HomeMy WebLinkAboutWPO200700068 Plan - E&S Erosion Control Plan 2009-01-08ALB"EMARLE COUNTY, VIRGINIA 5 �f Service A6 rity w � w LEGEND:VICINITY MAP (1 --2000') - -- ..._ ._- -_- __ .._ ..,'< .'.-. __. __ __...._...._..__ .-.- _- __ Existing Sanitary Sewer and Manhole PROPOSED SANITARY SEWER AND MANHOLE PROPOSED SANITARY LATERAL CONNECTIOI`V F7 NS - -57 VZ_ NST/LL A VENUME ZE0_0!' L 7 E PROPOSED STEEL CASING PIPE O CARRSSROO/f Z OR/VE ash. PROJECT PROPOSED LIMITS OF CLEARING AREA PROPOSED PERMANENT UTILITY EASEMENT (SECTION 2) — — — PROPOSED TEMPORARY CONSTRUCTION EA;SLMENT Q �� (BY OTHERS) } Existing Fiber Optic Marker 7 Existing Light Pole Existing Gate Valve SOUTHERN ST ,- Existing Water Meter RaLLROAo -- Existing Signs _ Existing Mail Box v� ST -- Existing Power Pole & Guy Line 5� / FREE AZ? bt-a1fEFlcLO —� 1 RO"40 Existing Telephone Pedestal -.. 1 _.-.-.--- --. Existing Fiber Optic Existing Overhead Power PROJECT - ------ ------ ------- - Existing Cable T.V. AREA Existing U/G Telephone 29 HUIi (SECTION 1) __. Existing U/G Eiectirc rinicr�v Existing Waterline Existing Guard Rail Existing Storm Sewer i CMP fir,P Existing Edge of Pavement v Q Existing Survey Control Point �o Existing Treeline ROUTE- 290 BYp`` ss"+y'"" Existing Force Main Existing VDOT Monument 5,F Existing Rod Found 250 ------ Existing Right—of—Way/Property Line 'z Existing Deciduous Tree Q� m Existing Coniferous Tree NOTE: CONTRACTOR TO CONTACT MISS UTILITY (1-800-532-7001) AT LEAST 3 WORKING DAYS IN ADVANCE OF PLANNED WORK. U a These documents, including drawings and specifications, were prepared by Draper Aden Associates, Consulting Engineers, pursuant to a cortract by and between Draper Aden Associates and the Albemarle County Service Authority with respect to the project described in said contract. Any reuse or modification of said documents (whether hard copy or electronic) without written verification or adaptation by Draper Aden Associates for .the specific purpose intended will be at the sole risk of the individual or entity utilizing said documents, drawings and specifications and such use is without the authorization of Draper Aden Associates.. Draper Aden Associates, Consulting Engineers, shall have no legal liability resulting from any and all claims, damages, losses, and expenses, including attorney's fees arising out of the unauthorized use of these documents, drawings, specifications, reports, and studies prepared as a result of the aforesaid contract. iAW . ............1 K up EROSION AND SEDIMENT i. PLANS i DETAILS !, ARE NOT USED IN THIS PiORTION OF THE PROJECT. OWNER. ALBEMARLE COUNTY SERVICE AUTHORITY 168 SPOTNAP ROAD CHARLOTTESVILLE, VIRGINIA 22911 PHONE: 434-977-4511 ENGINEER: DRAPER ADEN ASSOCIATES 700 HARRIS ST., SUITE E CHARLOTTESVILLE, VIRGINIA 22903 PHONE: 434-295-0700 DRAPER ADEN ASSOCIATES 8090 VILLA PARK DRIVE RICHMOND, VIRGINIA 23228 PHONE: 804-264-2228 rD �. � �9 � 1� 4315 j L.r CS t;? ': i„��i��! ✓11�. i:,° ,�..� it ���e�✓F ; }', r r — S-. 1 114 DRAPER ADEN ASSOCIATES REVIEW THESE PLANS HAVE BEEN SUBJECTED TO TECHNICAL AND QUALITY REVIEWS BY: NAMIE: PRINTED PROJECT DESIGNER NAMIE: PRINTED PROJECT MANAGER r NAMIE: PRINTED QUALITY REVIEWER SIGNATGRE SIGNATURE ; fl`l,t`iLi SIGNATURE REVISIOIN HISTORY 06-18-07 Per ACSA Comments 07-27-07 Per ACSA Comments 09-11-07 Per ACSA Comments 10-11-07 Revised Inverts at MH 15 08-26-08 Realignment to avoid 2419 Hunt. 9/8/08 PER ACSA DATE DATE: September 8, 2008 PROJECT NUMBER: CV 6167- 2 DATE W 0. 1 j rr UJ Z Z LLI ln� LLJ C) > .J F_ sus Cr LL c� LJJ J cc • LJ� < :E 0 IE REVISIOIN HISTORY 06-18-07 Per ACSA Comments 07-27-07 Per ACSA Comments 09-11-07 Per ACSA Comments 10-11-07 Revised Inverts at MH 15 08-26-08 Realignment to avoid 2419 Hunt. 9/8/08 PER ACSA DATE DATE: September 8, 2008 PROJECT NUMBER: CV 6167- 2 DATE NOTES: T H 0, H oj 1. CONTRACTOR TO COORDINATE INSTALLATION OF SANITARY SEWER TO 6" STUB OUT ACCOMMODATE USE OF DRIVEWAYS THAT ARE TO BE DISTURBED. TM 062AI-00-OA-00400 PROPOSED ELLEN F. HAWKINS 2414 HUNTINGTON RD. Tray. N/S #35 x� STORM SEWER 11,N TI N 'T So 6� z (BY OTHERS) DB 1806/588 6.04 > N 391304 -LA. LARSON MICHAEL 2. LIMITS OF CONSTRUCTION/CLEARING SHALL BE WITHIN THE LIMITS OF E 11492741.04 , A.1111 00 No. 0358 PERMANENT EASEMENT.TBM "W" N 3912930,7 XAL Nail in 18" Tree Elev.= 452.62 if \ \ ~=`\x;S 3. CONTRACTOR TO FIELD VERIFY LOCATION OF ALL EX. UTILITIES TO E '11493159.2 11114�:5umr_ 10 MINIMUM VERTICAL SEPARATION IbILIVVILLIN SANITARY FIFL�� TBIVI "A" / \Tray. N /F 0,, 'D WATER OR STORM SEWER PIPES. FF= 458.33 x REMOVE ANU Nail in Power Pole V 391 -P REINS!, Elev.= 461.32 E 93 F, 0 1?0p -e RT AND 4� ALL PIPE LENGTHS (L) ARE GIVEN AS HORIZONTAL DISTANCES C 0 D WAY -7 u "0 A' BETWEEN INSIDE FACES OF MANHOLES. PAVEM ',, q 5. 3 FT. MINIMUM COVER REQUIRED OVER CENTERLIINE OF PIPE (TYP.) .• ' 6. ANGLES BETWEEN SEWER LINES ARE AS SHOWN IN PLAN VIEW. V V,- 7. TREES TO BE REMOVED IN EASEMENT ARE SHOWN DARKER THAN CL Fi-av FNYI,3 #64 THOSE NOT TO BE REMOVED. con 07 IN 39' '3 `98. 11,48,' 01.50 ..... ..... Vi xi$ting srrlh" A' " " ' ". ' ' / _' 'i i / �, / ! , ij � � � IF t 431 51 F "/, 'Z, IF 0,P_ . ...... CONCRETE DITCH Inv in: Z / ", 0 RE WHE IMPACTED DURING + t: 42 J, 4/, IF F F ` i' ` F -Z ` / F, . 1 1 ,,� i� -�L , , �.�'d v Fl, I I p 42 1 r7 1�7 i) CON TRUCTION N 3,91 F] 14100i; _ \.-:.... 1- / a.y --------- -------- ----------- - - .... ... 169*05'25"" IF N, -'k Ff Ff < iF: C4 MH 11-A FROM IF F; F OR T �S,, IQ L J. IF W&W ASSOCI�A 0 m Tray. N #34 4 F'b,tE F : - I i ; '' , �! I! F, F, , - -, N 39175184.88 IF "y CA81NG It." PLANS BELVEDERE 11492776�01 WALL,; -ii Al ,j , A v", fF 5 C, DEVELOPMENT ;fH ---- ------ V lCkNt, '15" Steel Inv. Od 431,70 J F TIGHT ANHbLE TEM • CONSTRUCTION _EASEMENT U­cT1 Oa - F, PORARY PROPOSED STORM SEWER ( Y BY OTHERS) 'F 201 PERM AN EN T- F f -EASEMENT-- _TS OF -'CLEARING. TMP 61 -00-00-1 `7 LIMI DUNLORA LLC 174* E Et TM 062AI-00-OK-01700 MARK T. or SHERRI DONNELLY 2406 WAKEFIELD ROAD D13 2249/320 -D 1-1 / 1'4 1 ri r- 11 11 U Z_ LIIVII 1 3 t,)r k-UI143 I MUU I IUI'4/ �,LL/-\MIINkj -\LL nt:- VVI 1r1I L V I r A ------ I Wy PERMANENT EASEMENT. No.035858 Trav/ 3820.82 N 691, E 11492792.04 A. 3. CONTRACTOR TO FIELD VERIFY LOCATION OF ALL EX. UTILITIES TO 01VA L DB 2074/269N Qj// lb Ex, Drop Inlet - Top= 445.7 Inv. in 437.41 (18"N) 10' TEMPRAR Ir)V.0U 437.20, t= (18"S) CONSTRUCOTION Y "U, ev EASEMENT, _ REPAIR-- ---- -- DRIVEWAY PAWM ENT 2 11c- ---------- 77 7- -9 otl� Co Ditc'h, _7 _NG TON ROA WWII 'Jl x '96'2 Z Z", , x X 0" 777 7,777777�, T 51 81*, W, 89-29'41" Z U z . ..... . .... .. Y RI ("S" 5 t t RE x", x x> 6, x R JR E �A D qc Trov. N #50 -- -------- . ..... Trov. V #12 N 391,380 0.82 Trov. N/S #51 T13M "B" 1\1 3913723.89 E 1149 306 6.4-1 j a I , Tray. E 11493000,82 Nail in P�ower Pole N 3913527�69 N Elev.= 468,16 N 3913373 32 E 11492954.14 E 11492874.1 40+00 41 + 00 42+ OCA 43+00 + Q0 S 480 480 Oi LLJ 0 +a. to Z Z ,0 4- 0 CN c'! to co STUB OUT FOR EXISTING 06 C5 to EMPTY LOT GRADE 0 + + CL +a in - cq LL — �` `� SEWER ,,,_ .�- .� 115.85 RRY LLJ to 0) aaaaaaaaaaaaaaaa 500;- SANS STUB OUT 460 4 60 0 w CONNECTION FOR ........2412 WAKEFIELD CONCRETE AW&AMW LL 0 > CL I LLJ F— z ---ANCHORS. SEE Z) 0 0 Z Lij _1 DETAIL SHEET 11 .J LO coq LJJ 27.15 LIF 8" DUCTILE IRON + n® a. SANITARY SEWER 0 32.41% 06-17-2007 Added MH 11A 06-17-2007 Added Limits 0 0 CN co 05-02-08 Removed Easement LID C 5 140 CO(O (03 00 't vt LATERAL 0 0rn co z z CONNECnON FOR + CL 2408 %AKEFIELD C14 0 63.117. SF*F-F, LATERAL,; CONNECTION FOR 2406 WAKEFIELD -- ----- --- U)LO z L0 0 z 0 co (0 c) 06 0 cr) 4 Lia+ zz LID +0- +0- z Loo d... to -qt R ... ...... . 0 C-4 0 EXISTING LATERAL 0* 0 Q- GRADE STREAM C ROSSING CONCRETE CONNECTION FOR + + C14 0 "R-" ANCHORS. SEE 2419 HUN TINGTON DETAIL SHEET 11 INVERT IN AT 449.4 FROM MANHOLE 10 87.27 LF 8" PVC SDR -35 103.14 LF 8" DUCTILE IRON SANITARY SEWER 0 0.57% SANITARY SEWER 0 1.07% ON 00 tr) U-) 00 0 04 Lo 0 0 U') 00 LO LOLO 3.0' MIN. LO co 00 10- 00 > > > > LEARANCE > > > > > Z z z z zlz z z z 40+00 41 + 00 42+ OCA 43+00 + Q0 S 480 480 Oi LLJ 0 +a. to Z Z ,0 4- 0 CN c'! to co STUB OUT FOR EXISTING 06 C5 to EMPTY LOT GRADE + + CL +a in - LL — �` `� SEWER ,,,_ .�- .� 115.85 RRY LLJ Z aaaaaaaaaaaaaaaa < SANS STUB OUT 460 4 60 0 w CONNECTION FOR ........2412 WAKEFIELD CONCRETE AW&AMW LL 0 > CL I LLJ F— z ---ANCHORS. SEE Z) 0 0 Z Lij _1 DETAIL SHEET 11 .J O� U LJJ 27.15 LIF 8" DUCTILE IRON z co SANITARY SEWER 0 32.41% 06-17-2007 Added MH 11A 06-17-2007 Added Limits 0 0 CN 07-27-07 Moved Lat. for 2417 out of MH. 05-02-08 Removed Easement LID C 5 140 CO(O (03 00 't vt 440 440 z z z DESIGNED BY: MAL DRAWN BY: TDS CHECKED BY: 440 MAL SCALE: HORZ: 1"= 25' VERT: V= 10' DATE: September 8, 2008 PROJECT NUMBER: CV06167-02 4,B LL LLJ Z aaaaaaaaaaaaaaaa < < 0 ^ z % 0 w CE AW&AMW LL 0 > CL I LLJ F— z 06 Z) 0 0 Z Lij _1 .J O� U LJJ z co REVISIONS 06-17-2007 Added MH 11A 06-17-2007 Added Limits of Clearing 07-27-07 Moved Lat. for 2417 out of MH. 05-02-08 Removed Easement 08-28-08 Realignment to avoid 2419 DESIGNED BY: MAL DRAWN BY: TDS CHECKED BY: 440 MAL SCALE: HORZ: 1"= 25' VERT: V= 10' DATE: September 8, 2008 PROJECT NUMBER: CV06167-02 4,B Uj 0 LLj U_ Q Uj �0 Lai In W fv (U fp a r"v CU £. m, L7W ! .-r u S U Y ^ CU "u LL Ld w D Q z^ Nd P4 BLit+a+LO £ ItU u (U �� U L- m� J ^z❑ i 0 L %D E tri uti i o o J i C$ 0 Lal � 0 a m oD tL Uj 0 ,-,ulE: d r, " z 9QE:< P1 E: aE O = oo Ln Y F= t0� A� Nu Inmo LU C� EZ U) a � �o a �z �D u n w Sr CU £ N �00 to� fl v a (U ON \ � A E � CU A , Ui "� �u N� �u �u1 Lli1 a LTC ILL TYPICAL MANHOLE FRAME & COVER NTS FIG SA -D Effective August 18, 2005 TD -4 3000 PSI CONC. BASE BENCH SLOPED TO FLOW CHANNEL 1/4" : 1' MIN L 4 a, i �o ,11 \ �� + --0 BRANCH 12" - -„- -� 1 J Q 2" FLEXIBLE CONNECTION --�LJ NOTE: WITH STAINLESS STEEL ALL CONNECTIONS TO BAND EXISTING MANHOLES SHALL BE CORED AND A FLEXIBLE CONNECTION " BOOT o INSTALLED TYPICAL MANHOLE PLAN SHOWING BRANCH TIE — IN NTS FIG. S -I -B TD -2 r� G 1' C25MM1 East Jordan Iran Works 00103971 D (4) 1' C25mm) DFA HOLES ON 32 3/4" C834Mw) DIA BOLT CIRCLE. 2' (51MM) LETTERS <RECESSED FLUSH) �- CAM BOLT SEE ASSEMBLY IIETAIL _ 27 1/2' DIA 1 1/2' 1699MM] 13$MM] 7' 26 1/4' DIA C178MM3 1667MM] 24' DIA # . t606MM] 28 7/16' DTA 5/8' j 1722MM] 116MM] 36' DIA _ 26' 1914MM] 1660MMl 1 1/2' FRAME SECTION 13/16' 138MM] C20MM] 1 0 1 1{ 1 2 1/8' _ C54MMl 0 11/16' C17MM] 3 13/16' C97MMJ 1 3/8' C35mml 3 1/8' 1 179MM] 113MM] 0 22 13/16' C579MM] 0 25' C635MM] 9/16" ®.D, OF GKT GROOVE 114MM7 SECTION VIEW 1/4' (6MM) DIA NEOPRENE GASKET (2) WSHR 1/16 X 5/8 X 1 1/2 C2) CORED 1800' RUBBER PART# 00981045 W P[CKBARS CSMM] 1 5/8" PAR B# D0981250LT HEX 8-11X3 lf2 SS 2400" C41MMJ FADE IN USA 1/2" (2) WSHR 5/8 ID 1,50 OD SS .1 1/8' C29MM) DIA BOSS 16MM7 C13Mre] 63 DIA. STAINLESS STEEL ROD PART# 00981318 PLAN VIEW PICKBAR & LOCKLUG HOLE DETAIL NOTES: (2) NUT HX 5/8-11 ZN NYLK PART# 00981284 1. ALL MANHOLES WITHIN 100 YEAR FLOODPLAIN OR LOCATED IN AREAS SUBJECT TO FLOODING SHALL HAVE WATERTIGHT FRAME &COVER. (2) NUT HX JAM 5/8-11 ZN 2. ALTERNATIVE DESIGN FOR WATERTIGHT COVERS WILL BE CONSIDERED. PART# 00981228 3. COVERS SHALL BE FIXED TO FRAMES WITH LOCKING LUGS OR SIMILIAR ASSEMBLY. TYPICAL WATERTIGHT- A �l�fSAT E RT I HT C2) 19358 LOCK LUG (SHDRT) PART# 00I93585 MANHOLE FRAME COVER LOCK Luc ASSEMBLY Effective August 18, 2005 NTS FIG S+E FRAME & COVER (SEE FIG. S-I-D,E) SLOPED AREA STREET SURFACE OR NON -PAVED AREA l'-0" MAX 2'-0" "WEDG--LOK" TYPE BACKFILL SHALL RUBBER COATED STEEL a o STEPS OR APPROVED 3'-0" MIN EQUAL CAST IN PLACE LARGER THAN 5" IN ANY PRECAST REINFORCED CLEANOUT CONCRETE SECTIONS 1 2" MIN "0" RING SEALS 16)" MAX }--6" MINIMUM ELEVATION a 1,-0" DIFFERENCE ACROSS M.H. 5" 4'-0" 5' FROM INLET TO OUTLET (6" LIFTS) SHALL BE 01.20 FEET. CONCRETE 4 VARIES DEPTH OF FLOW FILLETS a CHANNEL TO BE _ 3/4 DIAMETER OF OF PIPE CONTRIBUTING - -- =-� - MECHANICAL TAMPER SEWER.' A -� d ,1 � 12" A FILLETED INVERT FOR A SMOOTH NO. 68 STONE TRANSITION OF FLOW BETWEEN SERVICE LATER INLET & OUTLET PIPE SHALL BE PROVIDED. -- MIN. 6" BEDDING NOTE : W/ NO. 68 STONE 1. BEDDING THICKNESS REQUIREMENT SHOWN IS MINIMUM AND SHALL BE SPECIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. 2. THE CONSULTANT WILL DETERMINE WETHER MANHOLES SHALL HAVE EXTENDED OR NON -EXTENDED BASES. < 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED & GROUTED INSIDE AND OUT. TYPICAL MANHOLE SECTION , SHOWING BRANCH TIE-IN NTS FIG. S -I -A TD -1 NOTE 1.OPEN CUTS 1N PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE BACKFILLED ACCORDING TO VDOT PAVEMENT REPAIR DETAIL. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO. 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWED PIPE INSTALLATION IN TRENCH NTS FIG. S-3 TD -7 SLOPED AREA --' 2'-0" - - 1'-0" MAX �Z� 0- a FRAME & COVER SEE FIG. S -I -D, E STREET SURFACE OR NON -PAVED AREA "WEDG LOK" TYPE RUBBER COATED STEEL STEPS OR APPROVED EQUAL CAST IN PLACE PRECAST REINFORCED CONCRETE SECTIONS WITH "0" RING SEALS OR APPROVED EQUAL 3'--0" MIN o THE DROP CONNECTION SHALL BE DUCTILE IRON PIPE (CLASS 50) a 5" BACKFILLED IN 6" LAYERS AND COMPACTED BY HAND TAMPERS OR 12' MIN BACKFILLED WITH SELF -COMPACTING 16" MAX STONE. o 5" MINIMUM ELEVATION DIFFERENCE 12"MIN 12"MIN ACROSS M.H. FROM INLET TO VARIE o Q OUTLET SHALL BE 0.20 FEET A FILLETED INVERT FOR A SMOOTH TRANSITION OF FLOW BETWEEN INLET & OULET PIPE SHALL BE a� /\ PROVIDED. 12" D ZS- D A.- C D D n' D- 3/4 DIA OF LARGEST PIPE IN MANHOLE MIN, 6" BEDDING WITH NO. 68 STONE NOTES: 1. BEDDING THICKNESS REQUIREMENTS SHOWN ARE MINIMUM AND SHALL BE SPEiCIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. 2. THE CONSULTANT SHALL DETERMINE WHETHER MANHOLES SHALL HAVE EXTENDED OR NON -EXTENDED BASES. 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED & GROUTED INSIDE AND OUT. 4. SPECIAL CONSIDERATION SHALL BE GIVEN FOR ENTRANCE DESIGN ON SEWERS WITH STEEP SLOPES. f NTS FIG. S -I -C TD -3 THREADED PLUG CLEANOUT ADAPTOR BACKFILL SHALL _REMAINING NOT CONTAIN ROCK MATERIAL 4„ 36 MIN LARGER THAN 5" IN ANY VDOT NO. 21A STONE CLEANOUT DIMENSION 24"MI }--6" 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE 1,-0" INTIAL BACKFILL* _IT 8"MIN (6" LIFTS) EMBEDMENT PIPE CONNECTED TO THE MANHOLE. Uj 2. ALL SEWER SERVICE LATERAL CONNECTIONS INCLUDING THOSE * THOROUGHLY COMPACTED SPRING LINE BY HAND OR APPROVED OF PIPE PER FOOT). MECHANICAL TAMPER 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM DIAMETER OF 4". HAUNCHING NO. 68 STONE X_ SERVICE LATER BEDDING 6" max 4" min — FOUNDATION (SHALL BE REQUIRED WHEN SOIL < CONDITIONS ARE UNSTABLE z ALL PIPE) NOTE 1.OPEN CUTS 1N PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE BACKFILLED ACCORDING TO VDOT PAVEMENT REPAIR DETAIL. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO. 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWED PIPE INSTALLATION IN TRENCH NTS FIG. S-3 TD -7 SLOPED AREA --' 2'-0" - - 1'-0" MAX �Z� 0- a FRAME & COVER SEE FIG. S -I -D, E STREET SURFACE OR NON -PAVED AREA "WEDG LOK" TYPE RUBBER COATED STEEL STEPS OR APPROVED EQUAL CAST IN PLACE PRECAST REINFORCED CONCRETE SECTIONS WITH "0" RING SEALS OR APPROVED EQUAL 3'--0" MIN o THE DROP CONNECTION SHALL BE DUCTILE IRON PIPE (CLASS 50) a 5" BACKFILLED IN 6" LAYERS AND COMPACTED BY HAND TAMPERS OR 12' MIN BACKFILLED WITH SELF -COMPACTING 16" MAX STONE. o 5" MINIMUM ELEVATION DIFFERENCE 12"MIN 12"MIN ACROSS M.H. FROM INLET TO VARIE o Q OUTLET SHALL BE 0.20 FEET A FILLETED INVERT FOR A SMOOTH TRANSITION OF FLOW BETWEEN INLET & OULET PIPE SHALL BE a� /\ PROVIDED. 12" D ZS- D A.- C D D n' D- 3/4 DIA OF LARGEST PIPE IN MANHOLE MIN, 6" BEDDING WITH NO. 68 STONE NOTES: 1. BEDDING THICKNESS REQUIREMENTS SHOWN ARE MINIMUM AND SHALL BE SPEiCIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. 2. THE CONSULTANT SHALL DETERMINE WHETHER MANHOLES SHALL HAVE EXTENDED OR NON -EXTENDED BASES. 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED & GROUTED INSIDE AND OUT. 4. SPECIAL CONSIDERATION SHALL BE GIVEN FOR ENTRANCE DESIGN ON SEWERS WITH STEEP SLOPES. f NTS FIG. S -I -C TD -3 THREADED PLUG CLEANOUT ADAPTOR FINISHED GROUND ADJUSTABLE VALVE BOX WITH LID. BINGHAM & 4„ TAYLOR FIG. NO 4905 OR APPROVED EQUAL VDOT NO. 21A STONE CLEANOUT NOTE SEWER SERVICE LATERAL CONNECTION NOTES }--6" 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE 1,-0" AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED, _IT THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE 0.2" HIGHER THAN THE TOP (CROWN) ELEVATION OF THE LOWEST PIPE CONNECTED TO THE MANHOLE. Uj 2. ALL SEWER SERVICE LATERAL CONNECTIONS INCLUDING THOSE CONNECTED TO MANHOLES SHALL HAVE CLEANOUTS AS INDICATED. 3. GRADE FOR SEWER SERVICE CONNECTIONS SHALL BE 2% (1.4" Uj PER FOOT). 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3'. PLUG END OF X_ SERVICE LATER PROVIDE D.I. TO PVC TRANSITION FITTING AS REQUIRED. 45.9 �-- MAIN LINE LID WITH THE MARKING SEWER CAST IN. IN LINE WYE -TEE PLAN AS INDICATED Ll e M O f TD -6 NLTH 0`1 MICHAEL A. LARSON No. 035858 ONAL�� 4-4> rJi yj ap.4 > 0 * a � E a 0 3: Cn a �y 7 + gwC4 >� 'y L '> x A _hoc 0;:� DESIGNED BY: ACSA DRAWN BY: ACSA CHECKED BY: MAL SCALE: NOT TO SCALE DATE: September 8, 2008 PROJECT NUME3ER: rr Uj 3: Uj z < z h rj I— Uj z LLW cc Uj C)Lli 120 <t DESIGNED BY: ACSA DRAWN BY: ACSA CHECKED BY: MAL SCALE: NOT TO SCALE DATE: September 8, 2008 PROJECT NUME3ER: O.D. 12" CONCRETE ENCASEMENT VDOT CLASS 1 RIPRAP SECTION A- A NOT TO SCALE O D 3.0' MIN. LENGTH (VARIES) iN ! MATCH EXISTING PROFILE 1 EXCEPT WHERE SLOPE OF AX. BANK BANK EXCEEDS 1 TO 1 A a I— `'�—�.�T UNDISTURBED MATERIAL A ELEVATION NOTES: 1. WHERE LESS THAN 3' OF COVER IS AVAILABLE BELOW STREAMBED, CONCRETE ENCASEMEN WILL BE REQUIRED. 2. WHEN BEDROCK IS ENCOUNTERED AND COVER EQUALS OR EXCEEDS 3', THE TRENCH SHALL BE BACKFILLED WITH COMPACTED 21A STONE AND TOPPED WITH 18" OF VDOT' CLASS 1 RIPRAP. SEWER TYPICAL STREAM CROSSING N.T.S FIG. S-7 rW, VENT PIPE— ONE AT EACH END OF CASING (SEE NOTES) 8'-0' MIN. -------- ---tJ 5'-6' MIN, I I DUCTILE IRON PIPE (MECHANICAL JOINT) 25' MIN, ALSO SEE THE "AREA MANUAL FOR RAILWAY ENGINEERING — PART 5, PIPELINES" RAILROAD 2'-0' 1 2'-0' 1 17' LIR 8' VENT PIPE— ONE AT EACH END OF CASING (SEE NOTES) COATED STEEL BAND OR STAINLESS STEEL CASING INSULATORS AS MANU— FACTUED BY ADVANCE PRODUCT SYSTEMS, INC., MODEL SS1, S7; OR BY CASCADE MODEL #CCS -905, OR APPROVED EQUAL. STEEL CASING -� wwtlfs r - �Imlwml 18' OR 20' JOINT OF D.I. SIGN e 0 12" CONCRETE FILL BOTH ENDS NOTE, 1, ENDS OF CASING CAN BE SEALED USING MODEL AC PULL—LIN END SEAL GASKET, AS MANUFACTURED BY ADVANCE PRODUCT SYSTEMS, INC., IN LIEU OF CONCRETE FILL, 2. MIDDLE SPACER SHALL BE PLACED AT THE CENTERPOINT OF PIPE. SEWER TYPICAL STEEL SLEEVE INSTALLATION UNDER RAILROADS N.T.S FIG. S-6 SIGNa 1. PIPELINE SHALL BE PROMINENTLY MARKED AT RIGHT—OF—WAY LINES (ON BOTH SIDES OF TRACK FOR CROSSINGS) BY DURABLE, WEATHERPROOF SIGNS LOCATED OVER THE CENTERLINE OF THE PIPE. 2. SIGNS SHALL BE MIN 30" X 36" AND CONTAIN THE FOLLOWING TEXT: NON—PRESSURIZED GRAVITY SANITARY SEWER LINE LOCATED XX.X FEET BELOW GROUND OWNED AND OPERATED BY: AL13EMARLE COUNTY SERVICE AUTHORITY 168 SPOTNAP RD. CHARLOTTESVILLE, VA 22911 IN CASE OF EMERGENCY CALL: 434-977-4511 NOTE: "XX.X" TO BE ACTUAL PIPE DEPTH BELOW GRADE AT SIGN LOCATION. CASING VENT PIPES 1. VENT PIPES SHALL BE OF SUFFICIENT DIAMETER, BUT NO LESS THAN TWO INCHES IN DIAMETER, AND PLACED NEAR EACH END OF THE CASING AND PROJECT THROUGH THE GROUND SURFACE AT RIGHT—OF—WAY LINES OR NOT LESS THAN 45 FEET, MEASURED AT RIGHT ANGLES FROM CENTERLINE OF THE TRACK. 2. VENT PIPES SHALL EXTEND A MINIMUM OF 4' ABOVE THE GROUND SURFACE. 3 TOP OF VENT PIPE SHALL HAVE A TURNED DOWN ELBOW, PROPERLY SCREENED, OR A RELIEF VALVE. 4 VENTS IN LOCATIONS SUBJECT TO HIGH WATER SHALL BE EXTENDED ABOVE THE MAXIMUM HIGH WATER ELEVATION AND SHALL BE SUPPORTED AND PROTECTED IN A MANNER APPROVED BY NORFOLK SOUTHERN. 5 VENT PIPE SHALL CLEAR ANY AERIAL ELECTRICAL WIRES BY 4 FEET MINIMUM, OR GREATER IF REQUIRED BY NATIONAL ELECTRICAL SAFETY CODE (ANSI C2). MILL EXISTING PAVEMENT TO MIN. 165 LB/SQYD MIN. 1.5" OVERLAY ASPHALT CONCRETE SURFACE sCOURSE TYPE (SM). VDOT BM ASPHALT CONCRETE_ BASE COURSE TO MATCH EXISTI�gG PAVEMENT SECTION (6" MINIMUM) UNDISTURBED SUBGRADE APPROVED SOIL OR SELECT MATERIAL TYPE 1, CBR 30 COMPACTED TO 95% - MAX DENSITY AT OPTIMUM MOISTURE CONTENT STRAIGHT SAW CUT IN EXISTING PAVEMENT MIN 10" TYPE 1 SIZE 21 A or 8 AGG. COMPACTED TO 100% MAX. DENSITY AT OPTIMUM MOISTURE CONTENT SAND OR NO. 57 STONE FOR PIPE LESS THAN 12" THE TRENCH WIDTH MAY BE 36" MAXIMUM. SEE UB -1 (ROAD AND BRIDGE STANDARDS VOLUME 11) VDOT CUT REPLACEMENT PAVEMENT REPAIR DETAIL NOT TO SCALE SAW CUT EXISTING PAVEMENT 8ff BEDDING AND INITIAL BACKFILL AS PER PROJECT DRAWINGS AMD SPECIFICATIONS. 2" SM -2A COMPACTED VDOT 21B AGGREGATE SELECT BACKFILL COMPACTED TO 95% MAXIMUM DENSITY TR NE CH WIDTH AS PER SPECIFICATIONS PANED DRIVEWAY PRIVATE ROAD REPAIR NOT To scALE Iii q1,1 ' fl. MICHAEL A. LARSON NQ. 035858 w eu cti REVISIONS 09-11-2007 Added Backfill Noir to VDOT 12-23-08 Per Add #1 DESIGNED BY: ACSA DRAWN BY: ACSA CHECKED BY: MAL SCALE: NOT TO SCALE DATE: September 8, 2008 PROJECT NUMBER: V061 7-0 qqj- w vi ui cn z F - UJ z Lu UJ 00 REVISIONS 09-11-2007 Added Backfill Noir to VDOT 12-23-08 Per Add #1 DESIGNED BY: ACSA DRAWN BY: ACSA CHECKED BY: MAL SCALE: NOT TO SCALE DATE: September 8, 2008 PROJECT NUMBER: V061 7-0 GENERAL CONSTRUCTION NOTESFOREROSION AND SEDIMENT CONTROL PLANS �NlTH of t THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PROJECT DESCRIPTION nrF PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND ISTURBINGTHIS PROJECT CONSISTS OF THE CONSTRUCTION OF PUBLIC SANITARY SEWER FOR THE ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. NORTHFIELDS AREA DEVELOPMENT - PHASE 4. THE TOTAL AREA OF LAND DISTURBANCE 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ASSOCIATED WITH THIS PROJECT IS 1.06 ACRES. MICHAEL A RSON ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND EXISTING CONDITIONS No. 035858 SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND THE EXISTING SITE CONSISTS OF CURRENTLY UNDEVELOPED AND RESIDENTAL PROPERTIES 1 / 1. SET POSTS AND EXCAVATE A 2, STAPLE WIRE FENCING TO THE POSTS. SEDIMENT CONTROL REGULATIONS. LOCATED WITHIN THE UPPER RIVANNA RIVER WATERSHED. TOPOGRAPHY AND VEGETATION 0" 4" X 4" TRENCH UPSLOPE EXISTING ALONG THE LINE OF POSTS. 70' MIN. Ai 5:1 PAVEMENT 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE VARIES AS SHOWN ON THE PLANS. DRAINAGE IS TO TOWN BRANCH CREEK. -10NAL 110A FIRST STEP IN CLEARING. ADJACENT PROPERTIES THE SUBJECT PROPERTY IS BORDERED GENERALLY TO THE WEST BY WAKEFIELD ROAD, TO 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE EAST BY THE NORFOLK SOUTHERN RAILROAD NEAR MP 109, TO THE SOUTH BY RIO FILTER2 6" MINT MOUNTABLE BERM THE SITE AT ALL TIMES. ROAD, AND THE NORTH BY FREE STATE ROAD. EXISTING AJ Awma CLOTH (OPTIONAL) 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON CRITICAL EROSION AREAS GROUND w < SIDE ELEVATION THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF-SITE BORROW OR WASTE AREAS), THE -CARE MUST BE TAKEN TO MINIMIZE SEDIMENTATION OF THE EXISTING TOWN BRANCH 0 r7 CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR CREEK. EROSION CONTROL DEVICES MUST BE INSTALLED AND MAINTAINED TO PROMOTE REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. PROPER FUNCTION. 0 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL TION VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADS, 70' MIN. -WHERE CONSTRUCTION MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN 10' MIN, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY (VEHICULAR) WASHRACK APPROVING AUTHORITY, TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC FLOW,/' -(OPTIONAL) N ROAD SURFACES, THE ROAD SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. ti 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL \4� _ i I � k__ I--- SEDIMENT SHALL BE REMOVED FROM THE ROADS BT SHOVELING OR SWEEPING AND TIMES DURING LAND DISTURBING AC 10' MIN. STABILIZATION IS ACHIEVED. TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL 12' MIN. 4. BACKFILL AND COMPACT TING TIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING APPLY TO INDIVIDUAL SUBDIVISION LOTS AS WELL AS TO LARGER LAND DITHERS EXIS 8. DURING DEWATERING OPERA ACTIVITIES. A CONSTRUCTION ENTRANCE MUST BE INSTALLED TO SERVICE THE SITE THE EXCAVATED SOIL. 3. ATTACH THE FILTER FABRIC PAVEMENT DEVICE. + CONSTRUCTION. P. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER -EXISTING CULVERTS TO REMAIN MUST BE PROTECTED TO PREVENT SEDIMENT DEPOSIT OR EXTEND IT INTO THE TRENCH. TO THE WIRE FENCE AND VDOT #1 B EACH RUNOFFPRODUCING RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN POSITIVE DRAINAGE THE EFFECTIVENESS OFTHE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. "SILTING -UP" OF THE PIPES. COURSE 10' MIN. AGGREGATE TO SEDIMENT VESCR MS -16 UNDERGROUND UTILITY LINE INSTALLATION TRAPPING DEVICE 4= MUST EXTEND FULL WIDTH 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING OF INGRESS AND EGRESS 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL PLAN VIEW STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: 4�4 OPERATION BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME, 4 E V 12' MIN. 3" MIN. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UP HILL SIDE OF TRENCHES. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER > C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH ZONING ORDINANCE SECTION 5.1.28. kj; FLOW'AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER -SITE PROPERTY. THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE D. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN S4 CODE OF ALBEMARLE. ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. EXTENSION OF FABRIC E. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. AND WIRE INTO THE SECTION A- 3" MIN. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE A F. COMPLY WITH APPLICABLE SAFETY REGULATIONS. TRENCH. FILTER CLOTH LIMITED TO THE HOURS OF 7: OOAM TO 9:OOPM. 6'-7„ 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAN STRUCTURAL PRACTICES VESCH STD. & SPEC. NUMBER CONSTRUCTION ENTRANCE #3.02 MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL SILT FENCE #3.05 FILTER FABRIC DAMAGE TO ADJACENT LAND AND IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE v #3.08 CULVERT INLET PROTECTION V 0 SLIDES, SINKING, OR COLLAPSE. OUTLET PROTECTION 18 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO J, PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL 7 MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR VEGETATIVE PRACTICES A TOPSOILING #3.30 OTHER PORTION OF THE PROPERTY. #3.31 TEMPORARY SEEDING c, ,4 CONSTRUCTION OF A SILT FENCE (WITH WIRE SUPPORT)17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE PERMANENT SEEDING #3.32 REINFORCED SECTION 13-13 DRAIN SPACE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX MULCHING #3.35 CONCRETE TREE PROTECTION AND PRESERVATION #3.38.39 OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF DUST CONTROL #3 ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO w BE APPLIED AT 80LBS/10OSF. ALTERNATIVES ARE SUBJECT TO APPROVED BY THE COUNTY (n SILT FENCE 3 N� STONE CONSTRUCTION ENTRANCE CE EROSION CONTROL INSPECTOR. SEQUENCE OF CONSTRUCTION < 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND 1, ALL EROSION CONTROL MEASURES AND A PRECONSTRUCTION MEETING SHALL BE NAULCH, AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED AHEAD OF CONSTRUCTION WORK. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, RNTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT IOOOLBS/ACRE AND SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSIST OF A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT COMSTRUCTED AS A FIRST STEP IN ANY LAND DISTURBING ACTIVITY AND SHALL BE MADE 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL FUNICTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/1OOSF. ALTERNATIVES ARE SUBJECT TO APPROVED BY THE COUNTY EROSION CONTROL INSPECTOR, 2. BEGIN AS SHOWN ON THIS PLAN. 19. MAINTENANCE: ALL MEASURES ARE TO BE INSPECTED WEEKLY AND AFTER EACH RAINFALL. 3. MAINTAIN EROSION CONTROL MEASURES THROUGHOUT INITIAL CONSTRUCTION WORK. ui ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES IS TO BE REPAIR IMMEDIATELY. SILT IN GENERAL, ALL ESC MEASURES WILL BE CHECKED DAILY AND AFTER EACH TRAPS ARE TO BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. SIGNIFICANT RAINFALL. ALL SEEDED AREAS ARE TO BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH ARE COLLECTING SEDIMENT TO HALF THEIR 4. NO OFFSITE LAND DISTURBING ACTIVITIES ARE PLANNED. ANY OFFSITE LAND HEIGHT MUST BE CLEANED AND REPAIRED DISTURBANCE ACTIVITIES WILL REQUIRE A SEPARATE LAND DISTURBANCE PERMIT BY THE IMAM EDI ATELY. CONTRACTOR. ENDWALL 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE REMOVED WITHIN 5. ALL TEMPORY EROSION CONTROL AND SEDIMENT CONTROL MEASURES SHALL BE 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO REMOVED EAWITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY - - - - - - - - -- - - APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. SURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM ADMINISTRATOR. TRAPPED SEDIMENT AND THE DISTURBED SOIL ATREAS TOE OF FILLY RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY < CULVERT STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. FLOiOD PLAIN Z DRIP LINE SHALLOW THIS PROPERTY LIES WITHIN FLOOD ZONE "C", FIRM, COMMUNITY PANEL NUMBERS: 51003 SLOPE< z 0279D. FLOOD ZONE "X" IS DEFINED AS "AREAS OF MINIMAL FLOODING". (NOT A HUD I IFLOW ON SHALLOW SLOPES, STRIPS OF 100 YEAR FLOOD ZONE) (n cr NETTING PROTECTIVE COVERINGS MAY j SNOW FENCE BE APPLIED ACROSS THE SLOPE. STORMWATER MANAGEMENT > THE UTILITY EXTENSIONS WILL NOT CAUSE A SIGNIFICANT INCREASE IN IMPERVIOUSNESS OR PEAK RUNOFF LATES AND NO STORMWATER TREATMENT >: IS REQUIRED. ALL OPEN WATER CHANNELS WILL BE PROTECTED FROM EROSION SEDIMENTATION DURING CONSTRUCTION. W z ui PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS OMNI& 0 WHERE THERE IS A BERM AT THE U. BERM WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. Li 0 0 TION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED TOE OF FILL TOP OF THE SLOPE, BRING THE TEMPORARY SOIL STABILIZATION w 0 -1 AMATERIAL OVER THE BERM AND AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT (UNDISTURBED) "," N - cc ANCHOR IT BEHIND THE BERM. f FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS SILT FENCE DISTANCE IS 6MINIMUM IF THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. ' FLOW IS TOWARD C0 w EMBANKMENT f STEEP IFLOW BOARD FENCE ui CORD FENCE SLOPE' 4lfl0. APPLY PROTECTIVE ON STEEP SLOPES I REVISIONS OPTIONAL STONE COMBINATION ��LPLASTIC FENCE COVERING PARALLEL TO THE DIRECTION 06-18-2007 CORRECT METHODS OF TREE FENCING OF FLOW AND ANCHOR SECURELY. 1,0' Changed EC -3 to EC -2 TOTAL LBS 11-18-08 GENERAL SLOPE U O= R I zi, PER -ACRE Per E&S Comments 2 1.5:1 MAX KENTUCKY 31 FESCUE 128 LBS. 17771 nr c P GRASS e " 2 LBS. M.4 2,5 SEASONAL NURSE CROP FLOW BRING MATERIAL DOWN TO A LEVEL J'S 20 LBS- AREA BEFORE TERMINATING THE INSTALLATION. TURN THE END UNDER 150 LBS ".-12 P SEASONAL NURSE CROP 'n 4" AND STAPLE AT 12" INTERVALS. Lu FEBRUARY 16 THROUGH APRIL ANNUAL RYE VDOT #3, #357, #5, #56 OR #57 COARSE CLASS I RIPRAP DITCH FLOW MAY 1 THROUGH AUGUST 15 FOXTAIL MILLET DESIGNED BY: AGGREGATE TO REPLACE SILT FENCE IN 03 AUGUST 16 THROUGH OCTOBER ANNUAL RYE 5 MAL 0 HORSESHOE WHEN HIGH VELOCITY OF FLOW IS IN DITCHES, APPLY PROTECTIVE < POO NOVEMBER THROUGH FEBRUARY 15 WNTER RYE DRAWN BY: 9 EXPECTED COVERING PARALLEL TO THE 9 DIRECTION OF FLOW. USE CHECK NOTEI CORRECT TRUNK ARMORING CHECKED BY: TDS TRIANGULAR BOARD FENCE SLOTS AS REQUIRED. AVOID JOINING > MATERIAL IN THE CENTER OF THE 1. LIME AND FERTILIZER NEEDS SHALL BE DETERMINED BY SOIL TESTS AND APPLIED IN MAL SCALE: DITCH IF AT ALL POSSIBLE. ACCORDANCE WITH VESCH STD. 3.32. SILT FENCE CULVERTNTS TREE PROTECTION TP f OIP 2. SEEDINGS TO BE MULCHED IMMEDIATELY UPON COMPLETION OF SEED APPLICATION, IN DATE: INLET PROTECTION ACCORDANCE W/ VESCH STD 3.35. November 18, 2008 PROJECT NUMBER: E 0 3. DUST CONTROL SHALL BE DONE IN ACCORDANCE WITH VESCH STD. 3.39 CV06167-02 EC - TYPICAL ORIENTATION OF TREATMENT (SOIL STABILIZATION BLANKET Ps ES3 PERMANENT STABILIZATION