Loading...
HomeMy WebLinkAboutSDP201600070 Action Letter 2016-12-13COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 MEMORANDUM TO: JT Newberry FROM: Margaret Maliszewski RE: ARB-2016-70: Springhill Townplace DATE: December 13, 2016 On August 15, 2016 the ARB completed a review of the above -noted request, which included the review of both an original plan and a revised plan. Subsequently, the applicant submitted an Initial Site Plan to the County. Because the Initial Plan is consistent with the plan previously reviewed by the ARB, another ARB review is not needed at this time, and I am forwarding the ARB's preliminary comments to be used as Initial Site Plan comments. • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c (2), (3) and (5): A Certificate of Appropriateness is required prior to final site plan approval. The following items shall be addressed in the final site plan submittal: 1. Provide material and color samples for review. 2. Provide a mix of shrubs in an irregular pattern to screen the dumpster from the EC street. 3. Provide a dumpster screen detail in the site plan. Shift the parcel line or shift the dumpster location so that the dumpster is entirely on the hotel parcel after subdivision. 4. Clarify on the drawings the location and appearance of the elevator penthouse and any associated equipment. 5. If existing trees are proposed to remain on -site or off -site in the landscape easement after construction, indicate their location, size and species on the plan. 6. Add trees 2'/2" caliper at planting, 40' on center, along the southern side of the southern access drive. 7. Revise the plan to define the planting area for the trees to be added along the EC frontage. 8. Increase the depth of the planting area for trees on the south side of the parking lot or clarify how the trees will thrive in the minimal planting area provided. 9. Intersperse trees along the north side of the building, particularly at the east end, and place them to coordinate with the architectural design. 10. Identify on the plan the material, manufacturer and color proposed for the retaining walls. 11. Include the standard window glass note on the architectural drawings: "Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%." Provide specs and a glass sample for review. 12. Add the standard mechanical equipment note to the architectural drawings: "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." ***Additional requirements: 1) the landscape plan shall reflect the plant size requirements in the Entrance Corridor Design Guidelines, and 2) the final site plan submittal shall include all items on the ARB Final Site Plan checklist. Regarding recommendations on the plan as it relates to the guidelines: o None. • Regarding recommended conditions of initial plan approval: o None. • Regarding conditions to be satisfied prior to issuance of a grading permit: o None.