Loading...
HomeMy WebLinkAboutSDP201700019 Approval - County 2017-09-15COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 September 15, 2017 Chris Schooley Cds7c@eservices.virginia.edu RE: SDP2017-19 UVA Indoor Golf — Initial Site Development Plan Mr. Schooley: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final site plan for all or a portion of the site within one (1) year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final site plan. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. Approval of all easements for facilities for stormwater management and drainage control. Submittal of a landscaping plan and tree conservation checklist with areas for tree preservation identified to demonstrate that conditions from SP2017-09 can be met. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. A fee of $1,613. Please submit 8 copies of the final plans to the Community Development Department. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies (for ACSA, please submit 3 copies of construction plans directly to them, as stated in their comments). Once you receive the first set of comments on the final site plan, please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members: Albemarle County Planning Services (Planner) - 2 copies [Rachel Falkenstein, rfalkenstein@albemarle.org] Albemarle County Engineering Services - 1 copy [Matt Wentland, mwentland@albemarle.org] Albemarle County Information Services (E911)- 1 copy [Andy Slack, aslack@albemarle.org] Albemarle County Planning Services (ARB)- 1 copy [Heather McMahon, hmcmahon@albemarle.org] Albemarle County Building Inspections —1 copy [Michael Dillinger, jschlothauer@albemarle.org] Albemarle County Department of Fire Rescue- 1 copy [Robbie Gilmer, rgilmer@albemarle.org] Albemarle County Service Authority — 3 copies submitted directly to ACSA [Alex Morrison, amorrison@serviceauthority.org] Virginia Department of Transportation- 1 copy [Adam Moore Adam.Moore@VDOT.virginia.gov] If you have any questions about these conditions or the submittal requirements please feel free to contact me at (434) 296-5832 x3272, rfalkenstein@albemarle.org. Sincerely, V U wb�� Rachel Falkenstein Senior Planner r� 'AL � IRGS?at� County of Albemarle Department of Community Development Memorandum To: Mr. Chris Schooley (cds7c@eservices.virginia.edu) From: Rachel Falkenstein, AICP — Senior Planner Division: Planning Services Date: September 13, 2017 Subject: SDP-2017-00019 UVa Indoor Golf Practice Facility— Initial Site Plan The Planner for the Planning Services Division of the Albemarle County Department of Community Development (CDD) will recommend approve of the plan referred to above when the following items have been satisfactorily addressed. The following comments are those that have been identified at this time; additional comments or conditions may be added or eliminated based on further review. [Each comment is preceded by the applicable reference to the Albemarle County Code.] 1. [SP2017-09] Demonstrate compliance with approved SP conditions and concept plan, specifically: a. Provide earthen berms around parking areas as shown on concept plan. Show berms on all applicable plan sheets and provide detail. b. How do pedestrians access facility? Plans do not contain any "crushed stone walkway' or similar sidewalk or pathway element, as shown on concept plan. 2. [SP2017-09] Update condition notes on sheet C0.01 per BOS action on 9/13/17 3. [4.12.15(g)] Curb and gutter is required at the edges of parking areas and along travelways. Please revise. 4. [4.12.16(c)] FYI —the minimum parking space width is 9' when 24' aisle width is provided. 5. [4.12.16(c)(1)] The minimum travel way width for 2-way traffic is 20'. Please revise. 6. [4.12.2] Design requirements of sections 4.12.15 & 4.12.16 may be modified or waived by the Zoning Administrator, after consultation with the County Engineer. 7. [32.5.2(b)] Include a description of the proposed use(s) and improvements, including (but not limited to) a description of the proposed improvements within the extensive linear areas of disturbance. 8. [32.5.2(d)] Tree Protection practices are proposed for two trees (55" ash and 40" cedar) adjacent to the parking area. The dripline of the trees is shown inconsistently across plan sheets and on some sheets it appears disturbance will occur within the dripline of these trees. Please review and address this issue by revising the grading to ensure no grading/disturbance occurs within the tree driplines. Reducing width of parking spaces to 9' might help pull grading away from tree driplines. 9. [32.5.2f] Include the location (and name, as may be applicable) of all on site water features. 10. [32.5.2(n)] WPO sheets (stormwater and E&S) should be removed from site plan set. 11. [32.5.2(n)] Only permanent features should be shown on site plan sheets. If staging/stockpile area is intended to be a permanent site improvement, label this on all applicable sheets; otherwise, the fencing and hatched rectangle area can be removed from the site plan sheets. Tree protective fencing should be shown on landscaping sheet; other temporary fencing need not be shown on site plan sheets. 12. [32.5.2n] Confirm that there are no proposed loading or service areas, or revise to indicate the location of proposed loading or service areas. 13. [32.5.2p] Revise the Planting Calculations and/or Planting Schedule to specify the canopy coverage of each species of proposed landscaping in accordance with the Albemarle County Recommended Plants List. 14. [32.6.2] Provide cut sheets for proposed lights (full cutoff lights required), list mounting heights, show light fixtures on all site plan and landscape sheets. 15. [32.7.9.4] Show existing/proposed contours, limits of clearing, location and type of tree protective fencing and landscape plan. Please contact Rachel Falkenstein at the Department of Community Development at (434)-296-5832 ext. 3272 or rfalkenstein@albemarle.org for further information. Review Comments for SDP201700019 Initial Site Plan Project Name: UA Foundation Golf Facility - Initial Date Completed: Friday, September 08. 2017 Department/Division/Agency: Review Status: Reviewer: David James CDD Engineering Requested Changes 1- Provide required parking information, and amount provided- - Provide curb and gutter in parking areas and along travelways [184-12-15]- 3- Show sight distance line- Ensure that 100-foot (min) site distance is maintained at intersection and parking cimLllation [18- 4-12-15]- 4- Min- isle width of 20' for 10' wide parking spaces; for 9' wide 4' width aisles- 5- Extend curb bumpout to end of parking space- 6- Bumper blocks only needed in front of sidewalk (if proposed) and not needed where curb and gutter used- 7- The minimum travelway width for 2-way access aisles is 0-feet; for 1-way 12-feet- 14' shown- 20' shown with emergency access turfdoes not meet County requirements Page: County of Albemarle Printed On: 10911 T2017 Review Comments for SDP201700019 11nitial Site Plan Project Name: UA Foundation Golf Facility - Initial Date Completed: Thursday, September 07, 20 77 Department1DivisionfAgency: Review Sys: Reviewer: Heather McMahon LJ CBBARB Requested Changes The following changes are requested to meet ARB standards and criteria as the subject property falls within the EC overlay district: 1. The following note should be added to the site and architectural plans: "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated_" 2_ The landscape plan must include the standard plant health note: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited_" 3_ A revised lighting plan in which: a_ CLIt sheets for all lighting fixtures are provided on a separate sheet in the site plan set_ b_ Mounting heights of light poles are given in which the base heights are included and specified_ c_ The color of the lighting fixtures are noted_ Bronze or black are approvable in the EC overlay district_ d_ The standard lighting note is included on the plan: "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads_ The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle_" e_ The lighting and landscape plans are coordinated to ensure that there are no potential siting conflicts with lighting fixture placement and proposed and extant landscaping and utilities_ There is a potential conflict with a proposed Red Maple and a light fixture on the southwest corner of the proposed parking area_ f_ The size and shape of the proposed parking area is consistent with other site plan drawings_ Page: County of Albemarle Printed On: 10911512017 Review Comments for SDP201700019 11nitial Site Plan Project Name: UA Foundation Golf Facility - Initial Date Completed: Monday, September 11, 2017 Department1DivisionfAgency: Review Sys: Reviewer: Robbie Gilmer ­3 Fire Rescue I Requested Changes Based on plans dated 81 3117_ 1_ Fire flow test requires 1500 gpm minimums, due to the decreased flo}r; on the Q20 a fire pLimp maybe required- _ Increase the turning radius for the emergency turn arOLInd at the 1 story brick barn 3_ Relocate the FDD to the Address side of the structure and within 100' of a fire hydrant 4_ Please show the specs for the Stalite Structural soil_ The soil shall support 80.000 Ibs for fire apparatus_ Page: County of Albemarle Printed On: 10911 T2017 Review Comments for SDP201700019 11nitial Site Plan Project Name: UA Foundation Golf Facility - Initial Date Completed: Friday, May 12, 2017 Department1DivisionfAgency: Review Sys: Reviewer: Alexander Morrison ACSA See Recommendations • Water and Sewer Construction Plan Review by the ACSA will be required at the final site plan stage_ Submit 3 copies of the plan along with water and sewer data sheets to the ACSA, Attn: Michael Vieira, PE, to start the review_ • A hydraulic report will be required prior to final site plan approval to show that the proposed water main replacement will allow the applicant to achieve the required fire flow on site_ • RA review and approval of the proposed sewer connection is required prior to final site plan approval_ Page: County of Albemarle Printed On: 10911512017 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper Virginia 22701 Charles A. Kilpatrick, P.E. Commissioner April 27, 2017 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Rachel Falkenstein Re: UVA Foundation Golf Facility — Initial Site Plan SDP-2017-00019 Review #1 Dear Ms. Falkenstein: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Bartzen & Ball, dated 31 March 2017, and finds it to be generally acceptable. However, note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. If further information is desired, please contact Justin Deel at 434-422-9894. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING