Loading...
HomeMy WebLinkAboutSDP201700007 Action Letter 2017-04-03COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 April 3, 2017 Craig Kotarski Timmons Group 608 Preston Ave, Suite 200 Charlottesville, VA 22903 RE: SDP -2017-007 Lidl- Premier Circle- Initial Site Plan Mr. Kotarski: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final site plan for all or a portion of the site within one (1) year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final site plan. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. Approval of all easements for facilities for stormwater management and drainage control. Submittal of a tree conservation checklist with areas for tree preservation identified. The final site plan will not be considered to have been officially submitted until the following items are received: A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. A fee of $1,500. Please submit 8 copies of the final plans to the Community Development Department. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies (for ACSA, please submit 3 copies of construction plans directly to them, as stated in their comments). Once you receive the first set of comments on the final site plan, please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members: Albemarle County Engineering Services (Engineer)- 2 copies [Emily Cox; ecox@albemarle.org] Albemarle County Planning Services (Planner)- 3 copies [Megan Yaniglos; myaniglos@albemarle.org] Albemarle County Planning Services (Architectural Review Board)- 1 copy [Margaret Maliszewski; mmaliszewski@albemarle.org] Albemarle County Department of Fire Rescue- 1 copies [Robbie Gilmer; rgilmer@albemarle.org] Albemarle County Service Authority- See comments for number of copies [Alex Morrison; amorrison@serviceauthority.org] Virginia Department of Transportation- 1 copy [Adam Moore; Adam.Moore@vdot.virginia.gov] If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3004, myaniglos@albemarle.org. Sincerely, Principal Planner 2 r� 'AL � IRGS?at� County of Albemarle Department of Community Development Memorandum To: Craig Kotarski (Craig.Kotarski@timmons.com) From: Megan Yaniglos, AICP- Principal Planner Division: Planning Services Date: March 22, 2017 Subject: SDP -2017-007 Lidl- Premier Circle- Initial Site Plan The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Requirements: 1. The notification fee of $215 has not been paid. The initial site plan will not be approved until the fee is paid. 2. [32.5.2a] A portion of the parking lot along Premier Circle does not appear to meet the 10' setback. Revise so the parking is 10 feet from the right of way. 3. [32.5.2n] On Sheet C4.0, please show the areas within the building that will be utilized for retail use and warehouse uses, and include a label stating the square footage for each use which corresponds with the parking area calculations provided on the Cover Sheet. 4. [32.5.2n] Please state the proposed paving materials to be used on all walks, parking lots, and driveways. 5. [32.5.2n] Please provide verification that all outdoor lights proposed on site will be full cutoff luminaires. The spec sheets provided for each model do not indicate what cutoff classification each luminaire type falls under. 6. [32.5.2n] The lighting plan shows footcandle measurements that are higher than the maximum 0.5 footcandles permitted along the right-of-way. Please amend the light locations as necessary to bring the footcandle measurements into compliance with the regulations set forth in Section 18-4.17 of the Albemarle County Code. 7. [4.17.4] Please add a note to the lighting plan which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." [32.5.2p] Please add an additional column to the Plant Schedule on Sheet L2.0 which states the canopy coverage of each species of proposed landscaping in accordance with the Albemarle County Recommended Plants List. [32.5.2p] Please add an additional column to the Plant Schedule on Sheet L2.0 which states the specific vegetation type (i.e. Large Shade Tree, Small Ornamental Tree, etc.) of each species of proposed vegetation in accordance with the Albemarle County Recommended Plants List. 10. [32.7.9.5d] Street trees should be planted within the right of way. Revise so the proposed street trees are located in the right of way. 11. ARB's comments are extensive and may require a redesign of the site. Please be aware that there may be additional comments depending on how ARB comments are addressed. Also, the plan may need to go back through site review depending on how drastic the revisions are. Recommendation: 1. Remove the sign and sign landscaping from the site plan. The sign and associated landscaping is approved through the sign permit and not the site plan. You may need to apply for a Letter of Revision in the future if it remains on the plans, if the sign permit requires that the location and landscaping be revised. Please contact Megan Yaniglos at the Department of Community Development 296-5832 ext. 3004 for further information. Review Comments for SDP201700007 11nitial Site Plan Project Name: LIDL - 405 Premier Circle - Initial Date Completed: Friday, February 24, 2017 Department1DivisionfAgency: Review sus: Reviewer: Keith Huckstep —E CDD Inspections Requested Changes With 163 parking spaces provided, 7 of them need to be accessible parking spaces, only 6 are provided_ See table 1106.1(1) of } the 2012 VCC_ S P dated 216!17 Page: County of Albemarle Printed On: I 031222017 Review Comments for SDP201700007 11nitial Site Plan Project Name: LIDL - 405 Premier Circle - Initial Date Completed: Saturday, February 25, 2017 Department1DivisionfAgency: Review Sys: Reviewer: Robbie GilmerFire Rescue Requested Changes Based on plans dated 2J6/17- 1 _ Fire flow test required before final approval_ Please attach a copy to the final plans_ Page: County of Albemarle Printed On: I 031222017 Review Comments for SDP201700007 11nitial Site Plan Project Name: LIDL - 405 Premier Circle - Initial Date Completed: Monday, March 20, 2017 Department1DivisionfAgency: Review sus: Reviewer: Emily Cox El CDD Engineering Requested Changes -WM and E&S. sheets should not be included in the site plan set_ They are part of the VMPJUVPO Plan- -Provide a legend for the plans- -Ensure all critical slopes are shown on the plan- -Provide a detail for the retaining wall- -Ensure entrances meet all VDOT requirements (sight distance, radii, etc) and do not exceed a 4% grade for a distance of 40' from the intersected street (County Code Seciton 18 -4 -12 -17)- -The sidewalk abutting parking should be 6' wide (or bumper blocks provided) per the Design Standards Manual Section 7_ C_ 6- -Provide a dumpster pad detail- -Provide proof of permissionleasement, etc for work off of the property_ Page: County of Albemarle Printed On: I 031222017 Review Comments for SDP201700007 11nitial Site Plan Project Name: LIDL - 405 Premier Circle - Initial Date Completed: Monday, March 20, 2017 Department1DivisionfAgency: Review Sys: Reviewer: Margaret Maliszewski CBBARB I Requested Changes March 20, 2017ARBAction Motion: Mr_ Missel moved to approve the consent agenda and forward the recommendations outlined in the staff reports for the Initial Site Plans to the Agent for the Site Review Committee as follows - ARB -201T -OT: LIDL Premier Circle Initial Plan - Initial Site Plan (TM/Parcel 061M0000000600) Proposal: To construct a grocery store with associated site improvements Location: 405 Premier Circle, on the west side of Rt_ 29, approximately 300' north of Westfield Road Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and Initial Site Plan approval: The Initial Site Plan should not be approved until the following issues are resolved to the satisfaction of the APB 1_ Adjust planting area along the EC to avoid tree and utility conflicts- 2- Add planting area and trees along the north building elevation_ 3_ Revise the plan to orient the building parallel to the Entrance Corridor_ 4_ Revise the plan to reduce parking area located between the building and the EC_ 5_ Revise the plan to step the retaining wall where it is taller than 6'_ Provide planting along the wall and the terraces_ Regarding recommendations on the plan as it relates to the guidelines: None_ Regarding conditions to be satisfied prior to issuance of a grading permit: Revise the plan to show tree lines coordinated with proposed grading_ • Regarding the Final Site Plan: A Certificate of Appropriateness is required prior to final site plan approval_ The applicant shall submit for ARB review a revised plan addressing the following issues and all final site plan checklist requirements: 1_ Provide information showing that rooftop equipment will not be visible from the EC_ _ Show how the cart corral will be coordinated with the architectural design of the building_ 3_ Add the standard mechanical equipment note to both the site and architectural plans_ 'Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated-' 4_ Revise the luminaire schedule to clearly identify proposed fixture and pole colors A consistent color thrOLIghOLlt the development is recommended_ Dark brown, dark bronze, or black are appropriate colors 5_ Locate all proposed light fixtures on site_ 6_ Consider shifting tree locations to help reduce glare from parking lot pole light fixtures_ 7_ Coordinate the use of the W2 fixture throughout the site plan_ 8_ Add the standard lighting note to the plan_ 'Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads_ The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle-' 9_ Adjust planting area along the EC to avoid tree and utility conflicts_ 10_ Add planting area and trees along the north building elevation- 11- levation_11_ Increase shrub planting sizes to 24" for all shrubs at parking lot perimeters_ Add shrubs along the parking rows located along Premier Circle_ 12_ Revise plant quantities and increase variety so that no single tree or shrubs species exceeds 26% of the total proposed_ 13_ Revise the plan to orient the building parallel to the Entrance Corridor 14_ Revise the plan to reduce parking area located between the bLlilding and the EC_ 15_ Revise the plan to step the retaining wall where it is taller than 6: Provide planting along the wall and the terraces_ Page: 1 County of Albemarle Printed On: 03J22J2017 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 orange Road Culpeper. Virginia 22MI Charles A. Kilpatrick, P.E. Commissioner February 21, 2017 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Megan Yaniglos Re: LIDL (Premier Circle) — Initial Site Plan SDP -2017-00007 Review #I Dear Ms. Yaniglos: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Timmons Group, dated 6 February 2017, and offers the following comments: 1. As proposed construction routes stormwater to an existing drainage system within the Route 29 right-of-way please demonstrate that the existing system remains adequate in the post development condition from the "EX 1" structure to the outfall. Please note that as Route 29 is a principal arterial, the existing system must be analyzed under the 25 year storm. 2. Please provide right -turn lane warrant analysis with trip generation estimates for each entrance on to Premier Circle. Also provide warrant analysis confirming that the existing left turn lane on Route 29 has adequate storage for the increase in traffic due to the proposed redevelopment. 3. Note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Justin Deel at 434-422-9894. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING Megan Yaniglos From: Alexander Morrison <amorrison@serviceauthority.org> Sent: Thursday, March 23, 2017 8:17 AM To: Megan Yaniglos Subject: SDP201700007: Lidl - Initial Site Plan Megan, I have reviewed the above referenced plan and have the following comments: • Water Construction Plan Review will be required at the final site plan stage. Submit 3 copies of the plan along with a water data sheet to the ACSA, Attn: Michael Vieira, PE, to begin the review. • Provide water fixture counts so the water meter size can be verified. • Reconfigure the proposed water meter, fire line and fire hydrant. The fire hydrant must be at least 50' from the building. The water meter cannot be located within the thrust block of a fire hydrant. • Provide easements on the proposed water infrastructure. • There is an existing 3" water meter on site. • Add a valve before the proposed reducer and add notes that it will be cut in and restrained for isolation purposes before the new water main is installed. • Add notes to the existing water service and lateral that a disconnect must be witnessed by the ACSA prior to ACSA approval on a demolition permit. • Label the sewer extension as private. • Add notes for backflow protection on the domestic and fire services. Let me know if you have any questions. Alexander J. Morrison, P.E. Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434-977-4511 Ext. 116 (C) 434-981-5577 (F) 434-979-0698