Loading...
HomeMy WebLinkAboutSDP200500061 Review Comments 2004-09-20II' 7 -p l County of Albemarle Department of Community Development Memorandum To:David Pennock From: Mark Chambers, Engineering Technician Division: Current Development Date:20 Sept. 2004 Subject: Commonwealth- Greenbrier Center Preliminary Site Plan David: Engineering reviewed the subject preliminary plat submitted on June 14, 2005. We do not recommend approval, but request the following changes to bring the preliminary plat in compliance with County Code: 1. The vicinity map was intended for another parcel. Please provide a vicinity map for locating this parcel. 2. Construction of the retaining wall will result in encroachment of tax map 61W, parcel 03 -3A Please provide a letter of intent to grant a temporary grading easement from the owners of tax map 61W, parcel 03 -3A. (DSM, 1102). 3. An arrangement must be made with Albemarle County, General Services Department for work that must take place in Peyton Basin to construct the retaining wall and provide erosion and sediment control for the site. 4. Please show all existing structures and utilities on the parcel i.e. guardrail on Commonwealth Drive, fiber optic cable on north end of parcel, traffic signal support pole and control unit on the corner of Commonwealth and Greenbrier Drives. 5. The entrance must meet VDOT Minimum Standards of Entrances to State Highways. The distance from the edge of pavement (Greenbrier Drive) to the edge of the first parking space, must be a minimum of 25'. 6. Please submit a written request for a critical slope waiver (18- 4.2.5, 18- 32.3.10.4). Please contact me with any questions or concerns about the plan or the above comments. 0v ALg l County of Albemarle Department of Community Development Memorandum To:David Pennock From: Mark Chambers, Engineering Technician Division: Current Development Date:30 June 2005 Subject: Commonwealth- Greenbrier Center, Preliminary Site Plan David: Engineering reviewed the subject preliminary plat submitted on June 14, 2005. We do not recommend approval but request the following changes to bring the preliminary plat in compliance with County Code: 1. The vicinity map was intended for another parcel. Please provide a vicinity map for locating this parcel. 2. Construction of the retaining wall will result in encroachment of tax map 61W, parcel 03 -3A Please provide a letter of intent to grant a temporary grading easement from the owners of tax map 61W, parcel 03 -3A. (DSM, 1102). 3. An arrangement must be made with Albemarle County, General Services Department for work that must take place in Peyton Basin to construct the retaining wall and provide erosion and sediment control for the site. 4. Please show all existing structures and utilities on the parcel i.e. guardrail on Commonwealth Drive, fiber optic cable on north end of parcel, traffic signal support pole and control unit on the comer of Commonwealth and Greenbrier Drives. 5. The entrance must meet VDOT Minimum Standards of Entrances to State Highways. The distance from the edge of pavement (Greenbrier Drive) to the edge of the first parking space, must be a minimum of 25'. 6, Please submit a written request for a critical slope waiver (18- 4.2.5, 18- 32.3.10.4). Please contact me with any questions or concerns about the plan or the above comments. TO: Planner FROM: Gary Whelan, Engineering Technician DATE: June 29, 2005 RE:Site Plan Technical Review for:Commonwealth- Greenbrier Center TM 61 W -3 -6A) The below checked items apply to this site. SDP - 2005 -00061 X 1. This site plan is within the Authority's jurisdictional area for: k . X A. Water and sewer B. Water only C. Water only to existing structure D. Limited service X 2. A 10 inch water line is located approximately 35' distant. X 3. Fire flow from nearest public hydrant, located 75' distant from this site plan, is 2226 gpm + at 20 psi residual. X 4. An 8 inch sewer line is located approximately 15' distant. 5. An Industrial Waste Ordinance survey form must be completed. X 6. No improvements or obstructions shall be placed within existing or future easements. 7.and plans are currently under review. 8.and plans have been received and approved. 9. No plans are required. X 10. Final water and sewer plans are required for our review and approval prior to granting tentative approval. 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. Comments: Show water meter locations. Show sewer laterals. Backflow prevention required. Provide plumbing fixture counts. The site plan does not show or incorrectly shows: X meter locations waterline size waterline locations sewer line size sewer line locations expected wastewater flows easements expected water demands of ALg clops 9pr y t! VIP ! County of Albemarle Department of Community Development Memorandum To:Johnny Drumheller From:David Pennock, Senior Planner Division:Zoning and Current Development Date:July 1, 2005 Subject:SDP 05 -61 - Commonwealth - Greenbrier Center Preliminary Site Plan The Albemarle County Division of Zoning and Community Development: Zoning and Planning Review will approve the final site plan referenced above when the following items have been satisfactorily addressed: [Each comment is preceded by the applicable reference. Unless otherwise noted, citations are within Chapter 18 Zoning) of the Albemarle County Code.] Site Plan Comments 1. Sec. 32.5.3] Proposed grading for this site includes disturbance of slopes 25% or greater. Disturbance of these critical slopes must be approved by the Planning Commission as outlined in Section 4.2.5. 2. Sec. 4.17.4] Will lighting be installed on this site? If so, please provide specification sheets indicating the proposed types of light, wattage, and maximum lumens, as well as the height of each light, and type of installation or shielding. In addition, a photometric layout sheet should be provided. 3. Retaining walls greater than 4 feet in height constitute a potential safety hazard and must be topped with a barrier of some type in accordance with State building code. Please indicate some method of safeguarding these areas. 4. Sec. 32.5.6(e)] As part of the landscape plan, or on a separate sheet, please indicate existing landscape features on the site, as described in Section 32.7.9.4. 5. Sec. 32.5.6(n)] Please indicate proposed location for any signs. All signs will require separate sign permits prior to installation. 6. Sec. 32.5.6(m)] As this plan covers three lots that all share one entrance, please provide evidence of recordation of a cross access easement. 7. Sec. 32.7.2.8] Please provide sidewalk linkages from this site to adjoining properties in accordance with Section 32.7.2.8. If proposed sidewalks are shown in VDOT right -of -way, they must also be approved for acceptance by VDOT for future maintenance. Please contact David Pennock at 296 -5832 ext. 3432 if you have any questions. cc: 1 oF IL & tar a7 Irt IRGI:IP COUNTY OF ALBEMARLE The following facsimile message is being sent from: Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone: (434) 296 -5832 Fax: (434) 972 -4126 Date: July 5, 2005 Number of Pages (including cover): f Sent To: B. Aubrey Huffman Fax: (434) 979 -1681 and Associates Phone: (434) 979 -8121 Sender: David Pennock RE: Commonwealth Greenbrier Preliminary Site Plan Comments Division: Current Development Message: Planning, Engineering, and Water Service Authority comments attached. cc: Review Comments Project Name:Commonwealth - Greenbrier Center Preliminary — Non - residential Date Completed:Wednesday, July 06, 2005 Reviewer:Andrew Slack Department/Division /Agency: E911 Reviews Comments BEFORE FINAL PLAT SUBMITTAL THE APPLICANT SHOULD CONTACT THIS OFFICE WITH A LIST OF THREE (3) ROAD NAME RECOMENDATIONS FOR THIS SITE. Review Status:Requested Changes Page: 1.00 County of Albemarle Printed 01 Thursday, July 07, 2005 Review Comments Project Name:Commonwealth - Greenbrier Center Preliminary — Non - residential Date Completed:Wednesday, July 06, 2005 Reviewer:Jay Schlothauer Department/Division /Agency: Inspections Reviews Comments Based on plans dated June 13, 2005. Rearrange the barrier -free parking spaces at Lots A and B so that they are van - accessible. Review Status:Requested Changes Page: 1.00 County of Albemarle Printed 0 Thursday, July 07, 2005 of t rRGINIP, COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 July 7, 2005 Johnny Drumheller B. Aubrey Huffman and Associates, LLC P.O. Box 6124 Charlottesville VA 22906 RE: C.- C,1v`A ,C CrJ71_: Dear Sir or Madam: The Site Review Committee has reviewed the development proposal referenced above. Preliminary Comments for the following agencies, as applicable, are attached: Albemarle County Department of Community Development - Engineer Albemarle County Department of Building Code Enforcement and Zoning Services Albemarle County Department of Community Development - Planning Rivanna Water and Sewer Authority Albemarle County Department of Community Development — Geographic Data Services Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues which could affect approval of the proposed project. Please make the revisions that have been identified as necessary for preliminary approval by the Site Review Committee. If you choose not to make the requested revisions, please submit in writing justification for not incorporating such revisions. Submit seven full size copies and one 11" x 17" copy to the Department of Planning and Community Development. Responses to the attached comments of the Site Review Committee must be submitted by July 18, 2005. Failure to submit this information by this date will result in suspension of the review schedule. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Jvvi, David Pennock Senior Planner Attachments Cc: I °in a• I IRGI P COUNTY OF ALBEMARLE The following facsimile message is being sent from: Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone: (434) 296 -5832 Fax: (434) 972 -4126 Date: July 8, 2005 Number of Pages (including cover): 4 Sent To: B. Aubrey Huffman Fax: (434) 979 -1681 and Associates Phone: (434) 979 -8121 Sender: David Pennock RE: Commonwealth Greenbrier Preliminary Site Plan Comments Division: Current Development Message: VDOT comments attached. cc: C OIL COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 701 VDOT Way CHARLOTTESVILLE VA 22911 GREGORY A. WHIRLEY James S. Utterback, PMP ACTING COMMISSIONER Residency Administrator July 7, 2005 Glenn Brooks Department of Engineer and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject:Site Review Meeting Comments Dear Mr. Brooks: Below are VDOT's comments for the Site Plans reviewed at the July 7, 2005 Site Plan Review Meeting: SDP 2005 -00059 Town & Country Commercial Phase 1, Route 250: (Yadria Amarante) All accesses and roadways shall be designed in accordance with the current Subdivision Street Standards, The Minimum Standards for Entrances to State Highways and the Road Design Manual; Minimum right turn and taper per the AASHTO requires 250' of storage with 100' of taper; Intersection, entrance and roadway profiles, roadway curve data, drainage computations, and intersectional sight distances will be required. SDP 2005 -00057 Carman, Route 250: (David Pennock) All accesses and roadways shall be designed in accordance with the current Subdivision Street Standards, The Minimum Standards for Entrances to State Highways and the Road Design Manual; A minimum right turn and taper of 250' of storage with 100' of taper is required; Intersection, entrance and roadway profiles, roadway curve data, drainage computations, and intersectional sight distances will be required; Entrances design needs to comply with the previously approved plan for the adjacent Tip Top Property; Drainage swale behind the curb and gutter parallel to the roadway needs to be addressed. TRANSPORTATION FOR THE 21 CENTURY Glenn Brooks July 7, 2005 Page Two SDP 2005 -00061 Commonwealth — Greenbrier Center, Route 866: (David Pennock) Access shall be designed in accordance with the Minimum Standards for Entrances to State Highways; Entrance profile, drainage computations, and sight distances will be required and shown on the plans; Vicinity Map is incorrect and needs to properly identify the site location. SDP 2005 -00060 LDS Church, Route 649: (Francis MacCall) Access to the church is from a proposed private road being developed separately from this plan; The private road access shall be designed in accordance with the Minimum Standards for Entrances to State Highways. Initial private road entrance comments have been forwarded to the applicant; Drainage computations for the church site are under review and comments will be submitted when the review is complete. SUB 2005 -00186 The Village at Chestnut Grove, Route 663: (Steve Tugwell) The road in the subdivision is proposed to be private; Access to Route 663 shall be designed in accordance with the Minimum Standards for Entrances to State Highways; Recommend Minimum 25' ROW dedication across the entire road frontage; All lot shall access off of the internal road; Entrance profile, drainage computations, will be required and shown on the plans; Sight distances at the entrance have been checked in the field and exceed the minimum 500' required. Please show the correct measured distances on the plans; The plans show the 100' foot right turn taper as previously requested. SDP 2005 -00062 Oakleigh Townhomes, Route 631: (Stephen Waller) The roads are proposed as Private Roads. Access to the parcel will need to be designed in accordance with the Minimum Standards for Entrances to State Highways; The entrance requires a 100' right turn taper with 250' storage; The proposed waterline extension should be moved to the outer portion of the existing ROW; Entrance profile, drainage computations, and sight distances will be required and shall be shown on the plans. Glenn Brooks July 7, 2005 Page Three Please request the applicants submit a written description of the revisions when resubmitting for review. If you should have concerns with these comments, please discuss with this office prior to sharing with the applicants. S incerely, C. C. Proctor III Assistant Residency Administrator cc Alan Schuck, Steve Snell, Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell, Yadria Arnarante, David Pennock, Francis MacCall, Steve Tugwell, Stephen Waller, John Giometti, and Marshall Barron r COUNTY OF ALBEMARLE FIRE RESCUE ADMINISTRATION 460 Stagecoach Road, Suite F fp` Charlottesville, Virginia 22902 - 6489 1'' 1 Tel: (434) 296-5833 Fax: (434) 972 -4123 Memorandum TO: David Pennock FROM: James Barber DATE: July 8, 2005 RE: SDP 2005 00061 Commonwealth- Greenbrier Center David, I have had a chance to review the plans submitted and can offer the following continents on behalf of the Department of Fire Rescue. Indicate the location of fire hydrants. Hydrants must be within 400 feet of the building by way of a prepared Travel way. (Albemarle County Zoning Ordinance 32.7.6). Verify adequate fire flow is available. Required fire flow is 5000 GPM 20 PSI. (Albemarle County Zoning Ordinance 32.7.6). Please let me know if you have questions. OF ALg COUNTY OF ALBEMARLE The following facsimile message is being sent from: Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone: (434) 296 -5832 Fax: (434) 972 -4126 Date: July 12, 2005 Number of Pages (including cover): 2 Sent To: Steve Melton Fax: (434) 296 -3510 Phone: 979 -8181 Sender: David Pennock RE: Commonwealth Greenbrier Preliminary Site Plan Comments Division: Current Development Message: Fire /Rescue comments attached. CC: AL/3 County of Albemarle Department of Community Development Memorandum To:David Pennock From: Mark Chambers, Engineering Technician Division: Current Development Date:27 July, 2005 Subject: Commonwealth- Greenbrier Center Preliminary Site Plan David: Engineering reviewed the subject preliminary plat submitted on July 18, 2005. We do not recommend approval, but request the following changes to bring the preliminary site plan in compliance with County Code: 1. Construction of the retaining wall will result in encroachment of tax map 61W, parcel 03 -3A Please provide a letter of intent to grant a temporary grading easement from the owners of tax map 61W, parcel 03 -3A. (DSM, 1102). 2. An arrangement must be made with Albemarle County, General Services Department for work that must take place in Peyton Basin to construct the retaining wall and provide erosion and sediment control for the site. The applicant is currently working with the County on this requirement. 3. Please show the existing fiber optic cable that transects the north end of the parcel. 4. The applicant must receive approval from the Planning Commission of the Critical Slopes waiver request. Please contact me with any questions or concerns about the plan or the above comments. OF AL , f IkP County of Albemarle Department of Community Development Memorandum To:David E. Pennock, Senior Planner From:Mark Chambers, Current Development engineering review Date:27 July 2005 Subject: SDP200500061 Commonwealth Greenbrier Center, Critical Slope Waiver Request The critical slope waiver request has been reviewed. The engineering analysis of the request follows: Description of critical slope area and proposed disturbance: There are two areas of critical slope on the parcel: 1. Area 1 is .087 acres (3840 sq.ft.) located on the north end of the parcel and has an average gradient of 2.5'H : 1'V. Approximately 70% of area 1 is man made fill slope associated with the construction of Commonwealth Drive; 2. Area 2 is .05 acres (2440 sq.ft.) located along the west boundary of the parcel and has gradients ranging from 1.5'H : 1'V to 3'H : 1'V. It is undetermined if Area 2 critical slopes are man made or natural. The disturbance of these areas of critical slope will include filling, grading and construction of a retaining wall, for the purposes of creating parking area and 1 of the 3 proposed building sites. The disturbance of these areas of critical slope will enable the applicant to maximize the development potential of the parcel. Areas Acres Total site 1.33 ac. Critical slopes 14 10% of site Critical slopes disturbed 14 100% of critical slopes Compliance with Zoning Ordinance 18 -4.2: movement of soil and rock" The movement of soil and rock will be controlled through erosion and sediment control measures and construction of the retaining wall. excessive stormwater runoff' The disturbance of critical slopes is for development activity, which will create additional impervious area, resulting in increased stormwater runoff. The increased stormwater runoff will be detained to county and state standards in Peyton Basin. Peyton Basin is a county owned and operated regional detention basin located on the adjacent parcel. The parcel was donated to the county by the applicant in 1996 for the purpose of constructing a regional detention basin, with the agreement that at such a time the applicant developed the subject parcel, (subject of this waiver request) the basin could be used to control increased runoff with no additional cost to the applicant. It should be noted that the applicant is proposing to use Peyton Basin to meet stormwater quantity requirements only and is providing stormwater quality control on site and at their cost through the use of 6 Filterra, manufarctured BMPs. siltation" Inspection and bonding by the County will ensure siltation control during construction. Proper stabilization and maintenance will ensure long term stability. loss of aesthetic resource" The majority of the parcel including the areas of critical slopes are currently vegetated with early succession hardwoods and evergreens. The critical slope waiver will allow for the removal of more vegetation which could be considered a loss of aesthetic resource. septic effluent" This is not a concern as the site is serviced by public sewer. Based on the review above, there are no engineering concerns which prohibit the disturbance of critical slopes as shown. Engineering recommends approval of the critical slope waiver request. C frtoAt ea(t4.. fir 4c tee. ,t,p — 11 (\ co , J S s vs'n WA t l aS Gko" aA r 41-1.S OS" T4e l l.'s e 4 -e-eto racy r, Q - S ec i-f t tit' rv, - /U re_S c v l (E t7Fi.I u kf,/ o r l E f c Co As Tr U e it e te eft1' u !'e Svn car - CrJ fine E cti,k41 CtIck 1 ctrl°_ coivr rvc_ 1`QJ,