Loading...
HomeMy WebLinkAboutSDP201600074 Correspondence Initial Site Plan 2016-12-09hAM AND ASSOCIATES INC, REFLECTING TOMORROW December 09, 2016 County of Albemarle 401 McIntire Road Charlottesville, VA 22902 RE: Response to SDP Pre -application & ARB Comments Timberland Park Apartments Balzer Project No: 34160034 County Project No: SDP2016-053 This letter serves as our written responses to the County comments on the subject: Planning — Megan Yaniglos 1. [32.4.1.3(a)] It appears that the maximum setback for the buildings does not apply due to the existing ACSA easement. However, this will need to be determined during initial site plan due to comments from ACSA regarding the upgrade of the sewer line. Due to the existing grade of the site and the existing location of sanitary we cannot move these buildings closer. We have coordinated with ACSA on the needed sanitary work and this is reflected in these plans. 2. [32.4.1.3(b)] Buildings over 40 feet or t1i, 3rd story require foot step back p,. code section 4.19. Step back has been reflected in plans. 3. [32.4.1.3(d)] The steep slopes shown on the plan do not appear to match those slopes that are shown on the County GIS. The County Engineer will need to determine if the slopes surveyed showing less than 25% are more accurate than the GIS. A to scale exhibit showing the difference in slopes (GIS and survey) would ho k -Infill Exhibit has been previously provided per email. It has also been provided with this submittal. The exhibit shows the limits of existing grades based on 25% slopes or greater. These grades we field surveyed and areas of steep characteristics were surveyed in greater quantity to make sure we identified all PLANNERS ' ARCHITECTS ' ENGINEERS ' SURVEYORS ROANOKE 'RICHMOND 'NEW RIVER VALLEY SHENANDOAH VALLEY 1561 Commerce Road, Suite 401 ' Verona, Virginia 24482 ' (540) 248-3220 • FAX (540) 248-3221 Response to Comments Timberland Park Apartments Page 2 of S steep slopes accurately. On the plans we have not only shown areas that were identified on the County GIS but also those that we identified with field survey. Also, it should be noted that the area labeled "Preserved" on the GIS was actually surveyed as being larger based on field topo then what was recorded on GIS, we included this additional area as "Preserved" for your records. 4. _�..._.�... ��..�. -a3cgent is labe cu, — additional information is provided. Clarify this easement, and if it has been recorded provide the deed book and page number. DB & PG provided on plans. 5. [32.7.2.3] A sidewalk should be provided along Old Lynchburg Road. Sidewalk added. 6. [4.16] Two tot lots need to be provided as described under this section of the Zoning Ordinance (size and equipment). If an exception from this requirement is desired, provide a justification with the initial site plan for review. Tot Lots added and a note of what should be included. 7. [32.4.1.3(q)] Portions of the site are within the Dam Break Inundation Zone and will be forwarded to DCR for review when the initial site plan is submitted. Noted. Dam break zone is shown on C2 and C5. VDOT - Adam Moore, P.E. ,rn IanP triaht anri IPftl ar^---4-" Turn lane analysis and sight distance has been coordinated with VDOT. These exhibits were provided prior in email as well as with this submittal. En2ineerin$! - Matt Wentland 1. Grading in some areas appears to direct the runoff to areas with no inlets and towards buildings. All inlets, flumes, foundation inlets and ditches and grading elevations are now provided on plans. 2. The grading should be at least 5' from the property line or a temporary grading easement should be acquired. Grading has been adjusted to be 5' from property line. 3. Retaining wall plans may be needed to show wall construction will not encroach on preserved slopes and neighboring property. Due to further coordination with ARB and ACSA and VDOT as well as these comments the plans have been taken to a more complete stage of development. With that said, retaining walls have been changed slightly or added or some removed. If there are any walls in particular that are of concern please let us know and we can provide further detail. We have provided a typical wall detail on C13 as well as a more in depth grading plan. 4. r- uveae a prop ,ic u, the entrance. Profile provided on C3. 5. Although the storm system is c011ceNLuQ1, IL app..,l ,More controls may be necessary to prevent the flow depths from topping the curbs and the spreads from going too far outside of PLANNERS ' ARCHITECTS ' ENGINEERS ' SURVEYORS ROANOKE 'RICHMOND 'NEW RIVER VALLEY ' SHENANDOAH VALLEY 1561 Commerce Road, Suite 401 ' Verona, Virginia 24482 ' (540) 248-3220 • FAX (540) 248-3221 Response to Comments Timberland Park Apartments Page 3 of S Further development of storm system has been performed and additional structures have been added. Calculations have been provided with this submittal. ARB — Margaret Maliszewski Before ARB Meeting Comments 1. Plants shown in the 10' landscape buffer may need to be revised to satisfy ARB conditions of approval. Plants revised. 2. Buildings are not oriented parallel to the EC, as is required by the guidelines. Reduced visibility from the EC can reduce the importance of orientation in this case. Screening and vegetation has been added to reduce this affect. 3. If the BMP is visible from the EC, the engineered feature will need to be revised to look like a landscape feature that is visually integrated into the surrounding landscape. The lower BMP features will consist of a grassed weir which will integrate with the surroundings. The upper BMP will have structural components such as a riser and dome grate top, however due to elevation, distance from EC, and them being 1' lower than the berm this should not be visible from the EC. 4. F-., ruiuCilnes state that "site grading should maintain the basic relationship of the site to surrounding conditions by limiting the use of retaining walls and sloping the terrain through the use of smooth, rounded land forms that blend with the existing terrain. Steep cut or fill sections are generally unacceptable." The proposal does not appear to meet this guideline. Reduced visibility from the EC can reduce the emphasis placed on this guideline in this case. Noted. 5. It would be helpful to have the following information to facilitate ARB review of the proposal: a. Site sections to clarify anticipated visibility of the development from the 1-64 Entrance Corridor. Provided. b. Include on the site plans the location of the 164 edge of pavement. Provided. c. Include on the grading plan the topography in the 164 right-of-way. Provided. ARB Meeting Comments 1. Provide for review samples of the proposed building materials and colors Provided at meeting for review. Please let us know if you need further samples. �. Haa trees at the norin ena or Isuiming 44.. Trees added. 3. Add the standard window glass note to the d, %,mteCLU1 dl plans. Window glass in the Entrance Corridors shall meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. Specifications on the proposed window glass should be submitted with the application for final review. Note will be added to Arch plans. 4. Show locations of proposed equipment and show how visibility will be eliminated Mechanical units now shown and screening shown on LA plan. As discussed, further foundation plantings will be done, however this general theme will remain, 36" tall PLANNERS ' ARCHITECTS ' ENGINEERS ' SURVEYORS ROANOKE 'RICHMOND 'NEW RIVER VALLEY ' SHENANDOAH VALLEY 1561 Commerce Road, Suite 401 ' Verona, Virginia 24482 ' (540) 248-3220 • FAX (540) 248-3221 Response to Comments Timberland Park Apartments Page 4 of 5 evergreen shrubs around the mechanical units. 5. Add the standard mechanical equipment note to the architectural drawings. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." Note will be added to Arch plans. 6. Identify on the lighting nlan the cnlnr nronnsed fnr the nnles and fixtures. Rrnn7e is recommended Note added to Lighting Plan that Dark Bronze Textured finish must be used for all fixtures. I. r`CuuLC pole light heir,, Ir LU 20 WWI, iiiomiiiuiii. Pole height reduced to 20'. 8. Add the standard lighting note to the plan. "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle." Note added to Lighting plan. 9. Include a complete landscape plan and c�hor4l+IP with the next suhmittal. Show planting consistently throughout the plan set. Plan and schedule added with required landscaping. 10. r -i UVIuc d i nix of large tree species along the L.. -)[UC U1 L[ IC �,ILC. intersperse ornamental trees among the large shade trees. Mix of large trees added and ornamentals. 11. Trees along Old Lynchburg Road shall be a minimum of 2%" caliper at planting. Noted. 12. Provide perimeter parking lot trees, 40' on center, 2Y2" caliper at planting. Added. 13. Add trees in the open area west of Building #3 to help soften the appearance of the wall. Trees added. 14. Add the standard plant health note to the plan. "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trap-, rhatl be pruned minimally and only to support the overall health of the plant." Note added to landscape plan. Fire Rescue — Robbie Gilmer 1. Buildings over 30' in height regL" 6' access aisi 'gat is no more than 30' from the buildir As discussed, height of 311 floor will be at 28'6". Also, an auto turn exhibit had previously been provided via email based on Counties largest truck for review of maneuverability of site. ACSA — Alex Morrison 1. The sewer main along the frontage of the orooerty will need to be relocated to achieve the reauired cover at the nronosed entrance Coordination has been made with ACSA and other developer to allow for adequate cover and modification of downstream inverts. 2. Show fire hydrants and FDC', Hydrants and FDC's added. Also a Fire Flow Model has been performed and provided with this submittal. PLANNERS 'ARCHITECTS ' ENGINEERS ' SURVEYORS ROANOKE 'RICHMOND 'NEW RIVER VALLEY SHENANDOAH VALLEY 1561 Commerce Road, Suite 401 ' Verona, Virginia 24482 ' (540) 248-3220 • FAX (540) 248-3221 Response to Comments Timberland Park Apartments Page S of S Please do not hesitate to contact us if you have any questions. Sincerely, BALZER AND ASSOCIATES, INC. D. Kent O'Donohue, LA Project Designer PLANNERS ' ARCHITECTS ' ENGINEERS ' SURVEYORS ROANOKE 'RICHMOND 'NEW RIVER VALLEY ' SHENANDOAH VALLEY 1561 Commerce Road, Suite 401 ' Verona, Virginia 24482 ' (540) 248-3220 • FAX (540) 248-3221