Loading...
HomeMy WebLinkAboutSDP200900031 Review Comments 2009-03-24Page 1 of 1 Amy Pflaum From: Amy Pflaum Sent: Tuesday, March 24, 2009 3:50 PM To:rburkholder @balzer.cc' Subject: Collins Medical Center (Westfield) Ray, I was able get a determination from the Chief of Current Development on the validity of the previously approved Critical Slopes Waiver on this site. The Critical Slopes Waiver, approved with SP200500033 by the Planning Commission on March 14, 2006, will remain valid so long as the Final Site Plan which was approved on this site does. The Final Site Plan (SDP200500136) was approved April 18, 2007, and is valid for 5 years from that date. It is understood that the development you are proposing is different than the previously approved site plan, however, if the disturbance to the critical slopes remains in general accord with the previously proposed disturbance, then the waiver remains valid. This Critical Slopes Waiver was approved with the following condition: 1. Peak rate and velocity of runoff shall be controlled to pre - development levels. I would suggest that you print this email and submit it along with your preliminary site plan so that it is clear this determination has been made. Please let me know if I can answer any further questions. Thank you, Amy D. Pflaum Senior Civil Engineer Albemarle County Department of Community Development 434) 296 -5832 x3069 apflaum @albemarle_org 4/22/2009 6 110® —iiaT. 7RGiNIP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 DATE: May 12 2009 Ray Burkholder (Blazer and Associates) 1561 Commerce Road Verona, VA, 24482. RE: SDP - 2009 -00031 Collins Medical Center Preliminary Site Plan. Dear Sir, The Site Review Committee has reviewed the development proposal referenced above. Preliminary comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Division of Zoning & Current Development (Planner) Albemarle County Division of Zoning & Current Development (Engineer) Albemarle County Division of Planning (ARB Planner) Albemarle County Division of Planning (Development Area Planner) Albemarle County Division of Inspections (Building Official) Virginia Department of Transportation (VDOT). Albemarle County Service Authority (ACSA). Albemarle County Geographic and Data Services (GDS) Albemarle County Fire and Rescue Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that could affect approval of the proposed project. Please make the revisions that have been identified as necessary for preliminary approval by the Site Review Committee. If you choose not to make the requested revisions, please submit in writing justification for not incorporating such revisions. Submit eight (8) full size copies and one (1) 1 l " x 17" copy to the Department of Community Development including responses to each of the attached comments of the Site Review Committee by Monday, June 1 2009. Failure to submit this information by this date will result in suspension of the review schedule. Review will resume when revisions are submitted along with a reinstatement fee of $65. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, II 40 ( l Gerald Gatobu, Principal Planner County of Albemarle Department of Community Development Current Development 401 McIntire Road Charlottesville, VA 22902 -4596 Phone: (434)296 -5832 Ext 3385 Fax: (434)972 -4126 o ALrip RGtN County of Albemarle Department of Community Development Memorandum To:Ray Burkholder From:Gerald Gatobu, Principal Planner Division: Zoning and Current Development Date:May 15, 2009 Subject: SDP2009 -00031 Collins Medical Center Preliminary Site Plan The County of Albemarle Division of Zoning and Current Development will grant or recommend approval of the preliminary site plan referred to above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 32.5.6 The preliminary site plan shall contain the following information: a. The name of the development; Include the site plan number SDP2009 -00031 to the site plan for current and future reference. Please consider having a cover sheet with pertinent site information. Owner, zoning, tax map and parcel number and present use of adjacent parcels; Please add the zoning of adjacent properties b. Written schedules or data as necessary to demonstrate that the site can accommodate the proposed use, including: Maximum number of employees; Include the number of employees to be working at the dental office. Maximum amount of impervious cover on the site; please add the amount of impervious cover on the site plan in square feet. If a landscape plan is required, maximum amount of paved parking and vehicular circulation areas Clearly delineate the amount of paved parking and vehicular circulation areas. The amount of paved parking and vehicular circulation areas will be used for landscape calculations] e. Existing landscape features as described in section 32.7.9.4.c. provide an existing landscape features sheet per section 32.7.9.4.c. of the zoning. ordinance. n. Location and dimensions of all existing and proposed improvements including: Outdoor lighting: Proposed outdoor lighting should meet the outdoor lighting regulations found in section 4.17 of the Zoning Ordinance. A lighting plan that meets required outdoor lighting regulations must be submitted at final site plan stage (if outdoor lighting is proposed) Signs: please remove the proposed sign location shown on the site plan. Sign location shall be approved with/during sign permit application. Signature Panel: Please add the attached signature /approval panel to the site plan. 1 pF ALA Veepwrovam IkGIN County of Albemarle Department of Community Development Memorandum To:Gerald Gatobu, Principal Planner From: John P. Diez, Engineering Review Division: Current Development Date:May 4, 2009 Subject: SDP200900031 Collins Medical Center - Preliminary Site Plan The preliminary site plan for Collins Medical Center, submitted on April 22, 2009, has been reviewed. Current Development Engineering has the following comments: Preliminary Site Plan Comments 1. Please correct the date on the plan's title block. 2. Please provide a modified simple method spreadsheet to show the required removal rate for the drainage area. 3. The angle of the dumpster pad creates an awkward backup situation. It is recommended that the dumpster pad be rotated 90 degrees and centered within the 24' aisle width. [18- 32.7.2] 4. Please show site distance lines at the entrance onto Westfield Road, easements may be required. Final Site Plan Comments The following comments are not required to be addressed at this time. They are provided for informational purposes only. 5. Depending on the depth and size of the proposed detention pipe, an easement may be required on TMP 61W-02-0B-5+. Please see Albemarle County Design Standards Manual Section 6 for required easement widths. 6. The stormwater management plan must meet MS -19 of the Virginia Erosion and Sediment Control Handbook. Please provide information showing that the pipe and channel downstream is adequate. Serv Auth/ r ty TO: Gerald Gatobu FROM: Gary Whelan, Civil Engineer DATE: May 11, 2009 RE: Site Plan Technical Review for: Collins Medical Center - Preliminary SDP200900031 TM 61W-2B-1A The below checked items apply to this site. X 1. This site plan is within the Authority's jurisdictional area for: X A. Water and sewer B. Water only C. Water only to existing structure D. Limited service X 2. An 8 inch water line is located approximately 35' distant. X 3. Fire flow from, nearest public hydrant, located 20' distant from this site plan, is 2503 Gpm + at 20 psi residual. X 4. A 10 inch sewer line is located approximately 10' distant. 5. An Industrial Waste Ordinance survey form must be completed. X 6. No improvements or obstructions shall be placed within existing or future easements. 7.and plans are currently under review. 8.and plans have been received and approved. X 9. No plans are required. 10. Final and plans are required for our review and approval prior to granting tentative approval. 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. 13. City of Charlottesville approval for sewer. Comments: Backflow prevention is required. Provide plumbing fixture count to size the meter The site plan does not show or incorrectly shows: meter locations water line size waterline locations sewer line size sewer line locations expected wastewater flows easements expected water demands 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthoriy.org Application #:SDP200900031 Short Review Comnv'nts Project Name:rCollins Medical Center - Prelim I Preliminary – Non - residential Date Completed:05/11/2009 Reviewer:Andrew Slack E911 Review Status:No Objection Reviews Comments: NO OBJECTION. Date Completed:05/05/2009 Reviewer:Brent Nelson ARB Review Status:Pending Reviews Comments: An ARB application has been received for this proposal. It is scheduled for review at the June 1, 2009 • meeting. Date Completed:05/04/2009 Reviewer:James Barber Fire Rescue Review Status:No Objection Reviews Comments: Verify adequate fire flow is available. Must comply with the Virgnia Statewide Fire Prevention Code. Approval is subject to field inspection and verification. Date Completed:05/04/2009 Reviewer:John Paul Diez Engineer Z &CD Review Status:Requested Changes Reviews Comments: Previously approved CSW Date Completed:05/04/2009 Reviewer:John Paul Diez Engineer Z &CD Review Status:No Objection Reviews Comments: CSW previously approved w/ SP200500033, need to verify that disturbance is the same. Date Completed:05/07/2009 Reviewer:Judith Wiegand Planning Review Status:Requested Changes Reviews Comments: [tall has reviewed this preliminary site plan for conformity with the Comprehensive Plan, including the' Neighborhood Model. Staff recommends that the building be moved close to the street and the parking be placed behind the building in order to be in compliance with the Neighborhood Model principle recommending relegated parking. If the building were moved closer to the street, it would also form an even line of building fronts along the street with the buildings to the east and west. Staff is also concerned that, with the addition of the entrance to this property, there will be three entrances very close to each other. Page: 1.00 County of Albemarle Printed On: Monday, May 18, 2009 7r County of Albemarle Department of Community Development Memorandum To:Gerald Gatobu, Principal Planner From: John P. Diez, Engineering Review Division: Current Development Date:May 4, 2009 Rev.1 July 16, 2009 Subject: SDP200900031 Collins Medical Center - Preliminary Site Plan The preliminary site plan for Collins Medical Center, submitted on April 22, 2009, has been reviewed. Current Development Engineering has the following comments: Preliminary Site Plan Comments 3. The angle of the dumpster pad creates an awkward backup situation. It is recommended that the dumpster pad be rotated 90 degrees and centered within the 24' aisle width. [ 18- 32.7.2] Revd ) Duntpster pad has been removed. 4. Please show site distance lines at the entrance onto Westfield Road, easements may be required. Revd ) Comments have not been addressed per VDOT standards in the Design Standards Manual . Final Site Plan Comments The following comments are not required to be addressed at this time. They are provided for informational purposes only. 5. Depending on the depth and size of the proposed detention pipe, an easement may be required on TMP 61W-02-0B-5+. Please see Albemarle County Design Standards Manual Section 6 for required easement widths. 6. The stormwater management plan must meet MS -19 of the Virginia Erosion and Sediment Control Handbook. Please provide information showing that the pipe and channel downstream is adequate. COMMONWEALTH. oof VIRGM DEPARTMENT OF TRANSPORTATION CHARLOTTESVILLE RESIDENCY OFFICE 701 VDOT WAY CHARLOTTESVILLE, VA 22911 DAVID S. EKERN, P.E. COMMISSIONER May 20` 2009 Mr. Glenn Brooks Department of Engineering and Development 401 McIntire Rd. Charlottesville, VA 22902 Subject: Site Review Meeting Comments May 21 , 2009 site review meeting Dear Mr. Brooks: Below are VDOT's comments on the Site Plans for the May 21 2009 Site Review Committee Meeting: SDP - 2006 - 00041 Briarwood Phase 1A - 1, 1B - 1, 8 (Elizabeth Marotta) 1. Engineering comments were provided by VDOT on 4 -23 -09 for the additional phase of the project. SDP - 2009 - 00030 Forest Lakes Office Park - Major (Summer Frederick) 1. No comments SDP - 2009 - 00031 Collins Medical Center - Preliminary (Gerald Gatobu) 1. Final plans need to show the proposed entrance profile. 2. Final plan needs to show details for CG -6, CG -11, and CG -12B and detectable warning. 3. A Land Use Permit will be required for construction within the public road right of way. SDP - 2009 -00033 University Village Retirement Community(Phase I) Summer Frederick 1. The proposed connection to Route 29 needs to be a minimum of 510 feet from the existing intersection or line up with the intersection at the signal. WE KEEP VIRGINIA MOVING 2. This site plan exceeds the threshold to require a Chapter 527 Traffic Impact Analysis. 3. The proposed road must provide a connection to the existing Boulders Road to meet the connectivity requirements of SSAR's, 24VAC 30 -92. Without the connection the road may not be eligible for acceptance into the State Secondary System of Highways. 4. The CG -12 detail needs to be updated and show the proper detectable warning. 5. The proposed Functional Classification needs to be indicated on the plan. 6. If the connection is made to Boulders Road, additional traffic will need to be shown to properly determine the design speed and pavement structural section of the road. 7. Provide the horizontal alignment data on the roads. 8. Street design data on sheet R -4 lists University Village Road but the plans show University Village Dr. Is this the same road? 9. The sight distance on University Village Dr. / Rd. need to be based on the correct design speed on the road. 10. Pavement design on University Village Dr. needs to be designed in accordance with the AASHTO method if this is designed as a collector road. 11. Storm sewer pipes need to be as perpendicular as possible to the centerline of the road and cannot exceed 45 degrees. 12. Street Trees on University Village Dr. need to be located outside of the clear zone of the road if this road is to be classified as a collector. SDP - 2009 -00034 Martha Jefferson Outpatient Care Center (Proffit) -Major (Gerald Gatobu) 1. It appears that the parking and detention facility for this site is in conflict with a previous plan for the widening of Proffit Road and the construction of a roundabout at this intersection. The road plan indicates that there has been a dedication of right of way for the road widening and intersection improvement. Please request the applicants provide a written description of revisions with re- submissions. If you have any questions or comments, please contact me prior to sharing these comments with the applicants. Sincerely, Joel DeNunzio, P.E. Staff Engineer VDOT Charlottesville Residency 434 - 293 -0011 WE KEEP VIRGINIA MOVING