HomeMy WebLinkAboutWPO201700028 Review Comments Grading Plan 2017-10-26
County of Albemarle
Department of Community Development
Memorandum
To: Scott Collins
From: Matt Wentland
Date: 12 May 2017
(Rev. 1) 25 October 2017
Subject: Hyland Park Final Grading Plan (SUB201700034/WPO201700028)
Scott,
The final grading plan for Hyland Park has been reviewed by Engineering. The following comments will
need to be addressed before approval:
1. Show the grading of the trails and include the Class A Type 1 trail standards on the plans.
(Proffer 2A) (Rev. 1) Comment partially addressed. Include the trail standards on
the plans (or let me know if I missed it).
2. Show the proposed Delphi Lane connection on the plans. (Proffer 2A) (Rev. 1) Comment
partially addressed. Include any ESC and SWM measures for the connection and it
will also need to match the road plans. Any off-site easements will need to be
acquired before approval.
3. Show the relocation and grading of the existing driveway being disturbed by the proposed
Delphi Lane connection. (Proffer 2A) (Rev. 1) Comment partially addressed, see
above.
4. Provide a landscape plan satisfying Proffer 4 as part of the final grading plan. (Proffer 4,
18.31.7.9.4) (Rev. 1) Comment partially addressed. Lots 13 and 23 have four trees
each (Lots 14 and 20 have six). Zoning has also determined that the open space lots
count as lots that will need to have trees planted or retained. If the trees are to be
retained, a conservation plan will be needed. Include the abbreviations for the trees
on the tables and break the size column into caliper and height.
Revision 1 Comments
1. The areas of preserved slopes shown on and behind Lot 9 will need to be field verified (or the
building lot and retaining wall revised) prior to approval. The County Engineer has determined
that certification from a surveyor will be required when preserved slopes in the GIS overlay are
shown to be less than 25% (this will apply to future plans as well). Please contact Frank Pohl if
further guidance is needed.
File: WPO201700028 Hyland Park grading plan Comments rev1 10-25-17.doc