RE: ARB201600009 Texas Roadhouse
Dear Paula,
have reviewed your site plan with revision date of 5-27-16 for the above -referenced project. My comments are listed below.
1. Previous comment: Provide the light fixture out sheets and photometric plan as a part of the site plan set.
The photometric plan and cut sheet for the parking lot fixtures were included in the site plan. However, the cut sheets
for the wall fixtures were not included in the plan. Provide all fight fixture cut sheets as part of the site plan set.
2. Previous comment: Lighting spillover exceeds .5 footcandles at the property line along Rt. 29. Revise the photometric
plan to eliminate spillover in excess.of .5 fc.
Spillover was eliminated, but the LLF for Fixture B was reduced to .9. Spillover in excess of .5 fc at the property line
along Rt. 29 must be eliminated and the LLF for all fixtures must equal 1.0. Revise the lighting plan to eliminate
spillover in excess of .5 fc. at the proprety line along Rt. 29 and to calculate the photometrics using an LLF of
1.0 for all fixtures.
3. Previous comment: Indicate for review the color of the retaining wall and provide this information on the plan.
I was not able to find information on the color of the retaining wall. Please indicate for review the color of the
retaining wall and provide this information on the plan. If the information was already provided, please indicate the
location within the plan where it can be found.
Please provide:
1. One set of revised drawings addressing each of these conditions. Include updated revision dates on each drawing.
2. A memo including detailed responses indicating how each condition has been satisfied. If changes other than those
requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with
"clouding" or by other means will facilitate review and approval.
3. The attached "Revised Application Submittal" form. This form must be returned with your revisions to ensure proper
tracking and distribution.
When staffs review of this information indicates that all conditions of approval have been met, a Certificate of Appropriateness
may be issued. If you have any questions, please do not hesitate to contact me.