HomeMy WebLinkAboutSP201700010 Resubmittal Special Use Permit 2017-10-16LEGEND
W
WATER LINE
UGC
UNDERGROUND COMMUNICATIONS (EX.)
WV 0 WM 0
WATER VALVE / METER
— OHE + OHC —
OVERHEAD ELECTRIC AND COMMUNICATIONS (EX.)
FHA (�
FIRE HYDRANT
OHC
OVERHEAD COMMUNICATIONS (EX.)
YH -&
YARD HYDRANT
BOUNDARY / RIGHT-OF-WAY LINE
BOA 0
BLOW -OFF ASSEMBLY
IF
IRON FOUND
S
SANITARY SEWER LINE (EX.)
BPF
BENT PIPE FOUND
CO 0
CLEANOUT
IPF
IRON PIPE FOUND
SSMH 00
SEWER MANHOLE
SETBACK LINE
— —
EXISTING STORM DRAIN LINE
—
EASEMENT LIMITS
—sn sn—SD—
PROPOSED STORM DRAIN LINE
—
CENTERLINE
DI ❑
DROP INLET
---�
CONTOUR LINE (EX. / PROP.)
SDMH 0
STORM DRAIN MANHOLE
3:1— E-2.50%—
DEGREE / DIRECTION OF SLOPE
FD 0
FLOOR DRAIN
+479.70
SPOT ELEVATION
G
GAS LINE (EXISTING)
HP
HIGH POINT
GV® GM O
GAS VALVE / METER
LP
LOW POINIT
UP0
UTILITY POLE
■—■ -W
DITCH W17H LINING
LP-0
LIGHT POLE
—''
DITCH / SVNALE
GUY d
GUY WIRE
WATER CC7URSE
EM a
ELECTRIC METER
BM*
BENCHMARK
MB n
MAILBOX
CMP
CORRUGATED METAL PIPE
m
TRANSFORMER
PVC
POLYVINYLCHLORIDE PIPE
PED 0
UTILITY PEDESTAL
FEE
FINISHED FLOOR ELEVATION
OHE
OVERHEAD ELECTRIC (EX.)
FES
FLARED END SECTION
LINE TABLE
LINE
LENGTH
BEARING
L1
15.93'
S85°52'08"W
L2
26.63'
S03°50'36"E
L3
17.80'
N89°58'23"E
L4
17.16
N51'52'11"E
IZ:;,vviw 14" WILD I_I-I — Z
CHERRY 10" & 10" CHERRY INE LF1I 0
DBL WILD
. CHERRY
O r 16" WILD
UR
'
TO
453
37
SURVEY & TOPOGRAPHY
1.
TOPOGRAPHIC SURVEY PREPARED BY TERRA ENGINEERING AND LAND
SOLUTIONS; PC, CHARLOTTESVILLE, VIRGINIA, JULY 8, 2008.
2.
BASE MAP IS A COMPILATION OF A PREVIOUS TOPOGRAPHIC SURVEY BY
OTHERS, A PARTIAL NEW TOPOGRAPHIC SURVEY BY TERRA ENGINEERING AND
LAND SOLUTIONS, PC AND ALBEMARLE COUNTY GIS MAPPING.
3.
THE ELEVATION DATUM IS THE SAME USED FOR BELVEDERE BOULEVARD
CONSTRUCTION. OLD BENCHMARK WAS DESTROYED BY CONSTRUCTION OF RIO
ROAD AND WILL BE RESET FOR FINAL SITE PLAN.
WV 4.
THE MERIDIAN IS BASED ON BEARING OF LINE ALONG NORFOLK SOUTHERN
RAILWAY AS SHOWN ON PLAT RECORDED IN DEED BOOK 535 PAGE 402.
5.
CONTOUR INTERVAL PROVIDED BY TERRA ENGINEERING AND LAND SOLUTIONS,
PC IS 2 FOOT.
6.
THIS PLAN DOES NOT GUARANTEE THE EXISTENCE OR NON-EXISTENCE OF
UNDERGROUND UTILITIES. PRIOR TO ANY CONSTRUCTION OR EXCAVATION, THE
CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OF, OR THE
NON-EXISTENCE OF, UNDERGROUND UTILITIES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR NOTIFYING "MISS UTILITY" (1-800-552-7001).
7.
NO TITLE REPORT FURNISHED. OTHER EASEMENTS, ETC. MAY AFFECT
oonocory
BRICKCOLUMNS 11
z
(L
z
w
I�re
Z
® O
Wi
Cfr)
�r
co -
SCALE.
ISSUE
DRAWN:
DESIGN:
CHECKED:
REVISIONS:
1 7-28-17
2 10-16-17
;AS NI O ' i
4/17/2017
A,
SLD
COUNTY COMMENTS
COUNTY COMMENTS
All sights rerved. N- part wf tha material lirotectesl by this copyright
,(plams, ideas, designs, sectio,as or details cxped ova tliest plaaas) may be
reprod—cl, changed or wilizcd in any Tc rm or by amp mneans, eflcctrotuic or
mcchanaical, inclmdh,g photucoipyimg, scaamtimg, or by amy o1he, tmeal olf
retrieval systei without written pern issiun f o i, 'e Engim ring and
Land S.hakioms, PC.
Al-, these puns m y not be assig-1 to a third party without ffitst .vritte
avtho,iza'tiaam cff "ff'etca ff?atginccring grad Land uu4ntioms, PC.
tDTEIUll A rNGINI?LIUNG AND LAND SOLU rIONS, PC
SHEET
_L
ci 40
J.N� 1705 1 OF 3
VICINITY MAP
SCALE: 1" = 2000'
BUILDING ELEVATION NOTE:
Building elevations visible from Rio Road shall not be blank walls. Instead, building
elevations shall incorporate at least two of the following types of elements:
fenestration, architectural detailing with a minimum projection of 6 inches, or
recesses/projections in the building wall with a minimum depth of 18 inches.
These features shall be distributed across the entire elevation. Compliance with
this condition shall be determined by the Director of Planning or designee prior to
approval of the church's final site plan.
GRAPHIC SCALE
40 0 20 40 80
( IN FEET)
1 inch = 40 ft.
WIL
CONNECTION'
(.SAT E U
/
/
co
�— ACSA CONNECTION MH
EXISTING OFFSITE SEWER CONNECTION
(NTS)
SGRE:EN
HE,G
9
10 ``
SITE DATA,
BUILDING AREA:
21,450 S.F. +/-
y N
N� o. _
�j° EXIT ONLY
BUILDING HEIGHT:
30' +/-
`2�
REGULAR PARKING SPACES:
194
4 '*�
HANDICAP SPACES:
5
VAN SPACES:
1
1 0 SHADE TREE ,..:
TOTAL PARKING SPACES:
200
(TYP. x20)
10
� y
, 1
✓✓
LEGEND
—W
WATEIR LINE
UGC
UNDERGROUND COMMUNICATIONS (EX.)
WV¢& WM O
WATEIR VALVE / METER
— OHE + OHC —
OVERHEAD ELECTRIC AND COMMUNICATIONS (EX.)
FHA {}
FIRE HYDRANT
OHC
OVERHEAD COMMUNICATIONS (EX.)
YH (�}
YARD HYDRANT
BOUNDARY / RIGHT-OF-WAY LINE
NOTES:
BOA G
BLOWI-OFF ASSEMBLY
IF
IRON FOUND
1. For the two sides of the building that will face Rio Road, features such as
BPF
BENT PIPE FOUND
windows, doors, and/or changes in plane to the building faces will be
SANITARY SEWER LINE (EX.)
provided in accordance to the neighborhood model principle for buildings
CO
COO
CLEAPVOUT
IPF
IRON PIPE FOUND
and spaces of human scale.
SSMH 0
SEWE R MANHOLE
SETBACK LINE
— -- � —
EXISTIING STORM DRAIN LINE
—
EASEMENT LIMITS
2. The egress only entrance onto Rio Road East is subject to approval of an
_Sp_SoSD—
PROPOSED STORM DRAIN LINE
—
CENTERLINE
Access Management Exception by VDOT.
DI F-1
DROP INLET
CONTOUR LINE (EX. / PROP.)
* Permanent utility easement for dominion virginia power, central telephone
SDMH O
STORIM DRAIN MANHOLE
3:1— F2.50%—
DEGREE / DIRECTION OF SLOPE
company of virginia and n-telos
FD O
FLOOR DRAIN
+ 479.70
SPOT ELEVATION
—G
GAS LINE (EXISTING)
HP
HIGH POINT
GV® GM O
GAS VALVE / METER
LP
LOW POINT
TRAFFIC:—�
uP�
UTILITY POLE
-�—�
DITCH WITH LINING
Parking space requirement per section 4.12 of the zoning ordinance 1 space
;- -
DITCH / SWALE
per 3 fixed seats OR per 75 s.f. whichever is greater
LP
LIGHT POLE
GUY d
GUY WIRE
WATER COURSE
1160
500 seats 13 = 167 spaces OR
EM o
ELECTRIC METER
BM+
BENCHMARK
■
15,000 s.f. / 75 = 200 spaces
p
CMP
CORRUGATED METAL PIPE
J
MB o
MAILBOX
TRANSFORMER
PVC
POLYVINYLCHLORIDE PIPE
PED ❑
UTILITY PEDESTAL
FFE
FINISHED FLOOR ELEVATION
—OHE
OVERHEAD ELECTRIC (EX.)
FES
FLARED END SECTION
Z
CL
Ui
o
Z
Ga
ZQ
Z
4i
Cn
(i 4
SCALE-
ISSUE D.
DESIGN:
CHECKED:
1 7-28-17
2 10-16-17
ASNOTED
04 /17/2017
d E
COUNTY COMMENTS
COUNTY COMMENTS
rAil riglaks reeerqea. Yo Mari of ilne aaaakerial garoTea;ted b} t}ais sopyrigpak
fj1>Itaras� icl+;as, aesigns, xskioaas ®r aetails espressecl oea t'he�e plans) naa3- �e
rel>ruan cca, cla:angcd or wkip iced iaa vaj- i'oxaaa ar by any cancans, eleskronic or
nnc cl�anical, hadnding ph.toeapyh g, scanning, am by any otiaer nasana of
rest riev al systeau iviklaatak tvritteaa l�eaanissian frorna "l'erra Esngiraccriarg ana
Lana Sal"kians, PC,
Al-, fliese plans may not be assigned to a third party without first wrMen
annpaori-tion of Terra Eagh,a ing :and 1anri Salukions, PC.
�9 TERRA EP;CINEERING AF:?D LAND SOLI Tp'IDNS, PC.
SHEET
J.N.0 /71
4()U
1705 2 OF 3
5'9
5'
5(
4�
4s
4',
4(
4!
4�
4;
4,
4'
51
5'I
5(
44
4�
4,
4(
4'
42
4:
4,
4
SCALE: V = 20'
SECTION 2 PROFILE
SCALE: V = 20'
z
w
z
0
w
za
z
At
Q
z
r
ram- �+
:,,:,,
e
%
b
L
SCALE. -
ISSUED:
DESIGN -
CHECKED:
All rights t--ed. No part of the sn.aterial protected by This copyright
(plaDs, ideas, designs, sections or dlel:nils expressed on these plans) may be
reprodwced, changed or wtilised in any dorm or by any means, electronic -
nstchanioal, including pinctoccpying, scanning, or by any other uneans of
rclrity al systtnn , itlnout ♦vrilne❑ p-mksian t'ronn Terra Engineering and
Laud Bulutions. PCB.
Also, then plans may anent be assig—.a to a third party v,ith—t fast my itten
audiurizali2 n of Terri Eangineeiring and Laud Solutions, PC.
0TERRA ENGINEERING A. -ND LAND SOLUTIONS, PC
SHEET
C3
1
a
J.N. 1705 3 OF 3