HomeMy WebLinkAboutSDP200500011 Plan - Other (not approved) 2005-02-15 (3)MISCELLANEOUS NOTES
1. THIS PLAN IS TO BE USED FOR PRELIMINARY SITE DEVELOPMENT PURPOSES ONLY.
2. SOURCE OF TITLE:
THE PROPERTY AS SHOWN ON THIS PLAN IS THE PROPERTY CONVEYED UNTO
POST OFFICE LAND TRUST, BY THAT CERTAIN DEED DULY ON RECORD
IN THE CLERK'S OFFICE OF THE CIRCUIT COURT OF THE COUNTY OF ALBEMARLE,
VIRGINIA IN D.B. 1661 PG. 116. THIS PROPERTY IS INDICATED AS TAX MAP 32 PARCEL 41D.
3. BASED ON GRAPHIC DETERMINATION, THIS PROPERTY LIES IN ZONE "C" ON FEMA
FIRM MAP 510006 0125 B, DATED 12/16/80.
4. THE TOTAL AREA OF THE PARCEL OF LAND AS SHOWN IS 37.13 ACRES. THE
BOUNDARY AS SHOWN HAS BEEN DETERMINED FROM RIVANNA ENGINEERING
AND SURVEYING, PLC ON JULY 13, 2004.
5. THE EXISTING TOPOGRAPHY IS FROM BY OTHERS, CHARLOTTESVILLE, VA.
6. THE EXISTING ZONING FOR THIS AREA IS PD -MC; EC.
7. THIS PROPERTY IS SERVED BY PUBLIC WATER AND SEWER THROUGH ALBEMARLE COUNTY
SERVICE AUTHORITY.
8. THE CONTRACTOR SHALL VERIFY ALL UTILITY INFORMATION PRIOR TO
CONSTRUCTION TO INCLUDE TYPE AND SIZE OF PIPE AND SERVICES TO
HIS OWN SATISFACTION.
ABBREVIATIONS
BC
BACK OF CURB
BM
BENCH MARK
C/C
CENTER TO CENTER
C G
CURB AND GUTTER
CIP
CAST IRON PIPE
CL
CENTER LINE
CMP
CORRUGATED METAL PIPE
CO
CLEAN OUT
CONC
CONCRETE
CY
CUBIC YARDS
DIA
DIAMETER
EL
ELEVATION
ELEC
ELECTRIC
EX OR EXIST
EXISTING
FH
FIRE HYDRANT
GFS
GROSS SQUARE FEET
HB
HORIZONTAL BEND
HC
HANDICAP
INV
INVERT
IPS
IRON PIN SET
IPF
IRON PIN FOUND
LF
LINEAR FEET
LT
LEFT
MH
MANHOLE
SMH
SEWER MANHOLE
NOTES:
NTS
NOT TO SCALE
O.C.
ON CENTER
PE
POLYETHYLENE
PROP
PROPOSED
RCP
REINFORCED CONCRETE PIPE
REQ'D
REQUIRED
RT
RIGHT
R/W
RIGHT OF WAY
SS
SANITARY SEWER
ST
STORM
STA
STATION
STD
STANDARD
S/W
SIDEWALK
TBA
TO BE ABANDONED
TBR
TO BE REMOVED
TC
TOP OF CURB
TYP
TYPICAL
UG
UNDERGROUND
UON
UNLESS OTHERWISE NOTED
WL
WATERLINE
WW
WOVEN WIRE
YDS
YARDS
60V
6" VALVE
SWM
STORMWATER MANAGEMENT
SD
STORM DRAIN
1. THE SIZE OF THE SYMBOLS MAY VARY FROM THOSE SHOWN.
2. ALL ABBREVIATIONS AND SYMBOLS SHOWN MAY NOT BE USED.
GENERAL WATER & SEWER CONDITIONS
1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE
AUTHORITY INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING
THE PROPER SERVICE AUTHORITY OFFICIALS AT THE START OF THE WORK.
2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK
ARE NOT NECESSARILY SHOWN ON THE PLAN AND WHERE SHOWN, ARE ONLY
APPROXIMATELY CORRECT. THE CONTRACTOR SHALL ON HIS OWN INITIATIVE
LOCATE ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY.
3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH GENERAL WATER AND
SEWER CONSTRUCTION SPECIFICATIONS AS ADOPTED BY THE ALBEMARLE COUNTY
SERVICE AUTHORITY ON JANUARY 15, 1998.
4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY.
5. THE CONTRATOR SHALL BE RESPONSIBLE FOR NOTIFYING
"MISS UTILLITY" (1-800-552-7001).
6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF 3 FEET OF COVER
MEASURED FROM THE TOP OF THE PIPE, OVER THE CENTERLINE OF PIPE.
THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC.
7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED
OUTSIDE OF ROADSIDE DITCHES.
8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT
FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE.
GENERAL UTILITY NOTES
1. CONTACT MISS UTILITY AT 1-800-552-7001 48 HOURS PRIOR TO ANY
GRADING OR DIGGING TO HAVE UNDERGROUND UTILITIES MARKED.
THE CONTRACTOR SHALL VERIFY ALL UTILITY INFORMATION PRIOR
TO CONSTRUCTION TO INCLUDE TYPE AND SIZE OF PIPE AND SERVICES
TO HIS OWN SATISFACTION.
2. ALL EXISTING UTILITIES SHOWN ON THIS PLAN HAVE BEEN TAKEN
FROM AVAILABLE RECORDS. THE CONTRACTOR IS REQUIRED TO DIG
TEST PITS IN ADVANCE OF TRENCHING IN ORDER TO DETERMINE THE
EXACT LOCATION AND ELEVATION AT CROSSINGS. IF A CONFLICT IS,
DISCOVERED, NOTIFY WW ASSOCIATES AT (434) 984-2700. PRIOR TO
BEGINNING INSTALLATION OF UTILITIES, CONTRACTOR SHALL VERIFY
INVERTS AT ALL CONNECTIONS WITH EXISTING UTILITIES PRIOR TO
PURCHASING OR ORDERING ANY PRECAST STRUCTURES.
3. ALL HYDRANT LOCATIONS TO BE APPROVED BY THE ALBEMARLE COUNTY
FIRE MARSHAL PRIOR TO FINAL APPROVAL BY THE COUNTY AND ARE TO
BE INSTALLED ACCORDING TO COUNTY STANDARDS.
4. ALL BLASTING REQUIREMENTS TO INSTALL UTILITIES SHALL REQUIRE
A PERMIT AND SHALL BE PERFORMED IN ACCORDANCE WITH THE
ALBEMARLE COUNTY STANDARDS AND THE PROJECT SPECIFICATIONS.
5. ALL STORM SEWER SHALL BE CONSTRUCTED IN ACCORDANCE WITH
VDOT SPECIFICATIONS SECTION 302 AND SECTION 240 AND AS SPECIFIED
ON THE DRAWINGS.
6. THE CONTRACTOR IS REQUIRED TO PERFORM ALL TESTS REQUIRED
BY THE COUNTY OR ALBEMARLE COUNTY SERVICE AUTHORITY TO
SECURE ACCEPTANCE OF ALL UTILITIES.
7. ALL CONCRETE USED IN UTILITY CONSTRUCTION SHALL BE 4000 PSI
CONCRETE IN ACCORDANCE WITH VDOT SPECIFICATION SECTION 219.
8. NO PLANTINGS OR ERECTION OF OTHER OBSTRUCTIONS SHALL BE
MADE WITHIN FOUR FEET OF ANY FIRE HYDRANT.
9. ALL HYDRANT BRANCHES SHALL HAVE A MINIMUM COVER OF 3.0'.
10. ALL UTILITIES TO BE PLACED UNDER EXISTING COUNTY STREETS
MUST BE BORED OR JACKED UNLESS SPECIFICALLY APPROVED
OTHERWISE OR NOTED ON THE PLANS.
11. WATER METERS SHALL BE LOCATED IN AN ACCESSIBLE LOCATION
AND SHALL NOT BE INSTALLED UNDER EXISTING PIPING OR CLOSE TO
OTHER FACILITIES.
12. FOR UTILITIES INSTALLED UNDER ROADWAYS AND/OR EASEMENTS
PLANNED FOR FUTURE ROADWAYS, BACKFILL SHALL BE COMPACTED
TO NOT LESS THAN 95% OF MAXIMUM DENSITY; IN ACCORDANCE
WITH VDOT SPECIFICATIONS, SECTIONS 523.03, 302, 303.10,
AND 200.02 PER P.F.M.
13. WATER AND SEWER UTILITY CONSTRUCTION SHALL BE PERFORMED IN
ACCORDANCE WITH ALBEMARLE COUNTY SERVICE AUTHORITY WATER AND
SEWER CONSTRUCTION SPECIFICATIONS.
14. A 10 FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED UNLESS
OTHERWISE SPECIFIED BETWEEN ALL WATER LINES AND SANITARY
SEWER LINES IN ACCORDANCE WITH STATE HEALTH DEPT. STANDARDS.
GENERAL NOTES
1. AREAS ON WHICH FILL IS TO BE PLACED SHALL BE CLEARED, GRUBBED,
AND STRIPPED OF TOPSOIL. SOIL MATERIALS SHALL BE FREE OF DEBRIS,
ROOTS, WOOD, SCRAP MATERIAL, VEGETATION, REFUSE, SOFT UNSOUND
PARTICLES, AND FROZEN DELETERIOUS OR OBJECTION& MATERIALS. THE
MAXIMUM PARTICLE DIAMETER SHALL BE ONE-HALF THE LIFT THICKNESS.
COMMON FILL MATERIAL SHALL BE UNCLASSIFIED SOIL MATERIAL WITH THE
CHARACTERISTICS REQUIRED TO COMPACT TO THE SOIL DENSITY SPECIFIED
FOR THE INTEDED LOCATION. BACKFILL AND FILL MATERIAL: ASTM D 2487,
CLASSIFICATION GW, GP, GM, GC, SW, SP, SM, SC WITH A MAXIMUM ASTM
D4318 LIQUID LIMIT OF 35, MAXIMUM ASTM D 4318 PLASTICITY INDEX OF 12,
AND MAXIMUM OF 25 PERCENT BY WEIGHT PASSING ASTM D 1140, NO. 200
SIEVE. SELECT MATERIAL: ASTM D 2487, CLASSIFICATION GW, GP, SW, SP
WITH A MAXIMUM OF 10 PERCENT BY WEIGHT PASSING ASTM D 1140,
NO. 200 SIEVE.
2. USE SELECT MATERIAL UNDER BUILDINGS AND STRUCTURES; USE FILL AND
BACKFILL MATERIAL UNDER PARKING AREAS, ROADS, SIDEWALKS, AND OTHER
CONCRETE AND PAVED SURFACES; USE COMMON FILL MATERIAL FOR GENERAL
SITE GRADING. PLACE MATERIAL IN MAXIMUM 6" LIFTS.
3. COMPACT LAYERS OF FILL TO 95 PERCENT BY ASTM D 698 BENEATH
PAVEMENTS AND WALKS, INCLUDING AREAS THAT MAY BE USED FOR FUTURE
CONSTRUCTION. IN OTHER UNPAVED AREAS, COMPACT TO 90 PERCENT BY
ASTM D 698. IF THE DENSITY OF THE ADJACENT SOIL IS MORE THAN THE
DENSITY SPECIFIED, THEN COMPACT TO A DENSITY NOT LESS THAN THE
DENSITY OF THE ADJACENT SOIL.
4. THE STRUCTURE TOPS ARE TO BE SET AFTER FINE GRADING IS
FINISHED TO AVOID UNNECESSARY ADJUSTING.
5. ALL FINISHED GRADING, SEEDING AND SODDING SHALL BE DONE IN
SUCH A MANNER TO PRECLUDE THE PONDING OF THE WATER ON THE
SITE, PARTICULARLY ADJACENT TO THE BUILDINGS OR STORM INLETS.
6. ALL STREETS OUTSIDE PUBLIC RIGHTS-OF-WAY ARE TO BE PRIVATELY
OWNED AND MAINTAINED.
7. CONTRACTOR IS TO VERIFY THAT ALL UTILITIES I.E., WATER, SEWER
GAS, ELECTRIC, TELEPHONE, CABLE, ETC., ARE IN PLACE PRIOR TO
CONSTRUCTION OF SUBBASE AND/OR PAVING.
8. PROPOSED UNDERGROUND UTILITIES SUCH AS ELECTRIC,
TELEPHONE, CABLE AND GAS WHICH SERVE THIS FACILITY SHALL BE
LOCATED WITH A MINIMUM 5 FOOT SEPARATION FROM PUBLIC
WATER MAINS AND SANITARY SEWER.
9. CUT AND PATCH WORK IN EXISTING PUBLIC STREETS MUST BE
PERFORMED IN ACCORDANCE WITH VDOT AND ALBEMARLE COUNTY
STANDARDS AND SPECIFICATIONS.
10. ALL PIPES SHOWN AS RCP ON PLANS SHALL BE REINFORCED
CONCRETE PIPE CONFORMING TO ASTM C-76, UNLESS INDICATED
OTHERWISE ON PLANS.
11. ALL CONSTRUCTION SHALL COMPLY WITH OSHA SAFETY STANDARD
FOR EXCAVATION 1926 PART P AND OTHER APPLICABLE OSHA
REQUIREMENTS.
12. TO THE BEST OF OUR BELIEF AND KNOWLEDGE, THERE ARE NO
KNOWN GRAVE SITES ON THE SUBJECT PROPERTY.
13. THESE PLANS AND PROFILES AND ALL THE NEW CONSTRUCTION
WITH THIS PLAN SHALL BE IN ACCORDANCE WITH THE CURRENT
APPROVED ALBEMARLE COUNTY SERVICE AUTHORITY'S GENERAL WATER
AND SEWER CONSTRUCTION SPECIFICATIONS, ANY AMENDMENTS
THEREOF AND THE STANDARDS AND SPECIFICATIONS OF VDOT.
14. PLANTINGS WILL BE PROVIDED WITH MINOR ADJUSTMENTS IN THE FIELD TO
ELIMINATE CONFLICTS WITH OTHER STRUCTURAL FEATURES.
COORDINATION NOTES
1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS
REQUIRED FOR CONSTRUCTION OF THESE PLANS.
2. ANY TIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING
EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID
EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW
ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR
REFERENCED IN THE RECORDED EASEMENT.
3. THE CONTRACTOR IS TO CHECK THAT ALL EASEMENTS, LETTERS OF
PERMISSION, ETC. ARE RECORDED/OBTAINED PRIOR TO THE START
OF ANY CONSTRUCTION.
TH OF
DAVID M. JENSEN
No. 11484
NO. I REVISION I BY I DATE I NO. I REVISION I BY
4. THE CONTRACTOR IS TO VERIFY THAT THE RELOCATION OF ALL
EXISTING UTILITIES IN CONFLICT WITH PROPOSED WORK HAS BEEN
COMPLETED, INCLUDING UTILITY POLES.
ROADWAY CONSTRUCTION NOTES
1. ALL EXISTING UTILITIES WILL BE ADJUSTED TO GRADE BY THE
CONTRACTOR.
2. STABLE SUBGRADE IS DEFINED AS THAT SOLID, UNDISTURBED EARTH
CAPABLE OF SUPPORTING STREET LOADING WITHOUT DAMAGING
SETTLEMENT AS DETERMINED BY THE ENGINEER.
3. WHERE UNSTABLE SUBGRADE IS ENCOUNTERED, IT SHALL BE MADE
STABLE BY COMPACTION OR REPLACEMENT AS REQUIRED.
4. ALL CONCRETE SHALL BE CLASS "A3" UNLESS SPECIFIED OTHERWISE.
5. ALL BITUMINOUS SURFACE TO BE TYPE SM -9.5A (VDOT) UNLESS
SPECIFIED OTHERWISE.
6. ALL BITUMINOUS BINDER OR BASE COURSES TO BE TYPE BM -25.0 (VDOT)
UNLESS OTHERWISE SPECIFIED BY THE ENGINEER AND SHOWN ON
APPROVED PLANS.
7. ALL DETAILS OF PAVING ARE SUBJECT TO FINAL APPROVAL BY THE
ALBEMARLE COUNTY ENG. DEPT. AND SHALL BE NOTED ON
THE FINAL PLANS AND PERMITS.
8. CONTRACTOR TO GRIND OR MILL EXISTING PAVEMENT AS REQUIRED
TO OVERLAY EXISTING PAVEMENT AND TO INDUCE REQUIRED
CROSS -SLOPE. PROVIDE HEEL CUT AND SMOOTH FINISH SURFACE
BETWEEN LIMIT OF OVERLAY AND EXISTING PAVEMENT SURFACE.
9. A SMOOTH GRADE SHALL BE MAINTAINED FROM THE CENTERLINE OF
THE EXISTING ROAD TO THE PROPOSED EDGE OF PAVEMENT TO
PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR THE PONDING
OF ANY WATER IN THE ROADWAY.
10. PAINT FOR PAVEMENT MARKINGS SHALL BE TRAFFIC LANE MARKING PAINT,
FACTORY MIXED, QUICK -DRYING, AND NON-BLEEDING. PAINT SHALL MEET
REQUIREMENTS OF VDOT, ROAD BRIDGE SPECIFICATIONS, SECTION 231.
11. HANDICAP RAMPS SHALL HAVE EXPOSED AGGREGATE DETECTABLE WARNING
FINISH, IN ACCORDANCE WITH VDOT STANDARD CG -12A. RAMPS SHALL
NOT EXCEED A MAXIMUM SLOPE OF 12:1.
12. ALL UTILITIES, INCLUDING ALL POLES, NECESSARY TO BE
RELOCATED SHALL BE AT THE DEVELOPER'S EXPENSE, PRIOR TO
CONSTRUCTION.
13. ALL R/W DEDICATED TO PUBLIC USE SHALL BE CLEAR AND
UNENCUMBERED. THE COUNTY/CITY SHALL OBTAIN A PERMIT FOR
ALL SIDEWALKS WITHIN THE R/W THAT ARE NOT PRIVATELY
MAINTAINED.
14. SIGNS & PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH VDOT
STANDARDS.
SITE PLAN NOTES
1. ALL CONSTRUCTION SHALL CONFORM TO ALBEMARLE COUNTY
AND VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS
AND SPECIFICATIONS.
2. CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO AND DURING
CONSTRUCTION AND NOTIFY OWNER AND ENGINEER IMMEDIATELY OF ANY
DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND APPROVED
PLAN.
3. EXISTING MANHOLE FRAMES AND COVERS AND VALVE BOXES AND
COVERS TO REMAIN SHALL BE ADJUSTED OR RECONSTRUCTED, AS
NECESSARY, TO MATCH FINISHED GRADES.
4. ALL INTERNAL STREETS AND PARKING AREAS ARE TO BE PRIVATELY
OWNED AND MAINTAINED.
5. ALL INTERNAL WALKWAYS, UNLESS OTHERWISE NOTED, ARE TO BE
PRIVATELY OWNED AND MAINTAINED.
6. EARTH SWALES AND STORM SEWER CONNECTIONS SHALL BE
CONSTRUCTED IMMEDIATLEY FOLLOWING CLEARING AND GRUBBING.
7. ALL ON SITE IMPROVEMENTS ARE SUBJECT TO INSPECTION UNDER
ALBEMARLE COUNTY CODES.
8. ALL STAIRS WITH THREE OR MORE RISERS ARE TO HAVE HANDRAILS
ON BOTH SIDES.
9. SIDEWALKS ADJACENT TO TRAVELWAYS ARE 6 FEET WIDE UNLESS
OTHERWISE NOTED
10. CONTRACTOR TO VERIFY ALL SITE PLANS AND PROFILES AND
DETAILS FOR CONSISTENCY AND IF CONFLICT EXISTS, CONTACT
ENGINEER FOR CLARIFICATION AND/OR DIRECTION. INTERPRETATION
DETERMINED BY CONTRACTOR SHALL BE DONE AT HIS/HER OWN
RISK.
ALBEMARLE COUNTY ENGINEERING - GENERAL CONSTRUCTION NOTES FOR SITE PLANS
1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY,
INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED
FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS
DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT.
WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL
GOVERN.
2. ALL PAVING, DRAINAGE RELATED MATERIALS AND CONSTRUCTION METHODS SHALL
CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS
OTHERWISE NOTED.
3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE
WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO
ANY CLEARING, GRADING OR OTHER CONSTRUCTION.
4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED.
THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE
REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED.
ENGINEERS
ME SURVEYORS
PLANNERS
ASSOCIATES
147 Mill ridge R09 1402 amedlew Ph=
Ly>�botp vA U'M Cbnb�7lg VA "%I
ppm 4_34582.6175 Phone: 434984.2700
w"..nat
5. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE
OPINION OF THE ALBEMARLE COUNTY DIRECTOR OF ENGINEERING, OR THE DIRECTOR'S
DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL.
6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE 'VIRGINIA MANUAL FOR UNIFORM
TRAFFIC CONTROL DEVICES".
7. UNLESS OTHERWISE NOTED, ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE
PIPE - CLASS III.
8. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA
STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926).
LEGEND
EXISTING NEW DESCRIPTION
---435--- - 435 - CONTOUR (INTERVAL AS
INDICATED ON SITE PLAN)
-56.1 •56.1 SPOT ELEVATION
��� rYYY1 TREE LINE
UGT CENTER/EDGE OF STREAM
FENCE AND GATE
EDGE OF PAVEMENT
PROPERTY LINE/RIGHT OF WAY
TAX MAP LINE
¢ OVERHEAD POWER
AND/OR TELEPHONE
_ SS
-- _- SANITARY SEWER
SD STORM DRAIN AND END WALL,
TYPE AS INDICATED
8 WL WATER LINE
W-- - W TRAFFIC WIRE
YGE - UGE UNDERGROUND ELECTRICAL
-:F- ---W6T-- UNDERGROUND TELEPHONE
ABANDONED OR REMOVED
UTILITY
STRUCTURE
4_e CURB DROP INLET
pco ---eco SANITARY CLEAN OUT
LIGHT POLE
TELEPHONE POLE, WITH GUY
AND ANCHOR
�- POWER POLE
-Q- SIGN
SEE LANDSCAPE PLAN L-1 TREE
SEE LANDSCAPE PLAN L-1 BUSH
OVOVOVOVC
„ go„o„o,, RIPRAP
IRON PIN
PIN
CONCRETE SIDEWALK
177 NEW SHOULDER
° NEW TURN LANE PAVEMENT
NOTES: 1. THE SIZE OF THE SYMBOLS
MAY VARY FROM THOSE SHOWN.
2. ALL ABBREVIATIONS AND SYMBOLS
SHOWN MAY NOT BE USED.
DESIGNED BY. PROJECT: HOLLYMEAD TOWN CENTER
DMJ
DRAWN BY: AREA C. BLOCK 9
JPD PRELIMINARY SITE PLAN
TITLE.
REVIEWED BY:
DMJ
WWA NUMBER: FILE NAME:
204224.00co block 9 working.dwg
GENERAL NOTES
DISCIPLINE: SCALE: DATE:
CIVIL NONE 02115105
REVISION NUMBER:
0
DRAWING NUMBER:
C-2
SHEET NUMBER:
2 OF 7
4)
WATER METER
FHS
FIRE HYDRANT
IFDC
FIRE
DEPARTMENT CONNECTION
I
WATER VALVE
sm
DAN
O
SANITARY MANHOLE
sT
ST
STORM MANHOLE
m O
DROP INLET
4_e CURB DROP INLET
pco ---eco SANITARY CLEAN OUT
LIGHT POLE
TELEPHONE POLE, WITH GUY
AND ANCHOR
�- POWER POLE
-Q- SIGN
SEE LANDSCAPE PLAN L-1 TREE
SEE LANDSCAPE PLAN L-1 BUSH
OVOVOVOVC
„ go„o„o,, RIPRAP
IRON PIN
PIN
CONCRETE SIDEWALK
177 NEW SHOULDER
° NEW TURN LANE PAVEMENT
NOTES: 1. THE SIZE OF THE SYMBOLS
MAY VARY FROM THOSE SHOWN.
2. ALL ABBREVIATIONS AND SYMBOLS
SHOWN MAY NOT BE USED.
DESIGNED BY. PROJECT: HOLLYMEAD TOWN CENTER
DMJ
DRAWN BY: AREA C. BLOCK 9
JPD PRELIMINARY SITE PLAN
TITLE.
REVIEWED BY:
DMJ
WWA NUMBER: FILE NAME:
204224.00co block 9 working.dwg
GENERAL NOTES
DISCIPLINE: SCALE: DATE:
CIVIL NONE 02115105
REVISION NUMBER:
0
DRAWING NUMBER:
C-2
SHEET NUMBER:
2 OF 7