HomeMy WebLinkAboutSDP201700048 Review Comments Pre-application Plan 2017-08-18• C-TQ�. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Plan Review Project title: Floor Fashion — Pre -application Project file number: SDP201700048 Plan preparer: Meridian Planning Group, LLC [tmiller@meridianwbe.com] Owner or rep.: Ryder Enterprises, LLC Plan received date: 04 August 2017 Date of comments: 18 August 2017 Reviewers: Frank V. Pohl, PE This plan has been reviewed under sections of the Albemarle Code related to this application. The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review and responses. 1. Central Sewerage System - Applicant shall notify the board of supervisors of the proposed central sewerage system. Refer to Sec. 16-102 for notice requirements. 2. VDH permit may be required for the central sewerage system [16-105.13]. 3. A maintenance agreement for the central sewerage system will be recommended to the board of supervisors as a condition of approval, assuming all other requirements have been addressed [16-105 & 14-317]. 4. Provide estimated water usage calculations for all uses to confirm a Special Use Permit is not required, considering public water is not available. Water use by the WWTP, if any is required, shall be included in the calculations. [22.2.2.11 ] 5. A critical slopes waiver will be required [18-30.7]. 6. Private Street: a. A road plan will be required for review. The road plan may be able to be incorporated into the site development plan but this determination must still be made. b. Provide estimated traffic generation for uses to be served by the private street. c. Retaining wall locations may need to be adjusted to provide required sight lines [Design Standards Manual]. d. A minimum 24-ft drive lane is required for the entire length of the street e. A minimum 3-ft clear zone is required from the travel lane or from the back of curb. Retaining walls shall be relocated out of the clear zone. f. Perpendicular parking is typically not permitted on roads and shall be minimized. `Mirroring' the SWM facility/parking may be required, in addition to other measures to ensure safe and convenient access to the rear parcel. g. A private road maintenance agreement will be required [14-234.E, 14.235, 14- 317]. h. The private street may need Commission approval considering access to the rear lot would not be limited to the private street [14-232.B.2]. 7. VSMP permitting and the re -development VRRM spreadsheet will be required. Engineering Review Comments Page 2 of 2 Engineering plan review staff are available from 2-4 PM on Thursdays, should you require a meeting to discuss this review. County forms can be found on the county website forms center under engineering: hlt2://www.albemarle.ora/del2tforms.asp?department--cdengno File: I:\DEMCommunity Development\Engineering Division\Frank Pohl\Projects\SDP201700048-Floor Fashion