Loading...
HomeMy WebLinkAboutARB201700070 Plan - Submittal (First) 2017-07-07fill D Fl D -8 RETAIL BUILDING t784 RIO HILL CENTER, CHARLOTTESVILLE, VA 22901 ARCHITECTURAL REVIEW BOARD SUBMITTAL ARCHITECT INTEC GROUP, INC. 214 W. TREMONT AVE. SUITE 301 CHARLOTTE, NC 28203 (704) 372-7910 OWNER/AGENT ROSENTHAL PROPERTIES C/O LAURENCE MCKENNY 1945 OLD GALLOWS ROAD VIENNA, VA 22901 STRUCTURAL ENGINEERING THE WATKINS PARTNERSHIP, INC 3032 MITCHELLVILLE RD SUITE 202 BOWIE, MD 20716 (410) 741-1791 EXISTING PROJECT EXTENTS EXISTING LOCATION PLAN SITE DRAWING INDEX PAGE SHEET NAME PAGE SHEET NAME GENERAL (3001 COVER SHEET ARCHITECTURAL A101 DEMOLITION PLAN, FLOOR PLAN A201 DEMOLITION ELEVATIONS, EXTERIOR ELEVATIONS, RENDERED ELEVATIONS ELECTRICAL PH001 LIGHTING AND PHOTOMETRIC PLAN INTEC Group, Inc. 214 W. TREMONT AVENUE S U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net PROJECT 1-4 0 m N N Lis >�o _~ �> luni �o 0 LL LIJ U Uj Uj W W �- J 0 w U J O ryH v- 00 n STAMP DRAWING LOG ISSUE: ARB SUBMITTAL DATE: 7171 17 SHEET INFORMATION DATE OF DRAWING: 717117 DRAWN BY: -- JOB NUMBER: 117101 COVER SHEET E NEW WORK PLAN LEGEND: (DEXISTING RAMP AND RAILING TO REMAIN (D EXISTING SIDEWALK TO REMAIN - REPAIR AS NEEDED O (D 1101106j, j EXISTING WALL TO BE DEMOLISHED EXISTING WALL TO REMAIN EXISTING DOOR, FRAME, HARDWARE I ALL RELATED TO BE REMOVED EXISTING DOOR TO REMAIN DEMOLITION PLAN KEY NOTE 7, AREA NOT IN SCOPE OF WORK DEMO FLOOR PLAN KEY NOTES: REMOVE EXISTING STOREFRONT SYSTEM INCLUDING ALL DOORS AND HARDWARE. CUT OPENING IN WALL FOR NEW STOREFRONT SYSTEM. REMOVE DOOR FRAME AND HARDWARE, REMOVE COLUMN AND WALL RETURN P] SEE DEMO ROOF PLAN AND DEMO ELEVATION PLAN FOR CANOPY/ ROOF MODIFICATIONS - TYPICAL Lov SCALE: 1/8" = 1'-0" 40'-2 3/4" 1 98'-I1 3/4" 10'-8 1/2" 19'-61/4" 29'-10" i 10'-7" 18'-S 3/4" 2913i, INTEC Group, Inc. 214 W. TREMONT AVENUE 5 U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net PROJECT STAMP DRAWING LOG ISSUE: ARB SUBMITTAL DATE: 7/7/17 SHEET INFORMATION DATE OF DRAWING: 7/7117 DRAWN BY: - JOB NUMBER: 117101 DEMOLITION PLAN, FLOOR PLAN A101 EXISTING WALL TO REMAIN NEW WALL - SEE GI.3 FOR PARTITION TYPES 66 NEW DOOR EXISTING OR RELOCATED DOOR ELEVATION MARKER DOOR TYPE oNEW SEE GI. FOR DOOR SCHEDULE <- PARTITION TYPE Ir SEE Gl. FOR PARTITION TYPES GNEW WORK PLAN KEY NOTE AREA OUTSIDE SCOPE OF WORK NEW WORK FLOOR PLAN KEY NOTES: (DEXISTING RAMP AND RAILING TO REMAIN (D EXISTING SIDEWALK TO REMAIN - REPAIR AS NEEDED O (D 1101106j, j EXISTING WALL TO BE DEMOLISHED EXISTING WALL TO REMAIN EXISTING DOOR, FRAME, HARDWARE I ALL RELATED TO BE REMOVED EXISTING DOOR TO REMAIN DEMOLITION PLAN KEY NOTE 7, AREA NOT IN SCOPE OF WORK DEMO FLOOR PLAN KEY NOTES: REMOVE EXISTING STOREFRONT SYSTEM INCLUDING ALL DOORS AND HARDWARE. CUT OPENING IN WALL FOR NEW STOREFRONT SYSTEM. REMOVE DOOR FRAME AND HARDWARE, REMOVE COLUMN AND WALL RETURN P] SEE DEMO ROOF PLAN AND DEMO ELEVATION PLAN FOR CANOPY/ ROOF MODIFICATIONS - TYPICAL Lov SCALE: 1/8" = 1'-0" 40'-2 3/4" 1 98'-I1 3/4" 10'-8 1/2" 19'-61/4" 29'-10" i 10'-7" 18'-S 3/4" 2913i, INTEC Group, Inc. 214 W. TREMONT AVENUE 5 U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net PROJECT STAMP DRAWING LOG ISSUE: ARB SUBMITTAL DATE: 7/7/17 SHEET INFORMATION DATE OF DRAWING: 7/7117 DRAWN BY: - JOB NUMBER: 117101 DEMOLITION PLAN, FLOOR PLAN A101 EXTERIOR FINISH SCHEDULE NO. j MATERIAL 1 SPECIFICATION I SPLIT FACE BLOCK COLOR TO MATCH EXISTING X , X 4' SPLIT FACE BLOCK COLOR TO MATCH EXISTING 4'. X16 X4 MOR INSULATED FINISH CORNICE AND ACCENT BANDS SYSTEM ( LIGHT COLOR) DRYVIT # 103, NATURAL WHITE SANDPEBBLE FINISH EXTERIOR INSULATED FINISH PRIMARY EIFS SYSTEM ( DARKER COLOR) DRYVIT # 473A, SAND SANDPEBBLE FINISH CE EXTERIOR INSULATED FINISH PILASTER EIFS SYSTEM( DARKEST COLOR) DRYVIT #113, 1 I�AMARI LED WHITE jSANDPEBBLE IRISH MATERIAL PALETTE MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING EIFS COLOR I DES COLOR 2 EIFS COLOR 3 DARK ROCK FACE BLOCK BRICK BLACK STOREFRONT SCOPE OF WORK I PREVIOUS -Y APPROVED PROJECT - NOW COMPLETE NEW WORK MATERIALS TO MATCH ACCORDINGU RENDERED ELEVATION - SOUTH 20 SCALE: NIS REMOVE PORTION OF EXISTING STANDING REMOVE PORTION OF EXISTING STANDING SEAM SEAM METAL ROOF/FASCIA AS INDICATED. METAL ROOF/FASCIA AS INDICATED. EXISTING EXISTING METAL TRUSS AND FRAME TO METAL TRUSS AND FRAME TO REMAIN. PREPARE REMAIN. PREPARE AREA TO RECEIVE NEW AREA TO RECEIVE NEW PEDIMENT. PEDIMENT. 4(E-2 3/4' 29'-10" REMOVE CANOPY METAL STUD AND REMOVE PARAPET COPING TO RECEIVE STRUCTURAL FRAMING IN M ENTIRETY NEW ROOF CONSTRUCTION. BETWEEN GRIDS 3 AND 4 - ROOF STEM WALL TO REMAIN 98'-11 3/4" 18`5 3/4' REMOVE EXISTING COPING AND PREPARE TO RECEIVE NEW PEDIMENT I T 29'-6 1/4" >1 +TOP OF PARAPET T 4 i T-� I- L"di 32'-3 "4�'PARAPET -1 A -I T P + 0 OF F 9`5" 31'4 o ITTI 71 FFI T I I I I 7- &i E-- TOP OF PARAPET Ll 1,1t Al I U j- I L1 I m "s -MIT E-1 1�4) 29'-10" REMOVE CANOPY METAL STUD AND REMOVE PARAPET COPING TO RECEIVE STRUCTURAL FRAMING IN M ENTIRETY NEW ROOF CONSTRUCTION. BETWEEN GRIDS 3 AND 4 - ROOF STEM WALL TO REMAIN 98'-11 3/4" 18`5 3/4' REMOVE EXISTING COPING AND PREPARE TO RECEIVE NEW PEDIMENT REMOVE PORTION OF EXISTING STANDING SEAM METAL ROOF/FASCIA/CEILING/ DOWNSPOUT. EXISTING METAL TRUSS AND FRAMING TO REMAIN. fi I FI F I- I F I -Fl -F-1 I I I F I TI I -L1 Ll I—L 1, 1 J 1 I Ll L 1-1-1 -1 1 T I 'A IS "A IL L _jL L ------ MASONRY PIER TO REMAIN. REMOVE EXISTING REMOVE PORTION 01 EXISTING TANDING 1. MET CLEAN AND PREPARE AS NEEDED. j STOREFRONT SYSTEM, ROOF/FASCIA AS INDICATED. STING METAL TRUSS UFRAME TO REMAIN AS FEASIBLE AFTER RREMOVAL OF STRUC'TU UP TO IT -O" WHICH IS NECESSARY FOR NEW CANOPY CONSTRUCTION. PREPARE AREA TO RECEIVE NEW PEDIMENT. /-� 2 DEMOLITION ELEVATION - SOUTH O SCALE: 1/8" = V-0" OFOPARAPET 32'-3/F OF OF PARAPET 31'-4 3/4' 4 1), 91 2) T I T >1 T 981-113/4- T 4 i T-� I- L"di 10'-8 1/2" -1 A -I 10'-7" 9`5" CUT OPENING IN 7- &i E-- FOR NEW STORE REMOVE PORTION OF EXISTING STANDING SEAM METAL ROOF/FASCIA/CEILING/ DOWNSPOUT. EXISTING METAL TRUSS AND FRAMING TO REMAIN. fi I FI F I- I F I -Fl -F-1 I I I F I TI I -L1 Ll I—L 1, 1 J 1 I Ll L 1-1-1 -1 1 T I 'A IS "A IL L _jL L ------ MASONRY PIER TO REMAIN. REMOVE EXISTING REMOVE PORTION 01 EXISTING TANDING 1. MET CLEAN AND PREPARE AS NEEDED. j STOREFRONT SYSTEM, ROOF/FASCIA AS INDICATED. STING METAL TRUSS UFRAME TO REMAIN AS FEASIBLE AFTER RREMOVAL OF STRUC'TU UP TO IT -O" WHICH IS NECESSARY FOR NEW CANOPY CONSTRUCTION. PREPARE AREA TO RECEIVE NEW PEDIMENT. /-� 2 DEMOLITION ELEVATION - SOUTH O SCALE: 1/8" = V-0" OFOPARAPET 32'-3/F OF OF PARAPET 31'-4 3/4' 4 1), 91 2) T TT 4 Q'-2 1/4" T T 981-113/4- T 1 10'-8 1/2" 29'-6 1/4" 29'-10" 10'-7" 9`5" 7- &i E-- E-1 1�4) fj fabric anI craft stores ELEVATION - SOUTH \A ZQ SCALE: 1/8" = V-10" ' NTEC Group, Inc. 214 W. TREMONT AVENUE S U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net PROJECT 1-4 0 a) z 0 ELi > F- v P-4 0 0 z g D < UJ = U- CY U >- 06 JU-11 LZL' U J -j r LL 0 �2 IT 00 rl I STAMP I DRAWING LOG ISSUE: ARB SUBMITTAL DATE: 7/7/17 SHEET INFORMATION DATE OF DRAWING: 7/7117 DRAWN BY: -- JOB NUMBER: 117101 ELEVATIONS A201 LIGHTING & PHOTOMTRIC PLAN H00 1/8" - 1'-0" LIGHTING FIXTURE SCHEDULE ID TYPE MFG MODEL LAMPLUMENS WATTS SIZE ll SERVES A LED LMhoni. VRR-LED-IL-FHL-120 1500 26 12'x 12"x 10' R Canopy Lighting NOTES 1) Coordinate voltage of fixture type Ain field to match voltage of existing calwpy fighting cirouR 2) Verify finishes, mounting heights, locations and lamp color with architect. ABBREVIATIONS _ IIncandescent S Surface mounted F Fluorescent R Recessed MH Metel Halide W Watts or Wall LED Light EmittinDiode THE INDICATED LIGHTING DESIGN MEETS THE REQUIREMENTS OF SECTION 4.17 OF THE ZONING ORDINANCE. INTEC Group, Inc. 214 W. TREMONT AVENUE S U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net CONSULTANT 011� DWYER ENGINEERING www.dwyer.com 552 Fort Evans RD STE 200 Leesburg, VA 20176 PH: 703-777-5988 PROJECT r-1 d1 N N Q UJ O J �I LU =z V- � U Ce WLLi LU F' Q Z w U J Q � _ O 1-H 00 STAMP DRAWING LOG SHEET INFORMATION DATE OF DRAWING: 07.07.17 DRAWN BY: BSD 30B NUMBER: 117101 LIGHTING & PHOTOMETRIC PLAN PH001 1 I 1 T 1 1 1 T I 1 I I 1 T � 1 I 1 1 I 1 1 1 1 1 _ -- 4..6 a+ +-1.2 �41 . a 1 1 4.8 4.8 +a I+ 4.8 -r^ 4.9 a .)� a 2A +'1.5 +2.0 +�_ 3.5 4.?. 1 4.7 +3a . �a '5.2 5 2 +5.4 s 5.4 .a > ' +6.0 + � 7 +a 5. +5.9 _ ''.6 a ! +1 +5.5 i 3 5.2 a 5.1 +4.9 a +5-i-- �§:rJ=-z�1 4 a 4 7 61 + 4 6 4.4 a 3,r s.4 a 12 8 , .7 4.4 , 4.9 5.8 SA 5.8 ,, '�0-- 4.9 5.0 c. 5.0 4.9 5.0 , 8 4.9 4+0 1 +1.5 e�,''. -- I 3.�b-4-1 .a 1 =r,- -- s-.3 - �- - � - ,:fY-' 1 +-.'1-$.�' -.4-- +44 - 44- - ,"- + .. I - A.n-.. °..1 + .. f �"r.7- -�t� - -4:'- +44 -+ . +2.' I 7. -cE.� +3.'- c;,6 +0.0 '.5 2.9 3.5 40 4.5 X4.7 4.9 4.9 4.6 3.3 24 2.3 3.7 3.6 4.2 3.9 3.6 2.3 1 1.6 1.1 2., 3.1 2.8 3.7 2.7 13.9 1.1 ZO 1 2.0 2.5 3.5 3.6 3.3 2.9 2.6 2.1 is 1.2 +- +0.6 1 +�.0 1 +2.L• +3.0 +3.9 +4.1 +4.2 +3.7 +3.3 +3.2 1 '318 +2.8 +2.3 +2.6 +3.3 +2.7 +2.5 1 +2.4 +1.8 +2-� 1 +3.0 +2.1 +2.0 +2.3 I +1.8 1 +1.81 +1.6 +2.4 +2.4 +2.8 +2.7 +2.5 +2.1 I +i.3 +0.9 I (~3S 1 I 1+2.7 I I 12.8 1 I 11.7 I LIGHTING & PHOTOMTRIC PLAN H00 1/8" - 1'-0" LIGHTING FIXTURE SCHEDULE ID TYPE MFG MODEL LAMPLUMENS WATTS SIZE ll SERVES A LED LMhoni. VRR-LED-IL-FHL-120 1500 26 12'x 12"x 10' R Canopy Lighting NOTES 1) Coordinate voltage of fixture type Ain field to match voltage of existing calwpy fighting cirouR 2) Verify finishes, mounting heights, locations and lamp color with architect. ABBREVIATIONS _ IIncandescent S Surface mounted F Fluorescent R Recessed MH Metel Halide W Watts or Wall LED Light EmittinDiode THE INDICATED LIGHTING DESIGN MEETS THE REQUIREMENTS OF SECTION 4.17 OF THE ZONING ORDINANCE. INTEC Group, Inc. 214 W. TREMONT AVENUE S U I T E 3 0 1 CHARLOTTE, NC 28203 P: 704.372.7910 www.intecgroup.net CONSULTANT 011� DWYER ENGINEERING www.dwyer.com 552 Fort Evans RD STE 200 Leesburg, VA 20176 PH: 703-777-5988 PROJECT r-1 d1 N N Q UJ O J �I LU =z V- � U Ce WLLi LU F' Q Z w U J Q � _ O 1-H 00 STAMP DRAWING LOG SHEET INFORMATION DATE OF DRAWING: 07.07.17 DRAWN BY: BSD 30B NUMBER: 117101 LIGHTING & PHOTOMETRIC PLAN PH001