SDP200700134 Application 2007-11-13
County of Al.- marle y� 7 Planning Application 1 TMP 06200-00-00-06300 owner(s): FARRELL, MATTHEW S Application # S©P200700134 Comrr Development Department, Zoning & Current Development Division 401 McIntire Road Charlottesville, VA 22902-4596 Voice : (434) 296-5832 Fax: (434) 972-4126 Legal Description ACREAGE Magisterial Dist. Rivanna Land Use Primary Residential -- Single-family (incl. modular homes) Current AFD Not in A/F District Current Zoning Primaryi Rural Areas House # Street Name Apt / Suite City State Zip Street Address 2110 STONY POINT RD CHARLOTTESVILLE 22911- 1 Entered By: Carla Harris on 11/13/2007 Application Type Site Development Plans Project: Farrell Property/Verizon Tier II PWSF - Final 5,420.00 1 Received Date 11/12/2007 Received Date Final Total Fees $ 790.00_ Submittal Date 11/12/2007 Submittal Date Final — - Total Paid $ 790.00 Closing File Date Revision Number Comments: Legal Ad Type Sub Application Date Comments Final - Non-residential - Commission 11/13/2007APPLICANT / 1 1 CONTACT• • Primary Contact Name Stephen Waller, AICP Phone # (434) 825-0617 street Address 536 Pantops Center, PMB 320 Fax # (757) 282-5811 City / State Charlottesville, Va Zip Code 22911-0000 E-mail stephen.waller@wirelessresources.co Cellular # ( ) - Owner/Applicant Name FARRELL, MATTHEW S Phone Street Address 2110 STONY POINT RD Fax # City / State CHARLOTTESVILLE VA zip code 22911- E -mail Cellular # Applicant -- - -- - Name Cellco Partnership d/b/a Verizon Wireless Phone # (434) 825-0617 Street Address 1831 Rady Court Fax # ( ) - City / State Richmond, Va zip code 23222-0000 E-mail _ Cellular Signature of Contractor or Authorized Agent Date 60.T Application for Site Development Plans and Site Plan Waiver SITE DEVELOPMENT PLANS SITE PLAN WAIVER O Preliminary Site Development Plan (Subject to Planning Commission Review) Site Plan Waiver O Residential = $1,190 plus $13/dwelling unit (Ordinance Section Number) = $270 O Non-residential = $1,580 plus $1311,000 sq. ft. of dev. 8 folded copies of sketch plait are I7 folded copies of plait are required required O Final Site Development Plan (Administrative Review) (1 Residential= $410 (1 Non-residential = $410 8 folded copies of plait are required far first submission OR (X) Final Site Development Plan (Subject to Planning Commission Review) ( ) Prior to preliminary approval = $1,130 17folded copies of plait are required (X) After preliminary approval = $790 — Tier II PWSF 8 folded copies of plait are required for first submission Two (2) ntvlars and two (2) paper copies ofplan are re uired -w signing o inal lau For all Preliminary Site Plans, Final Site Plans prior to preliminary approval, and Site Plan Waivers ( ) Tier 3 Groundwater Review = $400 plus $25 per dwelling unit (Required for all plans showing- a use that uses less than 2,000 gallons of water per day average) ( ) Tier 4 Groundwater Review = $1,000 (Required for all plans showing a use that uses greater than 2,000 gallons of water per day average) Project Name: Farrell Property / Verizon Tier II PWSF — ka' West \' Tax map and parcel: _06200-00-00-00630 Magisterial District: _Rivanna Zoning: _RA and EC Physical Street Address (if assigned): _2110 Stony Point Road Location of property (landmarks, intersections, or other): Heading north on Stony Point Road (State Route 20) approximately 720 feet north of the intersection with Vincennes Road on the west side of the road turn onto gravel driveway. Contact Person/Business Name (Who should we call/write concerning this project'?): _Stephen Waller, AICP Address _536 Panto s Center PMB 320 city _Charlottesville State _VA zip _22911_ Daytime Phone (434) _825-0617 Fax # (757) _282-5811 _ E-mail_stephen.waller@wirelessresources.com Owner of Record Matthew S. Farrel Address _2110 Stony Point Road city _Charlottesville State _VA zip T22911_ Daytime Phone (804) _465-0707 Fax # (_) E-mail Applicant (Who is the Contact person representing'?): _Cellco Partnership d/b/a Verizon Wireless Address _1831 Rady Court city _Richmond State VA zip _23222 Daytime Phone (434) _825-0617 Fax # ( ) E-mail FOR OFFICE USE ONLY SDP # Fee Amount /� Date Paid I111`•r r zy whot? _fin St t-� Receipt # 41" ` `{ Ck# P� -� i3y: County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Voice: (434) 296-5832 Fax: (434) 972-4126 5/1/06 Page I of 2 ( ) Residential Type of unit(s): # of building(s): Sq. ft. of building(s): # of units per building: Total # of units: Resulting density: Acreage of site: Acreage in open space: Acreage in roads: Average gallons of water used I Type of Development Intended use or justification for request: Please see attached Application Package Owner/Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5 (Preliminary Plan) or Section 32.6 (Final Plan) of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten (10) days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.3 as the case may be. For Final Plans Only: To the best of my knowledge, I have complied with Section 32.4.3.1 and obtained tentative approvals for all applicable conditions from the appropriate agencies. r4✓� f November 12, 2007 Signature of Owner, Contract Purchaser, Agent Date Stephen Waller 434-825-0617 Print Name Daytime phone number of Signatory 5/1/06 Page 2 of 2 (X) Non-residential (X) Commercial ( ) Industrial ( ) Quasi -Public Sq. ft. of building(s): 360 square feet Acreage of site: 2.95 acres Acreage in open space: N/A Acreage in roads: 743 s.L of new gravel ---- Average gallons of water used per day: _ N/A Intended use or justification for request: Please see attached Application Package Owner/Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5 (Preliminary Plan) or Section 32.6 (Final Plan) of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten (10) days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.3 as the case may be. For Final Plans Only: To the best of my knowledge, I have complied with Section 32.4.3.1 and obtained tentative approvals for all applicable conditions from the appropriate agencies. r4✓� f November 12, 2007 Signature of Owner, Contract Purchaser, Agent Date Stephen Waller 434-825-0617 Print Name Daytime phone number of Signatory 5/1/06 Page 2 of 2 Key West / Farrell Property Personal Wireless Services Application For a Tier II - Treetop Facility Located at 2110 Stony Point Road Charlottesville, VA 22911 Submitted by 1831 Rady Court Richmond, VA 23222 Contents • Introduction / Project Description • Site Photos • Antenna Specifications • Light Fixture Specifications INTRODUCTION/ NARRATIVE TIER 11 PERSONAL WIRELESS SERVICE FACILITY VERIZON WIRELESS "KEY WEST" - FARRELL PROPERTY Proiect Description: Cellco Partnership, operating as Verizon Wireless ("Verizon"), respectfully requests approval to allow installation of a Tier II Personal Wireless Service Facility (PWSF) on an approximately 2.95 acre parcel of land, located at 2110 Stony Point Road (State Route 20) in the Rivanna Magisterial District, and identified as Tax Map 62 / Parcel 63 (the "Property"). This proposed Tier II PWSF will be part of a network of facilities intended to provide seamless Personal Communications Services to residents in the Key West area and travelers along Route 20 between Pantops Mountain and the Stony Point. The proposed PWSF facility will be contained within a 2,500 square foot lease area on the Property and the site is located at an elevation of approximately 489.5 feet Above Mean Sea Level (AMSL). The proposed PWSF will include a metal monopole, with a top height of 120.5 feet (approximately 610 feet AMSL) that will be fitted with three (3) flush -mounted antennas, a 2 -foot long lightning rod and coaxial cables that will be run vertically inside the monopole. All ground-based transmitting equipment and an emergency generator will be housed within a prefabricated equipment shelter measuring 12' x 30.42' x 10.58' (W x L x H). The monopole and antennas will be painted with Sherwin Williams Java Brown - 46090, which is a matte enamel color that has been previously approved as an appropriate color for Tier II facilities at other sites in Albemarle County. Network Objectives: Verizon recently secured a license from the Federal Communications Commission to provide Personal Communications Services within a new market that includes the County of Albemarle, City of Charlottesville and other surrounding counties. These services range from phones with voice, data, text, video and GPS capabilities, to wireless broadband solutions for personal and business computer systems. Verizon does not currently offer any service options locally, providing limited services within this market only to existing customers from other areas through roaming agreements with another wireless carrier. There had been no opportunities for Verizon to offer the full range of services until the FCC license was obtained. Verizon has identified several sites throughout the market that will be integral to establishing this service. Once all of the proposed sites are "on -air," Verizon will be able to provide potentially seamless in -building, in -car and on -street coverage throughout the market. By providing coverage within this market, it is Verizon's objective to ensure that the full range of services will be available to existing customers, while also allowing an additional, competitive option for access to wireless services by future customers. The specific facility proposed with this application will establish in -building coverage for residences in the Key West development and the other nearby dwellings along Route 20. It will also support in -car coverage for customers traveling on Route 20 by connecting its service with the other antenna sites that will be installed toward the north approaching Stony Point and south toward Pantops. Verizon Wireless PWSF Page 1 Key West (Farrell) Character of the Area: The Property is zoned Rural Areas (RA) and located in the Entrance Corridor (EC) overlay district. All of the surrounding properties are zoned Rural Areas. The proposed PWSF should not substantially impact the rural character of the area because it is surrounded by tall trees that will assist in screening views of its lower section from surrounding roads and properties. Additionally, the brown ground equipment will be screened from the nearest parcel line behind a wooden privacy fence. The proposed facility will be located approximately 360 feet north of the right-of-way for Route 20, in an area that is heavily wooded. Access to the facility will be taken from an existing private gravel driveway that begins on the western side of Route 20. The road then runs past the property owner's dwelling up a slight grade and into the woods. The nearest off-site dwelling unit to this site is approximately 170 feet southwest of the proposed PWSF site and there is an existing cemetery on the Property approximately 65 feet northwest of the site. Although Route 20 is a scenic byway, the site is more than 200 feet away from its right of way. None of the other resources that are defined as avoidance areas in Section 3.1 of the zoning ordinance are located on this Property. Compliance with Section 5.1.40 of the Zoning Ordinance: The County's specific design criteria for Tier 1I Facilities, set forth in Section 5.1.40(d), are addressed as follows: 5.1.40(d)(1) - The facility shall comply with subsection 5.1.40(b) and subsections 5.1.40(c)(2) through (9). ♦ Subsection 5.1.40(b) (1-5): With an exception of the monopole's distance from the southern boundary line of the Property, which is 55.4 feet, the proposed PWSF will be in compliance with all setback regulations, area and bulk regulations and minimum yard requirements. In accordance with Section 5.1.40(b)(2), Verizon Wireless is in the process of obtaining a "fall -zone" easement on the adjoining parcel that shares its southwestern boundary (Tax Map 62 / Parcel 65) to address the tower setback issue. The easement will account for the remaining 64.5 feet of difference between the monopole's height and its distance from the affected property line. After execution and recordation, the "fall -zone" easement will be filed with the Department of Community Development prior to the submittal of a building permit application. The attached site drawings, antenna and equipment specifications are being provided to demonstrate that the PWSF regulations and the relevant site plan requirements, set forth in Section 32 of the zoning ordinance, have been accounted for in this application. ♦ Subsection 5.1.40(c)(2): The proposed monopole does not require the installation of guy wires, nor will it be fitted with any whip antennas without any further County approvals. The proposed grounding rod complies with the County's size requirements. The facility will only have one outdoor light fixture attached to the proposed shelter which will only be used by Verizon's technical staff during times when maintenance of the site is undertaken. Verizon is currently in the process of securing a design for a retrofit shield for the original light or a replacement light fixture to ensure that the facility will be in full compliance with Section 4.17 of the zoning ordinance prior to construction. Verizon Wireless PWSF Page 2 Key West (Farrell) ♦ Subsection 5.1.40(c)(3): The proposed antenna configuration will consist of one sector with three panel antennas (Anphenol Antel Model # BXA-185085/12) that measure 72.44" x 6.06" x 4.13", giving each antenna an area of approximately 439 square inches. These antennas will be installed using "pipe -mounts" that will allow for any required amount of down -tilting without exceeding the County's requirements for flush -mounts (12 -inches maximum between the face of the monopole and the face of the antenna). All antennas will be painted to match the color of the monopole. ♦ Subsection 5.1.40(c)(4 and 5): Installation of the facility and extension of its access from the existing driveway will not require the removal of five (5) trees located within a 50 -foot radius of the facility and a few other trees outside of that radius. With the extensive amount of vegetation remaining, the removal of those trees should not increase the visibility of the proposed PWSF. Verizon has already contracted Van Yahres Tree Company to provide a tree conservation plan that will be prepared by a certified arborist. In order to ensure there is no significant impact to any of the trees that will remain, the conservation plan will be completed prior to the submittal of a building permit for this facility. Recommendations of the tree conservation plan will then be integrated into the construction process and followed on all portions of the Property that will be affected by the construction of Verizon's facility. ♦ Subsection 5.1.40(c)(6): Should use of the antenna site in this location become discontinued at anytime in the future, Verizon and/or its assignee(s) will be required to remove the facility within 90 days. ♦ Subsection 5.1.40(c)(7): Verizon shall submit an annual report updating the user status and equipment inventory of the facility in the required time period. ♦ Subsection 5.1.40(c)(8): No 2:1 or greater slopes will result from the construction of this facility. Subsection 5.1.40(c)(9): Because the facility will be located where ground equipment could be partially visible from an adjacent property owner's yard, Verizon is proposing the installation of a wooden screening fence around the facility. The proposed fence will only surround the ground equipment shelter, tower and adequate area as needed to carry out service and maintenance activities, not the entire lease area. Because the proposed fence will be painted Java Brown (SW #6090) it should not be detrimental to the character of the area or to the general welfare, safety and health of the surrounding properties and their residents. Section 5.1.40(d)(2) - The site is heavily wooded and none of the trees to be removed appear to be instrumental in establishing the height of the facility or screening it from adjacent parcels and roadways. The remaining tall trees near the site will assist in screening brown monopole and allow it to blend into its surroundings. The shelter will not be visible from the nearby road, and it will be enclosed within a fence in order to screen it from the adjacent parcel lines. • Section 5.1.40(d)(3) - Although the Property is shares its north, west and south boundary lines with Route 20, which is a scenic byway, the PWSF will be far enough away so that it should not impose any adverse impacts upon that resource. Verizon Wireless PWSF Page 3 Key West (Farrell) • Section 5.1.40(d)(4) - There are no other PWSF's within 200 feet of the site of the proposed facility. Section 5.1.40(d)(5) - The monopole will have a base diameter that is no greater than 30 inches and a top diameter that is no more than 18 inches. Section 5.1,40(d)(6) - Verizon is requesting permission to install a monopole that will be nearly 10 feet higher than the tallest nearby tree. The reference tree has been identified as a 48" caliper Triple Poplar tree (approximately 600 feet AGL) with a dripline that is within I -foot of the proposed monopole location. This site is situated in an area that is rather level, so there will not be a need for any significant grading. Due to the density of the wooded area surrounding the site and outlying areas with additional tall trees that will assist in screening visibility of the monopole from nearby properties and roadways, Verizon is requesting permission to install a monopole that will be 10 feet higher than the tallest tree. Verizon anticipates that there will not be any material difference in adverse impacts to resources identified in the county's open space plan caused by a monopole at the proposed height, rather than seven (7) feet taller than the reference tree. • Section 5.1.40(d)(7) - The monopole and all antennas will be painted Sherwin Williams Java Brown #6090. This is a color that has been applied to previously approved PWSF monopoles. The prefabricated shelter that will be installed at the facility has siding that is a natural dark brown, earth -tone color with a stone aggregate finish. • Section 5.1.40(d)(8) - All coaxial cables and service lines running vertically from the transmitting equipment to the antennas will be located inside the monopole. • Section 5.1.40(d)(9-13) - Verizon has reviewed and understands all of the remaining criteria for Tier I1 Personal Wireless Service Facilities and will provide any additional information or assistance to ensure that these standards are met. Conclusion: Verizon Wireless is confident that the proposed Personal Wireless Service Facility meets the design criteria for approval of a Tier 11 facility and does not conflict with the goals and objectives of the Comprehensive Plan. The approval of this PWSF application will contribute to the deployment of a highly reliable personal communications system in this new market. The proposed site will help to provide nearby Albemarle County residents and others traveling on Route 20 an additional option for high quality personal communications services. Sincerely, Stephen Waller, AICP Site Development Consultant Verizon Wireless, Charlottesville Market Verizon Wireless PWSF Page 4 Key West (Farrell) SITE PHOTOS View southwest toward the reference. tree V to the tops of the trees ahoy e the site — Viexx to east ol'trees around the ocrimeter of'ti,itc View t0 the c 11'(1111 ollisidt, I11`Iho \"7411ldp(l A1'P;a 111xv:11 onto 7(1 IT' V Hel with Route 20 ANTENNA SPECIFICATIONS Mechanical specifications B�-7 85085�,� 2 Length 1840 mm 72.44 in C F 40 Width 154 mm 6.06 in When ordenn re t 11 Depth 105 mm 4.13 in al Weight 5.897 kg 13 lbs Wind Area Fore/Aft 0.283 m2 3.05 ft2 Side 0,195 m2 2.1 ft2 Rated Wind Velocity (Safety factor 2.0) >237 km/hr >148 mph Wind load @ 100 mph (161 km/hr) Fore/Aft 460 N 103.4 lbs Side 372 N 83.5 lbs Antenna consisting of aluminum alloy with brass feedlines covered by a UV safe fiberglass radome. Mounting & Downtilting: Wall mounted or pole tower mount with mounting brackets. Mounting bracket kit #26799997 Downtilt bracket kit #26799999 The downtilt bracket kit includes the mounting bracket kit. Electrical specifications Frequency Range 1850-1990 MHz Impedance 5052 3) Connector NE, E -DIN t> VSWR <_1.4:1 Polarization Slant t 45- Isolation Between Ports Gain 2) Power Rating Half Power Angle H -Plane E -Plane Electrical Downtilt Null Fill Lightning Protection < -30 dB 18 dBi 250 W 85° 5° 4- 5% Direct Ground Patented Dipole Design: U.S. Patent No. 6,597,324 82 1) TYPical Values 2) Power Rating limited by connector only. 3)NE indicates an elongated N Connector. E -DIN indicates an elongated DIN Connector. 4) The antenna weight listed above does not include the bracket weight. improvements to mechanical and/or electrical performance of the antenna may be made without notice. Radiation -pattern'! -110 -100 -90 -80 120 70 0 60 50 40 -00 s0 -30 -160 -20 -n0 to 180 _ - 3S 3026 5ro 1s 1a 5 0 170 10 160 20 150 30 140 40 30 uo so ,m 100 s0 60 70 60 Horizontal _1.10.100 -90 -80 -70 130 £0 so -140 -00 30 60 -20 -170 to 160 - - 0 1701 , ,o 160 20 150 30 140 130 1 l 40 120 50 110 — sa 100 190 80 70 Vertical Radiation patterns for all antennas are measured with the antenna mounted on a fiberglass pole. Mounting on a metal pole will typically improve the Front -to - Back Ratio. CF Denotes a Center -Fed Connector. .y1-01 u1ive rtocKtord, IL 61109 Toll -Free (888) 417-9562 Tel. (815) 399-0001 Fax. (815) 399-0156 Email: antel@antelinc.com www.antelinc.com g, pace — with connector type. Amphenol Antel's Exclusive 3T (True -- Transmission Line Technology) Antenna Design: • Watercut brass feedline assembly for consistent performance. • Unique feedline design eliminates the need for conventional solder joints in the signal path. • A non -collinear system with access to every radiating element for broad bandwidth and superior performance. • Air as insulation for virtually no internal signal loss. This Amphenol Antel antenna is under a five-year limited warranty for repair or replacement. Antenna available with center -fed connector only. Amphenol UThenteUnc. nw. Tezt.tn, Cmc . Revision Date: 12/4/06 LIGHTING SPECIFICATIONS IA L/THOVIA L/GHT/NG' FEATURES & SPECIFICATIONS INTENDED USE For entrances, loading docks, walkways and vehicle ramps CONSTRUCTION Rear housing is rugged, corrosion -resistant, die-cast alummme. Corrosion -resistant ex- ternal hardware includes slotted hex -head and tamperproof fasteners FINISH Dark Bronze (DDB) corrosion resistant polyester powder OPTICAL SYSTEM Reflector is finished in white thermoset polyester powder, electrostatically applied. Front housing and refractor are one-piece, injection -molded, UV -stabilized polycarbonate Standard finish an opaque portion of front cover and back housing is dark bronze poly- ester enamel. Refractor is sealed and gasketed to inhibit the entrance of outside con- taminants. ELECTRICAL SYSTEM 70-15OW is high -reactance, high power factor Encased -and -potted solid-state ignitors. 175W is constant -wattage autotransformer Ballast is copper -wound and 100% factory - tested. Meets ANSI standards and is UL listed Electrical components are mounted on back housing. (For 50 hertz availability, consult factory). Porcelain, horizontally-oriented, medium -hale (150W) or mogul -base (175W) socket with copper alloy, nickel -plated screw shell and center contact. UL listed (medium base 660W, 600V, mogul base 1500W, 600V). Both are 4KV pulse -rated INSTALLATION Top 3/4" threaded wiring access Back access through removable 3/4" knockout. Feed- thru wiring can be achieved by using a condulet tee. Mount on any flat, vertical surface LISTING UL listed suitable for wet locations. UL Listed to US and Canadian safety standards )see Options) NOM Certified (see Options). IP64 rated in accordance with IEC Standard 529. NOTE: Not recommended for use in car wash interior applications. Catalog Number Notes Type Specifications Height: 15-7/16" (39.2cm) Width: 16-1/8" (41cm) Depth: 7-3/4" (19.7cm) Weight: 16 lbs. (7 kg) Wall Packs TWP METAL HALIDE 70W, 100W, 150W, 175W 8' to 15' Mounting ORDERING INFORMATION Example: TWP 175M 120 LPI Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog numbers (shipped separately) TWP Series Wattage/lamp Voltage Options TWP 70M 120 Shipped installed in fixture Architectural colors (optional) lo0M' 2082 SF Single fuse (120, 277, 347V)° DBL Black 150M11e 2402 DF Double fuse (208, 240, 48OV)4 DMB Medium bronze 175M 277 EC Emergency circuit5' DWH White 347 QRS Quartz restrike system'.',' DNA Natural aluminum 4802 CR Enhanced corrosion -resistance DSS Sandstone TBI CRT Non-stick protective coating' TBV1011 PE Photoelectric cell, button type'' LPI Lamp included L/LP Less Lamp LS Lamp support (mogul socket only) FS Full shield WG Wireguard SCWA Super CWA Pulse Start Ballast NOTES: CSA Listed and labeled to comply with Canadian 1 Not available480V. Standards" 2 Not available in Canada NOM NOM Certified (Consult factory) 3 Optional multi -tap ballast (120, 208, 240, 277V) In canaria 120, 277, 347V; ships as 120/347. 4 Not available with multi -tap ballast. 5 Lamp not included. Accessories 6 Quartz lamp wattage not to exceed ballast wattage rating. 7 Black finish on housing only. Order as separate catalog number 8 May be ordered with SCWA. RK1 PEB1 Photoelectric control kit (120V) 9 QRSTD is available for select wattages; consult factory. RK1 PEBt CSA Photoelectric control kit (120V only) 10 Optional 5 -tap ballast(120,208,40,2277,480V) RK1 PEB2 Photoelectric control kit (208,240,277V) 11 Only available with 175M RKt PE83 CSA Photoelectric control kit (347V) 12 Not available with TBV. RK1 TWPFA FS Field installable full shield for cutoff Outdoor and Special Environments Sheet #:TWPM SE HID -240 TWP Metal Halide Wall Packs Coefficient of Utilization Initial Footcandles TWP 70M Test Report no. 97021601 Coefficients of utilization 2 L CA 1 L 6 0 c 0 2 E 1 1 0 2 c 5 3 U .2 C ° 4 0 1 5 0 1 2 3 4 5 6 Distance in units of mounting height 70W, metal halide lamp, horizontal lamp ori- entation, 10' mounting height, 5,200 rated lumens. Total fixture efficiency: 50.7% ELECTRICAL CHARACTERISTICS TWP 175M Test Report no. 94121102 Coefficients of utilization 2 r � 1 t S 0 5 0 1 E 2 0 1 2 .E .5 c 2 — 3 U 6 4 1 in 5 0 1 2 3 4 5 6 Distance in units of mounting height 175W, metal halide lamp, horizontal lamp orientation, 12' mounting height, 14,000 rated lumens. Total fixture efficiency: 53% ifA L/THO/V/A L/GHT/NGS Lithonia Lighting AnI-4, CU VBrandsCompany outdoor Lighting One Lithonia Way, Conyers, GA 30012-3957 Phone: 770-922-9000 Fax 770-918-1209 Sheet #: TWPM_SE n1989 Acuity Lighting Group, Inc., Rev. 4/06 www.hthonia.com Line current Primary Primary (amps) dropout Input Power Regulation Wattage/ballast voltage start/operating voltage watts factor (%) Line V = Lamp lumens 120 1.20/1.15 75 Mounting Height Correction Factor 100 XHP 208 0.70/0.60 130 130 90+ ±5% = ±10% (Multiply the fc level by the correction factor) 240 0.61/0.55 150 10' 12' 277 0.55/0.45 165 loft =1.44 347 0.46/0.38 235 15 ft. = .44 15 ft. _ 120 175CWA 208 1.10/1.80 70 115 .64 20 ft. = .25 20 ft.= .36 Peak -lead 240 .64/1.10 .55/.90 132 210 90+ ±10% = ±7% 25 ft.= .16 25 ft. = 23 Autotransformer 277 .481.78 150 480 .22/.45 264 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences Existing Mounting Height 2 between laboratory data and actual field measurements. Dimensions and specifications on this sheet are ( ) = Correction Factor based on the most current available data and are subject to change without notice New Mounting Height ifA L/THO/V/A L/GHT/NGS Lithonia Lighting AnI-4, CU VBrandsCompany outdoor Lighting One Lithonia Way, Conyers, GA 30012-3957 Phone: 770-922-9000 Fax 770-918-1209 Sheet #: TWPM_SE n1989 Acuity Lighting Group, Inc., Rev. 4/06 www.hthonia.com