HomeMy WebLinkAboutSDP200900100 Review Comments 2009-12-18Application #:SDP200900100-- Short Review Conn.'lents Project Name: PLEASANT GROVE BAPTIST CHURCH - FINAL Date Completed:12/18/2009 Reviewer:James Barber Fire Rescue Review Status:No Objection Reviews Comments: Must comply with the Virginia Statewide Fire Prevention Code. Final approval is subject to field inspection and verification. Date Completed:12/17/2009 Reviewer:Jay Schlothauer Inspections Review Status:No Objection Reviews Comments: 'Based on plans revised November 24, 2009. No further comments or conditions. Page: 1.00 County of Albemarle Printed On: Monday, December 28, 2009 Elizabeth Marotta From:Elizabeth Marotta Sent:Monday, December 28, 2009 11:12 AM To:AC00 @Comcast. net' Subject:FW: Pleasant Grove Final Attachments:PGBC -site plan application.pdf AC, Just checking in on the progress of getting me the application and fees. This is my first day back from the holiday break, and while I do not see any updates in County View indicating you have sent in the application or fees, it is p ssible you did it and it just has not been updated. Please let me know where you are with that. Thank you, Elizabeth From: Elizabeth Marotta Sent: Wednesday, December 16, 2009 12:24 PM Q,uID To: 'AC00 @Comcast.net' Cc: John Paul Diez; Carla Harris; Bill Fritz Subject: Pleasant Grove Final AC Good news, I found your site plans, and I will proceed with reviewing them and distributing them to all commenting department today, even without your completed application and check. I DO need your application and fees soon though! If possible, please have them to my office by next Monday, 5pm. Our Intake office has gone ahead and stared a new application number (SDP2009 -100) and project folder for your Final site plan application, which normally they wouldn't do without an application and all fees, so please try to get them to me as soon as possible! G ) I have attached the Application for Site Development Plans. Please fill it out and return it to me. I have gone ahead and checked the two applicable parts of the application and circled the fee amounts for you. Let me point out that the Tier III Groundwater Review is required. This involves you providing us with a Tier III groundwater assessment (pursuant to Albemarle County Code Chapter 17- Sections 400, 403, 405) and then submitting it to us for the review. I understand it might take you some time to get the report done and to us, but just go ahead and pay the fee now and that way there is no delay in us accepting the report once it is ready. In a separate email I will send you an example of a Tier III report that was done recently. Please let me know if you have any questions, Thank you, Elizabeth M. Marotta Senior Planner County of Albemarle Community Development Department 401 McIntire Road Charlottesville, VA 22902 434) 296 -5832 Ext. 3432 1 Elizabeth Marotta From:ac [AC00 @Comcast.net] Sent:Wednesday, December 16, 2009 4:23 PM To:Elizabeth Marotta Subject:Re: Pleasant Grove Final Thank you so much! AC Sent on the Now Network from my Sprint® BlackBerry From: "Elizabeth Marotta" <emarotta@albemarle.org> Date: Wed, 16 Dec 2009 12:23:50 -0500 To: <AC00 @Comcast.net> Cc: John Paul Diez <jdiez @,albemarle.org >; Carla Harris <CHARRIS @albemarle.org >; Bill Fritz <BFRITZ(&,albemarle.org> Subject: Pleasant Grove Final AC Good news, I found your site plans, and I will proceed with reviewing them and distributing them to all commenting department today, even without your completed application and check. I DO need your application and fees soon though! If possible, please have them to my office by next Monday, 5pm. Our Intake office has gone ahead and stared a new application number (SDP2009 -100) and project folder for your Final site plan application, which normally they wouldn't do without an application and all fees, so please try to get them to me as soon as possible! I have attached the Application for Site Development Plans. Please fill it out and return it to me. I have gone ahead and checked the two applicable parts of the application and circled the fee amounts for you. Let me point out that the Tier III Groundwater Review is required. This involves you providing us with a Tier III groundwater assessment (pursuant to Albemarle County Code Chapter 17- Sections 400, 403, 405) and then submitting it to us for the review. I understand it might take you some time to get the report done and to us, but just go ahead and pay the fee now and that way there is no delay in us accepting the report once it is ready. In a separate email I w'll send you an example of a Tier III report that was done recently. (' G, , utiout - t- t N vqC, (Ili tk t -Zdfk Please let me know if you have any questions, Thank you, 4 6 ht r " -- c)4I4 'I - Elizabeth M. Marotta C La L „ k ,. e 1 (, ' Senior Planner of Albemarle Community Development Department TV 1- li1S1'crtt 1 4+'+.tc- 401 McIntire Road Charlottesville, VA 22902 vv Loci 61 f C ett a) ' 434) 296 -5832 Ext. 3432 1 J 1 _n r1 t/ ' j 1 J rc fli'GITJ COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 January 8, 2010 AC Shelton ACS Construction 711 Hospital St, Suite 12 Richmond, VA 23219 RE: SDP - 2009 -100 Pleasant Grove Baptist Church- Final Dear Sir: Your final site plan has been distributed to the reviewing agencies identified on the preliminary approval letter, with the exception of the Health Department. Below, please find Current Development- Planning, Inspections, and Fire and Rescue's comments. Additional comments from reviewing departments and agencies may be forthcoming. Please review the comments and revise the plan of the proposed development accordingly. Your revisions should be resubmitted directly to the reviewer who commented along with the attached revised application submittal form. Once all comments are addressed and the plan meets the requirements of the Albemarle County Code, tentative approval will be granted. After all reviewing agencies grants tentative approval you will be required to submit one complete set of plans for final tentative approval. Once tentative final approval is granted you will be notified to submit the final site plan for signature. Do not submit plans for signature until you verify with the planner that you may submit the mylars for signing. When we request plans for signature, we will require two signed and sealed mylar copies of the site plan (the original and a copy for County records) and two paper copies. Once submitted the plan should be signed within one week.t,. pet ek Please note that as of today we have still not received a copy of your final site plan application or applicable fees. You must submit these before any plans will be signed. If you have any questions about the comments of a specific agency please contact that agency directly. If you have any questions about the review process please feel free to contact me. Current Development Comments: 1. 32.5.6.a] Zoning: a. AIA- This property is in the Airport Impact Area. While "Air" was added to the plan set, please spell out Airport Impact Area. b. This property is subject to ZMA200600010 and all conditions of SP200600024; a list of all conditions must be provided on the plans. 2. 32.5.6.a] Setback lines: 1 a. Include legend for any abbreviations used, ie. SBL, etc. Please note that the setback line is labeled "25' setback line"' so the additional "25' SBL" notation is not required. 3. 32.5.6.a] Vicinity map is deceiving, as the property immediately behind this site is not the airport: it is a residential neighborhood. While property information was added to the vicinity map. the map still indicates the airport is to the northwest of the site and this is not accurate. Revise vicinity sketch so that all landmarks are accurately depicted. 4. 32.5.6.b] [32.5.6.e] [32.5.6.p] Landscaping: a. Revise landscape calculations, as 5% of 19,600 is 980, not 960. 5. 32.5.6.b] [32.6.6.g] Method of parking calculations is being reviewed by Zoning. Additional comments may be forthcoming. 6. 32.5.6.e] Show existing treeline. Staff does not that proposed is shown. but existing must also be shown and clearly labeled. 7. 32.5.6.p] Landscape plan- Please be aware that what gets approved on the plan is the only landscaping that is permitted. What gets installed in the field must match what is approved on the plan. 8. 32.5.6.f] This property is in a water supply protection area: explicitly provide which reservoir watershed applies (South Fork Rivanna- above reservoir). Be sure to indicate that it is above the reservoir on the cover sheet with Note #8. 9. 32.5.6.k] [32.6.6j] Water/ Sewer: a. Drainfield location must be approved by Health Department. Please submit soils work /evidence of previous approvals to this 75. [32.5.6.n] Note on cover sheet says 50 parking spaces are provided, yet plans show 51. Please address discrepancy. 11. [32.5.6.r] Dimension on the plans the travelways, parking spaces, walkways, and building footprint. 2 parking space from the left on the southernmost row of parking appears to be only 8' wide, but must be a minimum of 9'. Travelway on southern half of the site appears to be only 23'. While a note is provided that all spaces are a minimum of 9' and travelways a minimum of 24', the scaled drawing must show this to be true. Please revise as necessary. Also, please dimension 9' walkway in front of the building. 12. [32.6.6.f] Provide signature panel on the cover sheet that provides space for signature by each commenting department. 13. [32.6.6.i][32.7.9] Lighting plan is required. Provide required lighting note on the cover sheet: Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one -half footcandle. 14. [Comments] Sheet 3 of plan set dated 10/14/09: a. What is the "18 "" curb opening" callout referring to? Provide note or details to clarify. b. Clearly call out limits of clearing. [32.5.6.p] Because it appears trees are to remain on the site, a Conservation Checklist is required to be completed and signed and provided on the landscape plan. While it is provided on the plans, it is not complete or signed. The checklist is available online at: http: / /www.albemarle.ore/ upload /images /forms center /departments /community_ development /forms /applications /Check( ist_Conservation_Plan.pdf Inspections: 1. No objection Fire and Rescue: I. No objection 2 Please contact me at 296 -5832 x3432 if you have questions or require additional information. Sincerely, Elizabeth M. Maro Senior Planner Zoning & Current Development File: SDP - 2009 -75 Cc: Pleasant Grove Baptist Church 3 i cf ALjj 1 04g r ,4 IMP COUNTY OF ALBEMARLE De rtment of Community Development 3 <.McIntire Road, North Wing t Char ottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 January 8, 2010 AC Shelton ACS Construction 71 1 Hospital St, Suite 12 Richmond, VA 23219 RE: SDP- 2009 -100 Pleasant Grove Baptist Church- Final Dear Sir: Your final site plan has been distributed to the reviewing agencies identified on the preliminary approval letter, with the exception of the Health Department. Below, please find Current Development- Planning, Inspections, and Fire and Rescue's comments. Additional comments from reviewing departments and agencies may be forthcoming. Please review the comments and revise the plan of the proposed development accordingly. Your revisions should be resubmitted directly to the reviewer who commented along with the attached revised application submittal form. Once all comments are addressed and the plan meets the requirements of the Albemarle County Code, tentative approval will be granted. After all reviewing agencies grants tentative approval you will be required to submit one complete set of plans for final tentative approval. Once tentative final approval is granted you will be notified to submit the final site plan for signature. Do not submit plans for signature until you verify with the planner that you may submit the mylars for signing. When we request plans for signature, we will require two signed and sealed mylar copies of the site plan (the original and a copy for County records) and two paper copies. Once submitted the plan should be signed within one week. Please note that as of today we have still not received a copy of your final site plan application or applicable fees. You must submit these before any plans will he signed. If you have any questions about the comments of a specific agency please contact that agency directly. If you have any questions about the review process please feel free to contact me. Current Development Comments: 32.5.6.a] Zoning: A1A- This property is in the Airport Impact Area. While "Air" was added to the elan set, please spell out Airport Impact Area. This property is subject to ZMA200600010 and all conditions of SP200600024; a list of all conditions must be provided on the plans. 2. 132.5.6.a] Setback lines: 1 r , ' include legend for any abbreviations used, ie. SBL, etc. Please note that the setback line is labeled "25' setback line" so the additional "25' SBL" notation is not required. ' .51 rte. JJ 32.5.6.a] Vicinity map is deceiving, as the property immediately behind this site is not Ar the airport; it is a residential neighborhood. While property information was added to the vicinity map, the map still indicates the airport is to the northwest of the site and this is not accurate. Revise vicinity sketch so that all landmarks are accurately depicted. - , I''I 32.5.6.b] [32.5.6.e) [32.5.6.p] Landscaping: a. Revise landscape calculations, as 5% of 19,600 is 980, not 960. 9 5. 32.5.6.b] [32.6.6.g] Method of parking calculations is being reviewed by Zonings D Additional comments may be forthcoming. 32.5.6.e] Show existing treeline. Staff does not2hat proposed is shown, but existing usi iyJ' Li also be shown and clearly labeled. tt! 4 p [ 32.5.6.p ] Landscape plan- Please be aware that what gets approved on the plan is the only landscaping that is permitted. What gets installed in the field must match wJat is tt v pproved on the plan. 0.._ e t ei2.` ek_ t']t'(t - t K l.. gat -Z 1'"'i V 32.5.6.f] This property is in a water supply protection area; explicitly provide which reservoir watershed applies (South Fork Rivanna- above reservoir). Be sure to indicate that it is above the reservoir on the cover sheet with Note #8. 9 132.5.6.k] [32.6.6.j] Water / Sewer:r1 vutl, .Cilit cj ci Ho (. ri''``1v' a. Drainfield location must be approved by Health Deptment. Please submit soils CL.rtt'1 work/evidence of previous approvals to this office. ' 32.5.6.n] Note on cover sheet says 50 parking spaces are provided, yet plans show 51. Please address discrepancy. 11. [32.5.6.r] Dimension on the plans the travelways, parking spaces, walkways, and building 7 t footprint. 2 parking space from the left on the southernmost row of parking appears to be only 8' wide, but must be a minimum of 9'. Travelway on southern half of the site appears to be only 23'. While a note is provided that all spaces are a minimum of 9' and tr elways a minimum of 24', the scaled drawing must show this to be true. Please revise s necessary. Also, please dimension 9' walkway in front of the building. 32.6.6.f] Provide signature panel on the cover sheet that provides space for signature by e ch commenting department. 326.6.i][32.7.9] Lighting plan is required. Provide required lighting note on the cover i sheet: Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial WP 2 lumens shall be a full cutoff luminaire. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one -half footcandle.y 14. [Comment, ] Sheet 3 of plan set dated 10/14/09: hat is the "18" curb opening" callout referring to? Provide note or details to clarify. s • P," Clearly call out limits of clearing. [32.5.6.p] Because it appears trees are to o remain on the site, a Conservation Checklist is required to be completed and 1L signed and provided on the landscape plan. While it is provided on the plans, it is C c tl'tl not complete or signed. The checklist is available online at: Imp:fl,v,vN.alhcnr,irl con (Juploaci/ iin_ wrs /torn) /ckar_ nts/coniniiinit clevclopnw alt /lornisiapplic aliens /Chec_idistC_n1 i'l_ii,pcll N Inspections: 1. No objection it r 2 V VI Fire and Rescue: CV C C, C,,, I. j'[ 1. No objection 2 Please contact me at 296 -5832 x3432 if you have questions or require additional information. Sincerely, Elizabeth M. Marotta, Senior Planner Zoning & Current Development File: SDP - 2009 -7.5 Cc: Pleasant Grove Baptist Church 3 oFAL4( Verik IRGI1 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 - 4126 Project:SDP - 200900100 & WP0200900070, Pleasant Grove — Final Site Plan Plan preparer:AC Shelton (ac00@comcast.net) Owner or rep.:Pleasant Grove Baptist Church C/O James E Thomas Date received:16 December 2009 Date of Comment: 13 January 2010 Engineer:John P. Diez — Engineering Technician The Final Site Plan for Pleasant Grove, received on 16 December 2009 has been reviewed. The plan cannot be approved as submitted and will require the following corrections before approval can be granted: A. General Review Comments 1. A11 slopes 25% and over (critical slopes by County Zoning Ordinance) must be shaded [1 8- 32.6.6] 2. Please specify on the plans that "All proposed slopes steeper than 3:1 must be provided with low maintenance (not grass) ground cover. 3. All entrances must have VDOT designations (PE -1, CG -9a, etc.) 4. Please provide unobstructed sight distance triangles at the entrance. 5. 12.5' minimum radii at the entrance (or per VDOT requirements, typically 25' -35') must be provided. 6. VDOT approval must be obtained for any plan affecting public right -of -way. 7. Some parking areas exceed the 5% grade minimum. Please revise. 8. Parking width x depth x aisle width is 9'x18'x24' or 10'x18'x20' (where a 2' grass overhang is possible, parking spaces can be 16' deep per detail 2 of the Design Standards Manual). 18- 4.12.16] 9. Sidewalks abutting parking must be a minimum of 6' wide (exclusive of curb), or bumper blocks must be provided. Please refer to the Design Standards Manual. 10. Sidewalks must be a minimum of 5' wide, exclusive of curb. Please refer to the Design Standards Manual. 11. Please provide a pavement design detail. 12. Please show all existing utilities on the plans. 13. Please provide a tree survey showing existing trees within the No Disturbance Zones. B. SWM Plan Review Comments 14. Manufactured pre- fabricated water quality facilities must have a written approval from the manufacturer. 15. A completed copy of the standard stormwater maintenance agreement and fee for recordation for any stornwater management facilities must be submitted. [17 -304E] 16. Please provide a drainage profile for the proposed stormwater pipes. 17. Please provide details and computations for the control riser for storm water detention. 18. Please provide coefficient and time of concentration for each drainage area. 19. Please provide an adequate channel analysis (MS -19). C. Erosion and Sediment 'Control Review Comments 20. Please provide an Erosion and Sediment Control Narrative. 21. It appears that the sediment trap will not capture most of the runoff during construction. Engineering recommends that the sediment trap be moved to the south side of the site (by the proposed SWM outlet). In addition, please provide a diversion dike along the southeast side of the site to capture and direct the runoff to the sediment trap. 22. Please provide details and computations for the sediment trap. 23. The diversion dike on the northeast side of the site is not necessary; Please remove. 24. Silt fence must not be installed across contours. Please remove the silt fence on the northeast side of the site. 25. Please provide dust control (DC) on the plans. 26. Please provide temporary and permanent seeding (TS, PS) on the plans. 27. Please provide a stockpile and staging area. 28. Please provide a construction sequence. 29, Please install outlet protection to all proposed outlets. O I rl r o COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project:SDP - 2009 -00de & WPO20090I'. ZP, Pleasant Grove — Final Site Plan Plan preparer:AC Shelton (ac00 @comcast.net) Owner or rep.:Pleasant Grove Baptist Church C/O James E Thomas Date received:16 December 2009 Date of Comment: 13 January 2010 Engineer:John P. Diez — Engineering Technician The Final Site Plan for Pleasant Grove, received on 16 December 2009 has been reviewed. The plan cannot be approved as submitted and will require the following corrections before approval can be granted: A. General Review Comments 1. All slopes 25% and over (critical slopes by County Zoning Ordinance) must be shaded [18- 32.6.6] 2. Please specify on the plans that "A11 proposed slopes steeper than 3:1 must be provided with low maintenance (not grass) ground cover. 3. All entrances must have VDOT designations (PE -1, CG -9a, etc.) 4. Please provide unobstructed sight distance triangles at the entrance. 5. 2.5' minimum radii at the entrance (or per VDOT requirements, typically 25' -35') must be provided. 6. VDOT approval must be obtained for any plan affecting public right -of -way. 7. Some parking areas exceed the 5% grade minimum. Please revise. 8. Parking width x depth x aisle width is 9'x18'x24' or 10'x18'x20' (where a 2' grass overhang is possible, parking spaces can be 16' deep per detail 2 of the Design Standards Manual). 18- 4.12.16] 9. Sidewalks abutting parking must be a minimum of 6' wide (exclusive of curb), or bumper blocks must be provided. Please refer to the Design Standards Manual. 10. Sidewalks must be a minimum of 5' wide, exclusive of curb. Please refer to the Design Standards Manual. Please provide a pavement design detail. 12. Please show all existing utilities on the plans. U lG j 13. Please provide a tree survey showing existing trees within the No Disturbance Zones. 1 ID 04 t B. SWM Plan Review Comments 14. Manufactured pr - fabricated. water quality facilities must have a written approval from the manufacturer. 15. A completed copy of the standard stolniwater maintenance agreement and fee for recordation for any stormwater management facilities must be submitted. [ 17 -304E] 16. Please provide a drainage profile for the proposed stormwater pipes./ 17. Please provide details and computations for the control riser for storm water detention. 18. Please provide coefficient and time of concentration for each drainage area. 19. Please provide an adequate channel analysis (MS -19). C. Erosion and Sediment Control Review Comments 20. Please provide an Erosion and Sediment Control Narrative. 21. It appears that the sediment trap will not capture most of the runoff during construction. Engineering recommends that the sediment trap be moved to the south side of the site (by the proposed SWM outlet). In addition, please provide a diversion dike along the southeast side of the site to capture and direct the runoff to the sediment trap. 22. Please provide details and computations for the sediment trap. 23. The diversion dike on the northeast side of the site is not necessary; Please remove. 24. Silt fence must not be installed across contours. Please remove the silt fence on the northeast side of the site. 25. Please provide dust control (DC) on the plans. 26. Please provide temporary and permanent seeding (TS, PS) on the plans. 27. Please provide a stockpile and staging area. 28. Please provide a construction sequence. 29. Please install outlet protection to all proposed outlets. Elizabeth Marotta From:Elizabeth Marotta Sent:Friday, February 19, 2010 5:30 PM To:AC' Subject:planning comments for plans dated 2/10/10 Attachments:CD2_emm_sdp09- 100_comments.pdf AC, Please see attached for planning's comments for plans dated revised 2/10/10. Let me know if you have any questions, Thank you, Elizabeth M. Marotta Senior Planner County of Albemarle Community Development Department 401 McIntire Road Charlottesville, VA 22902 434) 296 -5832 Ext. 3432 gMJ TA/O rt CerAhl-0/11S 11 HO ai akvavok r &sct.rocu_ckluw F ALA I Ill ''o4N i 'LRGil COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 February 19, 2010 AC Shelton ACS Construction 711 Hospital St, Suite 12 Richmond, VA 23219 RE: SDP - 2009 -100 Pleasant Grove Baptist Church- Final Dear Sir: Your final site plan as revised 2 /10 /10 has been reviewed by Current Development- Planning; see comments below. Additional comments from reviewing departments and agencies may be forthcoming. Please review the comments and revise the plan accordingly. Your revisions should be resubmitted directly to me along with the attached revised application submittal form. Once all comments from all commenting departments /agencies are addressed and the plan meets the requirements of the Albemarle County Code, tentative approval will be granted. After tentative approval is granted you will he required to submit one complete set of plans for final tentative approval. Once tentative final approval is granted you will be notified to submit the final site plan for signature. Do not submit plans for signature until you verify with the planner that you may submit the mylars for signing. When we request plans for signature, we will require two signed and sealed mylar copies of the site plan (the original and a copy for County records) and two paper copies. Once submitted the plan should be signed within one week. Current Development Comments: 32.5.6.e] Show existing treeline. Staff does note that it is possible the treeline is off the property. If this is the case, provide a note on the cover sheet that "site is currently wooded." VA ok ' i` -2 ' OV-" 2. 32.5.6.p] Limits of clearing must be coordinated with limits of disturbance. Please note that to clear, or to access an area to clear, is to disturb. Therefore your proposed limits of 3,i disturbance must be revised to at least the limits of clearing. Because trees are to remain on the site, a Conservation Checklist is required to be completed and signed and provided on the landscape plan. While it is provided on the plans and signed, it is not completed. Please go through the checklist, ensure each of those items is addressed on the plans, and check it off on the checklist on the plans. e-' Please note that landscaping (trees) appears to be proposed over /adjacent to electric lines. YC l Likely there is an easement associated with these lines. You must either grant permission from the easement holder to plant in their easement, or, you may revise the proposed plan t4 V1 tv so that landscaping is not proposed in /around the electric lines and (likely) associated cii4) ,D t. 1 easement Please contact me at 296- 5832 x3432 if you have questions or require additional information. Sincerely, Elizabeth M. Marotta, S: for Planner Zoning & Current Development File: SDP - 2009 -75 Cc: Pleasant Grove Baptist Church ov AL .6,t 1'41r1 RGirIV' COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project:SDP - 200900100 & WP0200900070, Pleasant Grove — Final Site Plan Plan preparer:AC Shelton (ac00 @comcast.net) Owner or rep.:Pleasant Grove Baptist Church C/O James E Thomas Date received:16 December 2009 Rev. 1:16 February 2010 Date of Comment: 13 January 201 Rev. 1:23 February 2010 Engineer:John P. Diez — Engineering Technician The Final Site Plan for Pleasant Grove, received on 16 February 2009 has been reviewed. The plan cannot be approved as submitted and will require the following corrections before approval can be granted: A. General Review Comments 1. All slopes 25% and over (critical slopes by County Zoning Ordinance) must be shaded [18- 32.6.6] Rev. 1) Comment has not been addressed. Please shade all existing critical slopes that are shown on the plan. 3. All entrances must have VDOT designations (PE - 1, CG - 9a, etc.) Rev. 1) Comment has not been addressed. Please provide the VDOT designation that connects the proposed entrance with State Route 743. 4. Please provide unobstructed sight distance triangles at the entrance. Rev. 1) Comment has not been addressed. The sight distance triangles must be shown in plan view to verify whether the sight distance profile is accurate. 8. Parking width x depth x aisle width is 9'x18'x24' or 10'x18'x20' (where a 2' grass overhang is possible, parking spaces can be 16' deep per detail 2 of the Design Standards Manual). 18- 4.12.16] Rev. 1) Comment has not been addressed. The northeast curb on the southeast parking lot can be moved 12" inches towards the northeast to achieve the required parking space dimensions. B. SWM Plan Review Comments 15. Please provide a drainage profile for the proposed stormwater pipes. Rev. 1) Conzznent has been addressed. Though, the profile may need to be updated based on other comments within this letter. 16. Please provide details and computations for the control riser for storm water detention. Rev. 1) The detention plan as provided by the applicant is not satisfactory. First of all, in the plan and calculations, I could not find the pre - development rates which the detention facility must be designed to meet. Using a pre - development drainage area of 1.03acres, C -value of 0.3, and a time of concentration of 15 minutes, I computed the 2 and 10 year discharge rates to be 1.05cfs and 1.40cfs, respectively. Second, the calculations did not match the plan in many instances (outlet structure of Reservoir 2, starting elevation of the pipes, the volume pipe system appears to be over - estimated, etc.). The time of concentration for hydrograph 1 and 3 is too high. The critical storm does not appear to be routed. Based on this comments, additional conznzents will likely be necessary. By having two detention pipes in series, proving detention compliance becomes much more difficult and time consuming. I reconznzend simplifying the system by reducing the pipe between 2 and 3 to 15 ", make structure 3 a VDOT Standard End Section, and providing the detention volume upstream of structure 2. I found that by adding a 5" orifice plate on the inlet end of the 15" pipe from structure 2 and converting the 42 "pipe to 48" as well as adding 2 additional 70ft sections of 48 "pipe, detention will be met. This is assuming a 0.5% grade on the detention system. 18. Please provide an adequate channel analysis (MS - 19). Rev. 1) As a courtesy to the applicant, County personnel made a visit to the site and concluded that MS -19 will be addressed once the following is shown in the plan: Detention of the 2 and 10 year storms to pre - development flows, Construction of a properly -sized channel from the drainage system outlet on site to the existing VDOT culvert (Permission from the adjacent owner will be required), and Repair of the existing VDOT inlet structure. C. Erosion and Sediment Control Review Comments 19. Please provide an Erosion and Sediment Control Narrative. Rev. 1) Comment has not been addressed. Please refer to VI -24 of the Virginia Erosion and Sediment Control Handbook (VESCH) for a detailed sample of the E &S Narrative. 21. Please provide details and computations for the sediment trap. Rev. 1) A trap has been provided in the correct location but it is not large enough for the drainage area. It appears that the proper trap size can be achieved with the addition of a retaining wall and /or the use of 2:1 on the southeastern slopes. If 2:1 slopes are used, please specify a low maintenance, non -grass groundcover. The southern travelway can also be reduced to 24ft. 23. Silt fence must not be installed across contours. Please remove the silt fence on the northeast side of the site. Rev. 1) Comment has not been addressed. Please remove the silt fence along the northeast side of the site and replace it with diversion dike. 24. Please provide dust control (DC) on the plans. Rev. 1) Comment has not been addressed. 25. Please provide temporary and permanent seeding (TS, PS) on the plans. Rev. 1) Comment has not been addressed. 26. Please provide a stockpile and staging area. Rev. 1) Comment has not been addressed. 27. Please provide a construction sequence. Rev. 1) Comment has not been addressed. 29. Please provide inlet protection (IP) to the culvert of the proposed entrance. UDC, - app./LA t' I Lf- cf.:,F Elizabeth Marotta From:DeNunzio, Joel D., P.E. JoeI.DeNunzio VDOT.vir inia. ov a(L L 1, ( , 1" Sent:Wednesday, February 24, 2010 9:59 AM To:Elizabeth Marotta 0 . S lI 1 C, Subject:SDP - 2009 -00100 Pleasant Grove Baptist Church SDP - 2009 -00100 Pleasant Grove Baptist Church Elizabeth,f I received a revised pla heet 3 of 8 dated 2 -22 -2010 for the above referenced project. This sheet addresses my concerns with the prop ed I have no ail_ition.a.Lcom+nents. - Please let the applicant know that prior to construction, they must btain a Land Use Permit for the VDOT Charlottesville office. Thanks 1 Cs. ` A L C V rem Se cry Joel V r .i I i) e. 1711 di( <;f1-1 tie_e /1. Joel DeNunzio, P.E.s, ti0 E , ( VI 1,x'1`.' - Staff Engineer 434 -293 -0011 Ext. 120 ioel.denunzioc vdot.virginia.gov From: DeNunzio, Joel D., P.E. Sent: Wednesday, January 20, 2010 2:58 PM To: 'Elizabeth Marotta' Subject: SDP - 2009 -00100 Pleasant Grove Baptist Church Elizabeth, I have reviewed the above site plan and it does not appear that the comments below have been addressed. Please ask the applicant to address the comments and provide a written response of any plan revisions. Please let me know if you have any questions. Thanks Joel From: DeNunzio, Joel D., P.E. Sent: Tuesday, November 24, 2009 10:53 AM To: 'Elizabeth Marotta' Subject: SDP - 2009 -00075 Pleasant Grove Baptist Church SDP - 2009 -00075 Pleasant Grove Baptist Church Elizabeth, 1 I have reviewed the above site plan and have the following comments: Show sight lines in accordance with VDOT's Road Design Manual, Appendix G, page G -31. The bank to the right of the entrance may have a vertical conflict. The entrance pipe needs to be moved away from the road and back behind the proposed radii at the entrance to eliminate clear zone, erosion and maintenance issues. Show the outlet velocity on the pipe and any needed outlet protection. Show an entrance profile in a accordance with the requirements of Appendix G of the Road Design Manual. Use CG -7 curb and gutter within the Right of Way of Route 743. Pavement structure within the Right of Way of Route 743 must be equivalent to the structure of the road in accordance with the requirements for a commercial entrance. If you have any questions ,please contact me. Thanks Joel Joel DeNunzio, P.E. Staff Engineer 434 - 293 -0011 Ext. 120 ioel.denunzio@ vdot.virginia.gov 2 John Pau! Diez From:John Paul Diez Sent:Thursday, February 25, 2010 9:48 AM To:downingsurveys @aol.com'; 'ac00 @comcast.net' Cc:Philip Custer; Marcia Joseph Subject:RE: Pleasant Grove CHurch - SDP200900100 / WPO200900070 Attachments:VDOT Sight Distance Info.pdf Melvin: The following is a reply to your e -mail of 02/24/10 1. Slopes exceeding 25% Will shade , these slopes are off site.) 3. Entrance VDOT requested CG -7, shown on sheet 3) 4. Sight Triangles Triangles shown on sheet 6, profile view sheet 8, VDOT has approved) 8. Parking Width curb to curb is 135', 15 spaces X 9' = 135') 15.Drainage profile See item 16) 16. Storm Detention Our storm detention plan as shown on the plans is adequate as provided in the Hydraflow Hydrographs previously furnished your office, we will have to have further discussions about this, how do you dictate the detention method. Pre & post development calculations are on the drainage area plan) 18. MS -19 According to The Virginia Stormwater Mangement Handbook you either have to meet MS -19 requirements or provide detention. We are providing detention) 19. Narrative Shown on erosion and sediment control plan) 21.. Sediment Trap will provide adequate capacity) 23. Silt Fence The erosion and sediment control handbok does not say that you cannot put silt fence across contours , is this a county requirement? ) 24 Dust Control Will provide note) 25. Seeding Shown on Sheet 2) 1 26. Stockpile will show area) 27.Construction Sequence shown in Narrative) 28. IP on entrance pipe Will provide) johr Diaz Engineering Technician Dept. of Community Development 434) 296 -5832 Ext. 3025 From: downingsurveys @aol.com [mailto:downingsurveys @aol.com] Sent: Wednesday, February 24, 2010 3:29 PM To: John Paul Diez Subject: Re: Pleasant Grove CHurch - SDP200900100 / WP0200900070 Dear John: The following is a reply to your e -mail of 02/23/10 ( The attachment) with the comments numbered respectfully. 1. Slopes exceeding 25% Will shade , these slopes are off site.) 3. Entrance VDOT requested CG -7, shown on sheet 3) 4. Sight Triangles Triangles shown on sheet 6, profile view sheet 8, VDOT has approved) 8. Parking Width curb to curb is 135', 15 spaces X 9' = 135') 15.Drainage profile See item 16) 16. Storm Detention Our storm detention plan as shown on the plans is adequate as provided in the Hydraflow Hydrographs previously furnished your office, we will have to have further discussions about this, how do you dictate the detention method. Pre & post development calculations are on the drainage area plan) 18. MS -19 According to The Virginia Stormwater Mangement Handbook you either have to meet MS -19 requirements or provide detention. We are providing detention) 19. Narrative Shown on erosion and sediment control plan) 21.. Sediment Trap will provide adequate capacity) 23. Silt Fence The erosion and sediment control handbok does not say that you cannot put silt fence across contours , is this a county requirement? ) 24 Dust Control Will provide note) 2 25. Seeding Shown on Sheet 2) 26.Stockpile will show area) 27.Construction Sequence shown in Narrative) 28. IP on entrance pipe Will provide) Will call you to discuss these items further . Melvin Spain 804) 798-6795 Original Message From: John Paul Diez <jdiez @albemarle.org> To: ac00 @comcast.net; downingsurveys @aol.com Cc: Marcia Joseph <marcia481 @earthlink.net >; Philip Custer <pcuster @albemarle.org> Sent: Tue, Feb 23, 2010 3:37 pm Subject: Pleasant Grove CHurch - SDP200900100 / WPO200900070 AC and Melvin, Engineering has reviewed the plans for Pleasant Grove. Attached, you will find the comments that need to be addressed. Please feel free to contact me should you have any questions. The required resubmittal fees of $600 for the E &S and SWM reviews were not submitted with this set of plans. Please submit these fees at the time of your next resubmittal, along with the additional $600 fee for the new review. This will be a total of $1200. Thank you, John i z Engineering Technician Dept. of Community Development 434) 296 -5832 Ext. 3025 3 Philip Custer From:Philip Custer Sent:Monday, March 08, 2010 4:40 PM To:downingsurveys @ aol.com'; ac00 @comcast.net; joel.denunzio @vdot.virginia.gov Cc:John Paul Diez; Elizabeth Marotta Subject:RE: pleasant grov The elevation at entrance (615.2) is too high. The elevation of the roadway is around 612. This ultimately creates a 30°%o slope at the entrance. A more realistic elevation to use in the analysis is 612.5. The eye height would then be 616. I also noticed that in previous revisions the entrance was located at station 21 +00 along Earlysville Road. In the latest two revisions to the sight distance profile, entrance was moved to Sta. 18 +35, a difference of265ft. By my measurements, the entrance should actually be closer to 20 +50 (having moved only — 50ft). I also don't think the entrance is on the other side of the peak of Earlysville Rd. Please clarify. Also, the sight profile is not shown accurately. Please see the attached pdf. In 081107.pdf, I found the sight distance line to cross the 617, 618, and almost the 619 contour line while 081107 -2 shows 616 as being the highest contour line crossed. More grading is necessary. The scale of the plan view document is 40ft per inch, assuming the entrance is actually 30ft wide as dimensioned. From: downingsurveys @aol.com [mailto:downingsurveys @aol.com] Sent: Monday, March 08, 2010 3:49 PM To: Philip Custer; ac00 @comcast.net; joel.denunzio @vdot.virginia.gov Subject: pleasant grov Phil: I have revised the grading plan and sight profile that we discussed. Mr. Denunzio of VDOT has agreed that we can eliminate the entrance culvert. I have not revised the outfall drainage plan that we discussed, will do so and forward an additional pdf. Please advise Melvin 1 Elizabeth Marotta From:Philip Custer Sent:Thursday, March 11, 2010 4:08 PM To:downingsurveys @aol.com; ac00 @comcast.net; joel.denunzio @vdot.virginia.gov; Marcia Joseph Cc:John Paul Diez; Elizabeth Marotta Subject:RE: pleasant grove Attachments:3 -11 -2010 redlines.pdf; 3 -8 -2010 Phil to Downing Email.pdf Good afternoon, v.\ eL4/1 u t ff a I have reviewed the latest revision to the sight distance exhibits. The plan appears to show the appropriate amount of grading into the roadside embankment and the sight distance profile confirms this. This ultimately will be checked in the field through the VDOT entrance permit process. However, before the plan can be approved the following changes should be made to the plan: in the profile, the finish grade should be no higher than 612.5 (as mentioned in my email on Monday) and t he height of eye should be 616, (It should be noted that even the 612.5 elevation is likely too high if a VDOT standard entrance is to be constructed, which is even more of a concern since the entrance culvert was removed.) eliminate the top of curb callout next to the wall eliminate the 614 contour across the entrance change the finish grade spot elevation to 612.5, change the height of eye elevation to 616 show the grading of the swale from the outlet of the onsite drainage system to the VDOT culvert that goes under Earlysville Rd. With the changes above, the plan will be close enough that everything can be straightened out in the field. The biggest concern will be establishing a low spot in the entrance as called out in the VDOT Std. PE -1. Also, more linear feet of retaining wall can also be expected (see drawing). VDOT may want to see more refined grading at the entrance, because of the removal of the culvert, to ensure that water does run along the seam of the entrance and the edge of the westbound travel lane. Once disturbance to the adjacent property is authorized, please pass this approval on to the county. I'd be happy to speak to the property owner if necessary. Please let me know if you have any questions. Elizabeth is currently reviewing the set AC dropped off on Monday. I will meet with John tomorrow or Monday to discuss the status of the remaining engineering comments after looking over the plan submitted Monday 3/8. Phil From: downingsurveys @aol.com [mailto:downingsurveys @ aol.com] Sent: Thursday, March 11, 2010 11:26 AM To: Philip Custer; ac00 @comcast.net; joel.denunzio @vdot.virginia.gov Subject: Fwd: pleasant grove Original Message From: downingsurveys @aol.com 1 Sent: Thu, Mar 11, 2010 10:08 am Subject: pleasant grove Phillip: This submittal is in response to your e -mail of Mar. 8 th. The revised entrance sight line elev has been lowered to 617 The grading has been revised to reflect this change. However, the grading will exceed the limits of our field taken topo on the adjacent parcel to the west. I have provided additional stationing to clarify your comments about the entrance relationship to Earlysville road. I have also revised the location of the outfall ditch on the east side of the parcel for your review. Melvin 2 1 C. 0 I \k \ '„ k ' 1 1 1 , \ 1 k \ Ikkk% kk kk,%; k,,,, k%, k 1 \ \ ' s ,, \ k ‘ , ' k , k \ , , \ 1 \ \ \ \ 1 , 1 I 3 . 1\ -- \,' V 1 \ , : 1 s 1 \ \ ,. k 1 1 , ,, k 1 k k, ' k k ” k 1 \ \ \ ' 1 l— 1A\ \ \ i,;\ I, \ , \ \ 1,,.\ \ \ \ t,:' \ ,. \ A \ I , 1 k k 1 k 1, k . k 0...... 1A. v k ‘\ \ \ ,, k l ' ‘ k 1 k A \ 1 k i y , \ K‘ ' 1 1 \ \ \ \ 1 \ \i , w 1 ! I 1,,‘ \ n I k 1 t \ \\ I ‘ \ t k k " i \ t A \ l.....• , 1 1, t \ t S t 2„. t 111 1.,.. rc \\\\\k 1....) 1 1 , 111 1 { ' f 4,... 1. Co - II 1 1 1 1 , 1 1C1f'# ; ' 1 11'" Ey I. 11, I It f 1: i 1 too l 111 X1It111I 111131; ' 11= 11 1 1 I HIP J 1v 14 1 ri 1 ` I j 1 1 1 l' 11;,' Gi 1 1 Ei i i i k L 9 6. 12 6 1 1 1 1 k , 1 t , i rJ. 1 t ' j GC JO` h---,-. r, / f 1 tW f 1 r ` - " N' G6, - 2 OUR YP) 5 c \ 1 ": 4' 6 t J r 4 i Y fi l'''''': ` l fi , 1 \ 1 jy • ' , , 9 . , , . cS\, G, 4 l. 4N 1 fiGINZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 March 12, 2010 AC Shelton ACS Construction 711 Hospital St, Suite 12 Richmond, VA 23219 RE: SDP - 2009 -100 Pleasant Grove Baptist Church- Final Dear Sir: Your final site plan as revised 2 /22/10 has been reviewed by Current Development- Planning; see comments below. Additional comments from reviewing departments and agencies may be forthcoming. Please review the comments and revise the plan accordingly. Your revisions should be resubmitted directly to me along with the attached revised application submittal form. Once all comments from all commenting departments /agencies are addressed and the plan meets the requirements of the Albemarle County Code, tentative approval will be granted. After tentative approval is granted you will be required to submit one complete set of plans for final tentative approval. Once tentative final approval is granted you will be notified to submit the final site plan for signature. Do not submit plans for signature until you verify with the planner that you may submit the mylars for signing. When we request plans for signature, we will require two signed and sealed mylar copies of the site plan (the original and a copy for County records) and two paper copies. Once submitted the plan should be signed within one week. Current Development Comments: 1. While telephone easement reference is on the plans, it is not clear how the 20' easement is applied. Please clarify limits of the easement, i.e. is it 20' centered on the telephone lines ?? The arrow drawn (sheet 6) does not make it clear how the easement is applied. Please contact me at 296- 5832 x3432 if you have questions or require additional information. Sincerely, Elizabeth M. Maro a, Senior Planner il rP W I Zoning & Current Development File: SDP - 2009 -75 Cc: Pleasant Grove Baptist Church 1 I1 s r ,ti COMMONWEALTH OF VIRGINIA VIRGINIA DEPARTMENT OF HEALTH Albemarle County Health Department PO Box 7546 Charlottesville, VA 22906 434) 972-6219 AOSE Construction Permit Approval Letter — Level 1 Review April 26, 2010 Pleasant Grove Baptist Church C/0 AC Shelton 711 Hospital Street #Suite 12 Richmond, VA 23219 Subject: Sewage Disposal System Construction Permit Health Departmenet I.D. # 101 -10 -0106 TMP # 31 -27A1 Dear Mr. Shelton: This letter, in conjunction with the approved plans (17 pages) dated December 8th 2009, which are attached, constitutes your permit to install a sewage disposal system [and well]. The application for a permit was submitted pursuant to §32.1 -163.5 of the Code of Virginia which requires the Health Department to accept private soil evaluations and designs from an Authorized Onsite Soil Evaluator (AOSE) or a Professional Engineer working in consultation with an AOSE for residential development. The permitted site was certified as being in compliance with the Board of Health's regulations (and local ordinances if the locality has authorized the local health department to accept private evaluations for compliance with local ordinances) by: (Daniel Vaughan Mairs, AOSE # 182, ). This letter is issued in reliance upon that certification. The Board of Health hereby recognizes that the soil and site conditions acknowledged by this correspondence, and documented by additional records on file at the local health department, are suitable for the installation of onsite sewage disposal systems. The attached plat (or plats) shows the approved areas for the sewage disposal systems. This letter is void if there is any substantial physical change in the soil or site conditions where a sewage disposal system is to be located. If modifications or revisions are necessary between now and when you construct your dwelling, please contact the Authorized Onsite Soil Evaluator (AOSE) or Professional Engineer (PE) who performed the evaluation and design on which this permit is based. The name, address, and phone number of the AOSE /PE appears on the certification form attached to this permit. Should revisions be necessary during construction, your contractor should consult with the AOSE/PE that submitted the site evaluation or site evaluation and design. The AOSE or PE is authorized to make minor adjustments in the location or design of the system at the time of construction provided adequate documentation is provided to the Albemarle County Health Department. This authorization is null and void if conditions are changed from those shown on the application or conditions are changed from those shown on the attached construction drawings, plans and specifications. No part of any installation shall be covered or used until inspected, corrections made if necessary, and approved by the Albemarle County Health Department or unless expressly authorized by the Albemarle County Health Department. Any part of any installation which has been covered prior to approval shall be uncovered if necessary, upon the direction of the Department. This authorization to construct a sewage disposal system expires: October 26, 2011. Sincerely, 7 Josh Kirtley Env. Health Specialist cc: Daniel Vaughan Maus - AOSE # 182 1670 Merriefields Lane Ruckersvilie, Virginia 22968 20i'i n. OE 3 3 7y,1 r 4r 01 DA9AT CONDO PAGE Di Site Distance and Temp: ary Grading i° a',: °ranant Agreement between Adventure Farm LLC and Pleasant Grove Baptist Church March 23, 2010 Page 1 of 2 Adventure Farm LLC hereby agrees to grant Pleasant Grove Baptist Church (PGBC) a permanent Site Distance Easement and a TTemporaty Grading Easement across a portion of they frontage of its land identified as Alberrmtle County Tax Map Parcel 31 -23J, as set forth below, subject to Special Conditions and Clarifications contained herein. Site Distance and Temporary 'rading Easement: the site distance easement shall only cover the rninin a,ea required by VDOT. The site distance easement, clearing and grad g work shall be limited to a maximum depth of 35 feet along the frontage of said property. Special Conditions and Clarifications: 1. PGBC shah obtain all permits, relocate any utilities as needed, place all bonds and be responsible for all safety precautions necessary for performing all associated work. 2, PGBC shall pay all costs for drafting, platting, reviewing and recording the site distance easement. 3. All vegetation shall be cleared and grubbed for a distance of 5 feet behind a 3:1 cut slope from the ditch line across the entire frontage of the parcel where a cut slope exists. 4. A 3:1 cut slope with an additional 5' of rounding shall be established across the entire frontage of the parcel where a cut slope exists. 5. All soil removed within the graded area shall be delivered to Adventure Farm and stockpiled at a location to be specified adjacent to the former "Sunnyboy Gardens" complex. 6. All disturbed areas shall be re- topsailed with a minimum of 4" of topsoil and seeded with Bonnie Dunes" seed mix (available from Landscape Supply) as follows: Minimum 150 # per acre of seed mix, 350# per acre of 14 -2814 or equivalent fertilizer and 400# per acre of Solu- Cal. 7. Any property monuments disturbed by said construction shall be reset by a licensed land surveyor. 8. A fully established grass surface shall be established on all disturbed areas on the parcel as well as the non -paved area within the VDOT Right of Way across same. 9. PGBC hereby holds Adventure Farm LLC harmless of any claims whatsoever related to work performed as part this Agreement. 04/05/2010 10:06 2393317947 DIPLOMAT CONDO PAGE 02 Site Distance and Temporary Grading Easement Agreement between Adventure Farm LLC and Pleasant Grove Baptist Church March 23, 2010 Page 2 of 2 11 PGBC. tet its contractor shall provide Adventure Farm LLC with a Certificate of Insurance WI — showing a minimum of $$,,1300,000.00 liability coverage, naming Adventure Farm LLC as an Additional Insured, prior to commencing any work on said property and shall maintain said coverage until completion of all work. 11. PGBC hereby acknowledges these easements constitute an infringement on the property of Adventure Farm LLC and as such derive a certain monetary value. PGBC shall cooperate in establishing and acknowledging the value of these donations for tax deduction purposes. 12. Contact and Representative for Adventure Farm LLC for matters related to this Agreement shall be Michael T. Boggs, President & CEO of Haley, Chisholm & Morris, Inc. P 0 Box 550, Earlysville, VA 22936 -0550, 434.978.1000, mboggs( HCMgc.com 13. This Agreement shall be signed by the party or parties authorized to obligate PGBC to all responsibilities contained herein. Provide proof of authorization, 14. This Agreement may be executed in counterparts, each of which shall be an original and all of which together shall constitute a fully - executed Agreement. We hereby agree to all of the above: Grantor: Adventure Farm LLC 2 (Dat-D Mary Ja sholm, Member Manager PO Box v Earlysville, VA 22936 - 0550 434.978.1 000 Grantee: Pleasant Grove Baptist Church Date: Authorized Signature(s) Contact Info: orry,,*._ 4_1 jr Elizabeth Marotta From:Elizabeth Marotta Sent:Tuesday, April 27, 2010 3:26 PM To:AC' Subject:Pleasant Grove update AC, I just wanted to let you know that I did receive health department approval today for Pleasant Grove. With that, Planning has no further comments, but you must still obtain Engineering approval. Thank you, Elizabeth M. Marotta Senior Planner County of Albemarle Community Development Department 401 McIntire Road Charlottesville, VA 22902 434) 296 -5832 Ext. 3432 1 Application #:SDP200900`, J Short Review Co ments Project Name:IPLEASANT GROVE BAPTIST CHURCH - FINAL Date Completed:01/08/2010 Reviewer:Elizabeth Marotta CommDev- Current Development Review Status:Requested Changes Reviews Comments: Note: this final site plan was submitted without an application or fees, and thus was originially thought to be a resubmittal of the preliminary and was late getting routed out and entered into the system seeing as the preliminary was closed out already.) I assigned it a received date of 12/16/09 and went ahead and got a final SDP# assigned to it. As of 1/8/09 the applicant has still not submitted his application or fees. See emails in file, dated 12/16/09, for more. Date Completed:03/12/2010 Reviewer:Elizabeth Marotta CommDev- Current Development Review Status:Requested Changes Reviews Comments: Final approval pending HD confirmation of drainfield locations. Date Completed:04/07/2010 Reviewer:Elizabeth Marotta CommDev- Current Development Review Status:Requested Changes Reviews Comments: Final site plan cannot be approved until HD approval is granted Date Completed:04/27/2010 Reviewer:Elizabeth Marotta CommDev- Current Development Review Status:No Objection Reviews Comments: With HD approval granted, Planning has no additional comments. Final approval cannot be granted Iuntil Engineering and VDOT approval is granted. Tentative sets will not be requested until Engineering and VDOT approval is granted. Date Completed: Reviewer:Elizabeth Marotta CommDev- Current Development Review Status:Pending Reviews Comments: 'one set given to engineering for their approval. Date Completed:01/28/2010 Reviewer:Glenn Brooks Engineer Z &CD Review Status:Administrative Approval Reviews Comments: The possibility of contamination from the Avionics site is a real concern, however the WPO has no authority to do anything about it, other than make this information known. Date Completed:01/13/2010 Reviewer:Gary Whelan ACSA Review Status:No Objection Reviews Comments: Not in jurisdictional area per SDP09 - 75 1 Date Completed:12/18/2009 Reviewer:James Barber Fire Rescue Review Status:No Objection Reviews Comments: Must comply with the Virginia Statewide Fire Prevention Code. Final approval is subject to field inspection and verification. Date Completed:02/24/2010 Reviewer:Joel DeNunzio VDOT Review Status:Approved Page: 1.00 County of Albemarle Printed On: Tuesday, June 01, 2010 Reviews Comments: Please let the icant know that prior to construction, they n' obtain a Land Use Permit for the VDOT Char office. Date Completed: Reviewer:Joel DeNunzio VDOT Review Status:Pending Reviews Comments: Following the moving of the entrance, VDOT review is needed again, particularly in reference to sight distance easements and grading on adjacent property. review is on -going with engineering, and submittals are being done via pdf /email- although no official submittal has been made for action. Date Completed:03/29/2010 Reviewer:John Paul Diez Engineer Z &CD Review Status:Requested Changes Reviews Comments: Official Submittal has not been received Date Completed:04/27/2010 Reviewer:Josh Kirtley Thomas Jefferson Health District Review Status:Approved Reviews Comments: see docs /pics for actual paperwork Date Completed:12/17/2009 Reviewer:Jay Schlothauer Inspections Review Status:No Objection Reviews Comments: Based on plans revised November 24, 2009. No further comments or conditions. Date Completed:01/27/2010 Reviewer:Ron Higgins Building Code Zoning Review Status'No Objection Reviews Comments: Zoning confirmation of SP concept plan conformance required. verbal confirmation given. Date Completed:02/18/2010 Reviewer:Sherri Proctor Admin Zoning Review Review Status:Administrative Approval Reviews Comments: (applicant satisfied this comment, parking requirement is adequate. jreviewing method of calculating required parking, per email /memo from John Shepherd on SP2006 -24 Page. 2.00 County of Albemarle Printed On: Tuesday, June 01, 2010