Loading...
HomeMy WebLinkAboutSUB201600060 Approval - Agencies 2016-03-23 %ftme -ore .0 COMMONWEALTH of VIRGINIA In Cooperation with the Thomas Jefferson Health District ALBEMARLE-CHARLOTTESVILLE State Department of Health FLUVANNA COUNTY(PALMYRA) 1138 Rose Hill Drive GREENE COUNTY(STANARDSVILLE) LOUISA COUNTY(LOUISA) Phone(434)972-6219 P. O. Box 7546 NELSON COUNTY(LOVINGSTON) Fax (4p23/20146310 Charlottesville, Virginia 22906 County of Albemarle Department of Community Development DDD "� ci-P 401 McIntire Road,Room 227 Charlottesville,VA 22902 RE: Review of Proposed Subdivision Plat as part of Tax Map 30-Parcel 9B1,located in Albemarle County,Virginia. To Whom it May Concern: On March 23,2016,the County of Albemarle requested the Virginia Department of Health(via the Albemarle County Health Department)review the proposed subdivision plat identified above.This letter is to inform you that the above referenced subdivision plat is approved for individual Onsite Sewage Systems in accordance with the provisions of the Code of Virginia,the Sewage Handling and Disposal Regulations, and local ordinances. This request for subdivision review was submitted pursuant to the provisions of§ 32.1-163.5 of the Code of Virginia which requires the Health Department to accept private soil evaluations and designs from an Authorized Onsite Soil Evaluator(AOSE)or a Professional Engineer working in consultation with an AOSE for residential development. This subdivision was certified as being in compliance with the Board of Health's Regulations by: Steve Gooch Onsite Soil Evaluator. This subdivision approval is issued in reliance upon that certification. Pursuant to § 360 of the Regulations this approval is not an assurance that Sewage Disposal System Construction Permits will be issued for any lot in the subdivision identified above unless that lot is specifically identified on the above referenced plat as having an approved site for an onsite sewage disposal system,and unless all conditions and circumstances are present at the time of application for a permit as are present at the time of this approval. This subdivision may contain lots that to do not have approved sites for onsite sewage systems. This subdivision proval does pertain to the requirements of local ordinances. • cerely, St en B. ar o Environmental 'ealth Specialist, Sr. Onsite Sewag /and Water Programs APPEED Soils Study for Drain Field Sites Parcel B3 A Division of TM 30-9B1 Albemarle County Prepared for: Harry Yoder 1012 Good Hope Road Aroda, VA 22709 Prepared by: Steve Gooch Consulting Geologist,Inc. 703 Oliver Creek Road Troy, Virginia 22974 March 21, 2016 Page 1 of 8 OSE/PE Report for: Construction Permit Certification Letter- Subdivision Approval R-11 Property Location: 911 Address: City: Lot B3 Section Subdivision GPIN or Tax Map# 30-9B1 Health Dept ID# Latitude Longitude Applicant or Client Mailing Address: Name: Harry Yoder Street: 1012 Good Hope Road City:Aroda State VA Zip Code 22709 Prepared by: OSE Name Steve Gooch License# 1940001284 Address 703 Oliver Creek Road City Troy State VA Zip Code 22974 PE Name: License# `"'` Address City State Zip Code Date of Report 3/21/16 Date of Revision#1 OSE/PE Job# Date of Revision#2 Contents/Index of this report(e.g., Site Evaluation Summary,Soil Profile Descriptions,Site Sketch,Abbreviated Design,etc.) OSE Cover Page Abbreviated Design Forms Soil Profile Sheets Survey Plat Soil Information Summary Sheets Certification Statement I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal Regulations(12 VAC5-610),the Private Well Regulations(12 VAC5-630)and all other applicable laws,regulations and policies implemented by the Virginia Department of Health. I further certify that I currently possess any professional license required by the laws and regulations of the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein. CThe work attached to this cover page has been conducted under an exemption to the practice of engineering,specifically the exemption in Code of Virginia Section 54.1-402.11 'N., I recommend that a(select one): construction permit❑ certification letter subdivision approval C be(select one)issued denied❑. OSE/PE Signature /2*4--- Date 9 f ati/G Soil Profile )90,e_ 2 eFF Primary Drain Field Parcel B3 A Division of TM 30-9B1 New- Albemarle County Hole Depth Horizon Material Description Soil Texture (in.) Group 1 0-2 A Dark gray(10YR 4/1) sandy loam, friable 2 2-14 E Light brown(7.5YR 6/4) sandy loam, friable 2 14-27 BC Yellowish red(5YR 5/8) sandy clay loam, friable 2 27-84 C Yellow(10YR 7/8) sandy loam, friable 2 2 0-3 A Dark gray(10YR 4/1) sandy loam, friable 2 3-30 Bt Brown(7.5YR 5/4) clay loam, friable 3 30-84 C Dark yellowish brown(10YR 4/6) loam, friable 2 3 0-3 A Dark gray(10YR 4/1) sandy loam, friable 2 3-7 E Light brown (7.5YR 6/4) sandy loam, friable 2 7-36 Bt Light red(2.5YR 6/8) clay loam, friable 3 36-64 Cl Yellowish brown (10YR 5/8) sandy loam, friable 2 64-84 C2 Dark yellowish brown(10YR 4/6) loam, friable 2 4 0-2 A Dark gray(10YR 4/1) sandy loam, friable 2 2-12 E Light brown(7.5YR 6/4) sandy loam, friable 2 Aim., 12-27 Bt Reddish brown (2.5YR 5/4) clay loam, friable 3 27-48 Cl Yellowish red(5YR 5/8) sandy clay loam, friable 2 48-84 C2 Strong brown(7.5YR 5/8) sandy loam, friable 2 5 0-3 A Dark gray(10YR 4/1) sandy loam, friable 2 3-7 E Light brown (7.5YR 6/4) sandy loam, friable 2 7-30 Bt Light red(2.5YR 6/8) clay loam, friable 3 30-49 Cl Yellowish red(5YR 5/8) sandy loam, friable 2 49-84 C2 Brownish yellow(10YR 6/8) sandy loam, friable 2 Page � of 1 Appendix 2 Soil Summary Report GENERAL INFORMATION Date 3/21/16 Submitted to Albemarle County Health Department Applicant Harry Yoder Telephone Number (434)981-8325 Address 1012 Good Hope Church Road Aroda, VA 22709 Owner same Address same Location Bleak House Road Tax Map 30-9B1 Subdivision Block/Section Lot 83 SOIL INFORMATION SUMMARY- S7vVc„r? oi=1'0-P1 1. Position in landscape satisfactory? (X Yes r No Describe shoulder 2. Slope 13 % 3. Depth to rock or impervious strata: Max. Min. None x 4. Depth to seasonal water table (gray mottling or gray color) Cx No 1` Yes inches -ree water present IX No 1— Yes range in inches 6. Soil percolation rate estimated IS Yes Texture group I 11 Ill IV fi No Estimated rate 45 min/inch 7. Permeability test performed E Yes 1-5Z No If yes, note type of test performed and attach Site Approved: Drainfield to be placed at 60" depth at site designated on permit. r Site Disapproved: Reasons for rejection: 1. E Position in landscape subject to flooding or periodic saturation. 2. I- Insufficient depth of suitable soil over hard rock. 3. IW Insufficient depth of suitable soil to seansonal water table. 4. E Rates of absorption too slow. 5. I— Insufficient area of acceptable soil for required drainfield, and/or Reverse Area. F (� Proposed system too close to well. 'Noir 1 Other Specify (attach additional pages if necessary) f G`x-- Y de-48- Abbreviated 1'48Abbreviated Design Form This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the 0 primary and reserve area, C-i'on1y the primary area, 0 only the reserve area(check one)for_Parcel B3 —A Division of TM 30-9B 1 . Design Basis Total length of available area: 100' Total width of available area: 40' Estimated Perc. Rate: 45 at 60" in. (depth) Number of bedrooms(or GPD): 4 1 2 Conveyance Method : _Pump Distribution method (specify): Pump 3c Dispersal system basis Table 5.4 LGMI required? No_(Yes/No) Effluent quality required: Primary (Primary, Secondary,Advanced Secondary) Square feet per bedroom: 344 _ Total trench bottom area required: 1376 Area Calculations Number of trenches 5 Length of trenches: 100' Width of trenches: 3' Center to center spacing: 9' Reserve required? Yes Percent reserve area required: _100 Total width of absorption area required 39' Total trench bottom area provided: 1500 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 Soil Profile row" if; Reserve Drain Field Parcel B3 A Division of TM 30-9B1 Noisy Albemarle County Hole Depth Horizon Material Description Soil Texture (in.) Group 1 0-2 A Dark gray(10YR 4/1) sandy loam, friable 2 2-14 E Light brown(7.5YR 6/4) sandy loam, friable 2 14-27 BC Yellowish red(5YR 5/8) sandy clay loam, friable 2 27-84 C Yellow(10YR 7/8) sandy loam, friable 2 2 0-3 A Dark gray(10YR 4/1) sandy loam, friable 2 3-30 Bt Brown (7.5YR 5/4)clay loam, friable 3 30-84 C Dark yellowish brown (10YR 4/6) loam, friable 2 6 0-2 A Dark gray(10YR 4/1) sandy loam, friable 2 2-13 E Light brown(7.5YR 6/4) sandy loam, friable 2 13-34 Bt Yellowish red (5YR 5/8) silty clay loam, firm 3 34-60 Bt2 Reddish yellow(7.5YR 6/6) sandy clay loam, friable 2 w/yellow(10YR 7/8)mottles 7 0-2 A Dark gray(10YR 4/1) sandy loam, friable 2 2-8 E Light brown (7.5YR 6/4) sandy loam, friable 2 '�- 8-43 Bt Reddish brown(2.5YR 5/4) clay loam, friable 3 43-84 C Dark yellowish brown(10YR 4/6) sandy loam, friable 2 Page 29 of 7 Appendix 2 Soil Summary Report GENERAL INFORMATION Date 3/21/16 Submitted to Albemarle County Health Department Applicant Harry YoderTelephone Number (434)981-8325 Address 1012 Good Hope Church Road Aroda, VA 22709 Owner same Address same Location Bleak House Road Tax Map 30-9B1 Subdivision Block/Section Lot B3 SOIL INFORMATION SUMMARY- l e.5-e4't,(e- pry Fiji 1. Position in landscape satisfactory? fg Yes f"- No Describe shoulder 2. Slope 13 % 3. Depth to rock or impervious strata: Max. Min. None x 4. Depth to seasonal water table(gray mottling or gray color) 5 No E Yes inches " cree water present GC No E Yes range in inches 'oil percolation rate estimated R Yes Texture group I II ® IV E No Estimated rate 80 min/inch 7. Permeability test performed E Yes fX No If yes, note type of test performed and attach rg Site Approved: Drainfield to be placed at 20" depth at site designated on permit. f Site Disapproved: Reasons for rejection: 1. E Position in landscape subject to flooding or periodic saturation. 2. fl Insufficient depth of suitable soil over hard rock. 3. E Insufficient depth of suitable soil to seansonal water table. 4. r Rates of absorption too slow. 5. r Insufficient area of acceptable soil for required drainfield, and/or Reverse Area. 6. E Proposed system too close to well. .,,f- Other Specify (attach additional pages if necessary) ?av_ 7 �� Abbreviated Design Form This form is for use with gravity,pump to gravity, enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the ❑ primary and reserve area, 0 only the primary area, 24nly the reserve area(check one)for Parcel B3 —A Division of TM 30-9B1 . Design Basis Total length of available area: 100' Total width of available area: 30' Estimated Pere. Rate: 80 at 20" in. (depth) Number of bedrooms(or GPD): 4 1 2 Conveyance Method : Pump Distribution method (specify): Pump 3c Dispersal system basis GMP#118A_ LGMI required? No (Yes/No) Effluent quality required: Seconds (Primary, Secondary,Advanced Secondary) Square feet per bedroom: 289 _ Total trench bottom area required: 1156 ftwir Area Calculations Number of trenches 4 Length of trenches: 100' Width of trenches: 3' Center to center spacing: 9' Reserve required?_This is reserve_ Percent reserve area required: 100 Total width of absorption area required 30' Total trench bottom area provided: 1200 The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available,especially up and down the slope,than is required. Page of AOSE Form E Revised July 18,2007 IC �BEARING�� LINE DELTA RADIUS ARC TANGENT CHORD CHORD Cl 2'08'23" 3305.75 123.46 61.74 123.45 S01 '56'45"E Opp C2 48 °08'25" 470.59 395.39 210.21 383.86 S24 '37'05"W EXISTING 15'R/W C3 22 '40'37" 182. 12 72.08 36.52 71.61 537 '20'59"W 3 GRAVE YARD C4 9'35' 10" 182. 12 30.47 15.27 30.43 821'13'06"W —(b"'8.312-520 PLAT) Z i , s. ?,2i T.M.30-360 '4'/ KEVIN W.HOCUTT •2�1 0.8.4354-479 4/' 0.8.4354-476 & 477 PLAT 0.8.3905-44 ,);0 T.M,30-98 0.8.3905-41 & 42 PLAT / af i • .4.r.....-'4\ / 30-3( `• -�� \\ ' 0o� JAMES F.HUCKSTEF • /' e W.8. 152-3F. �'/ '� `, .2af tit D.13.311_20 e T. M.30-`981 \ AY U0.8. 125-44D 8LI PARCEL 81 + E 1947532:80: ' ?'i`' ROGER W.RAY & ASS HARRY F.YODER / DATED JUNE 9, 0.8.4488-153 & 154 PLAT $73 .2&. � ` / RESIDUE- 4.31 0.8.3250-467 0.8.2663-643 & 644 PLAT '+. 170,08'TTAL ' 0.8. 1366-624 PLAT 7' IS 155.67' IF E11475482 n.8.691-709 PLAT ti;; 14 t ROUE=6.48+/- ACRES m Ni, .41 't`, SOS 47'41"E t + 112.85' \ tt a ^� PROPOSED tCt t t/J c' ORAINFYELO ' `t`t / ClC1 ti 4 AREA t, IF h .i, ' FLAG ` t� /% m FLAG 2 3 1 +2 'Q. t .4 , ► r 1 r r , ►1t► „1 . • • a,:-r • , , , t , '� L1 THRU L18 ARE L13 4; ^ r,,, , • I ; .1141 i 7 i 503.03' 15"W ALONG CENTERLINE L12 � ' • ca , , , , ' , , , OF STREAM 1 f o + A ,5A� , , 233.44 AS IT MEANDERS L �M o ; + ; �� +a MAJOR COURSES SHOWN o, S'(A� t ' ' I t , i� /�, 1 `r FLAG FL iAG FLAG t +a / (t' 01.4',.,, s •.i C 2: « Rimy /fi r Di ;'ca (43.48 ACRES) 1'�! ;•: •2% v ' i ►v SO2'57'21"E /44, Scale 1"= 100' o- Soil Profile Hole .6 t 'a IF 129.85' ,'�n,,,i House, Well and Drain Field Sites ,5 + 'm r A~y 5 t + Parcel 3B t o A Division of TM 30-9B 1 ., 19 � ' k+' // et, Albemarle Coun , Vir•inia ,� �`4: 4 ,s' AN `, % Ig i Steve Gooch Consulting Geologist `t , 19 6i "`'`°' �s� : q L21 ' , 1 IS PARCEL 7C liver Creek Road �::' 270.8 • • ' ' (� C VarVirginia 22974 -15.22,` 1 --�--�-•-- J 1 t•t,h . :ti ;` , ` f 370.0 :ST T A9E15/4T:"' 'X3.03' , '*4 7 .,, 4....4 �. •• �9 N3943053 742.87' TF 30-9A, VIRGINIA ELIZABETH GOLDEN, 0.8. 15741357 & 0.8.691-721 PLAT N3943025 1 , I W3 E114755541 , 1 0,8.3868-138, 0 Residue A Division of TM 30-9B I Albemarle County The residue parcel has a drain field with 100%reserve per Health Department Permit ID # 101- 15-0048.