Loading...
HomeMy WebLinkAboutSDP200500011 Plan - Other (not approved) 2005-02-15 (2)`I MISCELLANEOUS NOTES 1. THIS PLAN IS TO BE USED FOR PRELIMINARY SITE DEVELOPMENT PURPOSES ONLY. 2. SOURCE OF TITLE: THE PROPERTY AS SHOWN ON THIS PLAN IS THE PROPERTY CONVEYED UNTO POST OFFICE LAND TRUST, BY THAT CERTAIN DEED DULY ON RECORD IN THE CLERK'S OFFICE OF THE CIRCUIT COURT OF THE COUNTY OF ALBEMARLE, VIRGINIA IN D.B. 1661 PG. 116. THIS PROPERTY IS INDICATED AS TAX MAP 32 PARCEL 41D. 3. BASED ON GRAPHIC DETERMINATION, THIS PROPERTY LIES IN ZONE "C" ON FEMA FIRM MAP 510006 0125 B, DATED 12/16/80. 4. THE TOTAL AREA OF THE PARCEL OF LAND AS SHOWN IS 3.39 ACRES. THE BOUNDARY AS SHOWN HAS BEEN DETERMINED BY RIVANNA ENGINEERING AND SURVEYING, PLC ON JULY 13, 2004. 5. THE EXISTING TOPOGRAPHY IS BY RIVANNA ENGINEERING AND SURVEYING, PLC AND SUPPLEMENTED BY FAULCONER CONSTRUCTION Co. INC. 6. THE EXISTING ZONING FOR THIS AREA IS PD -MC; EC. 7. THIS PROPERTY IS SERVED BY PUBLIC WATER AND SEWER THROUGH ALBEMARLE COUNTY SERVICE AUTHORITY. 8. THE CONTRACTOR SHALL VERIFY ALL UTILITY INFORMATION PRIOR TO CONSTRUCTION TO INCLUDE TYPE AND SIZE OF PIPE AND SERVICES TO HIS OWN SATISFACTION. ABBREVIATIONS BC BACK OF CURB BM BENCH MARK C/C CENTER TO CENTER C G CURB AND GUTTER CIP CAST IRON PIPE 9 CENTER LINE CMP CORRUGATED METAL PIPE CO CLEAN OUT CONC CONCRETE CY CUBIC YARDS DIA DIAMETER EL ELEVATION ELEC ELECTRIC EX OR EXIST EXISTING FH FIRE HYDRANT GFS GROSS SQUARE FEET HB HORIZONTAL BEND HC HANDICAP INV INVERT IPS IRON PIN SET IPF IRON PIN FOUND LF LINEAR FEET LT LEFT MH MANHOLE SMH SEWER MANHOLE NOTES: NTS NOT TO SCALE O.C. ON CENTER PE POLYETHYLENE PROP PROPOSED RCP REINFORCED CONCRETE PIPE REQ'D REQUIRED RT RIGHT R/W RIGHT OF WAY SS SANITARY SEWER ST STORM STA STATION STD STANDARD S/W SIDEWALK TBA TO BE ABANDONED TBR TO BE REMOVED TC TOP OF CURB TYP TYPICAL UG UNDERGROUND UON UNLESS OTHERWISE NOTED WL WATERLINE W/M WATER METER WW WOVEN WIRE YDS YARDS 6"V 6" VALVE SWM STORMWATER MANAGEMENT SO STORM DRAIN 1. THE SIZE OF THE SYMBOLS MAY VARY FROM THOSE SHOWN. 2. ALL ABBREVIATIONS AND SYMBOLS SHOWN MAY NOT BE USED. GENERAL WATER & SEWER CONDITIONS 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER SERVICE AUTHORITY OFFICIALS AT THE START OF THE WORK. 2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLAN AND WHERE SHOWN, ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL ON HIS OWN INITIATIVE LOCATE ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. 3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS AS ADOPTED BY THE ALBEMARLE COUNTY SERVICE AUTHORITY ON JANUARY 15, 1998. 4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 5. THE CONTRATOR SHALL BE RESPONSIBLE FOR NOTIFYING "MISS UTILLITY" (1-800-552-7001). 6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF 3 FEET OF COVER MEASURED FROM THE TOP OF THE PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 9. BACKFLOW PREVENTION REQUIRED. GENERAL UTILITY NOTES 1. CONTACT MISS UTILITY AT 1-800-552-7001 48 HOURS PRIOR TO ANY GRADING OR DIGGING TO HAVE UNDERGROUND UTILITIES MARKED. THE CONTRACTOR SHALL VERIFY ALL UTILITY INFORMATION PRIOR TO CONSTRUCTION TO INCLUDE TYPE AND SIZE OF PIPE AND SERVICES TO HIS OWN SATISFACTION. 2. ALL EXISTING UTILITIES SHOWN ON THIS PLAN HAVE BEEN TAKEN FROM AVAILABLE RECORDS. THE CONTRACTOR IS REQUIRED TO DIG TEST PITS IN ADVANCE OF TRENCHING IN ORDER TO DETERMINE THE EXACT LOCATION AND ELEVATION AT CROSSINGS. IF A CONFLICT IS, DISCOVERED, NOTIFY WW ASSOCIATES AT (434) 984-2700. PRIOR TO BEGINNING INSTALLATION OF UTILITIES, CONTRACTOR SHALL VERIFY INVERTS AT ALL CONNECTIONS WITH EXISTING UTILITIES PRIOR TO PURCHASING OR ORDERING ANY PRECAST STRUCTURES. 3. ALL HYDRANT LOCATIONS TO BE APPROVED BY THE ALBEMARLE COUNTY FIRE MARSHAL PRIOR TO FINAL APPROVAL BY THE COUNTY AND ARE TO BE INSTALLED ACCORDING TO COUNTY STANDARDS. 4. ALL BLASTING REQUIREMENTS TO INSTALL UTILITIES SHALL REQUIRE A PERMIT AND SHALL BE PERFORMED IN ACCORDANCE WITH THE ALBEMARLE COUNTY STANDARDS AND THE PROJECT SPECIFICATIONS. ADDRESS COUNTY COMMENTS I DMJ 1 05 NO. I REVISION I BY I DATE I N0, 5. ALL STORM SEWER SHALL BE CONSTRUCTED IN ACCORDANCE WITH VDOT SPECIFICATIONS SECTION 302 AND SECTION 240 AND AS SPECIFIED ON THE DRAWINGS. 6. THE CONTRACTOR IS REQUIRED TO PERFORM ALL TESTS REQUIRED BY THE COUNTY OR ALBEMARLE COUNTY SERVICE AUTHORITY TO SECURE ACCEPTANCE OF ALL UTILITIES. 7. ALL CONCRETE USED IN UTILITY CONSTRUCTION SHALL BE 4000 PSI CONCRETE IN ACCORDANCE WITH VOOT SPECIFICATION SECTION 219. 8. NO PLANTINGS OR ERECTION OF OTHER OBSTRUCTIONS SHALL BE MADE WITHIN FOUR FEET OF ANY FIRE HYDRANT. 9. ALL HYDRANT BRANCHES SHALL HAVE A MINIMUM COVER OF 3.0'. 10. ALL UTILITIES TO BE PLACED UNDER EXISTING COUNTY STREETS MUST BE BORED OR JACKED UNLESS SPECIFICALLY APPROVED OTHERWISE OR NOTED ON THE PLANS. 11. WATER METERS SHALL BE LOCATED IN AN ACCESSIBLE LOCATION AND SHALL NOT BE INSTALLED UNDER EXISTING PIPING OR CLOSE TO OTHER FACILITIES. 12, FOR UTILITIES INSTALLED UNDER ROADWAYS AND/OR EASEMENTS PLANNED FOR FUTURE ROADWAYS, BACKFILL SHALL BE COMPACTED TO NOT LESS THAN 95% OF MAXIMUM DENSITY; IN ACCORDANCE WITH VDOT SPECIFICATIONS, SECTIONS 523.03, 302, 303.10, AND 200.02 PER P.F.M. 13. WATER AND SEWER UTILITY CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH ALBEMARLE COUNTY SERVICE AUTHORITY WATER AND SEWER CONSTRUCTION SPECIFICATIONS. 14. A 10 FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED UNLESS OTHERWISE SPECIFIED BETWEEN ALL WATER LINES AND SANITARY SEWER LINES IN ACCORDANCE WITH STATE HEALTH DEPT. STANDARDS. GENERAL NOTES 1. AREAS ON WHICH FILL IS TO BE PLACED SHALL BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL. SOIL MATERIALS SHALL BE FREE OF DEBRIS, ROOTS, WOOD, SCRAP MATERIAL, VEGETATION, REFUSE, SOFT UNSOUND PARTICLES, AND FROZEN DELETERIOUS OR OBJECTION& MATERIALS. THE MAXIMUM PARTICLE DIAMETER SHALL BE ONE-HALF THE LIFT THICKNESS. COMMON FILL MATERIAL SHALL BE UNCLASSIFIED SOIL MATERIAL WITH THE CHARACTERISTICS REQUIRED TO COMPACT TO THE SOIL DENSITY SPECIFIED FOR THE INTEDED LOCATION. BACKFILL AND FILL MATERIAL: ASTM D 2487, CLASSIFICATION GW, GP, GM, GC, SW, SP, SM, SC WITH A MAXIMUM ASTM D4318 LIQUID LIMIT OF 35, MAXIMUM ASTM D 4318 PLASTICITY INDEX OF 12, AND MAXIMUM OF 25 PERCENT BY WEIGHT PASSING ASTM D 1140, NO. 200 SIEVE. SELECT MATERIAL: ASTM D 2487, CLASSIFICATION GW, GP, SW, SP WITH A MAXIMUM OF 10 PERCENT BY WEIGHT PASSING ASTM D 1140, NO. 200 SIEVE. 2. USE SELECT MATERIAL UNDER BUILDINGS AND STRUCTURES; USE FILL AND BACKFILL MATERIAL UNDER PARKING AREAS, ROADS, SIDEWALKS, AND OTHER CONCRETE AND PAVED SURFACES; USE COMMON FILL MATERIAL FOR GENERAL SITE GRADING. PLACE MATERIAL IN MAXIMUM 6" LIFTS. 3. COMPACT LAYERS OF FILL TO 95 PERCENT BY ASTM D 698 BENEATH PAVEMENTS AND WALKS, INCLUDING AREAS THAT MAY BE USED FOR FUTURE CONSTRUCTION. IN OTHER UNPAVED AREAS, COMPACT TO 90 PERCENT BY ASTM D 698. IF THE DENSITY OF THE ADJACENT SOIL IS MORE THAN THE DENSITY SPECIFIED, THEN COMPACT TO A DENSITY NOT LESS THAN THE DENSITY OF THE ADJACENT SOIL. 4. THE STRUCTURE TOPS ARE TO BE SET AFTER FINE GRADING IS FINISHED TO AVOID UNNECESSARY ADJUSTING. 5. ALL FINISHED GRADING, SEEDING AND SODDING SHALL BE DONE IN SUCH A MANNER TO PRECLUDE THE PONDING OF THE WATER ON THE SITE, PARTICULARLY ADJACENT TO THE BUILDINGS OR STORM INLETS. 6. ALL STREETS OUTSIDE PUBLIC RIGHTS-OF-WAY ARE TO BE PRIVATELY OWNED AND MAINTAINED. 7. CONTRACTOR IS TO VERIFY THAT ALL UTILITIES I.E., WATER, SEWER GAS, ELECTRIC, TELEPHONE, CABLE, ETC., ARE IN PLACE PRIOR TO CONSTRUCTION OF SUBBASE AND/OR PAVING. 8. PROPOSED UNDERGROUND UTILITIES SUCH AS ELECTRIC, TELEPHONE, CABLE AND GAS WHICH SERVE THIS FACILITY SHALL BE LOCATED WITH A MINIMUM 5 FOOT SEPARATION FROM PUBLIC WATER MAINS AND SANITARY SEWER. 9. CUT AND PATCH WORK IN EXISTING PUBLIC STREETS MUST BE PERFORMED IN ACCORDANCE WITH VDOT AND ALBEMARLE COUNTY STANDARDS AND SPECIFICATIONS. 10. ALL PIPES SHOWN AS RCP ON PLANS SHALL BE REINFORCED CONCRETE PIPE CONFORMING TO ASTM C-76, UNLESS INDICATED OTHERWISE ON PLANS. 11. ALL CONSTRUCTION SHALL COMPLY WITH OSHA SAFETY STANDARD FOR EXCAVATION 1926 PART P AND OTHER APPLICABLE OSHA REQUIREMENTS. 12. TO THE BEST OF OUR BELIEF AND KNOWLEDGE, THERE ARE NO KNOWN GRAVE SITES ON THE SUBJECT PROPERTY. 13. THESE PLANS AND PROFILES AND ALL THE NEW CONSTRUCTION WITH THIS PLAN SHALL BE IN ACCORDANCE WITH THE CURRENT APPROVED ALBEMARLE COUNTY SERVICE AUTHORITY'S GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, ANY AMENDMENTS THEREOF AND THE STANDARDS AND SPECIFICATIONS OF VDOT. 14. PLANTINGS WILL BE PROVIDED WITH MINOR ADJUSTMENTS IN THE FIELD TO ELIMINATE CONFLICTS WITH OTHER STRUCTURAL FEATURES. COORDINATION NOTES 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2. ANY TIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. 3. THE CONTRACTOR IS TO CHECK THAT ALL EASEMENTS, LETTERS OF PERMISSION, ETC. ARE RECORDED/OBTAINED PRIOR TO THE START OF ANY CONSTRUCTION. REVISION BY I DATE Op? V V n M. JENSEN No. 11484/vo<w �3 G,,4 rj4NAL �'� 4. THE CONTRACTOR IS TO VERIFY THAT THE RELOCATION OF ALL EXISTING UTILITIES IN CONFLICT WITH PROPOSED WORK HAS BEEN COMPLETED, INCLUDING UTILITY POLES. ROADWAY CONSTRUCTION NOTES 1. ALL EXISTING UTILITIES WILL BE ADJUSTED TO GRADE BY THE CONTRACTOR. 2. STABLE SUBGRADE IS DEFINED AS THAT SOLID, UNDISTURBED EARTH CAPABLE OF SUPPORTING STREET LOADING WITHOUT DAMAGING SETTLEMENT AS DETERMINED BY THE ENGINEER. 3. WHERE UNSTABLE SUBGRADE IS ENCOUNTERED, IT SHALL BE MADE STABLE BY COMPACTION OR REPLACEMENT AS REQUIRED. 4. ALL CONCRETE SHALL BE CLASS "A3" UNLESS SPECIFIED OTHERWISE. 5. ALL BITUMINOUS SURFACE TO BE TYPE SM -9.5A (VDOT) UNLESS SPECIFIED OTHERWISE. 6. ALL BITUMINOUS BINDER OR BASE COURSES TO BE TYPE BM -25.0 (VDOT) UNLESS OTHERWISE SPECIFIED BY THE ENGINEER AND SHOWN ON APPROVED PLANS. 7. ALL DETAILS OF PAVING ARE SUBJECT TO FINAL APPROVAL BY THE ALBEMARLE COUNTY ENG. DEPT. AND SHALL BE NOTED ON THE FINAL PLANS AND PERMITS. 8. CONTRACTOR TO GRIND OR MILL EXISTING PAVEMENT AS REQUIRED TO OVERLAY EXISTING PAVEMENT AND TO INDUCE REQUIRED CROSS -SLOPE. PROVIDE HEEL CUT AND SMOOTH FINISH SURFACE BETWEEN LIMIT OF OVERLAY AND EXISTING PAVEMENT SURFACE. 9. A SMOOTH GRADE SHALL BE MAINTAINED FROM THE CENTERLINE OF THE EXISTING ROAD TO THE PROPOSED EDGE OF PAVEMENT TO PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR THE PONDING OF ANY WATER IN THE ROADWAY. 10. PAINT FOR PAVEMENT MARKINGS SHALL BE TRAFFIC LANE MARKING PAINT, FACTORY MIXED, QUICK -DRYING, AND NON-BLEEDING. PAINT SHALL MEET REQUIREMENTS OF VDOT, ROAD BRIDGE SPECIFICATIONS, SECTION 231. 11. HANDICAP RAMPS SHALL HAVE EXPOSED AGGREGATE DETECTABLE WARNING FINISH, IN ACCORDANCE WITH VDOT STANDARD CG -12A. RAMPS SHALL NOT EXCEED A MAXIMUM SLOPE OF 12:1. 12. ALL UTILITIES, INCLUDING ALL POLES, NECESSARY TO BE RELOCATED SHALL BE AT THE DEVELOPER'S EXPENSE, PRIOR TO CONSTRUCTION. 13. ALL R/W DEDICATED TO PUBLIC USE SHALL BE CLEAR AND UNENCUMBERED. THE COUNTY/CITY SHALL OBTAIN A PERMIT FOR ALL SIDEWALKS WITHIN THE R/W THAT ARE NOT PRIVATELY MAINTAINED. 14. SIGNS & PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH VDOT STANDARDS. SITE PLAN NOTES 1. ALL CONSTRUCTION SHALL CONFORM TO ALBEMARLE COUNTY AND VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS. 2. CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY OWNER AND ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND APPROVED PLAN. 3. EXISTING MANHOLE FRAMES AND COVERS AND VALVE BOXES AND COVERS TO REMAIN SHALL BE ADJUSTED OR RECONSTRUCTED, AS NECESSARY, TO MATCH FINISHED GRADES. 4. ALL INTERNAL STREETS AND PARKING AREAS ARE TO BE PRIVATELY OWNED AND MAINTAINED. 5. ALL INTERNAL WALKWAYS, UNLESS OTHERWISE NOTED, ARE TO BE PRIVATELY OWNED AND MAINTAINED. 6. EARTH SWALES AND STORM SEWER CONNECTIONS SHALL BE CONSTRUCTED IMMEDIATLEY FOLLOWING CLEARING AND GRUBBING. 7. ALL ON SITE IMPROVEMENTS ARE SUBJECT TO INSPECTION UNDER ALBEMARLE COUNTY CODES. 8. ALL STAIRS WITH THREE OR MORE RISERS ARE TO HAVE HANDRAILS ON BOTH SIDES. 9. SIDEWALKS ADJACENT TO TRAVELWAYS ARE 6 FEET WIDE UNLESS OTHERWISE NOTED 10. CONTRACTOR TO VERIFY ALL SITE PLANS AND PROFILES AND DETAILS FOR CONSISTENCY AND IF CONFLICT EXISTS, CONTACT ENGINEER FOR CLARIFICATION AND/OR DIRECTION. INTERPRETATION DETERMINED BY CONTRACTOR SHALL BE DONE AT HIS/HER OWN RISK. ALBEMARLE COUNTY ENGINEERING - GENERAL CONSTRUCTION NOTES FOR SITE PLANS 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL PAVING, DRAINAGE RELATED MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. ENGINEERS SURVEYORS PLANNM 147 Mill RWp Rad 1402 Grembdar Phm LyerbbW1_24502 Mwi.me. ft VA 22901 PPL�oa®ea 443344.5V 6175 Phone: 434,984.2700 www.wwasocisugmat 5. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE ALBEMARLE COUNTY DIRECTOR OF ENGINEERING, OR THE DIRECTOR'S DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE "VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES". 7. UNLESS OTHERWISE NOTED, ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 8. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). LEGEND EXISTING NEW DESCRIPTION ---435--- -435- CONTOUR INTERVAL AS INDICATED ON SITE PLAN) 56.1 •56.1 SPOT ELEVATION r'y Y1 TREE LINE X X DEMOLISH EXISTING UGT CENTER/EDGE OF STREAM FENCE AND GATE FIRE EDGE OF PAVEMENT - - - - PROPERTY LINE/RIGHT OF WAY ---- CG -2 HEADER CURB WATER VALVE CURB AND GUTTER --� OVERHEAD POWER O AND/OR TELEPHONE SS E:fol C -q SANITARY SEWER 0o STORM DRAIN AND END WALL, SANITARY CLEAN OUT TYPE AS INDICATED - 8" W WATER LINE -Tw :FW - TRAFFIC WIRE - HGE UGE - UNDERGROUND ELECTRICAL - -- - - UNDERGROUND TELEPHONE A, A -A, ABANDONED OR REMOVED UTILITY STRUCTURE • O IRON PIN ..A �. CONCRETE SIDEWALK QNUMBER OF PARKING SPACES NOTES: 1 • MAY VARY FROM TSHOSEO SHOWN. 2. ALL ABBREVIATIONS AND SYMBOLS SHOWN MAY NOT BE USED. DESIGNED BY PROJECT. HOLLYMEAD TOWN CENTER DMJ DRAWN BY: AREA C, BLOCK 9 JPD PRELIMINARY SITE PLAN TITLE: REVIEWED BY: DMJ WWA NUMBER: FILE NAME: 204225.00co block 9 working.dwg GENERAL NOTES DISCIPLINE: SCALE: DATE: CIVIL NONE 02/15/05 REVISION NUMBER: DRAWING NUMBER: C-2 SHEET NUMBER: 2 OF 7 C WATER METER FHS FIRE HYDRANT FIRE IFDC DEPARTMENT CONNECTION WATER VALVE O SANITARY MANHOLE O O STORM MANHOLE E:fol C -q CURB DROP INLET oco ---eco SANITARY CLEAN OUT LIGHT POLE --j 0_- TELEPHONE POLE, WITH GUY AND ANCHOR -� -a- POWER POLE -0- SIGN • O IRON PIN ..A �. CONCRETE SIDEWALK QNUMBER OF PARKING SPACES NOTES: 1 • MAY VARY FROM TSHOSEO SHOWN. 2. ALL ABBREVIATIONS AND SYMBOLS SHOWN MAY NOT BE USED. DESIGNED BY PROJECT. HOLLYMEAD TOWN CENTER DMJ DRAWN BY: AREA C, BLOCK 9 JPD PRELIMINARY SITE PLAN TITLE: REVIEWED BY: DMJ WWA NUMBER: FILE NAME: 204225.00co block 9 working.dwg GENERAL NOTES DISCIPLINE: SCALE: DATE: CIVIL NONE 02/15/05 REVISION NUMBER: DRAWING NUMBER: C-2 SHEET NUMBER: 2 OF 7