HomeMy WebLinkAboutARB201700015 Checklist 2018-03-01Provide for review large EIFS sample panels including reveals.
� Provide manufacturers information on the colorfastness of the EIFS material in the colors proposed.
7` Gcl'L t rir��
V' • Revise the Nichiha "brick" panel to brick that matches Gander Mountain (Old Virginia Brick Poplar Forest).
\ Revise the bright white stone for the retail building to an off-white shade that coordinates better with the other
V building colors.
Provide the Lymstone Gray anGr Fre:edomay2lor samples for review.
Vc/:i,,¢.. GIA
! �' 1Md•11• �+...1� V�.�'.is...,�. �-,-- �—�•y�, 8%t�J'f✓�'�'�..�J dj�'� r1' t..J
V� Revise the north elevation of the Buffalo wild Wings building to increase the architectural detailing and reduce the
amount of yellow EIFS. A reduction of 2/3 as suggested by applicant is reasonable.
J ��� G r *6
-f I 1 �
— Ur-�.f.E z v~l• r.. y , . c ., f r> } .. -. i CAA -
Vie, -,Indicate Building 1 as future development.
44
V8. Include the standard window glass note on the architectural drawings and provide a glass sample(s) and specs for
review.
�� o
Provide a rb6f plan an elevatio bowing rooftop equipment locations and sizes. Ensure that equipment is not
visible from the EC.
' t
� ;i
�17'-)�1-7
l/ 1. The photometric plan shows spillover in excess of .5 fc on the eastern property line. This appears
to be an error in/the
—calculations because no
no light pole is nearby. Please correct the plan.
Because the linear fluourescent fixture is not a full cutoff fixture, it must emit less than 3000
lumens. Please clearly note on the lighting plan the number of lumens emitted by this fixture.
4-L44 c 41'" 7) 4'>�l 4
Sheet A301 shows uplights and LED fixtures that are not shown on the other lighting plans. Provide
for review complete information on these fixtures on sheets 7-9 of the site plan. However, note that
the uplights may not be approvable.
Most of the light symbols shown at the buildings on sheet A7 are not legible. Indicate what the six
groups of four fixtures are at the retail building and the two
AM fixtures at the entrance to the
BWW building. 4,1.' „/ to / t'&�
r"
LiuriTING PLAN REVIEW CHECKLAa I
CHECKLIST ITEM NOTES
Cut sheets
P Lumen level (3000 or more must be full
cutoff)
I Bulb/lamp location(must be totally within A. 2S h,. � .c�� _ is "�s-s,. 3mi L.
v" house to be full cutoff)
Luminaire schedule
cr____..c- - ""Catalog# coordinated with cut sheets Ctsci il. rrw'c/ •trtet.- eav-r ^,-4
�,/,�) Fixture quantity/types coordinated with <Mai to Ludo
r�� quantity/types on lighting plan
✓❑ Pole height/mounting height(ARB) 02 J 1
1711 Colors/finishes (ARB) pcW o'!, >•%a Ga
c o c1 ks� '/ G.,, oundri.to
❑ Tilt(must be 0 for full cutoff) tra is TLi -&
Fixture locations jl Location conflicts with trees, utilities, etc. Grld--geo `t�
czi rev ,
Coordination with other site plan sheets •
Shielding issues (freestanding signs, wall .1
fixtures, etc.)
Photometric plan
Adjacent zoning
t.ar Property lines V
3 Excessive spillover —,...-_.
C
Y✓° Excessive lighting levels (ARB) ¢6 bthc /jiur4f4), Alb
V Maintenance factor= 1.0 J D
ire Standard lighting notes: Each outdoor
luminaire equipped with a lamp that emits 3,000 or �l-
more initial lumens shall be afull cutoff luminaire Gcr' e , / ,
and shall be arranged or shielded to reflect light
away from adjoining residential districts and away
from adjacent roads. The spillover of lighting from
luminaires onto public roads and property in
residential or rural areas zoning districts shall not
exceed one-halffootcandle.
7
Utlai, Cie L4-'121 I W f—.