Loading...
HomeMy WebLinkAboutSDP200900040 Plan - Other (not approved) 2009-05-11PETER JEFFERSON PARKWAY & WILLIS DRIVE AT MARTHA JEFFERSON HOSPITAL CAMPUS RIVANNA DISTRICT ALBEMARLE COUNTY, VIRGINIA ROAD AND DRAINAGE DESIGN PLANS PETER JEFFERSON PARKWAY MAJOR PLAN AMENDMENT OWNER/DEVELOPER: MARTHA JEFFERSON HEALTH SERVICES CORPORATION 459 LOCUST AVENUE CHARLOTTESVILLE, VIRGINIA 22905 PHONE NO.: (434) 982-7303 FAX NO: (434) 982-7324 ATTN.: MR. RONALD J. COTTRELL, V.P E—MAIL: ronald.cottrell@mjh.org LEGEND oO—o__ SANITARY SEWER LINE —lf'— WATER LINE INDICATES LOTS WHICH MUST HAVE DRAINAGE IMPROVEMENTS INSTALLED PRIOR TO BUILDING PERMITS BEING ISSUED FOR THAT LOT. MIN. F. F. 177.00 INDICATES MINIMUM FINISHED BUILDING ELEVATION THAT CAN BE USED ON A SPECIFIC LOT IN ORDER TO GET BUILDING ABOVE THE 1% STORM ELEV. OR TO OBTAIN GRAVITY SAN. SEWER 174 PROPOSED FINISHED GRADE CONTOUR ELEVATION ® DENOTES FILL AREA (NO FINISHED CONTOUR SHOWN) DENOTES HOW LOT SHOULD BE GRADED FOR SURFACE DRAINAGE BEFORE YOU DIG CALL 1 -SW -552-7001 PROTECT YOURSELF. GIVE THREE WORKING DAYS NOTICE u ­.— „,.,FERIA: ENGINEER: VICINITY MAP PETER JEFFERSON PARKWAY 40 MPH DESIGN SPEED Slcale: 1" = 2000' MI`IIINM RO DOCENDTERLINE: R=480' MAX. SUPERELEVATION CROSS SLOPE=2.00% WILLIS DRIVE 30 MPH DESIGN SPEED 25 MPH POSTED MIIN. ROAD CENTERLINE: R=300' MAX. SUPERELEVATION CROSS SLOPE=NC RUMMEL, KLEPPER, & KAHL, LLP 801 E. MAIN STREET, SUITE 1000 RICHMOND, VIRGINIA 23219 PHONE NO. : (804)782-1903 FAX NO. : (804)782-2142 ATTN.: RACHAEL T. McKINNEY, E.I.T. EMAIL: rmckinney@rkk.com PROPOSED EXISTING 0 ASPHALT PAVEMENT ® PAVEMENT 10 COVER SHEET ................ LINE 10 CULVERT OR STORM SEWER PIPE U Z �� Z ROAD SECTION SHEET SPROPERTY N AT SANITARY SEWER 0 DRAINAGE STRUCTURE NUMBER w — WATER LINE 19' OR 1B' INDICATES DRIVEWAY PIPE SIZE IF GREATER THAN 15" -- POWER LINE U DENOTES UNDERGROL 6 STORM DRAINAGE CALCULATIONS SHEET --- TELEPHONE LINE OH DENOTES OVERHEAD (S) OR (D) DENOTES SAN. SEWER (S) OR STORMWATER DRAINAGE (D) 3 GAS LINE 6 PETER JEFFERSON PLAN SHEET c = CULVERT OR STORM SEWER PIPE OF REGULAR SEEDED EARTH DITCH WITH DIRECTION OF FLOW —¢ FIRE HYDRANT OF CROSS HATCHING OF EITHER OF THESE INDICATES THAT PAVED DITCH IF SUITABLE VEGETATION CANNOT BE(' PETER JEFFERSON GRADING & DRAINAGE SHEET BENCH MARK LOCATION OF LINING MAY BE NECESSARY ESTABLISHED IN DITCH UNE. DRAINAGE PROFILE SHEET 5 OF EC -2 LINED DITCH WITH SEEDING -- 174 - EXISTING CONTOUR ELEVATION - PAVED LINED DITCH DRAINAGE PROFILE SHEET oO—o__ SANITARY SEWER LINE —lf'— WATER LINE INDICATES LOTS WHICH MUST HAVE DRAINAGE IMPROVEMENTS INSTALLED PRIOR TO BUILDING PERMITS BEING ISSUED FOR THAT LOT. MIN. F. F. 177.00 INDICATES MINIMUM FINISHED BUILDING ELEVATION THAT CAN BE USED ON A SPECIFIC LOT IN ORDER TO GET BUILDING ABOVE THE 1% STORM ELEV. OR TO OBTAIN GRAVITY SAN. SEWER 174 PROPOSED FINISHED GRADE CONTOUR ELEVATION ® DENOTES FILL AREA (NO FINISHED CONTOUR SHOWN) DENOTES HOW LOT SHOULD BE GRADED FOR SURFACE DRAINAGE BEFORE YOU DIG CALL 1 -SW -552-7001 PROTECT YOURSELF. GIVE THREE WORKING DAYS NOTICE u ­.— „,.,FERIA: ENGINEER: VICINITY MAP PETER JEFFERSON PARKWAY 40 MPH DESIGN SPEED Slcale: 1" = 2000' MI`IIINM RO DOCENDTERLINE: R=480' MAX. SUPERELEVATION CROSS SLOPE=2.00% WILLIS DRIVE 30 MPH DESIGN SPEED 25 MPH POSTED MIIN. ROAD CENTERLINE: R=300' MAX. SUPERELEVATION CROSS SLOPE=NC RUMMEL, KLEPPER, & KAHL, LLP 801 E. MAIN STREET, SUITE 1000 RICHMOND, VIRGINIA 23219 PHONE NO. : (804)782-1903 FAX NO. : (804)782-2142 ATTN.: RACHAEL T. McKINNEY, E.I.T. EMAIL: rmckinney@rkk.com TRANSITION OF SUPERELEVATION TO BE IN ACCORDANCE WITH NOTES: TC -5 ULS STANDARD. 1. ALL STORMI PIPE LENGTHS ARE MEASURED FROM CENTER OF' DRAINAGE STRUCTURES (D.I. OR M.H.) 2. ALL SAN. SEWER PIPE LENGTHS ARE MEASURED BETWEEN INSIDE SURFACES OF MANHOLES (UPPER STATION- LOWER STATION -4' = LENGTH) 3. CONTRACTOR IS TO MAKE HIS OWN TAKE -OFF ON THESE PLANS AS ANY OWANTITIES SHOWN ARE APPROXIMATE ONLY TO SHOW SCOPE OF WORK. 4. CONTRACTONR SHALL BE RESPONSIBLE FOR COMPLETION AND FINAL ACCEPTANCE OF ALL CONSTRUCTION AND UTILITY LINES. 5. CONTRACTOFR SHALL COMPLY WITH VIRGINIA STORM WATER MANAGEMENT PERMITS. A STORM WATER POLLUTION PREVENTION PLAN SHALL BE DEVELOPED) AND IMPLEMENTED BY THE CONTRACTOR FOR THIS CONSTRUCTTION ACTIVITY. NOTE: FOR EROSION & SEDIMENT CONTROL DETAILS REFER TO "MASS GRADING AND EROSION CONTROL, ROAD AND ROADWAY UTILITIES (VOLUME 1)" BY GRAEF ANHALT SCHLOEMER & ASSOCIATES, INC DATED 05/23/08. PLANNING DEPARTMENT ENGINEERING DEPARTMENT FIRE OFFICIAL A.C.S.A. V.D.O.T. BLDG. OFFICIAL BLDG. CODE & ZONING SERVICES wl INDEX SHEET NO. TITLE 1 OF 10 COVER SHEET 2 OF 10 GENERAL NOTES, DETAILS & TYPICAL U Z �� Z ROAD SECTION SHEET 2A OF 6 DRAINAGE DESCRIPTION SHEET 2B OF 6 STORM DRAINAGE CALCULATIONS SHEET 2C OF 6 STORM DRAINAGE CALCULATIONS SHEET 2D OF 6 DRAINAGE AREA MAP 3 OF 6 PETER JEFFERSON PLAN SHEET 3A OF 6 PETER JEFFERSON PROFILE SHEET 38 OF 6 PETER JEFFERSON GRADING & DRAINAGE SHEET 4 OF 6 DRAINAGE PROFILE SHEET 5 OF 6 DRAINAGE PROFILE SHEET 6 OF 6 DRAINAGE PROFILE SHEET TRANSITION OF SUPERELEVATION TO BE IN ACCORDANCE WITH NOTES: TC -5 ULS STANDARD. 1. ALL STORMI PIPE LENGTHS ARE MEASURED FROM CENTER OF' DRAINAGE STRUCTURES (D.I. OR M.H.) 2. ALL SAN. SEWER PIPE LENGTHS ARE MEASURED BETWEEN INSIDE SURFACES OF MANHOLES (UPPER STATION- LOWER STATION -4' = LENGTH) 3. CONTRACTOR IS TO MAKE HIS OWN TAKE -OFF ON THESE PLANS AS ANY OWANTITIES SHOWN ARE APPROXIMATE ONLY TO SHOW SCOPE OF WORK. 4. CONTRACTONR SHALL BE RESPONSIBLE FOR COMPLETION AND FINAL ACCEPTANCE OF ALL CONSTRUCTION AND UTILITY LINES. 5. CONTRACTOFR SHALL COMPLY WITH VIRGINIA STORM WATER MANAGEMENT PERMITS. A STORM WATER POLLUTION PREVENTION PLAN SHALL BE DEVELOPED) AND IMPLEMENTED BY THE CONTRACTOR FOR THIS CONSTRUCTTION ACTIVITY. NOTE: FOR EROSION & SEDIMENT CONTROL DETAILS REFER TO "MASS GRADING AND EROSION CONTROL, ROAD AND ROADWAY UTILITIES (VOLUME 1)" BY GRAEF ANHALT SCHLOEMER & ASSOCIATES, INC DATED 05/23/08. PLANNING DEPARTMENT ENGINEERING DEPARTMENT FIRE OFFICIAL A.C.S.A. V.D.O.T. BLDG. OFFICIAL BLDG. CODE & ZONING SERVICES wl W w W W LU O z J U Z �� Z Z CL N ICO Q mi HN O LU `— = z J z LX Lii Z Z CL > y D z Z W N U L6 LJ..F O J a W 0 m Q O a _ O:f N a oLU�� LU o C LU Y Lii Z Z = Q D W U /1T11A m o`` N 00 ! f o N 1voU J 9, O N W N F� N CV :3N W 0) Q et W?00 WOE 0; I � � M Z p rn Q�?DO W�D�o O �- O I— w LaJ N LLJ O U GENERAL NOTES - 1. EXISTING UTILITIES THE LOCATION OF EXISTING SEWER, WATER, POWER, GAS, TELEPHONE, AND OTHER UTILITIES AND STRUCTURES WHICH ARE LOCATED ACROSS, UNDERNEATH, ALONG AND WITHIN THE LIMITS OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS, AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE UNDERGROUND PROTECTION CENTER ("MISS UTILITY') AT 1-800-552-7001 AND, AT HIS OWN COST, VERIFY THE LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES WITHIN THE LIMITS OF CONSTRUCTION. HE SHALL NOTIFY THE ENGINEER IMMEDIATELY IF THERE APPEARS TO BE A CONSTRUCTION CONFLICT OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THE PLANS. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE GOVERNMENTAL PUBLIC WORKS AND PUBLIC UTILITY DEPARTMENT AT LEAST 24 HOURS PRIOR TO START OF WORK ON THE PROJECT. 2 MATERIALS AND WORKMANSHIP ALL MATERIALS AND WORKMANSHIP SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITIONS OF: " 12. SURVEY A. ELEVATIONS ON THE PLANS ARE TO DATUM ESTABLISHED BY THE N.G.S. OF THE N.O.A.A. B. ALL CONSTRUCTION STAKING WILL BE AT THE CONTRACTOR'S EXPENSE UTILIZING A VIRGINIA CERTIFED PROFESSIONAL ENGINEER OR LAND SURVEYOR UNLESS AGREED UPON BY THE OWNER IN WRITING. C. COPIES OF ALL SITEWORK CUT SHEETS ARE TO BE FURNISHED TO THE ENGINEER FOR HIS REVIEW PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE LIABLE FOR ANY ADVERSE CONSEQUENCES IF CUT SHEETS ARE NOT PROVIDED TO THE ENGINEER FOR HIS REVIEW PRIOR TO CONSTRUCTION. COST OF THIS REVIEW TO BE BORNE BY CONTRACTOR. D. ANY SURVEY POINTS (GRADE STAKES, OFFSET REFERENCES, HORIZONTAL AND VERTICAL CONTROL POINTS, ETC.) DESTROYED BEFORE THEIR NEED HAS EXPIRED WILL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 1.5" SM -9.5A ASPHALT 3.5" BM -25 ASPHALT r 21-A STONE SUBBASE (A) THE VIRGINIA DEPARTMENT OF TRANSPORTATION'S ROAD AND BRIDGE 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. SUBBASE COURSES PROVIDED A MINIMUM DEPTH OF 7" STANDARDS" AND "ROAD AND BRIDGE SPECIFICATIONS". COMPACTED SUBGRADE (B) APPLICABLE ALBEMARLE COUNTY ORDINANCES AND REGULATIONS. PETER JEFFERSON PARKWAY (C) THE LATEST RULES AND REGULATIONS GOVERNING CONSTRUCTION DEMOLITION Q O AND EXCAVATION AS ADOPTED BY THE SAFETY CODES COMMISSION OF THE STATION 100+00 TO STATION 118+50 4000 PSI IF PRECAST. COMMONWEALTH OF VIRGINIA AND OSHA. PAVEMENT DETAIL 3 DEVIATION FROM PLANS NO SCALE NOTE: FINAL PAVEMENT DESIGN SHAL 8 NO DEVIATION FROM THESE PLANS WILL BE ALLOWED WITHOUT PRIOR WRITTEN SUON DETAIL I L VERIFY SOILSERR S CBR ASTr CBR/PAVEMENT APPROVAL OF THE OWNER, ENGINEER AND AFFECTED GOVERNMENTAL AGENCIES. ANALYSIS. 4 CLEARING AND GRUBBING Y A. ALL GROWTHS OF TREES, OTHER VEGETATION AND OBJECTIONABLE DEBRIS 1.5" SM -9.5A ASPHALT DRAINAGE LAYER, THE BOTTOM OF THE CURB SHALL BE CLEARED AND GRUBBED FROM THE AREAS OF PROPOSED AND GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF SUBBASE COURSES vi 0 W LIJ..I 6" BM -25 ASPHALT �. Z CONSTRUCTION AND GRADING SHOWN ON THE PLANS. Q W B. ALL CLEARING AND GRUBBING WITHIN THE UTILITY EASEMENTS AND SPECIAL 0 LLJGo .. 12" 21-A STONE SUBBASE o a FILL AREAS SHALL BE TO THE LENGTH AND WIDTH NECESSARY TO CONSTRUCT THE IMPROVEMENTS SHOWN ON THE PLANS. C ALL TREES BRANCHES, VEGETATION AND DEBRIS SHALL BE DISPOSED OF COMPACTED SUBGRADE IN A LEGAL MANNER ACCEPTABLE TO THE OWNER AND ENGINEER. BURNING PETER JEFFERSON PARKWAY PERMITS WILL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE. D. ALL TREES AND VEGETATION WHICH OBSTRUCT SIGHT DISTANCES AT ROAD STATION 118+50 TO STATION 128+50 INTERSECTIONS SHALL BE REMOVED TO OBTAIN THE REQUIRED SIGHT PAVEMENT DETAIL DISTANCE AT EACH INTERSECTION. NO SCALE 5 TOPSOIL STRIPPING NOTE: FINAL PAVEMENT DESIGN BASED ON ACTUAL CBR RESULTS BY ING CONTRACTOR SHALL REMOVE TOPSOIL TO ITS ENTIRE DEPTH FROM ALL ED MA MARCHCH 09, 2009. AND ROBERTSON, INC. DATED AREAS TO BE GRADED AND OR FILLED. HE SHALL STOCKPILE OR REMOVE THE TOPSOIL FROM THE SITE AT OWNER'S DIRECTION. 6. GRADING A. ROADWAYS, EASEMENTS, AND SPECIAL FILL AREAS TO BE GRADED AND COMPACTED TO THE FINISHED SUBGRADE OR GRADES AS SHOWN ON THE PLANS. CONTRACTOR OR OWNER SHALL HAVE REPRESENTATIVE SUBGRADE CBR TESTS CONDUCTED AND SHALL REPORT TO THE OWNER, ENGINEER, AND ANY AFFECTED GOVERNMENTAL AGENCIES ANY TESTS WHICH SHOW A CBR OF LESS THAN 10. IN SUCH CASES, ROAD PAVEMENT DESIGN WILL BE REEVALUATED AND MAY BE CHANGED AS REQUIRED BY THE ACTUAL SOIL CONDITIONS ENCOUNTERED. B. UNSUITABLE MATERIAL ENCOUNTERED WITHIN THE AREAS OF CONSTRUCTION SHOWN ON THE PLANS SHALL BE COMPLETELY REMOVED FROM THE AFFECTED AREA AND REPLACED WITH A SELECT BACKFILL MEETING THE REQUIREMENTS FOR THE TYPE OF WORK BEING PERFORMED. THE CHARACTERISTICS OF THE SELECT BACKFILL MATERIAL SHALL COMPLY WITH SPECIFICATIONS REQUIRED BY ALL OF THIS PROJECT'S APPROVING AUTHORITIES (I.E., THE OWNER, ENGINEER, AFFECTED COUNTY AGENCIES, AND VDOT). C. FILL AND BACKFILL MATERIAL SHALL BE COMPACTED TO 95% STD. PROCTOR DENSITY AT OPTIMUM MOISTURE +-2% UNLESS SPECIFIED OTHERWISE ON THE PLANS. D. ALL GRADING OPERATIONS SHALL BE CONDUCTED IN A MANNER WHICH PROVIDES POSITIVE DRAINAGE AT ALL TIMES. E. THE BACK SLOPES OF CUT DITCHES SHALL BE MODIFIED AS NECESSARY TO PROVIDE REQUIRED SIGHT DISTANCE AT INTERSECTIONS AND THROUGH CURVES. F. VDOT STANDARD SPRING BOXES (ST'D. SB -1) AND UNDERDRAIN SYSTEMS (ST'D. UD -1, ST'D. UD -2) WILL BE INSTALLED AT LOCATIONS SHOWN ON THE PLANS AND WHEREVER FIELD CONDITIONS WARRANT. 7 DRAINAGE STRUCTURES AND MINOR EXCAVATION A. ALL PIPE CULVERTS AND STORM SEWER SYSTEMS SHALL HAVE A MINIMUM COVER OF 1 FOOT AND BE MADE OF THE MATERIAL SPECIFIED ON THE PLANS. ALL STORM SEWER SHALL HAVE A MINIMUM OF a INCHES AGGREGATE BEDDING MATERIAL. B. BACKFILL FOR ALL UTILITIES WITHIN PROPOSED STREETS SHALL BE PLACED GENERALLY IN ACCORDANCE WITH ALBEMARLE COUNTY UTILITY SPECIFICATIONS AND THE FOLLOWING CRITERIA: 1) NO TRENCH SHALL BE BACKFILLED UNTIL AUTHORIZED BY THE INSPECTOR OR OWNER OR HIS AUTHORIZED REPRESENTATIVE. MATERIALS USED FOR BACKFILL FROM THE TRENCH BOTTOM TO 12 INCHES ABOVE THE PIPE SHALL BE SELECT MATERIAL, FREE FROM FROST, LARGE CLODS, STONES, AND DEBRIS. IT SHALL BE THROUGHLY AND CAREFULLY COMPACTED TO INSURE A SOUND BACKFILL AROUND AND OVER THE PIPE. 2) BACKFILL SHALL BE COMPACTED BY MECHANICAL TAMPING THROUGHOUT THE DEPTH OF THE TRENCH TO OBTAIN 95% DENSITY AT OPTIMUM MOISTURE+ -2%. THIS IS TO INSURE A SUITABLE SUBBASE ACCEPTABLE FOR PROPOSED STREETS AND PARKING AREAS. 3) IF IN THE OPINION OF THE OWNER, THE ENGINEER OR ANY AFFECTED GOVERNMENTAL AGENCY THE MATERIAL TAKEN FROM THE DITCH IS NOT SUITABLE FOR BACKFILL, IT SHALL BE REMOVED AND ACCEPTABLE MATERIAL USED FOR BACKFILLING SHALL BE OBTAINED. C. TRENCHES SHALL BE EXCAVATED TO A MINIMUM OF 4 INCHES BELOW THE BOTTOM OF THE BARREL OF THE PIPE AND A BEDDING SHALL BE PROVIDED AND INSTALLED OF SELECT MATERIAL SUITABLE TO MEET VDOT ST'D. PB -1 PIPE INSTALLATION REQUIREMENTS. TRENCHES SHALL NOT BE CUT OVER 16 INCHES WIDER THAN THE OUTSIDE DIAMETER OF THE PIPE UNLESS AN UNSUITABLE FOUNDATION MATERIAL IS ENCOUNTERED. 8. BASE AND PAVEMENT ITEMS A. SUBGRADE MUST BE CHECKED BY AFFECTED GOVERNMENTAL OFFICIALS, AND OWNER FOR GRADE, TEMPLATE AND COMPACTION BEFORE BASE IS APPLIED. B. BASE AND PAVEMENT MATERIALS SHALL MEET ALL 'VDOT' SPECIFICATIONS AND SHALL BE APPLIED IN ACCORDANCE WITH THE CURRENT 'VDOT' SPECI- FICATIONS. ALL MATERIALS MUST BE TESTED AND APPROVED BY 'VDOT' OR APPLICABLE GOVERNMENTAL AGENCY OFFICIALS PRIOR TO EMPLACEMENT. C. PAVING OPERATIONS SHALL NOT BE STARTED BETWEEN NOVEMBER 15 AND APRIL 1 WITHOUT WRITTEN AUTHORIZATION OF ALBEMARLE COUNTY OFFICIALS AND THE OWNER. D. WHEN USING PUG MILLED AGGREGATE BASE MATERIAL WHICH IS TESTED BY 'VDOT' OFFICIALS AT THE PLANT, THE TEST WILL BE GOOD FOR 90 DAYS ONLY. ADDITIONAL "IN PLACE" TEST SHALL BE MADE AFTER 90 DAYS. E. WHEN LOCAL BASE MATERIAL (TYPE II) IS PROPOSED FOR ROAD BASE, IT SHALL BE TESTED AND APPROVED BY 'VDOT' OFFICIALS PRIOR TO BEING USED. OWNER AND ANY AFFECTED GOVERNMENTAL OFFICIALS SHALL ALSO CHECK AND APPROVED LOCAL BASE MATERIALS FOR DEPTH, COMPACTION, AND CONSISTENCY ONCE IT HAS BEEN PLACED IN ROADWAYS. 9. ALL ENTRANCE PERMITS TO PUBLIC ROADS MUST BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE PRIOR TO CONSTRUCTION. ALL OTHER PERMITS NECESSARY TO UNDERTAKE THIS PROJECT MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO CONSTRUCTION (AT THE CONTRACTOR'S EXPENSE). 10. LONGITUDINAL DROP INLETS (ON GRADE) SHALL BE PLACED WITH THE THROAT ON THE SAME GRADE AS THE ADJOINING CURB AND GUTTER UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. 11. THE CONTRACTOR SHALL BE LIABLE FOR ALL DAMAGE TO ANY STRUCTURES OR PROPERTY RESULTING FROM NEGLIGENCE OR CARELESSNESS ON THE PART OF THE CONTRACTOR OR ANY OF HIS SUBORDINATES. PRIVATE AND COMMERCIAL ENTRANCES TYPE I Crusher Run Aggr. 0 0 0 6" Crusher Run Aggr. 25 or 26 STD. CG -6 ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7, ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE, CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). Albemarle County Engineering General Construction Notes for Streets 1. Construction inspection of all proposed roads within the development will be made by the County. The contractor must notify the Department of Community Development (296-5832) 48 hours in advance of the start of construction. 2. Upon completion of fine grading and preparation of the roadbed subgrade, the contractor shall have CBR tests performed on the subgrade soil. Three (3) copies of the test results shall be submitted to the County. If a subgrade soil CBR of 10 or greater is not obtainable, a revised pavement design shall be mode by the design engineer and submitted with the test results for approval. 3. Surface drainage and pipe discharge must be retained within the public right-of-way or within easements prior to acceptance by the County. All drainage outfall easements are to be extended to a boundary line or a natural watercourse. 4. Guardrail locations are approximate. Exact length, location and appropriate end treatments will be field verified at the time of construction. Additional guardrail may be required at locations not shown when, in the opinion of the County Engineer, or designee, it is deemed necessary. When guardrail is required, it shall be installed four (4) feet offset from the edge of pavement to the face of guardrail, and roadway shoulder widths shall be increased to seven (7) feet. 5. Where urban cross sections are installed, all residential driveway entrances shall conform to VDOT CG -9(A, B or C). 6. Where rural cross sections are installed, all residential driveway entrances shall conform to VDOT standard PE -1. 7. Compliance with the minimum pavement width, shoulder width and ditch sections, as shown on the typical pavement section detail, shall be strictly adhered to. TYPE 11 Asphalt Asphalt Conc. Type SM -9.5A O 165 Lbs. per S.Y. 6" BM -25 Asphalt 7" 21-A Stone Subbase 25' UD -4 TO BE INSTALLED UNDER CURB AND GUTTER THROUGHOUT CONSTRUCTION FROM STATION 11+00 TO 20 ON BOTH SIDES IN NORMAL SECTIONS AND ON THE LOW SIDE OF SUPERELEVATED SECTIONS. UD -4 ALSO TO BE INSTALLED UNDER CURB AND GUTTER ALONG PROPOSED TURNING LANE ON ROUTE 250. UD -4 TRENCH DEPTH TO 12" BELOW SUBBASE FOR PIPE PROTECTION DURING CONSTRUCTION. NOTE: VPD PER TRAFFIC STUDY BY WILBUR SMITH & ASSOC. DATED JULY 2, 1996. PHASE 1 VPD=10,300. 4 LANE ROAD DESIGN TRAFFIC O 80% (10,300)=8,250 VPD lu AWN A"00 if G'lIx�111Yi[I7►� PETER JEFFERSON PARKWAY POINT OF FINISHED GRADE STD. CG -2 r 2� STD. CG -2 =NOTE: FILL SLOPE 4:1 BEYOND STATION 127+00. fJ,:::::: 8"x6" TREATED "CORTEN" GUARD RAIL WOODEN POST "CORTEN" GUARD RAIL DETAIL (TYP (PER VDOT STANDARDS) N.T.S. STD. CG -6 STD. GR -2 0 2E 25' 2.51-+ -- 5'-----1 WILLIS DRIVE POINT OF FINISHED GRADE 2% -�i I° I� I� 7° -I --2.5'-I- 18' 8. Rood plan aapprovol for subdivisions is subject to final subdivision plat validation. Should the final plat for t1this project expire prior to signing and recordation, then approval of these plans shall be null and void. 9. All signs oor other regulatory devices shall conform with the Virginia Manual for Uniform Traffic Control Devices and the Albemarle County Road Naming and Property Numbering Ordinance and Manual. 10. Traffic conhtml or other regulatory signs or barricades shall be installed by the developer vwhen, in the opinion of the County Engineer, or designee, they are deemed necesssary in order to provide safe and convenient access. 11. The speed limits to be posted on speed limit signs are 5 mph below the design speed, or as ddetermined by VDOT for public roads. 12. VDOT standdord CD -1 or CD -2 cross -drains to be installed under the subbase material at all cut and fill transitions and grade sag points as shown on the road profiles. es. 13. A video caomero inspection is required for all storm sewers and culverts that are deemed inooccessible to VDOT or County inspections. The video inspection shall be conducted in accordance witch VDOT's video camera inspection procedure and with a VDOT or County inspectcor present. 50' R/W SEE NOTE 4 STD CG -6 2% zi �I 1' i-- 18' 2.5°�+- 7' �4'�//�2" R SURFACE BASE im 4" 2" R D 6, 7" ♦ ♦ s s - -- - - - - - - 2'-0" l THIS AREA MAY BE CONCRETE / �+p AT THE OPTION OF THE CONTRACTOR NOT TO SCALE THE BOTTOM OF THE CURB AND GUTTER MAY BE CONSTRUCTED NOTES: PARALLEL TO THE SLOPE OF 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. SUBBASE COURSES PROVIDED A MINIMUM DEPTH OF 7" 2. CONCRETE TO BE CLASS A3 IF CAST IWLACE, IS MAINTAINED. NOTES: 4000 PSI IF PRECAST, 3. CURB HAVING A RADIUS OF 300 FEET. OR LESS (ALONG 1. THIS ITEM MAY BE PRECAST OR! CAST IN PLACE. FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. Q O 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" 4000 PSI IF PRECAST. (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) QZ IN ORDER THAT THE3. F CURB WILL BOTTOM 0 COINCIDE LL CO C COMBINATION CURB &GUTTER HAVING A RADIUS WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OF 300 FEET OR LESS (ALONG FACE OF CURB) SHALL OTHERWISE THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT BE PAID FOR AS RADIAL COMBINATION CURB & IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN GUTTER. INCREASE IN DEPTH. Y Z Z 4. FOR USE WITH STABILIZED OPEN -GRADED 5. CG -2 IS TO BE USED ON ROADWAYS MEETING THE DRAINAGE LAYER, THE BOTTOM OF THE CURB REQUIREMENTS FOR CG -6 AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL. AND GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF SUBBASE COURSES AND TO THE DEPTH OF THE PAVEMENT. STANDARD T A1� D ARD 6" CURB (CG -2) 5. ALLOWABLE CRITERIA FOR THE USE OF I`V��%I`V� V ftp ` CG -6 IS BASED ON ROADWAY CLASSIFICATION AND DESIGN SPEED AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL. COMBINATION 6" CURB & GUTTER (CG -6) F- LSI W LL 0 N O I W o J w V Z C) N C4 Q J a C4 o�_ '.I. Z w s� Q O V) Q Z (n V) -1 z QZ N O o Z >- w O >' o U Y Z Z W LLI 0 w V� W vi 0 W LIJ..I w ~ Z Z Q W 2 �X U 0 LLJGo .. a o a QQ W a W �>_ MIA a1 00 i � �Q` J o0 � W F a Z S?�y o 2 X00 C4 v, O J CX C N O r. WW O W Y a O a0 LLI Z U m Q Z Z Q W U 0 .. MIA a1 00 i � �Q` J o0 � W F a Z S?�y o 2 X00 STORM SEWER TABULATION FORM Road: Units: Metric (SI) Sheet _ of Project# X US Customary Prepared Ch eked by: Dab: 511112009 �I W W LLJ U. x 0 Q \ N I � Z N LQ i N N O z zLLJ Z J LLJ W Z CL > v) JORDAN CONSULTING ENGINEERS, P.C. MASTER DRAINAGE ANALYSIS z Z "PETER JEFFERSON PARKWAY PHASE II" w C) o Z W N"o0 SuenaWo: Pe1t®1 Jefferson Road (090( LL LL I J W6 0 JCE ORAINAOE ANALASIS REPORT W m O � Gnsas EWV In Out Q NON a )J 1 L Q (EX. 5-7) ~ U (EX. 5-11) (EX. 5-12) tT O I \ z 04 O W 2 O W .t j� 00 Z z a = m D W 0 U O' 4 NCO Ok' VI 007 \Z o Z JCE DRAINAGE AREA MAP w �No�P000J 0 O N Iw- Cn J N LIJ _ � � M 0) ZOO 04 0 CO C \' y w W DRAINAGE � HYDRAULIC GRADELINE � X i > a m' AND AREA (so. or he.) = _ ELEVATION O W A: CV E E REMARKS LOCATION = Q t � E 0 a0 � o a o W � `o `o CROWN ELEVATION � W j � E 'u ZONE OR COUNTY: UPPER ENO � v � E w E C Y z FLOWLINE ELEVATION E K C FREQUENCY: � E COMPOSITE F = ``e LL Q `o a a CFUIIN NAME F `o � � f O O < NET WORK NAME: m W K K ✓� < � W a�j i E UPPER O V O U F �,��UOw E !EOWLOWER�m<Wo o4'H� NOTES/REMARKS STATION O o ,. N 2 w PE RJ 5-10 518.97 519.88 0.28 0.52% 3.13 727+29.27 35 Rt. S9 DI -388 Curb 82.87 0.90 0.21 0.18 5.39 0.39 8.42 0.185 7.19 523.50 520.59 520.29 0.30 125 0.50% 3.17 4.93 519.34 519.04 0.30 PETER) 5-9 519.88 518.76 3.52 1.97% 5.48 727+75.00 A Lt. S8A DI -38 8 Curb 162.39 0.90 0.06 0.08 5.88 O.dB 6.29 0.242 1.52 523.81 520.19 517.07 3.12 7.25 1.95% 3.41 9.71 518.94 515.82 3.12 PETER) 5-9A 516.46 514.25 2.21 2.02% 5.87 DI -3B Curb 112.70 0.90 0.14 0.13 8.20 0.32 8.14 0.389 228 620.85 578.97 515.08 1.91 1.25 9.17 129+38.82 -4 Lt 53 16 7.74% 3.88 515.72 513.81 1.97 PE7ERJ 53 513.87 511.88 2.19 14.91% 11.76 DI -38 Curb 17.99 0.90 0.12 0.11 622 0.03 8.05 0.477 2.89 519.25 514.05 512.58 1.47 1.25 22 130+50.51 ♦ Lt. 5-17 76 512.80 511.33 1.47 10.00% 4.20 PETER) EX. 5-7 514.51 571.58 2.83 7.37% 8.45 DI -3C Curb 38.97 0.90 0.34 0.30 822 0.10 0.42 0.305 1.91) 579.57 513.2D 512.30 0.90 1.00 11 130M4.86 -35 Lt. EX. S-11 12 512.20 511.30 0.90 2.53% 3.72 PETER) EX. S17 512.28 504.78 7.48 2.95% 8.48 130+66.78 -5.85 Lt. EX. 5-12 A81-1 JlnchOn 255.77 0.90 0.87 0.00 8.73 0.50 8.04 0.782 4.72 518.00 512.41 505.45 6.96 1.25 2.74% Label 40 OA 0 Iraet Area (acreo) IMat C imel CA 4acree) PWa Flow TMe Upn) re (mY0 1 (IOAu) 6ec6on Site t.oe9m (R) alms (flap rural System FIM (ofs) na (cr) A1ro Vel (Ab) eget L (8) OWler Depth (A) ck,(ur Corea 9rpe 6N0 Carry mar Fbw ids) Cog EA (%) - Gtdtx DAd, Spread 00 seta Arype (deysae) INet "T O�e M) HvdraWo Out (Po Rua M) InvMl (A) invert (ft) Blma � 15.00 5.10 1.81 72.00 0.23 OA83 O.OD 700.0 5.35 Curd D138 614.90 514.84 81x.30 61x30 614.30 25 0.82 5.10 75 d%Ir 38.60 0.0772 ibt 17.JA 265 74.87 614.tMT 873.83 61x90 611,70 ftlle 25A 0.43 0.35 0.24 2.89 16.00 0.26 0.083 0.00 9x2 7.74 Curb D136 909.dD 80:1.46 611.26 60200 502.00 27 7.03 15.00 6.70 0.58 0.67 OAO 6.10 16 Inch 67.00 0.0053 2.89 4.89 2.35 7Q.60 603.x8 603.34 60200 501.70 /are 2'7A 6.OD 8.08 3.13 12m oy{ O.tIB3 0.00 11.5 5.46 5 11 612.t0 Sta.43 610.36 610.96 517.18 504.20 6.98 Label 40 OA 0 Iraet Area (acreo) IMat C imel CA 4acree) PWa Flow TMe Upn) re (mY0 1 (IOAu) 6ec6on Site t.oe9m (R) alms (flap rural System FIM (ofs) na (cr) A1ro Vel (Ab) eget L (8) OWler Depth (A) ck,(ur Corea 9rpe 6N0 Carry mar Fbw ids) Cog EA (%) - Gtdtx DAd, Spread 00 seta Arype (deysae) INet "T O�e M) HvdraWo Out (Po Rua M) InvMl (A) invert (ft) Blma � 15.00 5.10 1.81 72.00 0.23 OA83 O.OD 700.0 5.35 Curd D138 614.90 514.84 81x.30 61x30 614.30 25 0.82 5.10 75 d%Ir 38.60 0.0772 ibt 17.JA 265 74.87 614.tMT 873.83 61x90 611,70 ftlle 25A 0.43 0.35 0.24 2.89 16.00 0.26 0.083 0.00 9x2 7.74 Curb D136 909.dD 80:1.46 611.26 60200 502.00 27 7.03 15.00 6.70 0.58 0.67 OAO 6.10 16 Inch 67.00 0.0053 2.89 4.89 2.35 7Q.60 603.x8 603.34 60200 501.70 /are 2'7A 6.OD 8.08 3.13 12m oy{ O.tIB3 0.00 700.0 5.46 Curb DI3B 613.83 612.t0 Sta.43 610.36 610.96 28 0.36 s.oa tsmen 24zso oozat 3.13 1os4 eaz 2x63 e1210 soa.ee 611.36 5oa.43 tare zsA oaa ole oer 5.01 6.58 8.00 0.19 oA83 Om 1p0.0 3.16 Curb DI3B 170334 502.83 SOB.73 801.80 601.80 26 78A 0.20 OJ% 0.13 0.30 5.00 5.01 16 Nrcll 749.50 0.037/ 8.88 12.84 827 0.18 602.83 498.81 8(11.80 606.97 tette 2B 1.71 16.00 6m 224 14.00 025 oA63 0.00 .0 100Do 6.70 Curb DI -313 x8280 46289 600.08 462.00 482.00 29A oa0 o.4a o27 s.0016u,m 36.60 oma 224 ale 226 8873 49287 492.85 4e2.00 4e1.eo few 31 tae 1600 s.to zee u.00 o.za ose3 0.0o taco e.� Curb 01-M 479.86 47&87 aaa6a an.7o 4n.7o 9fA 0 .37 0&1 0.29 6t01e hroh 37.00 OA054 2.62 4.75 214 86.75 479.87 478.61 47/.70 47/.50 fere 30 487 8.78 482.66 x82 80D.73 497.70 401.70 30A 0.31 48716 nMh 175 -OD O.OS22 8.78 26.00 928 t.tt 482.88 483.70 491.70 4112.8§ Alae 32 ase tiz5 478.81 x7880 487.si an.40 snao 326 o.7a ase 24 kWh 20600 oaso2 11.26 Baee ae4 as.s2 a7aep 46aes 4n.ao 497.06 fare 33 i.$i 1soo as7 1s.20 1a.ao 026 O.OB3 aro t000 CuNiX39 x68.68 485.88 x:1.73481)36484.6633A 0.36 0.43 087 4.87 29 meh 31.80 0.02170 7320 31.991.38 78.354.98 4%.00 a84.�4)34.021tlN3480.176007201.068m020 0.083O.Op100 Curb0138460.98480.95468.152460.1848t7.ie34C 0.86 0.14 0.49 7.20 16meh 3200 08208 1.04 928 1.08 80.06 46096 46085 480.t8 45962 false3aon6.maset5.66tempeaodeatons ]47 curoa3e 461.78 463.96 rrosa 482.52 462.62 34A o.e3 o.a9 o.2e a.es 2a 97x, 144.00 0.0209 16.69 32.60 a4o 28.49 x63.&6 4eo.61 x62.62 480. faW Sao a.e3 ts.te Z. 4eoss 48086 aesee ato.so 459.e0 3aE ooz 4x3 24 Inch 10;60 o.o21e 1816 7.x6 our 48086 aeo.ae 4eeso 469.27 rew OUT aa3 1a7s 480ae 400.46 48x46 45DZ7 x6827 DRAINAGE AREA DESCRIPTIONS O0.04 Ac. c- 0 3-1 c• 0.90 tc- 5 min. DA- Ac. 3-2 c= 0.655 tc- 5 min. OOJ6 Ac. c- 0 3-3 c- 090 tc 5 min. O029 Ac. c- 0 3-4 c- 090 tc- 5 min. OOJ7 Ac. c- 0 3-5 c- 0.90 tc- 5 min. ODA- 039 Ac. 3-6 c- 090 tc- 5 min. ODA• 0.09 Ac. 3-7 c• 090 tc- 5 min. ODA= 020 Ac. 3-8 c- 0.60 tc- 5 min. OD.A - 0.05 Ac. 3-9 c• 0.90 tc- 5 min. DA• 028 Ac. 3 /0 c- 090 tc- 5 min. DA- 0.67 Ac. 3 II c- 0.60 tc- 5 min. DA- 0.08 Ac. 3 l2 c- 0.65 tc- 5 min. DA- 0.05 Ac. 313 c- 0.65 tc- 5 min. DA- 1.68 Ac. 3 l4 c- 0.35 tc- 5 min. O OA- 0 Ac. 3-15 c- 0.90 tc- 5 min. DA= 026 Ac. 3 /6 c- 035 tc- 5 min. DA- OJI Ac. 3 20 c- 090 tc- 5 min. DA- 1590 Ac. 3 22 c- 0.63 tc- 5 min. DA= 036 Ac. 3 23 c= 0.60 tc= 5 min. DA- OJI Ac. 3 24 c- 090 tc- 5 min. ODA- 020 Ac. 4-1 c• 090 tc- 5 min. ODA• 022 Ac. 4-2 c= 090 tc- 5 m1n. ODA- Ac. 4-3 c- 0900 tc- 5 min. DA= OJO Ac. 4 4 c- 090 tc- 5 min. OD.A - 028 Ac. 4-5 c- 0.80 tc- 5 min. ODA- 023 Ac. 4-6 c- 090 tc- 5 min. DA- 020 Ac. 4 7 c= 0.75 tc- 5 min. OcOJ6 Ac. c- 0 4-8 - 090 tc- 5 min. ODA= 03/ Ac. 4-9 c- OBl tc- 5 min. O DA- OJ5 Ac. 5-1 c- 090 tc- 5 min. ODA- 0.02 Ac. 5-2 c= 090 tc- 5 min. DA- 0.08 Ac. 5 3 c• 056 tc- 5 min. DA- 027 Ac. 5 4 c- 082 tc- 5 min. DA- 0.07 Ac. 5 5 c- 0.62 tc- 5 min. ODA. 0.04 Ac. 5-6 c- 090 tc• 5 min. O034 Ac. c- 0 5-7 c- 090 EXISTING tc- 5 min. OOJ2 Ac. c- 0 5-8 c- 090 tc- 5 min. 8 DA- 0.06 Ac. 5-g c- 0.90 tc- 5 min. DA- 02/ Ac. 5 /0 c- 090 tc- 5 min. D.A. 0.09 Ac. c- 0.67 tc- 5 m/n. O.A. OJ4 Ac. 5 9A c- 090 tc- 5 min. D.A. 0.06 Ac. 6 I c- 0.90 tc- 5 min. ODA- 0J3 Ac. 6-2 c- 0.90 tc- 5 min. O OOJ9 Ac. c- 0 6-3 c- 0.90 tc- 5 min. DA- 023 Ac. 6 4 c- 090 tc- 5 min. OcOJ7 Ac. c- 0 6-5 • 090 tc- 5 min. ODA- 024 Ac. 6-6 c• 090 tc- 5 min. OOA5 Ac. c= 0 6-7 c= 090 tc- 5 min. ODA• 007 Ac. 6-8 c• 090 tc- 5 min. ODA- 227 Ac. c- 0.60 6-y tc- 12 min. D.A. 0J2 Ac. 6 /0 c- 090 tc- 5 min. ODA• 027 Ac. 6 -ll c- 0.60 tc- 6 min. DA- OJ7 Ac. 6 /2 c- 090 tc- 5 min. D.A. OJ/ Ac. 6 /3 c- 090 tc- 5 min. DA- 0.42 Ac. 614 c- 0.60 tc- 8 min. D.A. 1.03 Ac. 615 c- 082 tc- l0 min. DA- OJO Ac. 6 l6 c= 090 tc- 5 min. DA -1.39 Ac. 617 c- 082 tc- l0 min. DA- OJO Ac. 6 /8 c- 0.90 tc- 5 min. OD.A. Ac. 6-19 c- 0800 tc- 5 min. DA- OJ9 Ac. 6 20 c- 090 tc- 5 min. ODA- 052 Ac. c• 0.60 tc- 5 min. OcOJ4 Ac. cm 0 6-23 - 090 tc- 5 min. DA- OJO Ac. 6 24 c- 090 tc- 5 min. DA- 03/ Ac. 6 25 c- 090 tc- 5 min. D.A. 2.05 Ac. 6 26 c- 088 EX/ST/NG tc- 9.49 min. D.A.- 0.34 Ac. 6 27 c- 080 tc- 5 min. D.A. 282 Ac. 6 30 c- 0.64 tc- l0 min. DA. 2.60 Ac. 6 3/ c- 0.60 tc- 12 min. DA- 6.0/ Ac. 6 32 c- 0.64 tc- IO min. 6-21 e� 0 c J �oILU F WU. y O Q V O SII OIN Ha OZZ N N Q J o J F L � Ha OZZ N N Q J o Z CL ' w C W � 40 mg Zi 2 o Q W N U W N6 L6 W w 0 a W W Z Q O � 19 N � K N o \ w 0 m W Y Q OW z z z Q W O U U m SEE SHEET 4 OF TMP• 78-311 SITE PLAN AMEND NT FOR ADDITIONAL INFORMA ON s ' a a STOPlGN \ S <�fd \ t 1 \ s ! g t t. � • J V ! / G ! 8 1 1 '0 5 7 d Q ? ��; STOP BAR l ' vr�. 0 ,c R2 / \ rr r ' i ti � \ y !!J ' JB dh" \ 1 r r l •1 T ``\ \\,\ , ,'('\eg \' jJ lJ //9! `\ dir \\ \\ \ 6-�, )p ,� a`':a:ik??:?`• 44 / NOTE. tp l B ♦<`<:> PARKING LOT T MODIFIED : , : EXISTING PARK 0 BE M00 i?;',�+ ;� , FOR WILLIS DRIVE IMPROVEMENTS PER SITE ' _ D" - AMENDMENT PLAN CONTAINED WITHIN MARTHA JEFFERSON HOSPITAL, FINAL COUNTYIR�dSkd: / A r _ 'a 1 J \ \ / f .• . u SITE PLAN REVISION RE SUBMITT AL yTr \_ r i 4.. ` "' "= a ,_ / fi / 'r f ! // B & I -.._ t A ' :;>I'4;:::' `::! j}%::' • 4A BY GRAEF USA DATED 09/04/08• $ f A /^ r / / O09 \ l d J, 'r f v A J 3 1 1t \ i r 8 i t ! B r \ J r r / • 1 P/ 4 t 02 22. 2 2 J 8 Y ( a - r\ t B 1 7 Y \ J \ u to .d / B r � r i LL ! r T I (R d A 3'' 50' 58.19' T1 DEL / a d ♦ ! e \ \ J { � s SE D 9' 2'5 7' 3 j t J> n I V d A v / l \ f \ ■ l t .% � T 7 7 d J \ \ 2.8 e a ^ c ♦ \ \ , \ � l4 3 t- a , L 5.0 v { L \ \ R ! P !�\ S EE µ� \ e v R \ \ \ 600.00' ® J $ r t \ a 'r t m \ I � 1 \ N \ u SG PC 20l 49.55 PT - 202+94.58 SE - NORMAL CROWN V - 30mph -R2-1 SPEED �} IT SIGN _. (TYP-) .� wslT�" � E ► 5 ool Pl -12 .7 RCP a �` • 5 '' X4.92' (RT) 5-4 D - li 56' l2' co T - 235.46' L - 437.81' R - 480.00' PC . 123.59.33 a PRC -127.97.14 SE - 2% V - 40mph ULS PROP. �C -- Rk HALL r'a°F,q 100' TURN LANE R2-1 SPEED EXIST. R/W LIMIT SIGN CO -2 Pl -129.64.37 DELTA - 36 59'13D4* (LTJ D - lr 2733' T - 1672Y + L 322. R - 500.00' PRC -127+97J4 PCC -131.19.91 SE - 2% V - 40mph ULS OUTPATIENT CAME CENTER PI -132.58.03 DELTA - 32.06' 24Jr (LT) D - If 56'10 T - 138J2' L - 268.98' R - 480.00' PCC -/3/•19.91 PT - 133.88.89 SE - 2% V - 40mph ULS SCALE 6 40' w (01 a W W o W u \at Q - V / Z Q z � o 0 Z J a. > E— Lj M) 0 W J a o, 0 3 L 0 \at � U) 0 V / Z Q z .-. 0 Z J a. > E— Lj O 0 W Lam! L y Z . Z :3 O V) W � U Z 116 :6 W WL W a J W W Q W M/ CL ao Q W� —j Q a O O cv O v- O W N J ~ Mco cv 04w �w Q o J w 00 LL, c+) z�rn 0� Z '5O� � W uj co o �- 00 � w J cc W N o, 0 3 0 \at � co .-. 0 Lo L W O co 0 W Y Q 00 Lu Z m Q Z =� O--.) W U Caj O O cv O v- O W N J ~ Mco cv 04w �w Q o J w 00 LL, c+) z�rn 0� Z '5O� � W uj co o �- 00 � w J cc W MgTCHL//VE ST 1 - I AT/Oiy i,S 6 00.00 0 i \`I� i SEE S//E w n n _ — `68 '-' 525 - /l \\ cti \ 1 I v /—Y/�/'Se�_t��//y/-#a,'�%�� \\\\� `t \�\� \II\\ 1 //d I j I / � �-�c. AiK —�'_I /``✓/I j I j � 1 / �`\ -.� _ / 'C la P/ — �— \ \\ \ \ / /• , to \ �� I I I '_ l` ��, ` �`.l i \ `a -z \ /`' 52 >G-- �-!_—/ 5 !� _ // "I ..-(( 'x ------------ I UL T 3C. '' _ r // / / / '' r�// i^�.Z'� ��. ` I 1� r7�•Z / i CA tVAUi `T, P JL Iil •\ Cn I /i 5/, / f� �� I / ' / // J / _ S<_:..�\ ail N/2O• \ , -_ — / t- `\-525 S2,� _ !?j�`�' 1 C> OOT9O N'' / W I W C ''// - d��..FS '�;,_�_ ����6114 8 1\ //� / Ld LL = U _ ': cTj ya\j`�-\ 'J''� iy `m.` S??. I I J / `7 l (l N N I, 2 A) 27-- 'A a 527 Sys �L 1—_ l l N,••„�/_ 7jli-! �' i!/ / / / // / ; / \� � �.-�M1�j �o'� � i/' /•• / s,� �// �,-`__ I T•�" :� // /// i'/�'���-- _�\ \ \ � 1\ I I 1 I ry � '�5 I -J\ u, \ ' a` I J /v LLI r�,t_�!S'�;'\ w % /' < / / / /: a �^♦ i! \ \ \ \ // 'rte=—t;i�.L��x \i!�"' \ *� \ — / �_ /i' ' /ii ` �-y /� ' / /NOTE: - \ I � a'Z (/1 , I `� \\\\-- / i- -i sK��_ --�_ - y /S'1 -2 r EXISTIIyd PARKING LOT, TOiBE MODIFIED \ I Z z 1\' , .� .`ak �� =-- �- t , �c `, ` _I �:_. — \l l J FOR %LCIS DRIVE l P EMENTS'PER SITE t \ { • r 5' / .v \ ---- /! M RSV 1 a J W :♦ t-, ,r c� / CUTa TIENT CPH'c CENT'En /�.._�\+�aa� ` .� =---�A%.Y%� --TTi' %�Y7%) %l._'a.--- - - " l = i / AME/�bMENT PLAN -CONTAINED WHIN - ----- i - C� --52 -1 —I — -MARTHA JEFFERSON HOSPITAL. FINAL COUNTY ,"' ;) `,.' .`• a �'=' x`'71`.`` _ —_ ' \ \Y I / / I M -+f • \\�+ CL ' Q i 1 _ 7_ / III/ I ; \ SIT PLAN REVISION RESUBMITTAL Z_ \R DATE 09/04/08. Z Q n BY AEF USA D �y�// C� I r^ U �l fi--52 / v' % / / in i / b /,. r. 4' i , \_ rr II I , \ \ 1 J ..P\f `�,//jt d' Sf / 7 .O' // A// n\ / i /, / — ' 'A ,--�.�.♦1--__-. ~ >`\\ \ tTI'%FF; ,�'�_ , _-\ \ \ / I I J/. /. Q ''V LU /' /�J•1a/'�''��V%/ N /' /Yi''"o . a -`c ♦♦a\\ /zi.� -_-. ___ _``-y..� \ I I I - __ / / //�J/ W !,� / rJ '..XXX..7i111 / �'/ f / % ', dy �— , -'..5� , /�r c. �S 1 \ / / j \ 1 // /, /� m V �G J:�'d✓e� / // �- // .'-a)« `` \ `�`"c•ia•� _ `.�� 1 _r A.. \ + �/a C""d \ ) / i' ( Q J / /'/ r+) al'..._/ t-'+ .l. a a •a ac _ _mss `` + \ \ 1 cJ'L 'r- r`S , 1 .iJ / Q Z O /`//^/ _ �, «/'! fb «`\ .. F-; dye' . ,♦, ` C•�. `'`..--52D ✓%/ rC�/\a`aY/z y\\\ \11t` r' ///,\� / `\; a / i a'. a� a-i�_�� `` n \R \ l l I I 1 1 \ - W' l\ \�-•'/.�a }� �%t `'"/ / / \\ / /� \ \\\ zo � '♦ i J �/ // // l/ l l/ I I \ \ 1 \I \5?4^-- \ / f \ / / /IJ / J `/ ♦ / �. s.� /' /�— / n // / ! ! 1 1 522-' 1 // T% -` \\\'i{ / // // .`E -ate__ //t.X n, /� j ll�r/l I 1 1 I /`--.. n\, \ \� ` , /♦.Ei '`^�_ t� T.� / / / / ' I // 521- -j �,,AN'�a\A N •\���,x X\` ' \(aA\\\\\\\ __ � O a�\ \ I a K„ s1^ i/i ` `` =` ", r �` / < ✓ I --. 1 �= I ✓j /Il� \1 I ytL // /\.,s?n s� //%yJJ"J/' / \ N 0--1 I /i /i, \. O \\ %J.,.��^,,' I. IsJ./ .a \\\\�I\ - / a -c _•c �5.'i a J' In /// / I I I l TOP / {1, \. \ \ .__ ' a ..�F • a�-,y� �i / /� / 1 1 1 to / / ` �•.l i. S2O /� / / J/ / / T� \ 2' m __ j-- _ /! /l \ -� a\\ �,����.i ' -� moi.-i-`�-'-"``" -.-y_Rg. 78 I /�— I\ _—_ �/� �l \ s�� N W O 2 O �! .�t y/k' ,�'\ _j-" :a\\\\\ "'�a '>�= `—r-_=— '_ �r� . K �`'( ^>r///� / / / I \ 8• On3yO9,O 1 \ `-/ // !/ I I \ .rii"�'i, /// / ,9� O W W Q O or _._ L, \ z / — _ +'` ?� €� ; _';,: / �/ 1 - \ / / h� \ is .- :: ;i! / Q Z 2 Q m ry.` k --t'"..-'' a--_. `.� d/' y ':— \� \ \ his• \ , h\ % '� . - / / / ' ,� 57 \ 4 te.\ eco B. <r- 0• 88 -P`2 �-; , .a. �+ \ \ \ \ m> � � —._� � \_ `_`�-�`•� ! � � `rte' I I /i /' �` � � 1 P. � .,.-f �y�'�♦AA� a .'' _ \ \l \ `Y} / .- � .� cc \K c�`\ \ �'' �> _V' V �:: . I �.l-"_-/'' /n �- i, .. -' .__----•.a.�� I \\ r c- j�.��� � .� �. F. VAUC S^ OVj, gJl �. � � / � Z � / 6 �`` �ECr V' �` Sy �'. 451- N, !IA'O3U OD LU LU �'�`` `` •`,�' \`, + `� %x \\\\� \ �—' / / / /// ./'� / / �' / '-�Y"W_.'�-Gi-` _ � � —_'__ 1 \ ``__ yrs .5 /%,,.// O \ ` " �+— _ — \ _ �� \ \1 \ 11 \ \ 1 (�� a —a� raacw ! cl 26'\ C'l 1 O N ~ U o Er o O 00 498- (' W SCALE \ C ob I 1