HomeMy WebLinkAboutARB201600022 Review Comments Final Site Plan and Comps. 2016-05-31COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 May 31, 2016 Scott Collins /Collins Engineering 200 Garrett St., Ste. K Charlottesville, Va. 22902 RE: ARE-2016-22: Sunset Overlook Dear Mr. Collins, The Albemarle County Architectural Review Board reviewed the above noted item at its meeting on Friday, April 1, 2016. The Board, by a vote of 3:0, approved the request, pending staff administrative approval of the conditions listed below. A plan with the revision date of 5116/16 has been submitted. Updated comments are provided within the underlined text below. Identify existing individual large shade, evergreen and omamental trees to remain on the plan by size and species to show that the minimum EC frontage tree requirement can be met. If the requirement can't be met, show additional new trees to be planted to meet the requirement. Rev. 1: Comment not fully addressed. Include a table for preserved trees that are to meet the EC fronts - a tree re uirement. The table should specify the tree symbol ex. QP) used in the plan, the botanical name, the common name, the quantity and the trees should be categorized by tree type (ex. large shade trees, ornamental trees, evergreen trees, etc). Label each preserved tree utilized to meet the EC frontage tree re uirments with treesymbol and size. Trees within Lot g or Lot 10 can not count toward this requirement. Move trees to be within the open space if they are to be part of the EC frontage tree calculation. 2. If the existing trees within the open space along Rt. 631 are meant to be preserved add a note specifying that. Rev. 1: When using preserved trees to meet the EC frontage tree requirement preservation methods need to be utilized. Accurately represent the driplines of any existinq tree being included in the calculation for the EC frontage tree requirement. Grading and the limits of clearing and grading are shown within the dripline of some of the trees that seem to be specified as being preserved. Preservation methods are required when grade changes would otherwise impact the area within their dripline. Tree wells are needed when the ground would otherwise be raised and tree walls are needed when ground would otherwise be lowered, within the dripline of a preserved tree. If tree wells or tree walls are to be utilized to preserve trees_ provide the required details for the tree well and/or tree walls. Page 1 of 3 3. Adjust the tree protection fencing and/or the existing tree line so that they accurately represent the extents of the retained existing wooded area. Rev. 1: Comment Addressed. 4. Modify the mechanical notes to state that the HVAC unit will be "... located in the north side yard of the house or at the rear of the house screened or enclosed with a fence or landscaping." Rev. 1: Comment Addressed. 5. Confirm there are no utilities or utility easements between the existing pedestrian trail and lots 9 and 10. Show any utilities or easements if they exist. Rev. 1: Comment Addressed. 6. Include a landscape calculation for the street trees along the interior streets and along Sunset Avenue Extended. Rev. 1: Comment not fully addressed. Modify landscaping note #3 to specify that the calculation is for "interior' street trees. Modify the required tree counts in the notes by the streets so that they match the number of required trees in note #3. 7. Add at least one medium shade trees along the proposed pedestrian path in the open space area between the existing wooded area and the cul-de-sac and lots 9 and 10. Rev. 1: Comment Addressed. 8. Design the pedestrian connector to the asphalt path to minimize its impact on the buffer and existing landscape. Show details for any stairs and railings that are required for the proposed pedestrian path. Rev. 1: Consider revising the design of the stairs and railings for the pedestrian connection to Old LynchburgLynchbung Road to utilize materials that would reduce future maintenance requirements and issues. 9. Show the tree protection fencing on the grading and erosion and sediment control sheets. Rev. 1: Comment Addressed. 10. Add a mix of native plantings or maintain existing plant material to ensure a screen of the southwest corner of the development from the EC. Rev. 1: Move the proposed pin oak to be fully within the open space and not on the edge of the Lot 10 property line. Trees within Lot 10 cannot be counted towards this requirement. 11. Move the Limits of Clearing and Grading and Tree Protection Fencing note for the wooded area along the EC so that it points at the protective fencing. If the limits and the fencing are not in the same place clarify the notes and lines. Rev. 1: Comment Addressed. If you have any questions, please do not hesitate to contact me. Sincerey, P-a Satern Cc: Forge Farm LLC 195 Riverbend Drive Charlottesville Va 22911 File Page 2 of 3 COUNTY OF ALBEMARLE Department of Community Development REVISED APPLICATION SUBMITTAL This form must be returned with your revisions to ensure proper tracking and distribution. County staff has indicated below what they think will be required as a resubmission of revisions. If you need to submit additional information please explain on this form for the benefit of the intake staff. All plans must be collated and folded to fit into legal size files, in order to be accepted for submittal, TO: Paty Saternye DATE: PROJECT NAME: ARB-2016-22: Sunset Overlook Final Site Plan Submittal Type Requiring Revisions t 1 indicates submittal code County Project Number # Copies Erosion & Sediment Control Plan (E&S) Mitigation Plan (MP) Waiver Request (WR) Stormwater Management Plan (SWMP) Road Plan (RP) Private Road Request, with private/public comparison RR Private Road Request — Development Area RR-DA Preliminary Site Plan SP Final Site Plan or amendment FSP Final Plat P Prelimin Plat PP Easement Plat EP Boundary Adjustment Plat (BAP) Rezoning Plan (REZ) Special Use Permit Concept Plan (SP-CP) Reduced Concept Plan (R-CP) Proffers ) Bond Estimate Request ER Draft Groundwater Management Plan -GWMP) Final Groundwater Management Plan F-GWMP) Aquifer Testing Work Plan (ATWP Groundwater Assessment Report (GWAR) Architectural Review Board (ARB) ARB2016-22 Other: Please explain (For staff use only) Submittal Code # Copies Distribute To: Submittal Code # Copies Distribute To: ARB 2 Paty Saternye Page 3 of 3