HomeMy WebLinkAboutSDP200700001 Review Comments 2007-01-29U F V J K (- A N I .
DEPARTMENT OF TRANSPORTATION
1601 Orange Road
Culpeper, Virginia 22701
David S. Ekern, P.E.
VirginiaDOT.org
COMMISSIONER
January 29th, 200
Mr. Glenn Brooks
Department of Engineering and Development
401 McIntire Rd.
Charlottesville, VA 22902
Subject: Site Review Meeting Continents February 1 st, 2007 site review meeting
Dear Mr. Brooks:
Below are VDOT's comments on the Site Plans for the February 1 st, 2007 Site Review Committee
Meeting:
SDP - 2007 -00001 Martha Jefferson Hosaital Preliminary (David Pennock
The design speed needs to be indicated on the plans. It appears that the plans are designed to a
25mph design speed. The minimum should be 30mph.
The desirable crossover spacing is be 500 feet and the minimum is 450 feet. Intersection "D"
does not provide enough distance between crossovers.
Sight distance lines need to be shown on the plans. The minimum intersection sight distance
is 355 feet for 30 mph design speed. Where the sight lines go outside the proposed R/W, an
easement will need to be provided and must stay clear of sight obstructions.
Road plans will need to be provided and include horizontal and vertical alignments and data,
typical sections, mainline and entrance profiles, pavement design with computations, and
drainage computations. The plans should also include projected traffic and dimensions of
features such as turn lanes.
All road plans, intersections with public and private roads, and entrances need to be designed
in accordance with VDOT's Road Design Manual, The Road and Bridge Standards, and the
Minimum Standards for Entrances to State Highways.
SDP - 2007 -00002 Meadows Expansion Preliminary (Summer Frederick
All connections to Rte. 1230 need to be designed in accordance with VDOT's Road Design
Manual and The Minimum Standards of Entrances to State Highways. The plans needs to
include all dimensions of proposed roads and entrances along with horizontal and vertical
data.
Tit ANSPORTATtOM EXf Er tE1i4E
4 m 5 1 rJ t1
Sight distances need to be shown on the plans.
All work within the VDOT R/W needs to be permitted by VDOT's Charlottesville Office.
The plan needs to provide pavement calculations and drainage calculations.
Sidewalks within the VDOT R/W need to include CG -12 detectable warning surface.
SDP- 2007 -00009 Westhall Phase V Lots 90, 91, 92 (Patrick Lawrence)
Lot 90 -- If a driveway is to be proposed on Park Road from this lot, the entrance needs to be
entirely outside of the radius between Park Road and Westhall.
Please request the applicants provide a written description of revisions with re- submissions. If you
have any questions or comments, please contact me prior to sharing these comments with the
applicants.
Sincerely,
Joel DeNunzio, P.E.
Residency Program Manager
VDOT Charlottesville Residency
434 - 293 -0011
cc Allan Schuck, Bill Fritz, David Benish, Juan Wade, Elaine Echols, Joan McDowell,
Judith Weigand, Margaret Maliszewski, David Pennock, Francis McCall, .Ton Sharp, Summer
Frederick, Patrick Lawrence, and John Giometti
oF ai.
County of Albemarle
Department of Community Development
Memorandum
To: David Pennock, Current Development planning and zoning review
From: Glenn Brooks, County Engineer
Date: 23 Feb 2007
Subject: Martha Jefferson Hospital, critical slope waiver request (SDP200700001)
The critical slope waiver request has been reviewed. The engineering analysis of the request follows:
Description of critical slope area and proposed disturbance:
These are hillsides and areas of former grading in Peter Jefferson Place.
Areas Acres
Total site 38.27 acres (new lot 11)
Critical slopes 5.29 14% of site
Critical slopes disturbed Almost
all
90% of critical slopes
Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable
alternative locations:
Most of these disturbances are exempt because they are part of the roadway grading for Peter Jefferson
Parkway and for Willis Drive and for the stormwater management and erosion control facilities necessary
for the site. In addition, these disturbances are part of an approved rezoning application plan. The layout
of these plans is such that reasonable alternatives to these disturbances are not possible without changes to
the rezoning.
The portions of criticial slopes that are not exempt (approximately 0.5 acres) are under parking areas and
buildings. Below, each of the concerns of the Zoning Ordinance is discussed for these remaining critical
slopes.
Compliance with Zoning Ordinance 18 -4.2:
movement of soil and rock"
The building and parking areas will replace slopes, and movement of soil should not be an issue.
excessive stormwater runoff'
Stormwater runoff will changes, as the slopes will be eliminated, and the stormwater plan will
eliminate excessive discharges.
siltation"
Inspection and bonding by the County will ensure siltation control during construction. Since the
slopes are mostly eliminated, long term stability should not be an issue.
loss of aesthetic resource"
Visibility from other areas of Albemarle was addressed with the rezoning.
septic effluent"
This neighborhood is serviced by public sewer.
Albemarle County Community Development
Engineering Review comments
Page 2 of 2
Based on the review above, there are no engineering concerns which prohibit the disturbance of the critical
slopes as shown.