Loading...
HomeMy WebLinkAboutSDP201700061 Plan - Submittal (First) Major Amendment, Final Site Plan 2017-10-23VICINITY MAP: 1" = 500' N ' a4t4 / % , ki t Charl,-AW, Y. klumphriw C- GENERAL CONSTRUCTION NOTES Cg►�li ALBEMARLE COUNTY, VIRGINIA MAJOR SITE PLAN AMENDMENT (SDP 2017-OOOXX) OCTOBER 23,2017 FINAL APPROVAL: PERFORMANCE AND QUALITATIVE NOTES AND STANDARDS ALBEMARLE COUNTY SERVICE AUTHORITY CONSTRUCTION NOTES 1. ALL SITE WORK AND ALL IMPROVEMENTS SHOWN ON THESE PLANS ARE REQUIRED TO BE PERFORMED AND / OR INSTALLED. UNLESS SPECIFICALLY ITEMIZED AS "NOT INCLUDED IN 1. WORK SHALL BE SUBJECT TO INSPECTION BY THE ALBEMARLE COUNTY SERVICE AUTHORITY INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER TRIPS CONTRACT" IN THE OWNER / CONTRACTOR AGREEMENT, THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING AND / OR INSTALLING ALL SITE WORK AND IMPROVEMENTS SHOWN ON TAX MAP / PARCEL #: SERVICE AUTHORITY OFFICIALS AT THE START OF THE WORK. PROPERTY ADDRESS: THESE DRAWINGS, INCLUDING ANCILLARY EFFORTS AND WORK NORMALLY ASSOCIATED WITH SPECIFIED IMPROVEMENTS. PROPERTY SIZE: 0.627 ACRES ZONING: C1 COMMERCIAL 2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN, ARE ONLY APPROXIMATELY 2. CALL MISS UTILITY (1-800-552-7001) PRIOR TO ANY LAND DISTURBING ACTIVITY. UTILITIES SHOWN ON THESE PLANS ARE REPRESENTATIONS OF DATA MADE AVAILABLE TO THE ENGINEER PROPOSED USE: CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. DRINKING WATER WATERSHED: FROM VARIOUS SOURCES AND HAVE NOT BEEN FIELD CONFIRMED. EXPLORATORY EXCAVATIONS MAY BE NECESSARY TO CONFIRM THE EXISTENCE OR NON-EXISTENCE OF CERTAIN DAM INUNDATION ZONE: NO AIRPORT IMPACT AREA: UNDERGROUND FEATURES. 3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS AS ADOPTED BY THE TOTAL # OF UNITS / DENSITY: N/A DENSITY BONUS FACTORS: ALBEMARLE COUNTY SERVICE AUTHORITY. 3. THE CONTRACTOR SHALL COORDINATE WITH ALL LOCAL AUTHORITIES PRIOR TO COMMENCING THE WORK AND SCHEDULE / ATTEND ALL REQUIRED PRE -CONSTRUCTION MEETINGS. THE SPECIAL EXCEPTIONS: NONE CONTRACTOR SHALL CONFIRM THAT ALL BONDS HAVE BEEN POSTED AND PULL ALL PERMITS. THE CONTRACTOR SHALL MAINTAIN THE PERMITS AND AN APPROVED SET OF THESE 4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. SEE PROJECT DATA FOR MORE DETAILED DESCRIPTION. WORKING DRAWINGS AND PROJECT SPECIFICATIONS ON-SITE AT ALL TIMES. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING "MISS UTILITY" (1-800-552-7001). 4. THE CONTRACTOR SHALL COORDINATE WITH THE OTHER TRADES ON-SITE. 6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF 3 FEET OF COVER MEASURED FROM THE TOP OF THE PIPE, OVER THE CENTERLINE OF THE PIPE. THIS INCLUDES ALL FIRE 5. UNEXPECTED SITE CONDITIONS MAY ARISE DURING CONSTRUCTION THAT REQUIRE A DEVIATION FROM THESE PLANS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. CONDITIONS THAT CONFLICT WITH THE PROPER EXECUTION OF THESE PLANS. THE ENGINEER SHALL DETERMINE THE NATURE AND DEGREE OF CHANGES NECESSARY, AND THE CONTRACTOR SHALL PROVIDE A COST FOR SAID CHANGES. NO CHANGES ARE TO BE MADE WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. 7. ALL WATER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 6. CONTACT ENGINEER IF THERE ARE QUESTIONS REGARDING THE LAYOUT OF THE WORK. BUILDING INFORMATION REFLECTED ON THESE DRAWINGS MAY NOT REPRESENT FINAL 8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. ARCHITECTURAL DIMENSIONS. PRIOR TO STAKEOUT OF ANY STRUCTURES, SURVEYOR AND / OR CONTRACTOR SHALL OBTAIN FINAL ARCHITECTURAL DRAWINGS AND CONSULT WITH ENGINEER REGARDING EXACT PLACEMENT OF BUILDINGS ON SITE. 9. AS -BUILT CONSTRUCTION DATA SHALL BE MAINTAINED BY THE CONTRACTOR IN THE FIELD. A MARKUP SET OF PLANS SHALL BE PROVIDED TO THE OWNER OR HIS REPRESENTATIVE TO SERVE AS THE BASIS FOR THE FINAL AS -BUILT PLANS. THE DATA RECORDED SHALL BE IN ACCORDANCE WITH THE CITY/COUNTY REQUIREMENTS AS SPECIFIED LATEST EDITION 7. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS AND FEATURES REPRESENTED ON I THESE PLANS TO THE BEST OF HIS / HER ABILITY. THE CONTRACTOR SHALL ALSO VERIFY, BY CHECKLIST. STAKEOUT, THE RELATIONSHIP OF ALL MAJOR SITE IMPROVEMENTS TO EXISTING SITE CONDITIONS ,AND FEATURES AND NOTIFY ENGINEER OF ANY DISCREPANCIES, ERRORS AND OMISSIONS BEFORE PROCEEDING WITH THE WORK. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES FOR SITE PLANS 8. THE CONTRACTOR SHALL BE HELD SOLELY RESPONSIBLE FOR SITE CONDITIONS, THE SAFETY OF HIS / HER WORKERS AND THOSE ASSISTING HIM / HER WITH SUPPLYING OR EXECUTING THE 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE WORK, AND THE SECURITY OF PROPERTY HE / SHE IS STORING ON-SITE. THE CONTRACTOR IS NOT LIABLE FOR THE SAFETY OF THOSE WITHIN THE BUILDINGS OR WORKING ON THE BUILDINGS, VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY NOR IS HE / SHE RESPONSIBLE FOR SECURING THE PROPERTY OF THE BUILDING CONTRACTOR OR THEIR ASSOCIATED TRADES. HOWEVER, CONTRACTOR IS REQUIRED TO MAINTAIN A DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. CLEAN, ORGANIZED AND SAFE SITE, AND IS THE FINAL AUTHORITY AS TO) HE LOCATION, PLACEMENT OR STORAGE OF ANY AND ALL MATERIALS, EQUIPMENT, VEHICLES AND TEMPORARY STRUCTURES USED DURING CONSTRUCTION. NEITHER THE OWNER NOR ENGINEER SHALL BE HELD RESPONSIBLE FOR THEFT, DAMAGE OR INJURY ON-SITE DURING CONSTRUCTION UNLESS IT 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. IS DUE TO TO THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO 9. THE CONTRACTOR SHALL DETERMINE THE LIMITS OF CONSTRUCTION AND MARK THEM CLEARLY PRIOR TO COMMENCING GRADING OF THE SITE.. ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 10. DURING THE INSTALLATION OF UTILITIES TO SUPPORT THE PROJECT, THE CONTRACTOR SHALL MAINTAIN SERVICE TO NEIGHBORING PROPERTIES. DAMAGE TO LINES OR INTERRUPTIONS OF 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. SERVICE SHALL BE IMMEDIATELY REPORTED TO THE SERVICE PROVIDER AND ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH REPAIR AND RESTORATION OF SERVICE. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 11. ALL EXISTING IMPROVEMENTS ADJACENT TO THE PROPERTY, SUCH AS ROADWAYS, SHALL BE PROTECTED FROM DAMAGE DUE TO THE EXECUTION OF THE WORK. ALL REPAIR MADE 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN NECESSARY BY THE CONTRACTOR OR THOSE ASSISTING HIM / HER IN THE EXECUTION OF THE WORK SHALL BE BORNE BY THE CONTRACTOR. ORDER TO STABILIZE A DRAINAGE CHANNEL. 12. USE OF EXPLOSIVES IS EXPRESSLY PROHIBITED UNLESS STATED OTHERWISE, IF PERMITTED, THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ENGINEER PRIOR TO 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. STORING OR USING EXPLOSIVES ON-SITE. ALL OTHERS SHARING THE SITE FOR CONSTRUCTION PURPOSES SHALL ALSO BE NOTIRED. USE OF EXPLOSIVES SHALL BE CAREFULLY COORDINATED WITH ALL OTHERS SHARING THE SITE AS WELL AS VDOT AND ADJACENT OWNERS. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 13. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). DEPARTMENT OF TRANSPORTATION (VDOT). ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES FOR STREETS 14. CONTRACTOR SHALL COORDINATE TRAFFIC CONTROL MEASURES WITH VDOT INSPECTORS PRIOR TO OR AS PART OF THE REQUIRED PRE -CONSTRUCTION CONFERENCE. 1. CONSTRUCTION INSPECTION OF ALL PROPOSED ROADS WITHIN THE DEVELOPMENT WILL BE MADE BY THE COUNTY. THE CONTRACTOR MUST NOTIFY THE DEPARTMENT 15. ALL UNSUITABLE SOIL MATERIAL SHALL BE STOCKPILED AND ITS DISPOSITION DETERMINED BY THE OWNER WHILE THE EARTHWORK ASPECT OF THE SITE WORK IS STILL UNDERWAY. OF COMMUNITY DEVELOPMENT (296-5832) 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION. 16. ALL SPRINGS SHALL BE CAPPED AND PIPED TO THE NEAREST DRAINAGEWAY OR DIRECTED TO A STORM SEWERAGE STRUCTURE. 2. UPON COMPLETION OF FINE GRADING AND PREPARATION OF THE ROADBED SUBGRADE, THE CONTRACTOR SHALL HAVE CBR TESTS PERFORMED ON THE SUBGRADE SOIL. THREE (3) COPIES OF THE TEST RESULTS SHALL BE SUBMITTED TO THE COUNTY. IF A SUBGRADE SOIL CBR OF 10 OR GREATER IS NOT OBTAINABLE, A REVISED 17. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND PERIMETER MEASURES SHALL BE INSTALLED PAVEMENT DESIGN SHALL BE MADE BY THE DESIGN ENGINEER AND SUBMITTED WITH THE TEST RESULTS FOR APPROVAL. PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. THE CONTRACTOR SHALL NOT BE RELEASED FROM RESPONSIBILITY FOR STABILIZATION OF THE PROPERTY UNTIL THE LOCAL AUTHORITY OR AGENT ISSUES FINAL APPROVAL AND AUTHORIZES DECOMMISIONING OF EROSION CONTROL MEASURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR POSTING THE 3. SURFACE DRAINAGE AND PIPE DISCHARGE MUST BE RETAINED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN EASEMENTS PRIOR TO ACCEPTANCE BY THE COUNTY. ALL EROSION CONTROL BOND. DRAINAGE OUTFALL EASEMENTS ARE TO BE EXTENDED TO A BOUNDARY LINE OR A NATURAL WATERCOURSE. 18. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. THE MAXIMUM ALLOWABLE SLOPE IS 2:1(HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, 4. GUARDRAIL LOCATIONS ARE APPROXIMATE. EXACT LENGTH, LOCATION AND APPROPRIATE END TREATMENTS WILL BE FIELD VERIFIED AT THE TIME OF CONSTRUCTION. LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. ALL SLOPES 3:1 AND GREATER SHALL BE MATTED WITH VDOT EC -2 SLOPE STABILIZATION MAT. ADDITIONAL GUARDRAIL MAY BE REQUIRED AT LOCATIONS NOT SHOWN WHEN, IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY. WHEN GUARDRAIL IS REQUIRED, IT SHALL BE INSTALLED FOUR (4) FEET OFFSET FROM THE EDGE OF PAVEMENT TO THE FACE OF GUARDRAIL, AND ROADWAY SHOULDER 19. PAVED, RIP -RAP OR STABILIZATION MAT -LINED DITCHES MAY BE REQUIRED WHEN, IN THE OPINION I OF THE COUNTY AGENT, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE WIDTHS SHALL BE INCREASED TO SEVEN (7) FEET. CHANNEL. 5. WHERE URBAN CROSS SECTIONS ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT CG -9(A, B OR C). 20. ALL PAVING AND DRAINAGE -RELATED MATERIALS AND CONSTRUCTION SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. ALL MATERIALS TO BE USED IN STABILIZATION SHALL ALSO BE APPROVED BY ENGINEER. 6. WHERE RURAL CROSS SECTIONS ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT STANDARD PE -1. 21. ALL CURBING SHALL BE VDOT STANDARD CG -2, CG -6, CG -3, OR CG -7 AS NOTED ON THE PLANS. 7. COMPLIANCE WITH THE MINIMUM PAVEMENT WIDTH, SHOULDER WIDTH AND DITCH SECTIONS, AS SHOWN ON THE TYPICAL PAVEMENT SECTION DETAIL, SHALL BE STRICTLY ADHERED TO. 22. ALL PERPENDICULAR PARKING SPACES ARE TO BE 9'x 18' UNLESS OTHERWISE SPECIFIED. PARKING STALLS MAY BE REDUCED TO 16' WHERE A 2' OVERHANG IS POSSIBLE. 8. ROAD PLAN APPROVAL FOR SUBDIVISIONS IS SUBJECT TO FINAL SUBDIVISION PLAT VALIDATION. SHOULD THE FINAL PLAT FOR THIS PROJECT EXPIRE PRIOR TO SIGNING 23. ALL OFF-SITE PARALLEL PARKING SPACES TO BE 9'x 20' WITH A 20' MINIMUM AISLE WIDTH UNLESS OTHERWISE SPECIFIED. AND RECORDATION, THEN APPROVAL OF THESE PLANS SHALL BE NULL AND VOID. 24. ALL HANDICAP PARKING SPACES SHALL BE INDENTIFIED VIA THE USE OF SIGNS AND PAINT SYMBOLS. THEY ARE TO BE 8'X 18' AND ADJACENT TO A SX 18' PAINT -OUT AISLE OR A 8' X 18' 9. ALL SIGNS OR OTHER REGULATORY DEVICES SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES AND THE ALBEMARLE COUNTY PAINT -OUT AISLE IN THE CASE OF VAN ACCESSIBLE SPACES SHALL ROAD NAMING AND PROPERTY NUMBERING ORDINANCE AND MANUAL. 25. LOADING SPACES TO BE 12'x 25WITH A 24' MINIMUM AISLE WIDTH UNLESS OTHERWISE SPECIFIED. 10. TRAFFIC CONTROL OR OTHER REGULATORY SIGNS OR BARRICADES SHALL BE INSTALLED BY THE DEVELOPER OR CONTRACTOR WHEN, IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, THEY ARE DEEMED NECESSARY IN ORDER TO PROVIDE SAFE AND CONVENIENT ACCESS. 26. SAFETY RAILING TO BE PROVIDED FOR ALL WALLS HIGHER THAN 30". 11. THE SPEED LIMITS TO BE POSTED ON SPEED LIMIT SIGNS ARE 5 MPH BELOW THE DESIGN SPEED, OR AS DETERMINED BY VDOT FOR PUBLIC ROADS. 27. LOADING AND DUMPSTER AREAS SHALL BE ACCESSIBLE AT ALL TIMES AND ARE NOT TO BE LOCATED BEHIND ANY PARKING SPACES. 12. VDOT STANDARD CD -1 OR CD -2 CROSS -DRAINS TO BE INSTALLED UNDER THE SUBBASE MATERIAL AT ALL CUT AND FILL TRANSITIONS AND GRADE SAG POINTS AS SHOWN 28. UNLESS OTHERWISE SPECIFIED, ALL TWO-WAY TRAVELWAYS IN PARKING LOTS SHALL BE 24' WIDE. ONE-WAY TRAVELWAYS SHA1. BE 12' WIDE. ON THE ROAD PROFILES. 29. PARKING AREAS ARE NOT TO EXCEED 5% GRADE IN ANY DIRECTION. HANDICAPPED PARKING AREAS ARE NOT TO EXCEED 2% IN ANY DIRECTION. 13. A VIDEO CAMERA INSPECTION IS REQUIRED FOR ALL STORM SEWERS AND CULVERTS THAT ARE DEEMED INACCESSIBLE TO VDOT OR COUNTY INSPECTIONS. THE VIDEO INSPECTION SHALL BE CONDUCTED IN ACCORDANCE WITH VDOT'S VIDEO CAMERA INSPECTION PROCEDURE AND WITH A VDOT OR COUNTY INSPECTOR PRESENT, 30. DUMPSTER PADS TO BE MINIMUM 10' x 10'. AN ADDITIONAL 8' IS REQUIRED IN FRONT FOR WHEEL BEARING, RWSA CONSTRUCTION NOTES: SEE SHEET 2 31. SIDEWALKS TO BE A MINIMUM WIDTH OF 5, EXCLUDING CURB, CONSTRUCTED OF 4" 3000 PSI CONCRETE SURFACE, 4" 21-A STONE BASE, WITH UNDERDRAINS (UD -4, ETC. IF REQUIRED) PER VDOT STANDARDS. STANDARDS AND SPECIFICATIONS 32. UNLESS OTHERWISE SPECIFIED, ALL STORM SEWERAGE SHALL BE INSTALLED IN ACCORDANCE WITH VDOT STANDARDS AND SPECIFICATIONS. ALL REINFORCED CONCRETE PIPE SHALL BE CLASS 3. ALL HDPE PIPE SHALL BE ADS N-12 OR EQUAL W/ VDOT STANDARD PB -1 BEDDING. 1. VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.) ROAD AND BRIDGE SPECIFICATIONS, DATED 2007. 33. ALL PVC CONDUIT SHALL BE SCHEDULE 40. 2. VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.) ROAD AND BRIDGE STANDARDS, DATED 2008. 3. VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.) WORK AREA PROTECTION MANUAL, DATED 2011. 34. UNLESS OTHERWISE SPECIFIED, ALL WATERLINE IS TO BE CLASS 52 D.I.P .ALL WATER SERVICE LATERAL TO BE TYPE' K' COPPER TUBING. 4. VIRGINIA DEPARTMENT OF CONSERVATION AND RECREATION, DIVISION OF SOIL AND WATER CONSERVATION, VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, THIRD 35. ALL SANITARY SEWER LATERALS TO BE SDR -35 PVC AS A MINIMUM EDITION, 1992. 36. GRADING TOLERANCES OF FINISHED SURFACE: EARTHWORK SHALL CONFORM TO THE LINES, GRADES, AND TYPICAL SECTIONS SHOWN ON THE PLANS. CHANGES IN GRADE 5. INSTITUTE OF TRANSPORTATION ENGINEERS (ITE MANUAL), TRIP GENERATION, 8TH EDITION. SHALL BE ACCOMPLISHED BY SMOOTH CURVES WERE APPROPRIATE. 6. VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) STANDARDS, DATED 2009. 37. SHAPE SUBGRADE UNDER PAVEMENT AND CURB AND GUTTER TO WITHIN %2 INCH OF REQUIRED SUBGRADE ELEVATIONS. 7. ALBEMARLE COUNTY SERVICE AUTHORITY CONSTRUCTION SPECIFICATIONS REGULATING THE CONSTRUCTION AND EXPANSION OF THE WATER; AND SEWER SYSTEMS 38. FINISH PAVEMENT AND CURB AND GUTTER TO WITHIN %2 INCH OF REQUIRED FINISH ELEVATIONS. WITHIN THE COUNTY OF ALBEMARLE, VIRGINIA, DATED 2005. 8. INTERNATIONAL CODE COUNCIL AMERICAN NATIONAL STANDARD- ACCESSIBLE & USABLE BUILDINGS AND FACILITIES, DATED 2003. 39. SHAPE SUBGRADE UNDER SIDEWALKS TO WITHIN 0.10 FOOT OF REQUIRED SUBGRADE ELEVATIONS. 40. FINISH SIDEWALKS TO WITHIN 0.10 FOOT OF REQUIRED FINISH ELEVATIONS. SURVEYOR'S OR'S LEGEND UTILITIES LEGEND DEMOLITION LEGEND 41. FOR ALL OTHER AREAS, SUBGRADE AND FINISH ELEVATIONS SHALL BE WITHIN 0.10 FOOT OF REQUIRED CORRESPONDING ELEVATIONS. BH BORE HOLE GAS LINE G TBS TO BE SAVED BM BENCH MARK PHONE LINET TBR TO BE REMOVED 42. ANY TRANSPLANTED STOCK TO BE STOCKED -PILED ON SITE IN A LOCATION OUT OF CONSTRUCTION ACTIVITY AREAS. STOCK TO BE MULCHED IN AND ROUTINELY WATERED BY CO CLEAN OUT OVERHEAD ELECTRIC OEEX. EXISTING CONTRACTOR TO ENSURE SURVIVABILITY. ALL FUTURE LOCATIONS SHALL BE COORDINATED WITH LANDSCAPE ARCHITECT PRIOR TO PLANTING. PLANTING SHALL BE PERFORMED AT A DIP DUCTILE IRON PIPE SANITARY SEWER SUITABLE TIME IN ACCORDANCE WITH TYPICAL NURSERY PRACTICES. E SANITARY SEWER MANHOLE UNDERGROUND ELECTRIC UGE SITE ELEMENT TO BE REMOVED 43. ALL UTILITY CONDUITS SHALL BE LOCATED UNDER PAVING/HARDSCAPE SURFACES. CONTRACTOR TO VERIFY QUANTITIES AND SIZES WITH ALL SERVICE PROVIDERS PRIOR TO INSTALLATION IF MF IRON FOUND WATER LINE W MONUMENT FOUND EX. STORM DRAIN LINE AND ORDERING. ALL UTILITY PEDESTIALS SHALL BE GROUPED TOGETHER. CONTRACTOR TO INSTALL ALL CONDUITS WITH PULL -WIRES AND ENTEND CONDUITS PAST BACK OF CURB OR PF TREE TO BE REMOVED PIPE FOUND PROP. STORM DRAIN LINE SIDEWALK. TURN ALL CONDUITS UP AND CAP UNTIL UTILITY PROVIDER HAS INSTALLED GENERAL SERVICE. PKNS P -K NAIL SET \ '� 44. ALL STRUCTURAL FILL SHALL BE A MINIUM OF 95% COMPACTED BASED ON A STANDARD PROCTOR TEST. S WM SIGN UTILITY LINE TO BE REMOVED WATER METER WV WATER VALVE 45. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) STANDARDS. 240AK40 - 24" OAK W/ 40' CANOPY DIA. SITE DATA DEVELOPER: CLMB, LLC - 259 HYDRAULIC RIDGE ROAD, SUITE 203 CHARLOTTESVILLE, VIRGINIA 22903 BUILDING SQUARE FOOTAGE: CONTACT: BRAD SWISHER PROPERTY OWNER: CLMB, LLC - 259 HYDRAULIC RIDGE ROAD, SUITE 203 CHARLOTTESVILLE, VIRGINIA 22903 TRIPS CONTACT: BRAD SWISHER TAX MAP / PARCEL #: 61-24B PROPERTY ADDRESS: 2800 HYDRAULIC ROAD PROPERTY SIZE: 0.627 ACRES ZONING: C1 COMMERCIAL MAGISTERIAL: RIO COMPREHENSIVE PLAN: NEIGHBORHOOD 1 - PLACES 29 PROPOSED USE: DENTAL CLINIC DRINKING WATER WATERSHED: IVY CREEK/SOUTH RIVANNA RESERVOIR DAM INUNDATION ZONE: NO AIRPORT IMPACT AREA: YES ENTRANCE CORRIDOR: YES TOTAL # OF UNITS / DENSITY: N/A DENSITY BONUS FACTORS: NONE WAIVER / VARIANCE REQUESTS: NONE SPECIAL EXCEPTIONS: NONE SURVEY SOURCES: LINCOLN SURVEYING (434) 974-1417 THE IMAGERY AND/OR ORIGINAL DATA WAS OBTAINED ON MAY 9, 2017 DATUM: HORIZONTAL NAD -83 VIRGINIA SOUTH ZONE, VERTICAL NAVD-88. BENCHMARK: SURVEY NAIL AND FLASHING (T-171239623) IN THE MIDDLE OF EASTERN PARKING LOT, ELEV.590.04 MISS UTILITY TICKET NUMBER: A711801233-OOA LAND -USE BREAKDOWN: LAND -USE SF AO BUILDINGS: 5,8.50 0.134 21% PAVED ARLA: 13,892 0.319 51 PERVIOUS/OPEN AREA: 7,560 0.174. 287o TRIP GENERATION ESTIMATES: CODELAND USE GROSS SQUARE TOTAL SITE ACREAGE: 27,302 0.627 100% BUILDING SQUARE FOOTAGE: 5,065 SF TOTAL SETBACKS: 10' MINIMUM FRONT BUILDING SETBACK TRIPS 30' MAXIMUM FRONT BUILDING SETBACK 50' BUILDING SETBACK ADJACENT TO RESIDENTIAL 20' PARKING SETBACK ADJACENT TO RESIDENTIAL 20' BUFFER ZONE ADJACENT TO RESIDENTIAL MAX. HEIGHT OF STRUCTURE: 65BY CODE 36.13 40' EXISTING BUILDING 8.96 18' MAX. HEIGHT PROPOSED, 15' TYPICAL NUMBER OF EMPLOYEES: 10 ON A MAXIMUM SHIFT RECREATIONAL AREA: N/A LANDSCAPE REQUIREMENTS: SEE LANDSCAPE PLAN FOR CALCULATIONS PARKING REQUIREMENTS: 1 PARKING SPACE/175 SQUARE FOOT FOR DENTAL CLINIC: 5,065/175 = 29 REQ. SPACES PARKING PROVIDED: 33 PARKING SPACES PROVIDED TRIP GENERATION ESTIMATES: CODELAND USE GROSS SQUARE <AVG. WEEKDAY' WEEKDAY BEAK HOUR SATURDAY SUNDAY FOOTAGE TRIPS AM PM 720 MEDICAL -DENTAL OFFICE (TRIPS/ 1,000 SF) 5,065 36.13 3.6 .... 4.45 8.96 1.55 �1 X33 18 23 45 8 TRIPS GENERATED (50/50 SPLIT ON ENTER! WG/EXIT ING) 183 18 23 45 8 SITE NOTES: 1. THE PROJECT PROPOSES DEMOLISH iNG OF THE EXISTING RESTAURANT BUILDING AND CONSTRUCTION OF A NEW SINGLE STORY DENTAL CLINIC IN APPROXIMATELY THE SAME LOCATION. THE EXISTING PARKING LOT WILL BE PRESERVED AND RE -USED, 2. NO PORTION OF THE PROPERTY IS WITHIN THE 100 -YEAR FLOODPLAIN, 3, ANY SITE IDENTIFICATION OR AMENITY SIGNAGE DESIRED FOR THE DEVELOPMENT SHALL BE SUBMITTED AND FILED SEPARATELY BY THE OWNER. REVISIONS: APPROVALS: PLANNING/ZONING x w a t e r s t r e e t s w #0 landscape architecture I civil ergirleering 418E Main Strtsst 434.295.8177 s riaati s i!I , VA Y5 ��Lzx OP ' 7 I r'L Lie. No. 35326 ItW S".DNAL professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SWISHERSAPON project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions COVER SHEET sheet title C100 sheet number w a t e r s t r e e t ",-31L, U cll 0 iardscape architecture I civil engineering 0 E MairlSt-rest 434.295.8177 Charlottesville, VA 22 02 professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SAPON SWISHER DENTAL project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions EXISTING CONDTIONS sheet title C102 sheet number D P,,AE H - - --------- - I'RIM 591,86 01,JT 15" RCIP Cry' . Q N c', IHO nNo STONE SIGN — WALL TO MATCH STONE ON BUILDING 0 0 n +/'- 15-0, 110 NEXT UrQ� l�-T U R E S DMI -1 RI&A 685.48 I- 0 S A] 1e,x,J 4. jo 01 R/w MAINTAIN EXISTING PERIMETER OF PAVING, OVERLAY ASPHALT*, AND RE -STRIPE PARKING LOT *(MILL & REPAIR BASE WHERE APPLICABLE) DUMPSTER PAD & ENCLOSURE ASPHALT/ OVERhAY LIMITS 0 - -Z C__ 0 - 0 f 0 0 0 0 n +/'- 15-0, 110 NEXT UrQ� l�-T U R E S DMI -1 RI&A 685.48 I- 0 S A] 1e,x,J 4. jo 01 R/w MAINTAIN EXISTING PERIMETER OF PAVING, OVERLAY ASPHALT*, AND RE -STRIPE PARKING LOT *(MILL & REPAIR BASE WHERE APPLICABLE) DUMPSTER PAD & ENCLOSURE ASPHALT/ OVERhAY LIMITS I F 12BP2 I 0'_Oqro 0- -T 6'R P -1 I w,O C 2 0 A NA A P, 6 "s 91�0rj,20 E ril- E D'i 5 x, MAINTAIN EXISTING PERIMETER OF PAVING, R 5 :50 2X rp 4 K\V_ OVERLAY ASPHALT*, AND RE -STRIPE PARKING LOT *(MILL & REPAIR BASE WHERE APPLICABLE) PH AS'E I C, r . 1"') A REE" A 0MMCN T P 61 W 1I - 2-2, ETAL SAr� ' HIE/Vt VILLAGE Uj\�,IIT �11\JN 0C_RS ASS01--i'ATION F),13.44611 P, 345 D3. 865 P 438 D.B1542 P 360 PLAT D.B. 1489 A-�q PLAT D.B. 1131 P, 3419 D I LA -1 PLA T I P. D.B, 1026 P, 120 PLAT D, B 9911 Pp 3_56 P'LAT' 865 P. 447 PLAT D.B. 78'7 F-', 238 PLAT I F _-B F' E) w a t e r s t r e e�hyV.:y_F.. � s i i�.�� landscape architecture I civil engineering Z:) /1-18 E Main Street 434.295.8177 OiarloUesville, VA 229,02 professional seaI ALAN FRANKLIN project manager LUKE WALDRON project team DENTAL project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions LAYOUT PLAN sheet title 0 5' 101 20' C103 sheet number f I F 12BP2 I 0'_Oqro 0- -T 6'R P -1 I w,O C 2 0 A NA A P, 6 "s 91�0rj,20 E ril- E D'i 5 x, MAINTAIN EXISTING PERIMETER OF PAVING, R 5 :50 2X rp 4 K\V_ OVERLAY ASPHALT*, AND RE -STRIPE PARKING LOT *(MILL & REPAIR BASE WHERE APPLICABLE) PH AS'E I C, r . 1"') A REE" A 0MMCN T P 61 W 1I - 2-2, ETAL SAr� ' HIE/Vt VILLAGE Uj\�,IIT �11\JN 0C_RS ASS01--i'ATION F),13.44611 P, 345 D3. 865 P 438 D.B1542 P 360 PLAT D.B. 1489 A-�q PLAT D.B. 1131 P, 3419 D I LA -1 PLA T I P. D.B, 1026 P, 120 PLAT D, B 9911 Pp 3_56 P'LAT' 865 P. 447 PLAT D.B. 78'7 F-', 238 PLAT I F _-B F' E) w a t e r s t r e e�hyV.:y_F.. � s i i�.�� landscape architecture I civil engineering Z:) /1-18 E Main Street 434.295.8177 OiarloUesville, VA 229,02 professional seaI ALAN FRANKLIN project manager LUKE WALDRON project team DENTAL project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions LAYOUT PLAN sheet title 0 5' 101 20' C103 sheet number e—, - niqo nlqo SDMH RIM 591.86 OUT 15" RCP 587.86 /i 0 0 0 0 +/- 150' TO NEXT STRUCTURE SDMH RIM 585.48 IN 1,5" Prp .s8n 29 n1 IT 0 0 0 0 W'kHTMvn(­-%D R(IJAID% "S T AT E: R ILY FIE 14 5 5 \1, 60' R/W Z ------TO BE RE -USED MAINT I ISTIN41PERIMETA�R OF PAVING, KGL& M_ OVERLViASPHAL , AND R TRIPE PAR '(MILL & REPAIR BASE WHERE APPLICABLE) 59" DUMPSTER PAD & ENCLOSURE ___ z "'r FREE -4- 590.712 8'' DIP MN SSMH BOLTED SHUT RIM 595.88 ALL TREES TO REMAIN, IF HEALTHY A/1\ E C E MAINTAIN EXISTING PERIMETER OF PAVING, OVERLAY ASPHALT*, AND RE -STRIPE PARKING LOT '(MILL & REPAIR BASE WHERE APPLICABLE) If ,-a P H A U , M )N AREA txv/l Ci 'M P 6] W1--2-2, ETA L SACHEM VILLM-3,1E UNIT TREES TO REMAIN OWNERS ASSOCIA I DB� 4461 P'zA5 DB865 P� 438 D.B. P� 300 PLAT D.B. 1489 P. A3(, PL.A'l D,B. 1 131 P " 3 11,11 9 -11 -12 89 PLAT PLAT [DD 13, D,B. 1026 P, '20 PLAT D.B. OO ' - 13, 865 991 11 56 HP. ­ILAI D. PLA-r 1D.B. -787 P P. 44/ T 238 PLA D M% B 0- 00 MAINTAIN & RE -USE ASPHALT/, EXISTING SAN. OVERLAY SEWER LATERAL LIMITS, SSMH BOLTED SHUT RIM 590.62 'IV M_ M_� < ti SEWER EA1`S1EJP,/tE1NT D3. 548 P. 3196 EXISTING FIRE HYDRANT JF B F 11 GRATE 588.58 0 10' 20' 40' 10 w ate rst reets. ('�11 it landscape architecture I civil engineering 418 E Main Street 434.295-8177 Charlottesville, VA 12902 professional seal ALAN FRANKLIN project manager LUKE WALDRON project team 6�APON SWISHER 11 E N T, Pa, L project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions f GRADING & UTILIT\Y PLAN sheet title Qh4��=+ ni imh C104 aw LANDSCAPE C A L C U L A T1111.0 Road Frontage Requirement: I Large Shade Tree (3 1/2" cal.) per 40 Linear Feet of Road Frontage JHydraulic Road 103 Linear Feet Required: 3 Large Shade Trees Provided: 4 Large Shade Trees lWhitewood Road 190 Linear Feet Required: 4 Large Shade Trees Provided: No adequate room for planting Interior Parking Lot Trees . .... ............ ......................................... Requirement. J Large Shade Tree per 10 Parking Spaces IParking Spaces 33 Required: 4 Large Shade Trees Provided: 4 Large Shade Trees .Parking Lot --- ------ ---- �Requirement. 57of paved parking and vehicular ciruclation must be landscaped Area: - ---l --- --- -- 12,000 Square feet Required: 600 Square Feet Provided: 950 Square Feet Tree Canopy ............... ,.Requirement: 10% of Total Area ITotal Area :27,302 Gross Site Area 27,302 Rec. Areas O Pond Area 0 Wetland Area 0 .......... ...... .... .. Required: 2,730 Provided: 9,496 Tree Save 7,353 Canopy Bonus .. ........ 1,838 . ......... ..... .... ............ Proposed Trees :305 nHo OF nHo niqo nNo ------ 0 .PLANT SCHEDULE QTY. I SYMBOL IScientific Name ]Common Name Isize Ispacing I Root I Notes lioYear Canopy 'OVERALL SITE TREES AR Acer buergerianum 'Trident Maple 3.5" Cal, AS SHOW N B&B ..Single straight leader 25 :160 6 BN �Betula nigro'heritage' River Birch 3.5" Cal. AS SHOW N B&B Multi stem ---- - --------- - - - ----- ----- - ----------- - ------- -- ------ ------- - - - ------------------- - - ----- - -- --- --- - - ---- --- ----- ----------- ------ ------ - - ----- ------- - ------- - ----------------------- 6 HV Hamamelis virginano Common Witchhazel .2.5" Cal. AS SHOW N B&B Multi stem 120 ............ OVERALL SITE SHRUBS 122 IV Itea virginica 'Henry's Garnet' Sweetspire Ht, 0. C. CONT, 30 FG Fothergilla gardenii'blue mist' Dwarf Fothergilla .24" Ht. 0. C. CONT. 3 VR Viburnum x rhytidophylloides'alleghany' Lantanaphyllum Viburnum 18' Ht, 4'O.0 CONT. ;GROUNDCOVER 622 LM Lirop e muscari'big blue' Lily Turf 12" Ht. I O.C. PLUG ORNAMNETAL GRASSES 279 MC Muhlenbergia capilaris Pink Muhlygrass .2411 Ht, 2'0.C. CONT, 279 PV Panic um 'Cape Breeze' Switch Grass 24" Ht. 2' O.C. CONT. 0 / If (4) BETULA NIGRA 'HERITAGE' (z - EX. 6" BRADFORD PEAR (175 SF CANOPY) TO BE REMOVED EX. 10" LOCUST il 59 (314 SF CANOPY rte 0 E�. 12" BRADFORD PY) PEAR (49(��F CANO TO BE REMOVED (3)VIBURNUM x RHYTIDOPHYLLOIDES (74) LIROPE MUSCARI 'BIG BLUE' N/N'N t>t /-(9) ITEA VIRGIN ICA 'HENRY'S EX. ]�" LOCUST EX. 4" LOCUST MIXED GRASS PANELGARNET' (6) HAMAMELIS VIRGINIANA (314 Sl"�.ANOPY 314 SF CANOPY (29) MUHLENBERGIA CAPILARIS BIF (29) PENNISETUM ALOPECUROIDESIF + + MIXED GRASS PANEL EX. 8" CEDAR %(314 SF CANOPY) '(30) MUHLENBERGIA CAPILARIS N ------ IL (30) PENNISETUM ALOPECUROIDES NI N\ EX. 6" CEDAR (�J \ 4 SF SAN 1' (25) ITEA 175 SF CANOPY MIXED GRASS PANEL VIRGINICA V 30) MUHLENBERGIA CAPILARIS /'HENRY'S GARNET' (30) PENNISETUM ALOPECUROIDES (194) LIROPE MUSCARI BLUE' EX. 15" LOCUST Z 490 SF CANOPY 2) ITEA VIRGINICA'HENRY'S i EX. 15" LOCUST, MIXED GRASS PANEL GARNET' + 490SFCAN PY �RASS PANEL (5) MUHLENBERGIA CAPILARIS (5) PENNISETUM ALOPECUROIDES ALOPECUROIDES VIRGINICA ILENBERGIA CAPILARIS N: (25) ITEA /'HENRY'S GARNET' \WN\ (3) ITEA VIRGINICA 'HENRY'S GARNET' MIXED GRASS PANEL U\ N.N. (5) MUHLENBERGIA CAPILARIS (25) ITEA (5) PENNISETUM ALOPECUROIDES VIRGINICA HENRY'S GARNET' (3) ITEA VIRGINICA'HENRY'S -�VGARNET' + (5) PENNISETUM ALOPECUROIDES 'EX. 18" LOCUST MIXED GRASS PANEL (5) MUHLENBERGIA CAPILARIS (24) ITEA N VIRGINICA X (1963 SF ANOPY) 'HENRY'S GARNET' (3) ITEA VIRGINICA 'HENRY'S k ge�GARNET' MIXED GRASS PANEL I ' N. / , / / lI (5) MUHLENBERGIA CAPILARIS fi (5) PENNISETUM ALOPECUROIDES----`/ + + 0 4, (15) FOTHERGILLA + /��� `P l ` / tr � > GARDENII'BLUE MIST' + + -(7) ITEA VIRGINICA 'HENRY'S f GARNET' + + + 4-y+y+y+y+y+�1 + + --�-,,(7) FOTHERGILLA GARDENII EX. 12" DOGWOOD BLUE MIST' N. + + (705 SF CANOPYO) + + + A + + 11 (8) FOTHERGILLA + GARDENII'BLUE MIST' + + Upi IV (136) LIROPE MUSCARI 'BIG BLUE' (8) FOTHERGILLA (218) LIROPE MUSCARI 'BIG BLUE' T, GARDENII'BLUE MIST' EX. 1/5" BRADFORD PEAR -�9,6 SF CANOPY) SP 0 IS \ \N (1) ACER BUERGERIANUM TO BE REMOVED MIXED GRASS PANEL (41) MUHLENBERGIA CAPILARIS (41) PENNISETUM ALOPECUROIDES EX. 30" WILLOW (1,960 SF CANOPY > 3: 71 \ k MIXED GRASS PANEL (140) MUHLENBERGIA CAPILARIS (140) PENNISETUM ALOPECUROIDES --S --s S- FIH IF --7 is M -M -M -m M -M -M -M M MNF M M -M_ ,M -M -M -M -/V 21_ --M M INN C.1) CL 590 M M M rav Waterstreet -A landscape architecture I civil engineering /PS E Mai-, Street 43/,.293.3177 Chariottesville, VA 22902 professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SAPON SWISHER DENTAL project name CHARLES B. SWISHER D.D.S. client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase SEPTEMBER 15, 2017 issue date revisions A k I LANDSCAPE PL/--\IN4 sheet title 0 5 10, 20' sheet number 0 Q MIXED GRASS PANEL I ' N. / , / / lI (5) MUHLENBERGIA CAPILARIS fi (5) PENNISETUM ALOPECUROIDES----`/ + + 0 4, (15) FOTHERGILLA + /��� `P l ` / tr � > GARDENII'BLUE MIST' + + -(7) ITEA VIRGINICA 'HENRY'S f GARNET' + + + 4-y+y+y+y+y+�1 + + --�-,,(7) FOTHERGILLA GARDENII EX. 12" DOGWOOD BLUE MIST' N. + + (705 SF CANOPYO) + + + A + + 11 (8) FOTHERGILLA + GARDENII'BLUE MIST' + + Upi IV (136) LIROPE MUSCARI 'BIG BLUE' (8) FOTHERGILLA (218) LIROPE MUSCARI 'BIG BLUE' T, GARDENII'BLUE MIST' EX. 1/5" BRADFORD PEAR -�9,6 SF CANOPY) SP 0 IS \ \N (1) ACER BUERGERIANUM TO BE REMOVED MIXED GRASS PANEL (41) MUHLENBERGIA CAPILARIS (41) PENNISETUM ALOPECUROIDES EX. 30" WILLOW (1,960 SF CANOPY > 3: 71 \ k MIXED GRASS PANEL (140) MUHLENBERGIA CAPILARIS (140) PENNISETUM ALOPECUROIDES --S --s S- FIH IF --7 is M -M -M -m M -M -M -M M MNF M M -M_ ,M -M -M -M -/V 21_ --M M INN C.1) CL 590 M M M rav Waterstreet -A landscape architecture I civil engineering /PS E Mai-, Street 43/,.293.3177 Chariottesville, VA 22902 professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SAPON SWISHER DENTAL project name CHARLES B. SWISHER D.D.S. client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase SEPTEMBER 15, 2017 issue date revisions A k I LANDSCAPE PL/--\IN4 sheet title 0 5 10, 20' sheet number I . DETECTABLE WARNING TO BE CLASS A-3 CONCRETE (CLASS A-4 IF PRECAST) WITH SLIP RESISTANT INTEGRAL SURFACE COVERING THE FULL WIDTH OF THE RAMP FLOOR BY 2 FOOT IN LENGTH IN THE DIRECTION OF PEDESTRIAN TRAVEL OTHER TYPES OF MATERIAL WITH THE TRUNCATED DOME DETECTABLE WARNING MAY BE USED WITH THE APPROVAL OF THE ENGINEER. 2. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. TRUNCATED DOMES TO BE STAMPED IF (CAST -IN-PLACE OR PRECAST IN TOP SURFACE, THE COLOR OF THE DETECTABLE WARNING SECTION SHALL BE A CONTRASTING COLOA WITH THE ADJACENT SURFACES (ADJACENT SURFACES INCLUDES FLARED SIDES). OR FEDERAL SAFETY YELLOW. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP FLOOR OR BY USING PERMISSIBLE: CONSTRUCTION JOINT WITH REQUIRED BARS. 4. IF RAMP FLOOR IS PRECAST, HOLES MUST BE PROVIDED FOR DOWEL BARS SO THAT ADJOINING FLARED SIDES CAN BE CAST IN PLACE AFTER PLACEMENT OF PRECAST RAMP FLOOR. PRECAST CONCRETE SHALL BE CLASS A-4. 5. REQUIRED BARS ARE TO BE NO, 5 X 8" PLACED Y CENTER TO CENTER ALONG BOTH SIDES OF THE RAMP FLOOR, M11D-DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 1YY. 6. CURB/CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURE$/CURB AND GUTTER. 7. CURB RAMPS ARE TO BE LOCATED AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. THEY ARE TO BE PROVIDED AT INTERSECTIONS WHEREVER AN ACCESSIBLE ROUTE WITHIN THE RIGHT OF WAY OF A HIGHWAY FACILITY CROSSES A CURB REGARDLESS OF WHETHER SIDEWALK IS EXISTING, PROPOSED, OR NONEXISTENT. THEY MUST BE LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER, AND SHOULD NOT BE LOCATED BEHIND VEHICLE STOP LINES. EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. ACCESSIBLE ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS, 8. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT THE CURB OPENING IS PLACED `6VITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS PERPENDICULAR TO THE CURB. 9. TYPICAL CONCRETE SIDEWALK IS 4" THICK. WHEN THE ENTRANCE RADII CANNOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK TRAFFIC THE CONCRETE SIDEWALK DEPTH SHOULD BE INCREASED TO 7". PERMISSIBLE CONSTRUCTION JOINT # 5 DOWELS, 8" LONG A PERMISSIBLE AT 12" C -C {I CONSTRUCTION 5' MIN. JOINT SECTION B -B 2:1 Q z 12:1 MAXI B 2.. ,�,,.� B,n T2 MA A TRUNCATED DOMES 5-0" MIN, SHAPE TO MATCH FACE OF ROADWAY CURB— BACK OF CURB 20: 1–, 2' MIN I SECTION A -A --27" C -C TRUNCATED DOME ... i {J 0 C 0 U O O 0 ti 0 0 0 O G 0 0 0 Q 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C, O n o O 2%"CC o 0( 0 00001 00000 00 0 O O G G 0 J 0 0 0 0 O 0 G C, :.0 N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C: r;- C 0 C 0 0 O% t C,, 0 0 o 00 C 0000 000000010 VARIABLE 4' MINIMUM. PAY LIMITS DETECTABLE WARNING DETAIL J Q o� t U CROSSWALK TYPICAL PLACEMENT AT INTERSECTION WITHIN CROSSWALK NOTE: ALL DETECTABLE WARNING AERAS SHALL BE PAINTED YELLOW UNLESS AN EXISTING CONDITION IS ALREADY PRESENT. CG -12 HC -RAMP SCALE: NTS YV DIA. DIA. TRUNCATED DOME DETAIL CG -12 DETECTABLE WARNING SURFACE (ACCESS FOR MOBILITY IMPAIRMENTS) VIRGINIA DEPARTMENT OF TRANSPORTATION NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. SEE 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG NOTE 4 FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB, 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. 5. THIS CURB IS TO BE USED WHEN DESIGN SPEED IS 40 MPH OR LESS ON RURAL HIGHWAYS AND 45 MPH OR LESS IN DEVELOPED URBAN AND SUBURBAN AREAS. IF THESE DESIGN SPEEDS ARE EXCEEDED STANDARD CG -3 IS REQUIRED, VDOT STD CG -2 SCALE : NTS 2" O HOLE FULL TRIC NTS g. 0.. 2- #3 REBi 8 ° 4.. ° z TOP VIEW 12 .1"0 O A" I— -, 2" 5 2 u 32 ,A, SIDE VIEW z SECTIION "A" ENLARGED CONCRETE WHEEL STOP SCALE : NTS EXPANSION JOINT NOT NO %z" EXPANSION JOINT W/%z" RECESSED BACKER ROD AND CAULK, SPACED 1 %4' DEEP CONTRACTION/SCOREEVERY 25' (MIN) O.C.; TYP. OR AS SHOWN PER PLANS JOINT, SPACED EVERY 5' O.C.; 'TYP. OR AS SHOWN PER PLANS 3000 PSI CONCRETE AT 28 DAYS, AIR -ENTRAINED F6 X6 W WW 14XW14W/2" ', �� \\�* '� �,; MIN. COVER -ONLY WHEN / ;/fid\ ,�,� ��`�°/ f f ,r�si` s���WHERE VEHICULAR TRAFFIC IS EXPECTED TO OCCUR 1�rd,�,e BASE PACTE D VDOT #21A STONE SECTION 95% COMPACTED SUBGRADE SCALE: NTS WE MW I ZAF Aw +' MMPRESStON x 3/4" MALE PIPE COUPLING PPROVED EQUAL DUAL SERVICE FOR USE ON ATTACHED SINGLE FAMILY RESIDENTIAL SERVICES OR DUAL RESIDENTIAL AND IRRIGATION SERVICES. 2' R ' ^OMPRESSION x 3/4" MALE PIPE COUPLING PPROVED EQUAL SINGLE SERVICE NOTE: 1) SADDLES SHALL BE USED ON PVC PIPE. 1/8 BEND COI FOR USE ON DETACHED SINGLE FAMILY RESIDENTIAL SERVICE WHERE AN IRRIGATION METER IS NOT PROVIDED. CAST IRON LID RADE :TER (x OPPERSETTER :TER AS vv" v V NECESSARY TYPICAL SERVICE LATERAL_ INSTALLATION (5/8" & 1" METERS) NTS FIG. W -6A TD -10 TYPICAL WATER SERVICE LATERAL- SCALE: ATERAL SCALE: NTS �I X HANDICAP SIGN - BLUE BACKGROUND, WHITE 'LETTERING (MUTCD R7-8 (VIRGINIA) MANY BE SUBSITUTED AS EQUIVILENT) 12" X 12" PENALITY FINE PLACECARD MAY BE ADDED BELOW PRIMARY SIGN (IF REQUIRED BY LOCAL AUTHORITIES) SIGN MUTCD R7 -8B SHALL BE INSTALLED AT SPACES WHICH ARE VAN ACCESSIBLE ONLY AS SHOWN ON PLANS METAL SIGN POST - 84" CLEAR MIN. WHEN PEDESTRIAN PATH FROM CAR TO WALK PASSES BY OR UNDER THE SIGN FINISHED GRADE CONCRETE FOOTING (CLASS B) 2000 PSI MIN. COMPACTED SUBGRADE w a t e r s t r e e t r_l 10 landscape architecture I civil engineering a18 E Main Street 434,2915-8177Clallottes✓ille, VA 229oz PENALTY $100-$500 FINE - - TOW -AWAY ZONE MUTCD R7-8 (VA) NOTES: 1. METAL POST SHALL BE GALVANIZED OR BAKED ENAMEL HIGH STRENGTH U -CHANNEL. POST SHALL HAVE 3/8" DIA, PRE -DRILLED HOLES THAT ARE 1" ON CENTER FOR MOUNTING SIGNS. BAKED ENAMEL POST COLOR SHALL BE BLACK. 2. ALL BOLTS, NUTS, WASHERS, & SCREWS SHALL BE GALVANIZED. 3. SIGNS SHALL BE FABRICATED BY USING A REFLECTIVE COATING IN THE SYMBOL, MESSAGE, AND BORDERS APPLIED TO A SHEET ALUMINUM BACKING (.080") IN THICKNESS. 4. MESSAGE LETTERING SHALL BE UPPER CASE (WHITE SERIES B) IN ACCORDANCE WITH MUTCD. 5, THE SYMBOL IS COMPOSED OF TWO ELEMENTS. A WHITE WHEELCHAIR FIGURE (WHICH ALWAYS FACES RIGHT) ON A SQUARE BACKGROUND, INTERNATIONAL BLUE IN COLOR (FED. STD. 595A, COLOR #15180) 6. SIGN POST SHALL HAVE MIN. 6" CLEARANCE FROM BACK OF CURB AND PLACED AS SHOWN ON PLANS. 7. ANY SIGNS MOUNTED TO ONE POST SHALL BE SPACED 2" APART. SCALE: NTS SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% (1 /4" PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. / 2' MIN 1 I SALT TREATED FINISHED GROUND 2 x 4 MARKER SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 TD -31 TYPICAL SANITARY LATERAL- SCALE: ATERAL SCALE: NTS professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SAPON SWISHED DENTAL project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions SITE DETAILS sheet title sheet number o A 4' SQUARE LANDING AREA ➢� OUTSIDE OF TRAVELWAY SHALL BE PROVIDED FOR CROSSWALK PERPENDICULAR CROSSWALK WITHIN THE MARKED CROSSWALK AREA. YV DIA. DIA. TRUNCATED DOME DETAIL CG -12 DETECTABLE WARNING SURFACE (ACCESS FOR MOBILITY IMPAIRMENTS) VIRGINIA DEPARTMENT OF TRANSPORTATION NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. SEE 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG NOTE 4 FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB, 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. 5. THIS CURB IS TO BE USED WHEN DESIGN SPEED IS 40 MPH OR LESS ON RURAL HIGHWAYS AND 45 MPH OR LESS IN DEVELOPED URBAN AND SUBURBAN AREAS. IF THESE DESIGN SPEEDS ARE EXCEEDED STANDARD CG -3 IS REQUIRED, VDOT STD CG -2 SCALE : NTS 2" O HOLE FULL TRIC NTS g. 0.. 2- #3 REBi 8 ° 4.. ° z TOP VIEW 12 .1"0 O A" I— -, 2" 5 2 u 32 ,A, SIDE VIEW z SECTIION "A" ENLARGED CONCRETE WHEEL STOP SCALE : NTS EXPANSION JOINT NOT NO %z" EXPANSION JOINT W/%z" RECESSED BACKER ROD AND CAULK, SPACED 1 %4' DEEP CONTRACTION/SCOREEVERY 25' (MIN) O.C.; TYP. OR AS SHOWN PER PLANS JOINT, SPACED EVERY 5' O.C.; 'TYP. OR AS SHOWN PER PLANS 3000 PSI CONCRETE AT 28 DAYS, AIR -ENTRAINED F6 X6 W WW 14XW14W/2" ', �� \\�* '� �,; MIN. COVER -ONLY WHEN / ;/fid\ ,�,� ��`�°/ f f ,r�si` s���WHERE VEHICULAR TRAFFIC IS EXPECTED TO OCCUR 1�rd,�,e BASE PACTE D VDOT #21A STONE SECTION 95% COMPACTED SUBGRADE SCALE: NTS WE MW I ZAF Aw +' MMPRESStON x 3/4" MALE PIPE COUPLING PPROVED EQUAL DUAL SERVICE FOR USE ON ATTACHED SINGLE FAMILY RESIDENTIAL SERVICES OR DUAL RESIDENTIAL AND IRRIGATION SERVICES. 2' R ' ^OMPRESSION x 3/4" MALE PIPE COUPLING PPROVED EQUAL SINGLE SERVICE NOTE: 1) SADDLES SHALL BE USED ON PVC PIPE. 1/8 BEND COI FOR USE ON DETACHED SINGLE FAMILY RESIDENTIAL SERVICE WHERE AN IRRIGATION METER IS NOT PROVIDED. CAST IRON LID RADE :TER (x OPPERSETTER :TER AS vv" v V NECESSARY TYPICAL SERVICE LATERAL_ INSTALLATION (5/8" & 1" METERS) NTS FIG. W -6A TD -10 TYPICAL WATER SERVICE LATERAL- SCALE: ATERAL SCALE: NTS �I X HANDICAP SIGN - BLUE BACKGROUND, WHITE 'LETTERING (MUTCD R7-8 (VIRGINIA) MANY BE SUBSITUTED AS EQUIVILENT) 12" X 12" PENALITY FINE PLACECARD MAY BE ADDED BELOW PRIMARY SIGN (IF REQUIRED BY LOCAL AUTHORITIES) SIGN MUTCD R7 -8B SHALL BE INSTALLED AT SPACES WHICH ARE VAN ACCESSIBLE ONLY AS SHOWN ON PLANS METAL SIGN POST - 84" CLEAR MIN. WHEN PEDESTRIAN PATH FROM CAR TO WALK PASSES BY OR UNDER THE SIGN FINISHED GRADE CONCRETE FOOTING (CLASS B) 2000 PSI MIN. COMPACTED SUBGRADE w a t e r s t r e e t r_l 10 landscape architecture I civil engineering a18 E Main Street 434,2915-8177Clallottes✓ille, VA 229oz PENALTY $100-$500 FINE - - TOW -AWAY ZONE MUTCD R7-8 (VA) NOTES: 1. METAL POST SHALL BE GALVANIZED OR BAKED ENAMEL HIGH STRENGTH U -CHANNEL. POST SHALL HAVE 3/8" DIA, PRE -DRILLED HOLES THAT ARE 1" ON CENTER FOR MOUNTING SIGNS. BAKED ENAMEL POST COLOR SHALL BE BLACK. 2. ALL BOLTS, NUTS, WASHERS, & SCREWS SHALL BE GALVANIZED. 3. SIGNS SHALL BE FABRICATED BY USING A REFLECTIVE COATING IN THE SYMBOL, MESSAGE, AND BORDERS APPLIED TO A SHEET ALUMINUM BACKING (.080") IN THICKNESS. 4. MESSAGE LETTERING SHALL BE UPPER CASE (WHITE SERIES B) IN ACCORDANCE WITH MUTCD. 5, THE SYMBOL IS COMPOSED OF TWO ELEMENTS. A WHITE WHEELCHAIR FIGURE (WHICH ALWAYS FACES RIGHT) ON A SQUARE BACKGROUND, INTERNATIONAL BLUE IN COLOR (FED. STD. 595A, COLOR #15180) 6. SIGN POST SHALL HAVE MIN. 6" CLEARANCE FROM BACK OF CURB AND PLACED AS SHOWN ON PLANS. 7. ANY SIGNS MOUNTED TO ONE POST SHALL BE SPACED 2" APART. SCALE: NTS SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% (1 /4" PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. / 2' MIN 1 I SALT TREATED FINISHED GROUND 2 x 4 MARKER SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 TD -31 TYPICAL SANITARY LATERAL- SCALE: ATERAL SCALE: NTS professional seal ALAN FRANKLIN project manager LUKE WALDRON project team SAPON SWISHED DENTAL project name CHARLES B. SWISHER D.D.S. MARK SAPPON D.D.S client 259 HYDRAULIC RIDGE RD, STE 203 CHARLOTTESVILLE, VA 22901 project address project number MAJOR SITE PLAN AMENDMENT project phase OCTOBER 23, 2017 issue date revisions SITE DETAILS sheet title sheet number