HomeMy WebLinkAboutSDP200900017 Review Comments 2009-04-13o1 ®
jRGIN
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
DATE: April 13, 2009
Brian P Smith PE
105 West High Street
Charlottesville, VA, 22902.
RE: SDP - 2009 -00017 Humagen Fertility Diagnostic Minor Amendment
Dear Sir,
The Site Review Committee has reviewed the development proposal referenced above. Preliminary
comments for the following divisions of the Department of Community Development and other agencies,
as applicable, are attached:
Albemarle County Division of Zoning & Current Development (Planner)
Albemarle County Division of Zoning & Current Development (Engineer)
Virginia Department of Transportation (VDOT). (Pending)
Albemarle County Service Authority (ACSA).
Albemarle County Geographic and Data Services (GDS)
Albemarle County Fire and Rescue
Comments reflect information available at the time the development proposal was reviewed, and should
not be considered final. However, the Site Review Committee has attempted to identify all issues that
could affect approval of the proposed project.
Please make the revisions that have been identified as necessary for preliminary approval by the Site
Review Committee. If you choose not to make the requested revisions, please submit in writing
justification for not incorporating such revisions. Submit eight (8) full size copies and one (1) 11" x 17"
copy to the Department of Community Development including responses to each of the attached
comments of the Site Review Committee by Monday April 27th 2009. Failure to submit this information
by this date will result in suspension of the review schedule. Review will resume when revisions are
submitted along with a reinstatement fee of $65. Please contact me at your earliest convenience if you
have questions or require additional information.
Since -1. ,
rald Gatobu, Principal Planner
County of Albemarle
Department of Community Development
Current Development
401 McIntire Road
Charlottesville, VA 22902 -4596
Phone: (434)296 -5832 Ext 3385
Fax: (434)972 -4126
5
AL &
in fi8
t 'IRGi V"
County of Albemarle
Department of Community Development
Memorandum
To:Brian P Smith
From:Gerald Gatobu, Principal Planner
Division: Zoning and Current Development
Date:April 15, 2009
Subject: SDP2009 -00017 Humagen Fertility Diagnostics Inc Minor
The County of Albemarle Division of Zoning and Current Development will grant or recommend
approval of the site plan referred to above once the following comments have been addressed:
Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning
Ordinances unless otherwise specified.]
32.5.6 The preliminary site plan shall contain the following information:
a. The name of the development;
County: Add to the site plan the County where the property is located.
Minimum setback lines, Add the 10' parking setback line to sheet 3 of 6. Please make
sure that the parking lot does not encroach into the 10' parking setback.
b. Written schedules or data as necessary to demonstrate that the site can accommodate the
proposed use, including:
Maximum amount of impervious cover on the site; Add the maximum amount of
impervious cover to the site.
If a landscape plan is required, maximum amount of paved parking and vehicular
circulation areas; Please add the amount of paved parking and vehicular circulation
areas to the site plan. This will be used to determine the required amount of interior
landscaping.
LIGHTING PLAN REVIEW CHECKLIST
Lumen level (3000 or more must be full cutoff)
Thank you this has been adequately addressed.
Bulb /lamp location (must be totally within house to be full cutoff)
Thank you this has been adequately addressed.
Luminaire schedule
Catalog # coordinated with cut sheets
Thank you this has been adequately addressed.
Fixture quantity /types coordinated with quantity /types on lighting plan
Thank, you this has been adequately addressed.
Pole height /mounting height (ARB)
NA
Colors /finishes (ARB)
NA
Tilt (must be 0 for full cutoff)
Thank you this has been adequately addressed.
Fixture locations
Location conflicts with trees, utilities, etc.
Thank you this has been adequately addressed.
Coordination with other site plan sheets
Thank you this has been adequately addressed.
Shielding issues (freestanding signs, wall fixtures, etc.)
Photometric plan
Adjacent zoning
Thank you this has been adequately addressed.
Property lines
Thank you this has been adequately addressed.
Excessive spillover
Thank, you this has been adequately addressed.
Excessive lighting levels (ARB)
NA
Maintenance factor = 1.0
Maintenance factor should be 1.0 and not 0.75 Please revise.
Standard lighting notes
On cover sheet. Thank you this has been adequately addressed.
Landscape Plan Checklist
Section 32.7.9.6: STREET TREES
a) Street trees shall be required along existing or proposed public streets in any
development which is subject to site development plan approval in all commercial and
industrial districts and residential development of a density of four (4) dwelling units per
acre or greater. The agent may waiver this requirement in certain cases where site
conditions warrant an alternate solution.
b) Street trees shall be selected from a current list of recommended large shade trees approved
by the agent. Medium shade trees may be substituted, subject to the approval of the agent when
site conditions warrant smaller trees. The agent may approve substitutions of species of large or
medium shade trees.
c) Street trees shall be planted with even spacing in a row adjacent to the public street right -
of -way.
c) One (1) large street tree shall be required for every fifty (50) feet of road frontage, or
portion thereof, if twenty -five (25) feet or more.
c) Where permitted, one (1) medium shade tree shall be required for every forty (40)
feet of road front -age, or portion thereof, if twenty (20) feet or more.
c) The agent may approve minor variations in spacing.
d) In the case of development with units for sale, the trees shall be protected through an open
space or easement arrangement and shall be maintained by a property owner's association.
Comment: Please indicate on the landscape plan the number of street trees
provided for the development.
Section 32.7.9.7: PARKING LOT LANDSCAPING
All development subject to site development plan review shall include the following required
landscaping for parking lots consisting of five (5) spaces or more:
a) Street trees: Street trees shall be planted in accordance with section 32.7.9.6 along the
public street frontage which abuts a parking lot.
a) The trees shall be planted between the street right -of -way and the parking area, within the
parking setback.
a) If required street trees cannot be planted within the parking setback or within ten (10) feet
of the street right -of -way due to sight distance, utility easement or other conflicting requirements,
then the planting strip shall be enlarged to accommodate the trees.
a) If this requirement creates a hardship by causing the relocation of required parking spaces,
then the additional planting area may be counted toward the interior landscaping requirement;
b) Interior landscaping: Exclusive of the requirements of section 32.7.9.7 (a) and (c), an
area equal to five (5) percent of the paved parking and vehicular circulation area shall be
landscaped with trees or shrubs.
b) This shall include one (1) large or medium shade tree per ten (10) parking spaces or
portion thereof, if five (5) spaces or more.
b) Interior landscaping shall be located in reasonably dispersed planting islands or perimeter
areas. Shrub plantings adjacent to a building shall not be counted as interior landscaping;
c) Additional plantings along public streets: When a parking lot is located such that the
parked cars will be visible from a public street, then additional landscaping of low street shrubs
shall be required between the street and the parking lot.
c) Shrubs shall be in a single row planted five (5) feet on center.
c) Alternate methods of landscaping designed to minimize the visual impact of the parking lot
may be approved by the agent.
Comment: Based on the paved parking and circulation area please indicate
on the site plan an area equal to five (5) percent of the paved parking and
vehicular circulation area that is landscaped with trees or shrubs. This
shall include one (1) large or medium shade tree per ten (10) parking
spaces or portion thereof, if five (5) spaces or more.
pr' .a1,yF tr
County of Albemarle
Department of Community Development
Memorandum
To:Gerald Gatobu, Current Development Project Planner
From: Phil Custer, Current Development engineering review
Date:1 April 2009
Subject: Humagen Minor Amendment (SDP -2009- 00017)
The minor amendment for the Humagen Facility has been reviewed. Engineering review for Current
Development can recommend approval to the minor amendment after the following comments have been
addressed:
1. Critical slopes are disturbed with this application and this disturbance requires a waiver. These critical
slopes were created with the construction of site plan SDP -1996 -00030 and are likely not designated
on the county's open space plan. Therefore, the disturbance shown in this plan is eligible to be waived
by the Director of Current Development, unless the application is called up to the Planning
Commission. Before the Director can waive such disturbance, the Zoning Ordinance requires the
approval of an Erosion and Sediment Control Plan beforehand. Approval of an ESC plan will likely be
a condition of Director's granting of the critical slope waiver. The engineering review of the critical
slope waiver will be given in a separate document.
2. The parking lot should be graded in such a manner that no slopes steeper than 5 %, other than in the
transitional area at the entrance from the travelway, exist. This appears to be possible by moving the
468 contour line and still keeping the corner of the lot at 467. (Please see the sketch at the end of this
memo.)
3. The hatched area in the upper parking lot should be a curbed island. [18- 4.12.15.f]
4. Please provide a note on the pipe profile stating that the contractor is to provide a concrete transition
from the end - section to the bottom of the VDOT ditch.
5. VDOT approval is required for the proposed pipe outlet into public ROW.
6. A WPO application and fee are required for the SWM and ESC plan review.
The following are unofficial WPO plan comments that must be addressed with the WPO application prior
to site plan approval.
1. The new drop inlet should be a DI -3A so that the Filterra hydraulics are more likely to work properly
in the field. Spot elevations on the pavement at the throat of the Filterra and curb inlet should be
provided.
2. Please specify the size of the Filterra.
3. An approval letter from Filterra is required.
4. The ESC plan required as a condition of the critical slope waiver must be a full plan including all
applicable items in the design manual checklist.
rael
0,11Re' pag,e'e i -vg—ai
Y.,
1s-
o
C.--1!..:,*-------------
I/ill
4,
4• • . , „ • 4 „,
4'1
11
Ti
X -*),e rl't t)e . 7 .....,„...,,........,„7-- s „„,,,,0 A. r44"/”Atql,j..,,r-t,1 .. ; ,.. .........
ii
t
tilI/apri-'
i .,,,, f li1 $1III11iI '
0...iir
4. * - „ itt,- 4„.,_i * •iffit**--
L
4*li
iittitg i 8.ir 0 • w •
i n
1...„,t
0 0 1 /0,
C' , , Y;;',.
11',
ecir+«
County of Albemarle
Department of Community Development
Memorandum
To:Gerald Gatobu. Current Development planning
From: Phil Custer, Current Development engineering review
Date:1 April 2009
Subject: Humagen critical slope waiver request (SDP- 2009 - 00017)
The critical slope waiver request has been reviewed. The engineering analysis of the request follows:
Description of critical slope area and proposed disturbance:
The critical slope disturbance on parcel 79 -4C is necessary for the construction of an additional 7 space
parking lot. The analysis provided in this report is based on the drawing dated 20 March 2009.
The entire critical slope disturbance occurs within 15ft of the ROW of Hunters Way. This area of critical
slopes is manmade.
Areas Acres
Total site 2.75 acres
Critical slopes 1.04 38% of site
Critical slopes disturbed 0.004 0.42% of critical slopes
Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable
alternative locations:
There are no exemptions for the proposed disturbance.
Compliance with Zoning Ordinance 18 4.2.5.b:
Below is the section of the Zoning Ordinance that specifies instances where the Director of Current
Development may grant a waiver to allow critical slope disturbance. The engineering commentary
regarding the ordinance text is written in bold italics.
Waiver by the agent. In accordance with the procedures stated in section 2.5 of this chapter, the
agent may waive the prohibition of disturbing critical slopes on any parcel not within the Rural
Areas (RA), Monticello Historic District (MHD) or Village Residential (VR) zoning districts in the
following circumstances: (i) the critical slopes were created during the development of the
property pursuant to a site plan approved by the county; or (ii) the critical slopes will be disturbed
to replace an existing structure located on the critical slopes and the extent of the disturbance is
the minimum necessary to replace the existing structure with a new structure whose footprint
does not exceed the footprint of the existing structure. The agent may grant a waiver if he or she
finds that:
The zoning of this parcel is Light Industrial. The critical slopes were created with the construction of
site plan SDP -1996- 00030.)
Albemarle County Community Development
Engineering Review comments
Page 2 of 2
1. The property is not identified in the open space plan as one having any protected resources
and a field inspection has confirmed that there are no significant or critical features on the
property identified for protection in the open space plan;
The planner will determine whether these slopes are protected on the County's Open Space Plan.)
2. There is no reasonable alternative that would eliminate or reduce the disturbance of critical
slopes;
Due to the steep slopes existing on site, the current alignment of the 7 space parking lot is the only
reasonable option to provide those spaces.)
3. The developer or subdivider submitted and obtained approval from the program authority of
an erosion and sediment control plan, regardless of whether the area disturbed is less than ten
thousand (10,000) square feet; and
The applicant has not submitted an application for an Erosion and Sediment Control Plan.
Engineering review recommends that any administrative waiver for critical slope disturbance be given
with a condition that requires approval of an ESC plan.)
4. The developer or subdivider submitted and obtained approval from the county engineer of a
plan that describes how the movement of soil and rock, stormwater runoff, siltation of natural
and man -made bodies of water, the loss of aesthetic resources identified in the open space
element of the comprehensive plan and, in the event of the failure of a treatment works and
subsurface drainfield, a greater travel distance of septic effluent, will be mitigated through
design, construction techniques, revegetation, stormwater management and other best
management practices.
The Water Protection Ordinance Plan will address all concerns regarding siltation of waterbodies,
stormwater runoff and the movement of soil and rock. The existing septic field is located at the
opposite end of the property and disturbance will not encroach upon this area.)
To conclude, it appears that the plan meets all of the standard requirements necessary for granting of an
administrative critical slope waiver with the exception of the site plan having approval for Erosion and
Sediment Control. Engineering review recommends approval of this critical slope waiver on the condition
that the applicant obtains approval of an Erosion and Sediment Control Plan.
Serv Authiority
rta
TO: Gerald Gatobu
FROM: Gary Whelan, Civil Engineer
DATE: April 9, 2009
RE: Site Plan Technical Review for: Humagen Fertility Diagnostics, Inc
SDP200900017
TM 79 -4C
The below checked items apply to this site.
X 1. This site plan is not within the Authority's jurisdictional area for:
X A. Water and sewer
B. Water only
C. Water only to existing structure
D. Limited service
X 2. A 16 inch water line is located approximately 1200 distant.
3. Fire flow from, nearest public hydrant, located distant from this site plan, is
Gpm + at 20 psi residual.
4. An inch sewer line is located approximately distant.
5. An Industrial Waste Ordinance survey form must be completed.
X 6. No improvements or obstructions shall be placed within existing or future
easements.
7.and plans are currently under review.
8.and plans have been received and approved.
X 9. No plans are required.
10. Final and plans are required for our review and approval prior to
granting tentative approval.
11. Final site plan may /may not be signed.
12. RWSA approval for water and /or sewer connections.
13. City of Charlottesville approval for sewer.
Comments: No Comment.
The site plan does not show or incorrectly shows:
meter locations water line size
waterline locations sewer line size
sewer line locations expected wastewater flows
easements expected water demands
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthoriy.org
Application #:SDP200900017 - - Short Review Comnyants,
Project Name:,Humagen Fertility Diagnostics, Inc - (Phase 3) -Minor Minor Amendment
Date Completed:04/08/2009
Reviewer:Andrew Slack E911
Review Status:No Objection
Reviews Comments: NO OBJECTION.
Date Completed:04/06/2009
Reviewer:James Barber Fire Rescue
Review Status:No Objection
Reviews Comments: Must comply with the Virginia Statewide Fire Prevention Code. Approval is subject to field inspection
and verification.
Date Completed:04/06/2009
Reviewer:Jay Schlothauer Inspections
Review Status:No Objection
Reviews Comments: No Objection.
Date Completed:04/10/2009
Reviewer:Margaret Maliszewski ARB
Review Status:No Objection
Reviews Comments: This proposed development is not expected to be visible from the EC. Consequently, ARB review will
not be required.
Date Completed:04/01/2009
Reviewer:Philip Custer Engineer Z &CD
Review Status:No Objection
Reviews Comments:
Page: 1.00 County of Albemarle Printed On: Wednesday, April 15, 2009
t
g54-
County of Albemarle
Department of Community Development
Memorandum
To:Gerald Gatobu, Current Development Project Planner
From: Phil Custer, Current Development engineering review
Date:1 May 2009
Subject: Humagen Minor Amendment (SDP- 2009 - 00017)
The minor amendment for the Humagen Facility has been reviewed. Engineering review for Current
Development can recommend approval to the minor amendment after the following comments have been
addressed:
1. Critical slopes are disturbed with this application and this disturbance requires a waiver. These critical
slopes were created with the construction of site plan SDP -1996 -00030 and are likely not designated
on the county's open space plan. Therefore, the disturbance shown in this plan is eligible to be waived
by the Director of Current Development, unless the application is called up to the Planning
Commission. Before the Director can waive such disturbance, the Zoning Ordinance requires the
approval of an Erosion and Sediment Control Plan beforehand. Approval of an ESC plan will likely be
a condition of Director's granting of the critical slope waiver. The engineering review of the critical
slope waiver will be given in a separate document.
Rev. 1) Approval of the critical slope disturbance will be granted by the Chief of Current
Development with the condition that an ESC plan is submitted and approved.
5. VDOT approval is required for the proposed pipe outlet into public ROW.
Rev. 1) VDOT approval has not, yet been received. Correspondence from VDOT will be forwarded
to the applicant once it is received.
6. A WPO application and fee are required for the SWM and ESC plan review.
Rev. 1) A WPO application has not been submitted. The minor amendment should not be
approved until the WPO plan is received and approved.
The following are unofficial WPO plan comments that must be addressed with the WPO application.
1. The new drop inlet should be a DI -3A so that the Filterra hydraulics are more likely to work properly
in the field. Spot elevations on the pavement at the throat of the Filterra and curb inlet should be
provided.
2. Please specify the size of the Filterra.
3. An approval letter from Filterra is required.
4. The ESC plan required as a condition of the critical slope waiver must be a full plan including all
applicable items in the design manual checklist.
err
County of Albemarle
Department of Community Development
Memorandum
To:Gerald Gatobu, Current Development Project Planner
From:Phil Custer, Current Development engineering review
Date:1 April 2009
Subject: Humagen Minor Amendment (SDP- 2009 - 00017)
The minor amendment for the Humagen Facility has been reviewed. Engineering review for Current
Development can recommend approval to the minor amendment after the following comments have been
addressed:
1. Critical slopes are disturbed with this application and this disturbance requires a waiver. These critical
slopes were created with the construction of site plan SDP -1996 -00030 and are likely not designated
on the county's open space plan. Therefore, the disturbance shown in this plan is eligible to be waived
by the Director of Current Development, unless the application is called up to the Planning
Commission. Before the Director can waive such disturbance, the Zoning Ordinance requires the
approval of an Erosion and Sediment Control Plan beforehand. Approval of an ESC plan will likely be
a condition of Director's granting of the critical slope waiver. The engineering review of the critical
slope waiver will be given in a separate document.
2. The parking lot should be graded in such a manner that no slopes steeper than 5 %, other than in the
transitional area at the entrance from the travelway, exist. This appears to be possible by moving the
468 contour line and still keeping the corner of the lot at 467. (Please see the sketch at the end of this
memo.)
3. The hatched area in the upper parking lot should be a curbed island. [18- 4.12.15.f]
4. Please provide a note on the pipe profile stating that the contractor is to provide a concrete transition
from the end - section to the bottom of the VDOT ditch.
5. VDOT approval is required for the proposed pipe outlet into public ROW.
6. A WPO application and fee are required for the SWM and ESC plan review.
The following are unofficial WPO plan comments that must be addressed with the WPO application prior
to site plan approval.
1. The new drop inlet should be a DI -3A so that the Filterra hydraulics are more likely to work properly
in the field. Spot elevations on the pavement at the throat of the Filterra and curb inlet should be
provided.
2. Please specify the size of the Filterra.
3. An approval letter from Filterra is required.
4. The ESC plan required as a condition of the critical slope waiver must be a full plan including all
applicable items m the design manual checklist.
Current Development
Engineering Review Comments
Page 2 of 2
1 1 i
rri
x 0 --....„is-411r, 4. ---,Air
1 cp Or 7
Zy-
I I 1 :;-`4 /NI.' ':''''
4,,2,.,... >--- '.-- ' T Z 46 - - 411, -'-`,...„. "._
A1I
Z 410 • 0 N,tP MC' '.: 411 . 4"'41:',.AO.I ! 7 Ag glj • ; .7? 6,1-410 - . 16.";›11 1 4" i1i•
r—
IV k '"•• 10°
libic,/:' ;,,,. '0 1 r r 411.. ZOO"
r...D
2).'-• .
1I0IT04l /7Il
it • - ' , - ' • •P-.Aik-I It'-'0:411fr-.'''''•-:eryiO., 44 •j
I' V:-riflik:,, '7 ' 7 *, /4 1I ' , ')--- '...
91Fillkl- '7,77::' u1iltiiitkaik.., - ;•"'. .
is. -,--,:'--.W .:Cr&1
1 'rr iit, * • * * * • 4 ./
x f
4
Aria
County of Albemarle
Department of Community Development
Memorandum
To:Gerald Gatobu, Current Development planning
From:Phil Custer, Current Development engineering review
Date:1 April 2009
Subject: Humagen critical slope waiver request (SDP- 2009 - 00017)
The critical slope waiver request has been reviewed. The engineering analysis of the request follows:
Description of critical slope area and proposed disturbance:
The critical slope disturbance on parcel 79 -4C is necessary for the construction of an additional 7 space
parking lot. The analysis provided in this report is based on the drawing dated 20 March 2009.
The entire critical slope disturbance occurs within 15ft of the ROW of Hunters Way. This area of critical
slopes is manmade.
Areas Acres
Total site 2.75 acres
Critical slopes 1.04 38% of site
Critical slopes disturbed 0.004 0.42% of critical slopes
Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable
alternative locations:
There are no exemptions for the proposed disturbance.
Compliance with Zoning Ordinance 18- 4.2.5.b:
Below is the section of the Zoning Ordinance that specifies instances where the Director of Current
Development may grant a waiver to allow critical slope disturbance. The engineering commentary
regarding the ordinance text is written in bold italics.
Waiver by the agent. In accordance with the procedures stated in section 2.5 of this chapter, the
agent may waive the prohibition of disturbing critical slopes on any parcel not within the Rural
Areas (RA), Monticello Historic District (MHD) or Village Residential (VR) zoning districts in the
following circumstances: (i) the critical slopes were created during the development of the
property pursuant to a site plan approved by the county; or (ii) the critical slopes will be disturbed
to replace an existing structure located on the critical slopes and the extent of the disturbance is
the minimum necessary to replace the existing structure with a new structure whose footprint
does not exceed the footprint of the existing structure. The agent may grant a waiver if he or she
finds that:
The zoning of this parcel is Light Industrial. The critical slopes were created with the construction of
site plan SDP -1996- 00030.)
Albemarle Co tnty Community Development
Engineering Review comments
Page 2 of 2
1. The property is not identified in the open space plan as one having any protected resources
and a field inspection has confirmed that there are no significant or critical features on the
property identified for protection in the open space plan;
The planner will determine whether these slopes are protected on the County's Open Space Plan.)
2. There is no reasonable alternative that would eliminate or reduce the disturbance of critical
slopes;
Due to the steep slopes existing on site, the current alignment of the 7 space parking lot is the only
reasonable option to provide those spaces.)
3. The developer or subdivider submitted and obtained approval from the program authority of
an erosion and sediment control plan, regardless of whether the area disturbed is Tess than ten
thousand (10,000) square feet; and
The applicant has not submitted an application for an Erosion and Sediment Control Plan.
Engineering review recommends that any administrative waiver for critical slope disturbance be given
with a condition that requires approval of an ESC plan.)
4. The developer or subdivider submitted and obtained approval from the county engineer of a
plan that describes how the movement of soil and rock, stormwater runoff, siltation of natural
and man -made bodies of water, the loss of aesthetic resources identified in the open space
element of the comprehensive plan and, in the event of the failure of a treatment works and
subsurface drainfield, a greater travel distance of septic effluent, will be mitigated through
design, construction techniques, revegetation, stormwater management and other best
management practices.
The Water Protection Ordinance Plan will address all concerns regarding siltation of waterbodies,
stormwater runoff and the movement of soil and rock. The existing septic field is located at the
opposite end of the property and disturbance will not encroach upon this area.)
To conclude, it appears that the plan meets all of the standard requirements necessary for granting of an
administrative critical slope waiver with the exception of the site plan having approval for Erosion and
Sediment Control. Engineering review recommends approval of this critical slope waiver on the condition
that the applicant obtains approval of an Erosion and Sediment Control Plan.