE SURE THAT ADEQUATE! MOISTURE IS AVAILABLE WHEN FERTILIZING SO THAT THE FERTILIZER WILL BE DISSOLVED INTO THE SOIL SOLUTION FOR ROOT UPTAKE AND TO AVOID BURNING THE ROOTS. (6) STAKING (6.1) ALL TREES SHALL BE STAKED ACCORDING TO THE TYPICAL DETAILS PROVIDED. (6.2) THREE STAKES SHALL BE REQUIRED PER LARGE AND MEDIUM TREES. SMALL DECIDUOUS TREES LARGER THAN 1" CALIPER AND EVERGREEN TREES SHALL ONLY BE REQUIRED TO BE STAKED WITH 2 STAKES. TREES 1" CALIPER AND SMALLER SHALL ONLY BE REQUIRED TO BE STAKED WITH ONE STAKE. THE STAKES SHALL BE DRIVEN IN A RADIAL PATTERN FOR LARGE, MEDIUM AND SMALL DECIDUOUS TREES. STAKES FOR EVERGREEN TREES SHALL BE PROVIDED ON EACH SIDE OF THE TREE 180 DEGREES APART. STAKES SHALL BE DRIVEN VERTICALLY INTO THE GROUND OUTSIDE THE EDGE OF THE ROOTBALL TO A DEPTH OF 21/2' TO VON OPPOSITE SIDES OF THE TREE IN SUCH A MANNER AS NOT TO INJURE THE ROOT BALL OR ROOTS. STAKES FOR SUPPORTING TREES SHALL BE 1.5"X 1.5" SQUARE OR ROUND, BY 8'. THE STAKES SHALL BE SOUND WOOD TREATED WITH A SUITABLE WOOD PRESERVATIVE. TIES SHALL BE ARBORTIE (OR EQUAL) SIZED APPROPRIATELY PER MANUFACTURES RECOMMENDATIONS FOR THE SIZE OF TREE SPECIFIED. ARBORTIE (OR EQUAL) SHALL BE NAILED TO WOODEN STAKES, OR TIED AROUND AT' STAKE WITH A ROLLING HITCH. NO ANCHORS OR NAILS SHALL BE USED ON THE TREE ITSELF. USE ARBORKNOT DETAILS TO SECURE: ARBORTIE (OR EQUAL) AROUND NEWLY PLANTED TREE. IF APPROPRIATELY TIED, ARBORTIE SHALL PROVIDE A SECURE, GIRDLE FREE ATTACHMENT TO THE TREE, WHICH WILL EXPAND AS THE TREE GROWS. NO ANCHORS OR NAILS SHALL BE USED ON THE TREE ITSELF. SECURE LONG END OF ARBORTIE 9OS; EQUAL) TO THE EYE OF THE STAKE OR ANCHOR. ADD TENSION TO THE ARBORTIE (OR EQUAL) BY DRIVING THE STAKE OR AINCHOR INTO THE GROUND OUTSIDE OF THE PLANTING HOLE AT A 45 DEGREE ANGLE TO THE TREE TRUNK. WHEN DRIVING THE STAKE OR ANCHOR INTO THE GROUND, ENSURE EYE OPENING IS NOT BURIED. FINAL STAKE PLACEMENT SHALL ENSURE EYE OPENING IS EVEN TO SOIL LEVEL. STAKES OR ANCHORS SHALL BE EVENILY SPACED AROUND THE TREE. (6.3) WOODEN STAKES AND WIRE TIES SHALL BE REMOVED AFTER ONE YEAR (7) CHEMICAL APPLICATION (7.1) ALL PESTICIDES SHALL BE PRODUCTS OF RECOGNIZED COMMERCIAL MANUFACTURERS, AND SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE, AND LOCAL PESTICIDE LAWS. PESTICIDES SHALL BE APPLIED WITH CALIBRATED EQUIPMENT ACCORDING TO EPA LABEL RESTRICTIONS AND REGULATIONS BY A CERTIFIED APPLICATOR. ANY DAMAGE INCURRED TO THE SITE, ADJACENT PROPERTIES, OR APPLICATOR DURING PESTICIDE APPLICATIONS WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. (7.2) PESTICIDES SHOULD BE USED ONLY WHEN NECESSARY TO TREAT AN OUTBREAK OF A HARMFUL PEST OR DISEASE PROBLEM. THE OWNER OR THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED 24 HOURS PRIOR TO THE APPLICATION OF ANY PESTICIDE. (8) MAINTENANCE AND GUARANTEE (8.1) THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING HIS WORK FOR THE PERIOD OF TWO YEAR AFTER SUBSTANTIAL COMPLETION AND ACCEPTANCE BY THE OWNER OR THE OWNER'S REPRESENTATIVE. MAINTENANCE SHALL INCLUDE WATERING, WEEDING, CULTIVATING, MULCHING, REMOVAL OF DEAD MATERIALS, RESETTING OF PLANTS TO RIGHT POSITIO PROPER GRADES O R UP NNS RESTORATION OF EARTH BERMS AND ND OTHER NECESSARY OPERATIONS. ADEQUATE PROTECTION FOR LAWN ARE A S AGAINST TRESPASSING DURING PLANTING OPERATIONS AND AGAINST DAMAGE OF ANY KIND SHALL BE PROVIDED. NOTFHING IN THESE NOTES IS INTENDED TO RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO REPAIR EXISTING LAWN AREAS DAMAGED BY WORKMEN ENGAGED IN THE COMPLETION OF THIS PROJECT. (8.2) INSPECTION OF THE WORK TO DETERMINE COMPLETION OF THE CONTRACT EXCLUSIVE OF THE POSSIBLE REPLACEMENT OF PLANTINGS, WILL BE MADE BY THE OWNER ORTHE OWNER'S REPRESENTATIVE AT THE CONCLUSION OF THE INSTALLATION PERIOD UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION. REQUEST SHALL BE SUBMITTED BY CONTRACTOR AT LEAST THIRTY DAYS PRIOR TO THE ANTICIPATED DATE FOR INSPECTION. AFTER INSPECTION, THE CONTRACTOR WILL BE NOTIFIED IN WRITING CO 71 G BY THE OWNER R OR THE W O NER'S REPRESENTATIVE OF ACCEPTANCE OF THE WORK, EXCLUSIVE OF THE POSSIBLE REPLACEMENT OF PLANTS SUBJECT TO GUARANTEE; OR, IF THERE ARE ANY DEFICIENCIES, THE CONTRACTOR WILL BE NOTIFIED OF THE REQUIREMENTS NECESSARY FOR COMPLETION OF THE WORK. PLANTINGS SHALL NOT BE CONSIDERED, ACCEPTED UNTIL ALL DEFICIENCIES HAVE BEEN CORRECTED AND APPROVED IN WRITING. (8.3) NURSERY STOCK SHALL BE FULLY GUARANTEED FOR TWO FULL YEARS. ALL PLANTS THAT FAIL TO MAKE NEW GROWTH FROM A DORMANT CONDITION OR THAT DIE DURING THE FIRST YEAR AFTER PLANTING SHALL BE REPLACED. ALL REPLACEMENTS SHALL CONFORM WITH THE ORIGINAL SPECIFICATIONS AS TO SIZE AND TYPE. ALL COSTS OF REPLACEMENTS SHALL BE BORNE BY THE CONTRACTOR. (9) ALL OTHER ITEMS NECESSARY TO MAKE WORK COMPLETE (9.1) ANY PLANT MATERIAL NOT PLANTED SHALL BE REMOVED FROM THE SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL UNUSED RUBIBISH AND DEBRIS FROM THE SITE UPON COMPLETION OF HIS WORK. (10) PERMANENT SEEDING (SHALL ONLY' APPLY TO DISTURBED AREAS NOT INDICATED TO RECEIVE SOD. (10.1) TOPSOILING: WHERE TOPSOIL IS REQUIRED ON ADVERSE SOIL CONDITIONS, A MINIMUM OF FOUR INCHES OF TOPSOIL SHOULD BE USED. THE TOPSOIL SHOULD CONTAIN A MINIMUM OF 35% FINE GRAINED MATERIAL (SILT AND CLAY AND 1.5 %+ ORGANIC MATTER). (10.2) LIME AND FERTILIZER: A. LIME - APPLY GROUND LIMESTONE OR B. LIME - APPLY PULVERIZED AGRICULTURAL LIMESTONE OR EQUIVALENT AT THE RATE OF 2 TONS PRE ACRE. C. FERTILIZER - 500 POUNDS PER ACIRE OF 10 -20 -10 FERTILIZER OR EQUIVALENT. IF SOILS ARE UNIFORM, IT IS DESIRABLE TO HAVE LIME AND FERTILIZER RECOMMENDATIONS BASED ON SOIL TESTS. THE LIME AND FERTILIZER SHOULD BE DISKED OR WORKED INTO A GOOD SEEDBED TO A DEPTH OF THREE TO FOUR INCHES. (10.3) SPRING AND FALL SEEDING: SEED ONE OF THE FOLLOWING VARIETIES AT THE SPECIFIED RATES PER ACRE FOR TURF AREAS SEEDED IN THE SPRING OR FALL (SEE SPECIFIED SEEDING DATES BELOW): TYPE OF GRASS SEEDING RATE SEEDING DATE TALL FESCUE (1) 5 - 7 LBSA000 SQ). FT. SPRING SEEDING: MARCH, TO EARLY APRIL. FALL SEEDING: AUGUST 1 TO NOVEMBER 1 NOTE: PREFERRED FESCUE SEEDING DATES ARE FROM AUGUST 1 TO NOVEMBER 1. SPRING SEEDING DATES WOULD BE FROM FEBRUARY 28, TO MAY 15. (2) ONLY FESCUE SEED THAT HAS PROVEN SUCCESSFUL IN THE PROJECT VICINITY SHALL BE SELECTED FROM THE FOLLOWING VARIETIES OR FROM )VARIETIES AS RECOMMENDED IN THE 2014 -2015 VIRGINIA TURFGRASS VARIETY RECOMMENDATIONS AVAILABLE FROM VIRGINIA COOPERATIVE EXTENSION, VIRGINIA TECH, VIRGINIA STATE UNIVERSITY: 2ND MILLENNIUM, AVENGER, BILTMORE, BINGO, BLACKWATCH, BRAVO, COCHISE 11(3), COCHISE 111, CONSTITUTION, COYOTE 11, CROSSFIRE 11(3,4), DAVINCI(3), DAYTONVA(3), ENDEAVOR(3), FALCON IV, FIDELITY, FORTE, GOOD- EN(3,4), GRANDE(4), GRANDE II, GREENKEEPER WAF, GUARDIAN 21, HOUNDOG 5, HUNTER, INFERNO, JUSTICE, MAGELLAN, MASTERPIECE, MATADOR(3), MATADOR GT(3), ONYX(3,4)), PADRE, PICASSO(3), PENN 1901, RAPTOR, REBEL EXEDA, REGIMENT II, REMBRANDT(3), SOUTHERN CHOICE 11(3)x, SR 8250(3), TAOS, TARHEEL, TARHEEL 11, TEMPEST, TITANIUM, TOMBSTONE, TURBO, ULTIMATE(3), WATCHDOG, AND WOLFPA(CK. SODDING NOTES: (1) VEGETATIVELY PROPAGATED FESCUE SOD IS THE PREFERRED LAWN GRASS. ONLY VARIETIES THAT HAVE PROVEN SUCCESSFUL IN THE PROJECT VICINITY SHALL BE SELECTED FRONN THE FOLLOWING OR FROM VARIETIES AS RECOMMENDED IN THE 2014 -2015 VIRGINIA TURFGiRASS VARIETY RECOMMENDATIONS AVAILABLE FROM VIRGINIA COOPERATIVE EXTENSION, VIRGINIA TECH, VIRGINIA STATE UNIVERSITY AND SHALL BE A BLEND OF SEED THAT WILL BE TOLERANT OF SHADE TO FULL SUN CONDITIONS. 2ND MILLENNIUM, AVENGER, BILTMORE, BINGO, BLACKWATCH, BRAVO, COCHISE 11, COCIHISE 111, CONSTITUTION, COYOTE 11, CROSSFIRE 11, DAVINCI, DAYTONA, ENDEAVOR, FALCON IV, FIDELITY, FORTE, GOOD -EN, GRANDE, GRANDE 11, GREENKEEPER WAF, GUARDIAN 21, HOUNDOG 5, HUNTER, INFERNO, JUSTICE, MAGELLAN, MASTERPIECE, MATADOR, MATADOR GT, ONYX, PADRE, PICASSO, [PENN 1901, RAPTOR, REBEL EXEDA, REGIMENT 11, REMBRANDT, SOUTHERN CHOICE II, SR 8250, TAOS, TARHEEL, TARHEEL II, TEMPEST, TITANIUM, TOMBSTONE, TURBO, ULTIMATE, WATCHDOG, AND WOILFPACK. (2) THE CONTRACTOR SHALL SOD ALL AREAS THAT ARE NOT PAVED OR PLANTED AS [DESIGNATED ON THE DRAWINGS WITHIN THE CONTRACT LIMITS, UNLESS SPECIFICALLY NOTED OTHERWIISE. (3) THE SOD SHALL BE CERTIFIED TO MEET LOCAL STATE PLANT BOARD SPECIFICATIONS, ABSOLUTELY TRUE TO VARIETAL TYPE, AND FREE FROM WEEDS, FUNGUS, INSECTS ANC) DISEASE OF ANY KIND. (4) SOD PANELS SHALL BE LAID TIGHTLY TOGETHER SO AS TO MAKE A SOLID SODDED) LAWN AREA. SOD SHALL BE LAID UNIFORMLY AGAINST THE EDGES OF ALL CURBS AND OTHER HARDSCAPE ELEMENTS, PAVED AND PLANTED AREAS. IMMEDIATELY FOLLOWING SOD LAYING, THE LAWN AREAS SHALL BE ROLLED WITH A LAWN ROLLER CUSTOMARILY USED FOR SUCH PURPOSES, AND THEN THOROUGHLY IRRIGATED. IF, IN THE OPINION OF THE OWNER, TOP- DRESSING IS NECESSARY AFTER ROLLING TO FILL THE VOIDS BETWEEN THE SOD PANELS AND TO EVEN OUT INCONSISTENCIES IN THE SOD, CLEAN SAND, AS APPROVED BY THE OWNER'S REPRESENTATIVE, SHALL BE UNIFORMLY SPREAD OVER THE ENTIRE SURFACE OF THE SOD AND THOROUGHLY WATERED IN. FERTILIZE INSTALLED SOD AS ALLOWED BY PROPERTY'S JURISDICTIONAL AUTHORITY. (5) DURING DELIVERY, PRIOR TO, AND DURING THE PLANTING OF THE LAWN AREAS, TIHE SOD PANELS SHALL AT ALL TIMES BE PROTECTED FROM EXCESSIVE DRYING AND UNNECESSARY EXPOSURE OF THE ROOTS TO THE SUN. ALL SOD SHALL BE STACKED SO AS NOT TO BE DAMAGED BY SWEATING OR EXCESSIVE HEAT AND MOISTURE. (6) LAWN MAINTENANCE (7) WITHIN THE CONTRACT LIMITS, THE CONTRACTOR SHALL PRODUCE A DENSE, WELL ESTABLISHED LAWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND RE- SODDING OF ALL ERODED, SUNKEN OR BARE SPOTS (LARGER THAN 12 "X12 ") UNTIL CERTIFICATION OF ACCEPTABILIITY BY THE OWNER OR OWNER'S REPRESENTATIVE. REPAIRED SODDING SHALL BE ACCOMPLISHED AS IN THE ORIGINAL WORK (INCLUDING REGRADING IF NECESSARY). (8) CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING AND MAINTAINING SOD /LAWN [FOR A PERIOD OF TWO YEARS UNTIL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE. //" /,CAR DOOR �i PARKING ISLAND, SIDE DETAIL PARKING ISLAND, NOSE -IN DETAIL '%",--J ' 1 1. INSTALL CONTINUOUS MULCH BED ADJACENT TO PARKING SPACES AS SHOWN., MULCH SHALL BE MIN. 3" DEEP. NO POP -UP IRRIGATION HEADS SHALL BE LOCATED WITHIN 24" OF A PARKING SPACE ON ANY SIDE 2. CURB OR PARKING LOT EDGE Parking Space ace Curb Plantin _ SEC11ON NTS SHOVEL EDGE DIFFERENT PLANTING TREATMENTS GENERAL NOTES A. PROVIDE SMOOTH CONTINUOUS EDGE AS SHOWN. DIG EDGE WITH COMMON SPADE OR STRAIGHT BLADE SHOVEL. 5" MIN. Shovel Edge Detail SECTION NTS (10.4) MULCH A. MULCH WITH ANY OF THE MATERIALS LISTED BELOW AND AT THE RATE INDICATED, SPREADING SHOULD BE UNIFOREXISTING GRAD AND AT A RATE THAT PERMITS NO) MORE THAN 25 -50% OF THE GROUND SHOWING THROUGH THE MULCH. (DASHES B. MULCHING IS SPECIFICALLY REQUIIRED ON ALL SOILS EXCEEDING 25% SLOPE. 1. STRAW -1 TO 2 TONS/ACRE DEPENDING ON SEASON AND METHOD OF APPLICATION. 2. WOOD FIBER MATERIALS - 1,0)00 LBS. PER ACRE. (10.5) MAINTENANCE \� A. IRRIGATION - IF SOIL MOISTURE IS DEFICIENT, SUPPLY NEW SEEDINGS AND PLANTINGS WITH ADEQUATE WATER FOR PLANT GROWTH UNTIL THEY ARE (FIRMLY ESTABLISHED. B. REPAIR - INSPECT ALL AREAS FOR PLANTING FAILURES AND MAKE NECESSARY REPAIRS, REPLACEMENTS, AND RESEEDING WITH THE PLANTING SEASON IF POSSIBLE. C. LIME AND FERTILIZER - SHALL BE /APPLIED UNDER REGULAR PROGRAM THAT IS BASED ON SOIL FERTILITY TESTS AND ON THE USE AND GENERAL AIPPEARANCE OF THE VEGETATIVE COVER DURING SUBSEQUENT GROWING SEASONS. SEEDING NOTES: ALL AREAS WITHIN THE LIMITS OF CONSTFRUCTION THATARE NOT OTHERWISE COVERED BY BUILDINGS, PAVEMENT, SIDEWALKS, WOODED AREAS AND PLANTING / MULCHED BEDS OR OTHERWISE CALLED OUT AS SOD LAWN AREAS SHALL BE SEEDED PER THE PERMANENT SEEDING SPECIFICATIONS IN THE PRECEDING PARAGRAPH. SEEDED AREAS WILL ONLY BE ACCEPTEID AFTER DISTURBED AREAS ARE COMPLETELY COVERED IN A DENSE LAWN CONSISTING OF THE SPECIFIED PERMANENT GRASS. • ALL SHRUBS AND GROUNDCOVERS SHALL BE PLUMB VERTICALLY, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. Shrub /Groundcover Planting on a Slope SECTION ARBORTIE (OR EQUAL) NAILED TO STAKE Tree Tie Detail SECTION (TREES UNDER 3.5" CAL OR 14' IN HEIGHT) NTS ENDS ARBORTIE EQUAL) BACK. RE TO STAKE WITH NLVANIZED ROOFING OR USA A KNOT. GENERAL LANDSCAPE NOTES: A. CONTRACTOR SHALL REVIEW ALL DRAWINGS, SPECIFICATIONS, PERMITS, AND REGULATORY REQUIREMENTS PRIOR TO COMMENCEMENT OF WORK. B. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED LANDSCAPING AND IRRIGATION PERMITS. C. CONTRACTOR SHALL VERIFY ALL EXISTING AND PROPOSED SITE ELEMENTS AND NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. SURVEY DATA OF EXISTING CONDITIONS WAS PROVIDED BY OTHERS. D. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. AT LEAST 48 HOURS PRIOR TO ANY DEMOLITION, GRADING, OR CONSTRUCTION ACTIVITY THE CONTRACTOR SHALL NOTIFY "MISS UTILITY" OF VIRGINIA FOR PROPER IDENTIFICATION OF EXISTING UTILITIES WITHIN THE PROJECT SITE. THE CONTRACTOR IS RESPONSIBLE FOR FOR REPAIRING ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC. WHICH OCCUR AS A RESULT OF THE LANDSCAPE CONSTRUCTION. E. FINAL LOCATION OF ALL PLANTINGS SHALL BE DETERMINED IN THE FIELD BY THE OWNER'S CHOSEN REPRESENTATIVE. F. SUBSTITUTIONS AND /OR MODIFICATIONS TO PLANTING LAYOUT, PLANT MATERIALS, ETC. SHALL NOT BE MADE WITHOUT THE WRITTEN CONSENT OF THE OWNERS REPRESENTATIVE. AND APPROVAL BY ALBERMARLE COUNTY. G. CONTRACTOR SHALL INSTALL ALL PLANT MATERIALS AS SHOWN IN THE DETAILS, AND AS INDICATED IN THE LANDSCAPE SPECIFICATIONS. H. THE PLANTING OF TREES SHALL BE DONE IN ACCORDANCE WITH THE STANDARDIZED LANDSCAPE SPECIFICATIONS JOINTLY ADOPTED BY THE VIRGINIA NURSERYMEN'S ASSOCIATION, THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS AND THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS. 1. SIZE AND GRADING STANDARDS OF PLANT MATERIALS SHALL CONFORM TO THE LATEST ADDITION OF ANSI Z60.1, AMERICAN STANDARD FOR NURSERY STOCK, BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. J. ALL PLANT MATERIALS SHALL BE NURSERY GROWN STOCK AND SHALL BE FREE OF ANY DEFORMITIES, DISEASES, OR INSECT DAMAGE. ANY MATERIALS WITH DAMAGED OR DISFIGURED/ CROOKED LEADERS, BARK ABRASIONS, SUNSCALD, INSECT DAMAGE, ETC., ARE NOT ACCEPTABLE AND WILL BE REJECTED. K. TREES NOT EXHIBITING A CENTRAL LEADER WILL BE REJECTED UNLESS CALLED OUT IN THE PLANT LIST AS MULTI -STEM. L. ALL AREAS ON PLANS NOT INDICATED T R PAVEMENT R HARD APE O RECEIVE SOD PLANTING O SC WHICH ARE DISTURBED BY CONSTRUCT ED PER T PLANTING ION ACTIVITIES SHALL BE SEED R HE PLANT NOTES, UNLESS OTHERWISE DIRECTED BY THE LANDSCAPE ARCHITECT. SEE PLANTING NOTES THIS SHEET. M. PLANT MATERIALS SHOWN ON PLANS ARE A GRAPHIC REPRESENTATION ONLY. CONTRACTOR SHALL PERFORM ALL LANDSCAPE INSTALLATION ON THE SUBJECT PROPERTY, AND NOT ON ADJACENT PROPERTIES, UNLESS OTHERWISE DIRECTED BY THE OWNER OR THE OWNER'S REPRESENTATIVE. ROOTBALLS OF SHRUBS AND TREES SHALL BE PLANTED, IN THEIR ENTIRETY, WITHIN THE BOUNDARIES OF THE SUBJECT PROPERTY. N. QUANTITY TAKE -OFFS INDICATED ON THE PLANTING SCHEDULE ARE FOR CONVENIENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE Q UANTITIES SHOWN ON THESE PLANS PRIOR TO PRICING THE WORK. IN THE EVENT OF A DISCREPANCY BETWEEN THE PLANS AND THE SCHEDULE, THE GRAPHIC REPRESENTATION IN THE PLANS SHALL DICTATE. 0. ALL LANDSCAPED AND LAWN AREAS ARE TO BE IRRIGATED. P. ALL AREAS TO BE LANDSCAPED OR COVERED WITH MULCH MUST BE TREATED WITH A PRE - EMERGENCE HERBICIDE (SURFLAN, DACTAL OR APPROVED EQUAL) IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE REGULATIONS AND THE MANUFACTURER'S INSTRUCTIONS. Q. PLANTING BEHIND PERPENDICULAR PARKING IS TO BE LOCATED A MINIMUM OF 5' BEHIND THE CURB LINE. R. THE LANDSCAPE INSTALLATION CONTRACTOR THAT INSTALLS THE PROJECT PLANT MATERIAL SHALL BE RESPONSIBLE FOR ESTABLISHING AND GUARANTEEING A HEALTHY AND VIGOROUS LANDSCAPE FOR A PERIOD OF TWO (2) YEARS AFTER SUBSTANTIAL COMPLETION. S. THE OWNER RESERVES THE RIGHT TO INSPECT, AND POTENTIALLY REJECT ANY PLANTS THAT ARE INFERIOR, COMPROMISED, UNDERSIZED, DISEASED, INSTALLED INCORRECTLY OR DAMAGED. NOTES: 1. TOP OF SHRUB ROOTBALLS TO BE PLANTED 1" - 2" HIGH WITH SOIL MOUNDING UP TO THE TOP OF R001BALL 2. PRUNE SHRUBS AS DIRECTED BY OWNER'S REPRESENTATIVE. 3. 3" MINIMUM OF MULCH AS SPECIFIED. WHERE SHRUBS ARE PLACED IN MASSES, MULCH SHALL BE SPREAD IN A CONTINUOUS BED. AN APPROVED WEED BARRIER FABRIC SHALL BE INSTALLED IN ALL PLANTING BEDS. 4. SOIL BERM TO HOLD WATER. TOP OF PLANTING PIT 'BERM' TO BE LEVEL ACROSS PIT. SLOPE DOWNHILL PORTION OF BERM AS REQUIRED TO MEET EXISTING GRADE. MULCH OVER EXPOSED TOPSOIL. 5. FINISHED GRADE (SEE GRADING PLAN) 6. PREPARED PLANTING SOIL AS SPECIFIED. (SEE LANDSCAPE NOTES). 7. SCARIFY ROOTBALL SIDES AND BOTTOM. NOTES: A. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. NTS 120' 120' PLAN 1. ARBORTIE OR EQUAL SEE TIE DETAIL THIS SHEET (NOTE FOR MULTI -TRUNK TREES, USE SEPARATE GUYS TO STRONGEST TRUNKS AT CENTER OF EACH). 2. 3 1.5" X 8' MIN. SQUARE OR ROUND STAKES SPACED EVENLY IN A RADIAL PATTERN AROUND TREE. 3. 3" MINIMUM OF MULCH AS SPECIFIED. WHERE TREES ARE PLACED IN SOD, MULCH RING FOR TREES SHALL EXTEND APPROX. 6" BEYOND EARTH SAUCER /BERM UNLESS INDICATED OTHERWISE BY OWNERS REPRESENTATIVE. AN APPROVED WEED BARRIER FABRIC SHALL BE INSTALLED IN ALL PLANTING BEDS. 4. SOIL BERM TO HOLD WATER. (NOTE REQUIRED FOR TREES IN SIDEWALK TREE PLANTERS). 5. FINISHED GRADE (SEE GRADING PLAN) 6. TOP OF ROOTBALL MIN. 1" ABOVE FINISHED GRADE 7. B & B OR CONTAINERIZED (SEE SPECIFICATIONS FOR ROOT BALL REQUIREMENTS). 8. PREPARED PLANTING SOIL AS SPECIFIED. (SEE LANDSCAPE NOTES) 9. ROOTBALLS GREATER THAN 24" DIAMETER SHALL BE PLACED ON MOUND OF UNDISTURBED SOIL TO PREVENT SETTLING ROOTBALLS SMALLER THAN 24" IN DIA. MAY SIT ON COMPACTED EARTH. 10. APPROVED WEED BARRIER. 11. FLAG ALL TREE TIES WITH BRIGHTLY COLORED FLAGGING. NOTES: A. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO • ALL TREES SHALL BE PLUMB VERTICALLY WITHIN A INSTALLATION. TOLERANCE OF THREE DEGREES, UNLESS OTHERWISE 9 B. FINAL TREE STAKING DETAILS AND DIRECTED BY OWNER'S REPRESENTATIVE. PLACEMENT TO BE APPROVED BY OWNER. C. TREE SAVER ANCHORING SYSTEM MAY BE SUBSTITUTED FOR WOOD STAKING SYSTEM Small Tree Planting UPON APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE AND HENRICO COUNTY . SECTION (TREES UNDER 3.5" CAL. OR 14' IN HEIGHT) NTS 120' 180' 1. ARBORTIE OR EQUAL (NOTE FOR 120' MULTI -TRUNK TREES, USE SEPARATE GUYS I ' TO STRONGEST TRUNKS AT CENTER OF - /1", '� - &, EACH). '), C MEDIUM AND LARGE TREE'S 2. 3 1.5" X 8' MIN. SQUARE OR ROUND STAKES SPACED EVENLY IN A RADIAL 180' � 1.5" CALIPER AND PATTERN AROUND TREE. SMALL DECIDUOUS AND GREATER STAKING PLAN 3. 3" MINIMUM OF MULCH AS SPECIFIED. EVERGREEN TREE WHERE TREES ARE PLACED IN SOD, MULCH STAKING PLAN 1_,4f RING FOR TREES SHALL EXTEND APPROX. 6" %O 9% BEYOND EARTH SAUCER /BERM UNLESS 1 INDICATED OTHERWISE BY OWNERS 11 REPRESENTATIVE. AN APPROVED WEED 11 BARRIER FABRIC SHALL BE INSTALLED IN ALL PLANTING BEDS. 4. SOIL BERM TO HOLD WATER. (NOTE ?5 "o rl __ I )'2 REQUIRED FOR TREES IN SIDEWALK TREE PLANTERS). �1 5. FINISHED GRADE SEE GRADING PLAN ,I 3 6. TOP OF ROOTBALL MIN. 1 " ABOVE FINISHED EXISTING GRADE ! GRADE (DASHED) 7. B & B OR CONTAINERIZED (SEE 4 SPECIFICATIONS FOR ROOT BALL REQUIREMENTS). 8. PREPARED PLANTING SOIL AS SPECIFIED. 5 (SEE LANDSCAPE NOTES) . 9. ROOTBALLS GREATER THAN 24" DIAMETER SHALL BE PLACED ON MOUND OF ° .. UNDISTURBED SOIL TO PREVENT SETTLING :.� ROOTBALLS SMALLER THAN 24 ., .� _ 6 IN DIA. MAY 1O - '.; SIT ON COMPACTED EARTH. _ 10. APPROVED WEED BARRIER. 7 11. FLAG ALL TREE TIES WITH BRIGHTLY COLORED FLAGGING. `D - NOTES: 12 8 A. CONTRACTOR SHALL ASSURE PERCOLATION TYP, OF ALL PLANTING PITS PRIOR TO INSTALLATION. 9 B. FINAL TREE STAKING DETAILS AND • ALL TREES SHALL BE PLUMB VERTICALLY WITHIN A TOLERANCE OF PLACEMENT TO BE APPROVED BY OWNER. THREE DEGREES, UNLESS OTHERWISE DIRECTED BY OWNER'S C. TREE SAVER ANCHORING SYSTEM MAY BE REPRESENTATIVE. SUBSTITUTED FOR WOOD STAKING SYSTEM UPON APPROVAL BY OWNER OR OWNER'S Tree Planting o n a Slope REPRESENTATIVE AND HENRICO COUNTY. SECTION NTS BEST FACE OF SHRUB/ GROUNDCOVER TO FACE FRONT OF PLANTING BED. REFER TO PLANT SCHEDULE FOR SPACING. MAINTAIN 12" DEAD ZONE AT BED EDGE. I Y $ PLAN TYP. ES CTION • ALL SHRUBS AND GROUNDCOVERS SHALL BE PLUMB VERTICALLY, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. Shrub /Groundcover Plantin PLAN /SECTION NOTES: 1. TOP OF SHRUB ROOTBALLS TO BE PLANTED 1" - 2" HIGH WITH SOIL MOUNDING UP TO THE TOP OF ROOTBALL. 2. PRUNE ALL SHRUBS TO ACHIEVE A UNIFORM MASS /HEIGHT. 3. 3" MINIMUM MULCH AS SPECIFIED. AN APPROVED WEED BARRIER FABRIC SHALL BE INSTALLED IN ALL PLANTING BEDS. 4. EXCAVATE ENTIRE BED SPECIFIED FOR GROUNDCOVER BED. 5. FINISHED GRADE (SEE GRADING PLAN). 6. PREPARED PLANTING SOIL AS SPECIFIED. (SEE LANDSCAPE NOTES) NOTE: WHEN GROUND- COVERS AND SHRUBS USED IN MASSES, ENTIRE BED TO BE AMENDED WITH PLANTING SOIL MIX AS SPECIFIED. 7. SCARIFY ROOTBALL SIDES AND BOTTOM. NTS STORE NUMBER 10746 SEMINOLE TRAIL &RIO ROAD (NWC) ALBEMARLE COUNTY, VA. PROJECT TYPE NEW STORE DEAL TYPE­ FF3 I cs PRoUECT NuMeEft. 860471 ENGINEER: �t 11' � I, I � - 3 `t CONSULTANT KIMLEY -HORN AND ASSOCIATES, INC. 1700 WILLOW LAWN DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER: THE RE BKEE COMPANY 15871 CITY VIEW DRIVE, SUITE 300 MIDLOTHIAN, VA 23113 TEL: (804) 419 -0740 FAX: (804) 419 -0759 [S-EA-L.- REVISIONS: DRAWING BY: RRP DATE: OCTOBER 27, 2015 JOB NUMBER: 113001348 TITLE: LANDSCAPE NOTES AND DETAILS SHEET NUMBER: CP -501 COMMENTS: ��� n 7�� \�," : "" T . . D- Series Size 1 ;: F-7 ° LED Wall Luminaire iltir: . . DIS16N116NTS 1Ciighitiig 1 consaRrium facts TYPE WP DSXW1 -LED 10C- 1000 -40K- TFTM- MV0LT- DDBXD d "series • Configurable output to perfectly The D- Series Wall luminaire is a stylish, fully ."; „ , .' <: j match the LED load and maximize integrated LED solution for building -mount Specifications performance applications. It features a sleek, modern) design Luminaire Back Box (BBW, ELCW) and is carefully engineered to provide long- lasting, Width: 13 -3/4" Weight: 12 Ibs Width: 13 -3/4" BBW 5 Ibs energy - efficient lighting with a variety of optical (34 a cm) (54 kg) (34 9 cm) Weight: (' 3 kyl Luminaire BOM costs 1 0 4 „ ELCW 101bs and control options for customized performance. Depth: ( 25 4 cm) Depth: f 7 Q2 c ) Weight: ( a 5 k- a i With an expected service life of over 20 P Y ears of Height: 6 3/8" 9 r'o2cm) 6-3/8" Height: 3 9 r,6zc:m) 0 ni nighttime use an 74 In energy d u to /D e e 9 P gY�a savings • Short circuit, open circuit, ," over comparable 25OW metal halide lurminaires, _ rD � the D- Series Wall is a reliable, low- mainttenance _____.__- W __ H --- � _ H • UL Class 2 output for saafe lighting solution that produces 9 9 P ces s tits thalt are _.._�. F operation c. s exceptionally exce tionall illuminated. Y - -.I For 3/4" NPT side -entry efficient, constant current, multiple - channel 100W LED power supplies. e , ... conduit (BBW only) They are factory- configurable with available output currents between 11 EXAMPLE: DSXW1 LED 20C 1000 40K T3M MVOL'T DDBTXD DSXW1 LED Output Configurations Available Stamped ed bezel provides mechanical p be ..a t... t7" ... .. a a , , if 1w" a., 1 OOW 4 - .,M1 . DSXWTLED LEDs T2S TypellShnrt -VOLT! Shi edincluded • Weight - 45.0 pounds, EPA -1.3 ft' Shipped installed Shipped installed IDDBXD Darkbronze 1 contoured lines for continuity of style IN I 0 1 777 T2M T3S TypellMednim Type III Short 120' 208 blank) Surface mountln 9 ®ERIIIIII PE Photoelectriccell, button type' SF Smglefuse (1.0,217V) 2 DBLXD Black. and plumbed (oneengme) 20C 20 LEDs T31M TypeliMedium 2401 bracket CRI: 70 DMG 0- I OV dimming driver (nocontrols) DF Douhleftse DNAXD Natural aluminum Five year limited warranttyy (for more infor- (two engines) T4M Type IV Medium 2771 acr- mounted PIR 180 °mrn,n /ambient (208, 249n 1 DWHXD white Drive current TFTM r� Fe r/a Throw mom n backb x m light senser <15' "° HS House -side D SSXD rt Sand. one IMM hitp: / /www.designlights.org /OPL • Optional continuous dimming to 10% or Medium dual circuitry available n r". force � t • LED drivers Have output power over- nit ht 9 shield' 0087X0 Textured extu ed dark Emergency battery pack with enable a simple and consistent factory 350 350 mA EDXB eldoLED POWERdriv e DMX with RDM ( remote device manage- remote test switch installed option across all ABL lummaire i soli Y) PIRA 1 SO mo.o s / ambient S P D Separate a r ate surge bronze 530 530 mA nLight ®dimming pack controls to XPoint tech sheet. 0 -10V eldoLED drivers. ER = light sensor, 15 -30' protection'" DBLBXD Totured,13ek I la 7 7 m 1 ®I�O11111111111INOm ELCW mgght`" Emeraenc batter y Y Shipped separately DNATXD Texturedoatural 1000 000 mA (1 A) 0 ® backup includes BSW Bird- deterrent aluminum Color temperature I 11111111111111111111111 external component spbes9 DWHGXD Texturediihne 30K 3000K a »Tao 1111111111121111111111 enclosure)' , WG wreguad DSSTXD Textured 0 40K 4000K ' 0�0 I IIIIIIIIIII]IRIIIIIIIII VG Vandal guardI sandstone l 50K 50JOK a 'g NOTES I 11 1 MVOLT driver operates on an line voltage from 120 -277V (50/60 Hz. Specify 120 208 240 or 277 options only when ordering ACtessoAie$ i! P Y 1 I P fY P Y e 9 with fusing (SF, DF opba,sh or photocontrol (PE option). I0n,Wr1d0hd'eh,ppkd sa,, afa'v 2 Back box ships s installed on fixture Cannot be fit d installed Cannot be ordered as an accessory. 3 Photocwntrol (PE) requires 120, 208, 240 or 277 voltage option Not available with - tordambient fight sensors (PIR or PIRH). DSXWHS U Heuse-side shield foione pet light engine) 4 Specifies the See-, Switch SBR -IO -ODP control' see Mobon Sensor G -ii, for details, DSXWBSW U Sr - p d a Is. Includes ambient light sensor Not rd deterrent spl8eses available with "PE" option button tYP a photocell). Dimming driver standard Dsxwlw GU Wire ward accessor 9 Y < rs Y ifs h Sr­ nr wrtrh FtR- - - , -f 5 S c s the .. s- S 6 OD. control' see Mobcr Sensor �,i. e for details. In I de ambient I' h n r i cu s light so Not available Pr' g with "PE" option (button type photocell) Dimming driver standard. OS %W1VGU Vandal guard attessaory 6 Not available with 20 LED 11000 mA configuration (DSXW1 LED 20C 1000). 7 Not compatible with conduit entry applications. Not available with Sew mounting option. 8 Single fuse (SF) requires 120 or 277 voltage option Double fuse (Dn requires 208 or 240 voltage option. 9 Also available as a separate accessory, see Accessories information. 10 See the electrical section on page 2 for more details. IfAd171H011i One Lthonia Way - Conyers, Georgia 30012 • Phone: 800.279 8041 - Fax: 770.918 1209 • www bthoma corn I_®,'H7'1AAG © 2013 Acuity Brands Lighting, Inc All rights reserved VANIA TR CREATING TOM ROW t1i- n IN Dilm a -e D, o I 1 WOM"772MON7 "�, a • Configurable output to perfectly • OT100W - compact T5 profile - ."; „ , .' <: j match the LED load and maximize 1.18" x 1.0" (W X H) '' ` f performance •Universal InputVoltage'- r. • Multiple Class 2 Constant Current 120 -277V AC 50 /6OHz + - r x " ' output channels to reduce • Dimmable with 0 -1 OV dlimmers ® Luminaire BOM costs Included universal mounting bracket attaches securely to any 4" round or square outlet box ' for quick and easy installation. Luminaire has a slotted gasket wireway and attaches to the • High power factor and eefficiency °� ;• • Wide selection of standard pre- LISTINGS '� " * configured drive currents and • Short circuit, open circuit, ," custom configurations: overload and overheat p3rotection / a',. - OT100W 450mA to 700mA for sustained performamce J"jy Precision - molded proprietary acrylic lenses provide multiple photometric distributions Lad • UL Class 2 output for saafe iii m ® operation / GASKET ''I , 800.279.8041 • Fax. 770.918.1209 • www litho-, co-,. DSXW1 LED The OPTOTRONIC multi channel dimmable family consists of highly efficient, constant current, multiple - channel 100W LED power supplies. e , ... EMM They are factory- configurable with available output currents between 11 - fI 45OmA and 700mA. The 100W comes in a sleek T5 fluorescent ballast Output Configurations Available Stamped ed bezel provides mechanical p be housing that is only 1 "tall which is ideal for low profile luminaires. Ma1c'Power Number of Channels `' Drive Currrent - - - - -- + - -- - The family has built-in 0-1 OV dimming enabling direct integration 1 OOW 4 - 450fnA to 7(OOmA and operation with standard dimmers, sensors, as well as energy ' ®11111111M and light- management systems. 2500 Installation: Applications • Hi -Bay • Indirect/direct • Industrial • Linear • Recessed troffer ECS272132 4 -13 Specifications and Certifications S i l l J i l l Il loll l % @0 1 eoMnt dimmable this light source meets mWdw• 113 iI I1 lili'INl on nararoous substance OT100W - Compliant to 47 CFR, Part 15 Class B SEE THE WORLD IN A NEW LIGHT � .: R...�� 'a ;z >: 25'C , 77 -F 1.00 -,,, 30 "C 86 °F 1.00 40 1C 1047 1 0.98 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the DSXW1 LED 20C 1000 platform in a 25 "C ambient, based on 10,000 hours of LED testing (tested per IESNA LM- 80-08 and protected per IESNA TM 21 -11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating I p g hou rs be ow. For other lumen maintenance values, contact factory. A.; >::; > >!:..:::: >.: "::: ':. ate: �r..»;,. .;;;;: >: >:....."\�...::;;r';;;i '? :: \ " "::> .25 o ' !::Sffo i::>:::: >! 9Q:!:':il: >:: U b0 (P9::' :: >:'.... i'' �` >:.rt: f: [1: e : f:' ' \fix "::x xP. F i ,S o'''' ao.95 e 93 o.sa A > .1- Electrical Load PAMMIM <::x,. %, M, #.. AxL . ...24isl 7.. ...4.u. 2...:.:. se......,... is . 350 14W 1 0.13 0.07 0.06 0 06 - - IOC 530 2OW 0.19 0.11 0.09 008 - - 700 27W 0.25 0.14 0.13 0.11 - . 1000 _40W 0.37 021 0.19 0 16 - - 350 25W 0.23 0.13 0.12 0.10 - - 20C 530 36W 0.33 0.19 0.17 0,14 - - 700 47W 044 0.25 0.22 019 - 1000 75W 0.69 0.40 0.35 030 - - ® To see complete photometric reports or download .ies files for this product, visit Uthonia fighting's D- Series Wall Sae 1 homepage. Isofootcandle plots for the DSXW 1 LED 20C 1000 40K Distances are in units of mounting height (15') Distribution overlay comparison to 250VV metal halide. LEGEND 4 3 2 1 9 1 2 3 4 1 0 1 2 3 a .g 4 3 2, 9 1 z 3 4 LEGEND :: " ' s 4 3 2 l : o.t to 4 4 o . sxwt, :: ,.' fc 1: SSaa m .. Im 0.5 fc z .. .. .- .�..,...,.. -. ,v %v ": '. 2' 2 4 TWF2, _ -._ - _____ . B -- o }} ., � e 1 ... _ 0 1 TO, W idewalk 0 .. 5 2 rj ux: , a g 1wr2 m o.n 3 J .3 T3' + " 35 of DSXW1 .0.95 291W LED2th; 40n lfriw T3M11, DSXW1, T2M �4 M z` T 2a Z - - -- r . _ 9 w TWr2 2SOM Pulse, 15' M,,,,ting Ht FEATURES & SPECIFICATIONS a , a The energy sarongs, long Ilfe and easy le- install design of the D -Serves Wall Size 1 make lithe smart Light engine(s) consist of 10 high- efficacy LEDs mounted to a metal -core circuit board to choice for building mounted doorway and pathway illumination for nearly any facility, max-a heat dissipation and promote long life (L88/100,000 his at 25 °C). Class 1 electronic CONSTRUCTION drivers have a power factor >90 %, THD 20%, and a minimum 2.5KV surge rating When Two -piece die -cast aluminum housing has integral heat sink fins to optimize thermal management ordering the SPD opt on, a separate surge protection device is installed within the lummaire through conductive and convective cooling Modular design allows for ease of maintenance The which meets a mm-urn Category C Low (per ANSI /IEEE C62.41 2) 11 I ® ®i000®® Included universal mounting bracket attaches securely to any 4" round or square outlet box contaminants (IP65) for quick and easy installation. Luminaire has a slotted gasket wireway and attaches to the FINIS H mounting bracket via co r e corrosion-ies slant screws. s. 000m LISTINGS that provides superior resistance to corrosion and weathering, A tightly controlled multi -stage CSA certified to U S and Canadian standards. Rated for -40 °C minimum ambient ®�ib!Z�oll4omN0>DO LISTINGS changes without cracking or peeling Available in textured and non - textured finches. WARRANTY clamping voltage of 320V & surge rating of Five year limited warranty. Full warranty terms located at www .acwrybos,r A3 com/ OPTICS : us',ome,Rescurces/Tenns and conditions.asr:r. Precision - molded proprietary acrylic lenses provide multiple photometric distributions Lad roof seal around each '1 ® ®mm1I / GASKET 1%1YZ7 f1A One Lithonia Way • Conyers 30012 - Phone' 800.279.8041 • Fax. 770.918.1209 • www litho-, co-,. DSXW1 LED in0 mm11110 • recommended Drivers are 0 -1 OV dimming standard. for Type IllandT Y Type distributions �1111115�DIIIIi'O0 complete on /off and dimming control p 9 0 Stamped ed bezel provides mechanical p be ____ 31.6 compression to seal the optical assembly Lumen maintenance: Base Plate • L90 at 60,000 hours (Projected per IESNA • Complements the Hubbell Southwest ' ®11111111M ! 2500 Installation: • Weight - 45.0 pounds, EPA -1.3 ft' • Two die -cast aluminum arm designs: The iti0 decorative arm offers a sleek upswept look while the straight arm follows the housing's prescribed contoured lines for continuity of style Optics: • Fixture ships with arm installed for ease of • Choice of 72 high brightness LED configu- individual installation and mounts to #2 drill pattern rations with acrylic lenses ®ERIIIIII specially designed for TES Type II, III, IV and • Wall bracket, mast arm fitter and pole V distributions accessories are also available and plumbed allowing easy mounting for virtually Iio11�10 any application LED options Finish: CRI: 70 • TGIC thermoset e oset of ester ow e r c' ot finish a pp lied at nominal mil thi kn e ss Electrical: Warren • Universal input voltage 120 -277 VAC, Five year limited warranttyy (for more infor- _� mation visit: htto: /Jwww.11ubbelloutdoor.com/ ALL AROUND. resourcesJwarrant I • Integral step -down transformer for 347V ��1D11111IN & 480V Listings: • Listed to UL1598 and CSA C22.2 #250.0- • Ambient operating temperature -40'C to 40° C 24 for wet locations mom • Models meet DesignLights Consor- m I, • Drivers have greater than 90% power DLC webslte for more details: IMM hitp: / /www.designlights.org /OPL • Optional continuous dimming to 10% or • IDA approved • IP65 dual circuitry available MM • LED drivers Have output power over- integral test switch RRL_ RELOC'• -ready luminaireconnectors ®�IM Emergency battery pack with enable a simple and consistent factory ; EDXB eldoLED POWERdriv e DMX with RDM ( remote device manage- remote test switch installed option across all ABL lummaire i ment). Minimum dimming level <1 %. Includes termination NPS80EZT nligflt ®dimming pack controls brands. Referto RRL for complete resistor. Minimum lumen 1500 /Maximum lumen 3000. 0 -10V eldoLED drivers. nomenclature. EXA1 XPomtWireless, eldoLED ECOdrive 1% dimming, 0 -10V. Refer NPS80EZERt'e nLight ®dimming pack controls to XPoint tech sheet. 0 -10V eldoLED drivers. ER = EXAB XPoint Wireless, eldoLED SOlOdrive <1% dimming, 0 -10V. controls fixtures an emergency I la all 1 ®I�O11111111111INOm , 0 ® =1 , I 11111111111111111111111 M 0 ®0 a »Tao 1111111111121111111111 a- 0 1 0 0 ' 0�0 I IIIIIIIIIII]IRIIIIIIIII ®111111110 l o© a 'g ®umm 1 © MIM �IOO MA ®0 ©© � I. ®D a DA I ® ®010 i01�10® a II ®Di�� a ®1111111111�111111oOi11Q0000 In ®11111IM1111111111O I OmE =MMM 0�10M 0 ' �MM�M0 =®��o © �®®�� �oMM11MMOM ' IMMM =1 0"MI M 0 I a lnimi®�®©II0= =- = "© : a ==i�I110 :a ®010 © = Illlf��© t si'T's®®I�IIIIM=m 25'C , 77 -F 1.00 -,,, 30 "C 86 °F 1.00 40 1C 1047 1 0.98 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the DSXW1 LED 20C 1000 platform in a 25 "C ambient, based on 10,000 hours of LED testing (tested per IESNA LM- 80-08 and protected per IESNA TM 21 -11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating I p g hou rs be ow. For other lumen maintenance values, contact factory. A.; >::; > >!:..:::: >.: "::: ':. ate: �r..»;,. .;;;;: >: >:....."\�...::;;r';;;i '? :: \ " "::> .25 o ' !::Sffo i::>:::: >! 9Q:!:':il: >:: U b0 (P9::' :: >:'.... i'' �` >:.rt: f: [1: e : f:' ' \fix "::x xP. F i ,S o'''' ao.95 e 93 o.sa A > .1- Electrical Load PAMMIM <::x,. %, M, #.. AxL . ...24isl 7.. ...4.u. 2...:.:. se......,... is . 350 14W 1 0.13 0.07 0.06 0 06 - - IOC 530 2OW 0.19 0.11 0.09 008 - - 700 27W 0.25 0.14 0.13 0.11 - . 1000 _40W 0.37 021 0.19 0 16 - - 350 25W 0.23 0.13 0.12 0.10 - - 20C 530 36W 0.33 0.19 0.17 0,14 - - 700 47W 044 0.25 0.22 019 - 1000 75W 0.69 0.40 0.35 030 - - ® To see complete photometric reports or download .ies files for this product, visit Uthonia fighting's D- Series Wall Sae 1 homepage. Isofootcandle plots for the DSXW 1 LED 20C 1000 40K Distances are in units of mounting height (15') Distribution overlay comparison to 250VV metal halide. LEGEND 4 3 2 1 9 1 2 3 4 1 0 1 2 3 a .g 4 3 2, 9 1 z 3 4 LEGEND :: " ' s 4 3 2 l : o.t to 4 4 o . sxwt, :: ,.' fc 1: SSaa m .. Im 0.5 fc z .. .. .- .�..,...,.. -. ,v %v ": '. 2' 2 4 TWF2, _ -._ - _____ . B -- o }} ., � e 1 ... _ 0 1 TO, W idewalk 0 .. 5 2 rj ux: , a g 1wr2 m o.n 3 J .3 T3' + " 35 of DSXW1 .0.95 291W LED2th; 40n lfriw T3M11, DSXW1, T2M �4 M z` T 2a Z - - -- r . _ 9 w TWr2 2SOM Pulse, 15' M,,,,ting Ht FEATURES & SPECIFICATIONS Cat.# INTENDED USE ELECTRICAL The energy sarongs, long Ilfe and easy le- install design of the D -Serves Wall Size 1 make lithe smart Light engine(s) consist of 10 high- efficacy LEDs mounted to a metal -core circuit board to choice for building mounted doorway and pathway illumination for nearly any facility, max-a heat dissipation and promote long life (L88/100,000 his at 25 °C). Class 1 electronic CONSTRUCTION drivers have a power factor >90 %, THD 20%, and a minimum 2.5KV surge rating When Two -piece die -cast aluminum housing has integral heat sink fins to optimize thermal management ordering the SPD opt on, a separate surge protection device is installed within the lummaire through conductive and convective cooling Modular design allows for ease of maintenance The which meets a mm-urn Category C Low (per ANSI /IEEE C62.41 2) LED driver is mounted to the door to thermally isolate t from the light engines for low c,perating INSTALLATION temperature and long life Housing is completely sealed against moisture and environmental Included universal mounting bracket attaches securely to any 4" round or square outlet box contaminants (IP65) for quick and easy installation. Luminaire has a slotted gasket wireway and attaches to the FINIS H mounting bracket via co r e corrosion-ies slant screws. s. Exterior arts are protected b a -c-infused infused Su er Durable TGIC thermoset P p G C t er noset owder coat finish Y P sh P LISTINGS that provides superior resistance to corrosion and weathering, A tightly controlled multi -stage CSA certified to U S and Canadian standards. Rated for -40 °C minimum ambient process ensures a minimum 3 cods thickness for a finish that can withstand extreme climate LISTINGS changes without cracking or peeling Available in textured and non - textured finches. WARRANTY clamping voltage of 320V & surge rating of Five year limited warranty. Full warranty terms located at www .acwrybos,r A3 com/ OPTICS : us',ome,Rescurces/Tenns and conditions.asr:r. Precision - molded proprietary acrylic lenses provide multiple photometric distributions Lad roof seal around each specifically to build,ng mounted apph , tions I ight engines are available in 3000K (80 min CRI), Note: Siz- ficattons subject to change without notice. 4000K (70 min. CRI) or SOOOK (65 min. CR) configurations / GASKET 1%1YZ7 f1A One Lithonia Way • Conyers 30012 - Phone' 800.279.8041 • Fax. 770.918.1209 • www litho-, co-,. DSXW1 LED LS.Aa2F'IrIAI' l © 2013 Acuity Brands Lighting, Inc. All rights reserved Rev. 10/08'13 SSS SERIES Gat.# srMraut-E311111111,1411113 Job Type *' L I G H T I N G POLES Approvals SQUARE STRAIGHT STEEL APPLICA77ONS • Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location. FEATURES • SHAFT: One -piece straight steel with square cross section, flat sides and minimum 0.36" radius on all corners. Minimum yield of 46,000 psi (ASTM -A500, Grade B). Longitudinal weld seam to appear flush with shaft side wall. Steel base plate with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ATM -A36). • BASE COVER: Two -piece square aluminum base cover included standard. • POLE CAP: Pole shaft covered with removable non - metallic cover when applicable. Tenon and post -tap configurations also available. • HAND HOLE: Rectangular steel- reinforced hand hole (2.5" x 4.5 "). Pole grounding lug located behind gasketed cover. • ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (modi- fied ASTM-A36). Galvanized hardware with two washers/nuts per bolt for leveling meet or exceed bolt strength. • FINISH: Durable Lektrocotel TGIC thermoset polyester powder coat paint finish with nominal 3.0 mil thickness. Zinc -rich powder paint prime applied over "white metal" steel substrate cleaned via mechanical shat blast method. Decorative finish coat available in seven standard colors. Custom colors available. RAL number preferable. Internal protective coating available. Nominal Height It ./ ;, CIMARRON Cat.# THE R EBKEE COMPANY LEDJob 1 M+m Type 2113 [55.4] - -- - - 1 U"; N 0 = . O SPECIFICATIONS N Construction: voltage, over- current protection and short • Stylish vertically finned die -cast solid top circuit protection with auto recovery housing for maximum heat dissipation; Stops collection of unsightly debris from on top of the housing • 1050 mA driver available with 90L con - gathering figuration for increased lumen output • Rugged lower die -cast aluminum heat 1paccelerates r acre a ales thermal management • LED electrical assembly, including PR devices, and optimizes PCB and optical perfor- consumes no power in the 'off' state mance RECEPTACLE & COVER LISTINGS • Surge protection of 20KA 8/20 pSec wave; • Separate optical and electrical compart- clamping voltage of 320V & surge rating of ment for optimum component operation 273J One lece die cut silicone gasket ensures we tp a her Controls: roof seal around each Features exclusive wi e HUBS technology 9Y individual LED for IP65 rating - Wireless system for On /Off and / GASKET 0 -1 OVDC full range dimming control • Backlight Control (BC) option available for - Programmable autonomous operation 85 °/D spill light reduction, doesn't change fixture appearance or EPA, • recommended Drivers are 0 -1 OV dimming standard. for Type IllandT Y Type distributions Photocell and occupancy cY sensors available complete on /off and dimming control p 9 0 Stamped ed bezel provides mechanical p be ____ 31.6 compression to seal the optical assembly Lumen maintenance: Base Plate • L90 at 60,000 hours (Projected per IESNA • Complements the Hubbell Southwest TM- 21 -11) series of outdoor fixtures ! 2500 Installation: • Weight - 45.0 pounds, EPA -1.3 ft' • Two die -cast aluminum arm designs: The • Suitable for applications reqqujring 3G testing by ANSI C136.31 decorative arm offers a sleek upswept look while the straight arm follows the housing's prescribed contoured lines for continuity of style Optics: • Fixture ships with arm installed for ease of • Choice of 72 high brightness LED configu- individual installation and mounts to #2 drill pattern rations with acrylic lenses ,'. , specially designed for TES Type II, III, IV and • Wall bracket, mast arm fitter and pole V distributions accessories are also available and plumbed allowing easy mounting for virtually • CCT: 3000K 80 CRI 4000K 00 (70 CRI), 5100K (67 C I), an turtle friendly Amber any application LED options Finish: CRI: 70 • TGIC thermoset e oset of ester ow e r c' ot finish a pp lied at nominal mil thi kn e ss Electrical: Warren • Universal input voltage 120 -277 VAC, Five year limited warranttyy (for more infor- 50J60 Hz mation visit: htto: /Jwww.11ubbelloutdoor.com/ ALL AROUND. resourcesJwarrant I • Integral step -down transformer for 347V & 480V Listings: • Listed to UL1598 and CSA C22.2 #250.0- • Ambient operating temperature -40'C to 40° C 24 for wet locations • Automatic thermal self - protection • Models meet DesignLights Consor- tium (DLC) qualifications, consult • Drivers have greater than 90% power DLC webslte for more details: factor and less than 10 %THD hitp: / /www.designlights.org /OPL • Optional continuous dimming to 10% or • IDA approved • IP65 dual circuitry available i • LED drivers Have output power over- integral test switch RRL_ RELOC'• -ready luminaireconnectors level <1 %.Minimum lumen 1500 /Maximum lumen 3000. ELR' ; - SFMR JL-13IN13 �_lL I G H T I N G Approvals PRODUCT IMAGE(S) .. x ...r s,,..:i: :,,, >Ni 1: >s:.., 4 90 LED 3/4 VIEW 30 LED rr ::._.: �r �r r x- k. a ' ax "�-: I 60 LED 90 LED TENSIONS Upswept Arm - G -i 'I A _ __ I L7di i J i B ' -I Straight Arm �_ E _._I -- i -- ., - - -- -- D )�8U �7� A � - --- - - - - - -- B - - I - - - -- F b 7 z '�-.. �- _ -1 I- C CER11"'ATrONS/LISTINGS � 4t5 A B C D E F G II htiri „ „ I 1 1 m 21 ?/4 16 g 65/6 65/,6' 5 5 /8" 61 " SH wr�tliBB 1 /8 171mm 552mm 406mm (y`M� 168m 1 , C •� / m 60n m 143mm 155mm Ds - rLUn,r far > )hrrAr F v" ..�.,...,�.. �16Y' Merteh ORDERING INFORMATION SEE NEXT PAGE Spaulding Lighting �� SPIfaUt_DING p g 0 9 701 Millennium Boulevard Greenville, SC 29607 •Phone. 864 - 678 -1000 UBBELL HUBBELL L i G H T N G Due to our continued efforts to improve our products, product specifications are subject to change without notice. Lighting ® 2014 SPAULDING LIGHTING, All Rights Reserved • For more information visit our we0.site: www.spauldinglighting.com • Printed in USA CL7 LED -SPEC 9/14 -- - - -- -- -------- -- - - -- - -- - -- -- 8" EVO Downlight got hamm Solid -State Lighting ,8,. 3 I All dimensions are inches (centimeters),Unless otherwise noted. m- - 'r' _. -_ -_ 2 "nI � ; - - I i - C 2 ! � � I / - •' \ !I';' 88 [22.0] 1 */, c ® • 1 ) 15 8 [40.31 . - a 1 I �/ - 4 i- Aperture: 8-5/8 (21.9) Ceiling Opening: 8 -3/4 (22.2) . . Overlap Trim: 9 -1/4 (23.5) aL-tillild DIMENSIONS FOR CHICAGO PLENUM 37.0] i (� _ I' 9Tb I24.Oj l Anchor Bolt Z 0 -i Location in P1 N ' i Relation I to Shaft Rotation Handhole I I ESSORIES order as separate catalog numbers (shipped separately) �Ek1ERGENCY1I... 'pkh alas ,.:, mss, ,.... s, .... AUMENS +_WATTAGE I 'INITIAL OUTPUT 2000 8.4 630 - - - -- 1 - - - - - -- - �I1 2500 7.2 540 3000 I 8.4 _ -_I_ 630 It I Sloped ceiling adapter. Degree of slope must be specified (50, 10D, 150, 20D, 25D, 30D). Ex: SCAB IOD. Refer to TECH -190. -8 YK Ceiling thickness adapter (extends mounting frame to accommodate ceiling thickness up to 5"). Adds P to fixture height. Va n da l- resistant trim accessory. Refer to TECH -200. iC 0 -IOV wallbox dimmer. Refer to ISD SC. ORDERING NOTES,,,,, 1. Not available with finishes. 6. For dimensional changes, refer to TECH -140. Not ava!'able with 347V 2. Not available with EL or ELR options. 7. Specify vohage. 3. Refer to TE H_240 for compatible dimmers. 8. For use with generator supply EM power. Will require an emergency hot feed and normal hot feed. 4. Not available with white reflector. 9. ELR not available. 5. Not available with black reflector 7.36" (187) Adjustable 1/2" - 3/4" ....... Pressure Fit ­ 5.00" (11 27) - - -- -- 5.00 "(127) '� ~ -�\ I / :6' a, ` !/; 6"N j ' f ,I it ') .1 2.72" / ,/ - 1 I I �\ �l) I ,\ \ 4`\ Sic l ) (69) -------- __ / 1 (�,�\\,, � j - - ® J% DOWNUIGHT ELECTRICAL • Recessed fixed downlight • Remotely installed LED driver • Die-cast aluminum trim • Separated primary wiring compartment with integral power supply Powder coat finish s •Double cable entry for through wiring • Superpure aluminum reflector HOUSING • Dimmable • Extruded aluminum central housing • Powder coat finish MOUNTING • Dust and water jet tight sealed • Swing out pressure fit mounting clips • Ceiling Cut -Out - 04.65" • Adjustable up to 1.18" max, ceiling thickness LED SOURCE LABELS • Field replaceable LED • Suitable for wet location • Field- clhangeable optic • Title 24 Compliant • 2OW / 10006n, 30CRI / 3000K • IP66 rated • Accepts up to 2 or more optical accessories 1 Limited c us ORDERIMIG INFO . a •. • •_ 1 -_ _ .. 2OL 2OW LED 18027 80GRI / 2700K N Narrow LD ;5811 -7SA -T LED Driver IBB Black CP Chicago Plenum i 1000Im 8030 SOCRI / 3000K e,ium D1 Phase Dimming m n U 120 -277V Emergency S Silver EM 9 Eme tic Rela from n 9 Y Y "'0J"VOic7e 'BULLET Reecessed '8040 80GRI /4000K - I iD201 V I Die -Cast Alwminum Trim 0 Dimming Fixed Downhli ht I 120 -277V 9 Trimmed Fixcture 9030 90LRI / 3000K utron o- icon 9727 97C: 11 / 2700K I 120 -277V 'Consult Factory 9730 97CRI / 3000K ! D4 Lutron Eco- System - - -- I - - - - - -1 - _ __ ___- - - - - - --- -- . 1 20-7V -_ -. _ 27 I_ __ - -- - - -. _-- - -.._ -- - -_ - -- _._ Ordering Example; 5811- 1SA -T20L- 8030- N- D1- 1 -SS-CP 02013 LF ILLUMINATION LLC HEADQUARTERS Telephone. 818 -885 -1335 We reserve! tho right to change or 9200 Deering www.lfillumination.com 9 t: g Avenue Toll Free: 855 - 885 -1335 w.lfillumination.com withdra w s r P ec ifi cations without lit prior notice. Chatsworth CA 91311 Fax: 81 $ - 576 - 1335 1 rev' t 1 1n o got h a mM • I r 0 ■ ■ 0 ■ A ■ , ■ ■ STORE NUMBER: 10746 SEMINOLE TRAIL & RIO ROAD (NWC) ALBEMARLE COUNTY, VA. � A' PROXCT TYPE: NEW STORE ST DM TYPE- - CS PROJECT NUMBER 86047 ENGINEER '� .1 A , 1, h I i 4 ,I � � , ! ti , CONSULTANT KIMLEY -HORN AND ASSOCIATES, INC. 1700 WILLOW LOW LAW N DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER: 018 OPTION THE R EBKEE COMPANY Handhole 72" 1 M+m O O 2113 [55.4] - -- - - 1 U"; N 0 = . O I N - - - -- � I - I - - - -- -- -- - -- - -- - - - -- _ _ BASE DETAIL 20 AMP GFCI W • Overload and short circuit protected y Bolt Circle Polyciarbonate lens integral to light engine • 2.5 SDCM; 85 CRI typical, 90+ CRI optional RECEPTACLE & COVER LISTINGS > 1NATTAGECONSUMPTIONMATiY1X .. `' l,,' Anchor Rod Fixtures are CSA certified to meet US and Canadian standards; wet location, - �. a. .,il,�..., a .. ...... Hex Nut \ 4" verrtical adjustment / GASKET I LUMENS ": LM ACTUAL I ,,WATTAGE LUMENSperWATT''' Plain Washer - \ `-i(zt� r www.acuitybra is.Lom/Qg5tcLi erResourCeS TeLin and condittgns.aspx 2000 2,281 - ____ 31.6 72.5 Base Plate All values are design or typical values, measured under laboratory conditions at ! 2500 2,964 41.1 72.0 EXAMPLE: IEVO 35/25 BAR MWD LSS 120 ED Grout Finish Grade Bolt Projection I I Plain washer - , Color temperature Nominal lumen values Aperture /Trim color Distribution Finish Voltage I J EVO 3000 3,398 47.1 72.2 Hex Nut ., Grout after pole is set /! - ,'. , 33 NO Narrow (0.7 s /mh) LO Matte - diffuse 277 a 1 -- _ - - -__- and plumbed Engineering of z I 401 4000 K 8GR Gold MWD Medium wide (1.0 s /mh) Foundation Level footing by others COVER GASKET) 1/4' FILLET WELD- WO Wide (1.2 s /mh) i 8BR1 Black ALL AROUND. White anti Anchor Bolt Z 0 -i Location in P1 N ' i Relation I to Shaft Rotation Handhole I I ESSORIES order as separate catalog numbers (shipped separately) �Ek1ERGENCY1I... 'pkh alas ,.:, mss, ,.... s, .... AUMENS +_WATTAGE I 'INITIAL OUTPUT 2000 8.4 630 - - - -- 1 - - - - - -- - �I1 2500 7.2 540 3000 I 8.4 _ -_I_ 630 It I Sloped ceiling adapter. Degree of slope must be specified (50, 10D, 150, 20D, 25D, 30D). Ex: SCAB IOD. Refer to TECH -190. -8 YK Ceiling thickness adapter (extends mounting frame to accommodate ceiling thickness up to 5"). Adds P to fixture height. Va n da l- resistant trim accessory. Refer to TECH -200. iC 0 -IOV wallbox dimmer. Refer to ISD SC. ORDERING NOTES,,,,, 1. Not available with finishes. 6. For dimensional changes, refer to TECH -140. Not ava!'able with 347V 2. Not available with EL or ELR options. 7. Specify vohage. 3. Refer to TE H_240 for compatible dimmers. 8. For use with generator supply EM power. Will require an emergency hot feed and normal hot feed. 4. Not available with white reflector. 9. ELR not available. 5. Not available with black reflector 7.36" (187) Adjustable 1/2" - 3/4" ....... Pressure Fit ­ 5.00" (11 27) - - -- -- 5.00 "(127) '� ~ -�\ I / :6' a, ` !/; 6"N j ' f ,I it ') .1 2.72" / ,/ - 1 I I �\ �l) I ,\ \ 4`\ Sic l ) (69) -------- __ / 1 (�,�\\,, � j - - ® J% DOWNUIGHT ELECTRICAL • Recessed fixed downlight • Remotely installed LED driver • Die-cast aluminum trim • Separated primary wiring compartment with integral power supply Powder coat finish s •Double cable entry for through wiring • Superpure aluminum reflector HOUSING • Dimmable • Extruded aluminum central housing • Powder coat finish MOUNTING • Dust and water jet tight sealed • Swing out pressure fit mounting clips • Ceiling Cut -Out - 04.65" • Adjustable up to 1.18" max, ceiling thickness LED SOURCE LABELS • Field replaceable LED • Suitable for wet location • Field- clhangeable optic • Title 24 Compliant • 2OW / 10006n, 30CRI / 3000K • IP66 rated • Accepts up to 2 or more optical accessories 1 Limited c us ORDERIMIG INFO . a •. • •_ 1 -_ _ .. 2OL 2OW LED 18027 80GRI / 2700K N Narrow LD ;5811 -7SA -T LED Driver IBB Black CP Chicago Plenum i 1000Im 8030 SOCRI / 3000K e,ium D1 Phase Dimming m n U 120 -277V Emergency S Silver EM 9 Eme tic Rela from n 9 Y Y "'0J"VOic7e 'BULLET Reecessed '8040 80GRI /4000K - I iD201 V I Die -Cast Alwminum Trim 0 Dimming Fixed Downhli ht I 120 -277V 9 Trimmed Fixcture 9030 90LRI / 3000K utron o- icon 9727 97C: 11 / 2700K I 120 -277V 'Consult Factory 9730 97CRI / 3000K ! D4 Lutron Eco- System - - -- I - - - - - -1 - _ __ ___- - - - - - --- -- . 1 20-7V -_ -. _ 27 I_ __ - -- - - -. _-- - -.._ -- - -_ - -- _._ Ordering Example; 5811- 1SA -T20L- 8030- N- D1- 1 -SS-CP 02013 LF ILLUMINATION LLC HEADQUARTERS Telephone. 818 -885 -1335 We reserve! tho right to change or 9200 Deering www.lfillumination.com 9 t: g Avenue Toll Free: 855 - 885 -1335 w.lfillumination.com withdra w s r P ec ifi cations without lit prior notice. Chatsworth CA 91311 Fax: 81 $ - 576 - 1335 1 rev' t 1 1n o got h a mM • I r 0 ■ ■ 0 ■ A ■ , ■ ■ STORE NUMBER: 10746 SEMINOLE TRAIL & RIO ROAD (NWC) ALBEMARLE COUNTY, VA. � A' PROXCT TYPE: NEW STORE ST DM TYPE- - CS PROJECT NUMBER 86047 ENGINEER '� .1 A , 1, h I i 4 ,I � � , ! ti , CONSULTANT KIMLEY -HORN AND ASSOCIATES, INC. 1700 WILLOW LOW LAW N DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER: 018 OPTION THE R EBKEE COMPANY n 1 M+m O O MIDLOTHIAN, VA U"; N 0 = . O O Bolt Square N • 45' cgutoff to source and source image ,�. O O W • Overload and short circuit protected y Bolt Circle Polyciarbonate lens integral to light engine • 2.5 SDCM; 85 CRI typical, 90+ CRI optional Anchor Bolt Z 0 -i Location in P1 N ' i Relation I to Shaft Rotation Handhole I I ESSORIES order as separate catalog numbers (shipped separately) �Ek1ERGENCY1I... 'pkh alas ,.:, mss, ,.... s, .... AUMENS +_WATTAGE I 'INITIAL OUTPUT 2000 8.4 630 - - - -- 1 - - - - - -- - �I1 2500 7.2 540 3000 I 8.4 _ -_I_ 630 It I Sloped ceiling adapter. Degree of slope must be specified (50, 10D, 150, 20D, 25D, 30D). Ex: SCAB IOD. Refer to TECH -190. -8 YK Ceiling thickness adapter (extends mounting frame to accommodate ceiling thickness up to 5"). Adds P to fixture height. Va n da l- resistant trim accessory. Refer to TECH -200. iC 0 -IOV wallbox dimmer. Refer to ISD SC. ORDERING NOTES,,,,, 1. Not available with finishes. 6. For dimensional changes, refer to TECH -140. Not ava!'able with 347V 2. Not available with EL or ELR options. 7. Specify vohage. 3. Refer to TE H_240 for compatible dimmers. 8. For use with generator supply EM power. Will require an emergency hot feed and normal hot feed. 4. Not available with white reflector. 9. ELR not available. 5. Not available with black reflector 7.36" (187) Adjustable 1/2" - 3/4" ....... Pressure Fit ­ 5.00" (11 27) - - -- -- 5.00 "(127) '� ~ -�\ I / :6' a, ` !/; 6"N j ' f ,I it ') .1 2.72" / ,/ - 1 I I �\ �l) I ,\ \ 4`\ Sic l ) (69) -------- __ / 1 (�,�\\,, � j - - ® J% DOWNUIGHT ELECTRICAL • Recessed fixed downlight • Remotely installed LED driver • Die-cast aluminum trim • Separated primary wiring compartment with integral power supply Powder coat finish s •Double cable entry for through wiring • Superpure aluminum reflector HOUSING • Dimmable • Extruded aluminum central housing • Powder coat finish MOUNTING • Dust and water jet tight sealed • Swing out pressure fit mounting clips • Ceiling Cut -Out - 04.65" • Adjustable up to 1.18" max, ceiling thickness LED SOURCE LABELS • Field replaceable LED • Suitable for wet location • Field- clhangeable optic • Title 24 Compliant • 2OW / 10006n, 30CRI / 3000K • IP66 rated • Accepts up to 2 or more optical accessories 1 Limited c us ORDERIMIG INFO . a •. • •_ 1 -_ _ .. 2OL 2OW LED 18027 80GRI / 2700K N Narrow LD ;5811 -7SA -T LED Driver IBB Black CP Chicago Plenum i 1000Im 8030 SOCRI / 3000K e,ium D1 Phase Dimming m n U 120 -277V Emergency S Silver EM 9 Eme tic Rela from n 9 Y Y "'0J"VOic7e 'BULLET Reecessed '8040 80GRI /4000K - I iD201 V I Die -Cast Alwminum Trim 0 Dimming Fixed Downhli ht I 120 -277V 9 Trimmed Fixcture 9030 90LRI / 3000K utron o- icon 9727 97C: 11 / 2700K I 120 -277V 'Consult Factory 9730 97CRI / 3000K ! D4 Lutron Eco- System - - -- I - - - - - -1 - _ __ ___- - - - - - --- -- . 1 20-7V -_ -. _ 27 I_ __ - -- - - -. _-- - -.._ -- - -_ - -- _._ Ordering Example; 5811- 1SA -T20L- 8030- N- D1- 1 -SS-CP 02013 LF ILLUMINATION LLC HEADQUARTERS Telephone. 818 -885 -1335 We reserve! tho right to change or 9200 Deering www.lfillumination.com 9 t: g Avenue Toll Free: 855 - 885 -1335 w.lfillumination.com withdra w s r P ec ifi cations without lit prior notice. Chatsworth CA 91311 Fax: 81 $ - 576 - 1335 1 rev' t 1 1n o got h a mM • I r 0 ■ ■ 0 ■ A ■ , ■ ■ STORE NUMBER: 10746 SEMINOLE TRAIL & RIO ROAD (NWC) ALBEMARLE COUNTY, VA. � A' PROXCT TYPE: NEW STORE ST DM TYPE- - CS PROJECT NUMBER 86047 ENGINEER '� .1 A , 1, h I i 4 ,I � � , ! ti , CONSULTANT KIMLEY -HORN AND ASSOCIATES, INC. 1700 WILLOW LOW LAW N DR, SUITE 200 RICHMOND, VA 23230 TEL (804) 673 -3882 FAX (804) 673 -3980 DEVELOPER: THE R EBKEE COMPANY 15871 CITY VIEW DRIVE, SUITE 300 • Self-fl 'langed semi - specular, matte - diffuse or specular finishing trim MIDLOTHIAN, VA 23113 TEL: (804) 419 -0740 Patentted Bounding Ray- optical design (U.S. Patent No. 5,800,050) FAX: (804) 419 -0759 N SEAL: AA (2.,,,,,,, j Gotham Architectural Downlighting - -' LED Downlights 8" Evo® Downlight irg > `.. ::.::; '. Solid -State Lighting )r;;„ ;;;I Spaulding Lighting - 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864 678 -1000 i Cw SPRULGING HUBBELL, HUBBELL GOTHAM ARCHITECTURAL DOWNUGHTING 1 1400 Lester Road Conyers GA 30012 1 P 800 315 4982 1 gothamlighting.com EVO -8 -OPEN EVO -8 -OPEN GOTHAM ARCHITECTURAL DOWNLIGHTING 1 1400 Lester Road Conyers GA 30012 1 P 800 315 -4982 1 gothamlighting.com / L i c x r i N u Due to our continued efforts to improve our products, product specifications are subject to change without notice. Lighting � goth a m• �''� ® 2014 SPAULDING LIGHTING, All Rights Reserved • For more information visit our websde. wwwApauldinglighting.com • Pointed In USA SSSPOLES -SPEC 7/14 ® 2010 -2015 Acmfy Brands Lighting, Inc. All Rights Reserved. Rev 09130115. Sixicificahons subject to change wltlmut notice I PAGE 2 OF 4 PAGE l OF 4 I ® 2010 -2015 Acuity Brands Lighting, Inc All Rights Reserved Rev 09/30/15. Specifications subj�t to change without notice. gotham' REVISIONS: DRAWING BY: RRP DATE: NOVEMBER 12, 2015 JOB NUMBER: 113001348 TI TLE: LIGHTING CIJTSHEETS SHEET NUMBER: CL -102 COMMENTS: OPTICAL SYSTEM ELECTRICAL SYSTEM 2, • Self-fl 'langed semi - specular, matte - diffuse or specular finishing trim • Fully serviceable and upgradeable lensed LED light engine a Patentted Bounding Ray- optical design (U.S. Patent No. 5,800,050) 70% lumen maintenance at 60,000 hours N • 45' cgutoff to source and source image • Tested according to LM -79 and LM -80 standards • Top - doown flash characteristic • Overload and short circuit protected Polyciarbonate lens integral to light engine • 2.5 SDCM; 85 CRI typical, 90+ CRI optional MECHANICALL SYSTEM LISTINGS • 16- gaauge galvanized steel construction; maximum 1 -1/2" ceiling thickness Fixtures are CSA certified to meet US and Canadian standards; wet location, • Telesczopic mounting bars maximum of 32" and minimum of 15 ", premstalled, covered ceiling 4" verrtical adjustment WARRANTY • Toolleess adjustments post installation • 5 -year limited warranty. Complete warranty terms located at: • Juncti ion box capacity: 8 (4 in, 4 out ) 12AWG rated for 90'C www.acuitybra is.Lom/Qg5tcLi erResourCeS TeLin and condittgns.aspx • Light (engine and driver accessible through aperture NDte: Actual performance may differ as a result of end user environment and application. All values are design or typical values, measured under laboratory conditions at 25 "C. - f0 z EXAMPLE: IEVO 35/25 BAR MWD LSS 120 ED zSeries Color temperature Nominal lumen values Aperture /Trim color Distribution Finish Voltage EVO 27/ 2700 K 20 20001umens BAR Clear VND Very narrow (0.5 s /mh) LESS Semi - specular 120 F i H 30/ 3000 K 25 2500 lumens 8PR Pewter NO Narrow (0.7 s /mh) LO Matte - diffuse 277 a 1 35/ 3500 K 30 30001umens BWTR Wheat MD Medium (0 9 s /mh) LS Specular 3471 z I 401 4000 K 8GR Gold MWD Medium wide (1.0 s /mh) 8WRI White WO Wide (1.2 s /mh) 8BR1 Black White anti microbial Driver' Options EZt eldoLED ECOdrive 0 -10V dimming driver. Minimum dimming SF Single fuse. Specify 120V or 277V. BGTD Bodine generator transfer device. range level 1% TRW' White painted flange Specify 120V or 277V. EZB eldoLED SOlOdrive 0 -10V dimming driver. Minimum dimming TRBL/ Black painted flange CRI90 High CRI (90 +) level <1 %. ELI Emergency battery pack with CPI Chicago plenum. Specify 120V or 277V. i EDAB eldoLED SOLOdrive DALI dimming driver Minimum dimming integral test switch RRL_ RELOC'• -ready luminaireconnectors level <1 %.Minimum lumen 1500 /Maximum lumen 3000. ELR' Emergency battery pack with enable a simple and consistent factory ; EDXB eldoLED POWERdriv e DMX with RDM ( remote device manage- remote test switch installed option across all ABL lummaire i ment). Minimum dimming level <1 %. Includes termination NPS80EZT nligflt ®dimming pack controls brands. Referto RRL for complete resistor. Minimum lumen 1500 /Maximum lumen 3000. 0 -10V eldoLED drivers. nomenclature. EXA1 XPomtWireless, eldoLED ECOdrive 1% dimming, 0 -10V. Refer NPS80EZERt'e nLight ®dimming pack controls to XPoint tech sheet. 0 -10V eldoLED drivers. ER EXAB XPoint Wireless, eldoLED SOlOdrive <1% dimming, 0 -10V. controls fixtures an emergency Refer to XPoint tech sheet. circuit Spaulding Lighting - 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864 678 -1000 i Cw SPRULGING HUBBELL, HUBBELL GOTHAM ARCHITECTURAL DOWNUGHTING 1 1400 Lester Road Conyers GA 30012 1 P 800 315 4982 1 gothamlighting.com EVO -8 -OPEN EVO -8 -OPEN GOTHAM ARCHITECTURAL DOWNLIGHTING 1 1400 Lester Road Conyers GA 30012 1 P 800 315 -4982 1 gothamlighting.com / L i c x r i N u Due to our continued efforts to improve our products, product specifications are subject to change without notice. Lighting � goth a m• �''� ® 2014 SPAULDING LIGHTING, All Rights Reserved • For more information visit our websde. wwwApauldinglighting.com • Pointed In USA SSSPOLES -SPEC 7/14 ® 2010 -2015 Acmfy Brands Lighting, Inc. All Rights Reserved. Rev 09130115. Sixicificahons subject to change wltlmut notice I PAGE 2 OF 4 PAGE l OF 4 I ® 2010 -2015 Acuity Brands Lighting, Inc All Rights Reserved Rev 09/30/15. Specifications subj�t to change without notice. gotham' REVISIONS: DRAWING BY: RRP DATE: NOVEMBER 12, 2015 JOB NUMBER: 113001348 TI TLE: LIGHTING CIJTSHEETS SHEET NUMBER: CL -102 COMMENTS: