Loading...
HomeMy WebLinkAboutSUB201700029 Review Comments Final Plat 2017-04-11County of Albemarle Department of Community Development Memorandum To: Gwen Lacy From: Paty Saternye- Senior Planner Division: Planning Services Date: March 13, 2017 Rev. 1: April 11, 2017 Subject: SUB -2017-29 James C. Arnold - Boundary Line Adjustment The County of Albemarle Planning Division will grant or recommend approval of the Final Plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [14-302(A)(9)] Building sites on proposed lots. Because of the small size of the proposed residue lot and the significant amount of critical slopes that are within the proposed lot area, provide an exhibit showing the 30,000 SQFT rectangle for the building area. Rev. 1: Comment Addressed. 2. [14-309 & 14-3101 Soils evaluations; health director approval. Provide the soil evaluations and health department approval for a primary and reserve drainfields for the 2 -acre residue lot.. Rev. 1: Comment not fully addressed. Soils work was submitted to the Health Department (VDH) on March 21, 2017. Approval or comments from the VDH have not vet been received. The Boundary Line Adjustment will not be approved until VDH approval. 3. [14-312] Location of existing buildings. If the second existing building on the residue lot is within 50 feet of the proposed lot line then show it on the plat. Rev. 1: Comment Addressed. 4. [14-312] Location of existing buildings. County GIS shows an additional structure within the existing T.M. 84-35G between the existing metal building and the property line, in the vicinity of the well. Provide information on whether that building exists. If the building exists, show it on the plat and dimension its distance to the parcel boundary lines. Rev. 1: Comment Addressed. 5. [14-312] Location of existing buildings. Provide a dimension from the existing mobile home to the proposed lot boundary at L7 & L8. Ensure that the required setback is being met. Rev. 1: Comment Addressed. 6. [14-312] Location of existing buildings. Provide information on the existing "metal building" that is 22.5 feet from the proposed property line on Parcel W. Specify if this is an accessory building. Ensure that the required setback is being met. Rev. 1: CommentAddressed. Please contact Pay a at the Department of Community Development 296-5832 ext. 3250 for further i f ation. i CC: James C. Arnold 2 County of Albemarle Department of Community Development Memorandum To: Gwen Lacy From: Paty Saternye- Senior Planner Division: Planning Services Date: March 13, 2017 Subject: SUB -2017-29 James C. Arnold - Boundary Line Adjustment The County of Albemarle Planning Division will grant or recommend approval of the Final Plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [14-302(A)(9)] Building sites on proposed lots. Because of the small size of the proposed residue lot and the significant amount of critical slopes that are within the proposed lot area, provide an exhibit showing the 30,000 SQFT rectangle for the building area. 2. [14-309 & 14-310] Soils evaluations; health director approval. Provide the soil evaluations and health department approval for a primary and reserve drainfields for the 2 -acre residue lot. 3. [14-312] Location of existing buildings. If the second existing building on the residue lot is within 50 feet of the proposed lot line then show it on the plat. 4. [14-312] Location of existing buildings. County GIS shows an additional structure within the existing T.M. 84-35G between the existing metal building and the property line, in the vicinity of the well. Provide information on whether that building exists. If the building exists, show it on the plat and dimension its distance to the parcel boundary lines. 5. [14-312] Location of existing buildings. Provide a dimension from the existing mobile home to the proposed lot boundary at L7 & L8. Ensure that the required setback is being met. 6. [14-312] Location of existing buildings. Provide information on the existing "metal building" that is 22.5 feet from the proposed property line on Parcel W. Specify if this is an �ytoye ces ry building. Ensure that the required setback is being met. Please contact P at the Department of Community Development 296-5832 ext. 3250 for further information. CC: James C. Arnold