Loading...
HomeMy WebLinkAboutARB201600071 Plan - Approved 2016-12-30ELECTRICAL SYMBOL LEGEND NOTES: I. SEE DETAIL FOR STANDARD MOUNTING HEIGHTS OF ALL DEVICES, UNLESS OTHERWISE NOTED. 2. ALL DEVICES (SWITCHES AND RECEPTACLES) SHALL BE GREY WITH 302 STAINLESS STEEL COVER PLATES, UNLESS OTHERWISE NOTED. 3. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. ESD-1642-EO1.dwg, Plotted By. ryan _ Dec 22. 2016 - 6:54am GENERAL ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL LOCAL AND STATE CODES. 2. ALL MATERIAL, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE NEW AND SHALL CONFORM TO THE STANDARDS OF THE UNDERWRITER'S LABORATORIES, INC., AND THE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 3. ALL ELECTRICAL PERMITS AND INSPECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE ELECTRICAL CONTRACTOR. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE ONLY THE GENERAL ARRANGEMENT. SEE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 4. ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR EFFECTIVE THE DAY THE PROJECT IS ACCEPTED BY THE OWNER. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL ELECTRICAL POWER CONNECTIONS TO HVAC, PLUMBING AND OTHER EQUIPMENT AS REQUIRED. 6. A COMPLETE GROUNDING SYSTEM SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NEC, AND AS SHOWN ON THE DRAWINGS. 7. ALL CUTTING AND PATCHING OF WALLS AND FLOORS FOR ELECTRICAL EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 8. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 VOLTS. MINIMUM SIZE SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON THE DRAWINGS. ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED. ALL CONDUCTORS #10 AND SMALLER SHALL BE SOLID, UNLESS OTHERWISE NOTED. BRANCH CIRCUIT CONDUCTORS SHALL BE TYPE THHN OR THWN AS REQ'D. 9. ALL WIRING SHALL BE INSTALLED IN GALVANIZED RIGID CONDUIT, INTERMEDIATE METAL CONDUIT, OR EMT UNLESS OTHERWISE NOTED. EMT SHALL NOT BE USED IN OR UNDER CONCRETE SLABS, OR IN MASONRY WALLS. USE SCHEDULE 40 PVC OUTDOORS WHERE NOT SUBJECT TO PHYSICAL DAMAGE OR BELOW FLOOR SLAB. MINIMUM CONDUIT SIZE TO BE 1/2". TYPE MC AND AC CABLE MAY BE USED WHERE PERMISSIBLE BY NEC. 10. PROVIDE A PULLWIRE IN ALL EMPTY CONDUITS. 11. PROVIDE A TYPED DIRECTORY IN ALL PANELBOARDS CLEARLY DESCRIBING THE LOCATION OF AND TYPE OF LOAD BEING SERVED FOR ALL CIRCUITS. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOARDS AND DISCONNECT SWITCHES, WHITE LETTERS ON BLACK BACKGROUND. 12. FUSES 0 - 600 AMPS SHALL BE UL CLASS "RK -1" LOW PEAK DUAL ELEMENT TIME DELAY WITH 200,000 AMPERE INTERRUPTING RATING AS MANUFACTURED BY BUSSMANN, UNLESS NOTED OTHERWISE. 13. ALL TERMINALS/LUGS SHALL BE 60/75° RATED. ALL TERMINALS, SPLICING CONNECTORS, LUGS, ETC SHALL BE IDENTIFIED FOR USE WITH THE MATERIAL (CU/AL) OF THE CONDUCTOR AND SHALL BE PROPERLY INSTALLED. 14. VERIFY ALL REQUIREMENTS AND COORDINATE EXACT LOCATION OF INCOMING ELECTRICAL SERVICE WITH LOCAL POWER COMPANY PRIOR TO PROJECT START-UP. NOTIFY ENGINEER OF ANY CHANGES AS MAY BE REQUIRED. 15. E.C. TO VERIFY DEVICE PLATE COLOR AND MATERIAL WITH ARCHITECT PRIOR TO PURCHASE. 16. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELECTRICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). 17. PENETRATIONS OF REQUIRED SMOKE PARTITIONS SHALL BE SEALED USING METHODS APPROVED UNDER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THIS SMOKE STOPPING IS ACCOMPLISHED. 15. WHERE PENETRATIONS ARE MADE THROUGH A REQUIRED FIRE-RE515TIVE WALL, FLOOR, OR PARTITION FOR THE PURPOSE OF RUNNING RACEWAY CARRYING ELECTRICAL, TELEPHONE, TELEVISION, OR LOCAL COMMUNICATION AND/OR SIGNALING CIRCUITS, THE OPENING AROUND THE RACEWAY SHALL BE FIRE STOPPED PER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THI5 FIRE STOPPING IS ACCOMPLISHED. USE APPROVED U.L. OR EQUIVALENT ASSEMBLIES. 19. IN REQUIRED FIRE RATED WALLS AND PARTITIONS, OPENINGS FOR INSTALLATION OF BOXES THAT ARE GREATER THAN 16 SQUARE INCHES SHALL BE PROTECTED AS REQUIRED BY U.L. COORDINATE CLOSELY WITH THE GENERAL CONTRACTOR TO INSURE THAT THE INTEGRITY OF THE U.L. RATING IS MAINTAINED. 20. WHERE A HOME RUN IS SHOWN THE CIRCUIT SHALL BE INSTALLED IN A DEDICATED CONDUIT, DO NOT COMBINE WITH OTHER CIRCUITS. WHERE A CIRCUIT HOMERUN IS NOT SHOWN, THE CONTRACTOR SHALL COMBINE CIRCUITS AS FOLLOWS: A MAXIMUM OF THREE 20A BRANCH CIRCUITS MAY BE COMBINED IN A COMMON HOMERUN SNARING A COMMON NEUTRAL OR WITH SEPARATE NEUTRALS FOR A MAXIMUM TOTAL OF SIX CURRENT CARRYING CONDUCTORS. ALL BRANCH CIRCUITS LARGER THAN 20A SHALL BE SEPARATELY HOMERUN TO THE PANEL. 21. COORDINATE WITH THE CABLE TV AND TELEPHONE UTILITIES AS REQUIRED FOR SERVICE ENTRANCE REQUIREMENTS. INSTALLATION MUST COMPLY WITH THEIR RESPECTIVE REGULATIONS AND REQUIREMENTS. 22. RECEPTACLES SHALL BE SPECIFICATION GRADE EQUAL TO HUBBELL 5300 SERIES, GROUND FAULT RECEPTACLES SHALL BE HUBBELL GF -5362. LIGHTING SWITCHES SHALL BE SPECIFICATION GRADE EQUAL TO HUBBELL 1200 SERIES. 23. ALL EXTERIOR FIXTURES AND DEVICES SHALL BE RATED FOR OPERATION AT 0° F AND SHALL BE DAMP OR WET LABELED AS REQUIRED. 24. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL ELECTRICAL EQUIPMENT, DEVICES, ETC. IN ACCORDANCE WITH LOCAL SEISMIC CODE REQUIREMENTS. PROVIDE SEISMIC RESTRAINTS, ACCESSORIES AND INSTALLATION DETAIL AS REQUIRED. 25. VERIFY THAT ALL CONDUIT PENETRATIONS OF THE WALK-IN REFRIGERATOR AND FREEZER ARE SEALED PER 300.7(A). 26. ELECTRICAL CONTRACTOR TO COORDINATE THE EXACT MCA/MOCP REQUIREMENTS OF ALL EQUPMENT WITH ALL OTHER TRADES PRIOR TO PRICING, ORDERING, OR INSTALLING ANY ELECTRICAL GEAR. THIS SHALL INCLUDE BUT NOT LIMITED TO ALL HVAC, PLUMBING, KITCHEN, OWNER PROVIDED EQUIPMENT, ETC. ELECTRICAL ABBREVIATIONS CIRCUIT CONDUCTORS CONCEALED IN FLOOR, WALL OR CEILING. DIMENSION INDICATES HEIGHT ABOVE FINISHED ARROWHEAD INDICATES 140MERUN TO PANEL NOTED. FLOOR AT WHICH CENTER OF DEVICE IS TO BE INDICATES HOT LEG OF CIRCUIT TO BE CARRIED OVER TO NEXT DEVICE. SEE PLANS MOUNTED. FOR CONTROL SCHEME. Q JUNCTION BOX. $ SINGLE POLE SWITCH, 20A, 120/277 VOLT, 48" A.F.F. TO CENTER. ELECTRICAL CONTRACTOR. "3" INDICATES 3 -WAY SWITCH. FUSE PER EQUIPMENT NAMEPLATE REQUIREMENTS. "4" INDICATES 4 -WAY SWITCH. GENERAL CONTRACTOR. "D" INDICATES DIMMER SWITCH OF TYPE TO SUIT LOAD. MECHANICAL CONTRACTOR. "K" INDICATES KEY OPERATED SWITCH. PLUMBING CONTRACTOR. "M" INDICATES 120V, 20A MOTOR RATED TOGGLE SWITCH. INDICATES DEVICE TO HAVE WEATHERPROOF INDICATES FLUORESCENT FIXTURES DUAL SWITCHED, INBOARD/OUTBOARD SWITCHED COVER. SEPARATELY. K9 SINGLE RECESSED CLOCK RECEPTACLE FOR FLY LIGHT, 20 AMP, 120 VOLT. FIRE ALARM CONTROL PANEL. DUPLEX RECEPTACLE, 15 AMP, 120 VOLT, 18" A.F.F. TO CENTER. 120 "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE ELECTRONIC "WP" INDICATES WEATHERPROOF RECESSED ' EWC" INDICATES MOUNT INSIDE ENCLOSURE OF ELECTRIC WATER COOLER. WITH 0.125" THICK ACRYLIC LENS. WHITE BAKED ENAMEL FINISH. PROVIDE gOMIN. "USB" INDICATES DUPLEX RECEPTACLE WITH (2) USB PORTS. � QUADRUPLEX RECEPTACLE, AS ABOVE, 18" A.F.F. ® SPECIAL EQUIPMENT CONNECTION. COORDINATE EXACT CONNECTION REQUIREMENTS c WITH KITCHEN INSTALLER. © COMMUNICATIONS SYSTEM J -BOX. CONDUIT SIZE AS INDICATED, INSIDE WALL, TO Z ABOVE ACCESSIBLE CEILING. 1400 LUMEN BATTERY PACK FOR NL FIXTURES. DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE LSI-QLS BACK5PLA5H, AS APPROPRIATE, OR AT HEIGHT INDICATED. 3 DUPLEX RECEPTACLE, AS ABOVE, MOUNTED 6" ABOVE COUNTER TOP OR 4" ABOVE 120 BACK5PLA5H, AS APPROPRIATE, OR AT HEIGHT INDICATED, WITH GFI PROTECTION. ELECTRONIC 20BV RECEPTACLE, SEE PLANS FOR NEMA CONFIGURATION. RECESSED TELEPHONE OUTLET, 18" A.F.F. TO CENTER, UNLESS OTHERWISE NOTED. PROVIDE SAME AS FIXTURE TYPE 'A' EXCEPT PROVIDED SINGLE GANG RECESSED J -BOX WITH 3/4" CONDUIT TO ACCESSIBLE CEILING. PROVIDE M CAT 6, 4 -PAIR CABLE FROM EACH TELEPHONE J -BOX BACK TO TELEPHONE BOARD DEMARCATION LOCATION. PROVIDE TELEPHONE JACK AND FACEPLATE AT OFFICE AND DRIVE THRU TELEPHONE LOCATIONS. O DATA OUTLET, 18" A.F.F. TO CENTER, UNLESS OTHERWISE NOTED. PROVIDE d SINGLE GANG RECESSED J -BOX WITH 3/4" CONDUIT TO ACCESSIBLE CEILING. PROVIDE WITH FLANGE MOUNTING OPTION. CAT 6, 4 -PAIR, CABLE FROM EACH DATA J -BOX BACK TO A CENTRAL POINT IN r-- OFFICE, COORDINATE EXACT TERMINATION POINT WITH OWNER. p, HEAVY DUTY FUSIBLE/NON-FUSIBLE DISCONNECT SWITCH, NUMBERS INDICATE FRAME 30/3/FPN SIZE, NUMBER OF POLES AND FUSING. PROVIDE NEMA I ENCLOSURE INSIDE. PROVIDE 4 NEMA 3 ENCLOSURE FOR ALL SWITCHES LOCATED OUTSIDE. "FPN" INDICATES FUSE PER EQUIPMENT NAMEPLATE PROVIDE WITH 0.125" DROPPED PRISMATIC "NF" INDICATES NON-FUSED. LSI-QLS I 208Y/120V PANEL, SURFACE OR RECESS MOUNTED, SEE SCHEDULE FOR DETAILS. \0\FAN, PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL 1 CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED. O WATER HEATER, PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR, WIRED BY RECESSED FLUORESCENT DOWNLIGHT. ELECTRICAL CONTRACTOR. PROVIDE DISCONNECTING MEANS AS REQUIRED. I" RECESSED MOUNTED 2x4 FLUORESCENT TROFFER, SEE FIXTURE SCHEDULE FOR DETAILS. 514ADING AND/OR NL INDICATES NIGHT LIGHT. �� SURFACE MOUNTED FLUORESCENT STRIP, SEE FIXTURE SCHEDULE FOR DETAILS. WALL MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE FOR DETAILS. V SURFACE, RECESSED OR GROUND MOUNTED LIGHTING FIXTURE, SEE FIXTURE SCHEDULE • FOR DETAILS. NL INDICATES NIGHT LIGHT FIXTURE B3 ELECTRIC UTILITY METER LOCATION. ® EXIT LIGHT, CEILING AND WALL MOUNTED RESPECTIVELY, SHADING INDICATES FACE. LED PROVIDE RED LETTERS WITH BLACK HOUSING AND EMERGENCY BATTERY PACK RATED - FOR qO MINUTE DURATION. WIRE TO HOT LEG OF LOCAL LIGHTING CIRCUIT. 60 EMERGENCY LIGHT, WALL MOUNTED WITH EMERGENCY BATTERY PACK RATED FOR 18X18 RECESSED LED DOWNLIGHT IN CANOPY. FOR 90 MINUTE DURATION. WIRE TO HOT LEG OF LOCAL LIGHTING CIRCUIT. M4 REMOTE MOUNTED LAMP HEAD, WALL MOUNTED WITH EMERGENCY BATTERY PACK RATED 120 -DFL FOR qO MINUTE DURATION. WIRE TO 140T LEG OF LOCAL LIGHTING CIRCUIT. 7 CABLE TV OUTLET, 18" A.F.F. TO CENTER, UNLESS OTHERWISE NOTED. PROVIDE � EMPTY 3/4"C TO ABOVE ACCESSIBLE CEILING. O SPEAKER LOCATION. L'J 120V DOORBELL PUSHBUTTON AND BELL CHIME. Q DUCT MOUNTED SMOKE DETECTOR, CONNECT TO 120V CIRCUIT INDICATED. DETECTOR SHALL BE SUPPLIEDBY E.C. AND INSTALLED BY M.C., 120V WIRING BY E.C. ® DUCT DETECTOR AUDIO/VISUAL DEVICE WITH REMOTE TEST SWITCH MOUNTED 40AFF. SEE WIRING DIAGRAM ON SHEET E5 FOR DETAILS. ®CLC 120V CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SET FOR 30 (olg40-782/RM SPEC MINUTES. COORDINATE ALL WIRING REQUIREMENTS WITH MANUFACTURER. 25W AN WALL MOUNTED OCCUPANCY SENSOR AT 40AFF SET FOR 15 MINUTES. NOTES: I. SEE DETAIL FOR STANDARD MOUNTING HEIGHTS OF ALL DEVICES, UNLESS OTHERWISE NOTED. 2. ALL DEVICES (SWITCHES AND RECEPTACLES) SHALL BE GREY WITH 302 STAINLESS STEEL COVER PLATES, UNLESS OTHERWISE NOTED. 3. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. ESD-1642-EO1.dwg, Plotted By. ryan _ Dec 22. 2016 - 6:54am GENERAL ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL LOCAL AND STATE CODES. 2. ALL MATERIAL, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE NEW AND SHALL CONFORM TO THE STANDARDS OF THE UNDERWRITER'S LABORATORIES, INC., AND THE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 3. ALL ELECTRICAL PERMITS AND INSPECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE ELECTRICAL CONTRACTOR. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE ONLY THE GENERAL ARRANGEMENT. SEE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 4. ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR EFFECTIVE THE DAY THE PROJECT IS ACCEPTED BY THE OWNER. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL ELECTRICAL POWER CONNECTIONS TO HVAC, PLUMBING AND OTHER EQUIPMENT AS REQUIRED. 6. A COMPLETE GROUNDING SYSTEM SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NEC, AND AS SHOWN ON THE DRAWINGS. 7. ALL CUTTING AND PATCHING OF WALLS AND FLOORS FOR ELECTRICAL EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 8. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 VOLTS. MINIMUM SIZE SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON THE DRAWINGS. ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED. ALL CONDUCTORS #10 AND SMALLER SHALL BE SOLID, UNLESS OTHERWISE NOTED. BRANCH CIRCUIT CONDUCTORS SHALL BE TYPE THHN OR THWN AS REQ'D. 9. ALL WIRING SHALL BE INSTALLED IN GALVANIZED RIGID CONDUIT, INTERMEDIATE METAL CONDUIT, OR EMT UNLESS OTHERWISE NOTED. EMT SHALL NOT BE USED IN OR UNDER CONCRETE SLABS, OR IN MASONRY WALLS. USE SCHEDULE 40 PVC OUTDOORS WHERE NOT SUBJECT TO PHYSICAL DAMAGE OR BELOW FLOOR SLAB. MINIMUM CONDUIT SIZE TO BE 1/2". TYPE MC AND AC CABLE MAY BE USED WHERE PERMISSIBLE BY NEC. 10. PROVIDE A PULLWIRE IN ALL EMPTY CONDUITS. 11. PROVIDE A TYPED DIRECTORY IN ALL PANELBOARDS CLEARLY DESCRIBING THE LOCATION OF AND TYPE OF LOAD BEING SERVED FOR ALL CIRCUITS. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOARDS AND DISCONNECT SWITCHES, WHITE LETTERS ON BLACK BACKGROUND. 12. FUSES 0 - 600 AMPS SHALL BE UL CLASS "RK -1" LOW PEAK DUAL ELEMENT TIME DELAY WITH 200,000 AMPERE INTERRUPTING RATING AS MANUFACTURED BY BUSSMANN, UNLESS NOTED OTHERWISE. 13. ALL TERMINALS/LUGS SHALL BE 60/75° RATED. ALL TERMINALS, SPLICING CONNECTORS, LUGS, ETC SHALL BE IDENTIFIED FOR USE WITH THE MATERIAL (CU/AL) OF THE CONDUCTOR AND SHALL BE PROPERLY INSTALLED. 14. VERIFY ALL REQUIREMENTS AND COORDINATE EXACT LOCATION OF INCOMING ELECTRICAL SERVICE WITH LOCAL POWER COMPANY PRIOR TO PROJECT START-UP. NOTIFY ENGINEER OF ANY CHANGES AS MAY BE REQUIRED. 15. E.C. TO VERIFY DEVICE PLATE COLOR AND MATERIAL WITH ARCHITECT PRIOR TO PURCHASE. 16. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELECTRICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC.). 17. PENETRATIONS OF REQUIRED SMOKE PARTITIONS SHALL BE SEALED USING METHODS APPROVED UNDER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THIS SMOKE STOPPING IS ACCOMPLISHED. 15. WHERE PENETRATIONS ARE MADE THROUGH A REQUIRED FIRE-RE515TIVE WALL, FLOOR, OR PARTITION FOR THE PURPOSE OF RUNNING RACEWAY CARRYING ELECTRICAL, TELEPHONE, TELEVISION, OR LOCAL COMMUNICATION AND/OR SIGNALING CIRCUITS, THE OPENING AROUND THE RACEWAY SHALL BE FIRE STOPPED PER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THI5 FIRE STOPPING IS ACCOMPLISHED. USE APPROVED U.L. OR EQUIVALENT ASSEMBLIES. 19. IN REQUIRED FIRE RATED WALLS AND PARTITIONS, OPENINGS FOR INSTALLATION OF BOXES THAT ARE GREATER THAN 16 SQUARE INCHES SHALL BE PROTECTED AS REQUIRED BY U.L. COORDINATE CLOSELY WITH THE GENERAL CONTRACTOR TO INSURE THAT THE INTEGRITY OF THE U.L. RATING IS MAINTAINED. 20. WHERE A HOME RUN IS SHOWN THE CIRCUIT SHALL BE INSTALLED IN A DEDICATED CONDUIT, DO NOT COMBINE WITH OTHER CIRCUITS. WHERE A CIRCUIT HOMERUN IS NOT SHOWN, THE CONTRACTOR SHALL COMBINE CIRCUITS AS FOLLOWS: A MAXIMUM OF THREE 20A BRANCH CIRCUITS MAY BE COMBINED IN A COMMON HOMERUN SNARING A COMMON NEUTRAL OR WITH SEPARATE NEUTRALS FOR A MAXIMUM TOTAL OF SIX CURRENT CARRYING CONDUCTORS. ALL BRANCH CIRCUITS LARGER THAN 20A SHALL BE SEPARATELY HOMERUN TO THE PANEL. 21. COORDINATE WITH THE CABLE TV AND TELEPHONE UTILITIES AS REQUIRED FOR SERVICE ENTRANCE REQUIREMENTS. INSTALLATION MUST COMPLY WITH THEIR RESPECTIVE REGULATIONS AND REQUIREMENTS. 22. RECEPTACLES SHALL BE SPECIFICATION GRADE EQUAL TO HUBBELL 5300 SERIES, GROUND FAULT RECEPTACLES SHALL BE HUBBELL GF -5362. LIGHTING SWITCHES SHALL BE SPECIFICATION GRADE EQUAL TO HUBBELL 1200 SERIES. 23. ALL EXTERIOR FIXTURES AND DEVICES SHALL BE RATED FOR OPERATION AT 0° F AND SHALL BE DAMP OR WET LABELED AS REQUIRED. 24. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL ELECTRICAL EQUIPMENT, DEVICES, ETC. IN ACCORDANCE WITH LOCAL SEISMIC CODE REQUIREMENTS. PROVIDE SEISMIC RESTRAINTS, ACCESSORIES AND INSTALLATION DETAIL AS REQUIRED. 25. VERIFY THAT ALL CONDUIT PENETRATIONS OF THE WALK-IN REFRIGERATOR AND FREEZER ARE SEALED PER 300.7(A). 26. ELECTRICAL CONTRACTOR TO COORDINATE THE EXACT MCA/MOCP REQUIREMENTS OF ALL EQUPMENT WITH ALL OTHER TRADES PRIOR TO PRICING, ORDERING, OR INSTALLING ANY ELECTRICAL GEAR. THIS SHALL INCLUDE BUT NOT LIMITED TO ALL HVAC, PLUMBING, KITCHEN, OWNER PROVIDED EQUIPMENT, ETC. ELECTRICAL ABBREVIATIONS IS" DIMENSION INDICATES HEIGHT ABOVE FINISHED MARK FLOOR AT WHICH CENTER OF DEVICE IS TO BE CATALOG MOUNTED. AFF ABOVE FINISHED FLOOR. AFG ABOVE FINISHED GRADE. EC ELECTRICAL CONTRACTOR. FPN FUSE PER EQUIPMENT NAMEPLATE REQUIREMENTS. GC GENERAL CONTRACTOR. MC MECHANICAL CONTRACTOR. PC PLUMBING CONTRACTOR. WP INDICATES DEVICE TO HAVE WEATHERPROOF 4 COVER. UON UNLESS OTHERWISE NOTED. FACP FIRE ALARM CONTROL PANEL. THE ARCHITECT/ENGINEER DOES NOT DEFINE THE SCOPE OF INDIVIDUAL TRADES, SUBCONTRACTORS, MATERIAL SUPPLIERS, OR VENDORS. ANY SHEET NUMBERING SYSTEM USED WHICH IDENTIFIES DISCIPLINES IS SOLELY TO SEPARATE ARCHITECT'S AND ENGINEER'S SCOPE; IT DOES NOT DEFINE A SUBCONTRACTOR'S SCOPE OF WORK. NO CONSIDERATION WILL BE GIVEN TO REQUESTS FOR CHANGE ORDERS FOR FAILURE TO IES ROAD REPORT PHOTOMETRIC FILENAME: XSL2-5A-LED-50-SS-CW-DFL.IES ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINANCE 3 2 0 0 I 1.75 2 2.75 3 4 Distance In Units Of Mounting Height Values Based On 10 Foot Mounting Height 1/2 Maximum Candela Trace Shown As Dashed Curve (+) = Maximum Candela Point House Side Street Side 7 Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 6 Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. FIXTURE TYPE 'C' ILLUMINATION LEVELS G I\ Ill t t\ G G R t I\ v 2923 South Tryon Street Suite 280 Charlotte, North Carolina 28203 tel 704.373.0068 fax 704.373.0260 hAPr'I-IAKIICAI PI PrTPICAI PI 1IAARIKir- NOTES: 1. ALL FLUORESCENT LAMPS SHALL BE T8 OCTRON XP5/ECO 4100K AS SPECIFIED. ALL FLUORESCENT BALLASTS SHALL BE AS SPECIFIED. SUBMITTAL SHEETS SHALL BE SUBMITTED WITH FIXTURE SUBMITTALS. FLUORESCENT LAMP AND BALLAST WARRANTY SHALL BE COMPLETED BY CONTRACTOR AND TURNED OVER TO OWNER AT END OF PROJECT. 2. ALL INCANDESCENT LIGHT FIXTURES SHALL HAVE A U.L. LABEL INDICATING THAT THE LAMP WATTAGE SPECIFIED ABOVE 15 THE MAXIMUM ALLOWABLE IN FIXTURE. 3. ALL 3 AND 4 LAMP ELECTRONIC BALLASTS SHALL HAVE INBOARD/OUTBOARD SWITCHING AS INDICATED ON THE DRAWINGS. TANDEM FIXTURES ARE ALLOWED TO FACILITATE INBOARD/ OUTBOARD SWITCHING. 4. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS. 5. ALIGN ALL HORIZONTAL FLUORESCENT DOWN LIGHTS 50 THAT THE COMPACT FLUORESCENT LAMPS ARE ALIGNED IN THE SAME DIRECTION. 6. ALL METAL HALIDE LAMPS SHALL HAVE A CRI OF NOT LESS THAN 70. 7. ALL ELECTRONIC BALLASTS FOR T5(5/8" DIAMETER) LAMPS AND BELOW SHALL HAVE END OF LIFE SHUTDOWN PROTECTION 8. PROVIDE LOW -TEMP (0°F MINIMUM) BALLA5T(5) FOR ALL FIXTURES INSTALLED IN EXTERIOR LOCATIONS OR OTHER AREAS SUBJECT TO COLD WEATHER. q. SUSPEND TWO OPPOSITE CORNERS WITH WIRE TO STRUCTURE. DO NOT ALLOW GRID ALONE TO SUPPORT FIXTURES. 10. ALL EMERGENCY LIGHTS TO BE EQUIPPED WITH A LOCAL MEANS OF TESTING LIGHT FUNCTION WITHOUT DISASSEMBLY OF LIGHTING FIXTURES OR SWITCHING OFF ENTIRE LIGHTING CIRCUITS. 11. SEE CIVIL SHEET Cq FOR 51TE LIGHTING SPECIFICATIONS AND 51TE POLE LOCATIONS. ALL 51TE LIGHTS TO BE PROVIDED, WIRED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. N ■ ■ ■ ■ ■ ■ LIGHTING FIXTURE SCHEDULE O MARK MANUF. CATALOG LAMP DATA VOLTS BALLAST DATA INPUT MOUNTING DESCRIPTION DETAILS N0. TYPE NO TYPE ti NUMBER co WATTS 4 A LSI-QLS G A 3 32 5D 55010 LB841 3 3-Fo32/841/ECO 120 1 ELECTRONIC 69 RECESSED 2X4 ACRYLIC LAY -IN FLUORESCENT WITH 0.125" THICK ACRYLIC LENS. WHITE BAKED ENAMEL FINISH. PROVIDE gOMIN. N � US/RM SPEC TS OCTRON c U TYPE 0 Z 1400 LUMEN BATTERY PACK FOR NL FIXTURES. A2 LSI-QLS G A 3 32 5D 55010 LB841 3 3-Fo32/841/ECO 120 I ELECTRONIC 89 RECESSED 2X4 ACRYLIC FLUORESCENT WITH FLANGE FOR SAME AS FIXTURE TYPE 'A' EXCEPT PROVIDED M U5/FK-24/RM SPEC T8 OCTRON U O GWB CEILING WITH FLANGE MOUNTING OPTION. C) r-- 120V CFL 132T UE C27 120V O CO = N 4 PROVIDE WITH 0.125" DROPPED PRISMATIC B LSI-QLS PALC LMP 841/RM SPEC I CF32DT/E/841 120 1 ELECTRONIC 32 RECESSED RECESSED FLUORESCENT DOWNLIGHT. POLYCARBONATE LENS. PROVIDE gOMIN 1400 cc LL. V � • "T-URYPF.IYTiJgL4. C L5I-QL5 X5L2-5A-LED-50-55-CW- I LED 120 - - 60 RECESSED 18X18 RECESSED LED DOWNLIGHT IN CANOPY. LED SOFFIT LIGHT. ILLUMINATION OF LIGHT I 1 120 -DFL M � U L FIXTURE NO GREATER THAN 10 FOOTCANDLES. ca BLACK INCANDESCENT PENDANT LIGHT D SEAGULL (olg40-782/RM SPEC 1 25W AN 120 - - 25 PENDANT FIXTURE IN DINING ROOM. PROVIDE AMBER MOUNT +5'-6"AFF. W GLOBE. F LSI-QLS 5 3 32 55010 WG240 LM841 2 3-FO32/841/XPS 120 1 ELECTRONIC 56 SURFACE 2 -LAMP, 4' FLUORESCENT STRIP LIGHT. PROVIDE WIRE GUARD. UE/RM SPEC /EGO T8 OCTRON G LSI-QLS 12014 CFL 132T US C27 120V 1 CF32DT/E/841 120 I ELECTRONIC 32 RECESSED RECESSED WALL WASH FLUORESCENT 8" APERATURE HORIZ. MOUNTED LAMP, ALZAK CL WW LMP841/RM SPEC DOWNLIGHT. REFLECTOR. I OAI L51 GBWS-FT-10-120- 1 IOOW MH 120 1 ELECTRONIC 100 WALL NC FULL CUTOFF METAL HALIDE WALL SCONCE. IE-cA T LU IN MHOUSING. CEA TEMPERED GLASS LENS. NET BUFF/RMM SPEC FACTORY PAINTED TO MATCH EIFS. LOCATION LABEL. f FULL CUTOFF METAL HALIDE WALL SCONCE DIE-CAST ALUMINUM HOUSING. CLEAR f LSI BWS-FT-100-M14-F-120-BUF 1 IOOW MH 120 I ELECTRONIC 100 WALL WITH INTEGRAL PHOTOCELL. FACTORY PAINTED TEMPERED GLASS LENS. NET -PCI120/RM SPEC TO MATCH EIFS, f LOCATION LABEL. kA2 f FIXTURE NOT USED. LSI-QLS 2WP-5.4/RM SPEC 2 - - - - 6W HALOGEN - - 120 - - - - - - - NONE - - 15 - - - - WALL - ----..- EXTERIOR EMERGENCY LIGHT. WET LOCATION LABEL. SUPPLY WITH REMOTE MOUNTED EMERGENCY BATTERY PACK FOR gOMIN. OPERATION. POLYCARBONATE HOUSING WITH ®�I LSI -OLS EX R U W 120/277 EM/RM SPEC - LED 120 - NONE 2.5 UNIVERSAL LED EXIT SIGN. SELF-CONTAINED POWER PACK FOR 001 gOMIN. OPERATION. NICAD BATTERY. WHITE HOUSING. RED LETTERS, L5I-QL5 HEM W 120/277 EM/RM SPEC 2 7.2W HALOGEN 120 - NONE 20 WALL INTERIOR EMERGENCY WALL PACK. POLYCARBONATE HOUSING WITH SELF-CONTAINED POWER PACK FOR CIOMIN. OPERATION. WHITE HOUSING. NOTES: 1. ALL FLUORESCENT LAMPS SHALL BE T8 OCTRON XP5/ECO 4100K AS SPECIFIED. ALL FLUORESCENT BALLASTS SHALL BE AS SPECIFIED. SUBMITTAL SHEETS SHALL BE SUBMITTED WITH FIXTURE SUBMITTALS. FLUORESCENT LAMP AND BALLAST WARRANTY SHALL BE COMPLETED BY CONTRACTOR AND TURNED OVER TO OWNER AT END OF PROJECT. 2. ALL INCANDESCENT LIGHT FIXTURES SHALL HAVE A U.L. LABEL INDICATING THAT THE LAMP WATTAGE SPECIFIED ABOVE 15 THE MAXIMUM ALLOWABLE IN FIXTURE. 3. ALL 3 AND 4 LAMP ELECTRONIC BALLASTS SHALL HAVE INBOARD/OUTBOARD SWITCHING AS INDICATED ON THE DRAWINGS. TANDEM FIXTURES ARE ALLOWED TO FACILITATE INBOARD/ OUTBOARD SWITCHING. 4. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS. 5. ALIGN ALL HORIZONTAL FLUORESCENT DOWN LIGHTS 50 THAT THE COMPACT FLUORESCENT LAMPS ARE ALIGNED IN THE SAME DIRECTION. 6. ALL METAL HALIDE LAMPS SHALL HAVE A CRI OF NOT LESS THAN 70. 7. ALL ELECTRONIC BALLASTS FOR T5(5/8" DIAMETER) LAMPS AND BELOW SHALL HAVE END OF LIFE SHUTDOWN PROTECTION 8. PROVIDE LOW -TEMP (0°F MINIMUM) BALLA5T(5) FOR ALL FIXTURES INSTALLED IN EXTERIOR LOCATIONS OR OTHER AREAS SUBJECT TO COLD WEATHER. q. SUSPEND TWO OPPOSITE CORNERS WITH WIRE TO STRUCTURE. DO NOT ALLOW GRID ALONE TO SUPPORT FIXTURES. 10. ALL EMERGENCY LIGHTS TO BE EQUIPPED WITH A LOCAL MEANS OF TESTING LIGHT FUNCTION WITHOUT DISASSEMBLY OF LIGHTING FIXTURES OR SWITCHING OFF ENTIRE LIGHTING CIRCUITS. 11. SEE CIVIL SHEET Cq FOR 51TE LIGHTING SPECIFICATIONS AND 51TE POLE LOCATIONS. ALL 51TE LIGHTS TO BE PROVIDED, WIRED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. N ■ ■ ■ ■ ■ ■ ISSUE DATE: 7-15-16 REVISION O REVISION 2: -- O 3: -- REVISION W PROJECT #: 15-197-000 CONTENT: ELECTRICAL ti co 4 MO O ti 0 N � 0 c U 0 Z 0 N L M U O C) r-- .1-0 O CO = N 4 O • L cc LL. V � • U) _ c t V o L M � U L ca 70 U) W ISSUE DATE: 7-15-16 REVISION 1: 12-19-16 REVISION 2: -- REVISION 3: -- REVISION 4: -- PROJECT #: 15-197-000 CONTENT: ELECTRICAL SCHEDULES PROJECT SABER ENGINEER DRAWN BY: RPL CADD FILE NAME: E S D -1642-E01. dwg THIS DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY OF ESD. THE REPRODUCTION, OR USE OF THIS DRAWING WITHOUT THEIR WRITTEN CONSENT IS PROHIBITED, ANY INFRINGEMENT IS SUBJECT TO LEGAL ACTION. Sheet E-1 ■ ■ ■ ■ C NO C-21, ESD-1642—EO2.dwg, Plotted By. ryan _ Dec 19. 2016 — 11: 41 am STUB 1" CONDUIT TO LANDSCAPING FOR IRRIGATION CONTROLLER. COORDINATE W/ SPRINKLER INSTALLER. O ---------1 2 J OPTIONAL DUMPSTER ENCLOSURE ELECTRICAL PLAN 1/4 Of= i I -C NOTES: 1. SEE SITE PLAN FOR EXACT LOCATION OF ENCLOSURE. Hm Km 11'-6"AFF TO BOTTOM NOTES• 1. SEE SITE PLAN FOR EXACT LOCATION OF ENCLOSURE. 2. STORAGE ROOM IS EXCLUDED IN ALTERNATE #2. J -BOX FOR CANOPY LIGHTING (BY OTHERS) TO BOTTOM v Vv v CKT VIA T'STAT EXTEND 1" COND TO SH FOR FUTURE SECURITY CONNECTION. C-1 r STUB 1" CONDUIT TO LANDSCAPING FOR IRRIGATION CONTROLLER. COORDINATE W/ SPRINKLER INSTALLER. THE ARCHITECT/ENGINEER DOES NOT DEFINE THE SCOPE OF INDIVIDUAL TRADES, SUBCONTRACTORS, MATERIAL SUPPLIERS, OR VENDORS. ANY SHEET NUMBERING SYSTEM USED WHICH IDENTIFIES DISCIPLINES IS SOLELY TO SEPARATE ARCHITECT'S AND ENGINEER'S SCOPE; IT DOES NOT DEFINE A SUBCONTRACTOR'S SCOPE OF WORK. NO CONSIDERATION WILL BE GIVEN TO REQUESTS FOR CHANGE ORDERS FOR FAILURE TO OBTAIN AND REVIEW THE COMPLETE SET OF DRAWINGS AND SPECIFICATIONS. C-17 11'-CAFF TO BOTTOM A 01 FLOOR PLAN -LIGHTING 1 /4'0=10-00) F —c=F zIII 1*3 NO COMBUSTIBLE MATERIALS ALLOWED WITH 18" OF KITCHEN HOODS. ALL PIPING LOCATED IN WALLS BEHIND HOODS, AND WITHIN 1T OF HOOD, SHALL BE CONSTRUCTED OF NONCOMBUSTIBLE MATERIALS. ;-24---1-1----- 1 I I I 1. ALL 2X4 LIGHT FIXTURES ARE TYPE 'A' UNLESS OTHERWISE NOTES. 2. SEE REFLECTED CEILING PLAN FOR EXACT LIGHT FIXTURE LOCATIONS. 3. CONNECT ALL EMERGENCY AND EXIT LIGHT FIXTURES TO NEAREST UNSWITCHED LEG OF LOCAL LIGHTING CIRCUIT, TYPICAL FOR EACH. 4. ROUTE CIRCUIT TO LIGHT POLES. VERIFY LOCATIONS WITH SITE CIVIL DRAWINGS. 5. ROUTE CIRCUITS TO ROAD SIGNAGE. VERIFY LOCATION WITH SITE CIVIL DRAWINGS. 6. ROUTE CIRCUIT TO MENU BOARD SIGN. VERIFY LOCATION WITH SITE CIVIL DRAWINGS. 7. PROVIDE 120V CONNECTION FOR BUILDING SIGN. 8. SWITCH BANK FOR LIGHTS IN RESTAURANT. E.C. SHALL LABEL EACH SWITCH FOR THE LIGHTS IN CONTROLS. 9. ALL EMERGENCY LIGHTS, TYPE 'NL' FIXTURES ARE TO BE WIRED AS UNSWITCHED, NIGHT LIGHTS, TYPICAL FOR EACH. M A-6,8 NOTE 4 NOTE 5 C-28,30 m- C-29,31 C-25,27 2923 South Tryon Street Suite 280 Charlotte, North Carolina 28203 tel 704.373.0068 fax 704.373.0260 MECHANICAL ELECTRICAL PLUMBING OP 0717"m 7 Dec 19, 2016 Al REVISION 1 CHANGES: - DELETED ALL TYPE 'OB' CANOPY MOUNTED UPLIGHTS. - RELOCATED/RESPACED ALL TYPE 'OA1' AND 'OA2' WALL MOUNTED LIGHT FIXTURES. ■ O O 0') r` cY) 4 Co O O r'- CN `N oo W N E = U 0 ai Z � � e O N L C6 O 0 O L O ti O C'') = N .� (D O G1 X L (B 0) LL f+ 0) C E (6 E O L � � C-) Cz r� N C/) U) Q) E W ■ ■ ■ ■ Z Q w p C!) 1 0 LLj Lu C:)Z 0 � C/)�w w 00 CD `V � O � J Q = Q = O U m ISSUE DATE: 7-15-16 REVISION 1: 12-19-16 REVISION 2: -- REVISION 3: -- REVISION 4: -- PROJECT #: 15-197-000 CONTENT: ELECTRICAL LIGHTING PLAN PROJECT SABER ENGINEER DRAWN BY: RPL CADD FILE NAME: ESD-1642-E02.dwg THIS DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY OF ESD. THE REPRODUCTION, OR USE OF THIS DRAWING WITHOUT THEIR WRITTEN CONSENT IS PROHIBITED, ANY INFRINGEMENT IS SUBJECT TO LEGAL ACTION. Sheet E-2 ■ ■ ■ ■ ■