Loading...
HomeMy WebLinkAboutSDP200500047 Plan - Approved Minor Amendment 2005-11-29MINOR AMENDMENT TO SITE DEVELOPMENT PLANS FOR WOOLEN MILLS WAREHOUSES TM 77 PARCEL 40 DB 2909 PAGE 623 RIVANNA DISTRICT, ALBEMARLE COUNTY, VIRGINIA SITE DATA LEGAL REFERENCE: TM 77 PARCEL 40 SOURCE OF TITLE FOR PARCEL 40: DB 2909 PAGE 623 OWNER: CHRISTOPHER CARTER P.O. BOX 174 IVY VA, 22945 DEVELOPER: C.W. HURT CONTRACTORS 195 RIVERBEND DRIVE CHARLOTTESVILLE VA, 22911 ZONING: LI - LIGHT INDUSTRIAL APPROVED SP: SP2000-25 MAGISTERIAL DISTRICT: SCOTTSVILLE SOURCE OF BOUNDARY SURVEY: BOUNDARY SURVEY PERFORMED BY B. AUBRY HUFFMAN & ASSOCIATES, LTD. SOURCE OF TOPOGRAPHY: FIELD SURVEY PERFORMED BY RIVANNA ENGINEERING AND SURVEYING, PLC. USGS DATUM. BENCHMARK: NAIL IN POWER POLE F204 ELEVATION 332.25 BUIDLING SETBACKS: 50' FROM PUBLIC R/W PARKING SETBACKS: 10' FROM PUBLIC R/W MAXIMUM BUILDING HEIGHT: 35' PAVING SPECIFICATIONS: PARKING AREA: 6" - #21A AGGREGATE BASE MATERIAL 2" - SM 9.5 SURFACE MATERIAL SIDEWALKS: 4" - 3000 PSI CONCRETE CURRENT USE: BREAD WAREHOUSE PROPOSED USE: BREAD WAREHOUSE FLOOR AREA RATIO: 41.4% TOTAL IMPERVIOUS AREA: 41,275 PARKING SCHEDULE: PARKING SPACES REQUIRED: 1 PARKING SPACE PER 500 SF OPEN TO THE PUBLIC: 3000 SF / 500 SF = 6 PARKING SPACES 1 PARKING SPACE PER EMPLOYEE 10 EMPLOYEES = 10 SPACES TOTAL SPACES REQUIRED = 16 TOTAL SPACES PROVIDED = 16 (INC 2 HANDICAP) LOADING SPACES REQUIRED: 0 LAND USE SCHEDULE: Existing Waterline --0/E-- Overhead Electric •' PRE -DEVELOPMENT % POST -DEVELOPMENT % BUILDING: 6,000 SF 8.5 9,375 SF 13.3 PAVED: 23,200 SF 33.0 31,900 SF 45.3 PERVIOUS 41.149 SF 58.5 29.074 SF 41.4 TOTAL: 70,349 SF 100 70,349 SF 100 GENERAL NOTES 1. DO NOT SCALE THESE DRAWINGS. USE DIMENSIONS SHOWN ONLY. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ENGINEER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL DIMENSIONS. 2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES. 3. THE SPILLOVER OF LIGHTING FROM OUTDOOR LUMINAIRES ONTO PUBLIC ROADS AND PROPERTY IN RESIDENTIAL OR RURAL AREAS ZONING DISTRICTS SHALL NOT EXCEED ONE-HALF (1/2) FOOT CANDLE. 4. EACH OUTDOOR LUMINARIE EQUIPPED WITH A LAMP WHICH EMITS 3,000 OR MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINARIE AND SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS AND AWAY FROM ADJACENT ROADS. 1. THIS MAJOR SITEPLAN AMENDMENT SHOWS AMENDMENTS TO THE WOOLEN MILLS WAREHOUSES SITE (SDP 98-32). THE PURPOSE OF THIS MAJOR AMENDMENT IS FOR AN ADDITION TO THE EXISTING BUILDING AND ASSOCIATED PARKING. 2. STORM WATER DETENTION IS NOT REQUIRED AS THIS SITE IS IN THE MOORES CREEK DRAINAGE BASIN (MORE THAN 100 TIMES THE DISTURBED AREA). STORMWATER QUALITY SHALL BE PROVIDED BY AN ONSITE STORMWATER QUALITY SWALE. 3. MAXIMUM NUMBER OF EMPLOYEES SHALL BE 10. 4. THE EXISTING SIGN SHALL REMAIN. 5. THE 100 YEAR FLOOD PLAIN IS AT THE 330 ELEVATION ON THIS SITE. 5. THIS SITE IS NOT LOCATED IN A RESERVOIR WATERSHED. 7. TRASH REMOVAL: EXISTING DUMPSTER. 8. EXISTING LANDSCAPING CONSISTS OF DECIDUOUS WOODED AND GRASSED AREAS. 9. SITE LIGHTING SHALL BE PROVIDED BY WALL MOUNTED FIXTURES WITH AN OUTPUT THAT SHALL NOT EXCEED 3,000 LUMENS. 10. PARCELS 40 & 40R SHALL BE COMBINED PER PLAT BY B. AUBREY HUFFMAN AND ASSOCIATES DATED NOVEMBER 19TH, 2004. GENERAL WATER & SEWER CONDITIONS 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER SERVICE AUTHORITY OFFICIALS AT THE START OF THE WORK. 2. THE LOCATION OF EXISTING UTILITIES ARE NOT NECESSARILY SHOWN ON THE PLANS AND, WHERE SHOWN, ARE ONLY APPROXIMATE, THE CONTRACTOR SHALL LOCATE ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. \ 3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS AS ADOPTED BY THE ALBEMARLE COUNTY SERVICE AUTHORITY ON JANUARY 15, 1998. 4. DATUM FOR ALL ELEVATIONS SHOWN IS ASSUMED F.F. ELEV. OF DENNIS ENT. BUILDING (500') FROM PRIOR SURVEY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING "MISS UTILITY" (1-800-552-7001). 6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF 3 FEET OF COVER, MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF THE PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES. 7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL PAVING, DRAINAGE RELATED MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF V.D.O.T., UNLESS OTHERWISE NOTED. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 4:1 OR BETTER ARE TO BE ACHIEVED. 5. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE ALBEMARLE COUNTY DIRECTOR OF ENGINEERING, OR THE DIRECTOR'S DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 7. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 8. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926) DRAWING INDEX 1 of 2 COVER SHEET 2 of 2 SITE PLAN LEGEND Benchmark --W/E-- Existing Waterline --0/E-- Overhead Electric •' Power Pole PLAINNING DEPARTMENT Exist Light Pole -0 Prop. Light Pole MH Manhole C/O Clean-out 500 Existing Elevation/Contour x [500] Proposed Elevation 500 Proposed Contour PLAINNING DEPARTMENT Slopes Greater Than 25% ZONING DEPARTMENT New Concrete Sidewalk INSPECTIONS DEPARTMENT/FIRE Existing Concrete Sidewalk APPROVALS PLAINNING DEPARTMENT ZONING DEPARTMENT INSPECTIONS DEPARTMENT/FIRE OFFICIAL SERVICE AUTHORITY Reviewed and Approved by the Community Development DeparftnuWl ENGINEERING DEPARTMENT Date- e.✓'"' N Fite#i - s�or VIRGINIA DEPARTMENT OF TRANSPORTATION BOARD OF ARCHITECTURAL REVIEW FIRE OFFICIAL �4� o��ENLTH OF� P\1 � c TIMOTHY R. MILLER CERTIFICATE No. 30542 ti N0. I DESCRIPTION I DATE Sheet No: Slof2