Loading...
HomeMy WebLinkAboutSDP201000051 Review Comments 2010-07-20 (2)144me z� n COMMONWEALTH of VIRCjINIA DEPARTMENT OF TRANSPORTATION CHARLOTTESVILLE RESIDENCY OFFICE 701 VDOT WAY CHARLOTTESVILLE, VA 22911 GREGORY A. WHIRLEY COMMISSIONER July 20, 2010 Mr. Glenn Brooks Department of Engineering and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject: Site Review Meeting Comments July 22"0, 2010 site review meeting Dear Mr. Brooks: Below are VDOT's comments on the Site Plans for the July 22°0, 2010 Site Review Committee Meeting: SDP - 2010 -00051 Avemore IV Townhouses Final (Gerald Gatobu) .• No comments. SUB- 2010 -00081 Old Trail Block 4 Lots 2 -11 -Final (Megan Yani0os) This plat is missing a variable width clear zone easement which is to be located one foot behind the proposed sidewalk along lots 7, 8 and 9. + There are missing sight distance easement along lots 5, 7 and 9 that need to be shown on the plat. Please request the applicants provide a written description of revisions with re- submissions. If you have any questions or comments, please contact me prior to sharing these comments with the applicants. Sincerely, Joel DeNunzio, P.E. Staff Engineer VDOT Charlottesville Residency 434 - 293 -0011 WE KEEP VIRGINIA MOVING '*AW Alhemarie County Service Authority ng 6semnq TO: Gerald Gatobu FROM: Gary Whelan, Civil Engineer DATE: July 20, 2010 RE: Site Plan Technical Review for: Avemore Phase IV Townhouses -Final SDP201000051 TM 7813-3 -1 C The below checked items apply to this site. J 1. This site plan is within the Authority's jurisdictional area for: J A. Water and sewer B. Water only C. Water only to existing structure D. Limited service ✓ 2. An 8 inch water line is located on site. 3. Fire flow from, nearest public hydrant, located distant from this site plan, is Gpm + at 20 psi residual. J 4. An 8 inch sewer line is located on site. 5. An Industrial Waste Ordinance survey form must be completed. ✓ 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved. 9. No plans are required. J 10. Final water and sewer plans are required for our review and approval prior to granting tentative approval. 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. 13. City of Charlottesville approval for sewer. ✓ Comments: Three sets of water and sewer plans are to be delivered directly to the ACSA for review and approval. Phase Illb water dedication needs to be complete prior to final approval. The site plan does not show or incorrectly shows: meter locations water line size waterline locations sewer line size sewer line locations expected wastewater flows easements expected water demands 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthoriy.org