Loading...
HomeMy WebLinkAboutARB201600143 Certificate of Appropriateness 2016-12-21COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 December 21, 2016 Brittany Lewis HFA 1705 S. Walton Blvd., Suite 3 Bentonville, AR 72712 RE: ARB -2016-143: Walmart Signs (TMP 04500-00-00-068D5) Dear Ms. Lewis, We have reviewed your request for the above -noted signs and have approved the design as illustrated in the attached drawings. You may consider this letter your Certificate of Appropriateness. This approval is predicated on the fact that the design and materials, as proposed and illustrated, will be used. The acceptance of approval implies that the applicant has agreed to execute the design as indicated on the submittal items presented. Any changes in the approved design will require a new application and additional review. PLEASE NOTE: A CHECKED BOX MEANS THESE CONDITIONS APPLY TO YOUR SIGN APPROVAL ® The level of illumination produced by the LED lights shall not exceed the level of illumination produced by a single stroke of 30 milliamp neon. ® This ARB approval is only one approval required prior to installing a sign. An approved sign permit is also required. Please do not proceed with the construction or installation of your sign until you have received your signed permit. If you have questions about the status of a sign permit application, please contact the permit intake staff at 296-5832. If you have any questions concerning this action, please feel free to contact me. Sincerely, Amanda Burbage Senior Planner 434-296-5832 x3023 aburbage@albemarle.org cc: Walmart Real Estate Business Trust, 2001 SE 101 St., Bentonville, AR 72716 CAP PAINT TAGS SHOWN FOR REFERENCE. GC IS ONLY TO TOUCH-UP PAINT AT AREAS AFFECTED BY INSTALLATION OF NEW SIGNAGE. DO NOT PAINT INTREGALLY COLORED BLOCK, QUICK BRICK, OR CONCRETE WALL CAP. CAP P92 PAINT TAGS SHOWN FOR REFERENCE. GC IS ONLY TO TOUCH-UP PAINT AT AREAS AFFECTED BY INSTALLATION OF NEW SIGNAGE. DO NOT PAINT INTREGALLY COLORED BLOCK, QUICK BRICK, OR CONCRETE WALL CAP. DOOR RIGHT VESTIBULE ELEVATION LEFT VESTIBULE ELEVATION 6 1" = 20'-0" 5 1" = 20'-0" I I I I I 1 CAP CAP CAP P92 P92 P92 P89 DOOR LEFT ELEVATION 4 1„ = 20'-0" PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK, TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP. AFFECTED BY INSTALLATION OF NEW SIGNAGE. 3 I CAP P92 P92 SHEET NOTES -REVISED NOTE #1 -REVISED NOTE #5 -REVISED NOTE #7 -ADDED NOTE #8 AND RENUMBERED #9420 DEMOLITION NOTES -REMOVED NOTE #2 AND RENUMBERED #346 -REVISED NOTE #2 DOOR DOOR PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK, REAR ELEVATION 3 TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP. AFFECTED BY INSTALLATION 1" = 20'-0 OF NEW SIGNAGE. I I I I CAP I I I 1 � I DOORS I I I I I I I I I I DOOR DOORS PAINT TAGS SHOWN FOR DO NOT PAINT INTREGALLY GARDEN CENTER METAL REFERENCE. GC IS ONLY TO COLORED BLOCK, QUICK BRICK, CANOPY AND FENCE NOT RIGHT ELEVATION TOUCH-UP PAINT AT AREAS OR CONCRETE WALL CAP. SHOWN FOR CLARITY (:2 AFFECTED BY INSTALLATION OF 1" = 20'-0" NEW SIGNAGE. 1 3 L 53'-2" t Q Q F— EXISTING I I , FRONT ELEVATION 1 1 = 20'-0" IVCVV JIVI17 VCIV I CFNL;L✓ HORIZONTALLY OVER DOORS, REF 4-A2.1 7 75'-n" SOFFIT — NEW SIGN CENTERED HORIZONTALLY OVER DOORS, REF 3-A2.1 DOOR DOOR CAP HARRISON FRENCH & ASSOCIATES, LTD 1705 S. Walton Blvd., Suite 3 Bentonville, Arkansas 72712 t479.273.7780 f 888.520.9685 www.hfa-ae.com LUD SLB U) o i 'zwoi aZL"Zr w W p �rwF=wURZzrnr g=2 www E3. z PROTO TYPE: 143 Non Proto SC uw.UOp2wU O w LL W. ow iii>�zz¢�W. ow Z O_ �wui�¢oQ° �wur.wM< ¢r.-lw !g 70wr 02p 3m�a�ozzW=zOz ~ ZIU-iw c. No. 016472 ^0o��z=��zo Udo`. wma4ouria�znwi D pcoi�9wOmwNaWWQOR3 y¢¢ZFHpH.�owaDl_w 0owQ�ww=U o0(1a<- J W 0 O w 00 W J4 U co w W �0 U O 0_ 0 � oc �Uo& wz F-- W O 0 O � Gij O N ry o Q w W = m UZ 0 ---- ISSUE BLOCK 1 1PR 1 1 12/09/16 CHECKED BY: SLB DRAWN BY: LSB DOCUMENT DATE: 11/2/16 PROTO TYPE: 143 Non Proto SC PROTO CYCLE: 08/26/16 DEC 12 2016 EXTERIOR ELEVATIONS SHEET: A2 •,.1 r-: `} EByy LTJ BRE -CH to 5: c. No. 016472 DEC 12 2016 EXTERIOR ELEVATIONS SHEET: A2 REFER TO SIGNAGE GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. DRILL HOLE AND FEED WHIP THROUGH WALL FULL BED OF MULTI-COMPONENT SEALANT AT PERIMETER OF CONDUIT 1/2" FLEX CONDUIT 20' LONG SUPPLIED IN SIGN CAN- CONTINUOUS. THROUGH ENTIRE WALL — PVC SPACER TO PREVENT COMPRESSION OF METAL PANEL, 3/4" OUTER DIAMETER AND 5/8" INSIDE DIAMETER TYP ABANDON EXISTING HOLES IN SIGN CAN AND DRILL NEW HOLES 2" FROM EXISTING ATTACHMENTS. HOLE SHOULD BE 3/4" DIAMETER FULL BED OF MULTI-COMPONENT SEALANT AT PERIMETER OF SPACER 3"NEOPRENE/SS BONDED WASHER AND NUT IN BED OF CONTINUOUS MULTI-COMPONENT SEALANT REF BLDG EL BO SIGNAGE SIGN CAN WITH .080 ALUMINUM BACKING 1/2" ALL -THREAD CUT TO WITHIN 1/4" OF NUT AND GRIND END SMOOTH WALMART SIGN Viia. = 1'-0" ATTAC EXISTING ROOFING SYSTEM TO JUNCTION BOX, REF ELECTRICAL EXISTING METAL ANGLE, REF STRUC. IF ANGLE SPACING IS GREATER THAN 4'4" OC, PROVIDE 2X TIE BETWEEN INSIDE AND OUTSIDE BLOCKING EXISTING METAL STUDS, REF STRUC EXISTING METAL PANEL NOTE: LOCATE ALL -THREADS PER SIGN ATTACHMENT TEMPLATE. BLOCKING ONLY REQUIRED AT ATTACHMENT POINTS. GC TO COORDINATE WITH SIGN SHOP/INSTALLER FOR LOCATIONS SECTION 2A IN PLAN -NTS HMENT AT METAL WALL PANEL REFER TO SIGNAGE GENERAL NOTES FOR ADDITIONAL REQUIREMENTS MOUNTING HOLE PATTERNS FOR NON - ILLUMINATED SIGN INSTALLATION PLASTIC MOUNT FOR ALL -THREAD STUD TYP INSTALL 1/8" DIAALL- THREAD STUDS INTO PLASTIC MOUNTS m w 3/8" DIA HOLE FILLED WITH ADHESIVE SEALANT PLASTIC NON - ILLUMINATED CHANNEL LETTER "ADHESIVE SEALANT" IS TO BE PRODUCT LN -950 BY LIQUID NAILS OR SIMILAR POLYURETHANE CONSTRUCTION ADHESIVE MEETING ASTM D3498 AND C557 STANDARDS, EXTERIOR APPLICATION, WEATHER RESISTANT, LOW VOC, WITH A MINIMUM SHEAR STRENGTH OF 250 PSI HMENT AT EIFS AND REPLACE EXISTING EIFS AS REQUIRED FOR NEW 5/8" PLYWOOD SHEATHING. RESURFACE EXISTING EIFS TO REMAIN, REF SPECS PRIOR TO PERFORMING THIS WORK, VERIFY EXISTING SUBSTRATE MATERIAL. IF EXISTING SUBSTRATE IS CMU OR PLYWOOD (5/8" OR THICKER), SUBSTRATE REPLACEMENT IS NOT REQ'D REPLACE EXISTING SHEATHING AT SIGN WITH 5/8" EXTERIOR PLYWOOD SHEATHING. INSTALL NEW EIFS AS REQUIRED. MATCH ADJACENT TEXTURE AND FINISH EXISTING FRAMING SIGN ATTAC 1 1/2" = 1'-0" EXISTING METAL PANEL TREATED 2x4 BLOCKS EACH SIDE OF ANGLE ATTACH WITH (2) PAFS SPLICE BLOCKING AS REQD AT ANGLE LEG (2) 3" WOOD SCREW AT EACH 2x4 BLOCK EXISTING METAL ANGLE, REF STRUC ATTACH NEW BLOCKING WITH (2) 1-1/2' WOOD SCREWS EACH END (PRE -DRILL HOLES IN ANGLE) METAL STUD WALL FULL BED OF MULTI- COMPONENT SEALANT AT AT QUIK BRICK WALL PERIMETER OF CONDUIT X t...../............._.......... .............. BY SIGN INSTALLER 1 112" = 1'-0" Y FLEX CONDUIT SUPPLIED WITH LETTERS CONTINUOUS THROUGH AT QUIK BRICK WALL o X 10 ENTIRE PARAPET BY SIGN 1 112" = 1'-0" z�~QgL-w cl w -CUSTOM MANUAL MATCH 1 INSTALLER 128 NOTES FOR ADDITIONAL 1 B1 BLACK 6 4 1 1 REQUIREMENTS. 1 Y3 DEEP GOLD - 48 1 r/ G2 NEW GREEN - 18 - - ONE GALLON #B54T00104 MOUNTING HOLE PATTERNS FOR UI TRADECP #796999993 INSTALL LETTER BACK INSTALLATION PRIOR TO INSTALLATION PLASTIC MOUNT FOR BY SIGN INSTALLER INSTALL 1/8" DIA ALL - THREAD STUDS INTO _..................,... INDIVIDUAL PLASTIC PRIOR TO SIGN ILLUMINATED INSTALLATION, TYP 3/8" DIA HOLE FILLED WITH CHANNEL LETTERS BY -_1 ..-............. __....._..._.._.._.._...'_:.::: SIGN SUPPLIER ALL -THREAD STUD WITH ._.....__......_....__. ------ _........ _... m.._.... INSTALL LETTER FACES TO WALL ATTACHMENT, w W/ SET SCREWS, TYP TYP BY SIGN INSTALLER PLASTIC NOW ILLUMINATED CHANNEL LETTER ,ADHESIVE SEALANT" IS TO BE PRODUCT LN -950 BY LIQUID NAILS OR SIMILAR POLYURETHANE CONSTRUCTION ADHESIVE, MEETING ASTM D3498 AND C557 STANDARDS, EXTERIOR APPLICATION, ' WEATHER RESISTANT, LOW VOC, WITH A MINIMUM SHEAR STRENGTH OF 250 PSI HMENT AT QUIK-BRIK WALL SEALANT ALL AROUND BY BUILDING GENERAL CONTRACTOR CONTINUOUS UNISTRUT PROVIDED BY GENERAL CONTRACTOR. ATTACH AT 48" OC WITH 6x6 STEEL PLATE WITH (4) 1/2" MASONRY EXPANSION ANCHORS. SET PLATE IN FULL BED OF SEALANT. NOTE, UNISTRUT MAY BE ABOVE OR BELOW WIRE PENETRATION 4" X 4" JUNCTION BOX. ATTACH TO UNISTRUT BY BUILDING GENERAL CONTRACTOR LOCATE CONDUIT PENETRATION 4'-0" MAX FROM UNISTRUT. PROVIDE ONLY ONE ROOF PENETRATION FOR ALL WHIPS. LOCATE IMPACT ANCHORS AND WIRING/CONDUIT PENETRATIONS PER SIGN ATTACHMENT TEMPLATE PROVIDED BY WALMART EXISTING QUIK-BRIK SIGN ATTAC NOTE TO SIGN INSTALLER: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED. SIGN MOUNTING_ LOCATION (TYP) FIELD ELECTRICAL PENETRATIONS (TYP) FIELD VERIFY EXACT LOCATIONS VERIFY EXACT LOCATIONS a NOTE:Q u p ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR k` "" MINIMUM OF 8" ABOVE DECK 15'- 4" THE LEVEL OF ILLUMINATION 3'- 10 1/2" 10'- 7 1/2" PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE _ WHITE PLASTIC LETTERS ILLUMINATION PRODUCED r — BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. lc:k�ull L—s -- — J 66.76 SF PLASTIC CHARACTERS INTERNALLY MATCH SW #6904 10 ILLUMINATED 'GUSTO GOLD' 1 TYP 2'-6 PICKUP SIGNAGE 9 1 /4" = 1'-0" 25'- 5 3/8" 00 = ° ii Oiery o'u.�.. e Pho >.� lu"i a _ i� ......... ..... ....._... _.._ ...._._ ... _ . _ __ _. _ 70.30 S.F. 5 TYP A2.1 24" GROCERY & PHARMACY SIGNAGE 17'-5" G) p '<V N o c o 0 0 0 0, oc.:: - °- „o . o 0 0 0 0 5 46.44 SQ.FT. TYP A2.1 24" HOME & LIVING SIGNAGE 1/4 19'- 1 3/8" w -u,' n F x. ,i 41.02 sq.ft 7 TYP A2.1 24" LAWN &GARDEN SIGNAGE DO NOT PAINT EXISTING Mf,Q,_,v4u\ LSIGN E SIGN DONE BY ONTRACTOR WALMART PYLON 6 3/16" = V-0" EXISTING CABINET TO REMAIN, PAINT TRIM AND CABINET "DURANODIC BRONZE" -REFERENCE TABLE EXISTING BRAND FACE TO REMAIN SHERWIN-WILLIAMS DURANODIC AT QUIK BRICK WALL PICKUP SIGNAGE ATTACHMEN 10 o w g aw5UO 1 112" = 1'-0" z�~QgL-w cl w -CUSTOM MANUAL MATCH REFER TO SIGNAGE GENERAL _ BAC COLORANT: OZ 32 64 128 NOTES FOR ADDITIONAL 1 B1 BLACK 6 4 1 1 REQUIREMENTS. 1 Y3 DEEP GOLD - 48 1 1 G2 NEW GREEN - 18 - - ONE GALLON #B54T00104 MOUNTING HOLE PATTERNS FOR UI TRADECP #796999993 NON -ILLUMINATED SIGN INSTALLATION PLASTIC MOUNT FOR ALL -THREAD STUD, TYP INSTALL 1/8" DIA ALL - THREAD STUDS INTO PLASTIC MOUNTS PRIOR TO SIGN INSTALLATION, TYP 3/8" DIA HOLE FILLED WITH ADHESIVE SEALANT. COAT ALL -THREAD STUD WITH ADHESIVE SEALANT PRIOR c) TO WALL ATTACHMENT, w TYP PLASTIC NOW ILLUMINATED CHANNEL LETTER ,ADHESIVE SEALANT" IS TO BE PRODUCT LN -950 BY LIQUID NAILS OR SIMILAR POLYURETHANE CONSTRUCTION ADHESIVE, MEETING ASTM D3498 AND C557 STANDARDS, EXTERIOR APPLICATION, ' WEATHER RESISTANT, LOW VOC, WITH A MINIMUM SHEAR STRENGTH OF 250 PSI HMENT AT QUIK-BRIK WALL SEALANT ALL AROUND BY BUILDING GENERAL CONTRACTOR CONTINUOUS UNISTRUT PROVIDED BY GENERAL CONTRACTOR. ATTACH AT 48" OC WITH 6x6 STEEL PLATE WITH (4) 1/2" MASONRY EXPANSION ANCHORS. SET PLATE IN FULL BED OF SEALANT. NOTE, UNISTRUT MAY BE ABOVE OR BELOW WIRE PENETRATION 4" X 4" JUNCTION BOX. ATTACH TO UNISTRUT BY BUILDING GENERAL CONTRACTOR LOCATE CONDUIT PENETRATION 4'-0" MAX FROM UNISTRUT. PROVIDE ONLY ONE ROOF PENETRATION FOR ALL WHIPS. LOCATE IMPACT ANCHORS AND WIRING/CONDUIT PENETRATIONS PER SIGN ATTACHMENT TEMPLATE PROVIDED BY WALMART EXISTING QUIK-BRIK SIGN ATTAC NOTE TO SIGN INSTALLER: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED. SIGN MOUNTING_ LOCATION (TYP) FIELD ELECTRICAL PENETRATIONS (TYP) FIELD VERIFY EXACT LOCATIONS VERIFY EXACT LOCATIONS a NOTE:Q u p ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR k` "" MINIMUM OF 8" ABOVE DECK 15'- 4" THE LEVEL OF ILLUMINATION 3'- 10 1/2" 10'- 7 1/2" PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE _ WHITE PLASTIC LETTERS ILLUMINATION PRODUCED r — BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. lc:k�ull L—s -- — J 66.76 SF PLASTIC CHARACTERS INTERNALLY MATCH SW #6904 10 ILLUMINATED 'GUSTO GOLD' 1 TYP 2'-6 PICKUP SIGNAGE 9 1 /4" = 1'-0" 25'- 5 3/8" 00 = ° ii Oiery o'u.�.. e Pho >.� lu"i a _ i� ......... ..... ....._... _.._ ...._._ ... _ . _ __ _. _ 70.30 S.F. 5 TYP A2.1 24" GROCERY & PHARMACY SIGNAGE 17'-5" G) p '<V N o c o 0 0 0 0, oc.:: - °- „o . o 0 0 0 0 5 46.44 SQ.FT. TYP A2.1 24" HOME & LIVING SIGNAGE 1/4 19'- 1 3/8" w -u,' n F x. ,i 41.02 sq.ft 7 TYP A2.1 24" LAWN &GARDEN SIGNAGE DO NOT PAINT EXISTING Mf,Q,_,v4u\ LSIGN E SIGN DONE BY ONTRACTOR WALMART PYLON 6 3/16" = V-0" EXISTING CABINET TO REMAIN, PAINT TRIM AND CABINET "DURANODIC BRONZE" -REFERENCE TABLE EXISTING BRAND FACE TO REMAIN SHERWIN-WILLIAMS DURANODIC ww >; ('6 BRONZE/ ORDER NUMBER 7248- 9 L lzww (T WZ (D O zwU. Ozoo Wo�W��Zz�nF 0044642 o w g aw5UO - BRONZE MATCH z�~QgL-w cl w -CUSTOM MANUAL MATCH aW��=a> WI BAC COLORANT: OZ 32 64 128 W1 WHITE 43 1 B1 BLACK 6 4 1 1 R2 MAROON - 19 - 1 Y3 DEEP GOLD - 48 1 1 G2 NEW GREEN - 18 - - ONE GALLON #B54T00104 UI TRADECP #796999993 NOTE TO SIGN INSTALLER: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED. ELECTRICAL PENETRATION (TYP) FIELD VERIFY EXACT LOCATIONS ° ® so 0 0 0 0 e 00 00 8o Q eo ® ° 6 000 0 oe 0 0 o 00 000. SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONS TYP e °o 00® ° A2.1 ALTERNATE SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONS 23' - 5" 1' - 2 3/4" 5'- 9 15/16" THE LEVEL OF ILLUMINATION PROVIDED BY THE LED 6p° LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. 106.22 S.F. ' z 4 R x a. rs �a i r � R { 3k k u ............. ...... _. ........ 11 1/2" 6 9/16" 7 9/16" 4 1/4" 6 9/16" 4 7/16" 37.89 S.F. 4'-6" WALMART SIGN AND MOUNTING DIAGRAM 1 1/4" w ww >; ('6 a) W 9 L lzww (T WZ (D O zwU. Ozoo Wo�W��Zz�nF DOCUMENT DATE: o w g aw5UO PROTO TYPE: 143 Non Proto SC z�~QgL-w cl w 08/26/16 aW��=a> WI Z O w_ ¢ Fc a� wpmyKC90WE0=❑ 3m>zzQa z_zW=zoz 4~ zLL WK�0F-�Qz F��ap _I ¢�QU a'.W (n 2' OUa UzN p V w w m w- a 5 m O w p CL � to zFw-~O��OW Ii D F ---w =zx0¢nmw wpww�x �oVUomwpwc2xx¢= ISSUE BLOCK 1 PR 1 12/09/16 CHECKED BY:z _� SLB DRAWN BY: ­_ LSB DOCUMENT DATE: 11/2/16 PROTO TYPE: 143 Non Proto SC PROTO CYCLE: 08/26/16 T 0� ` j e; f ic. No. 016472 ZWt DEC 12 2016 EXTERIOR DETAILS AND SIGNAGE SHEET: A2.1