Loading...
HomeMy WebLinkAboutSDP201600018 Review Comments Initial Site Plan 2016-10-12Short Review Comments Report for: SDP201600018 SubApplication Type: Better Living Berkmar - Initial Initial Site Plan Date Completed:05/02/2016 Reviewer:Christopher Perez CDD Planning Review Status:Requested Changes Reviews Comments: Division: Date Completed:04/05/2016 Reviewer:Andrew Slack CDD E911 Review Status:No Objection Reviews Comments:No objection. Division: Date Completed:05/04/2016 Reviewer:Joel DeNunzio VDOT Review Status:Requested Changes Reviews Comments: Division: Date Completed:05/03/2016 Reviewer:Robbie Gilmer Fire Rescue Review Status:Requested Changes Reviews Comments:Based on plans dated 3/21/16. 1. Please add a note to the plans " Knox Box required, please contact Albemarle County Fire Marshal office for location" 2. Fire Flow test required before final approval. 3. Hydrant spacing shall be a maximum of 400' per travel way. Please add a hydrant to the larger island as you enter the loading & Storage area. 4. FDC shall be located on the address side of the structure. 5. FDC shall have a hydrant with 100' per travel way. This will require a second hydrant located on Berkmar at the entrance. 6. Structures over 30' in height require aerial truck access of 26' clear travel way. Please increase the travel way in the east parking lot to 26'. The travel lane to the north of the structure is already 26', but it shows a grade of 10% and our aerial trucks can only overcome 8% front to back. Division: Date Completed:05/02/2016 Reviewer:Alexander Morrison ACSA Review Status:Requested Changes Reviews Comments: From: Alexander Morrison [mailto:amorrison@serviceauthority.org] Sent: Monday, May 02, 2016 3:30 PM To: Christopher Perez <cperez@albemarle.org> Subject: SDP201600018: Better Living Berkmar - Initial Site Plan Chris, I have reviewed the above referenced application and have the following comments: • Construction submittal to the ACSA will be required at the final site plan stage. Submit 3 copies of the plan along with water and sewer data sheets to the ACSA, Attn: Michael Vieira, PE. • RWSA review and approval of the water connection is required. • 2 fire hydrants will be required to meet the fire code. Per Fire/ Rescue, one shall be placed in the large island in the parking lot and the second shall be placed on the address side of Building A. • During the construction review the ACSA will determine the what sections of the proposed sewer will be public. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (O) 434-977-4511 Ext. 116 (C) 434-981-5577 (F) 434-979-0698 Division: Page:1 of 4 County of Albemarle Printed On:March 21, 2017 • Construction submittal to the ACSA will be required at the final site plan stage. Submit 3 copies of the plan along with water and sewer data sheets to the ACSA, Attn: Michael Vieira, PE. • RWSA review and approval of the water connection is required. • 2 fire hydrants will be required to meet the fire code. Per Fire/ Rescue, one shall be placed in the large island in the parking lot and the second shall be placed on the address side of Building A. • During the construction review the ACSA will determine the what sections of the proposed sewer will be public. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (O) 434-977-4511 Ext. 116 (C) 434-981-5577 (F) 434-979-0698 Date Completed:05/05/2016 Reviewer:Patricia Saternye CDD ARB Review Status:Requested Changes Reviews Comments:The Better Living Initial Site Plan is scheduled for the May 16, 2016 ARB meeting. The ARB Staff Report can be accessed under ARB201600039 in County View. Division: Date Completed:04/20/2016 Reviewer:Jay Schlothauer CDD Inspections Review Status:Requested Changes Reviews Comments:Based on plans dated March 21, 2016. Based on the total number of parking spaces (79), a total of four barrier-free parking spaces are required. Provide two more barrier-free parking spaces, with associated striped access aisle and curb cut. Division: Date Completed:04/25/2016 Reviewer:Matthew Wentland CDD Engineering Review Status:See Recommendations Reviews Comments:Based on plans dated 03-21-2016: 1. A WPO submittal will be required containing ESC and SWM plans and a SWPPP [17-300, 17-301]. 2. In managed slopes, the maximum retaining wall height is 6' with a minimum 3' separation between tiered walls [18.30.7.5(a)]. 3. Provide a barrier/guardrail where retaining walls are next to travelways. 4. Provide gutters where necessary to control or direct stormwater runoff [18.4.12.15(g)]. Division: Date Completed:08/03/2016 Reviewer:Christopher Perez CDD Planning Review Status:Requested Changes Reviews Comments: Division: Date Completed:06/23/2016 Reviewer:Andrew Slack CDD E911 Review Status:No Objection Reviews Comments:No Objection. Division: Date Completed:07/08/2016 Reviewer:Matthew Wentland CDD Engineering Review Status:See Recommendations Based on plans dated 06-13-2016, the following comments should be addressed on the final site plan and the VSMP plan: 1. A WPO submittal will be required containing ESC and SWM plans and a SWPPP [17-300, 17-301]. 2. Provide a barrier/guardrail where retaining walls are next to travelways. 3. Provide curb & gutter where necessary to control or direct stormwater runoff [18.4.12.15(g)]. 4. The County recommends acquiring temporary easements when work takes place within 5' of the propery line. 5. The condition and adequacy of the existing storm sewer may need to be verified for the VSMP submittal. 6. The runoff south of Buildings C & D may need to be directed to an adequate channel or converted to sheet flow. Division: Page:2 of 4 County of Albemarle Printed On:March 21, 2017 Reviews Comments:Based on plans dated 06-13-2016, the following comments should be addressed on the final site plan and the VSMP plan: 1. A WPO submittal will be required containing ESC and SWM plans and a SWPPP [17-300, 17-301]. 2. Provide a barrier/guardrail where retaining walls are next to travelways. 3. Provide curb & gutter where necessary to control or direct stormwater runoff [18.4.12.15(g)]. 4. The County recommends acquiring temporary easements when work takes place within 5' of the propery line. 5. The condition and adequacy of the existing storm sewer may need to be verified for the VSMP submittal. 6. The runoff south of Buildings C & D may need to be directed to an adequate channel or converted to sheet flow. Date Completed:06/20/2016 Reviewer:Jay Schlothauer CDD Inspections Review Status:No Objection Reviews Comments:Based on plans revised June 13, 2016. No further comments or conditions. Division: Date Completed:07/18/2016 Reviewer:Adam Moore VDOT Review Status:Requested Changes Reviews Comments: Division: Date Completed:07/11/2016 Reviewer:Robbie Gilmer Fire Rescue Review Status:Requested Changes Reviews Comments:Based on plans dated 6/13/16. 1. Please add a note to the plans " Knox Box required, please contact Albemarle County Fire Marshal office for location" 2. Fire Flow test required before final approval. 3. Hydrant spacing shall be a maximum of 400' per travel way. Please add a hydrant to the larger island as you enter the loading & Storage area. 4. FDC shall be located on the address side of the structure. 5. FDC shall have a hydrant with 100' per travel way. This will require a second hydrant located on Berkmar at the entrance. 6. Structures over 30' in height require aerial truck access of 26' clear travel way. Please increase the travel way in the east parking lot to 26'. The travel lane to the north of the structure is already 26', but it shows a grade of 10% and our aerial trucks can only over come 8% front to back. Division: Date Completed:07/25/2016 Reviewer:Alexander Morrison ACSA Review Status:No Objection Reviews Comments: Division: Date Completed:07/11/2016 Reviewer:Patricia Saternye CDD ARB Review Status:See Recommendations Reviews Comments:The Better Living Initial Site Plan is scheduled for the August 1, 2016 ARB meeting. The ARB Staff Report will be able to be accessed under ARB201600039 in County View on or before the ARB meeting date. Division: Date Completed:08/19/2016 Ron HigginsPage:3 of 4 County of Albemarle Printed On:March 21, 2017 Reviewer:Ron Higgins CDD Zoning Review Status:No Objection Reviews Comments: Division: Date Completed:09/23/2016 Reviewer:Christopher Perez CDD Zoning Review Status:No Objection Reviews Comments: Division: Date Completed:09/13/2016 Reviewer:Adam Moore VDOT Review Status:Requested Changes Reviews Comments:From: Christopher Perez Sent: Wednesday, September 14, 2016 7:33 AM To: 'Justin Shimp, P.E.' <justin@shimp-engineering.com> Cc: 'Moore, Adam PE (VDOT)' <Adam.Moore@vdot.virginia.gov> Subject: SDP201600018 Better Living Berkmar - Initial Site Plan Justin, SDP201600018 Better Living Berkmar - Initial Site Plan It appears that Adam Moore of VDOT has been trying to contact you to discuss their July 18, 2016 comments, specifically the shared access comment #5. They have been unable to get ahold of you for this conversation but have had a couple discussions with me about this comment. They have also had discussions with Rachel Falkenstein about this item as well. She is the reviewer for the rezoning for Wood/Von Storch (ZMA2016-9) located on TMP 45-112E, to which a similar comment was provided to her on the rezoning. After some discussions w/ Adam about what the comment actually means and whether or not it was a requirement or a recommendation, he has issued a revised comment letter, see attached. This comment letter has also been uploaded to Countyview. Notably this does not appear to interfere with the special exceptions moving forward on the Oct 12th agenda; rather, it seems to actually add to the justification for approval. Christopher P. Perez | Senior Planner Department of Community Development |County of Albemarle, Virginia 401 McIntire Road | Charlottesville, VA 22902 434.296.5832 ext. 3443 Division: Date Completed:09/27/2016 Reviewer:Patricia Saternye CDD ARB Review Status:No Objection Reviews Comments: Division: Date Completed:09/28/2016 Reviewer:Christopher Perez CDD Planning Review Status:Requested Changes Reviews Comments:Initial site plan has been approved w/ conditions 9-28-16 Division: Date Completed:10/12/2016 Reviewer:Christopher Perez CDD Planning Review Status:Approved Reviews Comments: Division: Page:4 of 4 County of Albemarle Printed On:March 21, 2017 A4,cf t.,1 '41IinOf R V�RGII3�p COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,North Wing Charlottesville,Virginia 22902-4596 Phone(434)296-5832 Fax(434)972-4126 September 28,2016 Justin Shimp,Shimp Engineering 201 E.Main Street, Suite M Charlottesville VA 22902 SDP201600018 Better Living Berkmar-Initial Site Plan Mr. Shimp, The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan. This approval shall be valid for a period of five(5)years from the date of this letter,provided that the developer submits a final site plan for all or a portion of the site within one(1)year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle,and thereafter diligently pursues approval of the final site plan. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. ARB conditions to be satisfied prior to issuance of a grading permit: "If existing trees are to be utilized for screening or any other EC requirements label them as preserved',provide tree protection fencing and speck the individual tree locations, canopy limits, caliper and species." 2. Submittal of a tree conservation checklist with areas for tree preservation identified. 3. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. 4. Approval of all easements for facilities for stormwater management and drainage control. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. A fee of$1,613. Please submit 10 copies of the final plans to the Community Development Department.The assigned Lead Reviewer will then distribute the plans to all reviewing agencies.Once you receive the first set of comments on the final site plan,please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members: Albemarle County Planning Services(Planner)-3 copies [Christopher Perez ext 3443] Albemarle County Planning Services(ARB)- 1 copy[Paty Saternye ext. 3250] Albemarle County Engineering Services(Engineer)- 1 copy[Matthew Wentland ext 3458] Albemarle County Information Services(E911)- 1 copy[Andrew Slack ext 3384] Albemarle County Department of Fire Rescue- 1 copy[Robbie Gilmer 434-296-5833] Virginia Department of Transportation- 1 copy[Adam Moore 434-422-9894] Albemarle County Building inspections— 1 copy[Jay Schlothauer ext 3228] Albemarle County Service Authority(ACSA)- 1 copy[Alex Morrison 434-977-4511 ext 116] If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3443,cperez@albemarle.org. Smcerel Senior Planner 1 New, F A �'IRGIISP County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville,VA,22902 Phone 434-296-5832 Fax 434-972-4126 Memorandum To: Justin Shimp From: Christopher P.Perez,Senior Planner Division: Planning Date: September 28,2016 Subject: SDP201600018 Better Living Berkmar-Initial Site Plan The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed(The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference,which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. A site plan meeting all the requirements of section 32.6 of Chapter 18 of the Code. 2. [32.7.2.1] Vehicular access to site. Each entrance onto any public street shall be designed and constructed as required by the standards of the Virginia Department of Transportation(VDOT).VDOT approval of the entrance to the site shall be required prior to final site plan approval(see attached Sept 13,2016 VDOT comments). [21.7,4.20(a)2]Front-maximum setbacks. Building'A' does not meet the maximum 30 foot front setback from Berkmar Drive.The applicant has requested a special exception(SE)to this requirement of the ordinance.Prior to final site plan approval the applicant shall receive approval of the SE by the Board of Supervisors(BOS)or redesign the site to meet the maximum front setback. This item is scheduled for the Oct 12, 2016 BOS meeting.If approved on sheet 1 list all special exceptions that were approved along with the date of approval. Cylwitrei re. - ve [21.7,4.20(a)3] Side setback. Storage Shed D is located closer than 50 feet from the adjacent residentially zoned properties of TMP 45-112&45-112E.Also,there are 18 proposed parking spaces located closer than 20 feet to these residentially zoned parcels.The applicant has requested a SE to the side setback requirement of the ordinance.Prior to final site plan approval the applicant shall receive approval of the SE by the BOS or redesign the site to meet the side setbacks. This item is scheduled for the Oct 12, 2016 BOS meeting.If approved on sheet 1 list all special exceptions that were approved along with the date of approval. (AIN fkotka f o-i;--/6 /. [21.7(c)]Buffer zone adjacent to residential districts. Improvements(18 parking spaces,grading,retaining walls,and street tree plantings)are proposed within the 20 foot undisturbed buffer between the residentially zoned parcels of TMP 45-112&45-112E and the site.The applicant has requested a SE to the buffer requirement of the ordinance. Prior to final site plan approval the applicant shall receive approval of the SE by the BOS or redesign the site to meet the buffer requirements. This item is scheduled for the Oct 12, 2016 BOS meeting. If approved on sheet 1 list all special exceptions that were approved along with the date of approval. Reid /6-0-4 6. [32.5.2(a),4.2.1,4.2.2(b)] General information. Portions of this development are proposed on TMP 45-68C1 (0.16 acres)and TMP 45-112A(0.715 acres),which rely on a boundary line adjustment(BLA)with these properties.Prior to final site plan approval the lot line adjustments shall take place on a subdivision plat to be reviewed by the County, approved,and then recorded in the Clerk's Office.The DB page information of this action shall be provided on the final site plan. 7. [32.5.2(k),32.7.5.1,4.1] Water and sewer facilities. As part of the BLA of TMP 45-112A the reduced parcel will be reviewed to assure it contains adequate sewer and water services onsite. If the existing home is without either of these, it shall be required to connect to public water and/or public sewer as it is located in the jurisdictional area of the County.In order to not connect to both of these,the applicant shall provide a completed application for an exemption. Prior to BLA approval,the exemption shall be reviewed and a finding shall be made to either approve or deny the 1 request.If the request is denied then public water and sewer shall be provided onsite and ACSA shall review/approve this aspect of the proposal.If the exemption request is approved to not provide public sewer and/or public water,the Health Department will be required to review/approve the BLA to assure adequate septic&water systems are provided onsite. 8. [32.5.2(i)]Easements. Improvements are proposed within the existing publically dedicated access easement(DB 1429 PG 122).The applicant proposes to relocate the easement in a New 15' VDOT access easement as depicted on TMP 04500-00-00-068C1.The easement shall be platted prior to final site plan approval.The plat shall be reviewed by the County&VDOT,approved,and then recorded in the Clerk's Office,the DB page information of this action shall be provided on the final site plan. 9. 132.5.1(c)] As proposed offsite grading is taking place on TMP 45-68C1 and TMP 45-68A.All offsite grading easements shall be applied for/reviewed/approved/recorded prior to final site plan approval. 10. [32.5.2(k)]Proposed sewer&water facilities. The proposed sanitary sewer line is located on TMP 45-68C1 and 45- 68A.The final site plan shall depict the entire extent of this easement on these properties from where the line originates along Route 29 to where it connects to Building A.Also,the proposed water connection for this site is located on TMP 45-112E.All offsite water and sewer easements shall be reviewed by the County,approved,and then recorded in the Clerk's Office prior to final site plan approval.The DB page information of this action shall be provided on the final site plan. 11. [32.5.2(j)]Existing sewer and drainage facilities. Label,dimension,and depict the existing and proposed water and sewer facilities and easements. 12. [32.7.2.3]Sidewalks and other pedestrian walkways. Are customers permitted within Building C?If so,it is suggested the applicant provide pedestrians a safe and convenient walkway/marked path from the parking area to the building. 13. [32.5.2(b)]Proposed use. Some aspects of the proposal which are depicted on the initial site plan do not match what is proposed/depicted on the ARB submission and vice-versa.For example: 1)the extent of the screening fence along the northern property line 2)evergreen screening along the northern property line(25 plantings of eastern arborvitae&4 plantings of pin oaks). Prior to final site plan approval the differences between the two plans shall be rectified and properly depicted on the final site plan. 14. [4.12.15(g)] Curb and Gutter. Provide curb and gutter in the parking area and along the travelways. 15. [32.5.2(a)] General Information. Throughout the plan depict the zoning and the current uses of all abutting parcels (specifically the residentially zoned properties TMP 45-112&45-112E). 16. [32.5.2(n)]Existing and proposed improvements. If there is to be a sign for the proposed use,on the final site plan depict and label the sign location. (Depicting the sign on the final site plan is not approval of the sign location or type). 17. [32.5.2(a)] Approval from the ARB is required prior to final site plan approval.See attached ARB review comments. 18. [Comment] The screening fence is blocking access to the stormwater treatment area.For maintenance purposes assure there is a way to access this area of the site. 19. [32.5.2(n)&(p)]The following will be required for final site plan approval: - Outdoor lighting information including a photometric plan and location,description,and photograph or diagram of each type of outdoor luminaire[Sec.32.7.8&Sec.4.17] - A complete landscape plan in accordance with[Sec. 32.7.9] Please contact Christopher P.Perez in the Planning Division by using cperez(c//albemarle.org or 434-296-5832 ext. 3443 for further information. 2 Phone 434-296-5832 County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 Memorandum Fax 434-972-4126 To: Christopher Perez From: Paty Saternye, Senior Planner Division: ARB Date: September 27, 2016 Subject: SDP201500039 Better Living — Initial Site Plan I have reviewed the revised Initial Site Plan submittal against the requirements and recommendations approved by the Architectural Review Board on August 15, 2016, and offer the following comments: Prior to Initial Plan approval 1. Revise the plan to clearly show the limits of the "Loading & Storage Area", with hatching or other method. If the storage area extends to the north side of "Building B Open Shed" provide additional screening along the north side of the parcel to eliminate visibility of this area, or submit an application for a special use permit. Revl : Comment Addressed. Limits of the loading and storage area have been shown as dashed lines with labels. 2. Screening of the storage area may be provided by walls, plantings or fencing, or a combination of these. When accomplished by new vegetation, do not provide the screening in rigid rows. Instead provide a less formal layout and include multiple species to blend with the surrounding area. At a minimum provide evergreen shrubs 24" at planting along the chain link fence adjacent to the stormwater management area. Revl : Comment Addressed. Screening is being accomplished with buildings and a 16' tall concrete wall. 3. If existing trees are to be utilized for screening or any other EC requirements label them as `preserved', provide tree protection fencing and specify the individual tree locations, canopy limits, caliper and species. Rev1: Comment Addressed. No existing trees are being utilized for screening and therefore do not need to be preserved. 4. Expand the wording of the note under "Proposed Use" on the coversheet to say, "Items stored within the outdoor storage area shall not exceed the height of the landscaping, or other methods of screening installed, and shall not be visible from the Entrance Corridor." Rev1: Comment Addressed. The note has been revised. 5. Indicate on the plan the walls of the buildings and sheds that will be open. Rev1: Comment Addressed. Labels have been provided specifying which sides of the sheds are open. 6. If existing trees to remain are not to be "preserved" then do not include them in any EC required landscaping. Revl : Comment Addressed. No existing trees are being utilized to meet EC required landscaping and therefore o not need to be preserved. Please contactPat er�ye in the Planning Division by using psaternye(a�albemarle.org or 434-296-5832 ext. 3250 for further inf r atifin. PROJECT MA GEMENT SElimp CIVIL ENGINEERING LAND PLANNING ENGINEERINGW.; September 26, 2016 Paty Saternye Albemarle County Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Regarding: SDP201600018—Better Living-Berkmar Dear Paty, Thank you for your review of the Initial Site Plan for Better Living-Berkmar.We have reviewed and revised the plan per your comments dated August 19,2016. See below for detailed responses to each of the comments. 1. The plan has been revised to clearly show the limits of the"Loading and Storage Area". Additional screening has been added along the north side of the parcel to eliminate visibility of this area. 2. Screening of the storage area has been provided as requested. 3. No existing trees are being used to meet the screening or any other EC requirement. 4. The note under"Proposed Use"has been revised as requested. 5. Each building and shed has been labeled to indicate the location of open walls, if any. 6. No existing trees are being used to meet any EC requirement. If you have any questions or concerns about these revisions please feel free to call me at (434)227-5140 and we can discuss any questions that you may have in further detail. -5 Reg- S Ju yn Shimp, 7,1. imp Engineering, P.C. Charles A. Kilpatrick, P.E. Commissioner COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper. Virginia 22701 September 13, 2016 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Christopher Perez Re: Better Living Berkmar Drive- Initial site plan SDP -2016-00018 Review #2 REVISED Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Shimp Engineering, dated March 6, 2016, with a revision date of June 13, 2016 and offers the following comments: Land Use 1. Please provide sight distance lines on the plans as well as the landscape plan sheet. Additionally please provide a sight distance profile on the plans. 2. Please see Road Design Manual appendix F -Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Provide a right turn lane warrant analysis as shown in F-96. Please refer to F-109 to provide the appropriate design vehicle and turning radius by land use. 3. Please conform to the pavement widening WP -2, 302_02 in the 2008 Road and Bridge standards. 4. Please provide Route number, Street name, Speed limit, and Right of Way width on all plan sheets. 5. Virginia Code 24VAC30-70-120 requires commercial entrances be shared with only limited exceptions. The applicant shall arrange to share a commercial entrance with the neighboring parcel owned by the Wood/Von Storch partnership and prepare for this entrance to be the sole access point for both properties. One acceptable arrangement would be to provide an access easement to the property line to allow access to the neighboring parcel through the currently proposed layout. Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B (1) and F, as well as any other applicable standards, regulations, or other requirements. September 13, 2016 Mr. Perez Page Two Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process Sincerely, 4" 9. 4V4-� Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Alf0101 Nilo" o COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,North Wing Charlottesville, Virginia 22902-4596 Phone(434)296-5832 Fax(434) 972-4126 August 19, 2016 • Justin Shimp/Shimp Engineering 201 East Main Street, Ste M Charlottesville VA 22906 RE: ARB201600039 Better Living—Berkmar Dear Mr. Shimp, At its meeting on Monday, August 15, 2016, the Albemarle County Architectural Review Board, by a vote of 3:0 voted to forward the following recommendations on the above-noted Initial Site Development Plan to the agent for the Site Review Committee: • Regarding requirements to satisfy the design guidelines as per§ 18-30.6.4(2), (3)and(5): A Certificate of Appropriateness is required prior to final site plan approval. 1. Revise the plan to clearly show the limits of the"Loading& Storage Area",with hatching or other method. If the storage area extends to the north side of`Building B Open Shed" provide additional screening along the north side of the parcel to eliminate visibility of this area. 2. Screening of the storage area may be provided by walls, plantings or fencing, or a combination of these. When accomplished by new vegetation, do not provide the screening in rigid rows. Instead provide a less formal layout and include multiple species to blend with the surrounding area. At a minimum provide evergreen shrubs 24"at planting along the chain link fence adjacent to the stormwater management area. 3. If existing trees are to be utilized for screening or any other EC requirements label them as `preserved', provide tree protection fencing and specify the individual tree locations, canopy limits,caliper and species. 4. Expand the wording of the note under"Proposed Use"on the coversheet to say, "Items stored within the outdoor storage area shall not exceed the height of the landscaping, or other methods of screening installed, and shall not be visible from the Entrance Corridor." 5. Indicate on the plan the walls of the buildings and sheds that will be open. 6. Eliminate visibility of any mechanical equipment from the EC. Specify the location of mechanical equipment, and method of screening utilized for them, on the site plan. 7. Add the standard mechanical equipment note to the architectural plans. 8. Provide details on how the"Roll Off Dumpster"will be screened from the EC or specify in the site plan that the"Roll Off Dumpster" will be kept within the designated "Loading and Storage Areas"at all times. 9. Label the stormwater pond that is located east of"Storage Shed E". 10. Provide landscaping to integrate the stormwater areas, on the east and west sides of "Storage Shed E", into the landscape. 11. Provide proposed topographical information for the "Proposed Storm Water Treatment Area"at the northeast corner of"Building C". 12. Provide evergreen shrubs 24"minimum at planting along the north side of the northern travelway. Update the landscaping calculations to reflect the additional shrubs. 13. Consider providing native plants on the proposed graded slope. 14. Add plants on the terraced retaining walls. 15. Modify the label on the retaining wall to be "James River"color. 16. Provide a material &color sample for this type of retaining wall. 17. If existing trees to remain are not to be"preserved"then do not include them in any EC required landscaping. • Regarding recommendations on the plan as it relates to the guidelines: None „c-N • Regarding recommended conditions of initial plan approval: Prior to Initial Plan approval 1. Revise the plan to clearly show the limits of the"Loading& Storage Area", with hatching c4 or other method. If the storage area extends to the north side of"Building B Open Shed" provide additional screening along the north side of the parcel to eliminate visibility of this area, or submit an application for a special use permit. 2. Screening of the storage area may be provided by walls, plantings or fencing, or a combination of these. When accomplished by new vegetation, do not provide the screening in rigid rows. Instead provide a less formal layout and include multiple species to blend with the surrounding area. At a minimum provide evergreen shrubs 24"at planting along the chain link fence adjacent to the stormwater management area. 4 3. If existing trees are to be utilized for screening or any other EC requirements label them as `preserved', provide tree protection fencing and specify the individual tree locations, a y, canopy limits, caliper and species. F4. Expand the wording of the note under"Proposed Use"on the coversheet to say, "Items stored within the outdoor storage area shall not exceed the height of the landscaping,or other methods of screening installed, and shall not be visible from the Entrance Corridor." 5. Indicate on the plan the walls of the buildings and sheds that will be open. 6. If existing trees to remain are not to be"preserved"then do not include them in any EC required landscaping. • Regarding conditions to be satisfied prior to issuance of a grading permit: If existing trees are to be utilized for screening or any other EC requirements label them as `preserved', provide tree protection fencing and specify the individual tree locations, canopy limits, caliper and species. You may submit your application for continued ARB review at your earliest convenience.Application forms, checklists and schedules are available on-line at www.albemarle.org/ARB. Please be certain that your ARB submittal addresses the above-noted issues. If you have any questions concerning any of the above, please feel free to call me. Sincerely, Patricia SLLaterny ✓✓00 Senior Plann cc: B Properties PO BOX 7627 Charlottesville VA 22906 Phone 434-296-5832 County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 Memorandum Fax 434-972-4126 To: Justin Shimp From: Christopher P. Perez, Senior Planner Division: Planning Date: August 3, 2016 Subject: SDP201600018 Better Living Berkmar - Initial Site Plan The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [Comment] Pay the public notification fee of $215 prior to any further review/action of the plan. 2. [32.5.2(p), 32.7.9.2(b), 30.6.31 Proposed use. Pursuant to Section 30.6.3, Outdoor Storage located in and visible from the Entrance Corridor (EC) requires a Special Use Permit (SP). If the outdoor storage is completely screened and is determined by the Architectural Review Board (ARB) not to be visible from the EC, then a SP is not required. If ARB determines it to be visible from the EC then a SP shall be required prior to approval of the initial site plan. Based on the above, address all ARB comments required for them to verify the storage yard will not be visibility from the EC. The August 1St ARB meeting was canceled because they did not have a quorum of representatives. Once the meeting is rescheduled please attend that meeting. 3. [21.7, 4.20(a)21 Front -maximum setbacks. Building `A' does not meet the maximum 30 foot front setback from Berkmar Drive. The applicant has requested a special exception (SE) to this requirement of the ordinance. Prior to final site plan approval the applicant shall receive approval of the SE by the Board of Supervisors (BOS) or redesign the site to meet the maximum front setback. 4. 121.7, 4.20(a)3] Side setback. Storage Shed D is located closer than 50 feet from the adjacent residentially zoned properties of TMP 45-112 & 45-112E. Also, there are 18 proposed parking spaces located closer than 20 feet to these residentially zoned parcels. The applicant has requested a SE to the side setback requirement of the ordinance. Prior to final site plan approval the applicant shall receive approval of the SE by the BOS or redesign the site to meet the side setbacks. 5. [21.7(c)] Buffer zone adjacent to residential districts. Improvements (18 parking spaces, grading, retaining walls, and street tree plantings) are proposed within the 20 foot undisturbed buffer between the residentially zoned parcels of TMP 45-112 & 45-112E and the site. The applicant has requested a SE to the buffer requirement of the ordinance. Prior to final site plan approval the applicant shall receive approval of the SE by the BOS or redesign the site to meet the buffer requirements. 6. [32.7.2.1] Vehicular access to site. Each entrance onto any public street shall be designed and constructed as required by the standards of the Virginia Department of Transportation (VDOT). VDOT approval of the entrance to the site shall be required prior to final site plan approval. VDOT's July 18t' comment #5 (attached) requests a shared access with the R-6 properties adjacent to the site. When I asked Adam Moore of VDOT to further explain the comment, it truly seems to be a requirement and not a recommendation — please work with VDOT to iron out the final details with regard to the entrance as it does not appear the current location will be sufficient/approvable by VDOT without sufficient justification and a waiver. 7. [32.7.1.3] Dedication. Relabel the future 20' dedication along the frontage of the property as: "20' right-of-way area reserved for future dedication for public use upon demand of the County". 8. [32.5.2(a), 4.2.1, 4.2.2(b)] General information. Portions of this development are proposed on TMP 45-68C 1 (0.16 acres) and TMP 45-112A (0.715 acres), which rely on a boundary line adjustment (BLA) with these properties. Prior to final site plan approval the lot line adjustments shall take place on a subdivision plat to be reviewed by the County, approved, and then recorded in the Clerk's Office. The DB page information of this action shall be provided on the final site plan. [32.5.2(k), 32.7.5.1, 4.1] Water and sewer facilities. As part of the BLA of TMP 45-112A the reduced parcel will be reviewed to assure it contains adequate sewer and water services onsite. If the existing home is without either of these, it shall be required to connect to public water and/or public sewer as it is located in the jurisdictional area of the County. In order to not connect to both of these, the applicant shall provide a completed application for an exemption. Prior to BLA approval, the exemption shall be reviewed and a finding shall be made to either approve or deny the request. If the request is denied then public water and sewer shall be provided onsite and ACSA shall review/approve this aspect of the proposal. If the exemption request is approved to not provide public sewer and/or public water, the Health Department will be required to review/approve the BLA to assure adequate septic & water systems are provided onsite. 10. [32.5.2(i)] Easements. Improvements are proposed within the existing publically dedicated access easement (DB 1429 PG 122). The applicant proposes to relocate the easement in a New 15' VDOT access easement as depicted on TMP 04500-00-00-068C1. The easement shall be platted prior to final site plan approval. The plat shall be reviewed by the County & VDOT, approved, and then recorded in the Clerk's Office, the DB page information of this action shall be provided on the final site plan. 11. [32.5.1(c)] As proposed offsite grading is taking place on TMP 45-68C1 and TMP 45-68A. All offsite grading easements shall be applied for/reviewed/approved/recorded prior to final site plan approval. 12. [32.5.2(k)] Proposed sewer & water facilities. The proposed sanitary sewer line is located on TMP 45-68C1 and 45- 68A. The final site plan shall depict the entire extent of this easement on these properties from where the line originates along Route 29 to where it connects to Building A. Also, the proposed water connection for this site is located on TMP 45-112E. All offsite water and sewer easements shall be reviewed by the County, approved, and then recorded in the Clerk's Office prior to final site plan approval. The DB page information of this action shall be provided on the final site plan. 13. [32.5.2(j)] Existing sewer and drainage facilities. Label, dimension, and depict the existing and proposed water and sewer facilities and easements. 14. [32.5.2(b)] Proposed use. Label the proposed uses on sheet C1 with building designations: Building A New building supply sales - 11,000 SF (basement) New furniture sales - 7,000 SF (1St floor) - 4,000 SF (11 floor) New offices - 7,234 SF (2nd floor) Buildings B, C, D, E New outdoor storage, display, and sales - 28,360 SF 15. [4.12.6] Parking. Currently all onsite parking is being generated/calculated from uses within Building A. Provide parking calculations for Building C based on the following: Wholesaling or warehousing use not otherwise identified.- One dentified:One (1) space per employee plus one (1) space per each five hundred (500) square feet of floor area open to the public for customer parking, but in all cases a minimum of two (2) customer parking spaces. Revise parking calculations to include this use and label the spaces designated for employees. 16. [Comment] If customers are permitted in the loading and storage area please provide painted/striped directional arrows within the loading and storage area to provide a circulation pattern. 17. [32.7.2.3] Sidewalks and other pedestrian walkways. Are customers permitted within Building C? If so, it is sug eg sted the applicant provide pedestrians a safe and convenient walkway/marked path from the parking area to the building. 18. [4.12.13] Loading space. Label, dimension, and stripe the required loading spaces on site. Loading spaces shall be designed so as not to impede any required parking spaces, or any pedestrian or vehicular circulation. 19. [32.5.2(n), 4.12.13(e), 32.7.9.71 Existing and proposed improvements. A dumpster pad is required for the use based on gross square feet of the building. On the plan locate and dimension the dumpster pad for the site and provide required screening of the facility pursuant to section 32.7.9.7. The pad shall not impede any required parking or loading spaces, nor any pedestrian or vehicular circulation aisles. 20. [32.5.2(b)] Proposed use. Building B is labeled as an open shed. Label the sides of the building which are to be open, and label the sides which are to be solid walls (closed). 21. [32.5.2(b)] Proposed use. Some aspects of the proposal which are depicted on the initial site plan do not match what is proposed/depicted on the ARB submission and vice-versa. For example: 1) the extent of the screening fence along the northern property line 2) evergreen screening along the northern property line (25 plantings of eastern arborvitae & 4 plantings ofpin oaks). Prior to final site plan approval the differences between the two plans shall be rectified and properly depicted on the final site plan. 22. [32.7.9.6(a)] Landscaping within a parking area. Parking lot landscaping calculation incorrectly utilizes 79 spaces, revise calculations and plantings to utilize the correct parking count of 90 spaces, or final parking count if different. 23. [32.7.9.6(a)] Landscaping within a parking area. An area of at least five (S) percent of the paved parking and vehicular circulation area shall be landscaped with trees or shrubs. Parking lot landscaping calculations did not change from the 1 SI submittal to the 2°d submittal even with 18 additional parking spaces (2,916 SF of paved parking area) being added to the site. Revise the calculations to include the square footage from these spaces. 24. [4.12.15(g)] Curb and Gutter. Provide curb and gutter in the parking area and along the travelways. 25. [32.5.2(e), 32.7.9.4(c)] Existing landscape features. On the landscape plan identify whether remaining wooded areas are evergreen, deciduous, or a mix thereof. 26. [32.5.2(a)] General Information. Throughout the plan depict the zoning and the current uses of all abutting parcels (specifically the residentially zoned properties TMP 45-112 & 45-112E). 27. [32.5.1(c)] Dimensions. Label the existing dwelling on TMP 45-112A to remain or to be demolished. 28. [32.5.2(n)] Existing and proposed improvements. Dimension the full width and height of the retaining walls required for construction. Also, list the type of retaining wall used in the development (i.e., Geogrid, block/redi-rock walls). 29. [32.5.2(n)] Existing and proposed improvements. If there is to be a sign for the proposed use, on the final site plan depict and label the sign location. (Depicting the sign on the final site plan is not approval of the sign location or type). 30. [32.5.2(a)] Approval from the ARB is required prior to final site plan approval. See attached ARB review comments. 31. [32.5.2(n), 4.171 Outdoor lighting. If outdoor lighting is proposed a lighting plan meeting the requirements of section 4.17 shall be required prior to final site plan approval. 32. [Comment] The screening fence is blocking access to the stormwater treatment area. For maintenance purposes assure there is a way to access this area of the site. Please contact Christopher P. Perez in the Planning Division by using oerezL albemarle.org or 434-296-5832 ext. 3443 for further information. ('310"IMMONWEA171H of VIRGINIA DEPARTMENT OF TRANSPORTATION ?601 Orange Road Charles A. Kilpatrick, P.E. CuIPOW Virginia 22701 Commissioner July I8, 2016 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Christopher Perez Re: Better Living Berkmar Drive- Initial site plan SDP -2016-00018 Review #2 Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Shimp Engineering, dated March 6, 2016, with a revision date of June 13, 2016 and offers the following comments: Land Use 1. Please provide sight distance lines on the plans as well as the landscape plan sheet. Additionally please provide a sight distance profile on the plans. 2. Please see Road Design Manual appendix F -Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Provide a right turn lane warrant analysis as shown in F-96. Please refer to F-109 to provide the appropriate design vehicle and turning radius by land use. 3. Please conform to the pavement widening WP -2, 302_02 in the 2008 Road and Bridge standards. 4. Please provide Route number, Street name, Speed limit, and Right of Way width on all plan sheets. 5. VDOT recommends the proposed entrance be consolidated into one shared use entrance with the WoodNon Storch conceptual proposed entrance tax map parcel# 45- 112E. Shared use entrances are used to reduce the number of access points along a corridor while maintaining reasonable access to adjacent land uses. A shared use entrance generally serves only two parcels. The access Management Regulations 24VAC30-73-120 requires shared entrances where possible. Please refer to Appendix F., page F-23 and page F-118 for further reference. Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B ( 1) and F, as well as any other applicable standards, regulations, or other requirements. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Review Comments SDP201600018 Project Name- etter'Living Berkmar - initial Date Completed_ riday, July 08, 2016 Initial Site Plan Reviewer Vatthew Wentland Department/Division/Agency- Engineering Reviews Comments: Based on plans dated 06-13-2016, the following comments should be addressed on the final site plan and the VSMP plan: 1. A WPO submittal will be required containing ESC and SWM plans and a SWPPP [17-300. 17-301 ]. 2. Provide a barrier/guardrail where retaining walls are next to travelways. 3. Provide curb 8, gutter where necessary to control or direct stormwater runoff [18 4.12.15(g)]- 4, The County recommends acquiring temporary easements when work takes place within 5' of the propery line. 5. The condition and adequacy of the existing storm sewer may need to be verified for the VSMP submittal. 6. The runoff south of Buildings C & D may need to be directed to an adequate channel or converted to sheet flow. Review Comments SDP201600018 Project Name- otter Living Berkmar - initial Date Completed- vlonday, duly 11, 2016 Initial Site Plan Reviewer= Robbie Gilmer Department/DivisionlAgency- ; Fire Rescue Reviews Comments - Based on plans dated 6/13/16. �- - - - - - — -- 1. Please add a note to the plans " Knox Box required, please contact Albemarie County Fire Marshal once for location" 2. Fire Flow test required before final approval. 3. Hydrant spacing shall be a maximum of 400' per travel way. Please add a hydrant to the larger island as you enter the loading & Storage area. 4. FDG shall be located on the address side of the structure. 5. FDG shall have a hydrant with 100' per travel way. This will require a second hydrant located on Berkmar at the entrance. 6. Structures over 30' in height require aerial truck access of 26' clear travel way. Please increase the travel way in the east parking lot to 26' The travel lane to the north of the structure is already 26', but it shows a grade of 10°x'4 and our aerial trucks can only over come 8% front to back- Project Name: Date Completed- Reviewer- Department/Divisior /Agency- Reviews Comments: Review Comments SDP201600018 atter Living Berkrnar - initial vlonday, July 11, 2016 3atricia Saternye ARB Initial Site Plan - l -J The Better Living Initial Site Plan is scheduled for the August 1, 2016 ARB meeting The ARB Staff Report will be able to be accessed under ARB201600039 in County View on or before the ARB meeting date. Christopher Perez From: Alexander Morrison<amorri son @sery iceauthority. org> Sent: Monday, July 25, 2016 10:31 AM To: Christopher Perez Subject: SDP201600018: Better Living Berkmar - Initial Chris, I have reviewed the resubmittal and hereby recommend approval of SDP201600018 with the following conditions: ACSA construction plan submittal will be required for the final site plan. Fire protection on site will be required (fire hydrant placement will be reviewed in the construction plan submittal). Let me know if you have any questions. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434-977-4511 Ext. 116 (C) 434-981-5577 (F) 434-979-0698 Reviews Comment. SDP201600018 Project Name: atter Living Berkmar - initial Date Completed: ' vlonday, June 20, 2016 Initial Site Plan Reviewer: jay Schlothauer DepartmentEDivisionAgency: Inspections Reviews Comments: Based on plans revised June 13, 2016 No further comments or conditions. 0 Project Name: Date Completed: Review Comment SDP201600018 atter Living Serkmar - Initial Thursday, June 23, 2016 Reviewer_ Mdrew Slack DepartmentlDivisioWAgencY: E911 Reviews Comments: No Objection. initial Site Plan LI Christopher Perez From: Alexander Morrison<amorrison@serviceauthority.org> Sent: Monday, July 25, 2016 10:31 AM To: Christopher Perez Subject: SDP201600018: Better Living Berkmar - Initial Chris, I have reviewed the resubmittal and hereby recommend approval of SDP201600018 with the following conditions: • ACSA construction plan submittal will be required for the final site plan. • Fire protection on site will be required (fire hydrant placement will be reviewed in the construction plan submittal). Let me know if you have any questions. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434-977-4511 Ext. 116 (C) 434-981-5577 (F) 434-979-0698 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Charles A. Kilpatrick, P.E. Culpeper Virginia 22701 Commissioner July 18, 2016 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Christopher Perez Re: Better Living Berkmar Drive- Initial site plan SDP -2016-00018 Review #2 Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Shimp Engineering, dated March 6, 2016, with a revision date of June 13, 2016 and offers the following comments: Land Use I . Please provide sight distance lines on the plans as well as the Iandscape plan sheet. Additionally please provide a sight distance profile on the plans. 2. Please see Road Design Manual appendix F -Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Provide a right turn lane warrant analysis as shown in F-96. PIease refer to F-109 to provide the appropriate design vehicle and turning radius by land use. 3. Please conform to the pavement widening WP -2, 302_02 in the 2008 Road and Bridge standards. 4. Please provide Route number, Street name, Speed limit, and Right of Way width on all plan sheets. 5. VDOT recommends the proposed entrance be consolidated into one shared use entrance with the WoodNon Storch conceptual proposed entrance tax map parcel# 45- 112E. Shared use entrances are used to reduce the number of access points along a corridor while maintaining reasonable access to adjacent land uses. A shared use entrance generally serves only two parcels. The access Management Regulations 24VAC30-73-120 requires shared entrances where possible. PIease refer to Appendix F., page F-23 and page F-118 for further reference. Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B ( 1) and F, as well as any other applicable standards, regulations, or other requirements. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Christopher Perez From: Christopher Perez Sent: Monday, May 02, 2016 8:38 AM To: Justin Shimp Subject: SDP201600018 Better Living Berkmar- Initial Site Plan Attachments: SDP201600018 Better Living Berkmar-initial site plan 5-2-16.pdf Justin, SDP201600018 Better Living Berkmar- Initial Site Plan Attached are SRC comments for the above referenced plan. Comments from Fire& Rescue, ACSA, ARB, and VD9(reviews pending, to be forwarded once recieved. Prior to initial site plan approval, at a minimum, Planning's comments 1 — 11 shall be addressed in a resubmittal of the initial site plan. The applicant shall request the project be deferred to allow required revisions and ARB review of the revisions to take place prior to action on the plan. Christopher P.Perez 1 Senior Planner Department of Community Development 1County of Albemarle, Virginia 401 Mclntire Road 1 Charlottesville,VA 22902 434.296.5832 ext. 3443 1 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 May 2, 2016 Justin Shimp 201 E. Main Street Charlottesville VA 22902 SDP201600018 better Living Berkmar — Initial Site Plan Mr. Shimp: The Site Review Committee has reviewed the development proposal referenced above. Initial comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services Albemarle County Engineering Services Albemarle County Information Services (E911) Albemarle County Building Inspections Albemarle County Department of Fire Rescue [Comments pending to be forwarded once received] Albemarle County Service Authority [Comments pending to be forwarded once received] Architectural Review Board (ARB) [Comments pending to be forwarded once received] Virginia Department of Transportation [Comments pending to be forwarded once received] Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to Final Site Plan approval. Prior to initial site plan approval a resubmittal of the elan is reauired. The annlicant shall reauest the nroiect be deferred to allow reauired revisions and ARB review of the revisions to take place prior to action on the plan. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Senior Planner County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 Phone 434-296-5832 Memorandum To: Justin Shimp From: Christopher P. Perez, Senior Planner Division: Planning Date: May 2, 2016 Subject: SDP201600018 Better Living Berkmar - Initial Site Plan Fax 434-972-4126 The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] Prior to initial site plan approval, at a minimum, comments 1-11 shall be addressed in a resubmittal. 1. [Comment] The public notification fee of $215 was not paid prior to the SRC meeting. Please pay the fee prior to any further review/action of the plan. 2. [32.5.2(p), 32.7.9.2(b), 30.6.31 Proposed use. Pursuant to Section 30.6.3, Outdoor Storage located in and visible from the Entrance Corridor (EC) requires a Special Use Permit (SP). If the outdoor storage is completely screened and is determined by the Architectural Review Board (ARB) not to be visible from the EC, then a SP is not required. If ARB determines it to be visible from the EC then a SP shall be required prior to approval of the initial site plan. Based on the above, prior to initial site plan approval a complete landscape plan for the entire site that complies with section 32.7.9 is required. Also, address any ARB landscaping and screening comments once ARB review is complete. The applicant shall request the project be deferred to allow required revisions and ARB review of the revisions to take place prior to action on the plan. 3. [32.5.2(e), 32.7.9.4(c)] Existing landscape features. On the landscape plan depict the existing tree line and identify whether existing wooded areas are evergreen, deciduous, or a mix thereof. 4. [32.7.9.8] Tree Canopy. The Ilex glabra (inkberry holly) plantings shall not be counted towards the required tree canopy calculations for the site because they only grow to be 4 feet tall at a maturity of ten years. Only plantings exceeding 5 feet in height at ten years shall be counted towards required tree canopy. [32.7.9.8] Tree Canopy. The applicant seeks to establish a canopy bonus of 11,432 SF by preserving 9,146 SF of existing trees within the 20' undisturbed buffer area to meet the minimum required tree canopy for the site; however, the buffer area does not contain many trees due to the existing overhead utility line/easement which runs through the buffer. The trees that are located in this buffer are located on the very edge of the buffer adjacent to the proposed retaining wall and asphalt parking lot. Impervious site improvements will cover the majority of the root system of the trees, causing them to die. The end result will be a site that does not meet the minimum canopy requirements. To further assess the landscaping being preserved in the buffer, please depict the location, caliper, size and species of the trees within this area. 6. [32.7.9.4] Plantings. Three (3) zelkova serrata are located overtop the new HDPE storm sewer line. Either relocate the plantings off the line or relocate the line to avoid the conflict. Staff recommends the line be relocated slightly as the plantings may be required by ARB. [32.7.9.4(b)] Existing trees may be preserved in lieu of planting new plant materials in order to satisfy the landscaping and screening requirements of section 32.7.9, subject to the agent's approval. If you intend to use existing trees to satisfy any of the landscape plan requirements, please include the following: 1. Areas and other features shown on landscape plan. The landscape plan shall show the trees to be preserved, the limits of clearing, the location and type of protective fencing, grade changes requiring tree wells or walls, and trenching or tunneling proposed beyond the limits of clearing. 2. Conservation checklist. The applicant shall sign a conservation checklist approved by the agent to ensure that the specified trees will be protected during construction. Except as otherwise expressly approved by the agent in a particular case, the checklist shall conform to the specifications in the Virginia Erosion and Sediment Control Handbook, pages I1I-393 through 11I-413, and as hereafter amended. 8. [32.5.1(c) & (d)] Topography. Provide existing topography and proposed grading for all areas of the site. Also, provide offsite topography to describe prominent and pertinent offsite features and physical characteristics, but in no case less than fifty (50) feet outside of the site. 9. [32.5.20),(k),(1)] Existing and proposed utilities. On the landscape plan depict, label and dimension all existing and proposed utilities and utility easements including water, sewer, drainage, telephone, cable, electric and gas. Label all existing easements with the Deed Book and Page Number. The above information shall be used to verify that no conflicts exist between landscaping and utilities. 10. [32.5.2(n), 32.5.1(c)] Dimensions. On the plan dimension all proposed improvements, including all buildings (A, B, and C), retaining walls, screening fence, and storage areas. 11. [32.5.2(b)] Proposed use. On sheet C1 revise the proposed use to include `outdoor storage, display and/or sales', and the use associated with buildings B and C. Label buildings B and C as three walled structures. Also, provide the maximum acreage occupied by these uses. 12. [21.7, 4.20(a)21 Setbacks. Building `A' does not meet the maximum 30 foot front setback along Berkmar Drive. Either modify the building location to meet the maximum front setback or request a special exception (SE) to the requirement. If a SE is requested provide a SE application and the review fee of $457. Also provide justification of the request to include reason for the request and how it fits with the recommendations in the Comprehensive Plan. Prior to final site plan approval the applicant shall receive approval of the SE by the Board of Supervisors (BOS). With or without the SE request it is recommended that the applicant provide a reservation for dedication upon demand of the county for the future widening of Berkmar Drive. This reservation should be a total of 44 feet from the centerline of Berkmar Drive. 13. [21.7(c)] Buffer zone adjacent to residential districts. The 20 foot undisturbed buffer shall be extended to the right-of- way for Berkmar Drive. Unauthorized clearing, grading, and plantings of street trees are proposed within the buffer. Either modify the plans to omit any disturbance within this buffer or request a SE to waive the requirement. If a SE is requested provide a SE application and the review fee of $457. Also provide the required justification of the request. Prior to final site plan approval the applicant shall receive approval of the SE by the BOS. 14. [32.5.2(a)] General Information. Development is proposed on portions of TMP 45-68C1 and TMP 45-112A. Prior to final site plan approval the boundary line adjustments shall take place on a subdivision plat to be reviewed by the County, approved, and then recorded in the Clerk's Office. The DB page information of this action shall be provided on the final site plan. It may be appropriate to combine all platting items on a single plat (if other items exist). 15. [32.5.2(i)] Easements. Improvements are proposed with the existing publically dedicated access easement (DB 1429 PG 122). The easement provides access to the existing drainage easement on TMP 45-68C1. The easement shall be vacated and relocated prior to final site plan approval. The vacation shall take place on a plat to be reviewed by the County, approved, and then recorded in the Clerk's Office prior to final site plan approval. The DB page information of this action shall be provided on the final site plan. The vacation/relocation will require BOS approval. 16. [32.5.1(c)] As proposed offsite grading is taking place on TMP 45-68C1 and TMP 45-68A. All offsite grading easements shall be applied for/reviewed/approved/recorded prior to final site plan approval. 17. [32.5.2(a)] General Information. Throughout the plan depict the departing lot lines, zoning, and the uses of all abutting parcels (specifically the residentially zoned properties TMP 45-112 & 45-112E). 18. [32.5.2(k)] Proposed sewer facilities. Depict the proposed sanitary sewer line from where it originates along Route 29 to where it connects to Building A. Offsite sewer easements shall be reviewed by the County, approved, and then recorded in the Clerk's Office prior to final site plan approval. The DB page information of this action shall be provided on the final site plan. 19. [32.5.20)] Existing sewer and drainage facilities. Depict the location and size of existing water and sewer facilities and easements. 20. [32.5.1(c)] Dimensions. Depict and dimension the existing dwelling on TMP 45-112A and label whether it is to remain or to be demolished. 21. [32.5.2(n)] Existing and proposed improvements. Dimension the full width and height of the retaining walls required for construction. Also, list the type of retaining wall used in the development (i.e., Geogrid, block/redi-rock walls). 22. [32.5.2(n)] Existing and proposed improvements. Clearly depict and label limits of disturbance and show areas where existing vegetation will be removed. 23. [4.12.15(g)] Curb and Gutter. Provide curb and gutter in the parking area and along the travelways. 24. [32.5.2(n)] Existing and proposed improvements. If there is to be a sign for the proposed use, on the final site plan depict and label the sign location. (Depicting the sign on the final site plan is not approval of the sign location or type). 25. [32.5.2(n), 4.12.13(e), 32.7.9.7] Existing and proposed improvements. A dumpster pad is required for the use based on gross square feet of the building. On the plan locate and dimension the dumpster pad for the site and provide required screening of the facility pursuant to section 32.7.9.7. The pad shall not impede any required parking or loading spaces, nor any pedestrian or vehicular circulation aisles. 26. [32.7.2.1] Vehicular Access to Site. Each entrance onto any public street shall be designed and constructed as required by the standards of the Virginia Department of Transportation. VDOT approval of the entrance to the site shall be required prior to final site plan approval. 27. [32.5.2(a)] On the cover sheet of the initial site plan provide the site plan number: SDP2016-18. 28. [32.5.2(a)] Approval from the ARB is required prior to final site plan approval. See attached ARB review comments. 29. [32.5.2(n), 4.171 Outdoor lighting. If outdoor lighting is proposed a lighting plan meeting the requirements of section 4.17 shall be required prior to final site plan approval. 30. [Comment] The screening fence is blocking access to the stormwater treatment area. For maintenance purposes assure there is a way to access this area of the site. Please contact Christopher P. Perez in the Planning Division by using cperez@albemarle.org or 434-296-5832 ext. 3443 for further information. Review Comments MIM911IM1,11+1E. Project Name- etter Living Berkmar - initial Date Completed: Oonday, April 25, 2016 Reviewer: liluatthew Wentland Initial Site Plan F- �J Department1DivisionrAgency: Engineering Reviews Comments Based on plans dated 03-21-2016- 1. A WPO submittal will be required containing ESC and SWM plans and a SWPPP [17-300, 17-301]. 2. In managed slopes, the maximum retaining wall height is 6with a minimum T separation beN,een tiered walls [18.30.7.5(a)]. 3. Provide a barrier/guardrail where retaining walls are next to travetways. 4. Provide gutters where necessary to control or direct stormwater runoff [18.4.12.15(g)]. • Review Comments SDP201600018 Project Name: atter Living Berkmar - Initial Date Completed: Tuesday, April 05, 2016 Initial Site Plan L• Reviewer: 4ndrew Slack Department/Divisiori.Agency: E911 Reviews Comments: Review Comments SDP201600018 Project Name: etter Living Berkmar - Initial Date Completed: Nednesday, April 20, 2016 Initial Site Plan Reviewer: Jay SchlothauerqV De artmentiDivision rA encY= Inspections i Reviews Comments ; (79), a total of four harrier -free parking spaces are required. s, with associated striped access aisle and curb cut. COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1681 Orange Road Culpeper, Virg:nia 22701 Charles A. Kilpatrick, P.E. Commissioner April 29, 2016 Christopher Perez County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP -2016-00018 Better Living Berkmar Drive — Initial Site Plan Dear Mr. Perez We have reviewed the Better Living — Initial Site Plan; with an initial submittal date of March 2I, 2016, as submitted by Shimp Engineering, and offer the following comments: 1- Sight lines/distances need to be added to the site plan for proposed entrance from Berkmar Drive to help determine whether the proposed entrance wilI have sight distance issues or not. 2. Possible issue with landscaping (trees) within sight line of Berkmar Drive? Please show sight distance profile on landscaping plans. 3. Commercial entrance design along Berkmar drive. Please see Road Design Manual appendix F -Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Provide a right turn lane warrant analysis as shown in F-96. Please refer to F-109 to provide the appropriate design vehicle and turning radius by land use. 4. Please conform to the pavement widening WP -2, 302_02 in the 2008 Road and Bridge standards. Please see attachment. If you need further information concerning this project please do not hesitate to contact me at 434-422-9373. Joel DeNunzio, P.E. Residency Engineer VDOT Charlottesville Residency