Loading...
HomeMy WebLinkAboutSDP200900091 Approval - County 2009-12-171 County of Albemarle Department of Community Development Memorandum To:Scott Collins From:Gerald Gatobu, Principal Planner Division: Zoning and Current Development Date:December 17, 2009 Subject: SDP2009 -00091 Arden Place Final Site Plan The County of Albemarle Division of Zoning and Current Development will grant or recommend approval of the final site plan referred to above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] Proposed wooded area is shown on several sheets and is labeled/shown in the open space (dedicated area) 0.977 acres] on sheet LL3. 0 L''Please revise the development density calculation 15 du /acre x (0.1 +015 +1) = 18.75 the current calculation is incorrect. Setbacks from any street right of way or single family residential or agricultural district shall be set back in addition to minimum yard requirements, a distance of not less than two (2) feet for each one (1) foot of height in excess of thirty -five (35) feet. Please delineate on the site plan the setbacks from all single family residential districts in relation to the proposed 65' buildings. 4.16.2.1 ] Substitution of equipment, [Clubhouse, pool tot lot and playing field] Substitutions of equipment or facilities will be approved by the Director of Planning and Community Development, provided they offer a recreational amenity equivalent to the facilities listed, and are appropriate to the needs of the occupants. Subdivision Plat approval is e required before final site plan approval is granted. The subdivision plat will dedicate areas to public use and subdivide the R15 residential portion of the property from the Cl Commercial property. Accompanying deeds must be submitted for review and approval. Landscape Plan 15% tree canopy is required for this development and not 10 %. Tree Canopy required is calculated per the gross fesidential density. Based on the gross residential density for this project a 212/11.35 = 18.67 a 15% and not 10% tree canopy is required. Canopy for the site can only be attributed to trees that are within the project boundary. Off site tree do not count towards canopy calculations. Wax Myrtle has a 10 year canopy coverage of 44 and not 47 Wintergreen Barberry has a 10 year canopy coverage of 14 and not 16 w" Pampass Grass is not on the plant list r- Pink Muhly is not on the plant list e Snow Mound Spirea is not on the plant list 1 6. Safety slabs are now designated for any storm structure over 12 feet. 7. Drainage structures have been added at the bottom of the Carmike Connection near the intersection of the existing parking lot. In addition, the existing drainage inlets have been shown on the plan as well. There is also positive drainage from the Carmike connection to the (2) inlets in the parking lot. 8. Guardrail is now shown just northeast of building 5 as suggested. 9. A waiver request is included with this submittal for the travelway slope in excess of 10 %. 10. Matchline on S -3 has been adjusted to improve the readability of the Carmike connection. Bridge details are provided on S -7. Additional information on the crossing, including hydraulic computations, are now provided. Please let me know if you have any questions or require any additional information. Si erely, Scott Collins, PE