Loading...
HomeMy WebLinkAboutWPO200400004 Review Comments As-Built Reviews 2017-12-04Emily Cox From: Repp Glaettli Sent: Monday, December 04, 2017 3:39 PM To: Emily Cox Subject: RE: Planning Application Review for WP0200400004 Old Trail - Upper Ballard Field - SW. Site inspection for bond release 12/4/17 Major: • no water in retention basin, aquatic plants are at greater risk of expiring • riser structure is welded shut, per as -built o the maintenance plan requires that the valve be checked annually within riser o unable to inspect inside Minor: • 200 cattails and 2000 wild celery were not visually present • invert of inlet culvert is partially or fully below the water surface elevation, about one foot • temporary and/or permanent grass are not fully established, grass is just beginning to come in o provide invoice for seed? • outlet pipe invert appears to be marginally, less than one foot, lower than discharge channel o risk of standing water adjacent to road Recommendation: • release bond, post construction inspector will address problems listed above • as -built plan and site appear to consistent with each other Repp Glaettli From: Emily Cox Sent: Monday, December 04, 2017 10:51 AM To: Repp Glaettli <rglaettli@albemarle.org> Subject: RE: Planning Application Review for WP0200400004 Old Trail - Upper Ballard Field - SW. Great, thanks! Emily Cox, PE Civil Engineer II (434) 296-5832 Ext. 3565 401 McIntire Rd. Charlottesivlle, VA 22902 www.albemarle.org 1