HomeMy WebLinkAboutSDP201600067 Review Comments Initial Site Plan 2016-12-28Charles A. Kilpatrick, P.E. Commissioner COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper Virginia 22701 December 15, 2016 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Christopher Perez Re: The Shops at Westfield- Initial site plan SDP -2016-00067 Review #1 Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Bohler Engineering, dated November 11, 2016 and offers the following comments: Land Use I . The proposed entrance on route 29 doesn't meet current spacing standards. Please see Road Design Manual appendix F -Access Management design standards, page, F23. The applicant may apply for an exception to the spacing with an AM -E submission. If so desired, we recommend a meeting to discuss the process. 2. The entrance onto Westfield Road (SR 1452) does not meet corner clearance standards as shown in Road Design Manual appendix F. Pg. 116. As proposed this entrance will require an approved access management exception (AM -E). 3. Please see Road Design Manual appendix F -Access Management design standards for entrances and Intersections, figure 4-10 commercial entrance design. Single two-way entrance with right turn and taper. Current design is proposing a 20' radii on both entrances, the minimum should be 25'. The proposed entrance on route 29 is 24' in width, should be a minimum of 30'. Please refer to F-109 to provide the appropriate design vehicle and turning radius by land use. 4. Please show mill and overlay on plans in accordance with WP -2 and add the detail to the plans. 5. The mill and overlay will require work to centerline, so flagging operation will be necessary. 6. Please provide detailed trip generation data (ITE) and provide turn lane warrant analyses for both left and right turn lanes. 7. Proposed drainage structures tying into existing drainage structures. Please provide drainage calculation data sheet and show that the existing system will be adequate in the post -development condition. December 15, 2016 Christopher Perez Page 2 Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B (1) and F, as well as any other applicable standards, regulations, or other requirements. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process Sincerely, 4x - P+V6t--'1 Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING