Loading...
HomeMy WebLinkAboutSDP200700118 Application 2007-10-23County of A, ,3marle Planning Application 1 TMP 09800 - 00-00-02200 Owner(s): MAWYER, VIOLET P Application # SOP200700118 Legal Description I ACREAGE Magisterial Dist. ISamuel Miller Comr +y Development Department, Zoning & Current Development Division 401 McIntire Road Charlottesville, VA 22902 -4596 Voice : (434) 296-5832 Fax :(434)972 -4126 Land Use Primary I Residential -- Single- family (incl. modular homes) Current AFD INot in A/F District Current Zoning Primary I Rural Ar House # Street Name Apt / Suite City State Zip Street Address 4 THACKERS LN NORTH GARDEN 22 - Entered By: Carla Harris on 1012312007 Application Type Site Development Plans Project: Mawyer P / Verizon Ti II PW - Final l 5 ,343.00 Received Date 10/22/2007 Received Date Final Total Fees $ 790.00 Submittal Date 10/22/2007 Submittal Date Final Total Paid $ 7 Closing File Date Revision Number Comments: Legal Ad Primary Contact Name Stephen W AICP Phone # ( 434) 825 -0617 Street Address 536 Pantops Center, PMB 320 Fax # ( 757) 282 -5811 City / State Charlottesville, Va Zip Code 22911 -0000 E -mail stephen .wailer @wirelessresources.co Cellular # Owner /Applicant Name MAWYER, VIOLET P Phone # Street Address 6093 PLANK RD Fax # ( ) - City / State AFT VA Zip code 22920- E -mail Cellular # Applicant I Name Cellco Partnership d /b /a Verizon Wireless Phone # ( 434) 825 -0617 Street Address 1831 Rady Court Fax # ( ) - City / State Richmond, Va Zip Code 23222 -0000 E -mail Cellular # Signature of Contractor or Authorized Agent Date App;tcation for Site Development Plans and Site Plan Waiver J M SITE DEVELOPMENT PLANS SITE PLAN WAIVER Preliminary Site Development Plan (Subject to Planning Commission Review) Site Plan Waiver Residential = $1,190 plus $13 /dwelling unit Ordinance Section Number) = $270 O Non - residential = $1,580 plus $1311,000 sq. ft. of dev.8 folded copies of sketch plan are 17folded copies ofplan are required required Final Site Development Plan (Administrative Review) Residential= $410 O Non - residential = $410 8 folded copies ofplan are requiredfor first submission OR X) Final Site Development Plan (Subject to Planning Commission Review) Prior to preliminary approval = $1,130 l7folded copies o /an are required X) After preliminary approval = $790 - Tier 11 PWSF 8 folded copies ofplat are required for first submission Two 2) mylars and two 2) paper copies ofplan are required or signing offinal plait For all Preliminary Site Plans, Final Site Plans prior to preliminary approval, and Site Plan Waivers Tier 3 Groundwater Review = $400 plus $25 per dwelling unit Required for all plans showing a use that uses less than 2,000 gallons of water per day average) Tier 4 Groundwater Review = $1,000 Required for all plans showink a use that uses tLreater than 2,000 - allons of water per daP average) J Project Name: Mawver Property /Verizon Tier II PWSF - "Thackers Lane" Tax map and parcel: 09800 -00 -00 -02200 Magisterial District: Samuel Miller Zoning: RA and EC Physical Street Address (if assigned): 4921 Thackers Lane Location of property ( landmarks, intersections, or other): Take U .S. Route 29 south for approximately 10 miles south of 1 - underpass, turn left (east) onto Thackers Lane, then turn right past white house following gravel road to the site. Contact Person /Business Name (Who should \ie callAN rite concerning this project' ?): Stephen Waller, AICP Address 536 Panto s Center PMB 320 city Charlottesville State VA zip 22911 Daytime phone (434) 825 -0617 Fax # (757) 282 -5811 1 -mail stephen .waller(a Owner of Record Violet P Mawver Address 6093 Plank Road _ _ cite - Afton State VA _ - Zip 22920 Daytime Phone (434) 823 -4562 Fax # (_) [ Applicant ( Who is the contact person representing?): Cellco Partnership d /b /a Verizon Wireless Address 1831 Rady Court city Richmond _ _ State VA zip 23222 Daytime Phone (434) 825 -0617 Fay # ( ) E-mail FOR OFFICE USi'. ONLY SDP # Fee Amount $ ( G' Date Paid fly %Nho'? ! C X'1 - — Receipt # e — -- - - C'k# ! B}. ° County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Voice: (434) 296 -5832 Fax: (434) 972 -4126 1 /06 Page I oft Type of Development Residential Type of unit(s): of building(s): Sq. ft, of building(s): of units per building: Total # of units: Resulting density: Acreage of site: Acreage in open space: Acreage in roads: Average -allons of water used per day: X) Non - residential X) Commercial Industrial Quasi- Public Sq. ft. of building(s): 240 square feet Acreage of site: 48.83 acres Acreage in open space: N/A 2.307 s.f. of gavelAcreageinroads Average gallons of water used per day: _ N/A Intended use or justification for request: Please see attached Application Package Owner /Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5 (Preliminary Plan) or Section 32.6 (Final Plan) of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten (10) days of submittal as provided in Section 32.42.1 or Section 32.4.3.3 as the case may be. For Final Plans Only: To the best of my knowledge, I have complied with Section 32.4.3.1 and obtained tentative approvals for all applicable conditions from the appropriate agencies. Signature of Owner, Contract Purchaser, Agent October 22, 2007 Date Stephen Waller Print Name 434 - 825 -0617 Daytime phone number of Signatory 5/1/06 Paflc 2 of 2 Thackers Lane / Mawyer Property Personal Wireless Services Application For a Tier II - Treetop Facility Located at 4921 Thackers Lane North Garden, VA 22959 Submitted by 1831 Rady Court Richmond, VA 23222 Contents Introduction / Project Description Site Photos Antenna Specifications Light Fixture Specifications INTRODUCTION/ NARRATIVE TIER II PERSONAL WIRELESS SERVICE FACILITY VERIZON WIRELESS THACKERS LANE" - MAWYER PROPERTY Project Description Cellco Partnership, operating as Verizon Wireless ( "Verizon "), respectfully requests approval to allow installation of a Tier 11 Personal Wireless Service Facility (PWSF) on a parcel of land located at 4921 Thackers Lane and identified as Tax Map 98 - Parcel 22 (the Property'). The Property is comprised of 43.83 acres located in the Samuel Miller Magisterial District in Albemarle County. The proposed PWSF facility will be contained within a 3,600 square foot lease area on the Property. The site is located at an elevation of approximately 855.18 feet Above Mean Sea Level (AMSL). The proposed PWSF will include a metal monopole, with a top height of 131 feet (1,345 feet AMSL) that will be fitted with three (3) flush- mounted antennas, a 246ot long lightning rod and coaxial cables that will be run vertically inside the monopole. All ground -based equipment will consist of transmitters and radios to be housed within a site - built "knockdown" equipment shelter measuring 12' x 20 x 10.92' (W x L x H), and a stand- alone emergency generator. The monopole and antennas will be painted with Sherwin Williams Java Brown - #6090, which is a matte enamel color that has been previously approved as an appropriate color for Tier 11 facilities at other sites in Albemarle County. Network Objectives Verizon recently secured a license from the Federal Communications Commission to provide Personal Communications Services within a new market that includes the County of Albemarle, City of Charlottesville and other surrounding counties. These services range from phones with voice, data, text, video and GPS capabilities, to wireless broadband solutions for personal and business computer systems. Verizon does not currently offer any service options locally, providing limited services within this market only to existing customers from other areas through roaming agreements with another wireless carrier. There had been no opportunities for Verizon to offer the full range of services until the FCC license was obtained. Verizon has identified several sites throughout the market that will be integral to establishing this service. Once all of the proposed sites are "on-air", Verizon will be able to provide potentially seamless in- building, in -car and on- street coverage throughout the market. By providing coverage within this market, it is Verizon's objective to ensure that the full range of services will be available to existing customers, while also allowing an additional, competitive option for access to wireless services by future customers. The specific facility proposed with this application will establish in- building coverage for the nearby residential units located and it will support in -car coverage for customers traveling on U.S. 29 South, by connecting its service with the other antenna sites that will be installed to the north and south between Covesville and the City of Charlottesville. Verizon Wireless PWSF Page 1 Thackers Lane (Mawyer) Character of the Area The Property is zoned Rural Areas (RA) and Entrance Corridor (EC) overlay district. All of the surrounding properties are zoned Rural Areas. However, the proposed PWSF will not substantially impact the rural character of the surrounding area due to the extensive amount of backdrop that is provided by the wooded slope to the north of the facility. The proposed PWSF will be located approximately 820 feet east of the right -of -way for U.S. 29 in a wooded area below the ridgeline of Cook Mountain. The site of this facility is heavily wooded on a slope that continues upward and to the east. Access to the facility will be provided from the eastern side of U.S 29 by way of Thackers Lane, then over a shared gravel road that continues to an area where there are two existing PWSFs (Alltel and nTelos) near the proposed Verizon site. The nearest off -site dwelling unit is located approximately 700 feet west of the proposed PWSF site. Although a portion of the Property is located in the Mountain Overlay District, the site of this proposed PWSF itself is not. Furthermore. none of the resources defined as avoidance areas in Section 3.1 of the zoning ordinance are within close proximity to the proposed PWSF site. Compliance with Section 5.1.40 of the Zoning Ordinance: The County's specific design criteria for Tier I1 Facilities, set forth in Section 5.1.40(d), are addressed as follows: 5.1.40(d)(1) - The facility shall comply with subsection 5.1.40(b) and subsections 5.1.40(c)(2) through (9). Subsection 5.1.40(b) (1 -5) The proposed PWSF will be in compliance with the setback regulations and all other area and bulk regulations and minimum yard requirements are being met with this request. Verizon has selected a location for the proposed monopole that exceeds the minimum required tower setback distance, which is equal to 100% of the structure's height from all parcel lines shared with adjoining lots. Furthermore, there are no public road rights -of -way within a distance equal to the monopole's height. The attached site drawings, antenna and equipment specifications are being provided to demonstrate that the PWSF regulations and the relevant site plan requirements, set forth in Section 32 of the zoning ordinance, will also be met with this application. Subsection 5.1.40(c)(2) The proposed monopole does not require the installation of guy wires, nor will it be fitted with any whip antennas without any further County approvals. The proposed grounding rod complies with the County's size requirements. The facility will have only one outdoor light fixture attached to the proposed shelter and that fixture will only be used by Verizon's technical operations staff during times when maintenance of the site is necessary. Verizon is currently in the process of securing a design for a retrofit shield for the original light or a replacement light fixture to ensure that the facility will be in full compliance with Section 4.17 of the zoning ordinance. Verizon requests approval to enclose the shelter within a chain link security fence. Subsection 5.1.40(c)(3) The proposed antenna configuration will consist of one sector with three panel antennas (Anphenol Antel Model # BXA- 185085/12) that measure 72.44" x 6.06" x 4.13 ", giving each antenna an area of approximately 439 square inches. These antennas will be installed using "pipe- mounts" that will allow Verizon Wireless PWSF Page 2 Thackers Lane (Mawyer) for any required amount of down - tilting without exceeding the County's requirements for flush - mounts (12- inches maximum between the face of the monopole and the face of the antenna). All antennas will be painted the same color as the monopole. Subsection 5.1.40(c)(4 and 5) : Installation of the proposed PWSF and its extension from the end of the existing road will require the removal of nine trees. However, these trees do not appear to be important in screening the existing PWSFs and there will continue to be an ample amount of backdrop remaining on the incline behind all three monopoles. Additionally, as currently demonstrated with the existing facilities, none of the ground equipment will be visible from anywhere off of the Parcel.. Verizon has already contracted Van Yahres Tree Company to provide a tree conservation plan that will be prepared by a certified arborist. In order to ensure that there is no significant impact to any of the trees that are to remain, the conservation plan will be completed prior to the submittal of a building permit for this facility. Recommendations of the tree conservation plan will then be integrated into the construction process and followed on all portions of the Property that will be affected by the construction of Verizon's facility. Subsection 5.1.40(c)(6) Should use of the antenna site in this location become discontinued at anytime in the future, Verizon and /or its assignee(s) will be required to remove the facility within 90 days. Subsection 5.1.40(c)(7) Verizon shall submit an annual report updating the user status and equipment inventory of the facility in the required time period. Subsection 5.1.40(c)(8) No 2:1 or greater slopes will result from the construction of this facility. Subsection 5.1.40(c)(9) Because the proposed facility will be located in remote area, Verizon proposes the installation of a chain link security fence instead of a screening fence. Verizon's fence will not surround the full extent of the lease area - only the ground equipment shelter, tower and surrounding area as needed to carry out service and maintenance activities. Because the facility site is screened by existing vegetation on all sides and not visible from any adjacent residences, The proposed fence should not be detrimental to the character of the area or the general welfare, safety and health of the surrounding properties and their residents. Section 5.1.40(d)(2) - The proposed PWSF will be located in a heavily wooded area, and will only require removal of nine trees and underbrush, most of which are in the path f the access road extension and do not contribute significantly in providing screening or backdrop to the proposed site. The remaining wooded area around the site will be more than adequate to screen the facilities and provide a backdrop to the proposed tower. Section 5.1.40(d)(3) - Although a portion of the Parcel is in the Mountain Overlay District, this site is well below the ridgeline and the monopole will be afforded an extensive amount of backdrop. Section 5.1.40(d)(4) - Verizon's facility will only be the third PWSF on the Parcel. Verizon Wireless PWSF Page 3 Thackers Lane (Mawyer) Section 5.1.40(d)(5) - The monopole will have a base diameter that is no greater than 30 inches and a top diameter that is no more than 18 inches. Section 5.1.40(d)(6) - Due to the amount backdrop provided by the slope on the north side of the proposed facility, Verizon is requesting permission to install a monopole that will be 10 feet higher than the reference tree. This reference tree has been identified as a 36" caliper Yellow Poplar tree with a dripline that is approximately 20 feet away from the from the monopole location. Because of the backdrop on the incline to the east, Verizon anticipates that there will not be any material difference in adverse impacts to resources identified in the county's open space plan caused by a monopole at the proposed height, rather than seven feet taller than the reference tree. Section 5.1.40(d)(7) - The monopole and all antennas will be painted Sherwin Williams Java Brown #6090. This is a color that has been applied to previously approved PWSF monopoles. The prefabricated shelter that will be installed at the facility has siding that is a natural brown color and an aggregate stone finish. Section 5.1.40(d)(8) - All coaxial cables and service lines running vertically from the transmitting equipment to the antennas will be located inside the monopole. Section 5.1.40(d)(9 -13) - Verizon has reviewed and understands all of the remaining criteria for Tier 11 Personal Wireless Service Facilities and will provide an } additional information or assistance to ensure that these standards are met. Conclusion: Verizon Wireless is confident that the proposed Personal Wireless Service Facility meets the design criteria for approval of a Tier 11 facility and does not conflict with the goals and objectives of the Comprehensive Plan. The approval of this PWSF application will contribute to the deployment of a highly reliable personal communications system in this new market, providing Albemarle County residents and travelers on U.S. 29 an additional option for high quality personal wireless services Sincerely, Ste hen Waller, AICP Site Development Consultant Verizon Wireless, Charlottesville Market Verizon Wireless PWSF Page 4 Thackers Lane (Mawyer) SITE PHOTOS Clo. _ ip \ ie of the proposed monopole locafTon Viexi toward into the east of trees situated uphill from the site Ok r• • .+A ..,3 •rpm ! y 77F •a ' , t • i . f t fl < Viex to %ard the southwest of existing Alltel PVA- SF VieN\ t..... and the southeast ofthe existing nTelos`rkVSl g` 1 t i l 'F 5 t y3w9 5 Vie-vv toNard the south of the eXisting gravel access Vlex\ from the si,_ -_.) the east of the proposed c\tellslon of eme access road r a; ' > .:. ti e,,.:; 'W •" v} b3ar,'•W1'yn .: 1:', .`R':i'3.'z<,N" Vlex\ from the si,_ -_.) the east of the proposed c\tellslon of eme access road Vie\\ toN\ ard N\ est of the access road as it enters the - %ooded area VieNN to the cast from the gravel access road toN and Thackers Lane and I .S. 29 74 - - N 74 - - N ANTENNA SPECIFICATIONS Mechanical specifications B"A 85085/12CF 4°Length 1840 mm 72.44 in Width 154 mm 6.06 in When ordering, replace with Depth 105 mm 4.13 in 4l Weight 5.897 kg 13 Ibs Wind Area Fore /Aft 0.283 m 3.05 ftSide0.195 m2 2.1 ft` Rated Wind Velocity (Safety factor 2 0) 237 km/hr >148 mph Wind load @ 100 mph 061 km /hr) Fore /Aft 460 N 103.4 IbsSide372N83.5 lbs Antenna consisting of aluminum alloy with brassfeedlinescoveredbyaUVsafefiberglassradome. Mounting & Downtilting: Wall mounted or pole tower mount with mountingbrackets. Mounting bracket kit #26799997 Downtilt bracket kit #26799999 The downtilt bracket kit includes the mountingbracketkit. Electrical specifications Frequency Range 1850 -1990 MHz i Polarization Isolation Between Ports Gain 2) Power Rating Half Power Angle H -Plane E -Plane l Electrical Downtilt y Null Fill Lightning Protection 30 dB 18 dBi 250 W 85° 5° 4° 5% Direct Ground Patented Dipole Design: U.S. Patent No. 5,597,324 B2 Typical Values zi Power Rating limited by connector onlyNEindicatesanelongatedNConnector. E-DIN indicates an elongated DIN Connector.a1 The antenna weight listed above does not include thebracketweight. improvements to mechanical and /or electrical performance of theantennamaybemadewithoutnotice. Radiation - pattern' 100 -90 -80 120 -70 60 130 50 140 150 160 1;0 180 1_10 160 15 140 130 0 0 0 110 100 00 " 10 Horizontal 20 16 zo 110 - 100 - 40 - 80 7n so 3o sa 140 40 150 30 6 0 170 10 180 35 0170 0 60 zo 0 30 40 40 130 50 1.0 60 0 100 g0 80 70 Vertical Radiation patterns for all antennas are measured with the antenna mounted on a fiberglass pole. Mounting on a metal pole will typically improve the Front -to- Back Ratio. CF Denotes a Center -Fed Connector. N/ H Watercut brass feedline assembly for consistent performance. Unique feedline design eliminates the need for conventional solder joints inthesignalpath. A non - collinear system with access to every radiating element for broad bandwidth and superior performance. Air as insulation for virtually no internalsignalloss. This Ampheno/ Ante/ antenna is under a five -year limited warranty for repair orreplacement. Antenna available with center -fed connector only. cifilta1 unve Kockford, IL 61109 Toll - Fre888) 417 -9562 Tel. (815) 399 -0001Fax. (815) 399 -0156 Email: antel @antelinc.com www.antelinc.com e ( Impedance connector type F {;.jv( f;, .;'rti s' µ.An Na yi'L"'F Slant t 45° Watercut brass feedline assembly for consistent performance. Unique feedline design eliminates the need for conventional solder joints inthesignalpath. A non - collinear system with access to every radiating element for broad bandwidth and superior performance. Air as insulation for virtually no internalsignalloss. This Ampheno/ Ante/ antenna is under a five -year limited warranty for repair orreplacement. Antenna available with center -fed connector only. cifilta1 unve Kockford, IL 61109 Toll - Fre888) 417 -9562 Tel. (815) 399 -0001Fax. (815) 399 -0156 Email: antel @antelinc.com www.antelinc.com e ( Impedance 5052 s> Connector NE, E -DIN ii VSWR 51.4:1 Slant t 45° Fbe Ast;tara Te:hnvtary (cmpdn Revision Dale: 12.4'06 LIGHTING SPECIFICATIONS f 'A L® /!TO/Y/ L/L7/®/' Catalog Number Notes T FEATURES & SPECIFICATIONS INTENDED USE For entrances, loading docks, walkways and vehicle ramps CONSTRUCTION Rear housing is rugged, corrosion - resistant, die -cast aluminum. Coriosmn- resistant ex- ternal hardware includes slotted hex -head and tamperproof fasteners FINISH Dark Bronze (DDB) corrosion resistant polyester powder OPTICAL SYSTEM Reflector is finished in white thermoset polyester powder, electrostatically applied. Front housing and refractor are one-piece, i injection-molded, UV- stafiiaed polycarbonate Standard finish on opaque portion of front rover and back housing is dark bronze poly- ester enamel Refractor is sealed and gasketed to inhibit the entrance of outside con- taminants. ELECTRICAL SYSTEM 70 15OW is high- reactance, high power factor Enraged- and -potted solid - state ignitor~ 175W is constant- wattage autotransformer Ballast is copper -wound and 100 factory - tested. Meets ANSI standards and is UL listed Electrical components are mounted on back housing (For 50 hertz availability, consult factory) Porcelain, horizontally- onented, medmrn -base (150W) or ntoqul -base (175W) socket with copper alloy, nickel- plated screw shell and center contact UL listed hnedmm base 660W, 51 mogul base 1500W, 60OV1 Both are 4KV pulse riled, INSTALLATION Top 3/4' threaded wiring access Back access through removabir 3/4" knockout. Feed - thru wiring can be achieved by using a condulet tee. Mount on any flat, vertical surface LISTING UL listed suitable for wet locations UL Listed to US and Canadian safety standards (see Options). NOM Certified (see Opnonsl IP64 rated in accordance with EC Standard 529, NOTE: Not recommended for use in car wash interior applications ORDERING INFORMATION Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog numbers (shipped separately) TWP SF Single fuse (120, 277, 347V) DF Double fuse (208, 240, 48OV) Series Emergency circuit" Wattage /Vol TWP 70M 120 Non -stick protective coating' loom'208' LPI 1501M' a 240' Less Lamp 175M 277 FS Full shield 347 Wireguard SCWA 480 CSA Listed and labeled to comply with Canadian TB' Standards NOM TBV1071 NOTES: 1 Not available 480V. 2 Not available in Canada. 3 Optional multi -tap ballast (120, 208, 240, 277V) In canada 120, 277, 347V, ships as 120/347. 4 Not available with multi -tap ballast. 5 Lamp not included. 6 Quartz lamp wattage not to exceed ballast wattage rating. 7 Black finish on housing only 8 May be ordered with SCWA. 9 ORSTD is available for select wattages; consult factory. 10 Optional 5 -tap ballast (120,208,40,2277,480V). 11 Only available with 175M. 12 Not available with TBV. Wall Packs Specifications Height: 15- 7/16" (39.2crn) Width: 16 -1/8" Olcm) Depth: 7 -3/4" (193cm) Weight: 16 Ibs (7 kg) METAL HALIDE 70W, 100W, 150W, 175W 8' to 15' Mounting Example: TWP 175M 120 LPI Options Shipped installed in fixture SF Single fuse (120, 277, 347V) DF Double fuse (208, 240, 48OV) EC Emergency circuit" ORS Quartz restrike system"' CR Enhanced corrosion - resistance CRT Non -stick protective coating' PE Photoelectric cell, button type" LPI Lamp included L/LP Less Lamp LS Lamp support (mogul socket only) FS Full shield WIG Wireguard SCWA Super CWA Pulse Start Ballast CSA Listed and labeled to comply with Canadian Standards NOM NOM Certified (Consult factory) Architectural color o gt ionall DBL Black DMB Medium brpnze DWH White DNA Natural aluminum DSS Sandstone Accessories Order as separate catalog number RK1 PEB1 Photoelectric control kit (120V) RKt Fil l CSA Photoelectric control kit (120V only) RK1 Ill Photoelectric control kit (208,240,277V) RK1 PEB3 CSA Photoelectric control kit (347V) RK1 TWPFA FS Field installable fall shield for cutoff Outdoor and Special Environments Sheet #: TWPM SE HID -240 TWP Metal Halide Wall Packs Coefficient of Utilization Initial Footcandles TWP 70M Test Report no. 97021601 Coefficients of utilization 2 L N m J 0 1 0 c m v C 1 r l J O 1 2 31 4 5 6 Distance in units of mounting height 70W, metal halide lamp, horizontal lamp ori- entation, 10' mounting height, 5,200 rated lumens. Total fixture efficiency: 50.7% ELECTRICAL CHARACTERISTICS TWP 175M Test Report no. 94121102 Coefficients of utilization 2 Lm 1 _ JL 0 I 0 1 2 -- 0 1 2 - 5 — -- 2 U N 4 1 __ 0 1 2 3 4 5 6 Distance in units of mounting height 175W, metal halide lamp, horizontal lamp orientation, 12' mounting height, 14,000 rated lumens. Total fixture efficiency: 53% fA LMAAC IIA LIMA r`M9(w Lithonia Lighting An 'I-McuftBrands Company Outdoor Lighting One Lithonia Way, Conyers, GA30012 -3957 Phone 770-922-9000 Fax. 770-918-1209Sheet #: TWPM_SE J1989 Acuity Lighting Group, Inc ,Rev. 4/06 www.lithoma com Line current Primary Primary amps)dropout Input Power Regulation Wattage /ballast voltage start /operating voltage watts factor ( %) Line V = Lamp lumens 120 1.20/1.15 75 Mounting Height Correction Factor 100 XHP 208 0.70/0.60 130 130 90+ ±5% = ±10%Multiply the to level by the correction factor) 240 0.61,150 10 12' 277 0.55/0.45 165 10ft. =1.44 347 0.46/0.38 235 15 ft. - .44 15 ft. - 64 120 1.10/1.80 70 20 ft = .25 20 ft. ` .36 175CWA 208 64/1.10 115 25 ft = .16 25 ft.= Peak -lead 240 5500 132 210 90+ ±10% 23 Autotransformer 277 48/.78 150 480 12/.45 264 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause Existing Mounting Heightdifferencesbetweenlaboratorydataandactualfieldmeasurements. Dimensions and specifications on this sheet are C ) = Correction Factor based on the most current available data and are subject to change without notice.New Mounting Height fA LMAAC IIA LIMA r`M9(w Lithonia Lighting An 'I-McuftBrands Company Outdoor Lighting One Lithonia Way, Conyers, GA30012 -3957 Phone 770-922-9000 Fax. 770-918-1209Sheet #: TWPM_SE J1989 Acuity Lighting Group, Inc ,Rev. 4/06 www.lithoma com