HomeMy WebLinkAboutARB201600143 Certificate of Appropriateness 2016-12-21COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832 Fax (434) 972-4126
December 21, 2016
Brittany Lewis
HFA
1705 S. Walton Blvd., Suite 3
Bentonville, AR 72712
RE: ARB -2016-143: Walmart Signs (TMP 04500-00-00-068D5)
Dear Ms. Lewis,
We have reviewed your request for the above -noted signs and have approved the design as illustrated in the attached
drawings. You may consider this letter your Certificate of Appropriateness. This approval is predicated on the fact that the
design and materials, as proposed and illustrated, will be used. The acceptance of approval implies that the applicant has
agreed to execute the design as indicated on the submittal items presented. Any changes in the approved design will require
a new application and additional review.
PLEASE NOTE: A CHECKED BOX MEANS THESE CONDITIONS APPLY TO YOUR SIGN APPROVAL
®
The level of illumination produced by the LED lights shall not exceed the level of illumination produced by a single stroke of
30 milliamp neon.
®
This ARB approval is only one approval required prior to installing a sign. An approved sign permit is also required. Please
do not proceed with the construction or installation of your sign until you have received your signed permit. If you have
questions about the status of a sign permit application, please contact the permit intake staff at 296-5832.
If you have any questions concerning this action, please feel free to contact me.
Sincerely,
Amanda Burbage
Senior Planner
434-296-5832 x3023
aburbage@albemarle.org
cc: Walmart Real Estate Business Trust, 2001 SE 101 St., Bentonville, AR 72716
CAP
PAINT TAGS SHOWN FOR
REFERENCE. GC IS ONLY TO
TOUCH-UP PAINT AT AREAS
AFFECTED BY INSTALLATION
OF NEW SIGNAGE.
DO NOT PAINT INTREGALLY
COLORED BLOCK, QUICK BRICK,
OR CONCRETE WALL CAP.
CAP
P92 PAINT TAGS SHOWN FOR
REFERENCE. GC IS ONLY TO
TOUCH-UP PAINT AT AREAS
AFFECTED BY INSTALLATION
OF NEW SIGNAGE.
DO NOT PAINT INTREGALLY
COLORED BLOCK, QUICK BRICK,
OR CONCRETE WALL CAP.
DOOR
RIGHT VESTIBULE ELEVATION LEFT VESTIBULE ELEVATION
6 1" = 20'-0" 5 1" = 20'-0"
I I I I I 1
CAP CAP CAP
P92 P92 P92
P89
DOOR
LEFT ELEVATION
4 1„ = 20'-0"
PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY
REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK,
TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP.
AFFECTED BY INSTALLATION
OF NEW SIGNAGE.
3
I
CAP
P92 P92
SHEET NOTES
-REVISED NOTE #1
-REVISED NOTE #5
-REVISED NOTE #7
-ADDED NOTE #8 AND
RENUMBERED #9420
DEMOLITION NOTES
-REMOVED NOTE #2 AND
RENUMBERED #346
-REVISED NOTE #2
DOOR DOOR
PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY
REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK,
REAR ELEVATION
3 TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP.
AFFECTED BY INSTALLATION
1" = 20'-0 OF NEW SIGNAGE.
I I I I
CAP I I I
1 � I
DOORS
I I I I I
I I I I I
DOOR DOORS
PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY GARDEN CENTER METAL
REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK, CANOPY AND FENCE NOT
RIGHT ELEVATION
TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP. SHOWN FOR CLARITY
(:2 AFFECTED BY INSTALLATION OF
1" = 20'-0" NEW SIGNAGE.
1 3
L 53'-2" t
Q Q
F— EXISTING I I ,
FRONT ELEVATION
1 1 = 20'-0"
IVCVV JIVI17 VCIV I CFNL;L✓
HORIZONTALLY OVER
DOORS, REF 4-A2.1
7
75'-n"
SOFFIT
— NEW SIGN CENTERED
HORIZONTALLY OVER
DOORS, REF 3-A2.1
DOOR DOOR
CAP
HARRISON FRENCH
& ASSOCIATES, LTD
1705 S. Walton Blvd., Suite 3
Bentonville, Arkansas 72712
t479.273.7780
f 888.520.9685
www.hfa-ae.com
LUD
SLB
U)
o i 'zwoi aZL"Zr
w
W
p �rwF=wURZzrnr
g=2 www E3. z
PROTO TYPE: 143 Non Proto SC
uw.UOp2wU
O
w
LL
W. ow
iii>�zz¢�W. ow
Z
O_
�wui�¢oQ° �wur.wM<
¢r.-lw !g 70wr 02p
3m�a�ozzW=zOz
~
ZIU-iw
c. No. 016472
^0o��z=��zo
Udo`. wma4ouria�znwi
D
pcoi�9wOmwNaWWQOR3
y¢¢ZFHpH.�owaDl_w
0owQ�ww=U
o0(1a<-
J
W
0
O
w
00 W
J4
U co
w W
�0
U
O 0_
0
� oc
�Uo&
wz
F-- W
O
0 O �
Gij
O N
ry o
Q w
W
= m
UZ
0
----
ISSUE BLOCK
1 1PR 1 1 12/09/16
CHECKED BY:
SLB
DRAWN BY:
LSB
DOCUMENT DATE:
11/2/16
PROTO TYPE: 143 Non Proto SC
PROTO CYCLE:
08/26/16
DEC 12 2016
EXTERIOR
ELEVATIONS
SHEET:
A2
•,.1
r-:
`}
EByy LTJ
BRE -CH to
5:
c. No. 016472
DEC 12 2016
EXTERIOR
ELEVATIONS
SHEET:
A2
REFER TO SIGNAGE GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS.
DRILL HOLE AND FEED
WHIP THROUGH WALL
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF CONDUIT
1/2" FLEX CONDUIT 20'
LONG SUPPLIED IN SIGN
CAN- CONTINUOUS.
THROUGH ENTIRE WALL —
PVC SPACER TO PREVENT
COMPRESSION OF METAL PANEL,
3/4" OUTER DIAMETER AND
5/8" INSIDE DIAMETER TYP
ABANDON EXISTING HOLES IN SIGN
CAN AND DRILL NEW HOLES 2"
FROM EXISTING ATTACHMENTS.
HOLE SHOULD BE 3/4" DIAMETER
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF SPACER
3"NEOPRENE/SS BONDED WASHER
AND NUT IN BED OF CONTINUOUS
MULTI-COMPONENT SEALANT
REF BLDG EL
BO SIGNAGE
SIGN CAN WITH
.080 ALUMINUM BACKING
1/2" ALL -THREAD CUT TO WITHIN 1/4"
OF NUT AND GRIND END SMOOTH
WALMART SIGN
Viia. = 1'-0"
ATTAC
EXISTING ROOFING
SYSTEM
TO JUNCTION BOX,
REF ELECTRICAL
EXISTING METAL ANGLE,
REF STRUC. IF ANGLE
SPACING IS GREATER
THAN 4'4" OC, PROVIDE
2X TIE BETWEEN INSIDE
AND OUTSIDE BLOCKING
EXISTING METAL
STUDS, REF STRUC
EXISTING METAL
PANEL
NOTE:
LOCATE ALL -THREADS PER SIGN
ATTACHMENT TEMPLATE.
BLOCKING ONLY REQUIRED AT
ATTACHMENT POINTS. GC TO
COORDINATE WITH SIGN
SHOP/INSTALLER FOR LOCATIONS
SECTION 2A IN PLAN -NTS
HMENT AT METAL WALL PANEL
REFER TO SIGNAGE GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS
MOUNTING HOLE
PATTERNS FOR NON -
ILLUMINATED SIGN
INSTALLATION
PLASTIC MOUNT FOR
ALL -THREAD STUD TYP
INSTALL 1/8" DIAALL-
THREAD STUDS INTO
PLASTIC MOUNTS
m
w
3/8" DIA HOLE FILLED WITH
ADHESIVE SEALANT
PLASTIC NON -
ILLUMINATED
CHANNEL LETTER
"ADHESIVE SEALANT" IS TO BE
PRODUCT LN -950 BY LIQUID
NAILS OR SIMILAR
POLYURETHANE
CONSTRUCTION ADHESIVE
MEETING ASTM D3498 AND C557
STANDARDS, EXTERIOR
APPLICATION, WEATHER
RESISTANT, LOW VOC, WITH A
MINIMUM SHEAR STRENGTH OF
250 PSI
HMENT AT EIFS AND
REPLACE EXISTING EIFS AS
REQUIRED FOR NEW 5/8"
PLYWOOD SHEATHING.
RESURFACE EXISTING EIFS
TO REMAIN, REF SPECS
PRIOR TO PERFORMING THIS
WORK, VERIFY EXISTING
SUBSTRATE MATERIAL. IF
EXISTING SUBSTRATE IS CMU
OR PLYWOOD (5/8" OR
THICKER), SUBSTRATE
REPLACEMENT IS NOT REQ'D
REPLACE EXISTING
SHEATHING AT SIGN
WITH 5/8" EXTERIOR
PLYWOOD SHEATHING.
INSTALL NEW EIFS AS
REQUIRED. MATCH
ADJACENT TEXTURE
AND FINISH
EXISTING FRAMING
SIGN ATTAC
1 1/2" = 1'-0"
EXISTING METAL
PANEL
TREATED 2x4 BLOCKS
EACH SIDE OF ANGLE
ATTACH WITH (2) PAFS
SPLICE BLOCKING
AS REQD AT ANGLE
LEG
(2) 3" WOOD SCREW
AT EACH 2x4 BLOCK
EXISTING METAL
ANGLE, REF STRUC
ATTACH NEW
BLOCKING WITH
(2) 1-1/2' WOOD
SCREWS EACH END
(PRE -DRILL HOLES
IN ANGLE)
METAL STUD WALL
FULL BED OF MULTI-
COMPONENT SEALANT AT
AT QUIK BRICK WALL
PERIMETER OF CONDUIT
X
t...../............._.......... ..............
BY SIGN INSTALLER
1 112" = 1'-0"
Y
FLEX CONDUIT SUPPLIED
WITH LETTERS
CONTINUOUS THROUGH
AT QUIK BRICK WALL
o
X
10
ENTIRE PARAPET BY SIGN
1 112" = 1'-0"
z�~QgL-w cl w
-CUSTOM MANUAL MATCH
1
INSTALLER
128
NOTES FOR ADDITIONAL
1
B1 BLACK 6 4 1
1
REQUIREMENTS.
1
Y3 DEEP GOLD - 48 1
r/
G2 NEW GREEN - 18 -
-
ONE GALLON #B54T00104
MOUNTING HOLE PATTERNS FOR
UI TRADECP #796999993
INSTALL LETTER BACK
INSTALLATION
PRIOR TO INSTALLATION
PLASTIC MOUNT FOR
BY SIGN INSTALLER
INSTALL 1/8" DIA ALL -
THREAD STUDS INTO
_..................,...
INDIVIDUAL PLASTIC
PRIOR TO SIGN
ILLUMINATED
INSTALLATION, TYP
3/8" DIA HOLE FILLED WITH
CHANNEL LETTERS BY
-_1 ..-............. __....._..._.._.._.._...'_:.:::
SIGN SUPPLIER
ALL -THREAD STUD WITH
._.....__......_....__.
------ _........ _... m.._....
INSTALL LETTER FACES
TO WALL ATTACHMENT, w
W/ SET SCREWS, TYP
TYP
BY SIGN INSTALLER
PLASTIC NOW
ILLUMINATED
CHANNEL LETTER
,ADHESIVE SEALANT" IS TO BE
PRODUCT LN -950 BY LIQUID
NAILS OR SIMILAR
POLYURETHANE CONSTRUCTION
ADHESIVE, MEETING ASTM D3498
AND C557 STANDARDS,
EXTERIOR APPLICATION, '
WEATHER RESISTANT, LOW VOC,
WITH A MINIMUM SHEAR
STRENGTH OF 250 PSI
HMENT AT QUIK-BRIK WALL
SEALANT ALL AROUND BY BUILDING
GENERAL CONTRACTOR
CONTINUOUS UNISTRUT PROVIDED BY
GENERAL CONTRACTOR. ATTACH AT 48"
OC WITH 6x6 STEEL PLATE WITH (4) 1/2"
MASONRY EXPANSION ANCHORS. SET
PLATE IN FULL BED OF SEALANT. NOTE,
UNISTRUT MAY BE ABOVE OR BELOW
WIRE PENETRATION
4" X 4" JUNCTION BOX. ATTACH
TO UNISTRUT BY BUILDING
GENERAL CONTRACTOR
LOCATE CONDUIT PENETRATION
4'-0" MAX FROM UNISTRUT.
PROVIDE ONLY ONE ROOF
PENETRATION FOR ALL WHIPS.
LOCATE IMPACT ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
EXISTING QUIK-BRIK
SIGN ATTAC
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE
IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL
PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING
HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS.
ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
SIGN MOUNTING_
LOCATION (TYP) FIELD ELECTRICAL PENETRATIONS (TYP)
FIELD VERIFY EXACT LOCATIONS
VERIFY EXACT LOCATIONS a
NOTE:Q u
p ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR k` ""
MINIMUM OF 8" ABOVE DECK
15'- 4"
THE LEVEL OF ILLUMINATION 3'- 10 1/2" 10'- 7 1/2"
PROVIDED BY THE LED LIGHTS
WILL NOT EXCEED THE _ WHITE PLASTIC LETTERS
ILLUMINATION PRODUCED r —
BY A SINGLE STROKE OF
30 MILLIAMP (MA) NEON.
lc:k�ull
L—s -- — J
66.76 SF
PLASTIC CHARACTERS INTERNALLY
MATCH SW #6904 10 ILLUMINATED
'GUSTO GOLD' 1 TYP
2'-6 PICKUP SIGNAGE
9 1 /4" = 1'-0"
25'- 5 3/8"
00 = ° ii
Oiery
o'u.�.. e Pho >.� lu"i a _
i� ......... ..... ....._... _.._ ...._._ ... _ . _ __ _. _
70.30 S.F.
5
TYP
A2.1
24" GROCERY & PHARMACY SIGNAGE
17'-5"
G) p
'<V
N o c o 0 0 0 0, oc.:: - °- „o . o 0 0 0 0
5 46.44 SQ.FT.
TYP
A2.1
24" HOME & LIVING SIGNAGE
1/4
19'- 1 3/8"
w -u,' n
F x.
,i
41.02 sq.ft
7
TYP
A2.1
24" LAWN &GARDEN SIGNAGE
DO NOT PAINT EXISTING Mf,Q,_,v4u\
LSIGN
E SIGN
DONE BY
ONTRACTOR
WALMART PYLON
6 3/16" = V-0"
EXISTING CABINET TO
REMAIN, PAINT TRIM AND
CABINET "DURANODIC
BRONZE" -REFERENCE
TABLE
EXISTING BRAND FACE TO
REMAIN
SHERWIN-WILLIAMS DURANODIC
AT QUIK BRICK WALL
PICKUP
SIGNAGE ATTACHMEN
10
o
w g aw5UO
1 112" = 1'-0"
z�~QgL-w cl w
-CUSTOM MANUAL MATCH
REFER TO SIGNAGE GENERAL _
BAC COLORANT: OZ 32 64
128
NOTES FOR ADDITIONAL
1
B1 BLACK 6 4 1
1
REQUIREMENTS.
1
Y3 DEEP GOLD - 48 1
1
G2 NEW GREEN - 18 -
-
ONE GALLON #B54T00104
MOUNTING HOLE PATTERNS FOR
UI TRADECP #796999993
NON -ILLUMINATED SIGN
INSTALLATION
PLASTIC MOUNT FOR
ALL -THREAD STUD, TYP
INSTALL 1/8" DIA ALL -
THREAD STUDS INTO
PLASTIC MOUNTS
PRIOR TO SIGN
INSTALLATION, TYP
3/8" DIA HOLE FILLED WITH
ADHESIVE SEALANT. COAT
ALL -THREAD STUD WITH
ADHESIVE SEALANT PRIOR c)
TO WALL ATTACHMENT, w
TYP
PLASTIC NOW
ILLUMINATED
CHANNEL LETTER
,ADHESIVE SEALANT" IS TO BE
PRODUCT LN -950 BY LIQUID
NAILS OR SIMILAR
POLYURETHANE CONSTRUCTION
ADHESIVE, MEETING ASTM D3498
AND C557 STANDARDS,
EXTERIOR APPLICATION, '
WEATHER RESISTANT, LOW VOC,
WITH A MINIMUM SHEAR
STRENGTH OF 250 PSI
HMENT AT QUIK-BRIK WALL
SEALANT ALL AROUND BY BUILDING
GENERAL CONTRACTOR
CONTINUOUS UNISTRUT PROVIDED BY
GENERAL CONTRACTOR. ATTACH AT 48"
OC WITH 6x6 STEEL PLATE WITH (4) 1/2"
MASONRY EXPANSION ANCHORS. SET
PLATE IN FULL BED OF SEALANT. NOTE,
UNISTRUT MAY BE ABOVE OR BELOW
WIRE PENETRATION
4" X 4" JUNCTION BOX. ATTACH
TO UNISTRUT BY BUILDING
GENERAL CONTRACTOR
LOCATE CONDUIT PENETRATION
4'-0" MAX FROM UNISTRUT.
PROVIDE ONLY ONE ROOF
PENETRATION FOR ALL WHIPS.
LOCATE IMPACT ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
EXISTING QUIK-BRIK
SIGN ATTAC
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE
IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL
PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING
HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS.
ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
SIGN MOUNTING_
LOCATION (TYP) FIELD ELECTRICAL PENETRATIONS (TYP)
FIELD VERIFY EXACT LOCATIONS
VERIFY EXACT LOCATIONS a
NOTE:Q u
p ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR k` ""
MINIMUM OF 8" ABOVE DECK
15'- 4"
THE LEVEL OF ILLUMINATION 3'- 10 1/2" 10'- 7 1/2"
PROVIDED BY THE LED LIGHTS
WILL NOT EXCEED THE _ WHITE PLASTIC LETTERS
ILLUMINATION PRODUCED r —
BY A SINGLE STROKE OF
30 MILLIAMP (MA) NEON.
lc:k�ull
L—s -- — J
66.76 SF
PLASTIC CHARACTERS INTERNALLY
MATCH SW #6904 10 ILLUMINATED
'GUSTO GOLD' 1 TYP
2'-6 PICKUP SIGNAGE
9 1 /4" = 1'-0"
25'- 5 3/8"
00 = ° ii
Oiery
o'u.�.. e Pho >.� lu"i a _
i� ......... ..... ....._... _.._ ...._._ ... _ . _ __ _. _
70.30 S.F.
5
TYP
A2.1
24" GROCERY & PHARMACY SIGNAGE
17'-5"
G) p
'<V
N o c o 0 0 0 0, oc.:: - °- „o . o 0 0 0 0
5 46.44 SQ.FT.
TYP
A2.1
24" HOME & LIVING SIGNAGE
1/4
19'- 1 3/8"
w -u,' n
F x.
,i
41.02 sq.ft
7
TYP
A2.1
24" LAWN &GARDEN SIGNAGE
DO NOT PAINT EXISTING Mf,Q,_,v4u\
LSIGN
E SIGN
DONE BY
ONTRACTOR
WALMART PYLON
6 3/16" = V-0"
EXISTING CABINET TO
REMAIN, PAINT TRIM AND
CABINET "DURANODIC
BRONZE" -REFERENCE
TABLE
EXISTING BRAND FACE TO
REMAIN
SHERWIN-WILLIAMS DURANODIC
ww >; ('6
BRONZE/ ORDER NUMBER 7248-
9 L lzww (T WZ (D
O zwU. Ozoo
Wo�W��Zz�nF
0044642
o
w g aw5UO
- BRONZE MATCH
z�~QgL-w cl w
-CUSTOM MANUAL MATCH
aW��=a>
WI
BAC COLORANT: OZ 32 64
128
W1 WHITE 43
1
B1 BLACK 6 4 1
1
R2 MAROON - 19 -
1
Y3 DEEP GOLD - 48 1
1
G2 NEW GREEN - 18 -
-
ONE GALLON #B54T00104
UI TRADECP #796999993
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE
IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL
PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING
HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS.
ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
ELECTRICAL PENETRATION (TYP)
FIELD VERIFY EXACT LOCATIONS °
®
so 0 0 0 0
e 00 00 8o
Q eo
®
°
6 000 0 oe 0 0 o 00 000.
SIGN MOUNTING LOCATION (TYP)
FIELD VERIFY EXACT LOCATIONS TYP
e °o
00®
°
A2.1
ALTERNATE SIGN MOUNTING
LOCATION (TYP) FIELD
VERIFY EXACT LOCATIONS
23' - 5" 1' - 2 3/4" 5'- 9 15/16"
THE LEVEL OF ILLUMINATION PROVIDED BY THE LED 6p°
LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED
BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. 106.22 S.F.
'
z
4 R
x
a.
rs
�a
i r
� R
{ 3k
k
u
.............
...... _. ........
11 1/2" 6 9/16" 7 9/16" 4 1/4" 6 9/16" 4 7/16" 37.89 S.F.
4'-6" WALMART SIGN AND MOUNTING DIAGRAM
1 1/4"
w
ww >; ('6
a)
W
9 L lzww (T WZ (D
O zwU. Ozoo
Wo�W��Zz�nF
DOCUMENT DATE:
o
w g aw5UO
PROTO TYPE: 143 Non Proto SC
z�~QgL-w cl w
08/26/16
aW��=a>
WI
Z
O
w_ ¢ Fc
a� wpmyKC90WE0=❑
3m>zzQa z_zW=zoz
4~
zLL WK�0F-�Qz F��ap
_I
¢�QU a'.W (n 2' OUa UzN
p V w w m w- a 5 m O w p
CL
�
to zFw-~O��OW Ii D F ---w
=zx0¢nmw wpww�x
�oVUomwpwc2xx¢=
ISSUE BLOCK
1 PR 1 12/09/16
CHECKED BY:z
_� SLB
DRAWN BY:
_
LSB
DOCUMENT DATE:
11/2/16
PROTO TYPE: 143 Non Proto SC
PROTO CYCLE:
08/26/16
T 0� `
j
e; f
ic. No. 016472
ZWt
DEC 12 2016
EXTERIOR
DETAILS AND
SIGNAGE
SHEET:
A2.1