HomeMy WebLinkAboutSDP201600041 Review Comments Minor Amendment 2016-10-31 'I;
Notably Alex is out of the office till Nov 4th. Please work with Jeremy Lynn or someone else at ACSA to
provide this approval.Otherwise it may have to wait till Alex comes back.
,
Thank you for your patience.
1 Christopher P.Perez I Senior Planner
i Department of Community Development(County of Albemarle,Virginia
401 McIntire Road I Charlottesville,VA 22902
434.296.5832 ext.3443
From: Rob Umberger[mailto:r 0.-:-- -- • wwa ,►*.
tes.net]
Sent:Thursday, October ., 2016 3:13 PM
To:Sarah Baldwin .•aldwin'• albemarl-..r:>
Cc:Christopher •-rez<cperez@albem:rle.org>
3
Subject: Faro'ington Country Club East 9
li Sarah,
W- submitted the final version of the amendment earlier this week. !just found out that 'hris is out on leave. I think
t .t this is the last thing that Farmington needs to move on with the building.
I Is there any way that we can get this either approved or get the permits released so that the can start?
i
Thanks,
1
Rob Umberger
1.1
Project Manager
4
` ' *ATM
O' ice Phone: 434.960.7589
Mai I: 434.984.2700
Fax: - 4.978.1444
I 3040 A emore Square Place
Charlotte'ville,`VA 22911
rumberger ?wwassociates.net
11 www.wwasso '.tes.net
III
o
i I
E
1
F
r
k
I
2
P
0
Christopher Perez
From. Christopher Perez
Sent: Monday, October 31, 2016 3:40 PM
To: 'Alexander Morrison'; rumberger@wwassociates.net
Cc: Sarah Baldwin;Jeremy Lynn
Subject: RE:SDP201600041—Farmington Country Club (minor amendment)
Rob,
Please bring in a min of 4 copies of the site plan(signed/sealed) and I'll approve it. Thanks
Christopher P.Perez 1 Senior Planner
Department of Community Development Countyof Albemarle,Virginiainia
401 McIntire Road Charlottesville,VA 22902
434.296.5832 ext.3443
From:Alexander Morrison [mailto:amorrison@serviceauthority.org]
Sent: Monday,October 31, 2016 3:38 PM
To:Christopher Perez<cperez@albemarle.org>; rumberger@wwassociates.net
Cc:Sarah Baldwin<sbaldwin@albemarle.org>;Jeremy Lynn<jlynn@serviceauthority.org>
Subject: RE:SDP201600041—Farmington Country Club (minor amendment)
Chris,
I have reviewed the re-submittal and hereby recommend approval. Let me know if you need anything further.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville,Virginia 22911
(0)434-977-4511 Ext. 116
(C)434-981-5577
(F) 434-979-0698
From: Christopher Perez [mailto:cperez@aalbemarle.orq]
Sent: Monday, October 31, 2016 10:29 AM
To: rumberger(awwassociates.net
Cc: Sarah Baldwin; Alexander Morrison;Jeremy Lynn
Subject: SDP201600041 Farmington Country Club (minor amendment)
Rob,
SDP201600041 —Farmington Country Club (minor amendment)
As discussed over the phone, I have completed my review of the required revisions and all Planning&
Engineering items have been addressed.
Prior to County approval of the plan I need something in writing from ACSA giving their approval. The last
round of comments from Alex Morrison was from Aug 22, 2016 in which he requested revisions.
1
A
1
Christopher Perez
3
From: Christopher Perez
Sent: Monday, October 31, 2016 10:29 AM
To: rumberger@wwassociates.net
44 Cc: Sarah Baldwin;Alex Morrison;'Jeremy Lynn'
Subject: SDP201600041—Farmington Country Club (minor amendment)
4
Rob,
4
SDP201600041 —Farmington Country Club(minor amendment)
As discussed over the phone, I have completed my review of the required revisions an. . 1 Planning&
I Engineering items have been addressed.
Prior to County approval of the plan I need something in writing from ACSA 1_, ing their approval. The last
round of comments from Alex Morrison was from Aug 22, 2016 in which ' requested revisions.
11 Notably Alex is out of the office till Nov 4th•Please work with Jere y n or someone else at ACSA to
3,1 provide this approval. Otherwise it may have to wait till Alex comes sack.
Thank you for your patience.
Christopher'P.Perez j Senior Planner
-I Department of Community Development 1County of Albemarle,Virginia
-4
4' 401 McIntire Road l Charlottesville,VA 22902
434.296.5832 ext.3443
Ai
From: Rob Umberger[mailto:rumberger(a�wwassociates.net]
Sent:Thursday, October 20,2016 3:13 PM
To:Sarah Baldwin<sbaldwin@albemarle.org>
Cc:Christopher Perez<cperez@albemarle.org>
Subject: Farmington Country Club East 9
1 Sarah,
We submitted the final version of the amendment earlier this week. I just found out that Chris is out on leave. I think
that this is the last thing that Farmington needs to move on with the building.
'iIs there any way that we can get this either approved or get the permits released so that they can start?
i Thanks,
Rob Umberger
Project Manager
ItAteitlitlt
1 ASSOCIATES
1 Office Phone: 434.960.7589
Main: 434.984.2700
Fax:434.978.1444
3040 Avemore Square Place
1 1
L
a
Is
Charlottesville,VA 22911
rumberger@a,wwassociates.net
www.wwassociates.net
ffi
2
Short Review Comments Report for:
SDP201600041
SubApplication Type:
Farmington Country Club - Golf Academy - Amendment
Amendment to Site Development Plan
Date Completed:07/18/2016
Reviewer:Margaret Maliszewski ARB
Review Status:Requested Changes
Reviews Comments:It appears that the covered practice facility structure will not be visible from the Entrance Corridor.
However, grading and building construction will remove existing trees from along Farmington Drive
and from the EC side of the structure. The architectural rendering submitted at the pre-application
conference shows trees in the immediate vicinity but no new landscaping is shown on the site plan.
Revise the plan to show the landscaping that is proposed for the areas of removed trees 1) on the
EC side of the practice facility and 2) along Farmington Drive, for a distance of 500’ from the property
line that runs more-or-less parallel to Rt. 250.
Division:
Date Completed:07/20/2016
Reviewer:Matthew Wentland Engineering
Review Status:No Objection
Reviews Comments:
Division:
Date Completed:08/08/2016
Reviewer:Christopher Perez CD
Review Status:See Recommendations
Reviews Comments:Applicant resubmitted before I was able to conducted my 1st review. Will review the revised version.
CPP
Division:
Date Completed:07/21/2016
Reviewer:Jay Schlothauer Inspections
Review Status:No Objection
Reviews Comments:
Division:
Date Completed:07/16/2016
Reviewer:Robbie Gilmer Fire Rescue
Review Status:No Objection
Reviews Comments:Based on plans dated 6/16/16.
No comments or objections.
Division:
Date Completed:08/08/2016
Reviewer:Alexander Morrison ACSA
Review Status:See Recommendations
Reviews Comments:Alex had one comment that needed to be rectified.
Division:
Date Completed:08/08/2016
Reviewer:Josh Kirtley Health Department
Review Status:Approved
Reviews Comments:
Division:
Date Completed:08/22/2016
Reviewer:Alexander Morrison ACSA
Review Status:Requested Changes
Reviews Comments:
Division:
Page:1 of 2 County of Albemarle Printed On:November 07, 2016
Reviews Comments:
Date Completed:08/23/2016
Reviewer:Christopher Perez CD
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:08/22/2016
Reviewer:Margaret Maliszewski ARB
Review Status:No Objection
Reviews Comments:
Division:
Date Completed:10/31/2016
Reviewer:Christopher Perez CD
Review Status:No Objection
Reviews Comments:all comments addressed.
Division:
Date Completed:10/31/2016
Reviewer:Alexander Morrison CD
Review Status:Approved
Reviews Comments:296.5832 ext. 3443
From: Alexander Morrison [mailto:amorrison@serviceauthority.org]
Sent: Monday, October 31, 2016 3:38 PM
To: Christopher Perez <cperez@albemarle.org>; rumberger@wwassociates.net
Cc: Sarah Baldwin <sbaldwin@albemarle.org>; Jeremy Lynn <jlynn@serviceauthority.org>
Subject: RE: SDP201600041 – Farmington Country Club (minor amendment)
Chris,
I have reviewed the re-submittal and hereby recommend approval. Let me know if you need anything
further.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(O) 434-977-4511 Ext. 116
(C) 434-981-5577
(F) 434-979-0698
Division:
Page:2 of 2 County of Albemarle Printed On:November 07, 2016
ENGINEERS
SURVEYORS
PLANNERS
ASSOCIATES
October 18,2016
Christopher P. Perez
Senior Planner
Planning Division
County of Albemarle
Department of Community Development
401 McIntire Road,North Wing
Charlottesville, VA 22902-4596
Re: Farmington Country Club Site Plan—Minor Amendment
WWA Project No. 214045
Dear Mr. Perez:
Enclosed please find two copies of the revised plans and specifications for the
Farmington Country Club Site Plan. I have prepared the following summary in response
to your comments and concerns dated August 23, 2016.
Comment: [32.5.2(n)] Existing and proposed improvements. As discussed at the
12-7-15 pre application meeting, there is not an existing site plan covering this
specific area of the site; rather, SDP2001-55 is the closet known plan. Provide an
additional sheet in this plan set similar to sheet 2/8 of SDP2001-55, which depicts a
detailed overview of the area these improvements are taking place on.
Response: Drawing Number C-2A has been added to the set depicting the overall area.
=12. Comment: [32.5.2(d)] Topography and proposed grading. Provide an existing
conditions sheet, which includes existing topography, including any critical slopes.
Response: An Existing Conditions Sheet has been added, see Drawing Number C-2B.
i
„3. Comment: 132.5.2(b)] Information regarding proposed use. Provide the maximum
amount of impervious cover on this specific portion of the site.
Response: Impervious areas and building areas have been added to the Cover Sheet,
Drawing Number C-1.
3040 Avemore Square Place •Charlottesville,VA 22911
Telephone(434)984-2700 •Fax(434) 978-1444
Charlottesville•Lynchburg
7 i Comment: [32.5.2(n)] Existing and proposed improvements. Provide widths of
concrete apron along the front of building.
Response: The width of the concrete aprons have been added to the plan. See
architectural drawings for more detail.
5. Comment: 132.5.2(n)] Existing and proposed improvements. Provide the square
footage of the building.
1P----onset The square footage of the building has been added to the Cover Sheet,
Drawing Number C-l.
6. omment: [32.5.1(c)] Dimensions. Provide height and width of the retain wall.
i Response: The retaining wall height and length has been added to the drawings. See
architectural drawings for additional information.
7. Comore t: [32.5.1(c)] Dimensions. Provide the width of all areas of the pathway
- depict on the plans. Specifically, the portion which flares out to 20 foot.
Response: The cart paths in the project area are labeled on drawing number C-3. The 20'
cart parking from the previous plan has been dimensioned.
8. Comment- 2.5.2(a)] General information. Clearly depict and label the property line
for the cel nearest Rte 250. Also, depict and label Rte 250.
Response: The property line has been labeled as well as Rt. 250.
9. Comment- 32.5.2(k)] Proposed sewer and drainage facilities. Indicate the direction
of flow ' 1 pipes with arrows.
Response: Flow arrows have been added for the sanitary and storm pipes.
10. C ent: — 132.5.2(a)] General Information. Revise the setbacks noted on sheet 1
to i Jude 75 foot setback from existing public road. Also, remove the parking setbacks
m the plan, as there are no parking spaces proposed.
Response: The setbacks have been updated on the cover sheet.
3040 Avemore Square Place •Charlottesville,VA 22911
Telephone(434) 984-2700 •Fax(434)978-1444
Charlottesville •Lynchburg
Page 2 of 4
*emir 'yaws+
11. omment: Revise the note on sheet 3 of 4 which reads "Existing trees to remain to
p vide screening protection during construction" to "Existing trees to remain to provide
Greening protection."
Response: The note has been updated.
12. C ment: —Provide deed book page reference number for all existing easements
o ' e, specifically the relocated gas line of Charlottesville Gas.
Response: T eed book and page numbers for the easements have been added.
13. mment: A WPO buffer is depicted on sheet 4. Provide a label for this buffer.
• esponse: The WPO buffer has been labeled on Drawing Number C-4.
14. Comment: 132.6.2(k)ft-4171 Lighting. Is any outdoor lighting proposed with the
site plan amendment? so, lighting (including building mounted fixtures)must be
shown on a lig g plan that includes a photometric plan, luminaire schedule and cut
sheets for e. proposed fixture.
Res..onse: Lighting cut sheets have been added to Drawing Number C-2. There is only
e light and it is shielded from the residential area with the retaining wall and the
building parapet.
15. Comment: The title of the plan references WPO2015-33; however, County records
indicate that , P'O number is associated with Hillbrook VSMP. Provide the correct WPO
number th. is associated with this portion of the plan. A WPO for this portion of the site
shall b- .pproved prior to approval of the site plan.
s s onse: The WPO number has been updated to WPO 2015-30
16. Comment: On sheet 1 revise the title of the plan: "SDP2016-41 Farmington Country\
Club — East Nine Practice Facility — Mino ite Plan Amendment to SDP 2001-0005,
reference WPO—fill this in with correct O#. ; �S
Response: The title has been updated.
3040 Avemore Square Place • Charlottesville,VA 22911
Telephone(434) 984-2700 • Fax(434) 978-1444
Charlottesville•Lynchburg
Page 3 of 4
,ex 0„..-1- 4i) i\),,,,, cCk—
. 7-N \ c /Pe'NL11----1- -"-Lf4-A- C ct-^i''. --r-.) --S-
/ \1
/ ACSA Comment: ACSA approval is required prior to County approval of the plan.
/ i S99IACSA's comments attached.
Response: Noted
8. ACSA Comment: Provide fixture counts for the proposed building so the ACSA can
/ Iermine if a 1"tap will suffice for water service or if a large service tap and meter vault
will be required.
Response: Fixture counts have been submitted to ACSA.
19. ACSA CommConfirm if storm infrastrurn ex
ter main (including a water main
the crossing) is partctuof e this plshowanparallel. If so, protothefile ofistinge th
storm/water crossing is required.
ent:
Response: The storm infrastructure was installed as part of a previous plan to improve
the golf course.
We trust that the above responses and revised plans properly address the outstanding
items. If you have any questions,please contact me.
Sincerely,
WW4/ o fates, Inc.
b mberger
Project Manager
I
ir
/ `` 1.
7 ' \/
3040 Avemore Square Place • Charlottesville,VA 22911
Telephone(434) 984-2700 • Fax(434)978-1444
Charlottesville •Lynchburg
Page 4 of 4
Christopher Perez
From: Christopher Perez
Sent: Tuesday, October 11, 2016 9:58 AM
To: 'rumberger@wwassociates.net'
Subject: RE: Farmington CC Site Plan
Rob,
This photometric diagram is perfect !!!
In this instance you can avoid a full lighting photometric plan be it's a single light. I have discussed this with Margaret
and she agrees.
On the site plan provide the cut sheets for this light and label and depict the location of the light.
If you do seek to switch the lighting fixture to a full cutofffixture please assure the cutsheets w/these photometric
measurements are also included.
Thanks
Christopher P. Perez 1 Senior Planner
Department of Community Development 1County of Albemarle,Virginia
401 McIntire Road Charlottesville, VA 22902
434.296.5532 ext.3443
From: Rob Umberger [mailto:rumberger@wwassociates.net]
Sent:Tuesday, October 11, 2016 9:01 AM
To:Christopher Perez<cperez@albemarle.org>
Subject: RE: Farmington CC Site Plan
Chris,
Attached is the photometric cut sheet for this light. I will discuss the full cutoff light with Farmington. Keep in mind that
this light will be placed in a location that has shielding on the residential side by the retaining wall and the building
parapet itself.
Thanks,
Rob Umberger
Project Manager
g.l
A
./ !I;.
Asso(ixl l'S
Office Phone: 434.960.7589
Main: 434.984.2700
Fax: 434.978.1444
3040 Avemore Square Place
Charlottesville, VA 22911
rumberger@wwassociates.net
www.wwassociates.net
1
From:Christopher Perez [mailto:cperez@albemarle.org]
Sent: Monday, October 10, 2016 12:06 PM
To: Rob Umberger<rumberger@wwassociates.net>
Subject: RE: Farmington CC Site Plan
Rob,
Thanks for clarifying the location. Can you find/provide a standard cut sheet for this fixture's photometrics (see
attached example). Such information will help staff to guarantee no spillover will happen to the adjacent
residential Rural Area zoned parcels across Farmington Drive.
Also, while not required it would be nice ifyou could swap out this light fixture for one that is full cutoff being
this is the Rural Areas of the county.
Christopher P. Perez I Senior Planner
Department of Community Development (County of Albemarle,Virginia
4111 McIntire Road Charlottesville,VA 22902
434.296.5832 ext. 3443
From: Rob Umberger [mailto:rumberger@wwassociates.net]
Sent: Monday, October 10, 2016 10:15 AM
To:Christopher Perez<cperez@albemarle.org>
Subject: RE: Farmington CC Site Plan
Chris,
Attached is the plan with a note add for the location of the light. It will be below both the parapet roof and the
retaining wall top. Do you have a side view or some type of illustration of how the retaining wall looks next to
the building?
Thanks
Rob
Sent from my U.S. Cellularle Smartphone
Original message
From: Christopher Perez <cperez cr albemarle.org>
Date: 10/10/16 7:55 AM (GMT-05:00)
To: rumberger a,wwassociates.net
Subject: RE: Farmington CC Site Plan
Rob,
Yes, all lighting is required to be depicted on the site plan w/ a lighting plan regardless of the lumen levels.
Lights with lumens at or above 3,000 must be full cutoff. Lights below 3,000 lumens can be non-full cutoff;
however, all lighting must meet spillover requirements from the road. This is where the lighting plan w/
photometrics comes into play. Thus every site plan w/lighting is required to meet these requirements.
2
•
vie
I understand your question as it relates to a site plan w/ a single light under 3,000 lumens, I believe we can work
with you to avoid a full blown photometric plan and in this instance provide less.
I'll need to run this by Margaret for final sign off Prior to my having this conversation with her please depict
the location of the light on the site plan and send it over as a PDF.
Christopher P. Perez 1 Senior Planner
Department of Community Development County of Albemarle,Virginia
401 McIntire Road Charlottesville, VA 22902
434.296.5832 ext.3443
From: Rob Umberger [mailto:rumberger@wwassociates.net]
Sent: Friday, October 07, 2016 4:52 PM
To: Christopher Perez <cperez�cr�,albemarle.org>
Subject: Farmington CC Site Plan
Chris,
We are planning on submitting the revisions to the site plan early next week. One of your comments was on
lighting. There is only going to be one light on the building, near the exterior door. The cut sheet is attached.
The light will be shielded by the retaining wall and the parapet roof on the building and it is only a single 10.5w
LED bulb, 677 lumens. Do we really need a photometric plan for this one light?
Thanks,
Rob Umberger
Project Manager
giflO t,,-',i
s ‘;,•..
ASSOC! VI I `i
Office Phone: 434.960.7589
Main: 434.984.2700
3
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832 Fax (434) 972-4126
August 23, 2016
WW Associates, Inc
3040 Avemore Square Place
Charlottesville, VA 22911
RE: SDP2016-41 Farmington Country Club — East Nine Improvements - Minor Amendment
Dear Sir:
Your Minor Amendment application has been reviewed. In order for the amended site plan to be
approved the following revisions are required:
[32.5.2(n)] Existing and proposed improvements. As discussed at the 12-7-15 pre application
meeting, there is not an existing site plan covering this specific area of the site; rather, SDP2001-
55 is the closest known plan. Provide an additional sheet in this plan set similar to sheet 2/8 of
SDP2001-55, which depicts a detailed overview of the area these improvements are taking place
on.
2. [32.5.2(d)] Topography and proposed grading. Provide an existing conditions sheet, which
includes existing topography, including any critical slopes.
3. [32.5.2(b)] Information regarding proposed use. Provide the maximum amount of impervious
cover on this specific portion of the site.
4. [32.5.2(n)] Existing and proposed improvements. Provide widths of concrete aprons along the
front of the building.
5. [32.5.2(n)] Existing and proposed improvements. Provide the square footage of the building.
6. [32.5.1(c)] Dimensions. Provide height and width of the retain wall.
7. [32.5.1(c)] Dimensions. Provide the width of all areas of the pathway depicted on the plans.
Specifically the portion which flares out to 20 foot.
8. [32.5.2(a)] General information. Clearly depict and label the property line for the parcel nearest
Rte 250. Also, depict and label Rte 250.
9. [32.5.2(k)] Proposed sewer and drainage facilities. Indicate the direction of flow in all pipes
with arrows.
10. [32.5.2(a)] General information. Revise the setbacks noted on sheet 1 to include 75 foot setback
from existing public road. Also, remove the parking setbacks from the plan, as there are no
parking spaces proposed.
11. [Comment] Revise the note on sheet 3 of 4 which reads `Existing trees to remain to provide
screening protection during construction" to `Existing trees to remain to provide screening
protection."
12. [Comment] Provide deed book page reference number for all existing easements onsite,
specifically the relocated gas line of Charlottesville Gas.
13. [Comment] A WPO buffer is depicted on sheet 4. Provide a label for this buffer.
14. [32.6.2(k) & 4.171 Lighting. Is any outdoor lighting proposed with the site plan amendment? If
so, lighting (including building mounted fixtures) must be shown on a lighting plan that includes
a photometric plan, luminaire schedule and cut sheets for each proposed fixture.
15. [Comment] The title of the plan references WPO2015-33; however, County records indicate that
WPO number is associated with Hillbrook VSMP. Provide the correct WPO number that is
associated with this portion of the plan. A WPO for this portion of the site shall be approved
prior to approval of the site plan.
16. [Comment] On sheet 1 revise the title of the plan: "SDP2016-41 Farmington Country Club -
East Nine Practice Facility - Minor Site Plan Amendment to SDP2001-00055, reference WPO fill
this in w/ correct WPO #".
17. [Comment] ACSA approval is required prior to County approval of the plan. See ACSA's
comments attached.
ACSA — Alex Morrison
See attached emailed comments.
Building Inspections — Jay Schlothauer
No objections
Engineering —Matthew Wentland
No objections
ARB — Margaret Maliszewski
No objections
Fire and Rescue — Robbie Gilmer
No objections
Virginia Dept of Health - Josh Kirtley
Approval of septic received.
Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle.
The Code is kept up to date by the County Attorney's office. The Code may found on the County
Attorney's website which may be found under "Departments and Services" at Albemarle.org.
In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to
submit a revised final site plan to address all of the requirements within six (6) months after the date
of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If
you have any questions about the comments please feel free to contact me.
Sincerely,
Christopher P. Perez
Senior Planner
Planning Division
Christopher Perez
From: Alexander Morrison <amorrison@serviceauthority.org>
Sent: Monday, August 22, 2016 1:42 PM
To: Christopher Perez
Subject: RE: SDP201600041: Famington Country Club - Minor Amendment
Chris,
They can e-mail me the information so I can look at the meter size. Either way there will be a revision. I can comment on
meter size and what revisions I need once I see the fixture count so they can show it on their next submission.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(0) 434-977-4511 Ext. 116
(C) 434-981-5577
(F) 434-979-0698
From: Christopher Perez [mailto:cperez@albemarle.org]
Sent: Monday, August 22, 2016 1:32 PM
To: Alexander Morrison
Subject: RE: SDP201600041: Famington Country Club - Minor Amendment
Alex,
SDP201600041 - Farmington Country Club - Minor Amendment
I received your comments. I have questions. Does any of your comments require changes/ modifications to the
site plan under review OR can they just provide the information you requested via email?
I'm just trying to shore up your comments and understand if they are required to revise the plans per your
comments.
From: Alexander Morrison [mailto:amorrison@serviceauthority.org]
Sent: Monday, August 22, 2016 1:27 PM
To: Christopher Perez <cperez@albemarle.org>
Subject: SDP201600041: Famington Country Club - Minor Amendment
Chris,
I have reviewed the resubmittal for the above referenced project and have the following comments:
Provide fixture counts for the proposed building so the ACSA can determine if a 1" tap will suffice for water
service or if a large service tap and meter vault will be required.
Confirm if the storm infrastructure shown parallel to the existing water main (including a water main crossing) is
part of this plan. If so, a profile of the storm/water crossing is required.
Let me know if you have any questions.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(0) 434-977-4511 Ext. 116
(C) 434-981-5577
(F) 434-979-0698
'Christopher Perez
From: Christopher Perez
Sent: Tuesday, August 02, 2016 7:48 AM
To: 'rum Berger@wwassociates.net'
Subject: RE: Farmington Site Plan Amendment
Rob,
See my responses below in red.
From: Rob Umberger [mailto:rumberger@wwassociates.net]
Sent: Monday,August 01, 2016 2:28 PM
To:Christopher Perez<cperez@albemarle.org>
Subject: FW: Farmington Site Plan Amendment
Chris,
We adjusted the plans to show the trees as Margaret requested and she is ok with the changes. See attached.
I think that the health department has issued a permit. I have a call into ACSA. 7_ s-76'
I have yet to receive VDH comments. Once received they shall be forwarded. ✓pe-'`'
I have yet to receive ACSA comments. Once received they shall be forwarded.
I need to get you revised plans based on Margaret's comments. Is there anything else that has been commented
on? Are we ready for approval?
As of today I have yet to review your plans, I've got 5 plans in the stack before I get to yours. If you would like
you may send me 5 revised sets which address Margaret's comments. I'll use this set to conduct my review and
hopefully approve. If that's not how you wish to proceed, I hope to conduct my initial review before Aug 9th
Please understand that our office is currently experiencing a surge in applications and we're down a number of
reviewers.
Notably I'm awaiting approvals from the/
and ACSA. Neither has provided comments yet.
Thanks,
Rob Umberger
Project Manager
MENriontits
stm,.
Assoc'i/ rE s
Office Phone: 434.960.7589
Main: 434.984.2700
Fax: 434.978.1444
3040 Avemore Square Place
Charlottesville, VA 22911
rumberger@wwassociates.net
www.wwassociates.net
www.facebook.com/WWAssociatesInc
1
.. ........................
From: Margaret Maliszewski [mailto:MMaliszewski@albemarle.org]
Sent: Monday, August 01, 2016 2:17 PM
To: rumberger@wwassociates.net
Subject: RE: Farmington Site Plan Amendment
This works for me. Thanks.
From: Rob Umberger [mailto:rumberger@wwassociates.net]
Sent:Thursday,July 28, 2016 3:57 PM
To: Margaret Maliszewski<MMaliszewski@albemarle.org>
Cc: Christopher Perez<cperez@albemarle.org>
Subject: Farmington Site Plan Amendment
Margaret,
I sent the survey crew out to identify the trees along Farmington Drive and the railroad as we discussed. The individual
trees are now shown on the plan.
The trees to remain are now noted and grading has been adjusted to allow for protecting the trees.
Is this what you need? Anything else? We will give hard copies to Chris if this works.
Thanks, I appreciate your help on this.
Rob Umberger