HomeMy WebLinkAboutSDP201000051 Correspondence 2010-07-27NOW, _
goWENGINEERS
SURVEYORS
PLANNERS
AssOC1ATEs
July 27, 2010
Mr. Gerald Gatobu, Principal Planner
Albemarle County
Department of Community Development
Zoning and Current Development
401 McIntire Road, North Wing
Charlottesville, VA 22902
Re: Avemore Phase IV- Townhouses Final Site Development Plan SDP - 2010 -00051
WWA # 209088.04
Dear Mr. Gatobu:
This letter is to document and respond to your review comments generated by County
staff for the above referenced project. The responses are to the comments dated July 19,
2010. Our responses areas follows:
Gerald Gatobu, Principal Planner
1. Comment: This proposal has been submitted as a final site plan prior to a
preliminary. The ordinance contemplates the approval of a preliminary site plan
prior to the submittal of a final site plan. However, by interpretation the
ordinance does allow the submittal of a final prior to approval of a preliminary.
No mechanism exists in the ordinance for the County to approve with conditions a
final site plan. Therefore, if the site plan does not have all the necessary
approvals to allow signature by the revision deadline the County will deny your
yMlication. You may request that this project be changed from a final to a^
preliminary site plan which may allow the County to approve the plan with
conditions or you may request that the County defer taking a formal action on
your application.
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
EM
`.kr`
2. Comment: Gross residential density: Please add the Gross residential density
(Du /Acre) on the site plan.
Response:
3. Comment: If a landscape plan is required, maximum amount ofpaved parking
and vehicular circulation areas Please add the maximum amount of paved
parking and vehicular circulation areas to the site plan. This figure will be used
to calculate the interior landscaping required.
Response:
4. Comment: If phasing is planned, phase lines and proposed timing of development.
Response:
5. Comment: [32.7.2.5] The commission or the agent may require provision for
and /or construction of travel lanes or driveways to serve adjoining properties.
The pavement of vehicular travel lanes or driveways designed to permit vehicular
travel on the site and from adjacent property and parking areas shall be not less
than twenty (20) feet in width. (32.5.7, 1980; Amended 5 -1 -87) Please construct
the travel lane (Avemore Pond Road) to the property line where the property
meets Wilton Countr Count Lane.
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
Page 2 of 11
`w.✓
6 Comment: [32.7.8.2] Is outdoor lighting is proposed? Ali P—h
—-agg plan is required
if outdoor lighting is proposed Outdoor lighting shall comply with the
requirements of section 4.17 of the Zoning Ordinance.
Response:
7. Comment: [32. S. 6. a] [4.11.3] Approval is required to reduce side setbacks from
1 S' to 10: Please contact the Fire and Rescue department and provide evidence
that Fire and Safety has approved the reduction of the side setback to 10'.
Response:
8. Comment: 32.7.2.8 Provision shall be made for sidewalks and pedestrian
walkways which will enable pedestrians to walk safely and conveniently between
buildings on the site and from the site to adjacent property. Please provide
sidewalks that will enable pedestrians to walk safely and conveniently between
buildings on the site and from the site to adjacent properties.
Response:
9. Comment: Interior landscaping: Exclusive of the requirements of section 32.7.9.7
(a) and (c), an area equal to five (S) percent of the paved parking and vehicular
circulation area shall be landscaped with trees or shrubs. (b) This shall include
one (1) large or medium shade tree per ten (10) parking spaces or portion
thereof, if five (S) spaces or more.
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
-.1.1-1.1-1-1-1 .. .. .. .. .... .. .................... I.I...".,..,....,..I..,..,..,..,..,..,..I -
Charlottesville ■ Lynchburg
Page 3 of 11
D
Response:
CM
10. Comment: Please show interior landscaping calculations at S (S) percent of the
paved parking and vehicular circulation area. Additionally please indicate the
number of large or medium shade trees per ten (10) parking spaces provided.
Response:
11. Comment: I could not locate one 1 (TI5) (White Oak)
Response:
12. Comment: There are 17 T (13) trees (London Plane Tree)
Response:
13. Comment: Please refer to Albemarle County's approved plant canopy
calculations list for the 10 year coverage totals. The 10 year coverage totals
shown in the plant list do not match what is shown on the landscape schedule on
sheet C-15. Please revise.
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 • Fax (434) 978 -1444
... ........................._._... -............................................._....._..._............. ...............................
Charlottesville ■ Lynchburg
Page 4 of 11
`*00 .r`
Phillip Custer - Engineering
1. Comment: The Zoning Department has determined that the plan is consistent
with the approved application plan.
Response:
2. Comment: The site plan cannot be approved until the WPO plan is approved. The
review of the WPO plan will be provided in a separate comment letter.
Response:
3. Comment: In order to subdivide the townhouse lots in the future, the applicant
must request a private street from the agent at the time of the final subdivision
plat application. [14 -233, 14 -234] The current subdivision ordinance requires the
private road to be constructed to VDOT standards or "an alternative standard
deemed adequate by the agent, upon recommendation of the county engineer ".
[14- 412.B] The plan does not appear to meet any VDOT standard. Through a
detailed discussion with the Chief of Current Development, it has been
determined that Avemore Pond Road will be reviewed to the travelway standards
of the Zoning Ordinance, 18 -4.12. Please make the following corrections to
satisfy engineering review with regard to the travelway /roadway within the site:
a. The applicant must build the Wilton arm Connection Road to the Property
Line. The horizontal and vertical alignments of the connector road must
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
Page 5 of 11
9M
*.re
work with the already constructed roadway from Wilton Farm. [18- 32.7.2,
18- 32.7.2.5]
Response:
b. Please provide anew estimate of the ADT on Avemore Pond Road under
the assumption that the connection to Wilton Farm is worked out. The
pavement section for Avemore Pond Road must be updated based on this
new ADT. [14- 412.B, 18-4.12.15a]
Response:
c. Perpendicular parking spaces must have a IOft width when a travelway of
20ft is provided. [18 -4.12]
Response:
d. All streets within the development areas require curbing, sidewalks, and
6ftplanting strips. Since the application plan was approved without
planting strips for this phase, planting strips will not be required.
However, sidewalks must be provided or a waiver of this design standard
must be approved by the Planning Commission. [14- 410.H, 14 -422, 18-
32.7.2.8]
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
Page 6 of 11
on
*400,
e. Please provide an autoturn exhibit showing the movement of afire engine
through Avemore Pond Road. [14- 412.B, 18- 32.5.6s]
Response:
f. The dedication of the access easement to the back of curb is not practical
for long term maintenance of the road /travelway. On the Village Green
side, please extend the easement at least one foot behind the curb. On the
outer edges, please provide a "6ft sidewalk and maintenance easement"
for the 5ft sidewalk that is necessitated by comment 3.d, or move the
easement line to lft behind the curb. [14- 412.B]
Response:
g. Please provide no parking signs along the Village Green side of Avemore
Pond. [18- 32.5.6s]
Response:
4. Comment: The county engineer must approve any drainage system (proposed or
existing) that exceeds open channel flow. The request has been delivered to the
county engineer. [Design Manual]
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville m Lynchburg
Page 7 of 11
OM
en
S. Comment: In the storm drain profiles, please show all of the sanitary sewer
lateral crossings.
Response:
6. Comment: Private storm drainage easements are needed over all pipes outside of
the road easement.
Response:
7. Comment: Driveways must be no steeper than 5 %. [18-4.12.15c]
Response:
8. Comment: All slopes steeper than 3:1 must have a low maintenance, non - grassed
groundcover specified. Examples of acceptable groundcovers can be found in
Table 3.37C of the VESCH.
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
. . . . . . . . . . . . . . . . . .. . . . .. . . . . . . ............. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........................ . .................... 1.11.1-1.1- .. . . . . . . . . .
Charlottesville ■ Lynchburg
Page 8 of 11
Joel DeNunzio, P.E. -VDOT
ACSA
No comment.
To be reviewed under separate cover.
Andrew Slack - Street Names /911
1. Comment: Approved.
Response:
James Barber — Fire and Rescue
1. Comment: Must comply with the Virginia Statewide Fire Prevention Code. Final
approval is subject to felid inspection and verification.
Response:
Jay Schlothauer - Inspections
1. Comment: No comments or conditions.
Response:
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
Page 9 of 11
Margaret Maliszewski - ARB
Comment: This townhouse development is located behind houses on Wilton farm
Road, as viewed from the Route 20 Entrance Corridor. Site sections previously
provided by the applicant show that the proposed townhouses are 40' high and
the houses on Wilton Farm Road are 32' high. Because the townhouses are to be
located behind the houses, and because the townhouses will not exceed twice the
height of the houses, this proposal qualifies for review as a county -wide
Certificate of Appropriateness. This type of review allows staff to complete the
review and approval without review at an ARB meeting. An ARB application and
submittal are still required, and approval of that application is required prior to
final site plan approval. The applicant can contact me with questions about the
submittal and review process. (Margaret Maliszewski, 296 -5832 x3276
mmaliszewski @albemarle. org)
Response:
I trust the above responses and plan changes properly address the outstanding
items. If you have any questions, please contact me.
Sincerely,
WW Associates, Inc.
r
r V4 ' "/'
David M. Jensen, P.E.
Vice President
Manager, Charlottesville Operations
3040 Avemore Square Place ■ Charlottesville, VA 22911
Telephone (434) 984 -2700 ■ Fax (434) 978 -1444
Charlottesville ■ Lynchburg
Page 10 of 11