HomeMy WebLinkAboutARB201600109 Plan - Approved Architectural Review Board Approval 2016-10-04Charlottesville
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Top of Sign To Grade = 18'-10 1/4"
Bottom of Sign To Grade = 14'-5"
89.24 (Boxed)
Internally Illuminated LED
33" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN A
Channel Letters on a Raceway
Mattress Firm replacement panel
New 3/16" white Lexan w/ applied vinyl
23-3/4" x 47-3/4"
7.87
21-3/4" x 45-3/4"
Sign Type:
Actual Size:
Viewable Size:
Square Footage:
SIGN C
Existing Internal IlluminationIllumination:
Sign A
Sign B
Sign C
R
i
v
a
n
n
a
P
l
a
z
a
D
r
Ga
n
d
e
r
D
r
Se
m
i
n
o
l
e
T
ra
i
l
Top of Sign To Grade = 17'-6"
Bottom of Sign To Grade = 13'-11"
59.66 (Boxed)
Internally Illuminated LED
27" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN B
Channel Letters on a Raceway
Front Elevation (Northwest)
Scale: 3/32” = 1’-0"
Existing
Combined Allowable Square Footage:160.00
Actual Square Footage this Elevation:89.24
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Top of Sign To Grade = 18'-10 1/4"
Bottom of Sign To Grade = 14'-5"
89.24 (Boxed)
Internally Illuminated LED
33" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN A
Channel Letters on a Raceway
23
’
-
4
”
60
"
47
1
/
4
”
EQ
EQ
33'-0"
41'-0"
28'-3"EQEQ
80'-0" Lease Dimension
Combined Actual Square Footage:148.90
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Top of Sign To Grade = 17'-6"
Bottom of Sign To Grade = 13'-11"
59.66 (Boxed)
Internally Illuminated LED
27" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN B
Channel Letters on a Raceway
Rear Elevation (Southeast)
Scale: 3/16” = 1’-0"Actual Square Footage this Elevation:59.66
Combined Allowable Square Footage:160.00
Combined Actual Square Footage:148.90
33'-0" Sign Band
41'-0" Across Outside Columns
80’-0” Lease Dimension
191"186”
8'-7 1/2"75 1/2"7"176 1/2"7"7"
60
”
S
i
g
n
B
a
n
d
38
1
/
2
”
6”
15
1
/
2
”
90
”
15
5
”
B
o
t
t
o
m
o
f
S
i
g
n
B
a
n
d
t
o
G
r
a
d
e
60
”
S
i
g
n
B
a
n
d
27
”
17
1
/
2
”
15
1
/
2
”
NOTE: “S” in “Mattress” and “F” in “Firm” are equal distance (7”) from drain spout
Existing
1" x 2" x 1/8" aluminum tube mounting
and wireway. (Notched into raceway)
Painted to match raceway
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Scale: 1/4" = 1'-0"
Sign Layout Detail
GE White LEDs
(4) 60w Transformers @ 1.2 amps each
Total Amps: 4.80
(1) 20 amp 120V Circuit Req.
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7/NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
Top of Sign To Grade = 18'-10 1/4"
Bottom of Sign To Grade = 14'-5"
89.24 (Boxed)
Internally Illuminated LED
33" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN A
Channel Letters on a Raceway
NOTE: The level of illumination provided by the
LED lights will not exceed the illumination produced
by a single stroke of 30 milliamp (ma) neon.
Specifications: Channel Letters/ Raceway
1. Existing Facade: Brick / Drywall / Metal
2. 0.040” Aluminum letter returns painted to match Bronze
3. 0.125” x 1” trim cap to match Bronze
4. 3mm Signabond Lite composite backs
(interior of sign can painted ultra white for maximum illumination)
5. White LEDs
6. 3/16” acrylic faces;
R&H #7328 White Acrylic for letters
R&H #2016 Yellow Acrylic for “Swoosh” (PMS 123 Yellow)
3m #7725-12 Gloss Black vinyl ‘drop shadow’ on swoosh
7. Waterproof disconnect switch per NEC 600-6
8. Primary electrical feed
9. Transformers
10. 0.080” Aluminum raceway painted to match the facade
11. 15” x 2” x 0.1875” Aluminum mounting tabs welded to raceway
- Maximum 6” from each end and every 48” o.c.
12. #12 x 1” TEC screws with 1 1/4” fender washers
13. Mounting hardware; 3/8” Sleeve Anchors
¼” Drain holes at bottom
of letter cans (2) per letter
Scale: N.T.S.
5”
Se ct i on @ L E D Channe l Le t te r
F r ont -Li t (Rac eway)
1
2
4
12
5
6
3
7”
9
8
10
7
11
13
33
"
47
1
/
4
”
1 1
1
/
2
”
28'-3"339"
9'-8 3/4"
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Scale: 1/4" = 1'-0"
Sign Layout Detail
GE White LEDs
(3) 60w Transformers @ 1.2 amps each
Total Amps: 3.60
(1) 20 amp 120V Circuit Req.
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7/NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
Top of Sign To Grade = 17'-6"
Bottom of Sign To Grade = 13'-11"
59.66 (Boxed)
Internally Illuminated LED
27" Mattress Firm linear
Sign Type:
Illumination:
Square Footage:
To Grade:
SIGN B
Channel Letters on a Raceway
NOTE: The level of illumination provided by the
LED lights will not exceed the illumination produced
by a single stroke of 30 milliamp (ma) neon.
¼” Drain holes at bottom
of letter cans (2) per letter
Scale: N.T.S.
5”
Se ct i on @ L E D Channe l Le t te r
F r ont -Li t (Rac eway)
1
2
4
12
5
6
3
7”
9
8
10
7
11
13
Specifications: Channel Letters/ Raceway
1. Existing Facade: Brick / Drywall / Metal
2. 0.040” Aluminum letter returns painted to match Bronze
3. 0.125” x 1” trim cap to match Bronze
4. 3mm Signabond Lite composite backs
(interior of sign can painted ultra white for maximum illumination)
5. White LEDs
6. 3/16” acrylic faces;
R&H #7328 White Acrylic for letters
R&H #2016 Yellow Acrylic for “Swoosh” (PMS 123 Yellow)
3m #7725-12 Gloss Black vinyl ‘drop shadow’ on swoosh
7. Waterproof disconnect switch per NEC 600-6
8. Primary electrical feed
9. Transformers
10. 0.080” Aluminum raceway painted to match the facade
11. 15” x 2” x 0.1875” Aluminum mounting tabs welded to raceway
- Maximum 6” from each end and every 48” o.c.
12. #12 x 1” TEC screws with 1 1/4” fender washers
13. Mounting hardware; 3/8” Sleeve Anchors
27
"
38
1
/
2
”
9
1
/
2
”
23'-1 1/2"277 1/2"
7'-11 1/2"
Mattress Firm
MF-171007
315 Rivanna Plaza Drive
Charlottesville, VA. 22901
Charlottesville
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
07/28/2016 Updated LEDs JEH
08/03/2016 Updated LEDs JEH
08/18/2016 Updated Multi-Tenant Vinyl JEH
08/22/2016 Updated Site Address & Added LED note JEH
09/01/2016 Updated Square Footage JEH
09/17/2016 Revisions JEH
09/30/2016 Sign B Revisions JEH
Scale: 1” = 1’-0”QTY 2 (1 SET)
Panel Replacement On Existing D/F Pylon
Existing
1
2
Mattress Firm replacement panel
New 3/16" white Lexan w/ applied vinyl
23-3/4" x 47-3/4"
7.87
21-3/4" x 45-3/4"
Sign Type:
Actual Size:
Viewable Size:
Square Footage:
SIGN C
Existing Internal IlluminationIllumination:
Proposed
1. New 3/16" white lexan
2. New first surface applied vinyl:
3m #3630-53 Cardinal Red (PMS 187 Red)
3m #7725-12 Gloss Black
Arlon #2500-3279 Yellow (PMS 123 Yellow)
- Second Surface
First layer Opaque White #7725-10
Second layer Opaque Black #7725-12
Specifications:
18
1
/
4
”
21
3
/
4
”
23
3
/
4
”
45 3/4”
47 3/4”
NOTE: The tenant panel background shall be opaque.
Only the red and yellow colors of the text and graphic shall illuminate