HomeMy WebLinkAboutARB201700135 Staff Report 2018-01-12ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB-2017-125: Seminole North Comprehensive Sign Plan
Review Type
First review of a Comprehensive Sign Plan
Parcel Identification
032000000005BO
Location
4257 Seminole Trail
Zoned
Light Industry (LI)/Entrance Corridor (EC)
Owner/Applicant
Seminole North LLC/Hightech Signs
Magisterial District
Rio
Proposal
To establish comprehensive sign criteria for a multi -tenant building. (See page 3 and Attachment A for the detailed
proposal.)
Context
The site was developed in 1968 as Electronics Concepts, Inc. An office fronts warehouses, all of which are surrounded
by paving. There are wooded areas and steep slopes descending to the North Fork of the Rivanna River on the east and
south sides of the property. Commercial, office and industrial properties are located to the north. Residential
developments are located in the general area.
Visibility
The north and west (EC) elevations of the building are clearly visible from the EC.
ARB Meeting Date
January 16, 2018
Staff Contact
Margaret Maliszewski
-r -
t
A Iva 0.
Seminole North building, Rt. 29.
PROJECT HISTORY
Comprehensive sign plans are required for buildings in the Entrance Corridors that house multiple tenants. Wall signs for the ABC Supply Co. were
approved in 2015 (Attachment B). A sign application was submitted for City Electric Supply (CES) in 2017 (Attachment Q. As the second sign on the
building, approval of a Comprehensive Sign Plan for the property was required prior to approval of the sign (Attachment D). Such proposal was not
received and the CES sign was installed without an approved permit. A sign application was also received for Cville Classic Cars (CCC) in 2017
(Attachment E). Because a Comprehensive Sign Plan had still not been submitted for review, the sign could not be reviewed/approved. That sign was
installed without an approved permit. Signs for Builders First Source (BFS) and Roberts Home Medical (RHM) have been installed without approved
permits, and with no applications submitted. The BFS sign is a metal panel. The RHM sign is a vinyl banner. A pre-existing freestanding sign stands
along the Rt. 29 frontage of the property. A refacing of the sign was approved in 2016 to include signs for Pro -Build (no longer advertised), ABC Supply
Co., and leasing information (Attachment F). CES, CCC, BFS and RHM have all installed tenant panels on this sign (Attachment G). The CES and CCC
sign applications include the installed tenant panels. (See photos of installed wall signs, below.)
Date
Application
Result
10/27/2015
ARB-2015-117
ABC Supply Co., Inc. wall sign (channel letters and subordinate non -illuminated panel at south end of building) and
awning signs approved (Attachment B).
4/4/2016
ARB-2016-17
Refacing of the Seminole North freestanding sign approved (Attachment F).
3/22/2017
ARB-2017-24
City Electric Supply sign application received for a wall sign and refacing of the freestanding sign (Attachment C).
In February, prior to application submittal, staff asked the ARB for direction regarding the internal illumination of
the flag portion of the sign. It was the consensus of the ARB that the sign should not be internally illuminated, but it
could be externally illuminated.
4/6/2017
Applicant was informed that application can't be reviewed until a Comprehensive Sign Plan is submitted, reviewed
and a proved and that the sign doesn't meet the sign guidelines. See Attachment D for comment letter.
6/7/2017
ARB-2017-59
Cville Classic Cars sign application received for a wall sign and refacing of the freestanding sign (Attachment E).
6/12/2017
Applicant informed that application can't be reviewed until a Comprehensive Sign Plan is submitted, reviewed and
approved.
Builders
11 FirstSource
vor-
O ED RTS
HOME MEDICAL, fNG
,rqvor-
Ij
Installed wall signs (photographed 1/2018)
CITY ELECTRIC SUPPLY
S ^r• 1
PROPOSED COMPREHENSIVE SIGN CRITERIA
This table outlines the design criteria proposed by the applicant for wall signs for the Seminole North building. See Attachment A for proposed sign
locations.
SIGNTYPE
Channel Lotter
Cabinet Signs and Panel Signs
Awnings
LOCATION(S)
Ctntcrtd horizontally and vertically in the
Centered horizontally and vertically
Awnings shall be located it)
approved sign band areas, as ShOWn OR LVIC
in the, approved sign hand areas, as
maintai-i compatibility with
cleva6on photos (attached)-
shown on the elevation phran.;.
windew and door openings -
LETTER FACE COLOR
White, red, blue., green, black, or culors
N/A
NIA
uumparable to and cumpatible. with
Signs at site.
TRIM CAP
Black, bronze., white, or rnaichcd Lt.)
Hl;--Eck, hrnn7.e,,6vhite. -iiqrrfl&d w
N/A
C01,0111RETURN COLOR
.,ign face.
sign J'Acc.
RACEWAY COLOR
NfA-, channel letters are direct mounted %T/ A
N/A
CABINET FACE COLORS
NIA
Colooi comparable to and
N/A
compail ble with e xil sting s Igil ,, al site.
SIZE LLM[ITATIONS Accurding to ZOnilLg 0rclma.-icc
According to Zoning OrdimAce
Accur-ding to Z0njY1g Ordinance.
LOGOIGRAPHICS
No li nil t to graphic colors as long �. s U ic
No li rni t lea praph ic co I org as i ong as the
Letteringilogo may appear on fact
DETAILS
tntzl ntiriheir is I I railed to three, Plus
total rwinher is limited to three, plus
of awl)i T)g Qt_ Valalice -arr-"i,
black and w1ute,
black and w1ute-
ILLUMINATION hitemal1v Illuminated
Non-11fuinimaud, internally illuminawd,
Non-illvminated. or internally
DETAILS
or externally illuminattol.
illuminated,
I.FTTFR TYPEAFONT
No restriction
No restriction
No restriction
MATERIAI.,% Alum Hii al, acrvl ic, viDyl
I I
Aluniinwu; acrylic, vinyl
Duldnor fabuir, iinetal
ANAYLSIS This table provides an analysis of how the proposed Comprehensive Sign Plan meets the EC Sign Guidelines.
REF
GUIDELINE
ISSUE
RECOMMENDATION
Sign Type
1
Create a consistent and unified design approach
Multiple sign types are proposed: channel letters,
Sign types shall be limited to
along the Entrance Corridors.
cabinets, panels and awning signs. Generally, the
use of a combination of letters, panels and
individual letters, panels, and
traditional awning signs. When
2
Establish simplicity and reserve as preferred
characteristics for sign design in these areas.
cabinets does not contribute to simplicity,
reserve, or a consistent and unified design on a
individual letter signs and panel
signs are used together, the
9b
Channel lettering (mounted on a raceway or
individual letters) is preferred to cabinet signs
building. However, the large size of the Seminole
individual letter sign shall read
North building suggests that it could
accommodate more than one sign type. The ABC
visually as the primary sign.
1 Ob
b. Multiple business centers shall use a single
sign type for all wall signs.
Supply Co. sign was approved as a combination
of a primary individual letter sign and a
secondary panel sign, both non -illuminated. This
combination has an organized and orderly
appearance in which the multiple sign types
appear coordinated and do not negatively impact
the overall appearance. Traditional awning signs
consisting of letters on the canopy or valance, as
in the ABC sign, have a reserved appearance that
is appropriate for the EC.
Placement, Scale and Size
4a
The design of a building's walls, window
Sign bands proposed for the building appear to
Revise the criteria and sign
locations, parapets and other architectural
be designed to accommodate the signs that have
bands to provide a minimum of
features shall influence the Board's evaluation
already been installed (most without permits) and
12" of clear space between the
of appropriate signage. Wall signs can help
to allow for signs across the full length of the
edge of the sign band and the
establish rhythm, scale and proportion across the
building as close to the top of the wall as
sides of the awnings, the gutter
fagade of a building.
possible. Architectural features would not be
obscured by signs in these locations, but signs
at the top of the building, and
all window and door openings
10d
Signs must be placed on the building in a
manner that establishes a unified appearance.
will appear crushed at the top of the building (as
in the CES sign) and against awnings and
to establish a more unified and
less cluttered appearance.
9a
Wall signs shall be integrated with the
architecture of the building and the placement of
window/door openings. Moving the sign bands
such signs should not obscure architectural
away from the awnings, away from the gutter at
Add dimensions to clarify the
features or details, including but not limited to
the top of the building, and away from window
size and location of the
cornices, windows, columns, pilasters and
and door openings would provide for a more
proposed sign bands.
paneling.
unified, integrated, and less cluttered appearance.
Although the guidelines suggest 6" of clear space
Revise the CSP "size
9d
The size of a wall sign shall be coordinated with
the size of the architectural element on which it
in a 30" sign band, 6" is expected to appear too
limitation" entries to read,
is placed. The sign should not overcrowd the
small on a building of this scale. 12" would
"According to Zoning
architectural element, the wall, or the sign area.
appear more appropriate, but this may not allow
Ordinance and Entrance
Buildings and building elements should not be
for readable signage above doors with awnings.
Corridor Design Guidelines".
used as a billboard. For example, an appropriate
(The amount of wall space between gutter and
height for channel letters in a 30" high sign band
awning is not identified on the drawings.)
is 18". This allows 6" of unoccupied space
above and below the letters. Generally, 4" of
No dimensions are provided on the drawings that
clear space above, below, and to the sides of a
illustrate proposed sign locations. Dimensions
channel letter sign is considered a minimum,
are needed to establish consistent scale and
with larger clearances required for larger sign
proportion.
bands. The ARB will consider the degree of
visibility, the distance from the Entrance
The proposed CSP states that sign size is limited
Corridor, and the architectural design of the
as per the zoning ordinance. Regulations of the
building and the sign area in its determination of
sign ordinance and the EC sign guidelines apply.
appropriate sizes and placement.
4c
Materials: Materials used in both the sign and
Standard materials are proposed: aluminum,
None.
support structures should complement the
acrylic, vinyl, fabric. These are expected to have
building and/or multiple business center being
an appropriate appearance from the EC.
served by the sign.
4d
Lettering and Typeface: Lettering should be in
No limits on font or typeface are proposed. The
None.
proportion to the sign and the building for visual
distance of the building from the road and the
clarity and overall balance. Proportion of
distance between signs on the building tend to
lettering includes font (size) and typeface
limit the impact of multiple typefaces in this
(style). The use of three typefaces or fewer is
case.
more appropriate for signs in the Entrance
Corridor. Additional typefaces may be approved
only if they contribute to a balanced, legible,
unified sign design.
l Oc
Compatibility among signs must be maintained
through color or font and typeface selection.
4e
Color: Colors must be harmonious with each
The proposal is not consistent with the guidelines
The colors of the faces of
9c
other. Colors must not clash with other elements
regarding number of colors. For letter faces, the
individual letter signs shall be
on the site, both when viewed in daylight and at
applicant proposes red, white, blue, black, green
limited to red, white, blue and
night, whether the signs are externally or
and colors comparable to and compatible with
black. Red shall match Pantone
internally lit. Overly intense color, such as but
existing signs at the site. Specific color numbers
186. Blue shall match Pantone
not limited to dayglo or fluorescent colors, are
are not identified. Although green is proposed,
280.
prohibited.
green is not visible in any of the installed signs
or illustrated in the submittal materials.
Panel face colors shall be
The use of three colors or fewer is more
limited to white. Panel text
appropriate for signs in the Entrance Corridor.
Trim cap and return colors are proposed as black,
colors shall be red, blue or
Black and white are counted as colors.
bronze, white or to match the sign face. This is
black. Red shall match Pantone
Additional colors may be approved if they
expected to have an appropriate appearance from
186. Blue shall match Pantone
contribute to a balanced and unified sign design.
the EC.
280.
For raceway -mounted channel letters, raceways
Cabinet and panel face colors are proposed as
shall match the wall color.
"comparable to and compatible with existing
signs at the site." This criterion does not establish
10c
Compatibility among signs must be maintained
through color or font and typeface selection.
a clear expectation and is difficult to work with.
With the recommended letter colors, panels with
white faces and red, blue or black letters would
maintain compatibility across the building.
The approved ABC sign colors are Pantone red
186 and Pantone blue 280.
4f
Trademarks, corporate logos and graphics:
The applicant proposes no limit to graphic
Graphics colors shall be limited
The ARB may require that the color and scale of
colors, as long as the number does not exceed
to Pantone red 186, Pantone
standard templates for trademarks, service
three, plus black and white. Graphics have been
blue 280, white and black.
marks, corporate logos and graphics be
installed with the CES sign (a cabinet in the
modified. When used, trademarks, service
shape of the Unites States, rendered as a red,
marks, corporate logos and/or graphics should
white and blue flag), the CCC sign (two blue
be incorporated as an integral part of the overall
horizontal lines), the Roberts Medical sign (a red
sign.
line), and the Builders First Source sign (a red
square). Given the recommendations on letter
and panel colors, together with the installed
signs, graphics colors limited to red, white, blue
and black would have an appropriate appearance.
Illumination
5a
When illumination is required, the preferred
Internall, external and no illumination are all
Illumination shall be limited to
solution is to externally illuminate the sign — in
proposed as options for wall signs on this
internal illumination of
other words, to shine a light on the sign....
building.
individual channel letters and
9
i. External illumination is preferred for wall
external or no illumination of
5c
signs, for signs in multiple business centers, and
The ABC wall sign was approved as a non-
secondary panel signs.
l Oe
for graphics/logos. The Board will evaluate the
illuminated sign. All three parts of the CES sign
specific design for size, balance, complexity,
are internally illuminated. The letters and
Awning signs shall not be
and distance from/relationship to the Entrance
horizontal lines of the CCC sign are internally
illuminated.
Corridor...
illuminated. The BFS sign has an external light
fixture. The RHM sign is non -illuminated. If the
5b
Since external illumination does not fit every
case, individual channel letters ... may also be
sign type is limited to individual letters and
approved. Channel letters are generally the
secondary panel signs (non- or externally
preferred type of internally illuminated wall sign
illuminated), then internal illumination of
... When channel letters cannot be adequately
channel letters could have an appropriate
accommodated, internally illuminated cabinet
appearance.
signs may be considered. If cabinet signs are
utilized, the backgrounds of such signs must be
The proposed criteria indicate that awning signs
made opaque zero light transmission).
could be internally illuminated. This would not
have an appropriate appearance for the EC.
5 f
Internal Illumination: Any internal illumination
is considered to contribute to visual clutter and
will be limited.
9
iv. Cabinet signs shall have a non -illuminated
The proposed plan does not address the
Graphics shall not be internally
10e
background, or an opaque (zero light
requirement for opaque backgrounds on cabinet
illuminated.
transmission) background. Cabinet signs shall
signs. The traditional cabinet style sign is not a
be constructed such that no light spills outward
recommended sign type for this building.
from the top, bottom, sides or back. If outlines
However, some graphics are constructed like
of letters are proposed, the width of the outline
cabinets — boxes of varying shape with internal
must be in proportion to the width of the letter.
illumination. Interior illumination of this sign
An outline width of 1/8" has been found to be an
type is not recommended.
appropriate dimension for signs in the Entrance
Corridors.
City Electric Supply Sign
Since the time the CES sign application was
Revise the CES wall sign
received, an awning has been installed over the
application to illustrate a design
door, so the sign location illustrated in the
that meets the approved
application is not accurate. The proposed sign is
Comprehensive Sign Criteria.
not consistent with the recommended criteria
Provide dimensions on the sign
regarding sign type, sign color, illumination, or
drawing defining the distance
placement. The overall sign has a cluttered,
from the sign to nearby
disorganized appearance that is not appropriate
architectural elements (roof,
for the EC.
window, door opening, etc.).
Cville Classic Cars Sign
The CCC sign appears to have been installed in a
Revise the CCC wall sign
location different from the one illustrated in the
application to show an accurate
sign application. The proposed color is Pantone
location and to meet all
blue 280. The entire sign is proposed to be
approved criteria. Provide
internally illuminated, including the two
dimensions on the sign drawing
horizontal lines. Although the lines may be
defining the distance from the
considered graphics, they are fully integrated
sign to nearby architectural
with the sign and the illumination of the lines is
elements (roof, window, door
not expected to have a negative impact.
opening, etc.).
Roberts Home Medical Sign
The RHM sign is a vinyl banner. No details have
Submit a sign application for
been submitted.
the RHM sign that is consistent
with all approved Criteria.
Provide dimensions on the sign
drawing defining the distance
from the sign to nearby
architectural elements (roof,
window, door opening, etc.).
Builders First Source Sign
The BFS sign is a metal panel sign. No details
Submit a sign application for
have been submitted.
the BFS sign that is consistent
with all approved Criteria.
Provide dimensions on the sign
drawing defining the distance
from the sign to nearby
architectural elements (roof,
window, door opening, etc.).
Freestanding Sign
Approved freestanding sign colors include:
Freestanding sign letter and
Pantone 280C Blue, Pantone 301C Blue, Pantone
graphic colors shall be limited
186C Red, Pantone Black, Pantone 348C Green,
to Pantone 280 blue, Pantone
and Pantone 464C Brown.
301 blue, Pantone 186 red,
Pantone 200 red, black, and
Proposed freestanding sign colors include:
white.
• CES: Pantone red 200C, black, white,
charcoal grey, red/white/blue digital graphics
The freestanding sign shall
(no color numbers provided)
have a white background.
• CCC: Pantone 280 blue
• RHM: Unknown
• BFS: Unknown
The Pantone 200 red color proposed for the CES
freestanding sign is sufficiently similar to the
previously approved Pantone 186 that it is
expected to appear coordinated as it is used in the
freestanding sign.
The ProBuild sign is no longer in place, so green
and brown appear to no longer be needed for the
freestanding sign.
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. The appropriate number of wall sign types, colors, and illumination for this building.
2. The appropriate locations for wall signs on this building
3. The amount of clear space needed between signs and architectural elements.
4. The appropriate colors and illumination of graphics in wall signs.
5. Colors for the freestanding sign.
Regarding the proposed Comprehensive Sign Criteria, staff recommends approval of a Comprehensive Sign Plan that fully addresses the following issues:
1. Sign types shall be limited to individual letters, panels, and traditional awning signs. When individual letter signs and panel signs are used together,
the individual letter sign shall read visually as the primary sign.
2. Revise the CSP and sign bands to provide a minimum of 12" of clear space between the edge of the sign band and the sides of the awnings, the
gutter at the top of the building, and all window and door openings to establish a more unified and less cluttered appearance.
3. Add dimensions to clarify the size and location of the proposed sign bands.
4. Revise the CSP "size limitation" entries to read, "According to Zoning Ordinance and Entrance Corridor Design Guidelines".
5. The colors of the faces of individual letter signs shall be limited to red, white, blue and black. Red shall match Pantone 186. Blue shall match
Pantone 280.
6. Panel face colors shall be limited to white. Panel text colors shall be red, blue or black. Red shall match Pantone 186. Blue shall match Pantone 280.
7. Graphics colors shall be limited to Pantone red 186 and Pantone blue 280.
8. Illumination shall be limited to internal illumination of individual channel letters and external or no illumination of secondary panel signs.
9. Awning signs shall not be illuminated.
10. Graphics shall not be internally illuminated.
Regarding the individual signs that have been installed without permits, staff recommends the following:
11. Revise the City Electric Supply wall sign application to illustrate a design that meets the approved Comprehensive Sign Criteria. Provide
dimensions on the sign drawing defining the distance from the sign to nearby architectural elements (roof, window, door opening, etc.).
12. Revise the Cville Classic Cars wall sign application to show an accurate location and to meet all approved Comprehensive Sign Criteria. Provide
dimensions on the sign drawing defining the distance from the sign to nearby architectural elements (roof, window, door opening, etc.).
13. Submit a sign application for the Roberts Home Medical sign that is consistent with all approved Comprehensive Sign Criteria. Provide dimensions
on the sign drawing defining the distance from the sign to nearby architectural elements (roof, window, door opening, etc.).
14. Submit a sign application for the Builders First Source sign that is consistent with all approved Comprehensive Sign Criteria. Provide dimensions on
the sign drawing defining the distance from the sign to nearby architectural elements (roof, window, door opening, etc.).
15. Freestanding sign letter and graphic colors shall be limited to Pantone 280 blue, Pantone 301 blue, Pantone 186 red, Pantone 200 red, black, and
white.
16. The freestanding sign shall have a white background.
ATTACHMENT A Seminole North Comprehensive Sign Proposal, page 1.
SIGN DETAK - - '.i n ED — AFWrJbfD W,REMSONS RESUBMIT X
NORTHWEST ELEVATION, VISIBLE FROM ROUTE 24
PHOTO ABOVE
CORRESPONDS
TO THIS AREA
ON MAP.
EXISTING SIGN
FOR TENANT;
BUILDERS
FIRSTSOURCE
IN
ATTACHMENT A Seminole North
NORTHWE5T ELEVATION, V!51BLE FROM ROUTE 29
PHOTO ABOVE
CORRE5P0ND5
TO TH15 AREA
ON MAP.
2.
EXI5TING SIGN
FOR TENANT
ROBERT5 HOME
MEDICAL
ATTACHMENT A Seminole North Comprehensive Sign Proposal, page 3.
SIGN DETAIL ^�.� '— A+Tf�7vFC APM0*D WRtf"W _ WSLew ]L
NORTHWE5T ELEVATION, V151BLE FROM ROUTE 29
YKUrU5tD 5IGN [SAND
PHOTO ABOVE
CORRE5POND5
70 TH15 AREA
ON MAP.
LX15TING 51GN
'OR TENANT: CfTY ELECTRIC 5UPPLY
EX15TING 51GN
FOR TENANT: UILLE CLA551C CAR5
12
ATTACHMENT A Seminole North Comprehensive Sign Proposal, page 4.
Nor —
SIGN DETAIL f�� APPROVED APP70vED WREV*IONS ` ;�ESLBNW - — -
S
NORTHWE5T E-EVATION, V15113LE FROM ROUTE 29
13
ATTACHMENT A Seminole North Comprehensive Sign Proposal, sign band locations, page 5.
SIGN DETAIL
PHOTO ABOVE
CORRf5PON05
TO TH15 AREA
ON MAP.
APPROVED ,� APPROVED WIREMSIOM i_, RESUBMIT ..
PR0P05ED 51GN SAND
14
ATTACHMENT B Wall signs approved for ABC Supply Co., page 1.
A
292" BUMP OUT SECTION OF TENANT FRONTAGE
ON
N
Cf\
_ m� 'Row
Supply Co. inc.
,.Vmy— u..+,wmvn u— L
O 36"H x 112.25"W x 3"D INDIVIDUAL NON -ILLUMINATED REV. CHANNEL LETTERS SQ FT: 2b
- .080 ALUMINUM LETTER RETURNS
- .090 ALUMINUM FACES PAINTED PMS x280 BLUE, PMS #186 RED, PMS WHITE
STUD FLUSH MOUNTED TO CORRUGATED ALUMINUM SIDING
12 H x 95 W x 6MM D NON -ILLUMINATING WHITE ECONOLITE PANEL W/ 8"H VINYL LETTERS SQ FT:
0
- 8"H % 76"W VINYL LETTERS.
- 6MM WHITE ECONOLITE NON -ILLUMINATED PANEL
- STUD FLUSH MOUNTED TO CORRUGATED ALLUMINUM SIDING
40"H x 96"W x 40" PROJECTION x 8"SIGN PANEL SHED AWNING W/ COMPANY LOGO SO FT: 4 r
O
IOGO: 15"H x 34"W . sq It 3.5 SHOWROOM:6"H x 34"W. sq ft: 1.4
- AWNING IS ALL ALLUMINUM, STAPLED- IN, WELDED FRAME; MILL FINISH
- SUNBRELLA FABRIC COLOR: BLUE; GRAPHICS COLOR: WHITE
Photo of installed signs
15
ATTACHMENT B Wall signs approved for ABC Supply Co., page 2.
a". IN VIA - 41•Y!
9 J I.7' 0YERAII LENGTH
m A INEW-
• §
D80 ALUMINUM
LETTER RETURNS
`i
_
090 ALUMINUM
FACES PAINTED COLORS '
AS NOTED
• § Supply COI inc.
I' TRCN YH)E ACRrUC DR WC
ama or Pw 0280LL
TO M=R11f1FACIE
MOULT ro WALL W SIC STUDS
A Sklcm ADHESIVE
An ANT F) I ISH TO WAI I W!
APPROPRUTE NCII4=00M
I I
TYPE HARDWARE FOR
WALL MATERIAL
I
■ PUS #2W BLUE
CORRt1GA7ED ALLIM110N1Mi
® INDIVIDUAL NON ILLUMINATED REV CHAVNEL LETTER ELEVATION SOFT z39 TI
■ PMs „��D
EXTERIORV2' PLYWODV
One (1) set required - I"c
F48RCATW AAARIM.M REVERSE CHAINIE: LETTERS - 3' DEEP 09) ALUMMUM FACES PAMTEO BLUE 6 RED
❑ INIS *HITS
090 ALUWAI RE IL:ttiS MWIED 10 MAICH FACES AND W TUMS FUSH SIM MOUITED 10 CORWWID AL.USNM WMG
END VIEW
O WHITE NON -ILLUMINATING ALUMICORE PANEL VINYL 1ST SURFACE
so FT 7 9
One 11) set required
tW'E Au/19CEpl'F+t+f. hANILA PMS OW WPM I ST SWWA fU194 STUD M"TED TO COrR1GATED AtjW1PA SOW6
tir-M�J ��i�� ems'-•
� - � 7Wfw�Mr r�N0,10>r� �Irww�
OVf�MDOn r�♦1��r •,! 1►��O
FOM b of 4
16
ATTACHMENT C City Electric Supply Sign Proposal, page 1.
CITY ELECTRIC SUPPLY
SIGN A 18' City Electric Supply
Channel shapes w/ remote transformers
and Illuminated tagbne cabinet
Intemally Illuminated LED
98.70
Top of sign to grade = 17.8 IR'
Bottom of sign to grade = 7'-11 1/4'
SIGN B Cdy Electne Supply
Applied vinyl on existing aluminum panel
271f2' x 41 112'
7.93
Charlottesville VA
17
ATTACHMENT C City Electric Supply Sign Proposal, page 2.
SIGN A 18- City Elscinc Supply
fftC;hsnnel shapes W remote transformers
Illuminated tagline cabinet
rnally Illum4nated LED
0
of sign to grade - 12'-B 172'
om of sign to grade = T-11 114'
W-O' Leads Dimension
20.8114-
CITY ELECTRIC SUPPLY
Front Elevation (North)
Scale 3116" = 1'-0'
Client. City Elednc Supply
Site IF C3-A22225 _
cnreiecrafcsurvLr Address. 4257Seminole Trae.S.A.0
Charlottesville. VA 22911
Existing
Q1 N
USA Icon - NO LF1ys
—ebOpeguef non-BAmM
Allowable Square Footage this Elevation:
Actual Sgwre Footage this Elevation
sy.,,
nnwn.n ::
18
ATTACHMENT C City Electric Supply Sign Proposal, page 3.
T-2'
13'a 119"
Sign Layout Detail
Scab: 172' = V-0'
Regrstrat!on mark VA* white acrylic W black vinyl (pin mounted)
r : SIGN A 1 15- City Electric Supply
ChanslDirmiers
White LEDs and Illuminated to f i � �
W 60w Transformer .85 amps each Yrmte lexan Red paint Genesis G2-6247"0•C (PMS 2000)a ne cabinet
Total Amps 2.55
(1) 20 amp 120V Circuit Req. Vl torso
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
11 Grounded and bonded per NEC 600JINEC 250 1
2) Existing branch circutl in compliance with
NEC 600.5. not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect swAch per NEC 600.6- required per
sign component before leaving manulachaer'
'For muft0e signs, a disconnect is permitted but
not required for each section
Black (gloss) paint Sabn charcoal grey paint (Ahto Nobel) Internally Illumnaled LED
JFull d"Ity printed graphics col dear oyerlaminate 96.70
Top of sign to grade = 17-8 1y2'
Bottom of sign to grade = 7'•11 1l4'
Specifications: Channel Shapes and Illuminated tagline cabinet 0
Existing Facade. Aluminum siding f Drywall 1 Metal studs
.040 Aluminum letter returns painted to match black
1• Fabncated aluminum retainers panted corporate red for the faces of'C1ES- and black for remainder. Note. the
'C'and'E• boxes are connected to the'Flag' as one shape col plat aluminum face tam (painted black) of junction
.080' aluminum backs stapled to returns- Seal wr VOC compliant 360 while latex caulk to prevent
mo sture penetration. (eitenor of sign can ptd white for max illumination) �l
White LEDs Go
Flogscape - V16' white lexan fares w applied digital print and laminate (Colors per spec chart)
Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600.6
Primary electrical feed in UL conduit 1 customer supplied UL junction box
Transformers within UL enclosure (removable hd), 1/4' x V min screws
318- Ttau Bolts w! 1 5'8- x 1 518' 12 gauge UN -Strut backer
2' Brake -formed cabinet painted Macy Rowel aluminum face wf 1r2• dear acrylic push-t hru copy- lauminated wr whit
The level of illuminated provides
by the LED lights will not exceed
the illumination produced by a
single stroke of 30 milliamp (ma)
neon.
Mir
O ICII
I -
Y: Drait M jt
Odbrndk4let lercans — )�: J4d►•
Section Cad Channel Letters
eLEDs(top 'bothorn)
Front -lit (Remote)
19
ATTACHMENT C City Electric Supply Sign Proposal, page 4.
SKiN B city Electric Supply
Applied vinyl on existing aluminum panel
27 1/Y x 41 i12'
7.90
Cnip7 Sneeificatinne-
while MM
■ eiadc (*a) panl
■ Red paint Gads G2F2079-00-C {PMS 2000i
■ Satn cf-mm psy pent (Alan Now)
Full dyihly phgeo yraphlcs wt clear a+eriaminale
ABC
<11T
O
%PRQBUiIr ��i
® w4wfr co A+e'
CITY ELECTRIC SUPPLY I
`mod ULASWG
r� (&M)973 SS71
New Replacement Panel - Existing D/F Pylon _ —
QTY 2 (1 SET) scale. t' = 1•-0' � -AA
_
1 • Existing aluminum panel
2. Applied vinyl per specification chart
20
ATTACHMENT D April 6, 2017 letter outlining review comments on the City Electric Supply Sign proposal.
us ^�
-'n T
COL-VTV OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottervtlle, Virginia 22902. 15%
Phone (4M) 296-5832 Fat WtO 9'2. 4126
April 6, 2017
Callie Robertson
Anchor Sign
2200 Dicher Avenue
Charleston. SC 29405
RE: ARD-2017-24 and ARB-2017-29: City Eleebic Supply Signs
Dear Callic,
l have reviewed the above -noted sign applications. The fuliowmg revisions arc requested to make the
proposal consistent with the Entrance Corridor Sign. Guidelines.
Fq- thr ttccstanding sieit:
The approved shade of red for tenant panels in the freestanding sign is Pantone 186C. The
approved blue colon: arc Pantone 301C and Pantone 280c. Please revise the drawing to ,how
color identifications that are consistent with these approved colors.
For the welLsiBn
2. Indicate on the drawing a Pantone number for the blue color.
3 Although the sign is centered over an entrance, it appears unbalanced because the C-F-S letters
and flagscape arc much heavier in appearance then the tagline. An alternate arrangement is
required.
a. The top of the C letter appears too close to the "cornice" of the Wilding. Additional clear space is
needed to avoid an overcrowded appearance.
5. This proposal is the second wail sign for this building. .As a multi-tetiant building, a
comprehensive sign plan is required and should be submitted at this time for review. Note that
Comprehensive Sign. Plana require coordination in sign type, size, placement, illumination, and
color across the building, and only the color and illunination of the proposed sign are consistent
with the existing ABC sign. Comprehensive Sign Plans require notion by the Architecture]
Review Board A sample Comprehensive Sign Plan is attached.
6 fhe $129 Entrunce Corridor sign fee was not paid Please suMnit payment so that review of your
application may continue.
Please respond by email within 15 days of ilie date of this letter indicating whether you will or w ill not
proceed w ith these revisions. Your decision to make the revisions will suspend the 60-day resicw period
associated with your original submtnal. If you choose to complete the re. isions, please email the revised
drawings to one. if yuu choose not in proceed with these revisions. staff will be unable In approve your
application. Failure to respond to the letter shall be presumed to be a request to proceed to action on the
application without further revisions.
ll'you have any questions about this action, please contact me as soon as possible.
'Sincerely.
_
Margaret Nlaliszewski
Chief of PlanninglResource Management
cc: ARB-201 i 24 and ARB-2017-29
Seminole Korth LLC, 1180 Seminole Trail. Suite 105, Charlottesville VA 22901
21
ATTACHMENT E Cville Classic Cars sign proposal, page 1.
L J APMXMD L ArraawFn w, M"S _i r+Esua W x
TAX MAP & PARCEL ID: 03200-00-00-005BO ZONING: LIGHT INDUSTRY
ALBMARLE COUNTY CODE: ALLOWED 1.5 SQ. FT. PER LINEAR FOOT OF BUILDING FRONTAGE
LOCATION: 4257 Seminole Trail, Suite C
Charlottesville, Va 22911
' IIN�L'b
(X1) SETS OF CHANNEL LETTERS
LETTER SPECIFICATIONS:
SIGNTYPE:
CHANNEL LETTERS
All welded channel letters with
single row white led illumination
BACKS .063 ALUM.. S" RETURN,
RETURNS .0a0 ACRYLIC 3/16"; PAINTED FINISH
UL LED, 1 EVERYLITE LED TRANS
FLUSH MOUNT
- ILLUMINATED
WILL NOT EXCEED THE
ILLUMINATION PRODUCED BY
A SINGLE STROKE OF 30 MILL IAMP
(MA) NEON
SIGN BAND DIMENSIONS:
SIGN BAND - 96"w x 39 5"h .26 3 SO F1
SIGN TO FIT WITHIN EXISTING SIGN BAND AREA
108' BUILDING FRONTAGE
SIGN HEIGHT -BOTTOM OF SIGN 118" ABOVE FINISHED GRADE
TOP OF SIGN- 157.5'ABOVE FINISHED GRADE
4n4�nn4ilnm � -
1�-K�rta 4itri
xAalw MT�Mn
UDwanr,•.
♦f 4QIi4�
� auw ex
lwr1EwP fsl)" f
NIGHT ILLUMINATION
•
r
MATERIAL FINISH COLORS:
■ PMS 280C - Acrylic Face (Logo)
PMS WHITE - Trim Cap, Returns
DAYLIGHT
___I
4 ANN
22
ATTACHMENT E Cville Classic Cars sign proposal, page 2.
TAX MAP & PARCEL ID: ' 100-00-00-005B0 ZONING: LIGHT INDUSTRY
ALBMARLE COUNTY CODE: ALLOWED 1.5 SQ. FT. PER LINEAR FOOT OF BUILDING FRONTAGE
LOCATION: 1 rail, Suite C
Charlottesville, Va 22911 38.00 to
EXISTING FREESTANDING SIGN A
(x2) Vinyl Applique
- 38"w x 15.75"h
- Applied to both sides of
to
existing aluminum panel t`
L1�
MATERIAL COLORS:
■ Sapphire Blue (Pantone 280C) Vinyl Applique
Side 1 Side 2
23
ATTACHMENT F Freestanding sign refacing approved with ARB-2016-17.
.tit txrna
Q
W
0
un�cn:o wow!.. � wn �ryonx a�.tMt N
132"(OVERALL LENGTH)
66" (PANEL WIDTH)
T
W
__ J_mrVm,
W
,
t.
q
PROBUIld
Supply Co. inc.
LEASING
(434) 973-5571
(2x) SET 60"H x 132"W x 1 /-C" TH - SINGLE•SIDED ALUMICORE PANELS TOTAL : 55 SOFT.
Vw SIGN SPECIFICATIONS: SCALE: PROPORTIONAL
,',':ALL; ! 0 UL M1L\I)L IN 30"H a 66 W SECTIONS AS SHOWN I IHERE WILL BE VISIBLE SEAMING?
PANEL S TO BE ADHERED TO EXISTING CORE % PANELS ALREADY INSTALLED TO SIGN ( THERE MAY BE SOME RIPPLINGI
ANELS TO BE MADE IN 30-H ■ 44'W SECTIONS A SHOWN I THERE WILL BE VISIBLE SEAMING)
44"{PANEL WIDTH)
MATERIAL FINISH COLORS:AOC SUPPLY
VMS 260C m PMS 186C
komwn Cut Vmy1 i'trnWm Cut V.nyl
MATERIAL FINISH COLORS: LEASING
PMS 301C N PMS BLACK
P. iro Cut-Vryl Prenrarn CAN Vinyl
The k4--- 0 - criteria slaaa apoy to all tenant panels oA We sign structure
AE twum panel eactyrumrd wb "be ttAtd w1i�LIIIIIIIIIIIIIIN
Per-trettrd tram pine oa4 adrr [mr�%ee, F11FSs3:t. 3ro+.r PYtS •4" ohm Pets «301 due PrS Vzw-Res PSRS o1wA PwS8hmd PUS 34K IN PILE4W
wt�OaMwt p+'�re6R�lM
ut... 0cm0 x ttt
tr.�e-� ►sea eater a�� •stx. a�ftta�etac- . yca..e
ew�►�-----@WON&lrra-r.- I
24
ATTACHMENT G Photo of freestanding sign, January, 2018.
25