Loading...
HomeMy WebLinkAboutARB201600054 Plan - Approved 2016-05-13EQ 3'-3" 16" 13'-2" SIGN 16" 3'-3" EQ EQ IGRAPHICI I GRAPHIC t (A)-scalp—ROPOSED STOREFRONT ELEVATION - TOTAL SIGN AREA 47.85 SF e: 3/16"=1'-0" petvalum Starlight National Signs 2014 111111INS PM By /your p- - THIS DRAWINARLIGHINCLUDES DATA THAT ISHALL PROPRIETARY NOT *LISTED 5-2 1. REVISIONS PER TOWN nn INFORMUCATE OR DISCLOSED IN SIGNS. IT SHALL NOT BE USED, V R M G � DUPLICATED OR DISCLOSED IN WHOLE OR PART FOR ANY PURPOSE OTHER THAN TO EVALUATE THIS PROPOSAL.. IFA Untle writers Labora[otles, Ina CONTRACT IS AWARDED TO THIS PROPOSER AS A RESULT OF OR COMMENTS PANTOPS SHOPPING CENTER IN CONNECTION WITH THE SUBMISSION OF THIS DATA, THE ELECTRICAL REQUIREMENTS DEFEREE SHALL HAVE THE RIGHT TO USE OR DISCLOSE THE DATA 2040 ABBEY ROAD TO THE EXTENT PROVIDED IN THE RESULTING CONTRACT.(1)20Amps1120Volt Circuit - Secondary 12VDC Date 113 SOUAW000 LAfIE COLLEGEVILLE, PA 19426 SUITE 103 Electric Draw: 3 Amps 2-16-16 Page 1 of 4 CHARLOTTESVILLE, VA, 22911 APProvetlby Dale Primary Electric Feed Within 3.0" of Sign, by Others T.O. PARAPET 24'-8" A.F.F. D z L -j Q = D.B.E. - m ¢o 7'-6" A.F.F. z _ - � _o M M EASE LINE. CI � w T.O. STOREFRONT 10'-0" A.F.F. T.O. EX. ENTRY DOORS ± 7'-0" A.F.F. FINISHED 0'-0" EQ 3'-3" 16" 13'-2" SIGN '-0" PET VALU LEASED SPACE 11 3'-3" EQ SIGN LEASE LINE. T.O. PARAPET ± 21'-4" A.F.F. IT i i i �If1 PROPOSED STOREFRONT ELEVATION - TOTAL SIGN AREA 47.85 SF Scale: 3/16"=1'-0" 113 SOLIRW000 ME COLLEGEVILLE, PR 19426 PANTOPS SHOPPING CENTER 2040 ABBEY ROAD SUITE 103 CHARLOTTESVILLE, VA, 22911 Starlight National Signs 2014 THIS DRAWING INCLUDES DATA THAT IS PROPRIETARY INFORMATIONOF STARLIGHTNATIONAL SIGNS. IT SHALL NOT BE USED, DUPLICATED OR DISCLOSED IN WHOLE OR PART FOR ANY PURPOSE OTHER THAN TO EVALUATE THIS PROPOSAL.. IF A CONTRACT IS AWARDED TO THIS PROPOSER AS A RESULT OF OR IN CONNECTION WITH THE SUBMISSION OF THIS DATA, THE DEFEREE SHALL HAVE THE RIGHT TO USE OR DISCLOSE THE DATA TO THE EXTENT PROVIDED IN THE RESULTING CONTRACT. App—d by Dale *LISTED Untlerwri[ers Labora[orles, Ing ELECTRICAL REQUIREMENTS (1) 20 Amps1120 Volt Circuit — Secondary 12V DC Electric Draw: 3 Amps Primary Electric Feed Within 3.0" of Sign, by Others PM By VR MG Date 2-16-16 lielp'll Page 2 of 4 In co O co co N CNI N 13'-2"(158" COPY - ------ --------------- INTERNALLY ILLUMINATED LED CHANNEL LETTERS Scale: 1/2"=V-0" Sign Area: 31.275 sf Qty (1) Set Internally Illuminated Remote Led Channel Letters to read "Pet Valu" Faces: 3/16"(thick) #7328 White Acrylic SIGN AREA` CALCULATION ALBEMARLE COUNTY CODE CHAPTER 18 ZONING SECTION 4.15 SIGNS 4.15.11 Wall Signs; Allowed 1.5 sf per 1 If of establishment structure frontage not to exceed 200 square feet 50'-0" x 1.5sf = 75 sf allowed Proposed Sign A: 31.27 sf Proposed Sign B: 16.58 sf Total Sign Area: 47.85 sf NOTE: *THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. Trimca . Painted to match Mathews 313 Dark Bronze PRIMARY Returns: Painted to match Mathews 313 Dark Bronze BY OTHER Illumination: White LEDs I WITHIN 3' 113 SOURWOOD LRnE COLLEGEVILLE, PR 19426 PANTOPS SHOPPING CENTER 2040 ABBEY ROAD SUITE 103 CHARLOTTESVILLE, VA, 22911 Starlight National Signs 2014 THIS DRAWING INCLUDES DATA THAT IS PROPRIETARY INFORMATION OF STARLIGHTNATIONAL SIGNS. IT SHALL NOT BE USED, DUPLICATED OR DISCLOSED IN WHOLE OR PART FOR ANY PURPOSE OTHER THAN TO EVALUATE THIS PROPOSAL.. IF A CONTRACT IS AWARDED TO THIS PROPOSER AS A RESULT OF OR IN CONNECTION WITH THE SUBMISSION OF THIS DATA, THE DEFEREE SHALL HAVE THE RIGHT TO USE OR DISCLOSE THE DATA TO THE EXTENT PROVIDED IN THE RESULTING CONTRACT Approved by Date *LISTED Underwriters Labora[orles, Ing ELECTRICAL REQUIREMENTS (1) 20 Amps1120 Volt Circuit - Secondary 12V DC Electric Draw: 3 Amps Primary Electric Feed Within 3.0" of Sign, by Others ODIRECT MOUNT SECTION DETAIL Scale: 1/2" =1 '-0" APPROPRIATE 3/8" GALVANIZED FASTENERS (TYP. MINIMUM 4 PER LETTER AS REQUIRED) ALUMINUM RETURNS 1 " TRIM -CAP WITH #8 SHEET METAL SCREWS 3/16" ACRYLIC FACE ALUMINUM LETTER BACKS L.E.D. ILLUMINATION DISCONNECT SWITCH LOW VOLTAGE POWER SUPPLY 1/4" DRAIN HOLE EIFS WALL PM By VR MG Date 2-16-16 NOTES: -- PRIMARY ELECTRIC BY OTHERS TO BE WITHIN T-0" OF SIGN (TYP) — CLEAR AND UNOBSTRUCTED ACCESS REQUIRED BEHIND WALL FOR REMOTE/RACEWAY WIRING — ADEQUATE BLOCKING BEHIND WALL REQUIRED BY OTHERS — SIGN WIRING INSTALLED IN FIELD TO MAINTAIN ALL STATE AND LOCAL CODES/ REGULATIONS 1111VAJ1 Page 3 of 4 3'-3" (39") DIAM Copy to be illuminated Opaque Background QTY (2) INTERNALLY ILLUMINATED LED CHANNEL LOGO GRAPHIC Scale: 3/4"=1'-0" Sign Area: 8.29 sf ea Qty (2) 3'-3"(39")(diam) Internally illuminated remote led channel logos Face: 3/16" (thick) #7328 White Acrylic with 1 st surface reverse cut opaque black vinyl with Pantone 2383 Blue vinyl overlay for the "valu" Returns: Painted to match Mathews 313 Dark Bronze Trimca . Black 1 "(thick) Illumination: White LEDs NOTE: GRAPHIC HEIGHT 3'-3"(39"), NOT TO EXCEED THE TALLEST LETTER IN THE SIGN, 3'-3"(39") 113 SOURW000 LRNE COLLEGEVILLE, PR 19426 PANTOPS SHOPPING CENTER 2040 ABBEY ROAD SUITE 103 CHARLOTTESVILLE, VA, 22911 Starlight National Signs 2014 THIS DRAWING INCLUDES DATA THAT IS PROPRIETARY INFORMATIONOF STARLIGHTNATIDNAL SIGNS. IT SHALL NOT BE USED, DUPLICATED OR DISCLOSED IN WHOLE OR PART FOR ANY PURPOSE OTHER THAN TO EVALUATE THIS PROPOSAL.. IF A CONTRACT IS AWARDED TO THIS PROPOSER AS A RESULT OF OR IN CONNECTION WITH THE SUBMISSION OF THIS DATA, THE DEFEREE SHALL HAVE THE RIGHT TO USE OR DISCLOSE THE DATA TO THE EXTENT PROVIDED IN THE RESULTING CONTRACT. App—d by Dale *LISTED Untlerwri[ers Labora[orles, Ing ELECTRICAL REQUIREMENTS (1) 20 Amps1120 Volt Circuit — Secondary 12V DC Electric Draw: 3 Amps Primary Electric Feed Within 3.0" of Sign, by Others NOTE: *THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. PRIMARY BY OTHER WITHIN 3' ®DIRECT MOUNT SECTION DETAIL Scale: 1/2" =1 '-0" APPROPRIATE 3/8" GALVANIZED FASTENERS (TYP. MINIMUM 4 PER LETTER AS REQUIRED) ALUMINUM RETURNS 1" TRIM -CAP WITH #8 SHEET METAL SCREWS 3/16" ACRYLIC FACE ALUMINUM LETTER BACKS L.E.D. ILLUMINATION DISCONNECT SWITCH LOW VOLTAGE POWER SUPPLY 1/4" DRAIN HOLE BRICK WALL PM By VR MG Date 2-16-16 NOTES:- - PRIMARY ELECTRIC BY OTHERS TO BE WITHIN 3'-0' OF SIGN (TYP) -- CLEAR AND UNOBSTRUCTED ACCESS REQUIRED BEHIND WALL FOR REMOTE/RACEWAY WIRING — ADEQUATE BLOCKING BEHIND WALL REQUIRED BY OTHERS — SIGN WIRING INSTALLED IN FIELD TO MAINTAIN ALL STATE AND LOCAL CODES/ REGULATIONS 1111VAJI Page 4 of 4