Loading...
HomeMy WebLinkAboutWPO201700076 Plan - Submittal (First) 2018-03-15E C Ll 0 1 1 2 1 3 1 4 1 5 1 6 DRAWING INDEX GENERAL T1.01 CIVIL C2.01 C2.03 C3.01 C3.02 C4.01 C4.02 C7.01 C7.02 C8.01 - C8.02 C8.03 - C8.04 C8.05 C8.06 C9.01 C9.02 C9.03 C9.04 C9.05 C9.06 C9.07 C9.08 C9.08A C9.09 C9.10 C9.11 C10.01 C11.01 COVER SHEET GENERAL NOTES SOILS MAP DEMOLITION PLAN DEMOLITION PLAN ROADWAY PLAN - STA. 10+00 TO 16+25 ROADWAY PLAN - STA. 16+25 TO 22+00 GRADING AND DRAINAGE PLAN GRADING AND DRAINAGE PLAN EROSION AND SEDIMENT CONTROL PLAN - PHASE I EROSION AND SEDIMENT CONTROL PLAN - PHASE II EROSION AND SEDIMENT CONTROL NOTES EROSION AND SEDIMENT CONTROL DETAILS SWM NARRATIVE AND CALCULATIONS PRE AND POST DEVELOPMENT LAND USE MAPS WATER QUALITY NARRATIVE AND CALCULATIONS CHANNEL PROTECTION MAPS & CALCULATIONS CHANNEL PROTECTION ROUTINGS FLOOD PROTECTION MAPS FLOOD PROTECTION CALCULATIONS & ROUTINGS STORMSEWER MAPS AND CALCULATIONS STORMSEWER PROFILES DITCH MAPS AND CALCULATIONS CULVERT MAPS AND CALCULATIONS DETENTION BASIN DETAILS CONSTRUCTION DETAILS LANDSCAPING PROJECT ZONING DATA ALBEMARLE COUNTY ZONING CLASSIFICATION: R-1 RESIDENTIAL PROPOSED BUILDING MAXIMUM HEIGHT: N/A PROPOSED BUILDING MAXIMUM FOOTPRINT: N/A ALBEMARLE COUNTY MAGISTERIAL DISTRICT: SAMUEL MILLER DISTRICT FEMA FLOOD INSURANCE RATE MAP: ZONE X; NOT WITHIN A FEMA DEFINED 100 YEAR FLOOD PLAIN PROPERTY NOT WITHIN AN ALBEMARLE COUNTY AND / OR CITY OF CHARLOTTESVILLE WATER SUPPLY WATERSHED CODES VDOT ROAD AND BRIDGE STANDARDS, 2016 VDOT ROAD AND BRIDGE SPECIFICATIONS, 2016 FEDERAL HIGHWAY ADMINISTRATION MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, 2009 VIRGINIA SUPPLEMENT TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, 2013 VIRGINIA WORK AREA PROTECTION MANUAL, REV. 1A, 2015 DEPARTMENT OF ENVIRONMENTLA QUALITY VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK - 1992 ADA STANDARDS, 2010 CONTACTS OWNER: University of Virginia Foundation OWNER REPRESENTATIVE: Christopher D. Schooley Real Estate Project Manager One Boars Head Pointe Charlottesville, VA 22903 PH: (434) 982-3777 cds7@eservices.virginia.edu ENGINEER: Dewberry Engineers Inc. ENGINEER REPRESENTATIVE: Matthew C. Thomas, PE Project Manager 4805 Lake Brook Drive, Suite 200 Glen Allen, VA 23060 PH: (804) 205-3340 mthomas@dewberry.com SUBMITTAL SET NUMBER PRELIMINARY CONSTRUCTION APPROVAL REVISION BIDDING RECORD UNIVERSITY OF VIRGINIA FOUNDATION TEMPORARY GOLF COURSE CONNECTOR ROAD FROM: GOLF COURSE DRIVE TO: BERWICK DRIVE ALBEMARLE COUNTY, VA LOCATION MAP VSMP PLAN - WP0201700076 0 SCALE 1" = 250' n O aQ rn 29 250 IVY RD e ° . e e e e ee e i► r °. 4 ®ee r^/ BOARS HEAD INN sl VICINITY MAP SCALE 1" = 100' 250 OBDVy RD Fal Dewberry Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) 0 Q oo O �w0 �LLI a � U) U) �O UU) 00 vv �2 Ov~ LLQ ZD LL LU J� Ou J W OOw UO LU 0z m o0 Z 20 o O o� o c LL A SEAL op'l; LTIf QAC r WEW Lic. No, 465 Vol ALES SCALE SCALE: 1" = 250' 0 250' 500' No. I DATE I BY I Descrlpllon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rior to an construction within an existing public right-of-way,includin connection to an existing road a Y Y 9 P 9 Y 9 permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. 4. All slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. 6. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer, or designee, it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. 8. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe ? Class III. 9. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). ALBEMARLE COUNTY GENERAL CONSTRUCTION NOTES FOR PRIVATE ROADS 2. 3. 4 61 1. TREES AND VEGETATION ADJACENT TO THE ACTUAL WORK AREA OR BORROW AREA ARE TO BE PROTECTED WITH TEMPORARY FENCING (CHAIN LINK FENCE FOR TREES; CONSTRUCTION SAFETY FENCE FOR VEGETATION) TO PRESERVE EXISTING ITEMS INDICATED TO REMAIN AND TO PREVENT DAMAGE TO PROPERTY. 6. 2. UNDERGROUND UTILITIES SHALL BE LOCATED SO THAT CONSTRUCTION WILL NOT DAMAGE OR DESTROY THE PLANTS TO REMAIN. UTILITY TRENCHING SHALL NOT BE LOCATED CLOSER THAN 1'-0" FOR EACH 1" IN DIAMETER UP TO A MAXIMUM OF 20'-0" 7. FOR TREES TO REMAIN. DAMAGED TREES AND PLANTS SHALL BE RESTORED TO THE SATISFACTION OF THE UNIVERSITY. 3. THE PARKING OF VEHICLES AND STORAGE OF ANY CONSTRUCTION EQUIPMENT OR MATERIALS SHALL NOT OCCUR UNDER THE DRIP LINE OF TREES TO BE PROTECTED. 8. GENERAL DEMOLITION NOTES 1. SAW CUT AND REMOVE ALL ASPHALT AND CONCRETE TO LIMITS REQUIRED FOR PROPOSED WORK. 9. 2. REMOVE VEGETATION, GRASS, & ROOTMAT IN AREAS TO RECEIVE NEW ASPHALT AND CONCRETE PAVEMENTS. 10. 3. ALL PRIMARY UTILITIES DISCOVERED DURING DEMOLITION OPERATIONS THAT SERVE OTHER ACTIVITIES SHALL BE PROPERLY IT. PRESERVED AND PROTECTED. 4. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER ANY UNFORESEEN OR ADVERSE CONDITIONS DISCOVERED DURING 12. DEMOLITION OPERATIONS. 5. CONTRACTOR SHALL PROTECT EXISTING PLANT MATERIAL NOT DESIGNATED FOR REMOVAL OR RELOCATION FROM DAMAGE DURING 13. CONSTRUCTION. 6. CONTRACTOR SHALL KEEP ALL SURROUNDING PUBLIC ROADWAYS AND DRAINAGE SYSTEMS FREE FROM DIRT, MUD, AND 14. CONSTRUCTION DEBRIS AT ALL TIMES. 7. LIMITS OF DEMOLITION INDICATED ON PLAN ARE MINIMUM. CONTRACTOR SHALL REMOVE ASPHALT PAVEMENT, CONCRETE AND MISCELLANEOUS ITEMS AS NECESSARY TO FACILITATE CONSTRUCTION IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. 15. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY ITEMS DAMAGED DURING THE CONSTRUCTION. 16. 9. CONTRACTOR IS RESPONSIBLE FOR STAGING THE DEMOLITION OF EXISTING UTILITIES WITH INSTALLATION OF NEW. OWNER SHALL BE GIVEN AMPLE WARNING PRIOR TO ANY DISCONTINUATION OF ANY SERVICE. Prior to any construction within any existing public right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. Construction inspection of all proposed roads within the development will be made by the County. The contractor must notify the Department of Engineering (296-5861) 48 hours in advance of the start of construction. All materials and construction methods shall conform to current specifications and standards of VDOT. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and must be installed prior to any clearing, grading or other construction. Upon completion of fine grading and preparation of the roadbed subgrade, the contractor shall have CBR tests performed on the subgrade soil. Three (3) copies of the test results shall be submitted to the County. If a subgrade soil CBR of 10 or greater is not obtainable, a revised pavement design shall be made by the design engineer and submitted with the test results for approval. All slopes and disturbed areas are to be fertilized, seeded and mulched. The maximum allowable slope is 2:1 (horizontal:verticol). Where reasonably obtainable, lesser slopes of 4:1 or better are to be achieved. Surface drainage and pipe discharge must be retained within the public right-of-way or within easements prior to acceptance by the County. All drainage outfall easements are to be extended to a boundary line or a natural watercourse. Guardrail locations are approximate. Exact length, location and appropriate end treatments will be field determined at the time of construction. Additional guardrail may be required at locations not shown when, in the opinion of the Director of Engineering, or the Director=s designee, it is deemed necessary. When guardrail is required, it shall be installed four (4) feet offset from the edge of pavement to the face of guardrail, and roadway shoulder widths shall be increased to seven (7) feet. Where urban cross sections are installed, all residential driveway entrances shall conform to VDOT CG -9(A, B or C). Where rural cross sections are installed, all residential driveway entrances shall conform to VDOT standard PE -1. Paved, rip -rap or stabilization mat lined ditch may be required to stabilize a drainage channel when, in the opinion of the Director of Engineering, or the Director=s designee, it is deemed necessary. A minimum clear zone of eight (8) feet from the edge of pavement shall be maintained on all residential subdivision streets. Compliance with the minimum pavement width, shoulder width and ditch sections, as shown on the typical pavement section detail, shall be strictly adhered to. Exceptions will not be allowed. Upon completion of the roadway construction, street name signs shall be installed by the developer at all street intersections. Signs and their installation shall conform to "Albemarle County Street Name Sign Requirements". The developer shall be responsible for maintenance of signs until roads have been accepted. Road plan approval is subject to final subdivision plat validation. Should the final plat for this project expire prior to signing and recordation, then approval of these plans shall be null and void. Traffic control or other regulatory signs or barricades shall be installed by the developer when, in the opinion of the Director of Engineering, or the Director -s designee, they are deemed necessary in order to provide safe and convenient access. All signs or other regulatory devices shall conform with the Virginia Manual for Uniform Traffic Control Devices. UGE EXISTING UNDERGROUND ELECTRICAL LINE OLE EXISTING OVERHEAD ELECTRICAL LINE G EXISTING GAS LINE SS EXISTING SANITARY LINE SD EXISTING STORM LINE UGT EXISTING TELEPHONE OLT EXISTING OVERHEAD TELEPHONE EXISTING TREEUNE UGW EXISTING WATERLINE - F2C EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING POWER POLE XMFR EXISTING ELECTRICAL GENERATOR 0 EXISTING SITE LIGHT X EXISTING WATER VALVE Dx) EXISTING STORM INLET J (Ex.1 SD EXISTING MANHOLE � EXISTING FIRE HYDRANT OW EXISTING WATER METER EXISTING FENCE EXISTING SIGN o j EXISTING TREE o EXISTING SANITARY CLEANOUT go.EXISTING STEEP SLOPES V DOORWAY ACCESS PROPOSED LIMITS OF DISTURBANCE HARDSCAPE TO BE DEMOLISHED TREE TO BE DEMOLISHED UTILITY/STRUCTURE TO BE DEMOLISHED SITE FEATURE TO BE DEMOLISHED 620 PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED STORM LINE ❑® q0 PROPOSED STORMSEWER STRUCTURE PROPOSED GATE DENOTES PROP. FULL DEPTH PAVEMENT DENOTES MILL & OVERLAY EXISTING PAVEMENT Dp DENOTES CONCRETE SIDEWALK d PROPOSED RETAINING/SEAT WALL PROPOSED CG -6 PROPOSED CG -2 ° 'Sen"� Dewberry__� Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) 0. Q 00 O LL]o �O Uc� Qpi 0�z 0�00 UU 1---W OvI�- U� U J3: z� J LLJ O w(.)0 O W0 Z (D U O �Z (DO� o O � U LL SEAL SCALE o��gALT1Y op O- TT EW Lic. No, 465 1 Ai.E�G� No. I DATE I BY I Descrlptlon 10 REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE GENERAL NOTES PROJECT NO. 50097555 C2.01 SHEET NO. OF C 41__t��Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J0�Ov JW 0UO WIZ m �oo 0 OO 0O c:) U r LL SEAL - O��gp►LT15Top TT EW �1G1 S Ap Lic. N0. 465 1 ,; Ai.E�G� C SCALE SCALE: V = 40' 0 40' 80' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE SOILS MAP PROJECT NO. 50097555 C2003 SHEET NO. OF 1 7 - d R R C 41__t��Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J0�Ov JW 0UO WIZ m �oo 0 OO 0O c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1" = 20' 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE DEMOLITION PLAN PROJECT NO. 50097555 C3001 SHEET NO. OF 1 7 - d R R �smegjjj 1W Dewberry C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O �w0 �Q � ��� 0�O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw O W0Z m Uo �o(DO OO c:) U r H SEAL ' O1'gALTIf DAG O + �r Ews Lic. No. 465 1 4� Ip ALES C SCALE SCALE: V = 20' 0 20' 40' IV L No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE DEMOLITION PLAN PROJECT NO. 50097555 C3002 SHEET NO. OF 1 7 - d R R 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O TWO UQ � ��� �O Uc) <�� 0� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WOZ m �oo 0 OO 0O c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1'' = 20' 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE ROADWAY PLAN STA. 10+00 TO STA. 16+25 PROJECT NO. 50097555 C4001 SHEET NO. OF 9 1 d R F �smegjjj 1W Dewberry Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C Fp C)ry Q pp O TWO �Q � U) C/) 0�O Uc) <�� 0� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W �O WOZ Owm U Op oo (DO 0O c:) U r H SEAL ' O1'$VALTR DAG O TT EW 1 S— Lic. No. 465 1 `�S Ip ALE�G� C SCALE SCALE: V = 20' 0 20' 40' IV L No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE ROADWAY PLAN STA. 16+25 TO STA. 22+00 PROJECT NO. 50097555 C4002 SHEET NO. OF 1 7 - d R R 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O TWO UQ � ��� �O Uc) <�� 0� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WOZ m �oo 0 OO 0O c:) U r LL SEAL o��gALT1Y °AG WEW S Lic. No. 465 1 C SCALE SCALE: 1" = 20' 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE GRADING & DRAINAGE P LAN STA. 10+00 TO STA. 16+25 PROJECT NO. 50097555 C7001 SHEET NO. OF 1 7 � d R R �smegjjj 1W Dewberry Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C Fp C)ry Q oo O �w0 �Q � ��� 0�O Uc) <�� 0� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw O WOZ m Uo �o(DO 0O c:) U r H SEAL ' 0'gALTIfop xo �r EW s Lic. No. 465Ak 1 ,� �j0 ALES C SCALE SCALE: V = 20' 0 20' 40' IV L No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE GRADING & DRAINAGE P LAN STA. 16+25 TO STA. 22+00 PROJECT NO. 50097555 C7002 SHEET NO. OF 1 7 - d R R 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WIZ m �oo 0 OO OO c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1'' = 20' 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE E&S CONTROL PLAN - PHASE 1 PROJECT NO. 50097555 C8001 SHEET NO. OF 1 7 - d R F �smegjjj 1W Dewberry C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O �w0 �Q � ��� 0�O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw O W0Z m Uo �o(DO OO c:) U r H SEAL ' O1'gALTIf DAG O + �r Ews Lic. No. 465 1 4� Ip ALES C SCALE SCALE 0 20' 40' IV L No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE E&S CONTROL PLAN - PHASE 1 PROJECT NO. 50097555 C8002 SHEET NO. OF 1 7 - d R R C 41__t��Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WIZ m �oo 0 OO OO c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1'' = 20' 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE E&S CONTROL PLAN - PHASE 2 PROJECT NO. 50097555 C8003 SHEET NO. OF 1 7 - d R R �smegjjj 1W Dewberry C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O �w0 �Q � ��� 0�O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw O W0Z m Uo �o(DO OO c:) U r H SEAL ' O1'gALTIf DAG O + �r Ews Lic. No. 465 1 4� Ip ALES C SCALE SCALE: V = 20' 0 20' 40' IV L No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE E&S CONTROL PLAN - PHASE 2 PROJECT NO. 50097555 C8004 SHEET NO. OF E �J C L1 W EROSION & SEDIMENT CONTROL NARRATIVE PROJECT DESCRIPTION THIS PROJECT INCLUDES ROADWAY CONSTRUCTION TO CONNECT GOLF COURSE DRIVE TO BERWICK DRIVE TO PROVIDE ACCESS BETWEEN THE BIRDWOOD GOLF COURSE AND THE BOAR'S HEAD INN. CONSTRUCTION ACTIVITIES INCLUDE EARTHWORK, PAVEMENT, STROMWATER MANAGEMENT, AND CULVERT AND STORM SEWER INSTALLATION. THE PROJECT AREA IS APPROXIMATELY 2.20 ACRES AND WILL DISTURB APPROXIMATELY 2.20 ACRES. 0.22 ACRES OF IMPERVIOUS AREA IS BEING ADDED. EXISTING SITE CONDITIONS THE EXISTING SITE CONSISTS OF BERWICK ROAD, GOLF COURSE DRIVE, GOLF CART PATHS AND THE BIRDWOOD GOLF COURSE. THE EXISTING SITE ALSO CONSISTS OF TREES AND GRASSY AREAS. SOILS SEE SHEET C2.03 FOR SOILS MAP. CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING, EROSION AND SEDIMENT CONTROL, MAINTENANCE, AND STABILIZATION OF SOILS DURING CONSTRUCTION. ADJACENT PROPERTY THE EXISTING SITE IS SOUTH OF ROUTE 250, EAST OF EDNAM VILLAGE ST, AND NORTH OF THE UVA SQUASH FACILITY. NO WORK WILL BE DONE ON ADJACENT PROPERTIES. OFFSITE ACTIVITIES ALL OFFSITE ACTIVITIES NEED TO BE ADDRESSED BY THE VSMP PERMIT HOLDER AND APPROPRIATE INFORMATION CONTAINED IN THE SWPPP. CONTRACTOR SHALL ONLY PERFORM OFFSITE ACTIVITIES THAT ARE COVERED UNDER THE PERMIT HOLDER FOR THIS PROJECT OR COVERED UNDER THE PERMIT OF ANOTHER PROJECT. STORMWATER RUNOFF CONSIDERATIONS THIS PROJECT WILL INCREASE IMPERVIOUS AREA AND STORMWATER RUNOFF. STORMWATER CALCULATIONS CAN BE FOUND IN THE STORM WATER PLANS, SHEETS C9.01 -C9.11. CRITICAL AREAS THERE ARE EXISTING AREAS OF STEEP SLOPES ON SITE. PLEASE REFER TO THE SITE SURVEY FOR LOCATIONS OF STEEP SLOPES. THE PLAN HAS BEEN DEVELOPED TO MINIMIZE LAND DISTURBANCE. WHERE GRADING IS NECESSARY ADEQUATE PRECAUTIONS SHALL BE TAKEN TO MINIMIZE EROSION AND TO CONTAIN SILT THROUGH PROPER EROSION AND SEDIMENT CONTROL PRACTICES. THE INTENT OF THIS EROSION AND SEDIMENT CONTROL PLAN IS TO GUIDE THE CONTRACTOR IN IMPLEMENTING ACCEPTABLE MEASURES, INFRASTRUCTURE AND MAINTENANCE PROGRAMS THAT WILL MINIMIZE THE AMOUNT OF EROSION AND RESULTING SEDIMENT THAT WILL TAKE PLACE DURING THE CONSTRUCTION OF THIS PROJECT. ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VA EROSION & SEDIMENT CONTROL HANDBOOK. EROSION AND SEDIMENT CONTROL MEASURES STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES SAFETY FENCE (VESCH STD. & SPEC. 3.01): A PROTECTIVE BARRIER INSTALLED TO PREVENT ACCESS TO AN EROSION CONTROL MEASURE. SAFETY FENCE PROHIBITS THE UNDESIREABLE USE OF AN EROSION CONTROL MEASURE BY THE PUBLIC. FOR USE IN AREAS POTENTIALY UNSAFE FOR THE PUBLIC. CONSTRUCTION ENTRANCE (VESCH STD. & SPEC. 3.02): STABILIZED STONE PAD WITH A FILTER FABRIC UNDERLINER LOCATED AT POINTS OF VEHICULAR INGRESS AND EGRESS. CONSTRUCTION ENTRANCES REDUCE THE AMOUNT OF MUD TRANSPORT ONTO PAVED PUBLIC ROADS BY VEHICLES OR RUNOFF. CONSTRUCTION ENTRANCES SHALL BE LIMITED TO THOSE SHOWN ON THE PLANS OR OTHERWISE APPROVED BY THE SOIL EROSION OFFICER. SUPPLEMENTAL DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR FOR APPROVAL IF ADDITIONAL ENTRANCES ARE REQUIRED. SILT FENCE (VESCH STD. & SPEC. 3.05): A TEMPORARY SEDIMENT BARRIER CONSISTING OF A FILTER FABRIC STRETCHED ACROSS AND ATTACHED TO SUPPORTING POSTS AND ENTRENCHED. SILT FENCE IS INSTALLED TO INTERCEPT AND DETAIN SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS DURING CONSTRUCTION IN ORDER TO PREVENT SEDIMENT FROM LEAVING THE SITE AND TO DECREASE THE VELOCITY OF SHEET FLOWS AND LOW -TO -MODERATE CHANNEL FLOWS. STORM DRAIN INLET PROTECTION (VESCH STD. & SPEC. 3.07): A SEDIMENT FILTER OR AN EXCAVATED IMPOUNDING AREA AROUND A STORM DRAIN DROP INLET OR CURB INLET. STORM DRAIN INLET PROTECTION PREVENTS SEDIMENT FROM ENTERING STORM DRAINAGE SYSTEMS PRIOR TO PERMANENT STABILIZATION OF THE DISTURBED AREA. FOR USE WHERE STORM DRAIN INLETS ARE TO BE MADE OPERATIONAL BEFORE PERMANENT STABILIZATION OF THE CORRESPONDING DISTURBED DRAINAGE AREA. DIFFERENT TYPES OF STRUCTURES ARE APPLICABLE TO DIFFERENT CONDITIONS. TEMPORARY SEEDING (VESCH STD. & SPEC. 3.31): THE ESTABLISHMENT OF A TEMPORARY VEGETATIVE COVER ON DISTURBED AREAS BY SEEDING WITH APPROPRIATE RAPIDLY GROWING ANNUAL PLANTS. TEMPORARY SEEDING REDUCES EROSION AND SEDIMENTATION BY STABILIZING DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A PERIOD OF MORE THAN 14 DAYS. TEMPORARY SEEDING REDUCES DAMAGE FROM SEDIMENT AND RUNOFF TO DOWNSTREAM OR OFF-SITE AREAS, AND TO PROVIDE PROTECTION TO BARE SOILS EXPOSED DURING CONSTRUCTION UNTIL PERMANENT VEGETATION OR OTHER EROSION CONTROL MEASURES CAN BE ESTABLISHED. FOR USE WHERE EXPOSED SOIL SURFACES ARE NOT TO BE FINE -GRADED FOR PERIODS OF LONGER THAN 14 DAYS. SUCH AREAS INCLUDED DENUDED AREAS, SOIL STOCKPILES, DIKES, DAMS, SIDES OF SEDIMENT BASINS, TEMPORARY ROADBANKS, ETC. (SEE MS#1 AND MS#2). A PERMANENT VEGETATIVE COVER SHALL BE APPLIED TO AREAS THAT WILL BE LEFT DORMANT FOR A PERIOD OF MORE THAN ONE (1) YEAR. PERMANENT SEEDING (VESCH STD. & SPEC. 3.32): THE ESTABLISHMENT OF A PERENNIAL VEGETATIVE COVER ON DISTURBED AREAS BY PLANTING SEED. PERMANENT SEEDING REDUCES EROSION AND DECREASES SEDIMENT YIELD FROM DISTURBED AREAS. PERMANENT SEEDING STABILIZES DISTURBED AREAS IN A MANNER THAT IS ECONOMICAL, ADAPTABLE TO SITE CONDITIONS, AND ALLOWS SELECTION OF THE MOST APPROPRIATE PLANT MATERIAL. PERMANENT SEEDING ALSO IMPROVES WILDLIFE HABITAT AND ENHANCES NATURAL BEAUTY. FOR USE IN DISTURBED AREAS WHERE PERMANENT, LONG-LIVED VEGETATIVE COVER IS NEEDED TO STABILIZE THE SOIL. FOR USE WHERE ROUGH -GRADED AREAS WHICH WILL NOT BE BROUGHT TO FINAL GRADE FOR A YEAR OR MORE. MULCHING (VESCH STD. & SPEC. 3.35): APPLICATION OF PLANT RESIDUES OR OTHER SUITABLE MATERIALS TO THE SOIL SURFACE. MULCHING PREVENTS EROSION BY PROTECTING THE SOIL SURFACE FROM RAINDROP IMPACT AND REDUCING THE VELOCITY OF OVERLAND FLOW. MULCHING FOSTERS THE GROWTH OF VEGETATION BY INCREASING AVAILABLE MOISTURE AND PROVIDING INSULATION AGAINST EXTREME HEAT AND COLD. FOR USE IN AREAS WHICH HAVE BEEN PERMANENTLY SEEDED. MULCHING SHOULD OCCUR IMMEDIATELY FOLLOWING SEEDING. AREAS THAT CANNOT BE SEEDED BECAUSE OF THE SEASON SHOULD BE MULCHED WITH AN ORGANIC MULCH. DUST CONTROL (VESCH STD. & SPEC. 3.39) APPLICATION OF TEMPORARY SEEDING (VESCH & SPEC. 3.31), MULCHING (VESCH STD. & SPEC. 3.35), IRRIGATION, SPRAY -ON ADHESIVES OR BARRIERS TO PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM EXPOSED SOIL SURFACES AND REDUCE THE PRESENCE OF AIRBORNE SUBSTANCES WHICH MAY PRESENT HEALTH HAZARDS, TRAFFIC SAFETY PROBLEMS OR HARM ANIMAL OR PLANT LIFE DURING LAND DISTURBING, DEMOLITION AND CONSTRUCTION ACTIVITIES. TEMPORARY AND PERMANENT STABILIZATION TEMPORARY SEEDING SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE, BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS AND LESS THAN ONE YEAR. THIS INCLUDES, BUT IS NOT LIMITED TO, STOCKPILES AND BORROW AREAS. PERMANENT SEEDING SHALL BE APPLIED AND A PERENNIAL VEGETATIVE COVERING SHALL BE ESTABLISHED ON DISTURBED AREAS WITHIN SEVEN DAYS OF BEING BROUGHT TO FINAL GRADE ON AREAS NOT OTHERWISE PROTECTED. SELECTION OF THE SEED MIXTURE SHALL DEPEND ON THE TIME OF YEAR IT IS TO BE APPLIED. MULCHING SHALL BE APPLIED TO ALL PERMANENT SEEDING IMMEDIATELY UPON COMPLETION OF SEED APPLICATION. MULCH LIBERALLY DURING THE MID -SUMMER AND WINTER SEASONS. SEE VIRGINIA EROSION AND SEDIMENT CONTROL TECHNICAL BULLETIN NO. 4, NUTRIENT MANAGEMENT FOR DEVELOPMENT SITES, FOR UPDATED SEED MIXTURES AND SCHEDULES AS WELL AS UPDATED LIMING, MULCHING, AND FERTILIZING REQUIREMENTS. SEE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK STD. AND SPEC. 3.35 FOR MULCHING SPECIFICATIONS. PERMITS PROJECT DISTURBANCE IS MORE THAN 1 ACRE. THEREFORE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) PERMIT AND MAINTAINING A STORMWATER POLLUTION PREVENTION PLAN (SWPPP). THE PROJECT IS MORE THAN 10,000 SF AND WILL REQUIRE EROSION AND SEDIMENT REVIEW APPROVAL. EROSION & SEDIMENT CONTROL MAINTENANCE IN GENERAL, THE PROJECT AREA SHALL BE CHECKED WITHIN 24 HOURS OF EACH RAINFALL EVENT OR WEEKLY IF NO RAINFALL EVENT HAS OCCURED, WHICH EVER IS MORE FREQUENT TO ENSURE THAT ALL EROSION AND SEDIMENT CONTROL DEVICES ARE IN WORKING ORDER. EROSION CONTROL DEVICES SHALL BE MAINTAINED ACCORDING TO THE FOLLOWING SCHEDULE: 1. SAFETY FENCE SAFETY FENCE SHALL BE CHECKED REGULARLY FOR WEATHER-RELATED OR OTHER DAMAGE. ANY NECESSARY REPAIRS MUST BE MADE IMMEDIATELY. CARE SHOULD BE TAKEN TO SECURE ALL ACCESS POINTS (GATES) AT THE END OF EACH WORK DAY. ALL LOCKING DEVICES MUST BE REPAIRED OR REPLACED AS NECESSARY. 2. CONSTRUCTION ENTRANCE THE ENTRANCE SHALL BE MAINTAINED IN CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR THE WASHING AND REWORKING OF EXISTING STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY STRUCTURES USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED OR TRACKED FROM VEHICLES ONTO ROADWAYS OR INTO STORM DRAINS MUST BE REMOVED IMMEDIATELY. THE USE OF WATER TRUCKS TO REMOVE MATERIALS DROPPED. WASHED OR TRACKED ONTO ROADWAYS WILL NOT BE PERMITTED UNDER ANY CIRCUMSTANCES. 3. SILT FENCE A. SEDIMENT DEPOSITS SHALL BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER. B. FABRIC SHALL BE REPLACED IF IT HAS DECOMPOSED OR BECOME INEFFECTIVE. 4. SEEDING THE SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RESEEDED AS NEEDED. 5. STORM DRAIN INLET PROTECTION SEDIMENT DEPOSITS SHALL BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-HALF THE DESIGN DEPTH OF THE TRAP. 6. TEMPORARY SEDIMENT TRAP A. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE HALF THE DESIGN VOLUME OF THE WET STORAGE. SEDIMENT REMOVAL FROM THE BASIN SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE AND CAUSE SEDIMENTATION PROBLEMS. B. FILTER STONE SHALL BE REGULARLY CHECKED TO ENSURE THAT FILTRATION PERFORMANCE IS MAINTAINED. STONE CHOKED WITH SEDIMENT SHALL BE REMOVED AND CLEANED OR REPLACED. C. THE STRUCTURE SHOULD BE CHECKED REGULARLY TO ENSURE THAT IT IS STRUCTURALLY SOUND AND HAS NOT BEEN DAMAGED BY EROSION OR CONSTRUCTION EQUIPMENT. THE HEIGHT OF THE STONE OUTLET SHOULD BE CHECKED TO ENSURE THAT ITS CENTER IS AT LEAST 1 FOOT BELOW THE TOP OF THE EMBANKMENT. 7. DUST CONTROL IN PLANNING AND MAINTENANCE FOR DUST CONTROL, LIMITING THE AMOUNT OF SOIL DISTURBANCE AT ANY ONE TIME SHOULD BE A KEY OBJECTIVE. TEMPORARY STABILIZATION MEASURES SHALL BE CHECKED REGULARLY AND RE-APPLIED AS NECESSERY TO REDUCE DUST EMISSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN EMPLOYEE WHO WILL BE RESPONSIBLE OF THE EROSION AND SEDIMENT CONTROL PLAN AND REQUIREMENTS FOR THE PROJECT THAT IS CERTIFIED BY THE VIRGINIA DEPARTMENT OF CONSERVATION OR THE VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY AND RECREATION AS A RESPONSIBLE LAND DISTURBER (RLD). THE NAME OF THE CONTRACTOR'S RLD AND COPY OF HIS CURRENT CERTIFICATION SHALL BE PROVIDED TO THE OWNER, ENGINEER AND EROSION & SEDIMENT CONTROL PLAN APPROVING AUTHORITY PRIOR TO ISSUANCE TO THE NOTICE TO PROCEED FOR THE PROJECT. GENERAL EROSION & SEDIMENT CONTROL NOTES ES -1: UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND THE VIRGINIA EROSION AND SEDIMENT CONTROL REGULATIONS (9VAC25-840). ES -2: THE PLAN -APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. THE NAME OF THE RESPONSIBLE LAND DISTURBER MUST BE PROVIDED TO THE PLAN -APPROVING AUTHORITY PRIOR TO ACTUAL ENGAGEMENT IN THE LAND -DISTURBING ACTIVITY SHOWN ON THE APPROVED PLAN. IF THE NAME IS NOT PROVIDED PRIOR TO ENGAGING IN THE LAND -DISTURBING ACTIVITY, THE PLAN'S APPROVAL WILL BE REVOKED. ES -3: ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. ES -4: A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. ES -5: PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF-SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN -APPROVING AUTHORITY. ES -6: THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN -APPROVING AUTHORITY. ES -7: ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED, AFTER WHICH, UPON APPROVAL OF THE PLAN -APPROVING AUTHORITY, THE CONTROLS SHALL BE REMOVED. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE REMOVAL OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. ES -8: DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE. ES -9: THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES AT LEAST AFTER EACH RUNOFF -PRODUCING RAINFALL EVENT OR WEEKLY. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. ES -10: THE CONTRACTOR IS RESPONSIBLE FOR THE DAILY REMOVAL OF SEDIMENT THAT HAS BEEN TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE. ES -11: SEEDING OPERATIONS SHALL BE INITIATED WITHIN 7 DAYS AFTER REACHING FINAL GRADE OR UPON SUSPENSION OF GRADING OPERATIONS FOR ANTICIPATED DURATION OF GREATER THAN 14 DAYS OR UPON COMPLETION OF GRADING OPERATIONS FOR A SPECIFIC AREA. ES -12: THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING SURFACE AND AIR MOVEMENT OF DUST FROM EXPOSED SOILS WHICH MAY PRESENT HEALTH HAZARDS, TRAFFIC SAFETY PROBLEMS, OR HARM ANIMAL OR PLANT LIFE. ES -13: A VIRGINIA STORMWATER MANAGEMENT PROGRAM PERMIT (VSMPP) FOR THE DISCHARGE OF STORMWATER FROM CONSTRUCTION ACTIVITIES IS REQUIRED FOR PROJECTS DISTURBING 1 ACRE OR GREATER. VISIT THE VIRGINIA STORMWATER MANAGEMENT PROGRAM PERMITTING WEB PAGE AT HTTP1/WWW.DEQ.STATE.VA.US/PROGRAMS/WATER/STORMWATERMANAGEMENT/VSMPPERMITS/CONSTRUCTIONGENERALPERMIT.ASPX FOR MORE INFORMATION. EROSION AND SEDIMENT MINIMUM STANDARDS 1. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. SPECIFIC FERTILIZER, NUTRIENT, & SEED APPLICATION MUST MEET EROSION AND SEDIMENT CONTROL (ESC) TECHNICAL BULLETIN NO. 4 NUTRIENT MANAGEMENT FOR DEVELOPMENT PROJECTS. DOWNLOAD AT http://www.deq.virginic.gov/Programs/Water/StormwaterManagement/Publicctions.cspxl. MULCHING REQUIREMENTS MUST MEET VESC HANDBOOK MULCHING TABLE 3.35A. 2. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. ANY BORROW, FILL, OR WASTE SUCH AS DEMOLITION MATERIAL MUST BE PROVIDED FROM OR HAULED TO A PERMITTED, APPROVED, SUPPLY OR WASTE AREA. ALL OFFSITE ACTIVITY IS NOT PART OF THIS PERMIT/ PLAN SET AND IS ADDRESSED UNDER SEPARATE COVER. SOIL STOCKPILES ARE NOT ANTICIPATED ONSITE. 3. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 4. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 5. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 6. SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. A. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. B. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25 -YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. 7. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. EROSION AND SEDIMENT MINIMUM STANDARDS 8. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 9. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 10. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 11. BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 12. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE 13. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 14. ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. 15. THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. F. APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. 17. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND -DISTURBING ACTIVITIES. 18. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE REGULATORY AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 19. PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE STANDARDS AND CRITERIA FOUND IN VESC REGULATION 94VAC25-840-40 MS -19 PARTS A -N FOUND AT WEBPAGE HTTP://LIS.VIRGINIA.GOV/CGI-BIN/LFGP604.FXF?000+REG+9VAC25-840-40 EROSION AND SEDIMENT CONTROL SEQUENCE 1. CONTRACTOR TO INSTALL EROSION AND SEDIMENT PHASE I CONTROLS. 2. CONTRACTOR TO COMPLETE DEMOLITION. 3. CONTRACTOR TO COMPLETE SITE IMPROVEMENTS. 4. CONTRACTOR TO REMOVE APPROPRIATE TEMPORARY EROSION AND SEDIMENT PHASE I CONTROLS. 5. CONTRACTOR TO INSTALL EROSION AND SEDIMENT PHASE II CONTROLS. 6. CONTRACTOR TO STABILIZE SITE. 7. CONTRACTOR TO REMOVE ALL TEMPORARY EROSION AND SEDIMENT CONTROLS. 8. ALL BIORETENTION AREAS SHALL BE PROTECTED FROM SOIL LADEN RUNOFF. CONTRACTOR SHALL BEGIN CONSTRUCTION OF THE BIORETENTION AREAS ONLY ONCE ALL UPSTREAM AREAS OF THE SITE HAVE BEEN FULLY STABILIZED. BIORETENTION INSTALLATION NOTES: 1. STABILIZE ENTIRE CONTRIBUTING DRAINAGE AREA WITH VEGETATION. BLOCK INLETS AS NECESSARY. ENSURE NO UTILITIES SHALL INTERFERE WITH THE INSTALLATION. 2. HOLD A PRECONSTRUCTION MEETING WITH THE ENGINEER, OWNER AND CONTRACTOR. ANY CHANGES DURING THIS MEETING SHALL BE DOCUMENTED AS PART OF THE AS -BUILT SUBMISSION OF THE FACILITY. 3. EMPLOY EROSION AND SEDIMENT CONTROLS AS NECESSARY TO DIVERT STORMWATER AWAY FROM THE BIORETENETION FACILITY UNTIL INSTALLATION IS COMPLETE. 4. EXCAVATE PRE-TREATMENT CELLS FIRST, AND SEAL THEM TO TRAP SEDIMENT. 5. WHEN POSSIBLE, UTILIZE EXCAVATORS AND BACKHOES FROM THE SIDES OF THE BIORETENTION AREA TO AVOID COMPACTING OF SUBGRADE AND TO ENSURE APPROPRIATE DESIGN DEPTH AND DIMENSIONS. 6. RIP THE SUBGRADE SOILS C-12" TO PROMOTE GREATER INFILTRATION. 7. PLACE A GEOTEXTILE FABRIC ON THE VERTICAL SIDES OF THE RORETENTION CELL WITH A 6" OVERLAP BETWEEN FABRIC EDGES. PLACE THE BOTTOM STORAGE LAYER. INSTALL THE UNDERDRAIN. PACK THE STONE. ADD CHOKER LAYER ABOVE. 8. APPLY THE BIOFILTER SOIL MEDIA FROM A QUALIFIED VENDOR IN 12" LIFTS TO THE DESIRED ELEVATION OF THE RORETENTION. ALLOW FOR A FEW DAYS OF SETTLEMENT, THEN ADD ADDITIONAL SOIL MEDIA TO DESIRED ELEVATION. ENSURE SOIL MEDIA IS KEPT AWAY FROM POTENTIAL POLLUTANTS INCLUDING SEDIMENT. 9. PREPARE PLANTING HOLES AND WATER ACCORDINGLY. 10. PLACE THE SURFACE COVER OF THE CELLS PER THE DESIGN. 11. INSTALL THE PLANT MATERIAL AND WATER PER THE LANDSCAPING PLAN. BMP INSTALLATION AND AS -BUILT NOTES 1. CONTRACTOR TO PROVIDE DETAILED INFORMATION ON ANY INSTALLED STORMWATER BMP. THIS INFORMATION SHALL INCLUDE A TOPOGRAPHIC SURVEY OF THE INSTALLATION, GPS COORDINATES FOR EACH FACILITY, PHOTOGRAPHS OF THE PROGRESS THROUGHOUT CONSTRUCTION INCLUDING EACH MILESTONE, CONSTRUCTION LOGS, GEOTECHNICAL TESTING REPORTS, AND SOIL REPORT CERTIFICATIONS. THIS INFORMATION TO BE TURNED OVER TO THE OWNER AS A SUBMITTAL FOLLOWING CONSTRUCTION OF THE PROJECT. 2. THE ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS FROM THE PLANS IMMEDIATELY. IF A DEVIATION IS REQUIRED, CONTRACTOR AND ENGINEER SHALL COORDINATE A SOLUTION THAT IS ACCEPTABLE WITHIN THE DEQ REGULATIONS. 3. CONTRACTOR SHALL PROTECT BMP FROM ANY DUST OR DEBRIS THROUGHOUT CONSTRUCTION, INCLUDING UNTIL THE OWNER HAS SIGNED OFF ON THE TURNOVER OF THE FACILITY. 41__t��Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) L.I_ o z D O W wQ - O �O ~c� Qp� �z �p0 Uv �w O U B,� - U) U LL 3: z� � LL W O� pU W J Z Cpm U� �OZ O (DG O� o O ry U LL SEAL - �'�Sp►LT1Y0A �O �, TTEW .ZS Lic. No, 465 1 �S Ip Ai.E�G� SCALE No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE EROSION & SEDIMENT CONTROL NOTES PROJECT NO. 50097555 C8.05 SHEET NO. OF E � or C to SAFETY FENCE PERSPECTIVE VIEW hm'wroi, 'Iii '' ,rte � �- PERSPECTIVE VIEW PERSPECTIVE VIEW PLASTIC FENCE METAL FENCE Source: Adapted from Comved Plastics and VDOT Road and Bridge Standards H1_5 C E 1992 3.01 3'02 (SF 199 2 CONSTRUCTION ENTRANCESTONE 70' HIM. EXIST114G Sept. 1 -Feb. 1 b MULCHES: 1 6j"��� Per Acre mill II -II -II -II 11 - - - CLOTH ­_ e MIN.1 j 'MOUNTABLE BERM 15 - 2 tons 70 - 90 lbs. ELEVATIONFILTER SIDE 1 (Minimum 2 Tall Fescue' matter. Must be anchored. 6.2 tons for 128 lbs. Spread with mulch blower Red Top Grass or Creeping Red Fescue Seasonal Nurse Crop WASHRACK 10, MIR or by hand. Fiber Mulch ,OPTION AL, 35 lbs. Do not use as mulch for 108 lbs. 1500 lbs. Red Top Grass or Creeping Red Fescue winter cover or during hot, Low -Maintenance Slope 12, MIN II IIIIIII:$~y'�L•':': dry periods.' Apply as EXIS ING Crownvetch3 II_lidy, slurry. Corn Stalks ST -ry:PA PAVEMENT Cut or shredded in 4-6" variety list is available at the local County Extension office or through VCIA at 804-746-4884 or at http-//sudan.eses-vt.edu/htmi rurf/turf/publications/oublications2.htmI 2 - Use seasonal nurse crop in accordance with seeding dates as stated below: lengths. Air-dried. Do not P SITIVE DRAINAGEV DO T .1 P IT US IV DRAINAGE\'. 10' KIN. November- February 1551 ....................... Winter Rye To SED MONT COURSE AGGREGATE T SEDIMENT B all other periods, use unhulled Sericea). If Flatpea is used, increase rate to 30 lbs./acre. If Weeping Lovegrass is used, include in any slope or low maintenance mixture during warmer seeding periods, increase to 30 -40 TR PPf IS r TRAPPING DEVICE with mulch blower or by MUST EXTEND FULL WIDTH hand. OF INGRESS AND EGRESS PLAN VIEW 4 - 6 tons OPERAMON Free of coarse matter. Air- dried. Treat witb 12 lbs FILTER CLET SECTION nitrogen per ton. Do not �•rralCS��i�rpM+��r��: CONCRETE �ul.r DRAIN SPACE SECTIONREINFORCED use in fine turf areas. Apply Plate 3.01-1 Source: Adapted from 1983 Maryland Standards for Soil Plate 3.02-1 Erosion and Sediment Control, and Va. DSWC 111-9 3.18 CD 1992 3.20 (T* PIPE OUTLET CONDITIONS A A 3 d ------------- " do ------------ -'�.�1 PIPE OUTLET TO FIAT AREA WITH NO DEFINED PLAN VIEW CHANNEL I~ L a 0% A- d SECTION A -A FILTER CLOTH KEY IN 8"-9"; RECOMMENDED FOR ENTIRE PERIMETER A I A 3do (MIN.) do OUTLET TO WELL DEFINED CHANNEL PLAN VIEW L a oxo d SECTION A -A FILTER CLO[H KEY IN 6"-9': RECOMMENDED FOR ENTIRE PERIMETER NOTES: 1. APRON LINING MAY BE RIPRAP. GROUTED RIPRAP, GABION BASKET. OR CONCRETE. 2. La IS THE LENGTH OF THE RIPRAP APRON AS CALCULATED USING PLATES 3.18-3 AND 3.16-4. 3. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER. BUT NOT LESS THAN 6 INCHES, Source: Va. DSWC c 1992 111- 157 Plate 3.18-1 TABLE 3.35-A ORGANIC MULCH MATERIALS AND APPLICATION RATES SPECIES RATES: Sept. 1 -Feb. 1 b MULCHES: NOTES: Per Acre Per 1000 sq. ft. Straw or Hay 15 - 2 tons 70 - 90 lbs. Free from weeds and coarse 1 (Minimum 2 Tall Fescue' matter. Must be anchored. 6.2 tons for 128 lbs. Spread with mulch blower Red Top Grass or Creeping Red Fescue Seasonal Nurse Crop winter cover) 12.4 or by hand. Fiber Mulch Minimum 35 lbs. Do not use as mulch for 108 lbs. 1500 lbs. Red Top Grass or Creeping Red Fescue winter cover or during hot, Low -Maintenance Slope Seasonal Nurse CropZ 20 lbs. dry periods.' Apply as Crownvetch3 20 lbs slurry. Corn Stalks 4 - 6 tons 185 - 275 lbs. Cut or shredded in 4-6" variety list is available at the local County Extension office or through VCIA at 804-746-4884 or at http-//sudan.eses-vt.edu/htmi rurf/turf/publications/oublications2.htmI 2 - Use seasonal nurse crop in accordance with seeding dates as stated below: lengths. Air-dried. Do not May 1"- August 151° ........................... Foxtail Millet August I SRI - October ...... Annual Rye November- February 1551 ....................... Winter Rye use in time turf areas. Apply all other periods, use unhulled Sericea). If Flatpea is used, increase rate to 30 lbs./acre. If Weeping Lovegrass is used, include in any slope or low maintenance mixture during warmer seeding periods, increase to 30 -40 with mulch blower or by hand. Wood Chips 4 - 6 tons 185 - 275 lbs. Free of coarse matter. Air- dried. Treat witb 12 lbs nitrogen per ton. Do not use in fine turf areas. Apply with mulch blower, chip handler, or by hand. Bark Chips 50 - 70 cu. 1-2 cu. yds. Free of coarse matter. Air - or yds. dried. Do not use in fine Shredded turf areas. Apply with Bark mulch blower, chip handler, or by hand, * When fiber mulch is the only available mulch during periods when straw should be used, apply at a minimum rate of 2000 lbs./ac. or 45 lbs./1000 sq. ft. Source: Va. DSWC III - 353 Source: Va. DSWC Plate 3.20-1 111-187 STONE 70' MIN. CONSTRUCTION ACCESS 3- SM -2A ASPHALT TOP COURSE EXISTING 296 7x rPAVr'V7'J' -- 1 6" MIN, 21A AGGREGATE BASE PROFIL STONE 70' MIN, CONSTRUCTION ASPHALT PAVED ACCESS A WASHRACK EXISTING 2% 2% PAVFMFNT l2% 12' MIN. - 'MUST EXTEND FULL WIDTH L@ �-TO ITIVE SEDI DRAINAGE OF INGRESS AND EGRESS TO [DIMENIT OPERATION TRAPPING DEVICE PLAN 12' MIN. POSITIVE UItA+NAGI. 2Y TO SEOIMEN17 TRAPPING DEVICE FILTER CLOTH) SECTION A -A A nuttnmmm water tap of 1 inch unit be installed with a nirwtuun 1 itch ballcocL shutoffvah,e sttppbimg a wash (lose with a diameter of 1.5 itches for adecptate constant pressure. Wash water must be carried away 5ont the entrance to an approved settfulg area to remove sediment. AFI seclunetit sitif be preveiited front emtetut2 stone cholla. ditches or watelrmu<es PAVED WASH RACK NO SC& F P 1992 3.05 CONSTRUCTION OF A SILT FENCE (WITHOUT WIRE SUPPORT) 1. SET THE STAKES, 2. EXCAVATE A 4"X 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES. s•MAx. Ftoly a" 3. STAPLE FILTER MATERIAL 4. BACKFILL AND COMPACT TO STAKES AND EXTEND THE EXCAVATED SOIL. IT INTO THE TRENCH. / i Ill! r FLOW III "' =III SHEET FLOW INSTALLATION (PERSPECTIVE VIEW) I I I I A I FLOWI'} B I A \\\ "I ovlD POINTS A SHOULD BE HIGHER THAN POINT B. DRAINAGEWAY INSTALLATION (FRONT ELEVATION) Source: Adapted from Installation of Straw and Fabric Filter Barriers for Sediment Control, Sherwood and Wyant Plate 3.05-2 III - 25 TABLE 3.31-B (Revised June 2003) TEMPORARY SEEDING SPECIFICATIONS QUICK REFERENCE FOR ALL REGIONS SEED APPLICATION DATES SPECIES APPLICATION RATES Sept. 1 -Feb. 1 b 50150 Mix of Annual Ryegrass (lolium multi- florum) & Cereal (Winter) Rye (Secale cereals) 50 -100 (Ibsracre) Feb. 16 - Apr. 30 Annual Ryegrass (lolium multi-florum) 60 - 100 (lbs/acre) May 1 -Aug. 31 German Millet 1 50 (lbs/acre) FERTILIZER ii LIME a Apply 10-10-10 fertilizer at a rate of 450 lbs. / acre (or 10 lbs. 11,000 sq. ft.) • Apply Pulverized Agricultural Limestone at a rate of 2 tonslacre (or 90 lbs. / 1,000 sq. ft.) NOTE: 1 - A soil lest is necessary to determine the actual amount of lime required to adjust the soil pH of site. 2 - Incorporate the lime and fertilizer into the top 4 - 6 inches of the soil by disking or by other means. 3 - When applying Slowly Available Nitrogen, use rates available in Erosion & Sediment Control Technical Bulletin # 4. 2003 Nutrient Management for Development Sites at htt0:!lwww.dcr.state.va.us/sw/e&s.htm#Dubs BLOCK & GRAVEL CURB INLET SEDIMENT FIL TER CURB INLET f E r � WIRE SCREEN CONCRETE BLOCK 1 GRAVEL FILTER RUNOFF OVERFLOW WATER WITH FILTERED WATER SEDIMENT SEDIMENT I- II WIRE SCREEN 2' x 4' WOOD STUD CURB INLET SPECIAL APPLICATION THIS METHOD OF INLET PROTECTION IS APPLICABLE AT CURB INLETS WHERE AN OVERFLOW CAPABILITY IS NECESSARY TO PREVENT EXCESSIVE PONDING IN FRONT OF THE STRUCTURE- - GRAVEL SHALL BE VDOT #3, #357 OR #5 COARSE AGGREGATE Source: Va. DSWC PS III - 45 TABLE 3.32-1) (Revised June 2003) PERMANENT SEEDING SPECIFICATIONS FOR PIEDMONT AREA 3.07 ' P 1992 Plate 3.07-8 SEED' LAND USE SPECIES APPLICATION PER ACRE OF TOPSOIL REQUIRED Tall Fescue' 95-100 Minimum Care Lawn Perennial Ryegrass 0-5 (Commercial or Residentiall Kentucky Bluegrass' 0-5 TOTAL: 175-200 lbs. 1 Hiah-Maintenance Lawn Tall Fescue' TOTAL: 200-250 lbs. 6.2 Tall Fescue' 128 lbs. General Slope (3:1 or less) Red Top Grass or Creeping Red Fescue Seasonal Nurse Crop 2 lbs. 20 lbs. 12.4 537 5 TOTAL: 150 lbs. 672 Tall Fescue' 108 lbs. 806 Red Top Grass or Creeping Red Fescue 2 Ips. Low -Maintenance Slope Seasonal Nurse CropZ 20 lbs. (Steeper than 3:1) Crownvetch3 20 lbs TOTAL: 150 lbs. 1 - When selecting varieties of turfgrass, use the Virginia Crop Improvement Association (VCIA) recommended turfgrass variety list. Quality seed will bear a label indicating that they are approved by VCIA. A current turigrass variety list is available at the local County Extension office or through VCIA at 804-746-4884 or at http-//sudan.eses-vt.edu/htmi rurf/turf/publications/oublications2.htmI 2 - Use seasonal nurse crop in accordance with seeding dates as stated below: February 16" -April ............................... Annual Rye May 1"- August 151° ........................... Foxtail Millet August I SRI - October ...... Annual Rye November- February 1551 ....................... Winter Rye 3 -S U bstilute Sericea lespedeza for Crownvetch east of Farmville, VA (May through September use hulled seed, all other periods, use unhulled Sericea). If Flatpea is used, increase rate to 30 lbs./acre. If Weeping Lovegrass is used, include in any slope or low maintenance mixture during warmer seeding periods, increase to 30 -40 FERTILIZER & LIME a Apply 10-20-10 fertilizer at a rate of 500 lbs. / acre (or 12 lbs. / 1,000 sq. ft.) • Apply Pulverized Agricultural Limestone at a rate of 2 tonslacre (or 90 lbs. / 1,000 sq. ft.) NOTE: - A soil test is necessary to determine the actual amount of lime required to adjust the soil pH of site. - Incorporate the lime and fertilizer into the top 4 - 6 inches of the soil by disking or by other means. - When applying Slowly Available Nitrogen, use rates available in Erosion & Sediment Control Technical Bulletin # 4. 2003 Nutrient Manaaement for Development Sites at http:/ANww.der.state.va.us/sw/e&s.htm#nubs 3.07 nc, 1992 BLOCK AND GRAVEL I.I, INLET SEDIMENT FIL TER WIRE SCREEN CONCRETE BLOCK r�,�w�j � �4.�I � nw � ► w tia GRAVEL! FILTER WIRE SCREEN OVER F FILTERED WATER R OF UN F DROP INLET SEDIMENT D WITH GRATE SPECIFIC APPLICATION THIS T a� F`r»a+ey l %�1� � ip�•rs1=i�T•rJ Wr�ktt�Ms•�v� +sf111v� •Tr*��,r.1+' ..••_�-��nn - y METHOD OF INLET PROTECTION FLOWSHEAVY 1 AND WHERE AN OVERFLOW CAPACITY IS NECESSARY TO PREVENT EXCESSIVE PONDING AROUND THE STRUCTURE. GRAVEL SHALL BE 11 OR #5 COARSE Source: Va. DSWC Plate 3.07-3 III - 38 Source: Va. DSWC 3.08 SILT FENCE CULVERT INLET PROTECTION ENDWAIL --------- - --- ----------------- ---- `,---rte TOE Of FILL I t-- CULVERT I �I I 1 I I __________ TOE OF FILL SILT FENCE 'DISTANCE IS 6• MINIMUM IF ROW I 4 $ TOWARD D EMfWJKMENT FLOW OPTIONAL STONE COMBINATION FLOW N - 2.5' VDOT 03, #357 OR #5 COPRSE AGGREGATE CUSS I RIPRAP TO REPLACE SILT FENCE IN ' HORSESHOE WHEN HIGH VELOCITY OF FLOW IS EXPECTED Source: Adapted from VDOT Standard Sheets and Va. DSWC Plate 3.08-1 119-49 Dewberry`R Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) 0. �wLU 0 0 U)< ��� �O U� Q�::) 0� D~ ��� O� �w 00 vv �2 0-I�U J� Ov _J W ow UO w0Z m 00 �Ur Z �O o O 01-- o U �LL _ YYa SEAL - VALTIf O N� 160 TT EW Z31G1 S LIC. No, 465 1 ,; �►�0 3 ��/� w� �S Ip Ai.E�G� SCALE No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY UK CHECKED CHECKED BY MCT DATE MARCH 2018 TITLE EROSION & SEDIMENT CONTROL DETAILS PROJECT NO. 50097555 C8006 SHEET NO. OF TABLE 3.30-A CUBIC YARDS OF TOPSOIL REQUIRED FOR APPLICATION TO VARIOUS DEPTHS Depth Per 1,000 inches Square Feet Per Acre 1 3.1 134 2 6.2 268 3 9.3 403 4 12.4 537 5 15.5 672 6 18.6 806 Source: Va. DSWC 3.08 SILT FENCE CULVERT INLET PROTECTION ENDWAIL --------- - --- ----------------- ---- `,---rte TOE Of FILL I t-- CULVERT I �I I 1 I I __________ TOE OF FILL SILT FENCE 'DISTANCE IS 6• MINIMUM IF ROW I 4 $ TOWARD D EMfWJKMENT FLOW OPTIONAL STONE COMBINATION FLOW N - 2.5' VDOT 03, #357 OR #5 COPRSE AGGREGATE CUSS I RIPRAP TO REPLACE SILT FENCE IN ' HORSESHOE WHEN HIGH VELOCITY OF FLOW IS EXPECTED Source: Adapted from VDOT Standard Sheets and Va. DSWC Plate 3.08-1 119-49 Dewberry`R Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) 0. �wLU 0 0 U)< ��� �O U� Q�::) 0� D~ ��� O� �w 00 vv �2 0-I�U J� Ov _J W ow UO w0Z m 00 �Ur Z �O o O 01-- o U �LL _ YYa SEAL - VALTIf O N� 160 TT EW Z31G1 S LIC. No, 465 1 ,; �►�0 3 ��/� w� �S Ip Ai.E�G� SCALE No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY UK CHECKED CHECKED BY MCT DATE MARCH 2018 TITLE EROSION & SEDIMENT CONTROL DETAILS PROJECT NO. 50097555 C8006 SHEET NO. OF 1 7 -1 d ti R C DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O �w0 u Q � ��� 0�O c) ::) 0� Z� O�e 0z ADO UV I--- Lu Ove ,� U� LL U J� z _j Lu Ow 00 W0 Z Om U HZ o 0 UO� o O � U LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE LV No. DATE BY Descrlptlon /ISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE SWM NARRATIVE AND CALCULATIONS L PROJECT NO. 50097555 C9001 SHEET NO. OF E X C Fj 1 PRE -DEV ELOPED LAND COVER MAP 2 1 3 1 4 1 5 1 6 TOTAL AREA = 2.20 ACRES POST -DEVELOPED LAND COVER MAP TOTAL AREA = 2.20 ACRES 41__t��Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) ry Q oo O TWO )< � U) U) �O Uc/) 00 vLu v O�� v~ �� z� 0-LLJ� Ov 2i J W O0w UO wpz m �oo 0 OO pO c:) U r LL SEAL o��gALT1Y °AG O TT EW Lic. No. 465 1 10 SCALE SCALE: 1" = 50' 0 50' 100' No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE PRE AND POST DEVELOPED LAND COVER AREA PROJECT NO. 50097555 C9.02 SHEET NO. OF E X C W 1 2 3 4 WATER QUALITY NARRATIVE BIORETENTION DRAINAGE AREA THIS PROJECT WAS ANALYZED USING THE RE -DEVELOPMENT VIRGINIA RUNOFF REDUCTION METHOD. THIS PROJECT DISTURBS A TOTAL OF 2.20 ACRES AND REQUR/ES A PHOSPHORUS REMOVAL OF 0.85 LB/YR.THE PROPOSED BIORETENTION TREATS 0.9/ AC OF SITE AREA AND HAS A TOTAL DRAINAGE AREA OF 1.60 ACRES. THE BIORETENTION REMOVES 0.86 LB/YR AND THEREFORE THE PROJECT MEETS WATER QUALITY. BIORETENTION BASIN #1 BIORETENTION BASIN *l WAS DESIGNED TO BE A LEVEL 2 SYSTEM WITH A REQUIRED TREATMENT VOLUME OF 0.04 AC -FT. THE BASIN WAS DESIGNED WITH A TREATMENT VOLUME OF 0.13 AC -FT. THE TWO FORMS OF PRETREATMENT HAVE BEEN PROVIDED THROUGH A GRAVEL DIAPHRAGM AND A PRE-TREATMENT CELL. ! DOrb11l BIO 1 - Bioretention Sizing Sizing Required for Bioretention Basin (Per VA DCR Stormwater Design Specification No. 9) Treatment Volume (Tv): TvBMP - P)(Rv)(A) 1yJ + any remaining volume from upstream BMP Rv = 0.46 Area (A)= 0.91 acres Remaining Volume = 0 acre -ft TvBMP = 0.035 acre -ft Biofilter Sizing Required (SA): Surface Area Computation (Equation 9.4: Bioretention Level 2 Design Surface Area) SA (sq. f t.) -_ (1.25 * TVBMP) - the volume reduced by an upsteam BMP 1.65 f t TVBMP = 1528.59 Volume Reduced= sq.fl. SA= 1158.03 sq.ft- Area shown on plans. 1536 sq.ft. Area left untreated by bloretention: -377.975 sq.fl. Shortest Flow Path Ratio Length (Equation 9.5): Level 2 - Ratio must be 0.8 or greater SFP Rat:o = L Shortest Flow Path (SFP) = 160 ft. Length (L) = 160 It. Ratio = 1 RV CALCULATIONS: Land Cover (HSG C Soils) Impervious = 0.31 ac Managed Turf = 0.57 ac Forested = 0.03 ac Land Cover Rv Impervious = 0.95 Managed Turf = 0.22 Forested = 0.04 Rv = ((0.31 * 0.95) + (0.57 * 0.22) + (0.03 * 0.04))/ (0.31 + 0.57 + 0.03 Rv = 0.46 6" DIA. PVC CLEAN-OUT BMP SURFACE WITH THREADED CAPS 2" HARDWOOD MULCH 3:1 (VA CLEARING HOUSE SPEC. NO. 9 TABLE 9.6) 6" 2.. MIN. T FILTER MEDIA (VA CLEARING HOUSE SPEC. NO. 9 TABLE 9.6) PLACE GEOTEXTILE FILTER FABRIC ON THE c VDOT #57 STONE SIDES OF THE BMP Qo0oQoC�� � O�o�12 0 �o�oQo 6" DIA. PERFORATED PVC @ 0.5% MIN BIORETENTION DETAIL - LEVEL 2 N.T.S. SHEET FLOW EEE'MIN- 2% 4" DROP 2' MIN­­�--2' MI 5;1 BOTTOM OF BIORETENTION GEOTEXTILE VDOT CLASS FILTER FABRIC 1 RIPRAP V MIN WITH 1:1 SIDE SLOPES PRETREATMENT - GRAVEL DIAPHRAGM DETAIL FOR SHEET FLOW FROM IMPERVIOUS OR PREVIOUS N.T.S. SWM DA = I.6 AC ------ xl'� i i I I ii' I I II \ \ \ i i I V !SWM EASEMENTI_ SITE AREA = 0.91 AC i IMPERVIOUS TREATED = 0,31 AC PERVIOUS TREATED = 0,60 AC / �DRETENTION1. BASIN 1 LEV�L 2 BASINSURFAC AREA = 1/ S, IV \ \ --\; Z.4 'IS I g \\ PRETREATMENT I r l GRAVEL DIAPHRAGM, \ 1 1\ �/ i l �1�- t - i li i \`'( \\\ \ / PRETREATMENT \\\ �v , �4 / IV\ !; \ // l I o / jhx , I- --II- \ 1 1 1 C L ' SA \ 0 1 �-- =-- --- \\ of/- �i --_ _- _____-___- 4' WIDE STRIP GEOTEXTILE FILTER FABRIC LAID ON CENTER LINEARLY OVER UNDERDRAIN 6" DIA. NON -PERFORATED PVC OUTLET PIPE CONNECTED TO OUTLET STRUCTURE (SEE DETAIL FOR VDOT SWM -1 OUTLET STRUCTURE) MINIMUM 12" #57 STONE BELOW PIPE PLACE GEOTEXTILE FILTER FABRIC ON THE SIDES OF THE BMP BIORETENTION OUTLET STRUCTURE BIORETENTION OUTLET STRUCTURE Return Event: 1 years Label: Proposed Outlet Structure Storm Event: 1 Year Requested Pond Water Surface Elevations Minimum (Headwater) 547.80 ft Increment (Headwater) 0.50 ft Maximum (Headwater) 553.00 ft Outlet Connectivity Structure Type Outlet ID Direction Outfall El E2 rfrl rfrl Structure ID: Culvert - 1 Maintenance Tasks Forward + • Number of Barrels 1 Inlet Bax Riser - 1 Length Culvert - 1 551.90 553.00 Slope (Computed) 0,008 ft/ft Reverse • Manning's n 0.013 Ke 0.200 Forward + 0.023 Kr 0.000 Culvert -Circular Culvert - 1 Inlet Control Data TW 547.50 553.00 K 0.0045 Reverse 2.0000 C 0.0317 Y 0.6900 Forward + 1.091 T2 ratio (HW/D) 1.193 Rectangular Weir lVeir - 1 T,,.; 552.00 553.00 elevation. Reverse .wwn•�w In transition zone between unsubmerged and submerged Tailwater Settings Tailwater interpolate between flows at T1 & T2... �+, (NJA} (N/A) Structure ID: Culvert - 1 Maintenance Tasks Structure Type: Culvert -Circular • Number of Barrels 1 Diameter 15.0 in Length 26.00 ft Length (Computed Barrel) 26.00 ft Slope (Computed) 0,008 ft/ft Outlet Control Data • Manning's n 0.013 Ke 0.200 Kb 0.023 Kr 0.000 Convergence Tolerance 0.00 ft Inlet Control Data • Equation Form Form 1 K 0.0045 M 2.0000 C 0.0317 Y 0.6900 T1 ratio (HW/D) 1.091 T2 ratio (HW/D) 1.193 Slope Correction Factor -0.500 Use unsubmerged inlet control 0 equation below Ti elevation. Use submerged inlet control 0 equation above T2 elevation .wwn•�w In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... �+, T1 Elevation 548.86 ft Tl Flow 4.80 fil T2 Elevation 548.99 ft T2 Flow 5.49 ft3/s Structure ID: Riser - 1 Structure Type: Inlet Box Number of Openings 1 Elevation 551.90 ft Orifice Area 9.0 ft2 Orifice Coefficient 0.600 Weir Length 12.00 ft Weir Coefficient 3.00 (ft^0.5)/s K Reverse 1.000 Manning's n 0.000 ll Charged Riser 0.000 Weir Submergence False Orifice H to crest False Structure ID: Weir- 1 Structure Type: Rectangular Weir Number of Openings 1 Elevation 552.00 ft Weir Length 20.00 ft Weir Coefficient 3.00 (ft^0.5)/s 5 6 BIORETENTION MAINTENANCE REQUIREMENTS SECT/ON 4 VAC 50-60-124 OF THE REGULATIONS SPEFICIES THE CIRCUMSTANCES UNDER WHICH A MAINTENANCE AGREEMENT MUST BE EXECUTED BETWEEN THE OWNER AND THE LOCAL PROGRAM.THIS SECTION SETS FORTH INSPECTION REQUIREMENTS,COMPLIANCE PROCEDURES IF MAINENTANCE /S NEGLECTED, NOTIFICATIONS OF THE LOCAL PROGRAM UPON TRANSFER OF OWNERSHIP, AND RIGHT-OF-WAY ENTRY FOR LOCAL PROGRAM PERSONNEL. FOR BIORETENTION MAINTENANCE AGREEMENTS MUST CONTAIN RECOMMENDED MAINENTANCE TASKS AND A COPY OF AN ANNUAL INSPECTION CHECKLIST. A DEED RESTRICTION,DRAINAGE EASEMENT OR OTHER MECHANISM ENFORCEABLE BY THE QUALIFYING LOCAL PRGRAM MUST BE /N PLACE TO HELP ENSURE THAT RAIN GARDENS AND BIORETENTION FILTERS ARE MAINTAINED AND NOT CONVERTED OR DISTURBED,AS WELL AS TO PASS THE KNOWLEDGE ALONG TO ANY SUBSEQUENT OWNERS.THE MECHANISM SHOULD,IF POSSIBLE,GRANT AUTHORITY FOR LOCAL AGENCIES TO ACCESS THE PROPERTY FOR INSPECTION OR CORRECTIVE ACTION Table 9.7. Suggested Annual Maintenance Activities for Bioretention BIORETENTION INSTALLATION STEP I: CONSTRUCTION OF BIORETENTION AREA MAY ONLY BEGIN AFTER THE ENTIRE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED WITH VEEGETATION.IT MAY NECESSARY TO BLOCK CERTAIN CURB OR OTHER INLETS WHILE THE BIORETENTION AREA IS BEING CONSTRUCTED.THE PROPOSED SITE SHOULD BE CHECKED FOR EXISTING UTILITIES PRIOR TO ANY EXCAVATION. STEP 2: THE DESIGNER AND THE INSTALLER SHOULD HAVE A PRECONSTRUCTION MEETING,CHECK/NG THE BOUNDARIES OF THE CONTRIBUTING DRAINAGE AREA AND THE ACTUAL INLET ELEVATIONS TO ENSURE THEY CONFORM TO ORIGINAL DESIGN.SINCE OTHER CONTRACTORS MAY BE RESPONSIBLE FOR CONSTRUCTING PORTIONS OF THE S/TE,IT IS QUITE COMMON TO FIND SUBTLE DIFFERENCES IN SITE GRADING,DRAINAGE AND PAVING ELEVATIONS THAT CAN PRODUCE HYDRUALICALLY IMPORTANT DIFFERENCES FOR THE PROPOSED BIORETENTION AREA.THE DESIGNER SHOULD CLEARLY COMMUNICATE,IN WRITING,ANY PROJECT CHANGES DETERMINED DURING THE PRECONSTRUCTION MEETING TO THE INSTALLER AND THE PLAN REV/EW / INSPECTION AUTHORITY. STEP 3: TEMPORARY E&S CONTROLS ARE NEEDED DURING CONSTRUCTION OF THE BIORETENTION TO DIVERT STORMWATER AWAY FROM THE BIORETENTION AREA UNTIL IT IS COMPLETED. SPECIAL PROTECTION MEASURES SUCH AS EROSION CONTROL FABRICS MAY BE NEEDED TO PROTECT VULNERABLE SIDE SLOPES FROM EROSION DURING THE CONSTRUCTION PROCESS. STEP 4: ANY PRE-TREATMENT CELLS SHOULD BE EXCAVATED FIRST AND THEN SEALED TO TRAP SEDIMENTS. STEP 5: EXCAVATORS OR BACKHOES SHOULD WORK FROM THE SIDES TO EXCAVATE THE BIORETENTION AREA TO ITS APPROPRIATE DESIGN DEPTH AND DIMENSIONS. EXCAVATING EQUIPMENT SHOULD HAVE SCOOPS WITH ADEQUATE REACH SO THEY DO NOT HAVE TO SIT INSIDE THE FOOTPRINT OF THE BIORETENTION AREA. STEP 6: IT MAY BE NECESSARY TO RIP THE BOTTOM OF THE SOILS TO A DEPTH OF 6 TO 12 INCHES TO PROMOTE GREATER INFILTRATION. STEP 7: PLACE GEOTEXTILE FABRIC ON THE SIDES OF THE BIORETENTION AREA WITH A 6 -INCH OVERLAP ON THE SIDES. PLACE /2 INCHES OF *57 STONE ON THE BOTTOM,INSTALL THE PERFORATED UNDERDRA/N PIPE,PACK *57 STONE TO 3 INCHES ABOVE THE UNDERDRA/N PIPE, AND ADD APPROXIMATELY 3 INCHES OF CHOKER STONE/ PEA GRAVEL AS A FILTER BETWEEN THE UNDERDRA/N AND THE SOIL MEDIA LAYER.PLACE A 4 FOOT WIDE STRIP OF GEOTEXTILE FABR/C,LAID LINEARLY ON THE CENTER OF THE UNDERDRA/N, BETWEEN THE CHOKER STONE AND THE UNDERDRA/N. STEP 8: DELIVER THE SOIL MEDIA FROM AN APPROVED VENDOR, AND STORE IT ON AN ADJACENT IMPERVIOUS AREA OR PLASTIC SHEETING.APPLY THE MEDIA /N /2 -INCH LIFTS UNTIL THE DESIRED TOP ELEVATION OF THE BIORETENTION /S ACH/EVED.WAIT A FEW DAYS TO CHECK FOR SETTLEMENT,AND ADD ADDITIONAL MEDIA AS NEEDED,TO ACHIEVE THE DESIGN ELEVATION. STEP 9: PREPARE PLANTING HOLES FOR ANY TREES AND SHRUBS, INSTALL THE VEGETATION, AND THE WATER ACCORDINGLY.INSTALL ANY TEMPORARY IRRIGATION. STEP l0: PLACE 2 INCHES OF MULCH /N BOTH CELLS. STEP ll: INSTALL PLANT MATERIALS AS SHOWN /N THE LANDSCAPING PLAN AND WATER THEM DURING WEEKS OF NO RAIN FOR THE FIRST TWO MONTHS. STEP 12: CONDUCT THE FINAL CONSTRUCTION /NSPECTION.THEN LOG THE GPS COORDINATES FOR EACH BIORETENTION FACILITY AND SUBMIT THEM FOR ENTRY INTO THE LOCAL MAINTENANCE TRACKING DATABASE. Maintenance Tasks Frequency • Mowing of grass filter strips and bioretention turf cover At least 4 times a year • Spot weeding, erosion repair, trash removal, and mulch raking Twice during growing season • Add reinforcement planting to maintain desired the vegetation ❑ density As needed • Remove invasive plants using recommended control methods • Stabilize the contributing drainage area to prevent erosion .n.:w....s • Spring inspection and cleanup +owe • Supplement mulch to maintain a 3 inch layer Annually • Prune trees and shrubs • Remove sediment in pre-treatment cells and inflow points Once every 2 to 3 years • Replace the mulch layer Every 3 years BIORETENTION INSTALLATION STEP I: CONSTRUCTION OF BIORETENTION AREA MAY ONLY BEGIN AFTER THE ENTIRE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED WITH VEEGETATION.IT MAY NECESSARY TO BLOCK CERTAIN CURB OR OTHER INLETS WHILE THE BIORETENTION AREA IS BEING CONSTRUCTED.THE PROPOSED SITE SHOULD BE CHECKED FOR EXISTING UTILITIES PRIOR TO ANY EXCAVATION. STEP 2: THE DESIGNER AND THE INSTALLER SHOULD HAVE A PRECONSTRUCTION MEETING,CHECK/NG THE BOUNDARIES OF THE CONTRIBUTING DRAINAGE AREA AND THE ACTUAL INLET ELEVATIONS TO ENSURE THEY CONFORM TO ORIGINAL DESIGN.SINCE OTHER CONTRACTORS MAY BE RESPONSIBLE FOR CONSTRUCTING PORTIONS OF THE S/TE,IT IS QUITE COMMON TO FIND SUBTLE DIFFERENCES IN SITE GRADING,DRAINAGE AND PAVING ELEVATIONS THAT CAN PRODUCE HYDRUALICALLY IMPORTANT DIFFERENCES FOR THE PROPOSED BIORETENTION AREA.THE DESIGNER SHOULD CLEARLY COMMUNICATE,IN WRITING,ANY PROJECT CHANGES DETERMINED DURING THE PRECONSTRUCTION MEETING TO THE INSTALLER AND THE PLAN REV/EW / INSPECTION AUTHORITY. STEP 3: TEMPORARY E&S CONTROLS ARE NEEDED DURING CONSTRUCTION OF THE BIORETENTION TO DIVERT STORMWATER AWAY FROM THE BIORETENTION AREA UNTIL IT IS COMPLETED. SPECIAL PROTECTION MEASURES SUCH AS EROSION CONTROL FABRICS MAY BE NEEDED TO PROTECT VULNERABLE SIDE SLOPES FROM EROSION DURING THE CONSTRUCTION PROCESS. STEP 4: ANY PRE-TREATMENT CELLS SHOULD BE EXCAVATED FIRST AND THEN SEALED TO TRAP SEDIMENTS. STEP 5: EXCAVATORS OR BACKHOES SHOULD WORK FROM THE SIDES TO EXCAVATE THE BIORETENTION AREA TO ITS APPROPRIATE DESIGN DEPTH AND DIMENSIONS. EXCAVATING EQUIPMENT SHOULD HAVE SCOOPS WITH ADEQUATE REACH SO THEY DO NOT HAVE TO SIT INSIDE THE FOOTPRINT OF THE BIORETENTION AREA. STEP 6: IT MAY BE NECESSARY TO RIP THE BOTTOM OF THE SOILS TO A DEPTH OF 6 TO 12 INCHES TO PROMOTE GREATER INFILTRATION. STEP 7: PLACE GEOTEXTILE FABRIC ON THE SIDES OF THE BIORETENTION AREA WITH A 6 -INCH OVERLAP ON THE SIDES. PLACE /2 INCHES OF *57 STONE ON THE BOTTOM,INSTALL THE PERFORATED UNDERDRA/N PIPE,PACK *57 STONE TO 3 INCHES ABOVE THE UNDERDRA/N PIPE, AND ADD APPROXIMATELY 3 INCHES OF CHOKER STONE/ PEA GRAVEL AS A FILTER BETWEEN THE UNDERDRA/N AND THE SOIL MEDIA LAYER.PLACE A 4 FOOT WIDE STRIP OF GEOTEXTILE FABR/C,LAID LINEARLY ON THE CENTER OF THE UNDERDRA/N, BETWEEN THE CHOKER STONE AND THE UNDERDRA/N. STEP 8: DELIVER THE SOIL MEDIA FROM AN APPROVED VENDOR, AND STORE IT ON AN ADJACENT IMPERVIOUS AREA OR PLASTIC SHEETING.APPLY THE MEDIA /N /2 -INCH LIFTS UNTIL THE DESIRED TOP ELEVATION OF THE BIORETENTION /S ACH/EVED.WAIT A FEW DAYS TO CHECK FOR SETTLEMENT,AND ADD ADDITIONAL MEDIA AS NEEDED,TO ACHIEVE THE DESIGN ELEVATION. STEP 9: PREPARE PLANTING HOLES FOR ANY TREES AND SHRUBS, INSTALL THE VEGETATION, AND THE WATER ACCORDINGLY.INSTALL ANY TEMPORARY IRRIGATION. STEP l0: PLACE 2 INCHES OF MULCH /N BOTH CELLS. STEP ll: INSTALL PLANT MATERIALS AS SHOWN /N THE LANDSCAPING PLAN AND WATER THEM DURING WEEKS OF NO RAIN FOR THE FIRST TWO MONTHS. STEP 12: CONDUCT THE FINAL CONSTRUCTION /NSPECTION.THEN LOG THE GPS COORDINATES FOR EACH BIORETENTION FACILITY AND SUBMIT THEM FOR ENTRY INTO THE LOCAL MAINTENANCE TRACKING DATABASE. Figure 9.16. Typical Biofilter Construction Sequence Dewberry`R Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) Q00 O_ ��O U) �O UC/) Q�0 ~ ��� p� �Z 00 vv LLI U)2Ov~ LL ZZ) 0-LL0 J� Ov i J W OOw UO w0z coo0 �Ur Z 20 o Q O1-- o U �LL SEAL SCALE o��gALT1Y °AG TT EWW V1V1 S LIC. No, 4b5 1 Ai.E�G� 10 SCALE: V = 50' I Now 0 50' 100' No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE WATER QUALITY NARRATIVE & CALCULATIONS PROJECT NO. 50097555 C9003 SHEET NO. OF �s w a ❑ i .n.:w....s •rte � , +owe wo••�vrw f �.... .wwn•�w RPO r1�W11R �+, Mf Wa•avw Vewobw .�rwou •s+a aw ue�anw. Oso,-,� ra,wa ,r 14, rim r. .r..,.,,.. �. M � w &MID �osavtfm o D_wr PlI+M RA 01V 1L& OCMrM•A w � wM. � urs ��Ml �iR/�MI17Uw Marl POR O 11WIl ON PLAWDOM Urt]111111111111i1tAMN WILL LOOAT11111110 AT ■OT7OIM Or 01tAVEL.1AW NT8 Figure 9.16. Typical Biofilter Construction Sequence Dewberry`R Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) Q00 O_ ��O U) �O UC/) Q�0 ~ ��� p� �Z 00 vv LLI U)2Ov~ LL ZZ) 0-LL0 J� Ov i J W OOw UO w0z coo0 �Ur Z 20 o Q O1-- o U �LL SEAL SCALE o��gALT1Y °AG TT EWW V1V1 S LIC. No, 4b5 1 Ai.E�G� 10 SCALE: V = 50' I Now 0 50' 100' No. DATE BY Description REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE WATER QUALITY NARRATIVE & CALCULATIONS PROJECT NO. 50097555 C9003 SHEET NO. OF E X C W 1 CHANNEL PROTECTION ANALYSIS 2 1 3 1 4 THIS PROJECT OUTFALLS INTO A NATURAL CHANNEL DOWNSTREAM OF THE EXISTING GOLF COURSE POND. ENERGY BALANCE WAS ANALYZED AT THIS POINT TO MEET CHANNEL PROTECTION CRITERIA. THE PROPOSED BIORETENTION BASIN AND PROPOSED DETENTION BASIN WERE UTILIZED WITHIN THE OUTFALL'S DRAINAGE AREA. DUE TO THE LARGE AMOUNT OF OFFSITE THAT THE DETENTION BASIN RECIEVES IN BOTH EXISTING AND PROPOSED CONDITIONS, THAT ADDITIONAL AREA AND FLOW WAS ROUTED /N EXISTING AND PROPOSED CONDITIONS. SEE PONDPACK SCHEMATICS ON THIS SHEET. FOR THE OUTFALL,THE MAXIMUM ALLOWABLE I -YEAR DISCHARGE PER THE ENERGY BALANCE EQUATION /S 5.93 CFS. THE PROPOSED I -YEAR DISCHARGE IS 4.3/ CFS. SEE THIS SHEET FOR ENERGY BALANCE CALCULATIONS. SEE SHEET C9.05 FOR THE I -YEAR ROUTINGS. PRE -DEVELOPED DRAINAGE AREA MAP OUTFALL DRAINAGE AREA (AC) Tc PATH (MIN) WEIGHTED CN - SHEET LOWS SITE AREA 1.95 7.4 79.6 ' "Tt = 0.06 -MIN- ; ; OFFSITE AREA 2.50 9.7 76.8 i i`, V - v DETAINED OPEN DITCH \ I 173.0'_ Tt_ 2.28 MIN , Ices PIPE FLOW s \ •� / \ \ L = 165,0' \ I ' I Tt = 0.00 MIN A. \ 4 s� \f �V - 'OPEN DITCH L 1760 SITE AREA !ll '- t \\ ail//Tt-/.56 M/N\ AINIIG TO OUFALL PIPE FLOW \- - �- .• I \ Tt = 0.00 MIN Ir � \ .•. I , ,�,_� 1j� v � mai,,, \ I I , //,/ /!„ 1\AAI V � �v � -, � -,�_r � 1 ,� •� it � I� 1 II I I \ / � /1/ II � i `" �`� �\ ---�� POND\` \. 259.0'. \\ 11:1 Tt = 3,00, MIN / l 1 ��----- i �\ I\, �1�Ill /b�II( Ir Iffl\\ - _-=L=114,0'-_ '®� I1 \ ' / \\\� iil i'i'//J % / n !\/ 1 \ \� - _ _ -Tt _0.00_ MIN--- \ FLOW, _ =- \\ L = 34.0'/ _ - \\ ,OPEN DITCH �- Tt=0.00 MIN' _ _ ------------- L = 744.0' �= �; _ _ , = OPEN DITCH T t = 4.74 MlN - - - / =L 34.0' lull I / / / / / / / j \ 11 IIII l �l/ /// ^ \ \ \ \ \ 11/�// //// / 111 /////' /:�, / ///�////////// //,/ // I I I / / / �, r / / / 11 11// I ✓ilii l I ' l l /'' IIII //l 11 l l 1 /I I l , 1 I / l / �: i \ \ \ l \olI III ll"Of %l- / / // l// /// l l/l/l /l /I / / Il I I I I /l / 11 11 �// Ill' /"ll l/ / �J I l 1 II 1 I /�. , / .� - _ -- --� /' / , // - / / //I l l I• l l �l /l 111 / / l l l / I / I � ` / / �-- JPIPE FLOW aL =64.0' :dad / �� , / Tt 0.00 MIN, i �-- .- % / // ` III I I I I � IIIIII III 1//1//// // /// �, / „• / ------ 1 L 1� OPEN vDICH' ' ° l / III f I I I / . III / / r/ / / / , _ / -L =303,0' Tt = 3.78 IN 7 I wV I IIIIII VIII 1111 I I II , ! , /, , 1 / dIl Il I I I 1111111 /ill IIII III I, II I l s / / / � / �/ / »�I I N A\ \���//\\ \ \\\ \\\111,\\ \\ \\\\ 1\Ii111111 , 1 \) 1 I I II Ill\I\I\I III I I� I III // \ /^\ �• � r(\ �$'r''"`"�? \\ 1 � =, -\ SHEET FLOW L = 49.0'-t' Tt=0.66 MlN \ \\\\ \\\�\\\• �\ 1 / ,--- - --�- POST -DEVELOPED DRAINAGE AREA MAP OUTFALL DRAINAGE AREA (AC) Tc PATH (MIN) WEIGHTED CN\ _ SHEET FLOW BIORETENTION 1.60 5.0 8/.5 Tt = 0,06 SITE AREA 0.77 7.4 83°6 i v, l OPEN DITCH �L 173.0' DETENTION II \ = 77.4 % ;®`Tt = 2.28 MIN BASIN 2.86 8.9 I i PIPE FLOW s \ •. \ .,I L = 165.0' I Tt = 0,00 MlN \ \ I I Irl -OPEN DITCH AREA SITE L - 176.01-_ \ �/ • / r Tt = 1.56 MIN `DRAINING TO'-0UFALL r` \ - \PIPE FLOW BIO ETENTi67Y v BA l ; DA \ - - - I \ Tt, = 000\ MINS \ \ \ 3`_ POND Tt = 3.00 MIN\ -_ Tt = 2.46 MIN _ 1 1 / -_ _ _ - - -- - =PIPE FLOW � _ _- / / 1\ P I f1\lII\�;/ 1111"� IIII � ,/i��l l / /��,� //If•�I1r I \ --- -=L=114.0'-- �, _Tt=0.00_MIN PIPE FLOW - P` L = 57,0' - --- \- 1\ OPEN DITCH // y - =OPEN DITCH= / ,I - L = 495.0' 34.0' .° I I / ' / Tt = 3,84 MIN /_ _- i -Tt_ 0.48_ b � - -_� � � � � \ \ / /a/ / , /, ,OPEN DITCH \\ ,� ,--\ lull _ _ /� /�//// G - -\\�` ////'/ /L = 38.01/ Tt - 0.60 MIN / /IIF- ILL II I I I I ' I I /!0 / Ill 'II1 l'Iffillllllllllll I I II / / \y,�/ // / PIPE FLOW aL = 64.0' If 1 1 1 I 1 11 1 / l / Tt 0.00 MIN/ 'I Ill IilIillirll l /��l - ' A ��- / I11111111 1111 11j lI/ 1 r / / / / ,« I II1I I I I / / / 1ljlllll,'Il;ll1110 llll);Ill/a, OPEN DITCH -L = 303.0' D T E / Tt = 3,78 MlN/ / III � I IV (IIII\ FI ,x. -\�_- // \ \ SHEET FLOW 1 I L=49.0' Tt = 0.66 M/h- sroa.cre�3 \ I l i o I I I \ 7 �/�/ 1 1 l l l l l l l) I I / I I I I �\ 5 ENERGY BALANCE CALCULATIONS UVA Boar Head's Road outfall. I Engineer: HG Albemarle County Channel Type: Natural Checker: MT Dewberry STEP 1: Determine the Pre Developed, Forested, and Post Developed Conditions within the disturbed area and the offsite area draining to project BMPs. Pre Developed Conditions Forested Conditions Post Developed Conditions Offsite Conditions Weighted CN = 79.6 Weighted CN = 69.5 Weighted CN = 82.8 Weighted CN = 76.8 Area (ac) = 1.95 Area (ac) = 1.95 Area (ac) = 2.03 Area (ac) = 2.50 P (in.) = 3.04 P (in.) = 3.04 P (in.) = 3.04 P (in.) = 3.04 STEP 2: Determine the peak discharge for each area. The total predevelopment discharge combines offsite and pre developed conditions. Pre Developed Discharge Forested Conditions Discharge Post Development Discharge Offsite Conditions Discharge S 2.6 S 4.4 S 2.1 S 3.0 Ia 0.5 Ia 0.9 Ia 0.4 Ia 0.6 Q (in) 1.3 in Q (in) 0.7 in Q (in) 1.5 in Q (in) 1.1 in Volume 0.204 ac -ft Volume 0.116 ac -ft Volume 0.248 ac -ft Volume 0.227 ac -ft Total Total Forested Peak Predevelopment Discharge 5.59 cfs Discharge 7.22 cfs (From PondPack) (From PondPack) STEP 3: Calculate Adjusted CN value using Runoff Reduction provided in BMPs BMP Runoff Reduction ft3 ft3 Qpost without RR = 1.5 ft, Qpost with RR = 1.5 ft3 Adjusted CN = 83 ft, Total = 0 ft3 STEP 4: Calculate Qauowable using the energy balance equation. Only apply the improvement factor to the disturbed area. Energy Balance Equation: QDeveloped 5 I.F.x(QP­ Developed x RVpre-Developed) / "Developed Improvement Factor 0.8 Qallowable < [Total Predeve lopment Discharge (Offsite Volume + (Improvement Factor xPre- Deve loped Volume) / (Post -Development Volume +Offsite Volume)] Qauowable 5.93 cfs STEP 5: Calculated Maximum Allowable Peak Discharge. Maximum Allowable Peak Discharge = Maximum (Qr real, Qallowable) Qfoo,a = Total Forest Peak Discharge x (Forest Volume + Offsite Volume)/(Post-Development Volume + Offsite Volume) Qf-t 4.03 cfs Maximum Allowable Peak Discharge 5.93 cfs STEP 6: Ensure Qpe bdeveloped is less than the Maximum Allowable Peak Discharge QposPdeveloped (from Pond Pack) 4.31 cfs Channel is Adequate PRE POIV DPACK SCHEMATIC SITE AREA D) OUTFALL POST PONDPACK SCHEMATIC BIORETENTION DA BIORETENTI O 1 Site Area By SITE AREA rAINED SITE AREA BYPASS DA DETENTION B. D. DETENTION Ir"A OUTFALL DETENTION BASIN OUTLETSTR Dewberr y Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) 0. Q LU oo O_ �w0 U)< I- 0�O Uc) Q � �� D~ ��� O� �w 00 vv �� Ov~ LL zZ) �LL� U JOv J W OOw UO w0z m 00 r- ( z 2O o O O1-- o U 0� LL SEAL SCALE - o��gALT1Y pAG 1 0 TT EWX31 tG�S Lic, No, 465 1 �S Ip Ai.E�G� 10 SCALE: V = 100' now 0 100' 200' No. I DATE I BY I Descrlptlon I REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 20/8 TITLE CHANNEL PROTECTION MAPS AND CALCULATIONS PROJECT NO. 50097555 C9.04 SHEET NO. OF 1 7 - d F F C DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O �w0 u Q � ��� 0�O c) ::) 0� Z� O�e 0z ADO UV I--- Lu Ove ,� U� LL U J� z _j Lu Ow 00 W0 Z Om U HZ o 0 UO� o O � U LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE LV L No. DATE BY Descrlptlon ISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE CHANNEL PROTECTION PON DPACK ROUTINGS PROJECT NO. 50097555 C9005 SHEET NO. OF E X C W 1 FLOOD PROTECTION ANALYSIS 2 1 3 1 4 1 5 1 6 THIS OUTFALL UTILIZES THE PROPOSED BIORETENTION AND DETENTION BASIN TO MEET FLOOD PROTECTION. THE ENTIRE DRAINAGE AREA TO THE OUTFALL WAS ROUTED. FLOOD PROTECTION IS MET FOR THIS PROJECT BECAUSE THE 10 -YEAR POST DISCHARGE OF 86.11 CFS IS LESS THAN THE 10 -YEAR PRE DISCHARGE OF 86.36. SEE SHEET C9.07 FOR THE PONPACK SCHEMATICS AND ROUTINGS. A LEVEL SPREADER 1S PROVIDED AT THE DETENTION BASIN'S OUTLET PIPE TO ALLOW FOR WATER TO SHEET FLOW TO THE NATURAL CHANNEL AT THE OUTFALL. PRE -DEVELOPED DRAINAGE AREA MAP OUTFALL DRAINAGE AREA (AC) Tc PATH (MIN) WEIGHTED CN g / _— un — SITE AREA 1.95 7.4 79.6 Tb I / OFFSITE DA 17.00 9.0 79.4 ymp /'�� / "a�� •-- �_ ;' �\ � \\ �/– � a'I = weitalcroro°R� \ ° � pp p I � � _ "c� – � \ – – – – – _ _I �. I I � • ill �«I ii;� `�_ � �\\ I / I «�—,•_,�x� I I 1 '. � 6 5902-4- \ \ _P° \ \ \ \ � _ I \ (/~t� `� \ 59D2-04-06-6 \ l rIAP 5902 -04 -OB MP 59D2 -04- I De -a QR – ��-- 1 b '�– / l -- / / ALL- llllll\1Tilll l F \\\ I 1 •� / \ \ \ 1111 \ 1 / �� – -1 I 1 I I I l / / / /"` - /' 111 \ �/// 11 l%//lIl ,/ /' / _^\. � I I�\\ ---` \\ IIII \ \ \ \ \ \ \ 11 I'g%///// // /// lr III 11 / t / / l l l ( I ) / l // i / \ \\ \ :tel I \ – \ j1 11 l/ II 1 / / / / � I --, \\ .1 `\ I // /1 I.I /\ IIII 1 , l/ 11 l/ll l// 111/l /l I I I I / �–_\ J/ / II° l /l /l // ---- I / ,III I° l � l l //,�/ l/l/l / /l, / I / / l / J JI / /I I I I �' � 1 J------- 01 – – / � I 1 � ` , \ \ \ \ , � � \\11111 �• � 1 1 \\ \\IIII l J,/ / /'I , JIII II l 111 V/AA(-?L –APPA/ \ / I l �1 � l I I l , /° I I � I / IIIII II 11 I I lI 1 / / / / / :.o g,ia�"✓os�i-mov --� / / � \ ,� / / � l I I All / / / IIIIIIIIIII IIIII IIII 1\\ 1\\\\I 11 1 I / �// �rooG�r i �s m�\ a \ 1 •Ill/!/ /J \\\\\-- \1 111/ l ill \ – l llllll l / � / �` � / / / 1� 11�gllllll I I IIII 111 III 1 II ' \ ,«.,J ` �✓ \ / t;/ I I/ /�// / l /!l \ \ \ \ \ '\ [�\vl it _ I POST -DEV ELOPED DRAINAGE AREA MAP OUTFALL DRAINAGE AREA (AC) Tc PATH (MIN) WEIGHTED CN / _— ui — SITE AREA 0.77 7.4 83.6 BIORETENTION 1.60 5.0 81.5 r _ DA IIS, III I P\I �. \ � h / /' '� --_, DETENTION / BASIN DA 2.86 8.9 77.4 OFFSITE DA 13.80 9.0 79.8 \\, \\ %\ - \ TOTAL OUTFALL DRAINAGE AREA ter, -l1 --- =_1 / \ r \ � _ cuss• 'o •� \ "a, I .® \ \ _ �= I rMP 59Dz-o4-oe-1 01s •--�„� IIII ' ''✓ � o.. \ \ � \ \ \ � YY / \ 5902-4-8- O 7MP 59D2 -04 -OB -6 TIAP 5902-o4-oB-7 i • E. , I I / I/ �) i ' \ _ — _ _ _ \ •' l \ \ \ '.a & TUP 59D2-0,_08 At 06 8 RC\T\t IV\I qIv .d I I N�• I � -- \ IIII � 1 4 I � \\ � \1 � 1 \� \ \\ \��_ 'v -- N �/- /,"-- ,\�i–\\� JIII t= __– / _(J\\ �\J\I\I\\ ~'®�II\'' \\�\" /'i%),'�/ �/ Jai'' �'� I , I 1 \ __ -L--_ \__ \\ e• \�– e –I /'/ / \ '/ �/ _" _ ASI qc \ "€. /-- 1 I 1 � –'y/ ////// -- `, �\ \o\ I I � "/ / / / ' � «e. ✓/ _ \– \ I,\l \\\\ \–, «I � X1111 0, s« 11 \ \ \ I � \ \ \ 111 / � IIIII l % / :�, , // / //,/ / / / / // / / / �/ / 1 I I I , I / 1 1 / � ,/ , � \ \ �, \\\ ) � _ �'�_/•J 1 III 1 111 //Ill/lllI , I l l l l I I_ I I I I I I I � IIII I I / / / / / / / / /\ / , , / � / � / _ w l _ \ � / � �J✓ / I 1 / l 1111 1 II S. s>s? ° '��F.°s'�3`��s ///IIIII II IIII\\ \ \ \ I 1 \ \ �\ I ' 1 .a // / – _ \ \� > //Ill 111 I III \\\ \ it ll r1m,'l l I \ \\\v\ °\ / � I �\ / / I )//// Ig I I IIII 1 IJ 1111 I III ,� � � 1 \JJ 1 1 �–�✓ \ 1\ _ /// �"�/// //�(\//I , // �\\\� \\ \ I I � ( \W � – • " _–J' �` � �\ ` _ \ \\�� – '�–`� , 41__���Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) Q �p O OLu �vj� �O Uc� Q �0� �~ O� 0�w 00 Uv �� 2iLL LL z U J0� OU J W OOw UO Lu0Z m o0 �Ur Z 2'Oo O OF— o U 0� LL SEAL SCALE o��gALT1Y Ok 1 0 11 LII Lic. No, 465 1 0 �S Ip Ai.E�G� 10 SCALE: V = 100' 0 100' 200' No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE FLOOD PROTECTION MAPS PROJECT NO. 50097555 C9.06 SHEET NO. OF AI IIS, / �= I rMP 59Dz-o4-oe-1 01s •--�„� IIII ' ''✓ � o.. \ \ � \ \ \ � YY / \ 5902-4-8- O 7MP 59D2 -04 -OB -6 TIAP 5902-o4-oB-7 i • E. , I I / I/ �) i ' \ _ — _ _ _ \ •' l \ \ \ '.a & TUP 59D2-0,_08 At 06 8 RC\T\t IV\I qIv .d I I N�• I � -- \ IIII � 1 4 I � \\ � \1 � 1 \� \ \\ \��_ 'v -- N �/- /,"-- ,\�i–\\� JIII t= __– / _(J\\ �\J\I\I\\ ~'®�II\'' \\�\" /'i%),'�/ �/ Jai'' �'� I , I 1 \ __ -L--_ \__ \\ e• \�– e –I /'/ / \ '/ �/ _" _ ASI qc \ "€. /-- 1 I 1 � –'y/ ////// -- `, �\ \o\ I I � "/ / / / ' � «e. ✓/ _ \– \ I,\l \\\\ \–, «I � X1111 0, s« 11 \ \ \ I � \ \ \ 111 / � IIIII l % / :�, , // / //,/ / / / / // / / / �/ / 1 I I I , I / 1 1 / � ,/ , � \ \ �, \\\ ) � _ �'�_/•J 1 III 1 111 //Ill/lllI , I l l l l I I_ I I I I I I I � IIII I I / / / / / / / / /\ / , , / � / � / _ w l _ \ � / � �J✓ / I 1 / l 1111 1 II S. s>s? ° '��F.°s'�3`��s ///IIIII II IIII\\ \ \ \ I 1 \ \ �\ I ' 1 .a // / – _ \ \� > //Ill 111 I III \\\ \ it ll r1m,'l l I \ \\\v\ °\ / � I �\ / / I )//// Ig I I IIII 1 IJ 1111 I III ,� � � 1 \JJ 1 1 �–�✓ \ 1\ _ /// �"�/// //�(\//I , // �\\\� \\ \ I I � ( \W � – • " _–J' �` � �\ ` _ \ \\�� – '�–`� , 41__���Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C) Q �p O OLu �vj� �O Uc� Q �0� �~ O� 0�w 00 Uv �� 2iLL LL z U J0� OU J W OOw UO Lu0Z m o0 �Ur Z 2'Oo O OF— o U 0� LL SEAL SCALE o��gALT1Y Ok 1 0 11 LII Lic. No, 465 1 0 �S Ip Ai.E�G� 10 SCALE: V = 100' 0 100' 200' No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE FLOOD PROTECTION MAPS PROJECT NO. 50097555 C9.06 SHEET NO. OF 1 9 - d � F DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) SEAL ' F,ALThjop O i TT EW SAS Lic. No. 465 1 Ip AL' C SCALE LV No. DATE BY Description REVISIONS DRAWN BY TYR APPROVED BY DIM CHECKED BY MCT DATE MARCH 2018 TITLE FLOOD PROTECTION PON DPACK ROUTINGS PROJECT NO. 50097555 C9007 SHEET NO. OF 1 E X C W 2 ST ORMSEW ER DRAINAGE AREA MARS 3 1 4 1 5 1 6 -- - �\ � /° �III'IIIIr I I \ I I" \ �_ ^\ \ \ \-_ �� \ \ y' l°: cbv• �"'\ \ /� � 535 \ \ \ I \ \ `Lcp CD ?) \/ I❑ /�-x/�-�--xV' k--_4 = / -/sxI� Ira/x el ux -o xIaIx - aoe/-�-xl "\x_e- -�/-°n.e-. I ---a\ °---\k.-_Ax_ vi�c- e -u\ 5m5Z=\ -_-eras- x�-_M,y-��J�--'�--\a- kw/iG-/ �`-�� 7 \m_I / -\ q/7' _�-IrI \I���I \�I /-/ - j/ I 5\ -I5i/ 1\II0/'�\-/I \ I \ I �I1/j II /5 \- _JIIl I � -=I1\\ I I_�sI\ ' I�� �fI\ira-a/'l1IIIl,� ^IIII.` I'/S1lI -/I III\ I\I\;I1I1I\\�I1III\I-III1II\1\III11I \\\ I II�,\-�I1III11\\I1\ II�JI\ \I 1j1I` III°11.1I I -I lI III�1c\\-I11/ OIAr\1II 1 "I'I/Ir1I \ vI-1 `aIII \ /aNlI i j'' Iu %� I(�1/�teI 1/I1.IIt IIIII _/1 1 (!\I\\ II \I�I �III I,II lI\ I_1II 1\�l'�I11\11--1D1�\'f_ \�1'/\ \ \�� l\� \- \I�j \�\ \ \--\_-- �-\ \_\\-\ I� -\'-� /`-\ �J _- /_- \-�x\- --\ //� -_- \\ ��. C \\�I I \- \\\\\ I\ \ /1\\\L\I \\\ \U \\n\\\\\_ \\\/\\�\\/ /\-\�\ \\\ \, 1 \�\\ / \ .\\\_\ /\\ \ / �\\\\\III I \ _I\ \\ �I\\\\IIII\/ II \ I j �- \°/\\ \ II\ /I 1 I \\/ �/' \\\\✓\�VI \ �I/11 \I �/-\ �\\I�\ � III - I \ I \ �\\\/'� II\ �/ �I-� �\/ �\I\I/I�I �� I /-\// \I\ \I\//I \/ �\� �I\\-I/ �I\/ \� /_1�/I�//'\ \ \/-'�\ �\�/1-/\//_ 11\\\ /I '-// I l\/1 -1 \ / /\_ \I/1I'I \ / I \- /I I -- / -\\-\�/ I/-�/ //\I s`\-�//\ w-� / / \�\\/1 -/ _�\/\/I\/\ _\\-/-_ /-' \\� _- \\\`/ _ --/-\--_--_ \\\\ \-/-/\i\ \ II`--�\ -\ ----_�//- =\\�_`\ � -\-�_-_ `\ \�=�_\ p-/�\F�\� ;/\�-�1-�\' ( \I /\\5s\ �i-_\�� \/\\�� \-�\ 5- \_ ��-\-�-\-//\�=��-\\ \_s� _-��/o\\_-�_\\\\/ \�\ �-,-/_\--/��- -\ �_ ��\ \,o - ��/ \\� �\/�5 / ,�\ -\�\5/T`q� 0�-, _ _'_ \�-\ \�/'__-/`\��_--\\_-�-/-_\ \ \ �\-\_� \---_\___ \�\- �\-\/ -,-�-al�/\\-\ -_\__-,- `\' ,��-\-�--_ - \,�_\\�\\= �_-o-`\�\\�\\`� \-�\\\1\ �-�\- -�\- � \-\ � _-� -\\\- �_-\\-��\�\ \\�-_- �\�_�\-�� \\- \\�__\ ,- \_\\ \\--_ -�--\\_\ \�-` \ \_--\-- _�`-\\ __-__\-\�\�I\��-�\_\ \�--�\\_-\�_-- ��\\\�_- -_�_\-\ \\\�-\-\1_/ -�_\--_ _\\/ \c -I-\\ -�--/� � _\ _-\k- --\\\\ \_- �_ �-\\\\\\ x\ -\_�--\_\\\- - ---\x-�\\\i � k_��\\(_--_ \\\-\\\__ \\--_\-\�_- \ _�\_�\x-. -�\k \-\\_��\�\__�_�--/�\\\ __\_- -\\--\_�,_ \-.k�_-_�� ---__\ \- \-\\\_-� -\--\ \\--� \�_ ---x\- k- �ms -_� _\--\\\�- -- \\---\--x�-\\\ -_\-- ❑� \ \\- ----\--\\\ l� -___--❑-_-x�/�x-___---)-=\\ --\-_--�\_� -❑\\�-� R- xw---\u--\k\- - -- ,-- �\-"-\--\- 0_--\-�\ --\\---��-x-. --�\ \--x\❑\ -- --J-- _-``-�-�-----�- 0-��-//\J�-\ -0 ❑- 1-\-_ -i- - ---\ /�- --_�--_k -_-__ �--_' - _P- ❑ -' \- --� - ----__8�- --'_\-- - /-- �-\/-_\\-\ �i_\\\ _\\❑- --\�- _ I/ � /-0 ' 1�\ 1-5/6 30 ------------ - - - - -- \� 55 734(PLwr) sas sas 7'17'03 W ---------_\ 540 550 -570 - ------- - 545 555 --- - - - - - 550 0.4 _--__ sss ------------------------ b --- ----------- 0.6 ----------- \ -- - - - - - -_ ----- - - - - - _ - --------sso_\ 1 1_ ------ -- ----- - - - ----- ----- ---- __ ----- ____-____-----_____- ---- 565 r/ - - - -- - - - - -- - -- --- ---------- q �\ 1 1'i//it Y \ \\ X \ o I ses® \ / 1141- 585 6 sss 57o t- - -- \_-- \C ' A/// � oR/- - � T// / JSS° _- - - - o6 11-6 OLC-RSt OFFICE o 9 o 00 TE 4011 I o -- II '�- I I I; I I � I �\ / � _' / / \\ I I I I I \ \ \ / �' -' / \ \ \\ I \ -�- \ � I I � I\�\� � � r� \�� � \ 1 I ❑❑ ST ORMSEW ER CALCULATIONS I ii' ►_:� Dewberry Storm Sewer Design Computations LD -229 Hydraulic Grade Line Computations t.�., '�•�'� Dewberry PROJECT: Boar's Head Connector Road COUNTY: Albemarle County LD -347 DATE: OCT. 2017 PROJECT: Boar's Head Connector Road COUNTY: Albemarle County ENGINEER: HCG / Dewberry Consultants LLC OUTFALL TO STRUCTURE: 1-6 DATE: 1 -Nov -17 TOTAL WEIGHTED RAINFALL INVERT ENGINEER: HCG / Dewberry Consultants LLC OUTFALL TO STRUCTURE: 1-6 AREA RUNOFF INLET INTENSITY SATURATION FLOW ELEVATIONS LENGTH DIAMETER MATERIAL MINIMUM MAXIMUM FLOW St'IS-1 Inlet FROM TO "A" COEF. "CA" TIME FREQUENCY "I" FACTOR Q (FT) L SLOPE Do COEFFICIENT CAPACITY VELOCITY VELOCITY VELOCITY TIME Flow Entering INLET INLET (ACRE) "C" (MIN.) (YR) (IN/HR) Cf (CFS) (FT) (FT/FT) (IN) n (CFS) (FPS) (FPS) (FPS) (MIN) REMARK INCR. ACC.* UPSTREAM DOWNSTREAM (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22) (23) 1-1 1-2 0.47 0.69 0.32 0.32 6.64 1.00 2.15 559.09 558.80 51.0 0.006 15 0.013 4.87 3.86 3.0 10.0 0.22 5.00 10 1-5 1-6 1.60 0.50 0.80 0.80 5.76 1.00 4.60 550.58 550.20 54.0 0.007 15 0.013 5.42 4.97 3.0 10.0 0.18 (17) 8.30 10 (19) DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C Q pp 0 >- Cf) U) ��� �0 Ucn 0 �e 0. Z ADO UV �w � U J3: zz:) J LLJ O w(-)0 0 W Z 0m U ��Z 5 op U � o O O� U LL SEAL - �'- V,p►LT1Y0A 11 Lic. No, 465 1 ,; Ip AL SCALE SCALE: 1" = 50' 0 501 1001 No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE STORMSEWER MAPS AND CALCULATIONS PROJECT NO. 50097555 C9.08 SHEET NO. OF Hydraulic Grade Line Computations t.�., '�•�'� Dewberry LD -347 PROJECT: Boar's Head Connector Road COUNTY: Albemarle County DATE: 1 -Nov -17 ENGINEER: HCG / Dewberry Consultants LLC OUTFALL TO STRUCTURE: 1-6 St'IS-1 Inlet JUNCTION LOSS Inlet Water Flow Entering Inlet Station Outlet Water D° Q° L° Ste% H Final H Surface Rim Elevation System Shaping S V° H° Q, V, QV; V"/2g H; Angle Ha H, 1.3 H, 0.5 H, Surface Elevation Elevation Through Drop Provided? (Enter Y or N) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (CFS) 1-5 551.200 15 4.60 54.00 0.514 0.28 4.97 0.10 0.00 0.00 0.00 0.00 0.00 0 0.00 0.10 0.12 N.A. 0.40 551.60 552.50 4.60 N 1-1 559.800 15 2.15 51.00 0.112 0.06 3.86 0.06 0.00 0.00 0.00 0.00 0.00 0 0.00 0.06 0.08 N.A. 0.13 559.93 562.50 2.15 N DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C Q pp 0 >- Cf) U) ��� �0 Ucn 0 �e 0. Z ADO UV �w � U J3: zz:) J LLJ O w(-)0 0 W Z 0m U ��Z 5 op U � o O O� U LL SEAL - �'- V,p►LT1Y0A 11 Lic. No, 465 1 ,; Ip AL SCALE SCALE: 1" = 50' 0 501 1001 No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE STORMSEWER MAPS AND CALCULATIONS PROJECT NO. 50097555 C9.08 SHEET NO. OF 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J0�Ov JW 0UO WIZ m �oo 0 OO 0O c:) U r LL SEAL o��gALT1Y °AG O TT EW�l tG�S Lic. No. 465 1 10 C SCALE SCALE VERTICAL 0 5 10' SCALE HORIZONTAL 0 25' 50' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE STORMSEWER PROFILES PROJECT NO. 50097555 C9008A SHEET NO. OF 1 E C W 2 DITCH DRAINAGE AREA MAPS 3 1 4 1 5 1 6 `535 GG \\\555\ 5 555 --- ' '_ \ �ss 5 - -------- - - - - -- - - / 5555 \\ ( \\ \ \ \ \ \ \ \ \ \ \\ 30-� 0.04 01 \\� \ `\\ _ -__-_ _���- �\ \ \ \\ \\ \\ \\ \\\ \\ .`{7 \\ _ 0 20' WATER - - _ - - - � 095 - _ � \ \ \ `P 545 \ /' /' i X535 ----- -- --- - - / \ 0.03-- _ 540 550 -Al \ ------------- I\ ==__--_=`\_\\\\_ \\\ \\\ �\\\`\�\�\\\ \`\\ �\\--'/�' /////X545- -555 \-550_ �\ sso I 2-1 I - ' ° \ -�-\ \ / / , - \ \_ -- _------____-----__-__ I 0. \ \ / �_ ---- - - - - _ ---- -555 \ \\ \ `--------__-_-------',, �i -_-- \\\\\ \\IIIIIII' I I ,5 - \\\�\\ J /l _-- \\ \\ `-- ----------- ---__-/i ,-- ---_ 1j11 0.6 \ I \ _ --\__---__--------------------------_-_-------- ---- - - - -- _- --__-_ \ \ --__------- - - - - ---- - - - - ------_--- \ \1 _-_--------- _--_--_'''- \ \\\ \ \\ �\_------------------_-__-- - ' ---- -- - -- -� _ \ \ / / - X565-\ \\\\\ \\\\ kA I �- ( - --- ------------ \ \ -- \ ------------- - - / / % - \\ \\ \\\ ��S�I\ �I� I so\ \ \\\\ \\\\ \111 Illy- / "/, \\ \ \ \ \\ \ \ \\ 11111 1 \ I �/ ////� - ``------------------ \01 - -------------- - - - - -- - 11 l 11 1\\l 11111 I i l�lll / \ / /\---3' ---- -- - - -- - \ /- \\ \\\ /- -- -------------- - - - - -- / --- ---- /-- I / // I IIIIIII\ \ _1 // / / _ \-_j 0. .39 �50 \ L I I/ �_- -_--� I \\_� ' / � \ � \\ \ --- � \ \ � �_\__` � � __- o x x x-- ,.--x�❑ o J ❑ ❑\\❑ ❑ r�\❑ \\ � \\ 1111\ \ j-�' // / \�� v -v _Roos o® \\ 3\ - I / L-5as \\� •% I 1111\_ \ � \� \ ` ( a I ilIi \\----- 1\ --------/-/---L�57o 5 �- \� ----\ \\ \ - CARTS Fil- /,--_GOLFCOU� --_\ J SFS000S op - OFFICE A o i 111 \ o 9�2en " / - \ o a q Wa6EeLIN 1,-- �-` o /_- I 1 I; I I � I �\ / � _' / , \\ I I I I I \ \ \ / �� -' / \ \ \\ 1 \ __- \ � I I � I\�\� � � r� \�� � \ 1 I ❑❑ DITCH CALCULATIONS 4� Dewberry ��_- Dewberry Computations Ditch Computa LP -265 PROJECT: soars Head Connector Road DATE: 11/21/2017 DITCH IDENTIFICATION: 3-1 TO 3-61 DITCH TO STR 1-5I COUNTY: ENGINEER: Ditch Computations LD -les Albemarle HCG / Dewberry Consultants LLC CONNECTOR ROAD Ditch Computations LD_26R 1r� N PROTECT: 11car's Head Connector Road COMM Albemarle Ditch G Hvicivaulllu PROJECT: Invert Frm station To5ta'-cn LTUpstrcarn fbwrstrcam DATE: 1161+2017 Moa I {Maes+ ENGINEER: HCG /Dewberry Consultants LLC C 0.3 1W CA Total CA Tt {min} SO yr i Iln/hr) 2yr i (IVhr) 10 yr Q (cis} 2yr a (Cfs) Bottom B (ft) Depth Y M1 Left Slope (HM Right Slope (HM Uning Type Lining Width (ft) n DRch Curve? R,(ftk DITCH IDENTIFICATION: 2-1 {DRC" TO STR 1-91 l0Y Depth (ftl low Velocity (ft/sec) 2yr Depth (ftl Corrector Road 1ractive Fottt"C .1 Llning Adeg7 IMaxV1 weill,011011110 000-0000 DU,,b D1 567 00 551.Ub 0.180 070 0 330 0.50 MID 0.30 0.390 Ditch Geometry 500 6.64 5.90 2.59 2.30 Hiril-Fic; 1.00 b 00 5 DO Invert Area C Area C Area C Inrr Tool Ti: low 2yr SOw 2yr Bouorn Depth Left Richt Lining Lining n DiLch Dinh Soy 10 yr 2yr 2yr Tractive Lining UrvinK Freer eapaeitp From Station Downsrreern to Station R1 1 0.9 2 0.5 3 0.3 CA CA 003+16.00 003+66.00 559.40 557.50 i i Q Q 6 Y Slope slope Type Width 5.70 Curve? Slope Depth velocity Depth Velocity Force "V Adeo? Adea? board Adeti? 0.60 Upstream lacresk . _ - (acres YES (acres) 003+6+6X0 004+16.00 $57.50 555.40 0.613 OL90 (min! {in/hrl (iflAr) Idil 101) (ILI (ft) (WV) III/VI 3.71 (rtk 0110 Ra {ft) {rt/rt) (nl (it/-) (hl (Muck NA pus. v) (Ate. I." (ftl 0.63 017-75110 019-25,00 LT 562 00 558.00 0 280 0.70 0.290 0.50 0.010 0.30 0,400 0.400 5X0 6.64 5.90 2.66 2.36 4.00 Too 3.00 3 00 3EC2 TY3 6 0.054 NA OXBO 0.21 271 0.20 2.61 1.05 YES YES 0.79 YES YTTS 032 YES 004,66.06 605+16,60 553.24 553,00 0,030 0.90 0.129 0.50 01150 0,30 0.107 0.763 5.00 6.14 5.40 4.69 4.12 QOO 1.00 3.00 7 W 3TC -2 Ty3 10 0.0% NA 0X05 a.% 1.16 0,62 112 613 YES YES 0.14 YES 4.00 1.00 19 Dewberry- Dewberry PROJECT: soars Head Connector Road DATE: 11/21/2017 DITCH IDENTIFICATION: 3-1 TO 3-61 DITCH TO STR 1-5I COUNTY: ENGINEER: Ditch Computations LD -les Albemarle HCG / Dewberry Consultants LLC CONNECTOR ROAD Ditch Computations LD_26R 1r� N Ditch G Hvicivaulllu PROJECT: Invert Frm station To5ta'-cn LTUpstrcarn fbwrstrcam Area 1 )acres) C 0.9 Moa I {Maes+ t OS Arca 3 (acres) C 0.3 1W CA Total CA Tt {min} SO yr i Iln/hr) 2yr i (IVhr) 10 yr Q (cis} 2yr a (Cfs) Bottom B (ft) Depth Y M1 Left Slope (HM Right Slope (HM Uning Type Lining Width (ft) n DRch Curve? R,(ftk Ditch Slope Ut)ftk l0Y Depth (ftl low Velocity (ft/sec) 2yr Depth (ftl 2yr Vrlpcily (ft/sec) 1ractive Fottt"C .1 Llning Adeg7 IMaxV1 UrWrkg Free- Capaclty Adeq? board Adeq? IMaxr.'i (ft} 000-0000 DU,,b D1 567 00 551.Ub 0.180 070 0 330 0.50 MID 0.30 0.390 0 390 500 6.64 5.90 2.59 2.30 0.00 1.00 b 00 5 DO LelSA'se 6 0,055 NA 0.022 0.53 1.65 0.51 r F1 0.37 YES YES 0.47 ' • 002+65+00 003+16.00 551.06 559.40 0.90 0.070 050 0.060 0.30 0.053 0.443 5.00 6.54 5.90 2.90 2.57 0.00 1.00 6.00 3.00 E.Istlng 5 0.055 NA 0.033 0.56 2.07 0.53 _ - 056 YES YES 0.44 .1.._ 003+16.00 003+66.00 559.40 557.50 0.063 0.90 0.111 OSO 0.050 0.30 0.073 0.516 5.00 6.44 5.70 3.32 2.94 4.00 1.00 5.00 3.00 Emitting 5 0.055 NA 0.039 0.60 2.31 0.57 . _ - 0.68 YES YES 0.40 i[s 003+6+6X0 004+16.00 $57.50 555.40 0.613 OL90 O -D84 0.50 Ml 0.30 (1.069 0-585 5.00 6.34 $.Go 3.71 3.28 0110 IDD 3.00 3.00 ;-EC-2 Ty; 5 0.050 NA 0.042 0.66 2.82 0.63 2.73 0.82 YES YES 0.34 YES 004+16.06 00446 00 SMAO 553.24 0.022 0.90 O.0T3 0.50 0.060 030 0.071 0-657 500 6.24 5.50 4.10 3.61 0.00 10) 3.00 340 3•EC-2TY3 5 0.050 NA 0.043 1 0.68 1 2.92 4.65 2-113 087 YES YTTS 032 YES 004,66.06 605+16,60 553.24 553,00 0,030 0.90 0.129 0.50 01150 0,30 0.107 0.763 5.00 6.14 5.40 4.69 4.12 QOO 1.00 3.00 7 W 3TC -2 Ty3 10 0.0% NA 0X05 a.% 1.16 0,62 112 613 YES YES 0.14 YES 4.00 1.00 3.00 3.00 34C-2 Ty3 7 0.050 NA 0,022 0.37 1,98 0.35 1.91 651 YES YES 6.63 YES 007440.00 007-90.00 552.60 550.20 0.0112 DAG 0.030 050 0.30 0.017 0.585 5.00 6.54 5.90 .;y i_1- Dewberry Ditch Computations LD_26R 1r� PROJECT: town's Head eannrQp Road COUNTY: Albemarle DATE: 11/21/2017 ENGINEEIL HCG / Dewberry Consultants LLC DMH IDENTIFICATION: 4-1 TO 4-3 ISM. 1-6 OUTFALL) CONNECTOR ROAD Hvdrokev Ditch Hvilraitilics Invert Arra C Arra { Arca C rrxr Total Tc lb yr 2yr low Iyr Bottom Depth left Right Llning Lining n Dt[dI Ditch MY 10 yr 2Yr 2yr Tractive Lining UrWng Free- Capacity Fran Staum To Stowm LT Up4FF Dowrstrcam 1 O.9 2 OS 3 0.3 CA CA i r R 0. B Y Slope Slope Type Width Cwd Slope Depth Veloi ty Dsph Vdodty FgM'r Adeg7 Adeg? board Adeg7 lanes) (aoesk (ntcresk {min} {ItI/hr) IIMAr) (e151 Icfs) (fq [ft} (HM {H/VI fft1 R,(ftk [ir/ftk (ft} (F[hecl If1l [f1lsec) I ' (blaxvk {u4axr,;, 1 (ft} 000-00.00 607-40.6) 56900 552.60 0,240 090 0.530 0.50 6290 0,30 0.569 0.568 5.00 6.64 5.90 3.77 3.35 4.00 1.00 3.00 3.00 34C-2 Ty3 7 0.050 NA 0,022 0.37 1,98 0.35 1.91 651 YES YES 6.63 YES 007440.00 007-90.00 552.60 550.20 0.0112 DAG 0.030 050 0.30 0.017 0.585 5.00 6.54 5.90 3.112 3.39 4.00 TAD 3.00 3.00 3r -EC -2 Ty3 6 0.050 NA 0.049 0.30 2.59 0.28 2A9 0.90 YES YES 0.70 YES 007+90.00 009+25.00 55020 549.20 D.030 D_90 0.025 0.50 0.30 0.022 0.606 5110 6.44 5.70 3.90 3.46 4110 1.D0 3.00 3110 3{{-2 Ty3 7 0.050 NA 0.029 0.35 I.18 0.33 210 0-63 YES YES D.65 YES 41__���Dewberry° Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 (FAX) C) 0. Q 0p O LL1O VJ �O Uc) Q�0 ~ ��� O� �w 00 vv �� Ov~ LL zZ) LL Q) J � 0c) 2i LL J W Ow UO w0z (Dm �o �( Z 2O o Q 01-- o U �LL SEAL - �'�V,p►LT1Y0Ap 11EW S IV Lic. No, 465 1 ,; Ip G SCALE SCALE: 1" = 50' 0 50' 100' No. I DATE I BY I Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE DITCH MAPS AND CALCULATIONS PROJECT NO. 50097555 C9.09 SHEET NO. OF 1 7 - d R F 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WIZ m �oo 0 OO OO c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1" = 50' 0 50' 100' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE CULVERT MAPS AND CALCULATIONS PROJECT NO. 50097555 C901 SHEET NO. OF C FR C L: G 1 7 - d F F DET BASIN DA Post Development 1 year 1 11,380.000 12.000 4.34 DET BASIN DA Post - 2 year 2 16,216.000 12.000 6.23 DET BASIN DA Post- 10 year 10 32,099.000 12.000 12.24 0-1 Post Development 1 year 1 11,358.000 12.100 2.53 0-1 Post - 2 year 2 16,188.000 12.150 3.13 0.1 Post - 10 year 10 32,051.000 12.050 11.25 Impervious Areas - Paved; curbs and storm Post 0.000 0.000 0.000 0.000 545.00 98,000 Det Basin (IN) Development 1 1 11,380.000 12.000 4.34 (N/A) (N/A) 902.000 year Open space (Lawns,parks etc.) - Good condition; 0.0 0.042 0.103 1,491.000 2,458.000 548.00 Post 0.250 0.0 0.0 74.000 grass cover a 75% - Soil C 0.0 Det Basin (OUT) Development 1 1 11,358.000 12.100 2.53 546.68 1,902.000 0.0 year sewers - Soil C 2.23 2.07 1.86 1.67 1.49 Det Basin (IN) Post - 2 year 2 16,216.000 12.000 6.23 (N/A) (N/A) Det Basin (OUT) Post - 2 year 2 16,188.000 12.150 3.13 547.37 3,188.000 Det Basin (IN) Post - 10 year 10 32,099.000 12.000 12.24 (N/A) (N/A) Det Basin (OUT) Post - 10 year 10 32,051.000 12.050 11.25 547.94 4,539.000 Impervious Areas - Paved; curbs and storm 0.0 0.000 0.000 0.000 0.000 545.00 98,000 0.110 0.0 0.0 98.000 sewers - Soil C 0.0 0.027 0.062 902.000 967.000 Open space (Lawns,parks etc.) - Good condition; 0.0 0.042 0.103 1,491.000 2,458.000 548.00 74,000 0.250 0.0 0.0 74.000 grass cover a 75% - Soil C 0.0 0.083 0.215 3,124.000 7,813.000 Impervious Areas - Paved; curbs and storm 98,000 0.420 0.0 0.0 98.000 sewers - Soil C 2.23 2.07 1.86 1.67 1.49 Open space (Lawns,parks etc.) - Good condition; 1.28 1.07 0.92 0.79 0.69 12.750 74,000 1.310 0.0 0.0 74.000 grass cover > 750/n - Sail C 0.38 0.37 0.35 0.34 0.33 Woods - good - Soil C 70.000 0.770 0.0 0.0 70.000 COMPOSITE AREA & WEIGHTED CN ---> (N/A) 2.860 (N/A) (N/A) 77371 544.70 0.0 0.000 0.000 0.000 0.000 545.00 0.0 0.015 0.015 65.000 65.000 546.00 0.0 0.027 0.062 902.000 967.000 547.00 0.0 0.042 0.103 1,491.000 2,458.000 548.00 0.0 0.061 0.154 2,231.000 4,689.000 549.00 0.0 0.083 0.215 3,124.000 7,813.000 Orifice -Area Orifice - 1 Forward Culvert - 1 544.70 549.00 Rectangular Weir Weir - 1 Forward Culvert - 1 547.40 549.00 Culvert -Circular Culvert - 1 Forward TW 544.70 549.00 Tailwater Settings Tailwater 0.06 0.07 (N/A) (N/A) 10.500 0.00 0.00 0.00 0.01 0.01 10.750 0.01 0.01 0.02 0.02 0.02 11.000 0.03 0.03 0.04 0.04 0.05 11.250 0.06 0.06 0.07 0.08 0.09 11.500 0.11 0.12 0.16 0.22 0.34 11.750 0.52 0.74 1.00 1.45 1.83 12.000 2.18 2.41 2.53 2.49 2.38 12.250 2.23 2.07 1.86 1.67 1.49 12.500 1.28 1.07 0.92 0.79 0.69 12.750 0.60 0.51 0.46 0.43 0.40 13.000 0.38 0.37 0.35 0.34 0.33 13.250 0.32 0.31 0.30 0.30 0.29 13.500 0.28 0.28 0.27 0.26 0.26 13.750 0.25 0.24 0.24 0.23 0.23 14.000 0.22 0.22 0.21 0.21 0.21 14.250 0.20 0.20 0.20 0.20 0.19 14.500 0.19 0.19 0.19 0.19 0.19 14.750 0.18 0.18 0.18 0.18 0.18 15.000 0.18 0.17 0.17 0.17 0.17 15.250 0.17 0.17 0.16 0.16 0.16 15.500 0.16 0.16 0.15 0.15 0.15 15.750 0.15 0.15 0.14 0.14 0.14 16.000 0.14 0.14 0.14 0.13 0.13 16.250 0.13 0.13 0.13 0.13 0.13 16.500 0.13 0.13 0.13 0.13 0.13 16.750 0,12 0,12 0.12 0.12 0.12 17.000 0.12 0.12 0.12 0.12 0.12 17.250 0.12 0.12 0.12 0.12 0.12 17.500 0.11 0.11 0.11 0.11 0.11 17.750 0.11 0.11 0.11 0.11 0.11 18.000 0.11 0.11 0.11 0.11 0.11 18.250 0.10 0.10 0.10 0.10 0.10 18.500 0.10 0.10 0.10 0.10 0.10 18.750 0.10 0.10 0.10 0.10 0.10 M000 0.09 0.09 0.09 0.09 0.09 19.250 0.09 0.09 0.09 0.09 0.09 19.500 0.09 0.09 0.09 0.09 0.08 19.750 0.08 0.08 0.08 0.08 0.08 20.000 0.08 0.08 0.08 0.08 0.08 20.250 0.08 0.08 0.08 0.08 0.08 20.500 0.08 0.08 0.08 0.08 0.08 20.750 0.08 0.08 0.08 0.08 0.08 21.000 0.08 0.08 0.08 0.08 0.08 21.250 0.07 0.07 0.07 0.07 0.07 21.500 0.07 0.07 0.07 0.07 0.07 21.750 0.07 0.07 0.07 0,07 0.07 22.000 0.07 0.07 0.07 0.07 0.07 22.250 0.07 0.07 0.07 0.07 0.07 22.500 0.07 0.07 0.07 0.07 0.07 22.750 0.07 0.07 0.07 0.07 0.07 23.000 0.07 0.07 0.07 0.07 0.07 23.250 0.07 0.07 0.07 0.07 0.07 23.500 0.07 0.07 0.07 0.07 0.07 23.750 0.07 0.07 0.07 0.07 0.07 24.000 0.07 (N/A) (N/A) (NIA) (N/A) 9.650 0.00 0.00 0.00 0.00 0.01 9.900 0.01 0.01 0.01 0.01 0.01 10.150 0.02 0,02 0.02 0.02 0.03 10.400 0.03 0.03 0.04 0.04 0.04 10.650 0.05 0.05 0.06 0.06 0.07 10.900 0.08 0.08 0.09 0.10 0.10 11.150 0.11 0.13 0.14 0.15 0.17 11.400 0.18 0.20 0.22 0.25 0.31 11.650 0.42 0.61 0.81 1.10 1.50 11.900 1.93 2.38 2.74 3.00 3.12 12.150 3.13 3.05 2.94 2.80 2.66 12.400 2.51 2.32 2.14 1.94 1.73 12.650 1.54 134 1.13 0.97 0.85 12.900 0.76 0.69 0.62 0.55 0.51 13.150 0.48 0.46 0.44 0.42 0.41 13.400 0.40 0.39 0.38 0.37 0.36 13.650 0.35 0.35 0.34 0.33 0.32 13.900 0.32 0.31 0.30 0.29 0.29 14.150 0.28 0.28 0.27 0.27 0.27 14.400 0.26 0.26 0.26 0.26 0.25 14.650 0.25 0.25 0.25 0.25 0.24 14.900 0.24 0.24 0.24 0.23 0.23 15.150 0.23 0.23 0.22 0.22 0.22 15.400 0.22 0.21 0.21 0.21 0.21 15.650 0.20 0.20 0.20 0.20 0.19 15.900 0.19 0.19 0.19 0.18 0.18 16.150 0.18 0.18 0.18 0.17 0.17 16.400 0.17 0.17 0.17 0.17 0.17 16.650 0.17 0.17 0.17 0.17 0.16 16.900 0.16 0.16 0.16 0.16 0.16 17.150 0.16 0.16 0.16 0.16 0.16 17.400 0.15 0.15 0.15 0.15 0.15 17.650 0.15 0.15 0.15 0.15 0.15 17.900 0.15 0.14 0.14 0.14 0.14 18.150 0.14 0.14 0.14 0.14 0.14 18.400 0.14 0.14 0.13 0.13 0.13 18.650 0.13 0.13 0.13 0.13 0.13 18.900 0.13 0.13 0.13 0.12 0.12 19.150 0.12 0.12 0.12 0.12 0.12 19.400 0.12 0.12 0.12 0.11 0.11 19.650 0.11 0.11 0.11 0.11 0.11 19.900 0.11 0.11 0.11 0.11 0.10 20.150 0.10 0.10 0.10 0.10 0.10 20.400 0.10 0.10 0.10 0.10 0.10 20.650 0.10 0.10 0.10 0.10 0.10 20.900 0.10 0.10 0.10 0.10 0.10 21.150 0.10 0.10 0.10 0.10 0.10 21.400 0.10 0.10 0.10 0.10 0.10 21.650 0.10 0.10 0.10 0.10 0.10 21.900 0.10 0.10 0.10 0.10 0.10 22.150 0.10 0.10 0.10 0.10 0.10 22.400 0.09 0.09 0.09 0.09 0.09 22.650 0.09 0.09 0.09 0.09 0.09 22.900 0.09 0.09 0.09 0.09 0.09 23.150 0.09 0.09 0.09 0.09 0.09 23.400 0.09 0.09 0.09 0.09 0.09 23.650 0.09 0.09 0.09 0.09 0.09 23.900 0.09 0.09 0.09 (N/A) (N/A) 7.600 0.00 0.00 0.00 0.00 0.00 7.850 0.01 0.01 0.01 0.01 0.01 8.100 0.01 0.01 0.02 0.02 0.02 8.350 0.02 0.02 0.03 0.03 0.03 8.600 0.03 0.03 0.04 0.04 0.04 8.850 0.05 0.05 0.05 0.05 0.06 9.100 0.06 0.06 0,07 0.07 0.07 9.350 0.07 0.08 0.08 0.08 0.08 9.600 0.09 0.09 0.09 0.10 0.10 9.850 0.11 0.11 0.12 0.12 0.13 10.100 0.13 0.14 0.15 0.15 0.16 10.350 0.17 0.18 0.19 0.20 0.20 10.600 0.21 0.23 0.24 0.25 0.26 10.850 0.28 0.29 0.31 0.33 0.35 11.100 0.37 0.39 0.41 0.44 0.48 11.350 0.52 0.55 0.60 0.64 0.69 11.600 0.78 0.97 1.29 1.66 2.09 11.850 2.55 3.04 7.96 10.82 11.25 12.100 9.78 7.19 4.71 3.32 3.10 12.350 3.02 2.93 2.82 2.71 2.60 12.600 2.46 2.31 2.16 2.02 1.85 12.850 1.69 1.56 1.45 1.30 1.17 13.100 1.07 0.99 0.93 0.88 0.84 13.350 0.80 0.77 0.75 0.72 0.70 13.600 0.68 0.66 0.63 0.61 0.59 13.850 0.58 0.56 0.55 0.54 0.52 14.100 0.51 0.50 0.49 0.48 0.48 14.350 0.47 0.47 0.46 0.46 0.45 14.600 0.45 0.45 0.44 0.44 0.43 14.850 0.43 0.42 0.42 0.41 0.41 15.100 0.41 0.40 0.40 0.39 0.39 15.350 0.38 0.38 0.37 0.37 0.37 15.600 0.36 0.36 0.35 0.35 0.34 15.850 0.34 0.33 0.33 0.33 0.32 16.100 0.32 0.31 0.31 0.31 0.30 16.350 0.30 0.30 0.30 0.30 0.30 16.600 0.29 0.29 0.29 0.29 0.29 16.850 0.29 0.28 0.28 0.28 0.28 17.100 0.28 0.28 0.28 0.27 0.27 17.350 0.27 0.27 0.27 0.27 0.26 17.600 0.26 0.26 0.26 0.26 0.26 17.850 0.25 0.25 0.25 0.25 0.25 18.100 0.25 0.24 0.24 0.24 0.24 18.350 0.24 0.24 0.23 0.23 0.23 18.600 0.23 0.23 0.23 0.23 0.22 18.850 0.22 0.22 0.22 0.22 0.22 19.100 0.21 0.21 0.21 0.21 0.21 19.350 0.21 0.20 0.20 0.20 0.20 19.600 0.20 0.20 0.19 0.19 0.19 19.850 0.19 0.19 0.19 0.18 0.18 20.100 0.18 0.18 0.18 0.18 0.18 20.350 0.18 0.18 0.18 0.18 0.17 20.600 0.17 0.17 0.17 0.17 0.17 20.850 0.17 0.17 0.17 0.17 0.17 21.100 0.17 0.17 0.17 0.17 0.17 21.350 0.17 0.17 0.17 0.17 0.17 21.600 0.17 0.17 0.17 0.17 0.17 21.850 0.17 0.17 0.17 0.17 0.17 22.100 0.16 0.16 0.16 0.16 0.16 22.350 0.16 0.16 0.16 0.16 0.16 22.600 0.16 0.16 0.16 0.16 0.16 22.850 0.16 0.16 0.16 0.16 0.16 23.100 0.16 0.16 0.16 0.16 0.16 23.350 0.16 0.16 0.16 0.16 0.16 23.600 0.16 0.16 0.15 0.15 0.15 23.850 0.15 0.15 0.15 0.15 (N/A) DewberrycR, Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) C Q �o O LU >- Cf)W O (/)< ADO w 0(j~2 0- 0 U J� z 2i LL J LLJ O w(-)0 0 W Z (D U m U ��Z 2� OC) o O � U LL SCALE: 1" = 50' 0 50' 100' No. DATE BY Descrlptlon REVISIONS DRAWN BY APPROVED BY CHECKED BY nnTi= MARCH 2018 DETENTION BASIN DETAILS PROJECT NO. 50097555 C9.1 1 C C 1 7 A F F 112" MAX' NOTE: HS -20 RATED 1'_II IUllll CASTING SHALL BE ADA COMPLIANT TOP WITH 1/2" OPENINGS PRECAST CONCRETE DRAINAGE STRUCTURE TOP WEIR WA' INV. EI. 547.4 INLET SHAPING PER VDOT IS -1 19 3/4"' 18" MIN.' SECTION A A YARD INLET GRATE DETAIL INLET GRATE FRAME AND COVER. SEE DETAIL THIS SHEET. BOLT FRAME TO STRUCTURE a 18" SQUARE ADA GRATE (SEE DETAIL) 4' MA FLEXIBLE BOOT CONNECTOR B � a a STORM PIPE —� MIN. 6" BEDDING WITH X68 STONE N.T.S. x2' INSIDE DIMENSION' SECTION VIEW TOP VIEW NOTES: 1. PRECAST CONCRETE SHALL HAVE A MINIMUM STRENGTH OF 4,000 PSI. 2. ALL JOINTS, LIFT HOLES, INLETS, AND OUTLETS SHALL BE SEALED WITH NON—SHRINK GROUT INSIDE AND OUT. THE EXTERIOR SURFACE OF THE MANHOLE SHALL BE WATERPROOFED USING BITUMASPC WATERPROOFING. SEE MANHOLE JOINT DETAIL. 3. MINIMUM ELEVATION DIFFERENCE ACROSS THE MANHOLE FROM INLET TO OUTLET SHALL BE 0.1 FEET FOR STRAIGHT RUNS AND 0.25 FEET FOR CHANGES IN DIRECTION. 4. PRECAST STRUCTURE SHALL BE DESIGNED IN ACCORDANCE WITH ASTM C890 FOR HS -20 LOADING AND SHALL CONFORM TO ASTM 478. 5. NO CONCRETE SHALL BE VISIBLE AT THE GROUND SURFACE. 6. PROVIDE INLET SHAPING PER THE VDOT STANDARD METHOD OF SHAPING MANHOLE AND INLET INVERTS DETAIL (IS -1). YARD INLET DETAIL CONCRETE FOOTER WATEf. ORIFICE - 1.0' x 6" PLAN VIEW TOP WEIR V WATER QUANTITY f~—I� EL. 547.40' ORIFICE - 1.0' x 6" INV. FL 544.70' H+3" METAL DEBRIS RACK NOT SHOWN - SEE VDOT ROA[ & BRIDGE STD. SWM -DR PAGE 114.05 L WATER QUHiv SEE VDOT STANDARD EW -1 ENDWALL FOR ORIFICE - 1.0' x 6" NV. EI. 544.70 ENDWALL FOR DIMENSION AND NOTES FRONT VIEW N.T.S. C I �7, A-7 A n SEE VDOT STANDARD EW -1 ENDWALL FOR ENDWALL FOR DIMENSION AND NOTES NOTE. CAST -IN-PLACE CONCRETE SHALL BE CLASS A3. REINFORCING STEEL SHALL BE GRADE 60. J U SIDE VIEW MODIFIED EW -1 WITH WEIR WALL DETAIL FLOW ONCRETE RADLE REQ'D N.T.S. FIGURE A-6 SPEED TABLE / RAISED INTERSECTION R;Drrip Up A, Tabl M Ramp Up A _ as wf •I A, Tabl 1 Ramp Up A _ 11 _p Cross section AA Flat "table" area 22'-0" NOTES: 1. The flat "table" area length of 11 feet accommodates the typical passenger car wheelbase entirely on the top, but can be extended to accommodate other vehicles if desired. A length of 20 feet accommodates the typical single unit truck (AASHTO SU -30). 2. The "Ramp -up" transition shows an approximate slope of 4.2% (rise of 3" over 6' run). 3. A raised intersection would mimic the speed table design for each approach where the "ramp -up" occurs prior to entering the intersection and the flat table area encompasses the entire area of intersection for the approaching streets and therefore in most cases will exceed 11 feet. 4. Leave gutter pan open to facilitate drainage. 5. A 12" wide, 1" depth grind around the perimeter of the device is recommended in order to allow the surface course to be keyed into the pavement for a more durable application, particularly for snow plowing. 6. Per the 2009 MUTCD: i. Section 3B.25 —speed hump (table) markings are not required but if used they must comply with options per Section 3B.25. ii. Section 2C.29 - warning sign W 17-1 is optional but if used, should include the advisory speed plaque (W13-1) and; the sign may use "Speed Bump" instead of "Speed Hump." 59Page SPEED TABLE DETAIL SOURCE: VDOT TRAFFIC CALMING GUIDE FOR NEIGHBORHOOD STREETS, REV. 11/17 VDOT CLASS 1 RIPRAP AS REQUIRED BY 2' GRAVEL DIAPHRAGM CONCENTRATED FLOW LEVELSPREADER FROM PIPE VDOT #8 STONE CLEAN WASHED LENGTH = 19 FT � 3:1 2' GEOTEXTILE FILTER FABRIC 4' GRAVEL FLOW SPREADER DETAIL N.T.S. N.T.S. Dewberry' Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) �w0 U)<I­ �0 U� 00 c) c) LLI �� 0U~ LLQ Z� ��U J� pU J W OOw UO w0z 120 o0 HOZ �0 0 0 0� o U 11� LL SEAL SCALE gALT1Y pAD O- TT EW Lic. No, 465 1 3 ���� w Ai.E�G� No. DATE BY Descrlptlon REVISIONS DRAWN BY APPROVED BY CHECKED BY DATE TITLE 0 TMR DMK MCT MARCH 2018 CONSTRUCTION DETAILS PROJECT NO. 50097555 C10.01 SHEET NO. OF 41__t��Dewberry° C Dewberry Engineers Inc. 4805 LAKE BROOK DRIVE SUITE 200 GLEN ALLEN, VA 23060 804.290.7957 (PHONE) 804.290.7928 ( FAX) Fp C)ry Q oo O TWO UQ � ��� �O Uc) <�� O� �w 00 vv O�� v~ �� z� �LL(� J� Ov J W OOw UO WIZ m �oo 0 OO OO c:) U r LL SEAL -�,p►LT1YoA �O ZS i TT EW . Ap Lic. No. 465 1 Ai.E�G� C SCALE SCALE: 1" = 20' now 0 20' 40' IV L No. DATE BY Descrlptlon REVISIONS DRAWN BY TMR APPROVED BY DMK CHECKED BY MCT DATE MARCH 2018 TITLE LANDSCAPING PROJECT NO. 50097555 C 11 0 1 ■ SHEET NO. OF