HomeMy WebLinkAboutWPO200400004 Review Comments As-Built Reviews 2017-12-04Emily Cox
From: Repp Glaettli
Sent: Monday, December 04, 2017 3:39 PM
To: Emily Cox
Subject: RE: Planning Application Review for WP0200400004 Old Trail - Upper Ballard Field -
SW.
Site inspection for bond release 12/4/17
Major:
• no water in retention basin, aquatic plants are at greater risk of expiring
• riser structure is welded shut, per as -built
o the maintenance plan requires that the valve be checked annually within riser
o unable to inspect inside
Minor:
• 200 cattails and 2000 wild celery were not visually present
• invert of inlet culvert is partially or fully below the water surface elevation, about one foot
• temporary and/or permanent grass are not fully established, grass is just beginning to come in
o provide invoice for seed?
• outlet pipe invert appears to be marginally, less than one foot, lower than discharge channel
o risk of standing water adjacent to road
Recommendation:
• release bond, post construction inspector will address problems listed above
• as -built plan and site appear to consistent with each other
Repp Glaettli
From: Emily Cox
Sent: Monday, December 04, 2017 10:51 AM
To: Repp Glaettli <rglaettli@albemarle.org>
Subject: RE: Planning Application Review for WP0200400004 Old Trail - Upper Ballard Field - SW.
Great, thanks!
Emily Cox, PE
Civil Engineer II
(434) 296-5832 Ext. 3565
401 McIntire Rd.
Charlottesivlle, VA 22902
www.albemarle.org
1