Loading...
HomeMy WebLinkAboutARB201700070 Checklist 2017-07-26HNM 7/26/17 F. Additional material 1 ® Sheet number, total number of sheets, date of the drawing, date and description of the latest revision, and contact information for the firm preparing the drawings in the title block on all drawings. 2 ® Provide labeled, color 8-'/i' x 11" photos of the site as seen from both directions on the Entrance Corridor. 3 ❑ Any additional material that will make the review more productive. Clarification of topography, visibility, utilities, landscaping, or other unique or unusual conditions are welcome. Application is complete Revised 6/10/10 — 1 Completeness Check COUNTY -WIDE CERTIFICATE OF APPROPRIATENESS Building Permits where the change is 50% or less of the altered elevation Project name: ARB2017-70 Ashley Furniture fagade renovation 1 ® Submittal packages must contain 2 collated & folded copies of all info unless otherwise stated. A. Written description of the proposal 10 Provide a general description of all proposed work. 2 b1 Explain how the proposal is compatible with the surrounding area and the Entrance Corridor. — Commented [HM1]: Not provided, but the renovation is consistent with previously approved renovations on other storefronts B. Site plan/Sketch plan showing the following (drawn to the scale of 1"=20', clearly legible): within the shopping center 1 ® Location of all proposed changes in relation to the Entrance Corridor street. 2 F❑1 If mechanical equipment or accessory structures are altered or added then identify those __- Commented [HM2]: N/A features, their locations, and screening that will eliminate visibility from the Entrance Corridor. 0. Landscape plan showing the following (drawn to the scale of 1"=20' clearly legible): — Commented [HM3]: N/A 1 ❑ Existing landscaping to be removed. Include the location, size, and species. 2 ❑ Proposed landscaping. 3 ❑ Landscape schedule indicating plant species with common and botanical names, plant quantity, size at planting, and symbol used. D. If new lighting is proposed or existing lighting will be modified, provide a lighting plan showing the following (drawn to the scale of 1 "=20' and clearly legible): 1 ® Location of all proposed building and site lighting. 20 Manufacturer's cut sheets with a diagram of the proposed fixture(s) sufficient to determine if it is a full cutoff fixture. Include cut sheets as a separate sheet of the site plan set. 3 ® Lighting schedule identifying all proposed light fixtures, poles and brackets. Identify illumination type, intensity, style, shielding, color, finish, and installation height. 4 ® Photometric plan addressing all fixtures and indicating that lighting meets the requirements of section 4.17 of the Zoning Ordinance. ILLF must equal 1.0.1 Commented [HM4]: Not given E. Appearance of the proposed building(s) 1 ® Architectural elevations of the proposed building(s). Elevations must be drawn to the scale of at least 1/8"=1'-0". Include existing condition and proposed changes. Include a building materials schedule and key. 2 ❑1 One set of all building material samples and colors. Commented [HMS]: Not provided, but materials schedule and 3 ® A floor plan adequate to show exterior walls, windows and doors. key on the architectural elevations suffice. F. Additional material 1 ® Sheet number, total number of sheets, date of the drawing, date and description of the latest revision, and contact information for the firm preparing the drawings in the title block on all drawings. 2 ® Provide labeled, color 8-'/i' x 11" photos of the site as seen from both directions on the Entrance Corridor. 3 ❑ Any additional material that will make the review more productive. Clarification of topography, visibility, utilities, landscaping, or other unique or unusual conditions are welcome. Application is complete Revised 6/10/10 — 1 ARB2017-70: Ashley Furniture facade renovation HNM 7/26/17 LIGHTING PLAN REVIEW CHECKLIST CHECKLIST ITEM NOTES Cut sheets Lumen level (3000 or more must be full cutoff) OK: lumens = 1596 Bulb/lamp location (must be totally within house to be full cutoff) OK: Holophane flat glass model = full cutoff Luminaire schedule ❑ Catalog # coordinated with cut sheets OK Fixture quantity/types coordinated with quantity/types on lighting plan Quantity not given on lighting schedule but 15 shown on lighting plan Pole height/mounting height (ARB) N/A: recessed lights Colors/finishes (ARB) OK: white casing will not be seen from EC Tilt (must be 0 for full cutoff) N/A: recessed lights Fixture locations Location conflicts with trees, utilities, etc. N/A: recessed lights ❑ Coordination with other site plan sheets N/A: recessed lights ❑ Shielding issues (freestanding signs, wall fixtures, etc.) N/A: recessed lights in ceiling of arcade Photometric plan ❑ Adjacent zoning N/A ❑ Property lines Footcandle (fc) value = 1.5 at the storefronts' boundaries ❑ Excessive spillover OK ❑ Excessive lighting levels (ARB) OK: highest value is 6 fc Maintenance factor = 1.0 Not given, but highest fc value = 6, well below ARB maximum of 20 fc ❑ Standard lighting notes: Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-halffootcandle. N/A: light emittance under 3,000 lumens ARB2017-70: Ashley Furniture fagade renovation HNM 7/26/17 COUNTY -WIDE CERTIFICATE OF APPROPRIATENESS Building pen -nits in which the proposed change occupies 50% or less of the altered elevation DESIGN CRITERIA Proportion Alteration must be in proportion with the existing OK: alterations are consistent with previously approved and elevation. recently completed fagade renovations to other storefronts Roof form Roof form must be consistent with the existing patterns OK: the change from a pitched roof broken by a pediment to a flat of scale and proportion of the roof form of the existing roof with a parapet is consistent with previously approved and building. recently completed facade renovations to other storefronts Materials Materials must be consistent with the existing patterns OK: all proposed materials will match existing; no vinyl proposed of scale and proportion of the existing materials. No new vinyl. Colors Colors must be coordinated with existing colors. OK: all proposed colors will match existing Planting Trees and shrubs may be required to integrate the N/A alteration into the building and site.