HomeMy WebLinkAboutSDP200700158 Review Comments 2008-01-04Application #: — SDP200700158 iShort Review Comments Project Name:lVest Property/ Verizon Tier II PWSF - Final J [Personal Wireless Facility Date Completed:12/26/2007 Reviewer:Andrew Slack E911 Review Status:No Objection Reviews Comments: NO OBJECTION. Date Completed:01/07/2008 Reviewer:Gerald Gatobu CDZCD Review Status:Requested Changes Reviews Comments: Site Review held on 1/10/08. Height of the pole to be reduced per balloon test. Critical slopes waiver request needed per section 4.2.5.A (Revision deadline is 01/21/2008) Date Completed:01/07/2008 Reviewer:Max Greene Engineer Z &CD Review Status:No Objection Reviews Comments: Plan appears to require a critical slope waiver. Please request a critical slope waiver. This project does not appear to exceed 10,000 square feet of land disturbance. Should the Water Protection Inspector find the total site work exceeds the State E &SC limit of 10,000 square feet, then site work may be delayed while an erosion and sediment control plan is reviewed and approved. Please include all proposed work in the final site _plan. Date Completed:12/21/2007 Reviewer:Margaret Maliszewski ARB Review Status:No Objection Reviews Comments: It appears that the development proposed on parcel 43C1 falls outside the Entrance Corridor because it is located more than 500' from the Route 29 right -of -way. I have confirmed with the applicant that no substantial work is proposed on the adjacent parcel (43C). Consequently, ARB review is not required. Date Completed:01/29/2008 Reviewer:Philip Custer Engineer Z &CD Review Status:No Objection Reviews Comments: Date Completed:01/04/2008 Reviewer:Scott Clark Planning Review Status:Pending Reviews Comments: Rural Areas comments: This proposal does not impact any known conservation easements or Agricultural - Forestal Districts. Page: 1.00 County of Albemarle Printed On Wednesday, May 28, 2008 l t NJ! COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 DATE: 01 10 2008 Stephen Waller 536 Pantops Center PMB 320 Charlottesville, VA, 22911. RE: SDP - 2007 - 000158 Vest Property/ Verizon Tier I1 PSWF- Final. Dear Sir, The Site Review Committee has reviewed the development proposal referenced above. Preliminary comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Division of Zoning & Current Development (Planner) Albemarle County Division of Zoning & Current Development (Engineer) Albemarle County Division of Planning (Principle Planner ARB) Albemarle County Division of Planning (Principle Planner Rural Area) Albemarle County Division of Inspections (Building Official) Virginia Department of Transportation (VDOT). Albemarle County Service Authority (ACSA). Albemarle County Fire and Rescue. Albemarle County Geographic and Data Services (GDS) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that could affect approval of the proposed project. Please make the revisions that have been identified as necessary for preliminary approval by the Site Review Committee. If you choose not to make the requested revisions, please submit in writing justification for not incorporating such revisions. Submit eight (8) full size copies and one (1) 11" x 17" copy to the Department of Community Development including responses to each of the attached comments of the Site Review Committee by Monday January 21st 200 Failure to submit this information by this date will result in suspension of the review schedule. Review will resume when revisions are submitted along with a reinstatement fee of $65. Please contact me at your earliest convenience if you have questions or require additional infonnation. Sincerely, Aar arALII,01 Gerald GatobuCount Senior PlannerYofAlbemarleDepartmentofCoCurrentDmmunityDevelopmentevelopm401McIntireRoadCharlottesville, VAPhone:22902.4596 Fax: 434)296 -5832 Ext 3385434)972.4126 al /ic.ti HI I 41t !7(f^1 P ' County of Albemarle Department of Community Development Memorandum To:Gerald Gatobu, Current Development planning and zoning review From:Phil Custer, Current Development engineering review Date:29 January 2008 Subject: Vest Property, Verizon Teir II PWSF; critical slope waiver request (SDP- 2007 - 00158) The critical slope waiver request has been reviewed. The engineering analysis of the request follows: Description of critical slope area and proposed disturbance: The critical slope disturbance on parcel 109 -43C 1 will be needed for the construction of the cell tower, fenced enclosure, and access path. The disturbed critical slope is an area of mature hardwood trees sloping towards the house at approximately 30 %. Areas Acres Total site 2.85 acres approximately Critical slopes 2.42 85% of site Critical slopes disturbed 0.10 4% of critical slopes Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable alternative locations: The disturbance to construct the driveway to the fenced enclosure is exempt for the critical slope requirements. 4.2.6c] The combined area of the exempted critical slope disturbance (which has been included in the above calculations) is 0.03 acres. This area is approximately 30% of the critical slope disturbance. Compliance with Zoning Ordinance 18 -4.2: movement of soil and rock" Construction of the building and other site features will most likely require a temporary increased flow down the critical slopes during a rain event. Movement of soil can be caught with an appropriate sediment trapping measure before site runoff enters the existing stormwater system. excessive stormwater runoff' The changing of site characteristics will increase storm runoff by an insignificant amount. siltation" Proper stabilization and maintenance will ensure long term stability. loss of aesthetic resource" The critical slope disturbance is located 500ft from Maury's Lane, the nearest public space. The applicant has performed a tree survey of the area and appears to have made above - average efforts to impact as few existing trees and slopes as possible. septic effluent" This site will not require septic facilities. Based on the review above, there are no engineering concerns with the proposed disturbance to critical slopes that cannot be alleviated with the standard engineering and erosion control practices proposed by the applicant. Application #:SDP20070015L Short Review Comp ants Project Name: Vest Property/ Verizon Tier II PWSF - Final Personal Wireless Facility Date Completed:12/26/2007 Reviewer:Andrew Slack E911 Review Status:No Objection Reviews Comments: NO OBJECTION. Date Completed:01/07/2008 Reviewer:Max Greene Engineer Z &CD Review Status:No Objection Reviews Comments: Plan appears to require a critical slope waiver. Please request a critical slope waiver. This project does not appear to exceed 10,000 square feet of land disturbance. Should the Water Protection Inspector find the total site work exceeds the State E &SC limit of 10,000 square feet, then site work may be delayed while an erosion and sediment control plan is reviewed and approved. Please include all proposed work in the final site plan. Date Completed:12/21/2007 Reviewer:Margaret Maliszewski ARB Review Status:Requested Changes Reviews Comments: It appears that the development proposed on parcel 43C1 falls outside the Entrance Corridor because it is located more than 500' from the Route 29 right -of -way. I have confirmed with the applicant that no substantial work is proposed on the adjacent parcel (43C). Consequently, ARB review is not required. Date Completed:01/04/2008 Reviewer:Scott Clark Planning Review Status:Pending Reviews Comments: Rural Areas comments: This proposal does not impact any known conservation easements or Agricultural - Forestal Districts. Page: 1.00 County of Albemarle Printed On: Monday, January 07, 2008 May 12, 2008 Wireless Resources Inc. c/o Stephan Waller 536 Pantops Center PMB #320 Charlottesville, VA 22911 Dear Mr. Waller, After visiting the location for a tower on the Covesville /Vest property site and examining the zoning documents (revised 4- 10 -08) the tree protection should be adequate as proposed. There will be significant root disruption on the uphill side with the installation of the retaining wall. including the reference tree ( #498). To reduce the likelihood of decline due to construction, I would recommend injected fertilization with additional Mycorrhizae to aid in root system recovery. If you have any further questions please contact me at (434) 982 -8733. Sincerely. Dave Rosene Certified Arborist