Loading...
HomeMy WebLinkAboutARB201600038 Action Letter 2016-05-12Lrf2C;l1�ZA COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 May 9, 2016 Bob Pineo/Design Develop LLC 418 East Main Street Charlottesville, Va. 22902 RE: ARB -2016-38: Gropen Design & Fabrication Facility Final Dear Mr. Pineo, The Albemarle County Architectural Review Board reviewed the above noted item at its meeting on Monday, May 2, 2016. The Board, by a vote of 4:0, approved the request, pending staff administrative approval of the following conditions: 1. Key proposed materials to the elevations and include a material/color legend on the elevation sheets. 2. Indicate on the plans the VLT and VLR for the proposed window glass. Add the standard window glass note to the drawings: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. 3. Add the standard mechanical equipment note to the plan: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 4. Adjust the lighting design to eliminate spillover in excess of .5 fc at the property line along the EC. 5. Provide the cut sheets for the light fixtures on one of the site plan sheets. Note on the plan all options chosen for the fixtures. Ensure that all fixtures emitting 3,000 lumens or more are full cutoff fixtures. 6. If exterior building -mounted lights are proposed, include complete information on the plan. 7. Revise the light fixtures to have a consistent lamp type. 8. Confirm that no previously existing lighting is to remain. If there is existing site lighting to remain, include all relevant information on the lighting plan (locations, lamp type, fc levels). 9. Revise the lighting plan to identify the pole and fixture color. 10. Indicate on the lighting plan if bases are proposed for the light poles. If they are, adjust the design so that maximum pole height is 20', including the height of the base. Add a note to the plan confirming this. 11. Add the standard lighting note to the plans. "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle." 12. Revise the landscape plan to show the full extent of the EC frontage on the plan. 13. Identify trees by species that are intended to remain along the EC. Future landscape development along the EC will be required to meet EC Guidelines. 14. Correct all of the plant calculations on the landscape plan and show the required plants. Correct the frontage measurement on C0.1. Provide large trees along the entrance drive, 2'/2" caliper at planting, 40' on center. 15. Provide perimeter parking lot trees, 40' on center, 2'/2" caliper minimum at planting, along the southern parking row. 16. Add the standard plant health note to the plan. "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." 17. Confirm metal panel reflectivity is within range of panels approved for Albemarle High School and Regal Cinema. Please provide: 1. Two full sets of revised drawings addressing each of these conditions. Include updated ARB revision dates on each drawing. 2. A memo including detailed responses indicating how each condition has been satisfied. If changes other than those requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with "clouding" or by other means will facilitate review and approval. 3. The attached "Revised Application Submittal" form. This form must be returned with your revisions to ensure proper tracking and distribution. When staff's review of this information indicates that all conditions of approval have been met, a Certificate of Appropriateness may be issued. If you have any questions, please do not hesitate to contact me. Sincerely, Margaret Maliszewski Principal Planner Cc: Ronayne Llc 1766 Scottsville Rd Charlottesville Va 22902 File COUNTY OF ALBEMARLE Department of Community Development REVISED APPLICATION SUBMITTAL This form must be returned with your revisions to ensure proper tracking and distribution. County staff has indicated below what they think will be required as a resubmission of revisions. If you need to submit additional information please explain on this form for the benefit of the intake staff. All plans must be collated and folded to fit into legal size files, in order to be accepted for submittal. TO: DATE: PROJECT NAME: ARB -2016-38: Gropen Design & Fabrication Facility Final Submittal Type Requiring Revisions () indicates submittal Cade County Project Number # Copies Erosion & Sediment Control Plan (E&S) Mitigation Plan (MP) Waiver Request WR Stormwater Management Plan (SWMP) Road Plan RP Private Road Request, with private/public comparison (PRR) Private Road Request — Development Area (PRR-DA Preliminary Site Plan (PSP) Final Site Plan or amendment FSP Final Plat (FP) Preliminary Plat PP Easement Plat (EP) Boundary Adjustment Plat BAP Rezoning Plan (REZ) Special Use Permit Concept Plan (SP -CP) Reduced Concept Plan (R -CP) Proffers (P) Bond Estimate Request (BER) Draft Groundwater Management Plan (D-GWMP) Final Groundwater Management Plan (F-GWMP) Aquifer Testing Work Plan (ATWP) Groundwater Assessment Report (GWAR) Architectural Review Board (ARB) ARB2016-38 Other: Please explain (For staff use only) Submittal Code # Copies Distribute To: Submittal Code # Copies Distribute To: ARB 2 Margaret Maliszewski